You are on page 1of 12

Proiectarea fundatiilor izolate

A. Proiectarea fundatiilor rigide, alcatuite din bloc de beton simplu si cuzinet din
beton armat pentru un stalp central si un stalp marginal
Stalp central C2:
-adancimea de fundare:
Df. := 1.0 m

Fortele axiale si momentele incovoietoare, evaluate prin analiza structurala:


Nasc1 := 768kN

Masc1 := 87kN m

Nfc1 := 1.05 Nasc1 = 806.4 kN

Mfc1 := 1.05 Masc1 = 91.35 kN m

Determinarea presiunii Ppl


Pefmax Ppl

:= 1.2

Ppl = ml B N1 + q N2 + c N3

ml := 1.4

:= 18.5

kN
3

m
kN
qc1 := Df. = 18.5
2
m

N1 := 0.98

N2 := 4.93

N3 := 7.4

c := 30kPa

:= 1.2

Stabilirea dimensiunilor fundatiei:


n=

ls
L
=
B
bs

Pefmax =

n = ( 1.1 .. 1.3 )

L = 1.2 B

Nfc1
6 ec1
1 +

Bc1 Lc1
Lc1

Mfc1
ec1 :=
= 11.328 cm
Nfc1

Nfc1
6 ec1

1 +
= ml Bc1 N1 + qc1 N2 + c N3
Bc1 1.2 Bc1
1.2 Bc1

Nfc1
6 ec1

1 +
= ml Bc1 N1 + qc1 N2 + c N3
Bc1 1.2 Bc1
1.2 Bc1

Bc1 = 1.305m

Pentru n := 1.2

Lc1 := 1.2 1.305m = 1.6 m

Adopt ca valori: Bc1 := 1.4 m Lc1 := 1.6 m


Verificare
kN
Pplc1 := ml Bc1 N1 + qc1 N2 + c N3 = 474.022
2
m

Pplc1 = 568.826

kN
2

Pefmaxc1 :=

Nfc1
6 ec1
kN
1 +
= 512.93 2
Bc1 Lc1
Lc1

Pefmax Ppl

Pefminc1 :=

Nfc1
6 ec1
kN
1
= 207.07 2
Lc1
Bc1 Lc1

Pefmin Ppl 0

Pe verticala avem urmatoarele dimensiuni:


hc 30cm

lcc1
Lc1

= 0.5

lcc1 := 0.5 Lc1 = 80 cm

lcc1
bcc1

Lc1
Bc1

bcc1 :=

lcc1 Bc1
Lc1

= 70 cm

l0c1 := 30cm

tan ( ) 1

tan ( ) = f Pefmax , C8.10

Pefmaxc1 = 512.93

kN

C8/10

tan ( ) = 1.5

m
tan ( ) =

Hc1

Hc1 := 1.5

Lc1 l cc1

Lc1 lcc1

= 60 cm

Hc1 = 0.6 m

H 70cm

1 treapta

tan ( ) =

hcc1
l0c1

hcc1 := l0c1 = 30 cm l2c1 :=

= 1

Lc1 lcc1
2

= 40 cm

l1c1 :=

lcc1 l2c1
2

= 20 cm

Adopt ca valori pentru fundatie:

lcc1 = 80 cm

Hc1 = 0.6 m

hcc1 = 0.3 m

l1c1 = 0.2 m

l2c1 = 0.4 m

bcc1 = 0.7 m

l0c1 = 0.3 m

400

+0.60

800

300

200

1400

Bc1 = 1.4 m Lc1 = 1.6 m

300

600

800

0.00
1600

800

400

1600

I.Verificarea terenului de fundare la SLD


ef adm

adm := 8 cm

-Metoda insumarii pe strat elementare(L. Hooke)


