3.2.1 กฟน เชื่อมต่อ
3.2.1 กฟน เชื่อมต่อ
.!. 2551
% &'
(
1
.!.2551
1.
) !&(*
?
@
?".
%)
@
?-.*!1
@
?-./
@
?-./! @
?-.@
?-.-!
E @
-.*!1
#
,/
-./
)A
!
#
-.*!1
#
)A 1
/
!
-. * ! 1
#
,/-./
#
)A /
!
#
,-
+
,
-.* ! 1
1
/ #
# C9
1 -. - !
E
2
?-.-!
E@
?-.-!
@
?)-!*!@
?1)@
?1)@
? 1
,,#
!+@ (islanding)
?*#
@
(teleprotection)
?-.*!1
@
?)*0%)
1
+.
+
/
0
1
#
*#
+# -
++
-.*!1
$ #AA#! *
!1 $#
$.". 2550
)*0%)/
)
/
RTU)@
)*0%./
?#-+.
SCADA/EMS@
?#-+.
SCADA/DMS@
3
2. &+,-%*.
2.1 &+,-%*
*g
# 02%#9
!
,
!)*0%
, 6
!#9 + #-. /!
1#
1*K!#! #()*+%
#
9
2.1.1 $/!8 +/
-.#
$9
6
/
$*g
#*K!#! #
2.1.2 $/
$9
6
#1
)
!#9
/
,+ #-./!
#9
!)*0%
,
6
!#91)
2.1.3 $/ !
!
#
,
*+!8!4 $, *4#
2.1.4 $/)04 $/
1
+ #-./
#
* ./
02% 6
4 #1 -.
,
2.2
h#
9 /#-./! #
9
2.2.1 -.-!
E (Small Power Producer, SPP)
2.2.2 -.-!
E (Very Small Power Producer, VSPP)
2.2.3 -./
!
2.2.4 -.*!1
3. &0)012)
-./! 1, /
!)*0%
.*,
/
h#
9*g
4
+
+!8!o/
$!1 0
)A
)A / #
$!1 0 #9
*4# (
,
-*
%+
*g
# CJ-./! 1#*K!#! ,1
**g
) $
+ /I
!
J
+
+!8!o1,
*
,*
I $ *4#, #
,-./! 1#,*K!#!
4. -) 4 &
012) (5 &5
#02%*! 0 #
-./! 11 # #
1
/
, #
9
4.1 1
230/400 %
4.1.1 -./! #1
, 1 + + (1
#
1
!
10 !#%
4.1.2 -./! *! 0 #
1 #1
!
250 !#% 1
# 0 #,#
. $!1 0 !
250 !#% 1# 0
#,#
12 !% J9
*
4.2 1
12 !%
!
4 #% / 1
4.3 1
24 !%
!
8 #% / 1
4.4 *! 0 #
!
/
4.2 4.3 /#+ 69
115 !% + #9
9
!
180 #% / 1
#9
9*! 0 #
)A /1
#
1
1
$!1 0 +
J(J *4# (
5
/,+
/
+ 1
+ +
!
$!#,+
,
,+
*
,+.,*
+(
,+
*
,+.,*/
1
5.1.2 , .&
(voltage regulation) -./!
)A
!
1
/,#
/
.
02% 6
5.1.3 .%&5 -./!
)A
!
1
/ ,+#1/
!
85 !+#+ (
#,+#1 (short circuit interrupting capacity) )*0%#1,
1 ,+#1!
25 ,+#1+.+)1)
1
#9
9$*#
/!
*+
+#$#
8% (protection coordination) )*0%*#
5.1.4 D&D
2
,. -E)&) 1
-./! #9-.
1
!
1
4 /1
#1
230/400 %
5.2 -. / ! /
-
# 02% $! 1 0
! -. / ! 1
"Jp ,
-!J9
#9 1 ,+
) ,#
,+
#1 (
, C#C
/
), *K!#!
( 1 *g
*#*)
-./! 1#-!
6
6. &
.,-4*-
6.1 -./! 1*g
-.#-! !#9 #
+ (# #
,/
$#
C91
,/-! /
#9
91 +#*4 /
-./! + # !#9
#
,)*0%* //
/#
GH -!,*"
/*g
*
GH -!,*"
6.2 ,*# (instrument transformer) /# #
1
# # %
I
6.3 #
,)*0%*1 6
#
/
+!,
(+!,
1)CJ 1*
,*
#9
9
1*g
-.
