You are on page 1of 23

IN-LINE MIXED FLOW DUCT FANS

TD-MIXVENT Series
Low profile mixed flow fans made of plastic (up to 800 model) or galvanised steel sheet metal protected with epoxy paint (from 1000 model on) and external terminal box. Removable impeller assembly. Speed controllable motor 230V-50Hz, two speed, Class B
(1),

TD-MIXVENT

IP44.
(1)

Models TD-4000 and TD-6000, single speed, Class F.

Additional Information Fitted with single speed non controllable motor. TD-MIXVENT-T models incorporate a Run-OnTimer adjustable within 1 and 30 minutes.

In-Line duct fans

to 350 Models 160

The wide range turns TD-MIXVENT Series into the ultimate solution for all types of ventilation systems either domestic or commercial.

436

Low profile

Classic centrifugal

In-line centrifugal

Ventilation casing

Mixed flow MIXVENT

The low profile of TD-MIXVENT range fans makes them the most effective solution for installations with limited height such as false ceilings.

Easy to mount

Easy maintenance

Fix the support

Place the motor body

Removable motor body allowing maintenance or cleaning without the need to remove any part of the ducting system

Carry the connections out

Couple the ducts

Models with Run-On-Timer

Enables flexible orientation

TD-MIXVENT-T models are fitted with a timer adjustable between 1 and 30 minutes and Can be placed at any part of the air duct are provided with a single speed non-speed controllable motor

437

In-Line duct fans

TD-MIXVENT

Useful applications of the TD-MIXVENT range


The TD-MIXVENT range provides a solution to a large variety of both small and large ventilation installations.

General extract installation

TD-MIXVENT

Localised exhaust point installations

Control panel

In-Line duct fans

Workshop

Parkings

Bread oven

Warm air

Drying installations

TD-800/200N

438

Dried fruit hopper

Drying ceramics tunnel

Residential & Commercial

Screen-printing workshop

Hair salon

Meeting room

Catering

Gym

Childrens dinning hall

Waiting room in a health care center

Domestic kitchen extract hood

439

In-Line duct fans

TD-MIXVENT

Design characteristics
160 Polypropylene casing Steel casing ABS impeller 250 350 500 800 800N 1000 1300 2000 4000 6000


II


II


II


II

TD-MIXVENT

Aluminium impeller Protection class Thermal protection by fuse Self- resetting thermal protection Ball bearings greased for life 1 speed controllable motor 2 speed controllable (*) motor
(*) Models with Run-On-Timer fitted (TD-MIXVENT-T) are not controllable.

II

II

In-Line duct fans

Technical characteristics
Speed Maximum power absorbed (W) 20 12
24 18 30 22 50 44 50 44 70 60 120 100 125 85 180 140 255 160 345 665

TD-MIXVENT TD-160/100 N SILENT


TD - 250/100 TD - 350/125 TD- 500/150 TD- 500/160 TD- 800/200N TD- 800/200 TD-1000/250 TD - 1300/250 TD-2000/315 TD-4000/355 TD-6000/400

(r.p.m.) 2500 2200


2200 1850 2250 1900 2500 1950 2500 1950 2780 2480 2500 2000 2800 2610 2520 2000 2700 2000 1400 1400

Maximum absorbed current (A) 0,16 0,10


0,11 0,10 0,13 0,10 0,22 0,19 0,22 0,19 0,30 0,26 0,50 0,45 0,50 0,35 0,80 0,60 1,20 0,80 1,53 2,97

Airflow at free discharge (m3/h) 180 140


240 180 360 280 580 430 580 430 880 700 1100 800 1010 900 1300 1100 2000 1550 3800 5500