= E

= ef

M2_3.I := 62.5

daN
2

ef =

M2_3.II := 66.667

cm

M0 = f Ic , e

M0 := 1.1

daN
2

cm

kN
EI := M2_3.I M0 = 6875
2
m
z = o Pnet

Ei = M2_3 M0

kN
EII := M2_3.II M0 = 7333.37
2
m

L1 Z
o = f
,

B
B1
1

kN
Pnetc1 := Pefc1 Df = 340.575
2
m

Pnetc1 = Pefc1 Df Pefc1 :=

hi 0.4 B1

Pefmaxc1 + Pefminc1

hi := 0.4 Bc1 = 0.56 m

= 360

kN
2

Se calculeaza pana la limita zonei active

z(m)
0

1.00

o = zi
n

s = 1000mm 0

(KN/m) m=L/B z/B

18.5
1.14
0

z.5=3.00

0.60

Esi

z = Hi

EI = 6875

kN
2

EII = 7333.37

hi := 0.6 m

kN
2

z=*Pn H.i
0.000

0.87

0 := 0.85

zimed hi

i =1

0.60

b
z.4=2.40

z.3=1.80

z.1=0.60

a
z.2=1.20

H.1=1.6

H.2=2.20

H.3=2.80

z 0.2 z

296.300

1.60

0.2gz

gz=i*H.i

z med

29.6

5.92

0.6

18.5

1.14 0.375

148.150

1.2

18.5

1.14

0.75

0.73

248.620

2.20

40.7

8.14

272.460

1.8

18.5

1.14 1.125

0.48

163.476

2.80

51.8

10.36

206.048

2.4

18.5

1.14

1.5

0.32

108.984

3.40

62.9

12.58

136.230

18.5

1.14 1.875

0.27

91.955

4.00

74

14.8

100.470

3.6

18.5

1.14

0.19

64.709

4.60

85.1

17.02

78.332

4.2

19.2

1.14 2.625

0.1

34.058

5.20

99.84

19.968

49.383

4.8
5.4
6
6.6

19.2
19.2
19.2
19.2

1.14
3
1.14 3.375
1.14 3.75
1.14 4.125

0.06
0.04
0.03
0.03

20.435
13.623
10.217
10.217

5.80
6.40
7.00
7.60

111.36
122.88
134.4
145.92

22.272
24.576
26.88
29.184

27.246
17.029
11.920
10.217

2.25

Se observa ca inegalitatea z<0.2*z este indeplinita la cota -4.8 m sub talpa


fundatiei cu Z0=4.8m
z1med := 148.15

kN

z2med := 272.46

m
z5med := 100.470

z3med := 206.048

kN
2

z6med := 78.332

zmed1 :=

kN

kN
2

kN
2

z7med := 49.383

kN
2

z4med := 136.23

kN
2

m
z8med := 27.246

kN
2

z1med hi + z2med hi + z3med hi + z4med hi + z5med hi + z6med hi + z7med hi


EI

zmed1 = 8.649 cm
z8med hi
zmed2 :=
= 0.223 cm
EII

ef := 0 zmed1 + zmed2 = 7.541 cm

ef = 7.541 max = 8 cm

II.Verificarea terenului de fundare la starea limita de capacitate portanta


Nsc1 := 0.75 Nfc1 = 604.8 kN
Msc1
ec12 :=
= 22.656 cm
Nsc1

L11c1 := Lc1 2.ec12 = 1.147 m

B11c1 := Bc1 = 1.4 m

mc := 0.9

Pcr = mc B1 N + q Nq q + c Nc c

Pefmed. mc Pcr
N := 6.3

Msc1 := 1.5 Mfc1 = 137.025 kN m

Nq := 13.9

B11c1
B11c1
:= 1 0.4
= 0.512 q := 1 + 0.3
= 1.366
L11c1
L11c1

Nc := 24.8

B11c1
c := 1 + 0.3
= 1.366
L11c1
kN
Pcr := mc B11c1 N + q Nq q + c Nc c = 1312.989
2
m
kN
kN
Pefmed = 376.676
mc Pcr = 1312.989
2
2
m
m

