The Solo T1 DSU/CSU features in-band SNMP management, downloadable software, and optional Frame Relay Management through Integrated Performance Monitoring. With a broad array of diagnostic features, it provides a cost-effective interface between high-speed data terminal equipment (DTE) and public or private T1 networks.

Product Features
x Versatile full or fractional T1 x Standalone or Ensemble WAN Access

network interface
x Software configurable DTE for

System module
x In-band management over frame relay

RS449/EIA-530 or V.35 interface


x Telnet access via comm port or in-band x Local or remote management using

and Cisco HDLC packets


x Non-disruptive downloadable software

for easy upgrades


x Extensive diagnostics include:

an embedded SNMP agent, through Digital Links WANview Network Management System or any commercial SNMP management system
x Integrated Performance Monitoring

Frame Relay management Embedded RMON Probe

Built-in test patterns, test loops and other diagnostic tests Front-panel LEDs Alarm history and event log Test jacks Link-based testing Delay monitoring

Product Overview The Solo T1 is a fully-featured, single data port DSU/CSU that connects routers and other data terminal equipment (DTE) to T1 and Fractional T1 networks. Featuring a softwareconfigurable DTE interface, the Solo T1 DSU/CSU provides an RS-449/EIA-530 or V.35 electrical interface. Bandwidth allocation, also software-configurable, allows you to configure the Solo T1 DSU/CSU for data rates from 56 Kbps up to a full T1 data rate of 1.536 Mbps. With support for industry standard Telnet and SNMP MIB II, the Solo T1 also features a device specific enterprise MIB, which enables configuration, monitoring, and control of all significant operating parameters. With Integrated Performance Monitoring (IPM), comprehensive end-to-end performance monitoring via standard RMON groups allows easier troubleshooting and improved network planning for frame relay networks.

Solo T1 DSU/CSU
VX Encore T1 Access Multiplexer V.35
ncore

T1 DS1 port (optional) T1/FT1

V.35 RS449/EIA-530 Router

T1/FT1
SOLO

Solo T1 DSU/CSU

Wide Area Network

Figure 1: External management access

MAP

SLIP Comm Port

WANview Network Management System

Ethernet

Management Access Processor (or terminal server)

Versatile Device Management Embedded SNMP Agent and External Management The Solo T1 DSU/CSU features an embedded Simple Network Management Protocol (SNMP) agent with the standard Management Information Base (MIB II). It also includes enterprise-wide manageability of network links and unit-specific parameters. You can easily integrate the device-specific enterprise MIB with popular SNMP management packages such as Digital Links WANviewTM Network Management System and HewlettPackards HP OpenView. The Solo T1 DSU/CSU supports RFC 1406, the latest T1 MIB. You can monitor and configure the Solo T1 DSU/CSU through an integral SLIP port, with an ASCII terminal, via a Telnet connection or a dial-up modem. You can also use the Digital Link Management Access Processor (MAP) for Ethernet connection with SLIP access to the Solo T1 DSU/CSU (see Figure 1). In-band Management over Frame Relay and Cisco HDLC protocol The in-band management capability gives you an easy way to manage your Solo T1 DSU/CSU network devices through the data path. You can manage the Solo T1 DSU/CSU by sending management packets through the router connected to the DTE port of the local Solo T1 DSU/CSU unit. You also can manage the remote unit in the same manner because the in-band connection allows you to use the payload portion of the T1 link. Support is available for in-band management over Frame Relay as well as the Cisco HDLC protocol. Using the in-band management feature, you dont need a SLIP connection between the network management station and the Solo T1 DSU/CSU. This eliminates the requirement for a serial cable and for configuring a SLIP port on the NMS station. The in-band management feature offers higher bandwidth for managing both the local and the remote Solo T1 DSU/CSU units. Non-disruptive Downloadable Software A downloadable software function allows you to easily upgrade the Solo T1 DSU/CSU without field visits or changing EPROMs or cards. This download utility supports both XMODEM protocol and Trivial File Transfer Protocol (TFTP). The Solo T1 DSU/CSU stores two images of executable code. The download operation is separate from the switchover to new software, allowing the two operations to be performed at separate times. The unit can be programmed to initialize to new code at a specified time.

