ANALIZA OPTEREENJA

SNIJEG
Snijeg se rauna po pojednostavljenoj formuli i to:
s=(75+(A-500)/4)0,01
kako se objekat nalazi u Sarajevu, dakle A=630 m tada je:
s=(75+(630-500)/4)0,01= 1,075 kN/m2

STALNO
-vl. teina_____________________________________uzeta u programskom paketu
-instalacije____________________________________0,1 kN/m2
-krovni pokriva________________________________0,135 kN/m2
g= 0,235 kN/m2
POKRETNO
-snijeg_______________________________________1,075 kN/m2
-vjetar_______________________________________0,712 kN/m2
p= 1,787 kN/m2

SADRAJ:

-PROJEKTNI ZADATAK_______________________________________________________3
-TEHNIKI OPIS____________________________________________________________4
-ANALIZA OPTEREENJA_____________________________________________________5
-STATIKI UTICAJI__________________________________________________________12
-PRORAUN I KONTROLA NAPONA____________________________________________15