Professional Documents
Culture Documents
A B C D
A B C D
Stock product
The following sizes are kept in stock for quick delivery. Satin anodised and RAL9010 available. 1502, 2002, 2502, 3002, 3502, 4002, 4502, 5002 200 x 150, 300 x 150, 300 x 200, 400 x 200
A B C D
A B C D
www.airtherm.co.uk
Stock product
The following sizes are kept in stock for quick delivery. RAL9010 finish, with and without opposed blade dampers. 1502, 2002, 2502, 3002, 3502, 4002, 4502, 5002, 5952 Overall face
A B C D
A B C D
NV1
NV2 Door
NV3 Darkrooms
www.airtherm.co.uk
A B C D
A B C D
A B C D
A B C D
www.airtherm.co.uk
A B C D E
31mm flat flange (Opt) Nominal + 30mm 33mm 76mm 31mm Actual neck + 15mm
A B C D E
36mm bevelled (Std) Nominal + 45mm 33mm 76mm 36mm Actual neck + 9mm
Stock product
600mm2 units are kept in stock for quick delivery.
www.airtherm.co.uk
Stock product
The following sizes are kept in stock for quick delivery, RAL9010 finish. 254mm, 356mm, 457mm, 533mm (Core sizes)
SWF 1 2 3 4
D (mm) 40 40 40 40
Stock product
Adjustable blade swirl diffusers are kept in stock for quick delivery, RAL9010 finish.
SWA 1
A (mm) 595
B (mm) 537
C (mm) 240
Dimensions explained on fixed swirl diagram. Dimension B describes diameter between outermost points of deflector blades. Not a small spigot as with fixed swirls.
www.airtherm.co.uk
Stock product
The following sizes of four way blow ceiling diffuser are kept in stock for quick delivery. RAL9010 finish, with and without opposed blade dampers. 1502, 2002, 2252, 3002, 3752, 5952 Overall face
Stock product
All sizes shown in the table are kept in stock for quick delivery, in both RAL9010 and satin anodised finish.
Size A B C D E F G H
Nominal (mm) W H 244 321 164 473 625 524 651 259 778 905
Overall (mm) W H 297 373 208 525 678 576 703 303 830 957
Depth
62
106
194
100
144
232
www.airtherm.co.uk
Slot number 1 2 3 4 5 6 7 8
Overall face (mm) 76 115 154 193 232 271 310 349
A B C D
A B C D
www.airtherm.co.uk
DIMENSIONS (mm) A B C 257 149 225 307 199 275 357 249 325 407 299 375 457 349 425
www.airtherm.co.uk
Pressed steel ceiling diffuser No.28 Type B Incorporates a cord operated damper
10
www.airtherm.co.uk
Stock product
The following sizes are kept in stock for quick delivery. Size 180mm x 80mnm 250mm x 150mm 250mm x 150mm 250mm x 150mm 250mm x 150mm 250mm x 150mm 250mm x 150mm 400mm x 300mm 400mm x 300mm 400mm x 300mm 400mm x 300mm 400mm x 300mm 400mm x 300mm To suit duct diameter 100mm / 125mm 150mm / 160mm 180mm / 200mm 250mm 300mm / 315mm 350mm / 355mm 400mm / 500mm 400mm 450mm 500mm 560mm 630mm 710mm
Stock product
The following sizes are kept in stock for quick delivery. 100mm, 125mm, 150mm, 200mm, 250mm, 300mm, 315mm.
www.airtherm.co.uk
11
Nylon coating
A specialist finish, nylon coating is used in favour of polyester coating where extreme durability or resistance to static electricity build up is needed. These qualities mean computer room floor grilles are often nylon coated, as static electricity build-ups in data centres can be disasterous.
x x
x x x
Drum jet Linear slot Linear ceiling Circular diffuser Fixed swirl Adjustable swirl
x x x
RAL9010 only
12
www.airtherm.co.uk
Aluminium dampers
Volume control damper Series VCD
A large format, all aluminium damper, HVC VCDs can be made in larger sizes than their steel counterparts. Using a protected push rod linkage means these dampers require minimal torque to operate, even at large sizes.
www.airtherm.co.uk
13
Stock product
WL100
The following sizes of 38mm pitch standard louvre are kept in stock for quick delivery. Mill finish, powder coating to RAL/BS colour optional. 1502, 2002, 2502, 3002, 3502, 4002, 4502, 5002, 5502, 6002, 7002, 8002, 9002, 10002
WL75
WL50 WL38
14
www.airtherm.co.uk
www.airtherm.co.uk
15
Options include: Doors. Internal dividers (insulated or un-insulated). Flat, single slant, double slant and HIP roofs.
