You are on page 1of 1

Roberge & Co (Thailand) Co.,Ltd.

SSP Tower3, 14 Fl. Unit A3, 88 Silom Rd., Suriyawong Bangrak Bangkok 10500
Tel: (66)2-634-4005 Fax: (66)2-634-4199 Email: sale@robergeandco.co.th www.robergeandco.co.th

Wood Seal - B™- Fire Retardant Penetrant


(Water Based - Non Toxic )
Flame Spread=35, Smoke Developed = 95

RECOMMENDED USE: INTERIOR - Wood Seal™ Fire Total Solids: 25 % - 28 %


Retardant - Class "B" penetrant can be used on any type of
Weight per Gallon: 9.2 lbs - 9.5 lbs
unpainted wood and many other cellulose materials. Paint or stain
can be applied over the treated material.* Application may be Specific Gravity: 1.11 - 1.15
accomplished by either brush, roller or spray methods. The
pH: 2.0 - 3.0
coverage rate should be 150-350 square feet per gallon, depending
upon the results desired. This product may be used on materials Flash Point: None
such as: Fir, Cedar, Redwood. Pine, Straw, Paper/Cardboard, Wall
Coverings, etc. Wood Seal™application is acceptable for use Color: Water Clear
Outdoors when the product is protected from rain and moisture. Coverage: 150-350 Square Feet - Gallon

EXTERIOR - If the wood surface will be exposed to water - a non- Volatility: Non-Volatile (Contains no VOC's)
flammable paint or coating* should be applied as a top coat after Water (Contains no petroleum
Wood Seal™ has dried. Solvents:
derivatives)

ENVIRONMENTAL REGULATIONS: This product complies with Toxicity: Non-toxic


U.S. Federal Regulations concerning the use of lead in paint AND Fungus
hydrocarbon emissions. Excellent
Resistance:

Mold Resistance: Excellent

Bacteria
* Make sure that a paint or coating is not flammable, and does Mildly resistant
Resistance:
not negatively effect the fire resistant properties of the Flame
Seal product. Linear Shrinkage: None

Moisture
None
Absorption:
SPOT TEST SECTION: Corrosive: Mildly, none when dry
1. WOOD TO BE TESTED MUST BE UNTREATED, UNPAINTED, CLEAN AND DRY.
2. BRUSH, ROLL, OR SPRAY BOTH SIDES OF WOOD SAMPLE IF POSSIBLE. APPLY AMPLE WOOD SEAL TO SATURATE THE WOOD.
3. USE PRODUCT IN AREA WITH ADEQUATE VENTILATION.
4. ALLOW TIME TO DRY.
5. TEST BURN WITH A FLAME OR TORCH TO CHECK THAT THE WOOD DOES NOT CONTINUE TO BURN WHEN THE FLAME IS
REMOVED.
*** ( NOTE: THE CHEMICAL MUST BE USED IN ITS " UNDILUTED" STATE. ) ***

WOOD TREATMENT:

APPLY WOOD SEAL FLAME RETARDANT TO THE WOOD BY SAME METHOD AS THE SUCCESSFULLY TESTED SAMPLE.
COVERAGE RATE SHOULD BE 150 - 350 SQUARE FEET PER GALLON.
ALLOW WOOD SEAL TO DRY.
EXTERIOR - IF THE WOOD SURFACE WILL BE EXPOSED TO WATER - A NON-FLAMMABLE PAINT OR COATING SHOULD BE
APPLIED AS A TOP COAT AFTER Wood Seal™ HAS DRIED.

Non Toxic, Non Hazardous


Not Harmful to Plants or Animals, (No PBDEs - Polybrominated diphenyl ethers)

“The Best Essential Solution” Asia Regional Authorized Distributor