6.4 -.1
!
/I # #
,)*0%* $
*sA /,1/
7. 1-.
-./! #
1
#p0
.*,
(+!,
2)
.*, ,
#9
J9
.#
, 1
-./+#AA ,
#9,*4 1
CJ
1
$!1 0 ,
*g
I
*
7.1
1+ (E
+(
#)*0%+!%#
/
0*$
*4#/
*K!#!
)#p
+!%#
91+ (
E
/
,
*
7.2 !"#$%&'()&!*++,-!./) 01223 /&.456478(1223 ! 0"79"/6 :+!*++/&. !1223 ;-!<7=.
>?%!*@:+A!.@:; 69 <!$& 115 8,7,=7(B C*(6&.4) ;<'6&AD7.1223 >?%'? connection diagram
@6 ;>?%()&:+!*++/&. !1223 ;-!<7=."DG;A++ WYE (grounded) KL <!:+!5DA++ !
7
7.6.3 0! )$/
)*0%#
-./!
!
1+,,
#
$#9,1 ,
8
+E1/
$!1 0
+ (
!
E
1
*
!
-./! 1
#-! /1 , + !J9
7.6.4 /
0)*0%1
*g
-./! $)04 $, + (/
) 1
/
-./! /
$
#
*)
-.
/! 0) 1
$
#
1*K!#!
# ) 1
, 6
h
#9
+ !J9
#)*0%-./!
8. ,-4*-&
-./! 11# ,!#9)*0%*#
#
9
8.1 456/&M#6+!8 !C*(6&.(8@(:S.!?"70B>?%'?' (!] ;>?% !1223 ;-!<7=.0&'!:+ ( '>?%L <;@M;K8%.
A;+ 1
8.2 456/&M#6+!8 !C*(6&.(8@(:S.!?"70B M<6"<' *K':+ !D3&.:;!*++1223 /&.(;"&. /^S;&05):+
!5DA++ !"#$%&'()&!*++,-!./) 01223 ( 'K8%.A;+ 2
8.3 ,@0>:%=1D !1223 ;-!<7=.C*'? automatic reclosing >?%!*++K 0K).A7*!*++K 0D3&;
& _ @:. ;:S;456/ &M#6+ !8 !C*(6&.A;)M C=) K=8(#B(:@(&;&:(,;':(8/&.(;C*(6 &.D7@ !
C) 012&&)&;>?% automatic reclosing /&. !1223 ;-!<7=.C*>L . ; !1223 ;-!<7=.
C*1')!:+48@#&+-= '"K?0< 0()&&ND!OB/&.456/&M#6+!8 ! ";$%&.C ! reclosing ;?S
8.4 "'$%&"8@ islanding :+!*++456/&M#6+!8 ! <!$&!*++1223 /&. !1223 ;-!<7=.+ .K)=; 456
/&M#6+!8 !C*(6&.'?!*++D3&.:;>?%K ' !P(!=CC:+A7*D7@=.C! interconnection circuit
breaker \ 0M; 0.1 =8; >?
9
9. ,,4J
456/&M#6+!8 !C*(6&.&&A++!*++-=+-N' !C) 012C !"@8;"-!$%&.L ";8@1223 /; ;:+
!*++,-!./) 01223 O CN@"#$%&'()& @:.;?S
9.1
power factor
9.1.1 -./! ,)#,#
$/+#
6
#,#
+.+), +)
4 *!
+.+)
117.6
70.4
23.6
11.8
410
237
4 h)h!
+)
106.4
63.6
21.8
10.9
371
214
10
+.+)
123.0
72.5
24
12.0
416
240
+)
96.0
57.3
21.6
10.8
362
209
4 *!
+.+)
118.0
71.0
23.6
11.8
410
237
4 h)h!
+)
113.0
67.0
21.8
10.9
371
214
+.+)
123.0
72.5
24
12.0
416
240
+)
113.0
67.0
21.6
10.8
362
209
4) -.*!1
+
+! 8!o / -. ) power factor
CJ1
*g
,0
* $ ),#p )04 $
/
9.2
!"##$
GH -!,*"
1*g
-.) (
/./
+ #-.-!
E1
*K!#!
GH -!,*"
9.3
&'(!)
-.1)
/+ ,#
$1)!
1 # !8
*!