Maximum operating temperature (C) 40 40


40 40 40 40 60 60 60 60 60 60 60 60 60 60 60 60 60 60 40 40

Sound pressure level* (dB(A)) 24 21


31 26 33 28 33 29 33 29 37 33 39 33 40 38 43 39 47 42 44 44

Duct (mm) 100 100 125 150 160 200 200 250 250 315
355 400

Weight

(kg) 1,4 2,0 2,0 2,7 2,7 4,9 4,9 9,4 9,4
14,0 19,0 26,0

*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

Speed

TD-MIXVENT-T TD-160/100 NT SILENT


TD - 250/100 T TD - 350/125 T TD- 500/ 150 T TD- 500/ 160 T TD- 800/200 T

(r.p.m.) 2500
2200 2250 2500 2500 2500

Maximum power absorbed (W) 20


24 30 50 50 120

Maximum absorbed current (A) 0,16


0,11 0,13 0,22 0,22 0,50

Airflow at free discharge (m3/h) 180


240 360 580 580 1100

Maximum operating temperature (C) 40


40 40 60 60 60

Sound pressure level* (dB(A)) 24


31 33 33 33 39

Duct (mm) 100


100 125 150 160 200

Weight

(kg) 1,4
2,0 2,0 2,7 2,7 4,9

*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

440

Acoustic power spectrum in dB(A), for every frequency band, at the inlet and radiated, at high speed
AT INLET TD-160/100 N SILENT TD-250/100 TD-350/125 TD-500/150 TD-500/160 TD-800/200N TD-800/200 TD-1000/250 TD-1300/250 TD-2000/315 TD-4000/355 TD-6000/400 RADIATED TD-160/100 N SILENT TD-250/100 TD-350/125 TD-500/150 TD-500/160 TD-800/200N TD-800/200 TD-1000/250 TD-1300/250 TD-2000/315 TD-4000/355 TD-6000/400 63 24 28 35 32 32 37 37 35 37 41 40 43 63 24 27 33 25 25 26 29 23 22 29 31 30 125 32 47 47 35 35 42 47 45 52 57 49 56 125 24 46 46 32 32 32 36 34 36 41 49 53 250 39 46 46 55 55 62 61 58 64 66 61 67 250 37 45 46 43 43 48 47 44 39 52 55 59 500 46 53 53 57 57 64 63 66 67 71 66 72 500 34 44 47 39 39 47 46 46 47 55 55 55 1000 52 52 54 59 59 66 68 72 75 77 73 76 1000 36 43 47 44 44 52 54 58 60 64 63 61 2000 49 47 50 62 62 64 67 69 73 74 70 74 2000 41 43 45 53 53 53 57 57 59 63 57 55 4000 40 39 41 56 56 60 64 62 66 67 66 69 4000 32 32 33 42 42 44 48 46 52 57 51 54 8000 21 33

48 48 52 54 54 61 62 57

8000 21 25 24 29 29 31 33 43 47 53 40 45

Dimensions (mm)
TD -160/100 N SILENT TD -250 a TD-2000 TD -4000 / TD-6000

Model TD - 250/100 TD - 350/125 TD - 500/150 TD - 500/160 TD - 800/200N TD - 800/200 TD -1000/250 TD -1300/250 TD -2000/315 Model TD - 4000/355 TD-6000/400

X 188 188 212 212 232,5 232,5 291 291 356 A 377 407

A 303 258 295 275 302 302 386 386 450 B 238 249 C 451 492

B 176 176 200 200 217 217 272 272 336

C 115 115 127 127 141 141 192 192 224 D 224 267 E 426 487

97 123 147 157 198 198 248 248 312 F 354 399

E 100 100 112 112 124 124 155 155 188 G 150 160 H 368 425

F 90 90 130 130 140 140 168 168 210 I 474 547

G 80 80 80 80 100 100 145 145 182 J 340 370

H 60 60 60 60 94 94 140 140 178 K 8.5 8.5

Accessories (see pages from 527 to 546)


441

In-Line duct fans

60

TD-MIXVENT

33

Performance curves
HS = High speed Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. LS = Low speed Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pe mmWG

TD-MIXVENT

Pa

HS LS

In-Line duct fans

Pa

Pe mmWG

Pa

Pe mmWG

HS LS LS

HS

Pa

Pe mmWG

Pa

Pe mmWG

HS

HS

LS

LS

442

Performance curves
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pe mmWG Pe mmWG

HS HS LS

LS

Pa

Pe mmWG

Pa

Pe mmWG

HS LS LS

HS

Pa

Pe mmWG

Pa

Pe mmWG

443

In-Line duct fans

TD-MIXVENT

Pa

Pa

MIXVENT KITS
The TD Extraction Kits of the MIXVENT Series are assemblies of accessories plus fan designed for the ventilation of small rooms such as bathrooms, toilets or utility rooms.

