Professional Documents
Culture Documents
Prof. Dr. Ismail A. Abdallah
Prof. Dr. Ismail A. Abdallah
By:
Prof. Dr. Ismail A. Abdallah
Acceptance Limits
Not Exceeds 1.59 Mm
Remar ks
7.2 9.3.1.a 9.3.1.b
Individual IP not exceeds 25.4 mm Aggregate IP not exceeds 25.4mm in 30.48 cm weld length
Individual IP not exceeds 50.8 mm Aggregate IP not exceeds 76.2 mm in 30.48 cm weld length
9.3.2.a 9.3.2.b
Individual IF not exceeds 25.4 mm Incomplete Fusion Aggregate IF not exceeds 25.4mm in (IF) 30.48 cm weld length Cold Lap (CL) Individual CL not exceeds 50.8 mm Aggregate CL not exceeds 25.4mm in 30.48 cm weld length The density of the concave area shall not exceed the density of the adjacent of the base metal . And if the density is more the burn through acceptance limits should be applied. Individual BT not exceeds 6.35 mm Aggregate BT not exceeds 12.7 mm in 30.48 cm in weld length
9.3.4.a 9.3.4.b
9.3.5.a 9.3.5.b
9.3.6
Remar ks
9.3.8.a 9.3.8.b 9.3.8.c 9.3.8.d 9.3.8.e
Porosity (P)
9.3.9
Individual HB shall not exceeds 12.7 mm length. Aggregate HB shall not exceeds 50.8mm in 30.48 cm in weld length. Only star cracks and crater cracks are permitted with length shall not exceed 3.96 mm. Undercut length shall not exceed 50.8 mm in 30.48 cm weld length.
9.3.9.4
9.3.10
9.3.11