Professional Documents
Culture Documents
EC5 Timber Design - Fire Calculation
EC5 Timber Design - Fire Calculation
1) Cross section
Shape
Dimensions(cm)
Cross sections(cm)
Inertia(cm4)
Modules(cm3)
Dimension factor
Modification factor
(table 3.1)
Deformation factor
(table 3.2)
Material(MPa)
Grade(MPa)
R7.5*20
h = 20.00 b = 7.50
Area = 150.00 Sy = 125.00 Sz = 125.00
It = 2149.14 Iy = 5000 Iz = 703.125
Welyinf = 500 Welysup = 500
Welzinf = 187.5 Welzsup = 187.5
kh(N) = 1.149 kh(My) = 1.000 kh(Mz) = 1.149
kmod = 0.900
kdef = 0.600
E = 11000 = 0.0
Fmk = 24 Ft0k = 14 Fc0k = 21 Fvk = 2.5
2) Deflections
Case no 102, Mesh No. 1.2
WinstQ: L/4704 < L/500 (11 %)
Winst: L/2744
Wcreep: L/8575
Wfin: L/2079 < L/300 (14 %)
Wnetfin: L/2079 < L/300 (14 %)
3) Cross sections strength
Tension
Compression
Shear
Oblique bending
Torsion
4) Elements stability
Verification
Report No.:
c0d
176255111
Page 1
Project:
5) Fire resistance
Tension
Compression
Shear
Oblique bending
Torsion
Burned Section
Values
Report No.:
176255111
Page 2