TD-MIXVENT In-Line duct fans

There are 3 Kit models available KIT TD-160/100 N SILENT Which include: 1 TD-160/100 N SILENT fan
+ 4m flexible duct GSA / flexible aluminium ducting + 1 Circular air valve BOR-100/ interior circular air valve + 1 inlet guard GR-100 / exterior mounted grille + 1 adhesive duct tape / roll of tough ducting tape

KIT TD-250/100 Which include: 1 TD-250/100 fan


+ 4m flexible duct GSA + 1 Circular air valve BOC-100 + 1 inlet guard GR-100 + 1 adhesive duct tape BA
TD-160/100 N SILENT TD-250/100 TD-250/100T

Installation and mounting

KIT TD-250/100T Which include: 1 TD-250/100 T fan


+ 4 m flexible duct GSA + 1 Circular air valve BOC-100 + 1 inlet guard GR-100 + 1 adhesive duct tape BA
BOR-100

GR-100

The TD-250 T extractor is fitted with a Run-OnTimer adjustable between 1 and 30 minutes, keeping the fan in operation for the selected period of time after being switched off.

Accessories included
GSA-100 Flexible circular aluminium duct of 100 mm diameter. 4 m long. GR-100 External guard BOR-100 Circular air valves

BA-50 Adhesive aluminium duct tape to fix the elements that compound the extraction remote kits (duct, flange, hood and extractor), 5 m long.

444

TD Series MIXVENT-TD System


S&P has designed MIXVENT-TD system to provide a wide range of solutions based on fans from TD range, maintaining the concept that makes the difference: deliver the maximum airflow using the minimum space.

MIXVENT-TDx2 and MIXVENT-TDx3 Increase of pressure

MIXVENT-TWIN Double airflow

MIXVENT-TWINx2 Increase of pressure and double airflow

445

In-Line duct fans

TD-MIXVENT

MIXVENT-TDx2
System specially recommended when the fan has the suitable airflow, but an increase of the pressure is required due to the high pressure drop. MIXVENT-TD x 2 system is a standard catalogue product from 350 to 1300 model.

TD-MIXVENT In-Line duct fans

A TDx2 can also be obtained coupling 2 TD model fans using a flange MBR (see the accessories section).

Technical characteristics
Speed Maximum absorbed power (W)
60 44 100 88 140 120 240 200 250 170 360 280

Maximum current (A)


0,26 0,20 0,44 0,38 0,60 0,52 1,00 0,90 1,00 0,70 1,60 1,20

MIXVENT-TDx2
TD x2- 350/125
150 TDx2- 500/ 160

(r.p.m.)
2250 1900 2500 1950 2780 2480 2500 2000 2800 2610 2520 2000

Duty at free discharge (m3/h)


395 320 580 475 880 690 1020 790 1020 900 1320 980

Maximum operating temperature (C)


40 40 60 60 60 60 60 60 60 60 60 60

Sound pressure level* (dB(A))


36 31 48 41 48 44 52 48 57 51 57 52

Weight

(kg)
5,4 5,0 8,7 8,7 18,7 18,7

TDx2- 800/200N TDx2- 800/200 TDx2-1000/250 TDx2- 1300/250

*Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet.