/
702%,#
$#
*48)!1,)+
(PRC-PQG-02/1998) (+!,
3) *#*)
702%,#
$z# J9
/ /-##/ h# +)
* #9
91*K!#! #9
,
/
1+
)04 $
(+!,
4)
9.4
+,)-
-.1)
/+ ,+,,#
: %
!1)!
1 #
!8 *!
/
702%: %
!#
*48)!1,)+
(PRC-PQG-01/1998) (+!,
5) *#*)
702%: %
!z# J9
/
/-##/ h# +)
* #9
91*K!#! #9
,
/
1+)04 $
(+!,
4)
12
9.5
/0"##$
12&3415
630"##$
-./! !
%% 1,*#
1
,+ +.
1)
!
0.5 ,+$!#!
%%
9.6 2-28&(!) 9:'"##$
$/+ (1+,)#)04 $
*+!8!4 $ -.
*4
*
911# ,!#9#)04 $
(power quality meter) )0+#!*g
*
(+!,
6) 0 ,
1)-.
- -.
!
#-!#
!
1 #%
-
-.
!
!!
%%,
#-!#
!
250
!#%
10. ,
10.1
14
10.3
69
=() 115 -66 2,
10.3.1 # 0 1)#C9
#
*
- active power (#%) 3 Phase
- reactive power ( %) 3 Phase
- voltage (!% ) 3 Phase
- ampere (,,*%) 3 Phase
- power factor (pf)
- frequency (:!C%)
10.3.2 +(
)*0%#1 , protection relay *
- information messages 1 protection relay
overcurrent, earth fault *g
- status )*0%#1 (circuit breaker , isolated switch)
- status ground disconnecting switch
- status protection relay (on/off)
- status circuit breaker
- status disconnecting switch
- main protection tripping alarm
- control )*0% )*0% interconnection circuit breaker
-
I
1 *g
//
)
15
10.4
12
=() 24 -66 2,
10.4.1 # 0 1)#C9
#
*
- active power (#%) 3 phase
- reactive power (#%) 3 phase
- line to line voltage (!% ) 3
- ampere (,,*%) 3 Phase
- power factor (pf)
- frequency (:!C%)
10.4.2 +(
)*0%#1 , protection relay *
- status )*0%#1 (circuit breaker , isolated switch)
- status ground disconnecting switch
- status protection relay
-
I
1 *g
//
)
10.5
34)B=?-3)34)5@!24)
/F50,
"##$ D
)
4 0
+# )+ # */+# circuit breaker , protection relay 1 *g
,
I
. 1 *g
/
)
,+- . ".
% )
,+- $! % ".
%
)
#9
!/,+. ,*g
"1 $!%".
%
)
16
10.6
-G134)5
)*0%)
(Remote Terminal Unit) +. ##-+.
SCADA/EMS ".
%)
real-time
update .
!
2 !
+ #. status ,
!
10 !
+ #
. #)*0%)
(Remote Terminal Unit) + (!##-+
.
SCADA/EMS #-+.
SCADA/DMS
protocol DNP 3 subset level 2 (serial communication) $ certificate .
#9+ (,+
$!%".
%)
, #+.
*g
*#
#! #9
9 ##-+.
SCADA/EMS
#-+.
SCADA/DMS
1-
MEA Network
1)
,!8
#9
/ *g
*
#++
10.7
VT, CT Transducer
-.-!
E ,-.-!
,
/ VT. , CT. +(
+
-.-!
E !
// VT. , CT. +(
$#)
VT. , CT. 6
-!$
!
".
%1)
(0.5%) /+ # Protection + #. 10.3.2 , 10.4.2 ,
6
-!$
!
".
%1)+ (0.3%) /+ #
metering + #. 10.3.1 , 10.4.1
10.8
5
BR)D9,
-.-!
E ,-.-!
,
1.,/)*0%)
(Remote Terminal Unit) $/
,-.-!
E
1.,/)*0%# (Remote Control Switch : RCS) $/
)*0%# !# ,
# ,
#1
#+ ,1
1
11.1.2
11.1.3
1
+
$$!1 0 E
#0 !1
, ! (.) -./! *g
-.#-!/
,
*/
/ (# .
11.2
#)04 $
(power quality meter) -./!
11.2.2
11.2.3
19
%).
1
K
,-4*
)*0%
*g
* 6
! #
9
#
)*0%
TOU Meter
Instrument Transformer
Circuit Breaker
6
!
