Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
RELEASE NOTE FOR NEMO ANALYZE 5.13 1 2 Introduction New Features 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 3 4 Support for Nemo File format version 2.01 CSV (Character Separated Value) ASCII import to database (optional) Extended line drawing to base station on map Base station colouring based on custom parameters on map Workbook report templates Fleet manager improvements KPI workbench improvements New CDMA/EVDO KPIs New troubleshooting KPIs New search folder options Improvements in TEMS support Improved search functionality in the grid Other improvements Fixed problems
Computer Hardware and Software Requirements Installation 4.1 4.2 4.3 4.4 First-time installation Update/ Upgrade from versions 5.11 and 5.12 Update/ Upgrade from versions 5.06, 5.07, and 5.10 Update/ Upgrade from version 5.05 or older
5 6
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
1 Introduction
Nemo Analyze 5.13 is a powerful and versatile, cutting-edge analysis tool for performing benchmarking, troubleshooting and statistical reporting based on drive test data. The system scales from a standalone tool to an enterprise-level client/server solution and incorporates an innovative, low-maintenance database engine that has been designed and optimized specifically for high-performance postprocessing of drive test data. Nemo Analyze helps you to streamline your processes by enabling you to automate the entire data processing chain from a drive test to an open workbook with analysis results. Nemo Analyze offers a comprehensive set of technology-specific Key Performance Indicators for the latest wireless technologies and a wide range of data views that are known to offer the best visualization of drive test data on the market - and yet it is highly cost effective, easy to set up and use, and it scales to meet the needs of organizations of any size. Nemo Analyze offers support for all major wireless technologies, including TDMA, AMPS, cdmaOne, GSM, HSCSD, GPRS, EDGE, WCDMA, HSDPA, CDMA2000, TETRA, TETRAPOL, DVB-H, UMA, HSUPA, TD-SCDMA, and WiMAX. Supported measurement file formats include Nemo, Ericsson TEMS, EADS REMS TETRAPOL, and character-separated value (CSV).
2 New Features
This chapter lists new features and problem fixes in Nemo Analyze 5.13. Examples and instructions for the most important new features are included.
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
When importing data, various settings need to be made, such as defining the columns to be imported and the columns that define time, latitude, longitude, and other special columns necessary for data visualization. These settings can be saved as a template which allows all files of the defined kind to be automatically loaded into the database. When a CSV template is created, a corresponding table structure is automatically created into the database for the purpose of storing all files of the defined kind. New CSV templates are created from the menu: File Tools Database manager CSV Templates Right-click Add template (See picture below).
After the template has been created, files of the defined type can be loaded into the database in the same way as standard Nemo log files (See picture below)
Loaded CSV files are displayed on the CSV files page of the workspace. When a file is selected in the workspace, the columns of the file are displayed as parameters in the Parameter Tree below. The parameters can be visualized in the same way as with Nemo log files. See the picture below.
4
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Picture 6. Map plot with BTS icon colour coding based on cells measured by the mobile
7
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Each template contains multiple pages with PS and CS statistics, system distribution, log file listing, all failure events, and statistics and map plots of RF parameters. Some examples of the reports are shown in the pictures below.
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Picture 9. Ec/N0 best active set page of the UMTS workbook report
Picture 10. RRC state and spreading factor page of the UMTS workbook report
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Another improvement is in the KPI workbench filter node. It is now possible to create filters with multiple AND/OR statements with parenthesis. See picture below for example.
10
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
12
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
UMTS to GSM missing neighbour analysis produces a list of all unique pairs of serving UMTS cell missing GSM neighbour cell found from the measurement data. For each missing neighbour case, serving cell Ec/N0, missing cell Rx level, elapsed time (the length in time the missing neighbour occurrence has been evident in the measurement data), and the distance from the route to the missing cell antenna are returned. With Nemo Analyze Professional it is also possible to drill down from each case to see the situation on the map.
Problem events KPI lists all problem events (dropped calls, failed handovers, location area update failures, etc.) found from the measurement data. The KPI can be visualized as a grid, or on a map as a colour-coded route and/or print value.
13
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
Picture 20. Adding search folder to retrieve previously uploaded or measured log files
14
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
15
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
4 Installation
4.1 First-time installation
Note that for both Windows XP and Windows Vista, the installation must be run under Administrator account or other user account with administrative privileges.
16
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
1. Install Nemo Analyze 5.13 by running the setup. Follow the instructions of the setup wizard. Restart the computer after installation if required by the setup wizard.
2. Uninstall previous version of Nemo Analyze from Control Panel Add or Remove programs, NOT by running the Nemo Analyze 5.13 setup. Restart computer if required by the setup wizard 3. Install Nemo Analyze 5.13 by running the setup. Follow the instructions of the setup wizard. Restart the computer after installation if required by the setup wizard.
4. Uninstall previous version of Nemo Analyze from Control Panel Add or Remove programs, NOT by running the Nemo Analyze 5.13 setup. Restart computer if required by the setup wizard 5. Install Nemo Analyze 5.13 by running the setup. Follow the instructions of the setup wizard. Restart the computer after installation if required by the setup wizard. 6. Failed to connect to database error may appear when starting Nemo Analyze first time after the installation. In that case, close Analyze.exe, and AnalyzeSocketServer.exe processes from the Windows Task Manager, and run C:\Nemo Tools\Nemo Analyze Datastore\remove database.bat.
1. Uninstall previous version of Nemo Analyze from Control Panel Add or Remove programs, NOT by running the Nemo Analyze 5.13 setup. Restart computer if required by the setup wizard
17
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo
2. Run C:\Nemo Tools\Nemo Analyze Datastore\remove database.bat. 3. Install Nemo Analyze 5.13 by running the setup. Follow the instructions of the setup wizard. Restart the computer after installation if required by the setup wizard.
5 Compatibility
Nemo Analyze 5.13 is compatible with Nemo log files up to file format v. 2.01 (Nemo Outdoor 5.1, Nemo Handy 2.7), and all older file format versions Nemo Analyze 5.13 supports files from following TEMS tools: - TEMS investigation from version 6.0 to 9.1 - TEMS investigation GSM 5.0 and higher - TEMS investigation WCDMA 3.0 and higher - TEMS Pocket up to version 6.0 - TEMS Automatic up to version 7.0
6 Known Issues
Loading more than ~5 TEMS files into the database at the same time may fail. Queries fail from log files where there is more two or more adjacent <space> characters Running multiple reports simultaneously may cause instability Formatting merged cells in the spreadsheet does not work Formatting cells in spreadsheet resets old formatting, if multiple cells with different previous formatting are being handled. Ribbon bar commands cascade, tile horizontally, and tile vertically do not work in Windows Vista OS Nemo Analyze 5.13 affects Nemo Outdoor 4.24 functionality, when installed to the same PC. Voice call testing, and decoding of the signalling messages does not work in Nemo Outdoor. Connection to 3rd party ODBC data sources is limited by memory consumption. Connection to 3rd party ODBC data sources may fail if the 3rd party ODBC connection memory consumption is high.
18
Kiviharjunlenkki 1D | FI-90220 Oulu | Finland | tel. +358 50 395 7700 | fax +358 8 551 6183 | www.anite.com/nemo