Dimensions (mm)
X E

MIXVENT-TDx2

X 188,0 212,5 212,5 232,5 291,0 291,0

A 417 464 444 500 654 654

C 115 127 127 141 192 192

E 100

F 90

G 253 249 249 298 416 416

H 60 60 60 94 145 145

5,5
C

TDx2-350/125 TDx2-500/150 TDx2-500/160

176 200 200 217 272 272

123 147 147 198 248 248

111,5 130 111,5 130 124 155 155 140 168 168

TDx2-800/200
D B

G A

TDx2-1000/250 TDx2-1300/250

Acoustic power spectrum in dB(A) for every frequency band at the inlet and radiated, at a high speed.
AT THE INLET TDx2-350/125 TDx2-500/150 TDx2-500/160 TDx2-800/200N TDx2-800/200 TDx2-1000/250 TDx2-1300/250 63 41 38 38 43 43 41 43 125 53 41 41 48 53 51 58 250 52 61 61 68 67 64 70 500 59 63 63 70 69 72 73 1000 2000 4000 8000 60 65 65 72 74 78 81 56 68 68 70 73 75 79 47 62 62 66 70 68 72 39 54 54 58 60 60 67 RADIATED TDx2-350/125 TDx2-500/150 TDx2-500/160 TDx2-800/200N TDx2-800/200 TDx2-1000/250 TDx2-1300/250 63 39 31 31 32 35 29 28 125 52 38 38 38 42 40 42 250 52 49 49 54 53 50 45 500 1000 2000 4000 8000 53 45 45 53 52 52 53 53 50 50 58 60 64 66 51 59 59 59 63 63 65 39 48 48 50 54 52 58 30 35 35 37 39 49 53

446

Performance curves
Q = Air volume in, m3/hr and m3/s. HS = High speed Pe = Static pressure in mmWG and Pa. LS = Low speed Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.
Pe mmWG Pe mmWG

Pa

Pa

HS

HS

LS

LS

Pa

Pe mmWG

Pa

Pe mmWG

HS HS LS LS

Pa

Pe mmWG

Pa

Pe mmWG

HS HS LS LS

447

In-Line duct fans

TD-MIXVENT

MIXVENT-TDx3
System specially recommended when the fan has the suitable airflow but an increase of the pressure is required due to the very high pressure drop. A MIXVENT-TD x 3 can be obtained coupling a MIXVENT-TD x 2 model with a TD fan using an

TD-MIXVENT

MBR flange. Technically more units could be installed in series to increase the pressure but it is recommended to carry out a study before.

MIXVENT-TDx3 design
MIXVENT-TDx3 Composition

In-Line duct fans

TDx3-350/125 TDx3-500/150 TDx3-500/160 TDx3-800/200 TDx3-1000/250 TDx3-1300/250

TD-350/125+TDx2-350/125+MBR-350 TD-500/150+TDx2-500/150+MBR-500/150 TD-500/160+TDx2-500/160+MBR-500/160 TD-800/200+TDx2-800/200+MBR-800 TD-1000/250+TDx2-1000/250+MBR-1000 TD-1300/250+TDx2-1300/250+MBR-1000

1 single fan operating

Performance curves

Airflow direction

A must work

MBR flange

Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

1 2 3 4 5

TD x 3-350 TD x 3-500 TD x 3-800 TD x 3-1000 TD x 3-1300

MBR flange

2 fans operating

Pe Pa A B C mmWG

MBR flange A and B or A and C must operate

Airflow direction

Dimensions (mm)

G2 A

G1

MIXVENT-TDx3 TD x 3-350/125 TD x 3- 500/150 TD x 3- 500/160 TD x 3- 800/200 TD x 3- 1000/250 TD x 3- 1300/250

A 755 766 726 801 1055 1055

G1 80 80 80 100 145 145

G2 253 249 249 298 416 416

L 213 223 203 207 246 246

448

MIXVENT-TWIN
System specially recommended when a large airflow is required within a confined space, or where a supplementary airflow is occasionally needed. It is also needed in installations where it is necessary to mount a twin fan extraction - supply system, with the same characteristics. MIXVENT-TWIN system can be mounted by the installer using fans in series. Therefore, it is necessary a kit (KIT TWIN BASE) which allows a parallel mounting of two TD of the same model (suitable from 250 to 2000 model). Once mounted, the whole assembly is ready, fitted with inlet and outlet flanges, to be connected to a rectangular duct. If the fans are not need to operate simultaneously it is recommended to mount backdraft shutters to avoid the backdraft of air when the fan is disconnected.
MIXVENT-TWIN system

MIXVENT-TWIN system with backdraft shutter fitted

Accessories to mount MIXVENT-TWIN system


KIT TWIN BASE-250 + 2 TD -160/100 KIT TWIN BASE-250 + 2 TD 250/100 KIT TWIN BASE-350 + 2 TD -350/125
Backdraft shutter, see accessories page.