Pefmed. :=

Nsc1
L11c1 B11c1

III.Armarea cuzinetului
l.c
l.x

P.m ed

l.s

b.s
l.y

h.c

b.c

l.1

l.c

P.c2
P.c1

max = 10 mm distanta dintre bare 100...250mm


Pc1 , Pc2 =

Pc2c1 :=

N
bc1 lc1
Nfc1

bcc1 lcc1

Pcmedc1 :=

6M
bc1 lc1
6Mfc1

Pcoc1 := Pc2c1 +

= 216.563

= 1440

Nfc1
bcc1 lcc1

6Mfc1
2

bcc1 lcc1

kN
2

bcc1 lcc1

Pc1c1 + Pc2c1
2

Pc1c1 :=

kN
2

(Pc1c1 Pc2c1) (lcc1 l1c1)


lcc1

= 2051.719

kN
2

= 2663.438

kN
2

= 376.676

kN
2

Calculul momentelor incovoietoare :


2
2

l1c1
l1c1
=
Mxc1 := bcc1 Pcoc1
+ ( Pc1c1 Pcoc1)
2
3

2
P
cmedc1 bcc1

Myc1 := lcc1
=
2

34.433 kN m

282.24 kN m

Armarea cuzinetului
Dupa directia x:
Clasa de beton este C20/25:
cc.. := 1 c. := 1.5

fck. := 20

mm

fck.
N
fcd.. := cc.
= 13.333
2
c
mm

Am ales otelul beton marca PC-52, avand urmatoarele caracteristici:


N

fyk.. := 335

mm

d0x1 := hcc1 2.5 cm

x1 := 1

10mm
2

1 2 = 0.039

34.433

:=

10mm = 26 cm

= 0.038

1 0.26 13.33333 10

0.038 < lim = 0.403

fcd..
2
Asx1 := 0.039 1 m d0x1
= 4 cm
fyk..

Aleg 412 la distanta 200 mm A.s=4.520cm2 pentru: lcc1 = 0.8 m


Dupa directia y:
d0y1 := hcc1 2.5 cm

y1 := 1

10mm
2

1 2 = 0.352

282.24

:=

= 27 cm

1 0.27 13.33333 10

fcd..
Asy1 := 0.352 1 m d0y1
fyk..

Aleg 725 la distanta 100 mm A.s=34.37cm2


pentru:

= 0.29 0.29 < lim = 0.403


2

Asy1 = 37.827 cm

bcc1 = 0.7 m

Stalp marginal B1:


-adancimea de fundare:
Df. = 1 m

Fortele axiale si momentele incovoietoare, evaluate prin analiza structurala:


Nasb1 := 374kN

Masb1 := 44kN m

Nfb1 := 1.05 Nasb1 = 392.7 kN

Mfb1 := 1.05 Masb1 = 46.2 kN m

Determinarea presiunii Ppl


Pefmax Ppl

:= 1.2
kN

qb1 := Df. = 18.5


2
m

Ppl = ml B N1 + q N2 + c N3

ml. := 1.4

:= 18.5

kN
3

m
N1. := 0.98

N2. := 4.93

N3. := 7.4

c := 30kPa

Stabilirea dimensiunilor fundatiei:


n=

ls

L
B

Pefmax =

n = ( 1.1 .. 1.3 )

bs

Nb1
Bb1 Lb1

1 +

Nfb1
Bb1 1.2 Bb1

1 +

Mfb1
eb1 :=
= 11.765 cm
Nfb1

L = 1.2 B

6 eb1

Nfb1

Lb1

Bb1 1.2 Bb1

1 +

= ml. ( Bb1 N1. + qb1 N2. + c N3.)


