You are on page 1of 1

DESIGN OF RETAINING WALL

Wall Properties Wall thickness, mm Wall width, mm Concrete cover, mm Continuous Bar Vertical bar diam., mm Horizontal bar diam., mm Area provided by Vert. Bars, As Design of Reinforcement Ultimate Moment Compressive Strength Steel Yield Strength Effective Depth w rho reqd rho min rho max

= = =

250 mm 1000 mm 75 mm

= = =

10 mm 10 mm 261.79939 mm

@ @

300 mm spacing 300 mm spacing

= = = = = = = =

57.0382 kN-m 20.7 Mpa 275.8 Mpa 170 0.1135389 0.0085216 0.0009 0.0371501

o beta

= =

0.9 0.85

As As As

= = =

1448.7 153 6315.5

1448.7 1448.7 1448.7

As reqd As reqd Extra Bar Bar Diam As

= =

2 1448.6704 mm 2 1186.871 mm

= =

16 mm 1608.4954 mm Ok

Spacing =

2 125 mm

Vu Shear

217 kN

0.85

Shear Provided by concrete d

336.67191 mm