KIT TWIN BASE-500/150 + 2 TD-500/150 KIT TWIN BASE-500/160 + 2 TD-500/160 KIT TWIN BASE-800 + 2 TD-800/200

KIT TWIN BASE-1000 + 2 TD-1000/250 KIT TWIN BASE-1000 + 2 TD-1300/250 KIT TWIN BASE-2000 + 2 TD-2000/315

KIT TWIN BASE


It is constituted by two rectangular couplings of normal dimensions and two supports allowing the mounting of two TD or two TD x 2 models in parallel.
KIT TWIN BASE KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000 Dimensions (mm) L H 320 180 320 180 395 220 395 220 440 240 540 290 690 355 Nominal dimensions of the rectangular duct (mm) L H 280 140 280 140 355 180 355 180 400 200 500 250 630 315
Due to the isolated operation of TD models, backdraft shutters mounted at the outlet of TD fans is required in order to avoid the backdraft of air when the fan is disconnected.

449

In-Line duct fans

TD-MIXVENT

Dimensions (mm)

TD-MIXVENT

E B
"

O L

O2 L2

Model Twin-250 Twin-350 Twin-500 (150)

A 320 320 395 395 440 540 540 690

B 180 180 220 220 240 290 290 355

C 184 184 206 206 225 282 282 347

D 36 33,5 37 37 37 44 44 53

E 160 160 200 200 220 270 270 335

F 300 300 375 375 420 520 520 650

L 305 305 310 290 317 401 401 451

L2 475 481 461 509 679 679

M 375 333 417 417 456 566 566 699

N 113 91 110 100 103 123 123 136

O 80 80 80 80 100 145 145 182

O2 253 249 249 298 416 416

In-Line duct fans

Twin-500 (160) Twin-800 Twin-1000 Twin-1300 Twin-2000

Performance curves
Q = Air volume in, and Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. m3/hr m3/s.

1 2 3 4 5

Twin 350 Twin 500 Twin 800 Twin 1000 Twin 1300

Twin x 2-350 Twin x 2-500 Twin x 2-800 Twin x 2-1000 Twin x 2-1300

Acoustic power spectrum in dB(A) for every frequency band at the inlet and radiated, at a high speed
AT THE INLET TWIN-350/125 TWIN-500/150 TWIN-500/160 TWIN-800/200N 63 38 35 35 40 40 38 40 44 125 50 38 38 45 50 48 55 60 250 49 58 58 65 64 61 67 69 500 56 60 60 67 66 69 70 74 1000 57 62 62 69 71 75 78 80 2000 53 65 65 67 70 72 76 77 4000 44 59 59 63 67 65 69 70 8000 36 51 51 55 57 57 64 65

Pe Pa mmWG TWIN-800/200 TWIN-1000/250 TWIN-1300/250 TWIN-2000/315

RADIATED TWIN-350/125 TWIN-500/150 TWIN-500/160 TWIN-800/200N TWIN-800/200 TWIN-1000/250 TWIN-1300/250 TWIN-2000/315

63 36 28 28 29 32 26 25 32

125 49 35 35 35 39 37 39 44

250 49 46 46 51 50 47 42 55

500 50 42 42 50 49 49 50 58

1000 50 47 47 55 57 61 63 67

2000 48 56 56 56 60 60 62 66

4000 36 45 45 47 51 49 55 60

8000 27 32 32 34 36 46 50 56

450

MIXVENT-TWINx2
System specially recommended when a higher airflow and pressure is required within a reduced space. MIXVENT-TWIN x 2 system can be mounted by the installer using fans in series. Therefore, it is necessary to use a kit (KIT TWIN BASE) which allows a parallel mounting of two TD x 2 of the same model (suitable from 350 to 1000 model). Once mounted, the whole assembly is ready with flanges at the inlet and at the outlet, to be connected to a rectangular duct. If the fans do not need to operate simultaneously it is recommended to mount backdraft shutters to avoid the backdraft of air when the fan is not operating.
MIXVENT-TWINx2 system

Elements to mount MIXVENT-TWIN x 2 system


KIT KIT KIT KIT KIT KIT TWIN TWIN TWIN TWIN TWIN TWIN BASE-350 + 2 TDx2-350/125 BASE-500/150 + 2 TDx2-500/150 BASE-500/160 + 2 TDx2-500/160 BASE-800 + 2 TDx2-800/200 BASE-1000 + 2 TDx2-1000/250 BASE-1000 + 2 TDx2-1300/250

MIXVENT-TWINx2 system with backdraft shutter fitted

Performance curves
Q = Air volume in, m3/hr and m3/s. Pe = Static pressure in mmWG and Pa. Dry air at 20C and 760 mmHg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

1 2 3 4 5

Twin 350 Twin 500 Twin 800 Twin 1000 Twin 1300

Twin x 2-350 Twin x 2-500 Twin x 2-800 Twin x 2-1000 Twin x 2-1300

Backdraft shutter, see accessories page.

