You are on page 1of 4

%

IEEE 30-BUS TEST SYSTEM


Bus Bus Voltage Angle ---Load---- -------Generator----- Injected
No code Mag.
Degree MW
Mvar MW Mvar Qmin Qmax
Mvar

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
2
0
0
2
0
0
2
0
0
2
0
2
0
0
0
0
0
0
0
0
0
0

1.06
1.043
1.0
1.06
1.01
1.0
1.0
1.01
1.0
1.0
1.082
1.0
1.071
1
1
1
1
1
1
1
1
1
1

0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0
0
0
0

0.0
21.70
2.4
7.6
94.2
0.0
22.8
30.0
0.0
5.8
0.0
11.2
0
6.2
8.2
3.5
9.0
3.2
9.5
2.2
17.5
0
3.2

0.0
12.7
1.2
1.6
19.0
0.0
10.9
30.0
0.0
2.0
0.0
7.5
0.0
1.6
2.5
1.8
5.8
0.9
3.4
0.7
11.2
0.0
1.6

50.0
20.0
0.0
0.0
15.0
0.0
0.0
10.0
0.0
0.0
10.0
0
12.0
0
0
0
0
0
0
0
0
0
0

-30.0
-30.0
0.0
0.0
-15.0
0.0
0.0
-15.0
0.0
0.0
-10.0
0
-15.0
0
0
0
0
0
0
0
0
0
0

0
0
0
0
0
0
0

1
1
1
1
1
1
1
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
150
60
0
0
60
0
0
50
0
0
-40
0
45
0
0
0
0
0
0

0
0
0
0
0
0
0

8.7
0
3.5
0
0
2.4
10.6

6.7
0.0
2.3
0.0
0.0
0.9
1.9

0
0
0
0
0
0
0

0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
19
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

branch data
% %
fbus
angle statu
% linedata=[1
%
1
%
2
%
3
%
2
%
2
%
4
%
5
%
6
%
6

tbus
2
3
4
4
5
6
6
7
7
8

0.0192
0.0452
0.0570
0.0132
0.0472
0.0581
0.0119
0.0460
0.0267
0.0120

x
0.0575
0.1852
0.1737
0.0379
0.1983
0.1763
0.0414
0.1160
0.0820
0.0420

b
0.02640
0.02040
0.01840
0.00420
0.02090
0.01870
0.00450
0.01020
0.00850
0.00450

ratea
1
1
1
1
1
1
1
1
1
1

rateb

ratec

ratio

%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%

6 9 0.0
0.2080
6 10 0
.5560
9 11 0
.2080
9 10 0
.1100
4 12 0
.2560
12 13 0
.1400
12 14
.1231
.2559
12 15
.0662
.1304
12 16
.0945
.1987
14 15
.2210
.1997
16 17
.0824
.1923
15 18
.1073
.2185
18 19
.0639
.1292
19 20
.0340
.0680
10 20
.0936
.2090
10 17
.0324
.0845
10 21
.0348
.0749
10 22
.0727
.1499
21 22
.0116
.0236
15 23
.1000
.2020
22 24
.1150
.1790
23 24
.1320
.2700
24 25
.1885
.3292
25 26
.2544
.3800
25 27
.1093
.2087
28 27
0
.3960
27 29
.2198
.4153
27 30
.3202
.6027
29 30
.2399
.4533
8 28
.0636
.2000
6 28
.0169
.0599
gencost = [1
0.00375 2
2 0.0175
1.75
5 0.0625
1
8 0.0083
3.25
11 0.025
3
13 0.025
3

0.0
1.01550
0
0.96290
0
1
0
1
0
1.01290
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0.95810
0
1
0
1
0
1
0.0214
1
0.065
1];
0 50 200;
0 20 80;
0 15 50;
0 10 35;
0 10 30;
0 12 40];

global busdata linedata gencost


options = gaoptimset;
options = gaoptimset('PopulationSize', 25,'Display','iter','Generations', 100,'S
tallGenLimit',200,'TimeLimit', 300,'StallTimeLimit', 300,'PlotFcns', {@gaplotbe
stf,@gaplotbestindiv});
[x ff]=ga(@opf1,5,options);
From
Sl.No.
To
Tap
(B)pu
X(pu)
R(pu)
MW
[LmFlow
Bus
Ratio
BusLimit
Pgg
vv TL]=opf1(x)
654321

021

1.043
1.06
1.01
1.0

0.0

21.70
94.2
2.4 19.0
7.6
0.0
12.7
1.2
1.6
0.0

50.0
20.0
15.0
0.0 -15.0
-30.0
0.0

0 150
600

You might also like