MC LC
QUN L V BO V MI TRNG TRONG GIAI ON CHUN B U T XY DNG QUN L V BO V MI TRNG TRONG GIAI ON TRIN KHAI THI CNG XY DNG QUN L V BO V MI TRNG TRONG GIAI ON HOT NG CC QUY NH V QUAN TRC MI TRNG CC QUY NH V X L VI PHM PHP LUT TRONG LNH VC BO V MI TRNG Ph lc 1 46 6 13 20 30 36
TABLE OF CONTENT
ENVIRONMENTAL MANAGEMENT AND PROTECTION DURING THE CONSTRUCTION PREPARATION PERIOD ENVIRONMENTAL MANAGEMENT AND ENVIRONMENTAL PROTECTION DURING THE CONSTRUCTION IMPLEMENTATION PERIOD ENVIRONMENTAL MANAGEMENT AND PROTECTION DURING THE OPERATIONAL PERIOD ENVIRONMENTAL MONITORING REGULATIONS REGULATIONS ABOUT LEGAL VIOLATIONS ENVIROMENTAL PROTECTION AREA Annex 1 47 IN THE 7 14
21 31 37
48
49
CC CH VIT TT
BVMT: Bo v mi trng CKBVMT: Cam kt bo v mi trng CTNH: Cht thi nguy hi CTR: Cht thi rn DA: D n Q: lu thng nc thi Q: Quyt nh QPD: Quyt nh ph duyt SX, KD, DV: Sn xut, kinh doanh, dch v
ACCRONYM
CEP: Commitments for Environmental Protection DONRE: Department of Natural Resources and Environment EIA: Environmental Impact Assessment EPP: Environmental Protection Plan EPA: Environmental Protection Agency MONRE: Ministry of Natural Resources and Environment
TM: Bo co nh gi tc ng mi trng TNMT: Ti nguyn v Mi trng N: Ngh nh NTSH: Nc thi sinh hot NTSX: Nc thi sn xut 2 TT: Thng t UBND: y ban nhn dn VSIP: Vit Nam - Singapore
m 2011 Chi cc Bo v mi trng tin hnh bin son v in n Cm nang bo v mi trng dnh cho ch Doanh nghip phn phi n cc doanh nghip. Trong nm va qua, cc vn bn php lut v bo v mi trng c nhng thay i v c cc vn bn mi thay th cho cc vn bn trc y. Do , kp thi cung cp cc thng tin v cc quy nh mi ca php lut bo v mi trng n ch cc c s sn xut cng nghip, Chi cc Bo v mi trng t chc bin son li ti liu ny nhm cp nht cc quy nh mi nht v bo v mi trng m doanh nghip cn phi bit, phi thc hin k t khi chun b thnh lp n khi i vo sn xut n nh. y l ti liu hng dn rt hu ch dnh cho cc Doanh nghip thc hin cc gii php bo v mi trng cho c s sn xut ca mnh; ng thi cng l ti liu tuyn truyn b ch dnh cho cc cn b lm cng tc qun l nh nc v mi trng. Trong qu trnh bin son c th s c mt s vn cha hon chnh, Ban bin tp rt mong nhn c nhng kin ng gp qu bu ca cc nh qun l, cc chuyn gia mi trng ti liu c hon thin hn trong nhng ln ti bn sau. Trn trng. BAN BIN TP
LI GII THIU
n 2011, Environmental Protection Agency compiled and printed Environmental protection manual for business owners to distribute to enterprises. In recent years, the legal documents for environmental protection have been changed and new documents replaced old ones. Therefore, in order to update timely information as well as new rules of the environmental protection law to the owners of industrial production facilities, Environmental Protection Agency has recompiled this document to instruct the latest laws about environmental protection issues that the enterprise need know and has to perform from established preparation to production stably. This guide-material not only is very useful for enterprises to implement measures of environmental protection for their production facilities but also is helpful propaganda material for cadres working in State management about environmental field. During compilation process, may have some uncompleted issues so the editorial board looks forward to receiving valuable comments of managers, environmental experts in order that the manual can be improvable in next editions. Sincerely, EDITORIAL BOARD
PREFACE
- Mineral exploration and production projects: before applying for or before asking approval on the modifications of the Mineral Exploration and Production License. - Projects with construction works: before applying for Construction License and before asking for approval on the modifications of the Construction License. - Other projects: before the investment decision is made. 4. Where to submit the EIA/CEP - EIA: to the DONRE or MONRE as regulated in the Annex III List of projects under the MONREs EIA review and approval issued together with the Decree 29/2011/N-CP. - CEP: to the Districts Peoples Committee where the project takes place.