ANSI C12.16 , ANSI C12.20
or
IEC 61036 , IEC 60687
IEC 60044-1 , IEC 60044-21
or
ANSI C57.13
IEC 60056
or
ANSI C37.11
or
NEMA SG4
Protection Relay
IEC
-.-!/
supplier list
#
9
ABB,Areva,GE,Merlin Gerin(group Schneider) ,Reyrolle,
Schweitzer(Sel),Siemens , SEG
Disconnecting Switch
IEC 60129
or
ANSI C37.30 , ANSI C37.32 , ANSI C37.34
IEEE C37.41 , ANSI C37.42
or
NEMA SG2
IEC
Internal Arc test IEC 602271-200
20
)*0%
6 !
IEC
21
%).
2
1-.
22
1547
23
24
Device no.
25
Function
Synchronizing check
Trips
-
59/27
52A(or 52B)
50/51, 50N/51N
59N
67/67N OR 32
52B, 52T
52B, 52T
52A(or 52B)
68
81
OR Reverse Power
Voltage relay Block Closing Circuit While De-energize
Under and Over Frequency
52B
Note
For 52B
For 52B
Remark
25
Device no.
25
59/27
50/51, 50N/51N
59N
67/67N OR 32
68
81
Function
Synchronizing check
Over and Under Voltage relay
Phase and Ground Overcurrent
Zero Sequence Overvoltage
Directional Overcurrent and Ground Overcurrent
OR Reverse Power
Voltage relay Block Closing Circuit While De-energize
Under and Over Frequency
Trips
-
52A(or 52B)
52B, 52T
52B, 52T
52A(or 52B)
-
52B
Note
For 52B
For 52B
Remark
26
Device no.
25
50/51
50N/51N
59/27
59N
63
68
81U/81O
87T
MCB
27XM
Function
Synchronizing check
27
Trips
-
Note
52B, 52T
52B, 52T
52B
52B
52B, 52T
For 52B
52B
52B, 52T
For 52B
Device no.
25
50/51
50N/51N
59/27
59N
63
68
81U/81O
87T
MCB
27XM
Function
Trips
-
Note
52B, 52T
52B, 52T
52B
52B
52B, 52T
For 52B
52B
52B, 52T
Synchronizing check
For 52B
<' 0"<(N !(8@(:S. Lightning Arrester (LA) M;!O?>?%'? !"#$%&'()&:+ !1223 ;-!<7=. @6=0!*++Underground
28
Device no.
21
25
50/51
50N/51N
59/27
59N
63
68
81U/81O
87T
MCB
27XM
Function
Trips
52-1,52-2
-
Note
52B, 52T
52B, 52T
52B
52B
52B, 52T
For 52B
Distance relay
Synchronizing check
For 52B
52B
52B, 52T
<' 0"<(N !(8@(:S. Lightning Arrester (LA) M;!O?>?%'? !"#$%&'()&:+ !1223 ;-!<7=. @6=0!*++Underground
29
Device no.
21B
25-1
25-2
25
50/51
50BF
59/27
59N
63
68
81U/81O
87B
87L
87K
MCB
27XM
Function
Backup Distance relay
Synchronizing check
Synchronizing check
Synchronizing check
Trips
52-1, 52-2
-
52B, 52T
52B
52B
52B, 52T
Note
For 52-1
For 52-2
For 52B
-
52B
For 52B
52B
52B, 52T
<' 0"<(N !(8@(:S. Lightning Arrester (LA) M;!O?>?%'? !"#$%&'()&:+ !1223 ;-!<7=. @6=0!*++Underground
30
Device no.
21B
25-1
25
50/51
50BF
59/27
59N
63
68
81U/81O
87B
87L
87K
MCB
27XM
Function
Backup Distance relay
Synchronizing check
Synchronizing check
Trips
52-1
-
52B, 52T
52B
For 52-1
For 52B
-
52B
52B
52B, 52T
For 52B
Note
52B
52B, 52T
<' 0"<(N !(8@(:S. Lightning Arrester (LA) M;!O?>?%'? !"#$%&'()&:+ !1223 ;-!<7=. @6=0!*++Underground
31
Device no.
21B
25-1
25-2
25
50/51
50BF
59/27
59N
63
68
81U/81O
87B
87L
87K
MCB
27XM
Function
Backup Distance relay
Synchronizing check
Synchronizing check
Synchronizing check
Trips
52-1, 52-2
-
52B, 52T
52B
For 52-1
For 52-2
For 52B
-
52B
52B
52B, 52T
For 52B
52B
52B, 52T
Note
32
%).