1.2 Bb1

6 eb1

= ml. ( Bb1 N1. + qb1 N2. + c N3. )


1.2 Bb1

6 eb1

Bb1 = 1 m

Pentru n := 1.2
L. := 1.2 1 m = 1.2 m
Adopt ca valori: Bb1 := 1m Lb1 := 1.2 m

I.Verificare SLD
kN
kN
Pplb1 := ml Bb1 N1 + qb1 N2 + c N3 = 463.869
Pplb1 = 556.643
2
2
m
m
Nfb1
6 eb1
kN
Pefmax Ppl
Pefmaxb1 :=
1 +
= 519.75 2
Lb1
Bb1 Lb1
m

Nfb1

Pefminb1 :=

Bb1 Lb1

6 eb1

=
Lb1

kN

134.75

Pefmin Ppl 0

Pe verticala avem urmatoarele dimensiuni:


lcb1
Lb1
lcb1 := 0.5 Lb1 = 60 cm
=
= 0.5
bcb1
Bb1
Lb1
l0b1 := 30cm

lcb1

hc 30cm
tan ( ) 1

tan ( ) = f Pefmax , C8.10

Pefmaxb1 = 519.75

kN
2

bcb1 :=

C8/10

lcb1 Bb1
Lb1

= 50 cm

tan ( ) = 1.5

m
tan ( ) =

Hb1 := 1.5

L lc

Lb1 lcb1
2

= 45 cm

1 treapta

H 70cm

tan ( ) =

hc
l0

hcb1 := l0b1 = 30 cm l2b1 :=

= 1

Lb1 lcb1
2

= 30 cm

l1b1 :=

lcb1 l2b1
2

= 15 cm

Adopt ca valori pentru fundatie:


Bb1 = 1 m
lcb1 = 60 cm

Lb1 = 1.2 m

Hb1 = 0.45 m

hcb1 = 0.3 m l1b1 = 0.15 m l2b1 = 0.3 m

l0b1 = 0.3 m

bcb1 = 0.5 m

II.Verificarea terenului de fundare la starea limita de capacitate portanta


Nsb1 := 0.75 Nfb1 = 294.525 kN

Msb1 := 1.5 Mfb1 = 69.3 kN m

Msb1
e2b1 :=
= 23.529 cm L11b1 := Lb1 2.e2b1 = 0.729 m
Nsb1
Pefmed. mc Pcr

B11b1 := Bb1 = 1 m

Pcr = mc B11b1 N + q Nq q + c Nc c

mc := 0.9

N = 6.3

Nq = 13.9

B11b1
b1 := 1 0.4
= 0.452
L11b1

Nc = 24.8

B11b1
qb1 := 1 + 0.3
= 1.411
L11b1

B11b1
cb1 := 1 + 0.3
= 1.411
L11b1
kN
Pcrb1 := mc B11b1 N b1 + qb1 Nq qb1 + c Nc cb1 = 1318.994
2
m

Pefmed2 = 403.784

kN

kN
mc Pcr2 = 1318.994
2
2
m
m

Pefmedb1 :=

Nsb1
kN
= 403.784
2
L11b1 B11b1
m

III.Armarea cuzinetului
max = 10 mm distanta dintre bare 100...250mm
l.c
l.x

P.med

l.s

l.y

h.c

b.c

b.s

l.1

l.c

P.c2
P.c1
Pc1 , Pc2 =

Pc1b1 :=

6M
N
+
2
bc lc
bc lc

Nfb1
+
bcb1 lcb1

Pcmedb1 :=

6Mfb1
bcb1 lcb1

Pc1b1 + Pc2b1
2

= 2849

= 1309

kN
2

Pc2b1 :=

m
kN
2

Nfb1

bcb1 lcb1

Pcob1 := Pc2b1 +

Calculul momentelor incovoietoare :

Armarea cuzinetului
Dupa directia x:

bcb1 lcb1

= 231

kN

14.582 kN m

lcb1

(Pc1b1 Pc2b1) (lcb1 l1b1)

2
2

l1b1
l1b1
=
Mxb1 := bcb1 Pcob1
+ (Pc1b1 Pcob1)
2
3

2
P
bcb1
cmedb1
= 98.175 kN m
Myb1 := lcb1
2

6Mfb1

= 2079

kN
2

Clasa de beton este C20/25:


cc... := 1 c.. := 1.5 fck.. := 20

fck.
N
fcd... := cc.
= 13.333
2
c
mm

N
2

mm

Am ales otelul beton marca PC-52, avand urmatoarele caracteristici:


d0x2 := hcb1 2.5 cm

x2 := 1

10mm
2

. :=

10mm = 26 cm

fyk... := 335

N
2

mm

14.582
2

= 0.016

1 0.26 13.33333 10

0.016 < lim = 0.403

fcd..
2
Asxb1 := 0.016 1 m d0x2
= 1.7 cm
fyk..