Remarks: If an enterprise or entity (manufacturing, business, services) has the need to modify, expand, upgrade, increase capacity and the new production capacity (including the existing one plus the expanded one) meets the capacity requirements as listed in the Annex II of Decree 29/2011/NCP), the enterprise would need an EIA, otherwise, only CEP is needed for the expansion project.
Lu : Nu c s SX, KD, DV ang hot ng nhng c nhu cu ci to, m rng, nng cp, nng cng sut m c tng cng sut (hin hu v m rng) tng ng vi cc DA c quy nh ti ph lc II ca N 29/2011/N-CP th lp TM, ngc li lp CKBVMT cho DA m rng.
II. LM TH NO LP TM CHO D N?
1. H s ngh thm nh gm: - Mt (01) vn bn ngh thm nh theo mu quy nh ti Ph lc 2.3 ca TT 26/TT-BTNMT - By (07) bn TM theo cc ni dung, cu trc quy nh ti Ph lc 2.4 v 2.5 ca TT 26/2011/TT-BTNMT. - Mt (01) bn DA u t (bo co nghin cu kh thi) c ch k v ng du ca ch DA. 2. Thi gian thm nh: 45 ngy lm vic
Lu : Trong qu trnh lp TM, ch DA phi tham vn kin UBND cp x ni thc hin DA v i din cng ng dn c, t chc chu tc ng trc tip ca DA.
III. LM TH NO LP CKBVMT?
1. H s ng k i vi DA u t khng thuc i tng phi lp TM gm: - Ba (03) bn CKBVMT theo mu quy nh ti Ph lc 5.1 v 5.2 ca TT 26/2011/TT-BTNMT. - Mt (01) bn DA u t (bo co nghin cu kh thi) c ch k v ng du ca ch DA. 2. H s ng k i vi cc DA khng thuc i tng phi lp DA u t v khng thuc i tng phi lp TM gm: - Ba (03) bn CKBVMT theo mu quy nh ti Ph lc 5.3 ca TT 26/2011/TT-BTNMT.
- Three (03) CEP using the template as regulated in The Annex 5.3, Circular 26/2011/TT-BTNMT. - One (01) Report describes the details of manufacturing, business, and services signed by authorized representative persons and stamped with the enterprises chop. 3. Approval time: 5 working days
Remarks: During the project implementation, if there is any modifications and changes to the contents of the EIA Report and of the CEP Report, and to the approved environmental protection measures, the project owners must notify and get approval of the authorized agencies who have approved the Report before making any changes.
- Mt (01) bn thuyt minh v phng n SX, KD, DV c chng thc bi ch k ca ngi i din c thm quyn v v ng du ca c s SX, KD, DV. 3. Thi gian xc nhn: 05 ngy lm vic
Lu : Trong qu trnh trin khai DA u t, hot ng sn xut, kinh doanh nu c nhng iu chnh, thay i v cc ni dung ca TM, CKBVMT v bin php BVMT c ph duyt, xc nhn: phi c bo co bng vn bn gi c quan ph duyt, xc nhn v ch c php thc hin sau khi c kin chp thun bng vn bn ca c quan ny.
10
11
Remarks: When there is no change in terms of designed production capacity, technology and the environmental impacts, the project just needs to submit a document detailing the changes to the approving/registration agencies for modification approval.
12
13
ENVIRONMENTAL MANAGEMENT AND ENVIRONMENTAL PROTECTION DURING THE CONSTRUCTION IMPLEMENTATION PERIOD
14
15
I. WHAT SHOULD AN ENTERPRISES OWNER NEED TO DO AFTER THE EIA GETS APPROVED?
1. Adjust the investment project to ensure that it is in line with the requirements specified in the decision for the EIA Approval; 2. Make, get approved and publish the environmental management plan at the Peoples Committee of the commune where the public consultation process has taken place to inform the local people so that they can monitor the implementation. 3. Coordinate the implementation of environmental protection measures during investment preparation phase and during the construction phase in accordance with the requirements specified in the decision for the EIA Approval; The contruction of wastewater treatment systems 4. Design and install environmental facilities including wastewater treatment, hazardous waste and non-hazardous waste management, air and dust emission treatment, etc. as committed in the approved EIA;
Xy dng h thng x l bi
5. Conduct the operational trials of the waste treatment facilities; 6. Create a file to ask for inspection and approval of the environmental protection facilities before they are put into official operation. The file must use the template in the Annex 4.2, and 4.3, Circular 26/2011/TT-BTNMT.
