Professional Documents
Culture Documents
A.2. Calculo de Minimo Espesor
A.2. Calculo de Minimo Espesor
OF POWER BOILERS
Donde: D= outside diameter of cylinder e= thickness factor for expanded tube ends (see PG-27.4, Note 4) P= maximum allowable working pressure (see PG-21) S= maximum allowable stress value at the design temperature of the metal, as listed in the tables specified in PG-23 (see PG-27.4, Note 2) t= minimum required thickness (see PG-27.4, Note 7) Temperatura: P= D= S= e= t= 500F 4,28 63,5 91,9 0 1,7609 260C Mpa mm Mpa 620 psi 2.5 in a T<=300C TABLA 1A ASME SECCION II PARTE D