1 2 . = 0.016

Aleg 310 la distanta 200 mm A.s=2.350cm2 pentru lungimea pentru: lcb1 = 0.6 m
Dupa directia y:
d0y2 := hcb1 2.5 cm

y2 := 1

10mm
2

.. :=

= 27 cm

98.175
2

1 0.27 13.33333 10

1 2 .. = 0.107 Asy2 := 0.107 1 m d0y2

fcd..
fyk..

= 0.1010.101 < lim = 0.403

Asy2 = 11.499 cm

Aleg 518 la distanta 100 mm A.s=12.70 cm2 pentru:


bcb1 = 0.5 m
Calculul lungimii de ancoraj:
ea := 6 cm

lcb1 = 0.6 m

Ta := Pc2b1 ea lcb1 = 415.8 daN


2

Aa :=

415.8daN
3350

Ta = Aa fyk

= 0.124 cm

daN
2

Rezulta armatura 110 cu


A.sef=0.785cm2

cm

B. Proiectarea fundatiilor rigide, alcatuite din beton armat monolit sub forma de
obelisc, pentru un stalp de rost si un stalp de colt.
Stalp de colt G9:
-adancimea de fundare:
Df. = 1 m

Fortele axiale si momentele incovoietoare, evaluate prin analiza structurala:


Nasg9 := 166kN

Masg9 := 60kN m

Nfg9. := 1.05 Nasg9 = 174.3 kN Mfg9. := 1.05 Masg9 = 63 kN m


Nfg9 := Nfg9. ( 1 + 0.007 20) = 198.702 kN

Mfg9 := Mfg9. ( 1 + 0.007 20) = 71.82 kN m

Determinarea presiunii Ppl


Pefmax Ppl

:= 1.2
kN

qg9 := Df. = 18.5


2
m

Ppl = ml B N1 + q N2 + c N3

ml = 1.4

ls

L
B

bs

kN
3

m
N1 = 0.98

N2 = 4.93

N3 = 7.4

c = 30 kPa

Stabilirea dimensiunilor fundatiei:


n=

= 18.5

n = ( 1.1 .. 1.3 )

L = 1.2 B

Mfb1
eg9 :=
= 11.765 cm
Nfb1

Pefmax =

Nb1
Bb1 Lb1

1 +

6 eb1

Nfb1

Lb1

Bb1 1.2 Bb1

1 +

= ml. ( Bb1 N1. + qb1 N2. + c N3. )


1.2 Bb1

6 eb1

Bg9 = 1 m
Pentru n = 1.2
L.. := 1.2 1 m = 1.2 m
Adopt ca valori: Bg9 := 1m
Lg9 := 1.2 m

I.Verificare SLD
kN
kN
Pplg9 := ml Bg9 N1 + qg9 N2 + c N3 = 463.869
Pplg9 = 556.643
2
2
m
m
6 eg9
Nfg9
kN P
efmax Ppl
Pefmaxg9 :=
1 +
= 262.988 2
Lg9
Bg9 Lg9

