CONT.No.

: DATE : BY : CHECKED : DATE : SHEET No:

56115002 7-May-13 R.C.S R.C.S 16-7-01 1

FLOW IN A CHANNEL - MANNING FORMULA Project: Subject: PROJECT SAMPLE CHANNEL FLOW. GROUND FLOOR BLDG

Flow in concrete channel. Flow required Q = 0.020 m3/s

Coefficient of surface roughness n = Slope of channel S = 1 Vertically

0.017 100 Horizontal.

1 %

Depth of flow d = Width of channel required b = Area of flow in channel A =b*d Wetted perimeter P =b+2d 0.030 sq.m 0.70 m

0.05 m 0.60 m R= 0.043 m

Manning Formula Q = 1 / n* A*(R)^2/3*S^1/2 Discharge Velocity Q = V = 0.0216 m3/s 0.72 m/s (MIN 0.8 , MAX 3 M/S)