Remarks: - For those who do not need environmental protection facilities for the operational period, the projects owners are not required to make a file asking for the inspection and certification of environmental protection facilities for the operational period. - In case the project has different investment phases or independent works the projects owners need to create a file asking for the inspection and certification of environmental protection facilities for each phase of the project or for each independent work.
16
17
II. WHAT SHOULD A PROJECT OWNER DO AFTER THE REGISTRATION OF THE CEP?
The projects owner needs to implement all environmental protection measures as committed in the CEP to reduce the negative environmental impacts.
III. LP H S XIN XC NHN THC HIN CC CNG TRNH, BIN PHP BVMT PHC V GIAI ON VN HNH NH TH NO?
1. H s ngh xc nhn gm: - Mt (01) vn bn ngh kim tra xc nhn vic thc hin cc cng trnh, bin php BVMT phc v giai on vn hnh ca DA thc hin theo mu quy nh ti Ph lc 4.2 TT 26/2011/TT-BTNMT; - Mt (01) bn sao quyt nh ph duyt km theo bn sao TM c ph duyt; - Nm (05) bo co kt qu thc hin cc cng trnh, bin php BVMT phc v giai on vn hnh ca DA thc hin theo mu quy nh ti Ph lc 4.3 TT 26/2011/TT-BTNMT. - Nm (05) ph lc vi cc ti liu km theo quy nh ti khon 4 iu 25 N 29/2011/N-CP. 2. Thi gian gii quyt: 40 ngy lm vic.
Cc cng trnh x l cht thi
III. HOW TO MAKE A FILE TO ASK FOR THE CERTIFICATION OF ENVIRONMENTAL PROTECTION FACILITIES?
1. The file must include: - One (01) document asking for the inspection and certification of environmental protection facilities to be used for the projects operational period using the template as regulated in the Annex 4.2, Circular 26/2011/ TT-BTNMT; - One (01) copy of the Decision of the EIA Approval and one (01) copy of the approved EIA; - Five (05) Reports on the implementation results of the environmental protection facilities for the operational period using the template in the Annex 4.3, Circular 26/2011/ TT-BTNMT; - Five (05) Annexes with all related supporting documents as regulated in the Item 4, Article 25 of the Decree 29/2011/N-CP. 2. Processing time: 40 working days.
Remarks: If environmental protection facilities and measures have changed compared with what had been approved in the EIA, these changes need to be described in details (plan, scale, technology, etc.) in the Report on the implementation of environmental protection facilities for the operational period for consideration and approval.
The wastewater treatment
Lu : Nu cc cng trnh, bin php bo v mi trng c thay i, iu chnh so vi phng n c ph duyt trong TM th cn m t r cc thay i, iu chnh (phng n, quy m, cng ngh ) vo Bo co kt qu thc hin cc cng trnh bin php BVMT phc v giai on vn hnh c xem xt, thng nht.
18
19
During the operation period, the enterprise is required to do the following things: 1. Make a file to register the enterprise as a hazardous waste generator; 2. Declare and pay the environmental protection fee for wastewater; 3. Make periodic environmental monitoring reports; 4. Comply with all environmental protection regulations/standards regarding wastewater and air emission; 5. Comply with all environmental protection regulations/standards for solid waste; 6. Comply with all environmental protection regulations/standards for noise, vibration, light, and radiation. 7. Guide the generation of the EPP and the modifications of EIA and of the CEP.
2. K khai v np ph BVMT i vi nc thi. 3. Lp bo co gim st mi trng nh k. thi, kh thi. 4. Tun th cc quy nh BVMT i vi nc
7. Hng dn v lp n BVMT v cc iu
21
- Thc hin ng quy trnh k khai v s dng chng t CTNH mi ln chuyn giao CTNH theo quy nh. - Lp bo co qun l CTNH theo mu quy nh ti Ph lc 4A ca TT 12/2011/ TT-BTNMT vi k bo co 06 thng/ln; - Khi chm dt hot ng, phi thng bo bng vn bn v np li S ng k ch ngun thi CTNH cho Chi cc BVMT.
