Numerical Voltage & Frequency Protection Relay

ARGUS 8

Description
The Argus 8 range of numerical voltage and frequency relays have the power and flexibility of microprocessor technology, giving a wide range of settings which are supplemented by advanced features such as metering, data storage and Fibre-Optic communications. Supervisory and self-monitoring features give added confidence to the user as well as reduced maintenance and down time. A menu-based interface gives userfriendly access to relay settings, meters and operational data.

Control
The basic 2 pole Argus 8 relay contains 7 programmable output relays, 1 of which have 1 CO contact, 1 NC contact and 5 have 1 NO contact The basic 3 pole Argus 8 relay contains 7 programmable output relays, 3 of which have 1 CO contact and 4 have 1 NO contact. Expanded variants provides 4 extra output relays, each having 1 NO contact The basic 2 pole Argus 8 relay contains 4 programmable digital (status) input The basic 3 pole Argus 8 relay contains 1 programmable digital (status) input, with an additional 4 or 8, provided in expanded variants

Applications
Capacitor Bank Ungrounded/High impedance earthed system AC Generators Transmission Lines Distribution Feeders

Features
Protection
Over voltage (59) Under voltage (27) Neutral voltage displacement Negative sequence overvoltage (47) Over Frequency (810) Under Frequency (81U)

Numerical Voltage & Frequency Protection Relay -Argus 8

Monitoring Trip circuit supervision (95) Storage of 500 time-tagged event records Storage of 5 multiple waveforms and status records Records upto 10 faults

Wiring Diagram

Metering
Primary RMS voltages Secondary RMS voltages Secondary RMS sequence voltages System frequency

User Interface User-friendly settings and indications Backlit liquid crystal alpha-numeric display with16-characters, 2 lines LEDs for protection healthy, trip and starting Push buttons for programming and resetting Communication Fibre-Optic or RS485 communication port at rear Data communication using IEC 60870-5-103 or MODBUS RTU protocol

Notes
1) Diagram shows 2ph-ph connections. See below for alternative connection. 2) Diagram shows ph-E+ 3Vo connections. 3) Diagram shows ph-ph+3Vo connection. 4) For the Phase-Phase of Phase-Earth connections, any phasing may be used.

Technical Information
Input Rating AC Voltage Settings Voltage 1,2,3,4 Definite time delay 63.5 / 110V AC, 50 / 60Hz 5V to 200V 0.5V 0sec to 20s 0.01sec 20sec to 100s 0.5sec 100sec to 600s 1.0sec Any 1 or all phases 1V to 100V 0.5V 0sec to 20sec 0.01sec 0sec to 100sec 0.5sec 100sec to 600sec 1.0sec 1V to 100V 0.5V 0sec to 20sec 0.01sec 20sec to 100sec 0.5sec 100sec to 600sec 1.0sec 47Hz to 62Hz. 0.01Hz 0sec to 20sec 0.01sec 20sec to 100sec 0.5sec 100sec to 600sec 1.0sec

DC Digital (status) inputs The basic 2 pole Argus 8 relay contains 4 programmable digital (status) input The basic 3 pole Argus 8 relay contains 1 programmable digital (status) input, with an additional 4 or 8, provided in expanded variants Auxiliary voltage Operating range 30V DC 18-37.5V DC 48V DC 37.5- 60V DC 110/125V DC 87.5-137.5V DC 220/250V DC 175 - 280V DC For relay with 110/125V DC or 220/225V DC auxiliary voltage, a 48 voltage input is supplied for use with external dropper resistors: 110/125V resistor 2K7 5% 2.5W 220/250V resistor 8K2 5% 6.0W Indications User-friendly settings and indications LCD Alphanumeric display for settings, instruments and fault data Environmental Temperature IEC 68-2-1/2 Operating range -10C to +55C Storage range -25C to +70C Humidity IEC 68-2-3 56 days at 40C and 93% relative humidity Vibration IEC 255-21-1 class I Shock and bump IEC 255-21-2 class I Seismic IEC 255-21-3 class I Insulation IEC 255-5 2KVrms for 1 minute between all terminals and earth. 2KVrms for 1 minute between independent circuits. 1KVrms for 1 minute across NO contacts. Transient overvoltage IEC 255-4 class III 5KV 1.2/50s between all terminals and earth without damage or flashover High frequency disturbance IEC 255-22-1 class III 2.5KV common mode < 3% deviation 1.0KV series mode < 3% deviation Electrostatic discharge IEC 255-22-2 class III 8KV direct without maloperation or damage Radio frequency IEC 255-22-3 disturbance 20MHz to 1GHz at 10V/m < 5% deviation Fast transient IEC 255-22-4 class IV 4KV 5/50ns < 3% deviation Mechanical Classification Durability 106 operations