KIT TWIN BASE


It is fitted with two rectangular couplings of normal dimensions and two supports allowing the mounting of two TD or two TD x 2 models in parallel.
Pe Pa mmWG

KIT TWIN BASE

Dimensions (mm) L H 180 180 220 220 240 290 355

Nominal dimensions of the rectangular duct (mm) L 280 280 355 355 400 500 630 H 140 140 180 180 200 250 315

KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000

320 320 395 395 440 540 690

Due to the isolated operation of TD models, backdraft shutters mounted at the outlet of TD fans are required in order to avoid the backdraft of air when the fan is not operating.

451

In-Line duct fans

TD-MIXVENT

MIXVENT HEATING System (TD-MIXVENT + MBE battery)


The MIXVENT heating system offers the most economic solution for the heating of fresh air supply systems. The MIXVENT HEATING system is created basi-

TD-MIXVENT

cally by a TD-MIXVENT fan in series (from 250 model) which is then directly connected with an electrical heater battery at the outlet from MBE series, specially designed to provide the maximum performance with the minimum pressure drop. Minimum airflow speed within the battery should be 1.5 m/s. TD-MIXVENT The batteries are fitted with: - Armoured heating elements. MBE Electrical heater battery

In-Line duct fans

- Automatic safety thermostat connected in series with another safety thermostat (RESET). Units are prewired to connect to single phase (models 100, 125 and 160) or three phase (other models), with a protection circuit supplied on 230V single phase models. - Connection box IP43. The installation can be completed with duct or ambient temperature sensors and speed controllers, obtaining an air delivery with the temperature according to the environmental requirements. With this system it is possible to achieve a temperature rise of 50 on the supply air.
4000/355 6000/400 MBE-355/90T MBE-400/120T 9000 12000 3/400 3/400 570 570 TTC-2000 TTC-2000 250/100 350/125 500/160 800/200 1000-1300/250 2000/315 TD-MIXVENT MBE battery type MBE-100/04B MBE-125/12B MBE-160/21B MBE-200/50T MBE-250/60T MBE-315/90T Battery power (W) 400 1200 2100 5000 6000 9000 Batteries supply 1/230 1/230 1/230 2/400 2/400 3/400 Minimum airflow (m3/s) 50 70 110 170 270 420 Speed controller type PULSER PULSER PULSER PULSER PULSER TTC-2000

SELECTION EXAMPLE DATA: Airflow: 700 m3/h (Q) Input air temperature: +5 C Required output temperature: +27 C In those installations where MIXVENT HEATING system is required it is convenient to use filter boxes MFL to protect the electrical P = Q x 0,36 x T = 700 x 0,36 x 22 = 5544 W batteries from the debris.

REQUIRED HEAT POWER:

BATTERY ELECTION Or: MBE-200/50T Or: MBE-250/60T Final election will depend of: Total pressure drop Desired sound level Available space

Difference of temperature between external and internal air T (C)

452

Battery pressure drop p (Pa)

Dimensions (mm)

MBE heater batteries accessories


PULSER controller Electronic controller for electrical heater batteries. To install in the room that needs to be heated. Depending on the selected temperature, the controller will activate the battery to maintain that temperature in the whole installation. TTC-2000 controller Electronic controller for three phase electrical heater batteries to 16,5 kW. For those higher, module TTS-1* (up to 30 kW) must be connected. TTC-2000 controls the time of operation of the three phase electrical batteries. TTC-2000 is designed to be mounted in standard board and has to be connected at a temperature sensor placed on the room to be heated or in the heat air duct. Power 50 kW. * The module TTS-1 is an electronic plate to place in TTC-2000

Dimensions LxAxH (mm): 92x45x150

Dimensions LxAxH (mm): 160x140x280

Temperature sensor TG-R530 To place in the ambient to be heated: NTC type with linear scale Operating temperature: 0 -30C IP-20 Suitable for the controllers type TTC-2000 controlling MBE or IBE batteries.