16
www.airtherm.co.uk
Bird mesh
Screwed to the back of louvre blades, bird mesh prevents large objects like leaves, rubbish and birds being able to penetrate the louvre. Bird mesh has no real effect on airflow.
Nylon coating
A specialist finish, nylon coating is used in favour of polyester coating where extreme durability or resistance to static electricity build up is needed.
Insect mesh
With much smaller gaps than bird mesh, insect mesh prevents all but the smallest objects penetrating the louvre. The vast majority of insects and debris are caught.
Fixing methods
Although normally drilled on site, louvres can be supplied with face fixing holes in the flange, or rear mounted fixing lugs.
www.airtherm.co.uk
17
Steel dampers
S100 Fire Dampers
S100 Fire Dampers are standard fusible link operated curtain type fire dampers. Spring driven to enable installation in vertical or horizontal alignments, S100 dampers are available with HEVAC, plasterboard or curtain frames and can be fitted with fixing lugs to suit drop rod installa
Certification
S100 Fire Dampers have been tested to and passed: BS1366-2 (ISO10294-1): 4 Hour fire test at 300 Pa. Test conducted by Building Research Establishment. BS476-20: 6 Hour fire test. Test conducted by Warrington FRC. Fire damper cases are manufactured in accordance with DW144.
Options
Installation frames: HEVAC Plasterboard Curtain Fixing lugs Fully galvanised Stainless blade pack & galvanised case Fully stainless Stainless available in 430, 316 and 304 grades. Square spigotted Circular spigotted Flat oval spigotted
Material:
Connection types:
Certification: S200
S200 Fire Dampers have been tested to and passed: BS1366-2 (ISO10294-1): 4 Hour fire test at 300 Pa. Test conducted by Building Research Establishment. BS476-20: 6 Hour fire test. Test conducted by Warrington FRC.
Certification: S300
S300 Fire Dampers have been tested to and passed: BS476-20: 6 Hour fire test. Test conducted by Warrington FRC.
Options
Material: Fully galvanised Stainless blade pack & galvanised case Fully stainless Stainless available in 430, 316 and 304 grades. Square flanged
Connection types:
18
www.airtherm.co.uk
Certification
S600 Fire Smoke Dampers have been tested to and passed: BS476-20: 6 Hour fire test. Test conducted by Warrington FRC. Fire damper cases are manufactured in accordance with DW142.
Options
Installation frames: HEVAC Plasterboard Curtain Fixing lugs Fully galvanised Stainless blade pack & galvanised case Fully stainless Stainless available in 430, 316 and 304 grades. Square spigotted Circular spigotted Flat oval spigotted
Material:
Connection types:
Options
Material: Fully galvanised Stainless blades & galvanised case Aluminium blades and galvanised case Fully stainless Stainless available in 430, 316 and 304 grades. Square flanged Square spigotted Circular spigotted Flat oval spigotted
Connection types:
www.airtherm.co.uk
19
Specifications:
Materials: Extruded uPVC frame and blades. Integrated flexible plastic blade nose seals. Brush side seals. Rolled steel section inside each blade for reinforcement (not exposed to airstream). Stainless steel screws to join frame (not exposed to airstream). Finish: Sizes: White. Minimum size 300mm x 300mm / 300mm . Maximum size 1000mm x 1000mm / 1000mm . Above these sizes units would be made in sections.
Corrosion resistance In coastal or swimming pool applications, traditional steel dampers will corrode very quickly. uPVC on the other hand has excellent resistance to salt and chlorine, and cannot rust.
Precision linkage Manufactured from highly corrosion resistant materials, the custom designed gearset is so precise it can drive up to 10 blades and cogs with very limited play, for maximum performance even at large sizes.
20
www.airtherm.co.uk
Model B - Square, spigotted. Model C - Circular, spigotted. Model D - Flat oval, spigotted.
No cold bridge
Close a steel or aluminium volume control damper, and you will go on losing heat, not through airflow but conduction of heat from one side to the other. HVC large format uPVC volume control dampers have a theoretical U value of 0.973W/m2K when closed, atleast 40 times better than a steel damper and 250 times better than an aluminium unit. Of course this can help to cut heating bills, and reduces the carbon footprint of any building using them. *Figures sourced from www.engineeringtoolbox.com Thermal conductivity of steel and aluminium* Steel W/mK Btu 40 23.12 Aluminium 250 144.46
www.airtherm.co.uk
21
Flues & chimneys Natural ventilation & lighting Kitchen ventilation Air Conditioning Heat pumps & renewables Solar photovoltaic
Unit 8a Gainsborough Trading Estate Rufford Road Stourbridge West Midlands DY9 7ND