Conductance Analysis at Varying Temperatures

The document contains graphs and data tables relating to the conductivity of a mixture over time when heated to different temperatures (20C, 30C, and 40C). It includes linear regression equations that best fit the conductivity data at each temperature. It also contains an Arrhenius plot of ln(k1) versus 1/T that is used to determine the activation energy of the mixture.

Uploaded by

cutetamtam101
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views5 pages

Conductance Analysis at Varying Temperatures

The document contains graphs and data tables relating to the conductivity of a mixture over time when heated to different temperatures (20C, 30C, and 40C). It includes linear regression equations that best fit the conductivity data at each temperature. It also contains an Arrhenius plot of ln(k1) versus 1/T that is used to determine the activation energy of the mixture.

Uploaded by

cutetamtam101
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

40C

2.00E+01
1.80E+01
(1/Gt)/(1/G -1/Gt)

1.60E+01
1.40E+01
1.20E+01
1.00E+01

y = 0.006x + 0.9572
R = 0.9903

8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00
0

500

1000

1500

2000

2500

3000Time/s

Standard
Error
0.957152 0.113255
0.35892 0.004874

Coefficients
Intercept
X
Variable
1

5.00E+00

20C

4.50E+00

(1/G)/(1/G-1/G)

4.00E+00
3.50E+00
3.00E+00
y = 1.31E-03x + 8.40E-01
R = 9.59E-01

2.50E+00
2.00E+00
1.50E+00
1.00E+00
5.00E-01
0.00E+00
0

500

1000

1500
time/s

2000

2500

3000

Coefficients

Standard
Standard
Error
0.839741 0.05197
0.078692 0.002236

Intercept
X
Variable
1

1.20E+01

30C
(1/Gt)/(1/G -1/Gt)

1.00E+01
y = 0.0038x + 0.4943
R = 0.9841

8.00E+00
6.00E+00
4.00E+00
2.00E+00
0.00E+00

time/s
0

500

Coefficients
Intercept
X
Variable
1

1000

Standard
Error
0.494312 0.094153
0.22801 0.004015

1500

2000

2500

3000

2900

Conductance vs Time of mixture at


30C
2500
Conductance/S

2700

2300
2100
y = 2.47E+03x-1.44E-01
R = 9.72E-01

1900
1700
1500
1300
1100
0

2900
2700

10

20

30
Time/min

40

50

60

Conductance Vs Time of Mixture


at 20C

Conductance/S

2500
2300
2100
1900

y = 2.75E+03x-1.67E-01
R = 8.27E-01

1700
1500
1300
1100
0

10

20

Time/min
30

40

50

60

Conductance/S

Conductance/S vs Time of Mixture at


40C
2100
1900
1700

y = 2.66E-01x2 - 2.32E+01x + 1.74E+03


R = 9.24E-01

1500
1300
1100
0

10

20

30

40

50

60

Time/min

+
0
3.15E-03

3.20E-03

3.25E-03

3.30E-03

3.35E-03

3.40E-03

3.45E-03

-0.5

ln k1

-1
y = -6318.2x + 19.21
R = 0.6491

-1.5
-2
-2.5
-3

lnk1
-1.24
-2.63
-1.05

1/T K

temperature/C
3.19E-03
3.41E-03
3.30E-03

Coefficients
Intercept
X
Variable

Standard
Error
19.21 15.33433
-6318.18 4645.045