Sensor TG-K330 Temperature sensor to place in the heating air duct. NTC type with linear scale Operating temperature: 0 -30C IP-20 Suitable for controllers type TTC-2000 , controlling MBE or IBE batteries.
5 30 40
9

Dimensions LxAxH (mm): 70x30x70

140

453

In-Line duct fans

TD-MIXVENT

Wiring diagrams for MBE electric batteries


WIRING DIAGRAM E10 ELECTRIC HEATER BATTERY TYPE: MBE100/04B MBE125/12B MBE160/21B A B C D E F : : : : : : HEATING ELEMENTS AUTO-RESET THERMAL PROTECTION MANUAL-RESET THERMAL PROTECTION PULSER (REG 16) (MX. 3,2 KW 320V) SWITCH ELECTRICAL LINE PROTECTION

In-Line duct fans

TD-MIXVENT

WIRING DIAGRAM E20 ELECTRIC HEATER BATTERY TYPE: MBE200/50T MBE250/60T A B C D E F G H : : : : : : : : heating elements auto-reset thermal protection manual-reset thermal protection PULSER (REG 6) (Mx. 6 kW 400V) switch contactor electrical line protection optional temperature sensor (ducted 1G-K330 or ambient TG-R530)

WIRING DIAGRAM E30 ELECTRIC HEATER BATTERY TYPE: MBE315/90T A B C D F G H : : : : : : : heating elements auto-reset thermal protection manual-reset thermal protection TTC-2000 contactors electrical line protection optional temperature sensor (ducted TG-K330 or ambient TG-R530)

454

MIXVENT FILTER System (TD-MIXVENT + Filter box MFL)


The MIXVENT Filter systems are used when the installation requires the supply of fittered clear air. MIXVENT FILTER system is made of a standard TD-MIXVENT fan (from model 250 on), and a filter box from MFL series. MFL filter boxes are of EU3 and Gravimetric type, with filter efficiencies of between 80 and 95% of the particles higher than 10 microns.

TD-MIXVENT Filter box MFL

A usual application of MFL filter boxes is to protect the electrical batteries from the dirt, in those installations where MIXVENT HEATING is used.

Dimensions (mm)
E F

D B

MFL filter boxes are fitted with an easy acces cover to change the filter quickly.

Model MFL-100 MFL-125 MFL-160 MFL-200 MFL-250 MFL-315 MFL-355 MFL-400

A 200 200 200 243 293 342 447 447

B 200 200 200 244 294 343 448 448

D 100 125 160 200 250 315 355 400

E 160 160 154 154 154 154 154 154

F 196 196 196 202 206 206 254 254

Pressure drop of the filter boxes p (Pa)

455

In-Line duct fans

TD-MIXVENT

TD-MIXVENT Mounting accessories


Specific accessories for TD Series
MCA Backdraft shutters to install at the outlet of the fans preventing the entry of outdoors or external air and avoiding heat leaks when the fan is not in use. To apply in TD, TD x 2, TD x 3 and TWIN model series.
B D

TD-MIXVENT

A C

MCA-250 to 2000 Model MCA/JCA MCA - 250 MCA - 350 MCA - 500/150 MCA - 500/160 MCA - 800 MCA - 1000 MCA - 2000 MCA - 4000 MCA - 6000 Type of TD - TDx2 - TDx3 - TWIN 160/100N - 250/100 350/125 500/150 500/160 800/200 - 800/200N 1000/250 - 1300/250 2000/315 4000/355 6000/400 Model MCA MCA - 250 MCA - 350 MCA - 500/150 MCA - 500/160 MCA - 800 MCA - 1000 MCA - 2000 MCA - 4000 MCA - 6000 A 107 107 121 121 131,5 164 205 265 307

MCA-4000/6000 B 111 136 163,5 173,5 214 264,5 330 374 419 C 31,5 31,5 35 35 35 42 50 55 65 D 94,5 119,5 147 157 197,5 248 312 354 399

In-Line duct fans

MAR Rectangular Duct Adapter enables TD, TD x 2 and TD x 3 model series to be mounted on rectangular ducting.