3
M46*.&
&
-J(N,)5.,%
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
%).
4
&O
.
2
5%,4J
1.
1 1#,+: %
!,,#
$1)-./
+#AA $*!
-
)04 $
/
+
1.1
1!#91#)04 $
*g
1 +#* %
,!#91#z
* 1 +#* %4 #
1# -!
-./+#AA
/
+4 /
1!CJ+ 4
54
%).
5
M46*P *
)
&
-J(N,)5.,%
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
%).
6
,4%&)&,4J
Power Quality Meter Requirement
1. Power quality meter shall measure and record the 3 phase true RMS electrical value in 2 categories
which are Profile Recording and Event Recording.
2. Profile recording is the continuous recording of average, minimum and maximum RMS value over 10
minutes period including Voltage, Ampere, Real Power, Reactive Power, Apparent Power, Power
Factor, Harmonics (Voltage, Current and Power up to 50th), Voltage Unbalance (Unbalance Factor,
Positive Sequence Voltage, Negative Sequence Voltage and Zero Sequence Voltage) and Flicker
(Short Term Flicker Index, Pst, and Long Term Flicker Index, Plt). Note except Plt which calculate
over 2 hours period.
3. Event recording is the condition trigged recording of a voltage and current waveform of an abnormal
event including Voltage Sag (Dip), Voltage Swell and Short Interruption with the minimum sampling
resolution of 128 samples per cycle and allow user to adjust the trigger condition.
4. Power quality meter shall comply with international standard IEC 61000-4-30 (power quality
measurement method) class A performance, IEC 61000-4-7 (harmonics) and IEC 61000-4-15
(flicker).
5. The internal memory of power quality meter shall be enough to store all measurement data at least 7
days without data loss.
6. Power quality meter shall have an internal battery backup for ride through capability at least 1 hour in
case of power supply failure and shall have an automatic restart function in case of back up battery
deplete.
77
%).
7
,-4*,
(Remote Terminal
Unit) (2&&-%1
!1
*,
)*0%)
(Remote Terminal Unit) -.1#-+.#
#-+.
SCADA/EMS (0 69 115 !%) ,#-+.#
#-+.
SCADA/DMS (0 12 24 !%) ".
%
)
1
Input Output Point *g
*
1.2 K
%% 1
)*0%)
(Remote Terminal Unit) -.1#-+.#
#-+.
SCADA/EMS #-+.
SCADA/DMS ".
%)
* DNP 3.0 Subset Level 2 (Serial Communication)
Device Profile and Implementation Table */
/
-+.
SCADA/EMS
78
1.3
Status Input
1 /
#
J.) 0%!/
#p0 #
) 0% (Sequence of Event) ) I 1 !!!
!/1,*g
2 ,
(1) Single Contact, Two-State Status + #+.
! Alarm
(2) Double Contact + #+.+(
C%!%+!%
1.3.3
Control Output + #+#)*/+# Interconnection Circuit Breaker
11# , Select-Check-Before-Operate (SCBO)
1.4
.5
,-4*, (Remote Terminal Unit)
-./! 1# ,!#9,1
! AC , DC + #1
/
)*0%//
#-+.#-
SCADA/EMS -
SCADA/DMS
1
2 , *g
1.5
-&-,
0-. *#*)
*
,*.*, 1
79
80
%).
8
( %% (communication channel)
4012) 2
69 115 )*
-./! /
69 115 !% 1 ++
(communication channel) + (!#
3
,
++ -
+ /,
,+ $)*0%++
!)++
! base radio
"#$%+ 1 -./! (
TOT, True -./!
)
1.
&+,-%* %%
1.1 $)*0%)
(Remote Terminal Unit) -./! ##+.
SCADA/EMS (Supervisory Control and Data Acquisition / Energy
Management System) ".
%)
1.2 $)*0%*#
(protection relay)
1.3 $#)04 $
(power quality meter) -./!
1.4 $1+)04 $
(PQMS)
1.5 $/ !++ -./! #".
%)
-
!) ,"#$%
2.
%%
81
82
2.3 "#$%+ !#9-./! 1
1 $ ! ".
%)
, -./!
3.