Pefming9 :=
Hg9
Lg9

Nfg9
Bg9 Lg9

6 eg9

=
Lg9

= f Pfmax , verificare

68.182

kN

Pefmin Ppl 0

Hg9 := 0.3 Lg9 = 0.36 m

H1g9 := Hg9 = 0.18 m


2

l1g9 := 40cm

II.Verificarea terenului de fundare la starea limita de capacitate portanta


Nsg9 := 0.75 Nfg9 = 149.027 kN

Msg9 := 1.5 Mfg9 = 107.73 kN m

Pcr = mc B11g9 N + q Nq q + c Nc c
Bg9
Bg9
N = 6.3 Nq = 13.9
Nc = 24.8
g9 := 1 0.4
= 0.667
qg9 := 1 + 0.3
= 1.25
Lg9
Lg9
Bg9
cg9 := 1 + 0.3
= 1.25
Lg9
Pefmed. mc Pcr

kN
Pcrg9 := mc Bg9 N g9 + qg9 Nq qg9 + c Nc cg9 = 1196.224
2
m
Nsg9
kN
kN
kN
Pefmedg9 :=
= 124.189
Pefmedg9 = 124.189
mc Pcrg9 = 1196.224
2
2
2
Lg9 Bg9
m
m
m

III.Armarea cuzinetului
max = 10 mm distanta dintre bare 100...250mm
Y
Y

300
250

0.00

400
400
500
1200

400
350

400
1200

400

180180
360

+0.36

180180
360

400
500
1000

+0.36

0.00

300

400
1000

300

Pcmedg9 :=

Pefmaxg9 + Pefming9
2

Pcog9 := Pefming9 +

= 165.585

kN
2

(Pefmaxg9 Pefming9) (Lg9 l1g9)


Lg9

= 198.053

kN
2

Calculul momentelor incovoietoare :


2
2

l1g9
l1g9
=
Mxg9 := Bg9 Pcog9
+ ( Pefmaxg9 Pcog9)
2
3

2
P
Bg9
cmedg9
=
Myg9 := Lg9
2

19.307 kN m

99.351 kN m

Armarea cuzinetului
Dupa directia x:
X

P.efmed

P.efmed
P.efmax

P.efmin

Clasa de beton este C20/25:


cc = 1

c = 1.5

fck. = 20

fcd.. = 13.333

mm

mm

Am ales otelul beton marca PC-52, avand urmatoarele caracteristici:

fyk = 335

N
2

mm

d0x3 := Hg9 2.5 cm

x3 := 1

10mm
2

10mm = 32 cm

... :=

1 2 ... = 0.014 Asxg9 := 0.014 1m d0x3

19.307
2

1 0.32 13.33333 10

= 0.014

0.014 < lim = 0.403

fcd..
2
= 1.8 cm
fyk..

Aleg 610 la distanta 200 mm A.s=4.710cm2 pentru lungimea de:

Lg9 = 1.2 m

Dupa directia y:
d0y3 := Hg9 2.5 cm

y3 := 1

10mm
2

= 33 cm

1 2 .... = 0.071

.... :=

99.351
2

1 0.33 13.33333 10

fcd..
Asyg9 := 0.071 1m d0y2
fyk..

= 0.068 0.068 < lim = 0.403

Asyg9 = 7.63 cm

Aleg 814 la distanta 125 mm A.s=12.32 cm2 pentru lungimea de:Bg9 = 1 m

Stalp de rost D6':


-adancimea de fundare:
Df. = 1 m

Fortele axiale si momentele incovoietoare, evaluate prin analiza structurala:


Nasd6 := 225kN

Masd6 := 32kN m

Nfd6. := 1.05 Nasd6 = 236.25 kN

Mfd6. := 1.05 Masd6 = 33.6 kN m

Nfd6 := Nfd6. ( 0.95 + 0.008 20) = 262.237 kN

Mfd6 := Mfd6. ( 0.95 + 0.008 20) = 37.296 kN m

Determinarea presiunii Ppl


Pefmax Ppl

= 1.2

Ppl = ml B N1 + q N2 + c N3

= 18.5

ml = 1.4

kN
3

m
kN
qd6 := Df. = 18.5
2
m

N1 = 0.98

N2 = 4.93

N3 = 7.4

c = 30 kPa

Stabilirea dimensiunilor fundatiei:


e=

M
2
= bs = B = 2 bs
3
N

Pefmax =

Nb1
Bb1 Lb1

1 +

e=

6 eb1

Mfd6
bs := 40cm ed6 :=
= 14.222 cm
Nfd6

Nfb1
6 eb1

1 +
= ml. Bb1 N1. + qb1 N2. + c N3.
Bb1 1.2 Bb1
1.2 Bb1

Lb1

M
3
= bs = B 2.25 bs
4
N

Bd6 = 0.856m

Pentru n = 1.2

L... := 1.2 0.9 m = 1.1 m

Adopt ca valori: Bd6 := 0.9 m

Ld6 := 1.1 m

I.Verificare SLD
kN
kN
Ppld6 := ml Bd6 N1 + qg9 N2 + c N3 = 461.331
Pplg9 = 556.643
2
2
m
m
6 ed6
Nfd6
kN Pefmax Ppl
Pefmaxd6 :=
1 +
= 470.374 2
Ld6
Bd6 Ld6

Pefmind6 :=
Hd6
Ld6

6 ed6
Nfd6
kN
1
= 59.399 2
Ld6
Bd6 Ld6

= f Pfmax , verificare

Pefmin Ppl 0

Hd6 := 0.3 Ld6 = 0.33 m

H1d6 := Hd6 = 0.165 m


2

l1d6 := 30cm

II.Verificarea terenului de fundare la starea limita de capacitate portanta


Nsd6 := 0.75 Nfd6 = 196.678 kN

Msd6 := 1.5 Mfd6 = 55.944 kN m

Pcr = mc B11g9 N + q Nq q + c Nc c
Bd6
Bd6
N = 6.3 Nq = 13.9
Nc = 24.8
d6 := 1 0.4
= 0.673
qd6 := 1 + 0.3
= 1.245
Ld6
Ld6
Bd6
cd6 := 1 + 0.3
= 1.245
Ld6
Pefmed. mc Pcr

kN
Pcrd6 := mc Bd6 N d6 + qd6 Nq qd6 + c Nc cd6 = 1185.707
2
m

Pefmedd6 :=

Nsd6
kN
= 198.665
2
Ld6 Bd6
m
kN

kN
mc Pcrg9 = 1185.707
2
2
m
m

Pefmedg9 = 198.665

Repartizarea momentului dat din excentricitate:


Mb = Nfd6 e1 e1 :=
Ks
Mbst = Mb
Ks + Kf
4 Kb
Ks =
hst

Bd6
2

bs
2

Mb = Mfb + Mbst

= 0.25 m

Mfb = Mb Mbst

K.s - rigiditatea la rotire a stalpului f(reazem)

Ks := 0.4

Eb := 240000

daN

Ib :=

40cm
( 40cm)
12

cm
2

Kb := 0.6 Eb Ib = 30720 kN m

If :=

Kf = Kp If

Ld6 Bd6
12

1 kN 0.825 kN 100000 kN 63000 kN


3
3
3
3
m
m
m
m
=
m

0.75

kN

m
4

213333.333 cm

1 kN 0.825 kN 100000 kN 63000 kN


3
3
3
3
m
m
m
m
1

kN
3

25900

kN
3

0.75

kN
3

kN
kN
kN
Ks1 := 100000
25900
= 74100
3
3
3
m
m
m

bs
kN
Kp :=
Ks1 = 32933.333
3
Bd6
m
4 Kb
Ks. :=
3.0 m

kN

= 0.067 m

= 400000

bs
Kp = Ks1 =
K
Bs6 s1
kN
1 0.75 .. 100000 63000
Ks1 =
100000
Ks1 =
3
1 0.825 .. 100000 Ks1
m

kN

cm

Kb = 0.6 Eb Ib

kN

Kf := Kp If = 2200.77 kN m

Ks.
Mbst := Mb
= 62.216 kN m
Ks. + Kf

Mb := Nfd6 e1 = 65.559 kN m

Kf
Mf := Mb
= 3.343 kN m
Kf + Ks.

You might also like