F A C

C 33,3 33,5 37 37 37 42 52 E 160 160 200 200 220 270 355

Model MAR

Type of TD-TDx2-TDx3

Nominal dim. of ducting L x H


224 x 140 224 x 140 280 x 180 280 x 180 315 x 200 400 x 250 500 X 315

Model MAR MAR - 250 MAR - 350 MAR - 500/150 MAR - 500/160 MAR - 800 MAR - 1000 MAR - 2000

A 264 264 320 320 355 440 540

B 180 180 220 220 240 290 355

F 244 244 300 300 335 420 520

G 9 9 9 9 9 9 9

MAR - 250 160/100N - 250/100 MAR - 350 350/125 MAR - 500/150 500/150 MAR - 500/160 500/160 MAR - 800 800/200-800/200N MAR - 1000 1000/250-1300/250 MAR - 2000 2000/315

MRJ Guards to mount either at the inlet of the fan or at the outlet. Avoiding the entry of foreign objects that could damage the fan. To apply at TD, TD x 2, TD x 3 and TWIN model Series.

Model MRJ MRJ - 250 MRJ - 350 MRJ - 500/150 MRJ - 500/160 MRJ - 800 MRJ - 1000 MRJ - 2000 MRJ - 4000 MRJ - 6000

Type of TD - TDx2 - TDx3 - TWIN 160/100N - 250/100 350/125 500/150 500/160 800/200 - 800/200N 1000/250 - 1300/250 2000/315 4000/355 6000/400

456

MBR Flanges allowing the coupling of TD fans in series.

Model MBR MBR-350 MBR-500/150 MBR-500/160 MBR-800 MBR-1000

of the duct 125 150 160 200 250

KIT TWIN BASE Is fitted with two rectangular connectors and two supports allowing the mounting of two TD or two TD x 2 in parallel.

KIT TWIN BASE KIT TWIN BASE 250 KIT TWIN BASE 350 KIT TWIN BASE 500/150 KIT TWIN BASE 500/160 KIT TWIN BASE 800 KIT TWIN BASE 1000 KIT TWIN BASE 2000

Dimensions (mm) L 320 320 395 395 440 540 690 H 180 180 220 220 240 290 355

Nominal dim. of rectangular duct (mm) L 280 280 355 355 400 500 630 H 140 140 180 180 200 250 315

General mounting accessories


SIL Sound attenuators
"

Model SIL 125 SIL 160 SIL 200 SIL 250 SIL 315 SIL 355 SIL 400

A (mm) 125 160 200 250 315 355 400

B (mm) 250 250 315 355 400 450 500

C (mm) 700 700 700 700 700 700 700

D (mm) 900 900 900 900 860 860 860

125 5 9 8 6 2,2 4,1 3,1

250 13 14 11 10 3,3 6,7 4

Attenuation in dB 500 1000 2000 21 37 37 23 25 17 23 25 17 19 25 16 9 21,2 7,6 13,2 14,3 3,4 9,5 13,7 5,6

4000 31 9 9 7 4,1 8,1 0,4

SIL sound attenuator mounted together with a TD-MIXVENT, a filter box MFL and a heat electrical battery MBE

457

In-Line duct fans

Due to the independent operation of TD models, backdraft shutters mounted at the outlet of TD fans are required in order to avoid the backdraft of air when the fan is disconnected.

TD-MIXVENT

Mounting general accessories


GSA Flexible ducts GSI Acoustic ducts CX Worm drive clips

TD-MIXVENT

PER-W Outdoor plastic louvre shutters

BOC Circular air valves

RED Reducer

MRT Joining piece

CT Cowl

In-Line duct fans

GRA Aluminium supply air guards

GRI Internal guards painted in extruded aluminium.

RP Plenums for the supply of air in ceiling voids.

GCI Circular diffusers

Electrical accessories
REGUL 2 2 Speed switches REB Single-phase electronic speed controller RMB Single-phase autotransformer speed controller

458

You might also like