Lu : Vic lp h s ng k ch ngun thi CTNH khng bt buc i vi mt trong cc - Thi gian hot ng ca DA di 01 (mt) nm; - Pht sinh thng xuyn vi tng s lng khng qu 120 kg/nm i vi cc CTNH c cha cc thnh phn nguy hi c bit vt ngng CTNH theo quy nh ti QCVN 07:2009/BTNMT hoc 600kg/nm i vi CTNH c cha cc thnh phn nguy hi khc.
- Follow the hazardous waste declaration procedure and use the hazardous waste manifest for each hazardous waste transfer as regulated. - Make a Report on hazardous waste management using the template in the Annex 4A, Circular 12/2011/TT-BTNMT every 6 months; - When the operation ends, the enterprise must notify and return the Hazardous Waste Generator Registration Booklet to the EPA.
Remarks: Registration as Hazardous Waste Generator is not applied to the following cases: - The enterprises operational period is less than a year. - Regular generation of no more than 120 kg/year of hazardous wastes containing special hazardous substances exceeding the threadhold as regulated in QCVN 07:2009/BTNMT or no more than 600kg/year for hazardous waste containing other hazardous substances.
trng hp sau:
22
23
24
25
IV. HOW TO FULLY COMPLY WITH ALL ENVIRONNETAL PROTECTION REGULATIONS FOR WASTEWATER & AIR EMISSION?
- Collect and treat all wastewater (including process wastewater and domestic wastewater) and air emission generated during operational period to ensure that treated wastewater and air emission meet the discharge standards; - All wastewater and air emission treatment works must be continuously operated.
Vn hnh h thng x l bi
Lu : Nu c bt k s thay i no v phng n x l so vi phng n c ph duyt/ng k trong TM/CKBVMT, phi c vn bn bo co v c quan qun l mi trng c kin v vic thay i ny v ch c thc hin khi c kin chp thun bng vn bn. Remarks: If there is any change in the environmental treatment measures versus the approved treatment ones in the EIA/CEP, the tentative changes must be communicated to the DONRE in writing for considerations and approval before any change can be made.
VI. HOW TO COMPLY WITH ENVIRONMNETAL PROTECTION REGULATIONS FOR NOISE, VIBRATION, LIGHT AND RADIATION?
The enterprise must ensure that noise level, vibration, light and radiation in the workshop(s) meet industrial hygiene standards as regulated in the document associated with Decision 3733/2002/Q-BYT.
26
27
VII. HOW TO MAKE THE EPP AND HOW TO ADJUST THE CONTENTS OF THE EIA, AND OF THE CEP?
1. If an enterprise (manufacturing, business, and service) is in operation or has completed the construction, equipment installation and trial operation but has not obtained the EIA Approval Decision, Certification of Environmental Standards Compliance, CEP Approval, the enterprise must make the EPP. Files and Procedure for EPP generation and certification are detailed in the Circular 01/2012/TT-BTNMT.
Remarks: - Make the detailed EPP if the scale and the nature of the enterprise are equivalent with those of the enterprises which require the EIA. -Make the simple EPP if the scale and the nature of the enterprise are equivalent with those of the enterprises which require the CEP.
2. Trong qu trnh hot ng, nu c s SX, KD, DV c d n m rng, nng cp, tng quy m, cng sut hoc d kin thay i ni dung TM, CKBVMT phi thc hin nh sau: - Nu d n m rng, nng cp c quy m, cng sut v tng lng cht thi tng di 02 ln hoc c cc ni dung iu chnh, thay i m khng lm pht sinh cht thi mi so vi trc y: phi c vn bn bo co, gii trnh gi v S Ti nguyn v Mi trng hoc c quan xc nhn, ng k CKBVMT c xem xt, thng nht trc khi thc hin vic iu chnh, thay i. - Nu d n m rng, nng cp c quy m, cng sut v tng lng cht thi tng t 02 ln tr ln hoc pht sinh cc loi cht thi mi so vi trc y th phi lp TM hoc CKBVMT v gi v c quan c thm quyn xem xt ph duyt, ng k trc khi trin khai thc hin vic m rng, nng cng sut. 3. Trong qu trnh hot ng, nu c s SX, KD, DV thc hin vic thay i, iu chnh cc ni dung ca TM hoc CKBVMT nhng khng bo co v cha c s thng nht ca c quan c thm quyn l vi phm cc quy nh ca Lut BVMT. Do , cc c s sn xut, kinh doanh phi ch ng khc phc nh sau: - Nu m rng, nng cp, tng quy m, cng sut di 02 ln hoc c tng lng cht thi tng t hn 02 ln phi c vn bn gii trnh v nhng thay i, iu chnh so vi trc y v gi v S Ti nguyn v Mi trng hoc c quan xc nhn, ng k CKBVMT . - Nu m rng, nng cp, tng quy m, cng sut hoc tng tng lng cht thi t 02 ln tr ln hoc pht sinh cc loi cht thi mi, cht thi c thnh phn gy nhim cao hn so vi trc y phi lp n BVMT .