Output phases Negative sequence overvoltage 1, 2 Definite time delay

Neutral voltage displacement 1,2 Definite time delay

Frequency 1,2,3,4 Definite time delay

DC Auxiliary Supply Nominal 24, 30, 48 V 110, 220 V

Operating range 18-60 V 85-280 V

Output relays The basic 2 pole Argus 8 relay contains 7 programmable output relays, 1 of which have 1 CO contact, 1 NC contact and 5 have 1 NO contact The basic 3 pole Argus 8 relay contains 7 programmable output relays, 3 of which have 1 CO contact and 4 have 1 NO contact. Expanded variants provides 4 extra output relays, each having 1 NO contact Contact ratings Carry continuously Make and carry Break

5A AC RMS or DC 30A AC or DC for 0.2sec 75W DC resistive 1250VA AC resistive

Cutout Details

MODULAR CASES: SIZES 4-6


SIZE 4 CASE A 103 B 99.5 C 52 SIZE 6 CASE A 155 B 151 C 103.5

Case Argus 8 - E4 Argus 8 - E6

Weight 3.3 kg 4.8 kg

Ordering Information
Two or three pole Protection requirement (ie voltage or voltage and frequency) Auxiliary digital (status) input voltages No. of output contact and digital (status) input on three pole versions

Qualification
ISO 9001 - 2000
The policy of Easun Reyrolle is one of continuous improvement and development. The company therefore reserves the right to supply equipment, which may differ slightly from that described and illustrated in this publication.

#98, Sipcot Industrial Complex, Hosur 635 126, India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397

#17/3 Arakere, Bannerghatta Road, Bangalore-560 076, India. Tel: +91 80 26581023 / 3268 Fax: +91 80 26580642 Email: blrworks@easunreyrolle.net Ashirwad, #25, 29th Main, 4th B Cross, BTM Layout 2nd Stage, Bangalore-560 076, India. Tel: +91 80 26685496/51311405 Fax: +91 80 26685446 Email: smabp@easunreyrolle.net
AUTOMATION DIVISION EXPORTS DIVISION

SWITCHGEAR WORKS

Ernavur, Chennai-600 057, India. Tel: +91 44 25733715/358 Fax: +91 44 25733468 Email: switchgear@easunreyrolle.net

#17/3 Arakere, Bannerghatta Road, Bangalore-560 076, India. Tel: +91 80 26581023 / 3268 Fax: +91 80 26580642 Email: exports@easunreyrolle.net

Sales Offices
Mumbai

Tel: +91 22 22022270/22855415 Fax: +91 22 22825703 Email: mumbai@easunreyrolle.net


Bangalore

Delhi

Tel: +91 11 25747321/25747322 Fax: +91 11 25747320 Email: delhi@easunreyrolle.net


Chennai

Kolkata

Tel: +91 33 22848320 Fax: +91 33 22848326 Email: kolkata@easunreyrolle.net


Secunderabad

Tel: +91 80 26685496/51311405 Fax: +91 22 26685446 Email: blroffice@easunreyrolle.net


Bhopal

Tel: +91 44 24346425/24347608 Fax: +91 44 24346435 Email: chennai@easunreyrolle.net

Telefax: +91 40 27817847 Email: hyderabad@easunreyrolle.net

Telefax: +91 755 2684221 Email: bhopal@easunreyrolle.net

Corporate Office Easun Reyrolle Limited. 98 Sipcot Industrial Complex Hosur 635 126 India. Tel: +91 4344 401600/01/02 Fax: +91 4344 276397 www.easunreyrolle.com

FACT/ARGUS 8/12-05/Rev 0

HOSUR WORKS

BANGALORE WORKS

You might also like