Calculul panelor conform Eurocod 3 - 2005 si Eurocod 8 - 2004 1) Caracteristici geometrice IPE220:
h w := 201.6mm t w := 5.9mm b := 110mm t f := 9.2mm h := h w + t f = 210.8 mm fy := 235 N mm E := 210000
2
N mm
2
G := 81000
N mm
2
235 := fy
N mm
2
A := h w t w + 2 b t f = 3.213 10 mm Av := h w t w = 1.189 10 mm Iy := i y := h w tw 12 Iy A
3 3 2
2 b tf 12
= 90.858 mm
Iy 5 3 Wy := = 2.412 10 mm 0.5 h w + t f
Wpy := b t f h w t w 12 Iz A
3
Iz := i z :=
= 2.044 10 mm
= 25.223 mm
h w t w 4
= 5.741 10 mm
Modulul plastic de rezistenta dupa z-z Momentul de inertie la torsiune simpla Moment de inertie sectorial
1 3 3 4 4 It := h w t w + 2 b t f = 7.091 10 mm 3 h 10 6 Iw := Iz = 2.271 10 mm 4
2
Eforturile de calcul:
Ned := 1kN Ved := 60kN M ed := 50kN m
:= hw tw
z + 0.5 h w
= 0.501 456 13 1
= 82.749
<
3) Verificare de rezistenta:
Ned = 1 kN Vrd := Av Ved Vrd fy M0 3 Ved = 60 kN = 1.614 10 N Ved Vrd Ved Vrd
5
M ed = 50 kN m
= 0.372
<1
< 0.5
rezulta ca efectul fortei taietoare poate fi neglijat fy 5 Nrd := A = 7.552 10 N M0 M rd := Wy Ned Nrd + M ed M rd fy M0 = 5.667 10 N m
4
= 1.324 10
= 0.882 M ed M rd
= 0.884
<1