Lu : Cn c vo quy m, cng sut sn xut (bao gm tng cng sut ca phn hin hu v m rng) v i chiu vi quy nh ti Ph lc II N 29/2011/N-CP xc nh lp TM hay CKBVMT cho d n m rng.
2. During the operational period, if an enterprise (manufacturing, business, service) wants to expand, upgrade, up-scale, increase production capacity or plans to adjust the contents of the EIA, CEP, the enterprise needs to do the following things. - If the project is expanded and upgraded to less than twice the current production capacity and generates less than twice the amount of waste, or if the project has some modifications which do not generate any new waste, the project must notify the DONRE or the agency who has approved the CEP for considerations before any change can be made. - If the project is expanded and upgraded to equal or more than twice the current production capacity and thus generates equal or more than twice the amount of waste, or generates new waste, an EIA or CEP must be made and submitted to the authorized organizations for considerations, approval and registration before the expansion and production scale-up can be implemented. 3. During the operational period, if an enterprise has implemented the changes versus the contents of the EIA or of the CEP without notifying and getting approval from authorized agencies, the enterprise has violated the Vietnam environmental protection law. Therefore, the enterprise must actively make remediation as follows. - If the entity has expanded the production to less than 2 times or the increased waste generation is less than 2 times, a document detailing the changes and modifications compared with the previous setting must be sent to DONRE or to the organization who had approved the CEP. - If the entity has expanded the scale and production capacity more than twice and generated the waste more than twice or generates new waste or waste with higher polluting substances compared with the previous setting, the enterprise must make the EPP.
Remarks: Compare the projects scale and production capacity (including the current production capacity and the expanded one) with those in the Annex II Decree 29/2011/N-CP to decide if an EIA or CEP needs to be produced for the projects expansion.
28
29
30
31
m3/ngy.m v tt c cc khu cng nghip, cm cng nghip v phi lp t thit b o lu lng t ng, mang o thuy lc v thit b quan trc cht lng nc thi t ng. - Chu ngun thai c Q t 200 - 1.000
Thit b o lu lng t ng
- All wastewater generators with the wastewater discharge flow of more than 1,000m3/24hrs, all industrial parks and industrial clusters need to install the automatic flow meter, hydraulic weir and automatic wastewater quality monitoring equipment. - Wastewater generators of between 200m3 and 1,000m3/24hrs must have both flow measurement meter and hydraulic weir. - Wastewater generators of less than 200m3/24hrs need to install hydraulic weir.
m3/ngy.m phi lp t ng thi ng h o lu lng va mang o thuy lc; - Chu ngun thai c lu lng nc thi Q < 200 m3/ngy.m phi lp t mng o thu lc.
Hydraulie Weir
Mng o thy lc
Lu : Thit bi quan trc nc thai t ng phai c xy dng va lp t ung theo Quy nh hng dn k thut i vi thit b quan trc t ng do S TNMT ban hnh. Thit bi quan trc lu lng, cht lng nc thai t ng phai c kt ni vao Trm iu hnh H thng quan trc nc thi t ng cua S TNMT.
Remarks: The automatic wastewater quality monitoring equipment must be built and installed in accordance with the Technical Guidance on the automatic wastewater quality monitoring equipment issued by the DONRE. The flow monitoring device, and the automatic wastewater sampler and analyzer (or the automatic wastewater quality monitoring equipment) must be connected with the Control Room of the DONREs automatic wastewater monitoring network.
