You are on page 1of 1

#10

1A-6

#10

#10

#10
1A-11

1A-11

1A-11

1A-11

DEPOSITO

#10

A=4.4 [m^2]

1A-11

1A-11
3A-1

#10
1A-3

PARQUEADERO
1A-6

3A-1
Gf
1A-3

1A-3

1A-3

1A-2

1A-2

1A-2

CUARTO
DE
BOMBAS

1A-2
1A-1

1A-6

1A-1

1A-11

3A-1

#10

1A-6

3A-9

1A-11

#10

#10

3A-1

3A-1

3A-7
E

CUBIERTO

1A-3

3A-5

AUDITORIO

TARIMA

3A-4
#10

#10

CAFETERIA

#10

A=226.8 [m^2]
3A-8
Gf
3A-3

1A-6

3#10 F
2#10 N
1#10 T

1A-11

1A-1

1A-1
1A-6

1A-6

1A-3

1A-3

1A-3

1A-2

1A-2

3#10 F
2#10 N
1#10 T
3A-1

3A-1

1A-2

1A-2
3#12 F
1#12 N
1#12 T

1A-3

1#12 F
1#12 N
1#12 T

1A-6

Gf
4#10 F
3A-6
2#10 N
1#12 F
4#10 F
1#12 N
2#10 N
1#10 T
1#12 T TC 3A 1#10 T

3A-2

1A-6
#4
#10
#12

#6

CORREDOR CUBIERTO A1

HACIA
TG

A=48.8 [m^2]
1A-5

1A-5
1A-4

1A-9

1A-7

1A-9

1A-9

HACIA
TG

#6

#8
1A-7

1A-7

1A-9

1A-4

1A-7

ENFERMERIA

A=3.4 [m^2]

TABLERO GENERAL
DE DISTRIBUCION

CARCAMO

ODONTOLOGIA

TRAFO

1A-7
1A-4
1A-4
1A-4

1A-7

1A-4

1A-7

1A-4

1A-7

1A-4
1A-4

1A-7

CORREDOR CUBIERTO A1

1A-7
2#12 F
1#12 N
1#12 T

TC 1A

1A-4

PORTERIA
A=7.4 [m^2]

ZONA
DESCUBIERTA

1A-8

Hacia

2#12 F
1#12 N
1#12 T

2A-9

HACIA
TG

2A-3

2A-9

2A-9

2A-3

2A-3

2A-3

Desde
2-Piso

2A-3

2A-3

2A-3

2A-5

3#12 F
2#12 N
1#12 T

Hacia
2-Piso

3B-7

1A-1

1A-1

ZONA
DESCUBIERTA

2A-1

2A-1

#2

2A-1

2A-1

2A-5

HACIA
SOTANO

#4
TC 2A
A.A.

2A-1

2A-10,12

2A-4

Hacia

2A-4

2A-4

2A-7

2A-7

2A-4

2A-4

2A-4

2A-4

2A-1

2A-4

2A-4

2A-1

2A-6

2A-1

2A-5

1A-5
2A-7

2A-7

2A-7

2A-7

2A-6

2A-7

2A-6

2A-6

A.A. 2A-14,15

2A-5
2A-6

LABORATORIO DE COMERCIALES

2A-5

A=67 [m^2]
2A-1

2A-1

2A-6

2A-6

2A-1

2A-8

2A-1

2A-8

2A-5

2A-5

2A-8

2A-6

2A-8

1A-5

1A-5

HACIA
TC 2A

2A-2
2A-2

2A-2

2A-2

2A-2

2A-2

2A-2

2A-2

SOTANO

PRESENTA

PROPIETARIO:

CONDUCTOR FASE

EN DONDE NO SEA INDICADO EL DUCTO

CONDUCTOR NEUTRO

ANCLAJES CADA METRO, EL ANCLAJE


CONSISTE EN PLATINA DE ALUMINIO Y 2
CHASOS). Y LA TUBERIA EXISTENTE QUE
NO SE INDIQUE ES PVC 1/2''

CONDUCTOR DE PUESTA A
TIERRA

TODOS LOS CONDUCTORES SON EN THW DE


Cu
DESDE EL TABLERO GENERAL (TG) AL
TABLERO DE DISTRIBUCION CADA TUBERIA
ALOJARA SU RESPECTIVA ACOMETIDA.

DESDE EL TRANSFORMADOR HASTA EL


TABLERO GENERAL (TG) LOS CONDUCTORES
SON ALOJADOS POR UN CARCAMO.

PROYECTO

DIRECCION

CONTIENE

Fecha
A.A.

Gf

AUNQUE NO SE INDICAN, TODAS LAS


CANALIZACIONES LLEVAN UN CONDUCTOR
DE CONTINUIDAD DE TIERRA. ESTOS SON
DESNUDOS , CALIBRE #12 AWG Cu

REVISO

LOS CONDUCTORES SIN INDICAR


CORRESPONDEN A CABLE THW #12 DE Cu .

PLANO

1 DE 6

Escala
APROBACION ESSA

APROBO
E

MARZO 2012

DIBUJO

ESTAN RESALTADOS EN COLOR ROJO.

NUMERO

2A-5