Solo T1 DSU/CSU
SOLO

Router

NetScout Manager Plus Router

V.35 RS449/EIA-530
SOLO

T1/FT1 Wide Area Network Solo T1 DSU/CSU

Figure 2: In-band management access

WANview Network Management System

Integrated Performance Monitoring In-band Management Ethernet

Advanced Diagnostic Capability The Solo T1 DSU/CSU offers an extensive suite of diagnostic capabilities for local and remote fault analysis. These include fixed test patterns (e.g., all 1s, all 0s, 1:1, 1:8, 3:24, and QRW) and two user-programmable 24-bit test patterns. The test patterns can be transmitted on the full T1 payload or on the fraction of the payload associated with the DTE port. In addition to front-panel LEDs and test jacks, the Solo T1 DSU/CSU features more than a dozen user-settable alarm parameters and performance thresholds for remote alarm reporting. The Solo T1 DSU/CSU reports these messages to the central site through direct serial connection, a modem connection, or through Digital Links in-band communications link. At the central site, you can display the alarm messages on a printer, terminal, or network management station. Remote Statistics Gathering Communications between the local and remote units using AT&T TR54016, ANSI T1.403, or Digital Link protocols is supported. This enables remote statistics to be gathered and displayed on the local units. Link-based testing and Delay monitoring Link-based testing allows non-intrusive testing of Frame Relay and HDLC networks using ICMP messages to any network addressable unit. In addition, delay monitoring measures and displays the average and maximum network delays experienced by test packets. These features allow network managers to test network links as well as quantify the network delay and are especially useful during network installation and trouble isolation. Frame Relay Performance Monitoring Integrated Performance Monitoring (IPM) provides an embedded probe function to monitor traffic at critical points in the network. Full-time, non-intrusive performance monitoring is available using four standards compliant RMON groups including statistics, history, alarms, and events. Operations can set alarm parameters as well as rising and falling performance thresholds on various frame relay related variables. The Solo T1 with IPM is compatible with NetScout ManagerTM which provides graphical performance statistics for WAN links. The operations manager can use these statistics to verify service level agreements, view trends, and plan capacity tailored to operational needs. In addition, you can monitor the bandwidth utilization to help configure and fine-tune the network (see Figure 2).

Specifications
Network Interface
Products Manufactured Under An ISO 9001 Certified Quality Management System

Diagnostics 1.544 Mbps 50 bps AMI, B8ZS D4, ESF 0, -7.5, or -15 dB LBO DSX-1, 0 to -26 dB Network, DTE or internal Loopback Tests T1 network, T1 payload, fractional T1 payload, fractional DTE, NET/DTE

T1 Line Rate Line Code Framing Output Level

* Lifetime warranty applies to the standalone model only. The shelf-based module has a two-year warranty. The information presented above may change without notice and should be used for informational purposes only. Solo T1 is a trademark of Digital Link. All other product and service names mentioned herein are trademarks of their respective owners.

Input Level System Timing Data Interface Interface Types Data Rates

T1 Loopback Control T1 set/reset codes, ESF FDL per AT&T 54016 and ANSI T1.403, ANSI T1.403 Annex B Test Patterns 1:1, 1:2, 1:4, 1:7, 3:24, QRW, all 0s, all 1s, smart jack, two user-programmable 24-bit patterns, bit error injection

RS449/EIA-530 or V.35, user configurable N x 56/64 Kbps, (N = 1 through 24)

Interface Connectors Network Data Port Comm Port DA15 socket DB25 socket DE9 socket

Network (T1) Alarms Net carrier loss, net sync loss, net AIS received, net yellow received, CRC, BPV, OOF threshold Data Port Alarms Front Panel LEDs RTS loss, DTR loss Power/test, in-band, network status, network loopback, loopback acknowledgment, DTE loopback, TD, RD, CTS, RTS, DTR T1 send, T1 receive Frame Relay and HDLC RMON compliant monitoring for frame relay links

Power Requirements Voltage 100 VAC to 240 VAC, 50/60 Hz and -40 VDC to -78 VDC Bantam Test Jacks Link-based Test Integrated Performance Monitoring Dimensions Width Height Depth Weight Environmental Operating Temp. Storage Temp. Relative Humidity Maximum Altitude Ordering Information Models Feature DL085 DL085-C DL085-C-IB DL085-C-IPM DL2020 DL2120 DL2020-C/DL2120-C DLT1-IPM

Power Consumption 6W maximum Regulatory Compliance FCC Part 15, FCC Part 68 UL 1950 3rd Edition CS-03 DoC VCCI Class 1 CAN/CSA C22.2 No.950-95

8.75 inches (22.2 cm) 1.75 inches (4.4 cm ) 12 inches (30.4 cm) 6.5 lbs (3.0 Kg)

Digital Link Corporation 217 Humboldt Court Sunnyvale, CA 94089 +1.408.745.6200 Phone +1.408.745.6250 Fax email: info@dl.com http://www.dl.com Digital Link Deutschland GmbH Kirchheim/Muenchen, Germany +49.89.9099.630 Phone +49.89.9099.6310 Fax Digital Link UK Ltd. London, England +44.171.244.7660 Phone +44.171.244.6120 Fax

0 to 50 C -20 to +60 C 0 to 95% non-condensing 15,000 feet (4.6 Km)

Solo T1 SNMP managed DSU/CSU with non-volatile configuration retention DL085 with addition of dual image software download capability DL085-C with addition of in-band management, link-based testing, and delay monitoring DL085-C-IB with addition of Integrated Performance Monitoring Solo T1 SNMP managed DSU/CSU module for DL2000 Ensemble WAN Access System with non-volatile configuration retention Solo T1 SNMP managed DSU/CSU module for DL2001 Ensemble WAN Access System with non-volatile configuration retention DL2020/DL2120 module with addition of dual image software download capability Software upgrade adding Integrated Performance Monitoring to DL085-C-IB

1998 Digital Link Corporation Printed in USA. All Rights Reserved 5K/PP/2/98

Printed on recycled paper with soy-based ink.

You might also like