32
33
II. HOW TO IDENTIFY SAMPLING LOCATIONS FOR THE SOURCE OF WASTEWATER DISCHARGE?
1. Construction of the wastewater source sampling points - When building the wastewater discharge points into the common wastewater network, the manhole should be positioned at the place convenient for wastewater inspection and supervision. The manhole should be placed next to the entitys fence at the outside to facilitate the supervision of the wastewater discharge by the local authorities and management agencies. - The cover of the manhole should be designed and constructed to facilitate the wastewater monitoring and to be easily opened when needed. To facilitate wastewater monitoring and sampling, the manholes minimum diameter or width should be 0.7m; the wastewater inlet must be placed 0.5m above the bottom of the manhole, and wastewater outlet must be placed 0.3m above the manholes bottom - Strictly ban the construction of the hidden wastewater discharge points. 2. Construction of the air emission monitoring points - The generator of air emission or exhaust air via stacks needs to build the air emission or exhaust air monitoring points on the air emission discharge pipeline or on the stack. - The exhaust air monitoring point must be placed at the height level which is at least 3 times of the stacks diameter. The exhaust air sampling points diameter is 100mm for stacks with diameter of more than 300mm; and is 10mm for stacks with diameter of less than 300mm. Each stack must have 2 exhaust air sampling points on the same cross sectional area and together with the center point of the crosssectional area to make an angle of 900.
35
36
37
1. Pht tin t 2.000.000-5.000.000, nu: - Khng nim yt cng khai ti a im thc hin DA bn tm tt TM. - Khng bo co hoc bo co sai s tht v k hoch xy lp cc cng trnh x l mi trng. - Khng xy dng v gi k hoch vn hnh th nghim cc cng trnh x l mi trng. - Khng bo co hoc bo co sai s tht v nhng iu chnh, thay i cc ni dung, bin php BVMT trong TM. 2. Pht tin t 40.000.000-70.000.000 ng nu khng thc hin ng, khng y cc ni dung trong TM v QPD. 3. Pht tin t 70.000.000 100.000.000 ng, nu: a cng trnh vo s dng khi cha c c quan c thm quyn kim tra, xc nhn vic thc hin ng, y ni dung trong TM. 4. Pht tin t 130.000.000-170.000.000 ng nu khng xy lp, xy lp khng ng, khng vn hnh, khng vn hnh thng xuyn hoc vn hnh khng ng quy trnh x l mi trng c duyt. 5. B pht tin t 200.000.000 - 300.000.000 ng nu khng c TM hoc n BVMT.
1. Pay a fine from VND 2,000,000 to VND 5,000,000 if: - Not published the brief of the EIA at the projects location; - No report or make a false report on the construction plan of the environmental protection facilities; - Not build and not submit the operational trial plan of the environmental treatment facilities; - Not report or make a false report on the modifications of and changes of the contents and the environmental protection measures in the EIA. 2. Pay a fine between VND 40,000,000 to VND 70,000,000 if the entity does not fully comply with all commitments specified in the EIA and in the EIA Approval Decision. 3. Pay a fine from VND70,000,000 to VND 100,000,000 if put the environmental facilities into operation before getting approval from authorized agencies that the environmental facilities are done properly as committed in the EIA; 4. Pay a fine between VND 130,000,000 and VND170,000,000 if environmental facilities are not built or not built properly; not operated, not regularly operated or not operated in accordance with the approved environmental treatment procedure; 5. Pay a fine from VND 200,000,000 to VND 300,000,000 if the EIA or the EPP is not available.
Kim tra h thng x l nc thi Examine the environmental protection in the company Check the wastewater treatment system
38
39
1. Pht tin t 15.000.000 - 25.000.000 ng nu khng lp bn CKBVMT. 2. Pht tin t 500.000 - 5.000.000 ng nu thc hin khng ng hoc khng y cc ni dung ca bn CKBVMT. 3. Pht tin t 10.000.000 - 15.000.000 ng nu khng xy dng, xy dng khng ng, khng vn hnh, khng vn hnh thng xuyn hoc vn hnh khng ng quy trnh x l mi trng cam kt.
1. Pay a fine from VND 15,000,000 to VND 25,000,000 if the CEP Report is not available. 2. Pay a fine from VND 500,000 to VND 5,000,000 if the entity does not properly implement or not fully implement the contents of the CEP Report. 3. Pay a fine from VND 10,000,000 to VND 15,000,000 if the environmental facilities are not built, not properly built, not regularly operated, or not operated in accordance with the environmental treatment measures as committed.
