5 comments

PeeyushUnfollow Follow Peeyush Peeyush Karambelkar 1. Air might be entering from flanges. 2. Condenser level of after condensers or inter condensers might not be adequate. 3. Nozzle choking. 4. Last stage ejector condenser(After condenser) pressure should be slightly positive other 21 days ago Unlike Like

Reply privately Flag as inappropriate Flag as promotion

AlanUnfollow Follow Alan

Alan Manza 1. Lower motive steam pressure supply going to the main ejector system 2. Air intrusions in the system 3. Condenser high level 4. Vacuum breaker leakage 5. Abnormality on the gland condenser fan 6. Rupture disc or relief valve problems 7. etc. 21 days ago Unlike Like

Reply privately Flag as inappropriate Flag as promotion

TomUnfollow Follow Tom Tom McCandless I like all of Alan Manza details but would add one more thing that happed in my facility. Some times if the water chemistry is off, the air ejector nozzle within the jet pump will scale up which diminishes the efficiency of the ejector package. Cleaning or replacement may be necessary to get the proper performance back. 19 days ago Unlike Like

Reply privately Flag as inappropriate Flag as promotion

ChrisUnfollow Follow Chris Chris Comi A recent failure I'm aware of involved freezing... 13 days ago Unlike Like

Reply privately

Flag as inappropriate Flag as promotion

AlanUnfollow Follow Alan Alan Manza You are definitely correct Tom. Servicing of air ejector nozzles is necessary during every PMS to maintain its effectiveness and efficiency. Thank you. 4 days ago Unlike Like