&0)
3.1 -./! 1#-! /1 /
*#*)++
, /1 /
/
!
1# ,!#9 communication channel
2.1 #9
3.2
1
!
,1 /1 1! 2.1.1 1,1/ 4 #-.
/!
+. ,
+(
!#9/#
,
3.3 #-!, )#p )*0%++
1
+!9
+) MEA End Point CJ!#94 /
+(
-./! (
communication system diagram)
3.4 -./! 1# !)++
! base radio
, /+ (/
!#
3.4.1 -./! *g
-.1# )*0%!) trunked radio 2.2
3.4.2 -./! *g
-.
!
#
1$!1 0 E
#0 !1
, ! (.)
3.4.3
#
)A
-./! *g
-.#-!/
,
*/
/ (# .
3.4.4
*g
-.
!
*,/
)*0%!) trunked
radio //
#
3.5 -./! 1# "#$%+ 1 -./! (
TOT, True -./!
)
3.6 -./! 1#
,++#
30 ,,*% 1
2 1
$)*0%+
$1 /#)*0%++ !#9#94 /
+(
!#9-./!
83
3.7
+
+!8!o1
)A #/ ++
( * K -./! ! *4#++
$ #AA#! *4#$!%
3.8
+
+!8!o1*#*)++
1 *g
!1J9
,1/-./!
/
#
4.
(/
15 ( ,
z
#9+!9
24,000.00 *,
#
1 4 /
30
#
!
-.$#
.
,1
!# @+
#
)A !1 h$ !1 +
#
0 !1
, !@
$
!
#/
)A //!)
#9 1
,
/
/ (!), ,% .
/
-.
!
#9
9# ,
/
/ ( 1
*
,*
+
#
.
5. 5
,-4*(22
%% &
0
% 2.
.% ,-4*%% 5
1 -
&
5 (2
)
modem 56k
)
card
AC surge protector
)
)
)
cabling ,)*0%* I
)
)
OFC 24 cores
+
85
86
%).
9
( %% (communication channel)
4012) 2
12 24 )*
-./! /
12 24 !% 1 ++
(communication channel) + (!#
3
,
++ -
+ /,
,+ $)*0%++
!)++
! base radio
"#$%+ 1 -./! (
TOT, True -./!
)
1.
&+,-%* %%
1.1 $)*0%)
(Remote Terminal Unit) -./! ##+.
SCADA/DMS (Supervisory Control and Data Acquisition / Distribution
Management System) ".
%)
1.2 $#)04 $
(power quality meter) -./!
1.3 $1+)04 $
(PQMS)
1.4 $/ !++ -./! #".
%)
-
!) ,"#$%
2.
%%
2.1 ++ -
+ /,
,+ $)*0%++ , +(
!#9
*)*0%#
9
2.1.1 + /,
,+
! ADSS SM
24 cores 1
2 +
$
)*0% fiber optic termination * #9+,
87
2.1.2
+(
!#9-./!
)*0% industrial Ethernet switch 1
1 ) + (#/
+.*,+#AA 0
I. data channel
II. voice channel
cabling ,)*0%*
I
&0)
3.1. -./! 1#-! /1 /
*#*)++
, /1 /
/
!
1# ,!#9 communication channel
2.1 #9
3.2.
1
!
,1 /1 1! 2.1.1 1,1/ 4 #-.
/!
+. ,
+(
!#9/#
,
3.3. #-!, )#p )*0%++
1
+!9
+) MEA End Point CJ!#94 /
+(
-./! (
communication system diagram)
3.4. -./! 1# !)++
! base radio
, /+ (/
!#
3.4.1 -./! *g
-.1# )*0%!) trunked radio 2.2
3.4.2 -./! *g
-.
!
#
1$!1 0 E
#0 !1
, ! (.)
88
3.4.3
3.4.4
#
)A
-./! *g
-.#-!/
,
*/
/ (# .
*g
-.
!
*,/
)*0%!) trunked
radio //
#
3.5. -./! 1# "#$%+ 1 -./! (
TOT, True -./!
)
3.6. -./! 1#1)
,++#
20 ,,*%
1
2 1 $)*0%+
$1 /#)*0%++ !#9#9
4 /
+(
!#9-./!
3.7.
+
+!8!o1
)A #/ ++
4.3.2
4.3.3
4.3.4
4.3.5
- 4
5 (2
)
cabling ,)*0%* I
)
)
OFC 24 cores
+
90