III. VIOLATIONS OF REGULATIONS ON WASTEWATER DISCHARGE, AIR EMISSION AND DUST EMISSION?
1. For wastewater Those who violate the wastewater regulations will be fined according to the Article 10 and Article 14 Decree 117/2009/ N-CP and depending on the wastewater discharge flow and the wastewater concentration, the fine varies from VND 100,000 to VND 500,000. The details are as follows. - The exceeding level is lower than 2 Discharge of environmental pollutionts times: the fine is from VND 100,000 to VND 150,000,000 - The exceeding level is between 2 times to lower than 5 times, the fine is from VND 500,000 to VND 200,000,000 - The exceeding level is from 5 times to less than 10 times, the fine is from VND 2,000,000 to VND 250,000,000 - The exceeding level is equal to or more than 10 times, the fine is from VND 8,000,000 to VND 300,000,000 - The fine from VND 400,000,000 to VND 500,000,000 for discharged wastewater containing over-standard radiation substances. Environmental protection manual for business owners 41
lu lng v nng vt tiu chun, quy chun m mc pht t 100.000 500.000.000 ng, c th nh sau: - Vt di 2 ln, mc pht t 100.000 -
150.000.000 ng.
- 200.000.000 ng.
- Vt t 2 di 5 ln, mc pht t 500.000 X nc thi gy nhim ra mi trng - Vt t 5 di 10 ln, mc pht t 2.000.000 - 250.000.000 ng. - Vt t 10 ln tr ln, mc pht t 8.000.000 - 300.000.000 ng. - Pht t 400.000.000 - 500.000.000 ng i vi hnh vi x nc thi c cha cht
phng x gy nhim x mi trng vt tiu chun, quy chun k thut cho php. 40 Cm nang bo v mi trng dnh cho nh qun l doanh nghip
trng, mc pht t 500.000 - 2.000.000 ng. - Vt di 1,5 ln, mc pht t 1.000.000 - 120.000.000 ng
- Vt t 1,5 di 2 ln, mc pht t 2.000.000 - 150.000.000 ng. - Vt t 2 di 3 ln, mc pht t 5.000.000 - 200.000.000 ng. - Vt t 5 ln tr ln, mc pht t 20.000.000 - 300.000.000 ng. - Vt t 3 di 5 ln, mc pht t 20.000.000 - 250.000.000 ng. - Pht t 400.000.000 - 500.000.000 ng i vi hnh vi x kh thi c cha cht
phng x gy nhim x mi trng vt tiu chun, quy chun k thut cho php.
2. For air emission: Those who violate the air emission regulations will be settled by the Article 11 and the Article 14 Decree 117/2009/ N-CP and depending on the air emission flow and the extent of the air emission concentration violation, the fine is from VND 100,000 to VND 500,000,000. The details are as follows. - Discharge the odor and nuisance smell Exhaust emissions polluting the environment into the environment: the fine is from VND 500,000 to VND 2,000,000; - The exceeding level is less than 1.5 times: the fine is from VND 1,000,000 to VND 120,000,000; - The exceeding level is from 1.5 times to less than 2 times, the fine is from VND 2,000,000 to VND 150,000,000; - The exceeding level is from 2 times to less than 3 times: the fine is from VND 5,000,000 to VND 200,000,000; - The exceeding level is from 3 times to less than 5 times: the fine is from VND 20,000,000 to VND 250,000,000; - The exceeding level is equal to or more than 5 times: the fine is from VND 20,000,000 to VND 300,000,000; - Those who emit the air emission containing over-standard radiation substances: the fine is from VND 400,000,000 to VND 500,000,000.
vibration
fined
42
43
The environmental police discovered hazarduos waste landfill in contravention of regulations Lu gi CTNH khng ng theo quy nh
44
45
PH LC 1
ANNEX 1
RELATED REGULATIONS
1. Environmental protection Law, November 29, 2005 2. Decree 67//2003/N-CP dated June 13, 2003 on environmental protection fee for wastewater; 3. Decree 59//2007/N-CP dated april 9, 2007 by the Prime minister on solid waste management; 4. Decree 04/2007/N-CP dated January 8, 2007 by the Government on the modifications and the admendments of some articles of the Deree 67/2003/N-CP dated June 13, 2003 by the Government on environmental protection fee for wastewater; 5. Decree 117/2009/N-CP dated December 31, 2009 on environmental protection violation fines; 6. Decree 29/2011/N-CP dated on April 18, 2011 by the Government on strategic EIA, EIA and environmental protection commitments; 7. Circular 26/2011/TT-BTNMT dated July 18, 2011 by MONRE specifies some articles of the Decree 29/2011/N-CP dated on April 18, 2011 of the Government on strategic EIA, EIA, and environmental protection commitments; 8. Circular 01/2012/TT-BTNMT dated March 16, 2012 by MONRE on the production, review, approval and checking of the detailed implementation of the EPP. 9. Circular 08/2009/TT-BTNMT dated July 17, 2009 by MONRE about environmental management and protection of economic zones, high-tech industrial parks, industrial parks and industrial complexes, and Circular 48/2011/TTBTNMT dated December 28, 2011 by MONRE on the modifications and amendments of the Circular 08/2009/TT-BTNMT; 10. Circular 12/2011/TT-BTNMT dated April 14, 2011 by MONRE on hazardous waste managment; 11. Circular 16/2009/TT-BTNMT dated October 7, 2009 by MONRE on the issuance of the national technical regulation on environment protection; 12. Circular 25/2009/TT-BTNMT dated November 16, 2009 by MONRE on the issuance of the 8 national technical regulations on Environmental Protection; 13. Circular 39/2010/TT-BTNMT dated December 16, 2010 by MONRE the isuance on National Technical Regulations on Environmental Protection; 14. Circular 47/2011/TT-BTNMT dated December 28, 2011 by MONRE on the issuance of the National Technical Environment Regulation QCVN 40: 2011/BTNMT National Technical Regulation on industrial wastewater; 15. Circular 42/2010/TT-BTNMT dated December 29, 2010 by MONRE the isuance on National Technical Regulations on Environmental Protection; 16. Circular 41:2010/TT-BTNMT dated December 28, 2010 by MONRE the isuance on National Technical Regulations on Environmental Protection; 17. Circular 43/2010/TT-BTNMT dated December 29, 2010 by MONRE the isuance on National Technical Regulations on Environmental Protection; 18. Circular 43/2007/Q-BYT dated December 16, 2010 by MONRE the isuance on National Technical Regulations on Environmental Protection; 19. Decision 04/2008/Q-BTNMT dated July 18, 2008 regarding the issuance of National Technical Regulations on Environment; 20. Industrial Hygiene Standards issued by Ministry of Health in association with the Decision 3733/2002/Q-BYT dated October 10, 2002 by Ministry of Health; 21. Environmental Protection Regulations of Binh Duong Province.
46
47
BAN BIN TP
Ch o bin son: S Ti nguyn v Mi trng tnh Bnh Dng Chu trch nhim bin son ni dung: Chi cc BVMT a ch lin h: Chi cc BVMT - S Ti nguyn v Mi trng 186 i l Bnh Dng, th x Th Du Mt, tnh Bnh Dng in thoi: 0650.383 4766; Fax: 0650.3838556 bit thm thng tin v: + Qun l v BVMT trong giai on chun b u t xy dng v trong giai on trin khai thi cng xy dng, vui lng lin h: Phng Thm nh v nh gi tc ng mi trng in thoi: 0650.3834765 + Qun l v BVMT trong giai on hot ng, vui lng lin h: Phng Kim sot nhim in thoi: 0650.3823398 48 Cm nang bo v mi trng dnh cho nh qun l doanh nghip
EDITING BOARD
Compiled under the direction of: Binh Duong DONRE Responsible for the content: EPA Contacts: EPA - Binh Duong DONRE Add: 186 Binh Duong avenue, Thu Dau Mot city, Binh Duong province Phone: 0650: 3834765; Fax: 0650.3838556 For more information about: + Environmental management and protection and environmental management and environmental protection during the construction implementation period, please contact: EIA Review Division Phone: 0650: 3834765 + Environmental management and protection during the operational period, please contact: Pollution Control Division Phone: 0650: 3823398 Environmental protection manual for business owners 49
50
51
In 5.000 cun 18x25 ti Cng ty CP In An Nhn - annhanprinting.net Giy php xut bn s 36/GPXB-STTTT ngy 28/11/2012 ca S Thng tin v Truyn thng tnh Bnh Dng. In xong v np lu chiu thng 12/2012
52