Earth Leakage Relays TZS Series

Ratings of Relays
Type Phase and wires Outside view 33W, 12W 34W TZS-AD NOTE ' : Standard, this configuration is used unless otherwise specified. : yes or available. q : Terminals for 120V AC and 240V AC are provided. CAUTION : DO NOT APPLY 240V AC TO THE 12OV AC TERMINAL., BURNOUT CAN RESULT. w : For 415V AC or 440V AC, Please contact to TERASAKI. e : Adjustable type by Dip slide swnch. r : Operating time range and Non-operating time range.
Rated operating time (sec) Operating time range (sec) 0.2~0.36 0.4~0.6 0.8~1.2 1.3~2 Non-operating time range (sec) 0.15 0.38 0.7 1.25

RATINGS Rated control voltage [V AC] 50/60Hz Applicable range Rated sensitivity current [mA] 120V AC 240V AC

0.3

Rated operating time (sec)

Dimensions [mm] (surface mount) W/H/D Weight [kg] (surface mount) MOUNTING Surface mount Flush mount STANDARD FEATURES Earth leakage detection Output contact Earth leakage indication Reset function Power source required

120 qw 240 96-132 192-264 30 100 300 e 500 1000 below 0.04 0.3 0.5 er 1 2 60/78/100 0.22 ' t 1C y LED (Red) electrical u 1VA

0.5 1 2

t : Solied-state type, current operating type. y : Ratings of output contact.


Resistance load cos = 1 120V AC 240V AC 30V DC 6A 6A 6A Inductive load cos = 0.4 (L/R=7ms) 3.5A 3.5A 3A 10mA at 5V DC Min. load

u : The output contacts remain until the RESET button is operated. Provided the control power supply fails the contacts automatically reset.

Ratings of ZCT (Core Balanced Current Transformers)


Type Outside view TZS-15 TZS-24 TZS-40 TZS-68 TZS-100

Diameter of transit part [mm] Weighr [kg] Applicable numbers, size and continuous current of wires (IV cable wires) 2 max. continuous current wires max. wire size max.diameter of wire 3 max. continuous current wires max. wire size max.diameter of wire 4 max. continuous current wires max. wire size max.diameter of wire

15 0.2

24 0.3

40 0.7

68 1.1

100 2.0

61A 8mm2 6mm 61A 8mm2 6mm 49A 5.5mm2 5mm

139A 30mm2 10.5mm 139A 30mm2 10.5mm 115A 22mm2 9.5mm

298A 100mm2 17mm 298A 100mm2 17mm 257A 80mm2 15.5mm

650A 325mm2 29mm 650A 325mm2 29mm 556A 250mm2 26mm

1185A 850mm2 45mm 1185A 850mm2 45mm 992A 600mm2 38mm

Outline dimensions

Connection Diagram

Earth Leakage Relay


Surface mount Type
10M3~0.5 43 29

Earth Leakage Relay


Output contacts (1 C ) ZCT connecting terminals

z2

z1

Test button LED, red (LEAKED) Earth leakage monitor (ZCT)

31

50 40 36

RESET

TEST

78

NORMAL

LEAKED

78

LED, green (NORMAL) Reset button Response current/ time delay selector switch
AC200/240V AC100/120V COM

31

50 60

24.5 Response current/time delay selector switch

4 100

Control power terminals

Drilling plan
2M4~0.7 Tapped hole

TZS-AD ZCT wire length 30mA: less than 3m, 100, 300mA: less than 5m, 500, 1000mA: less than 10m Note: The output contacts are hold until the reset button is pressed. Loss of control power resets the contacts automatically. Terminal screw tightening torque: 0.45 0.73 N.m (4.6 7.4 kgf.cm)

Earth Leakage Trip Characteristic


62
below 0.04 sec
Rated Non-operating current
60 30 20 10

0.3 sec
Rated Non-operating current
60 30 20 10 60

0.5 sec
Rated sensitivity current
10

Rated sensitivity current

Operating time (S)

Operating time (S)

5 2 1 0.5 0.2 0.1 0.05 0.01

5 2 1 0.5 0.2 0.1 0.05 0.01

Operating time (S)

5 2 1 0.5 0.2 0.1 0.05 0.01

50

Flush mount Type


Response current/time delay selector switch 2M4~0.7

Non-operating time range

Drilling plan
Mounting plate (t=3max.) 24.5
Operating time (S)

0.01 25

50

100

500

1000

0.01 25

50

100

500

1000

0.01 25

50

100

Rated sensitivity current Non-operating time range

30 20

Rated Non-operating current

500

1000

Percent ground-fault current

Percent ground-fault current

Percent ground-fault current

1 sec
Rated sensitivity current Rated Non-operating current
60 30 20 10 5 2 1 0.5 0.2 0.1 0.05 60 30 20 10

2 sec
Rated Non-operating current Rated sensitivity current Non-operating time range
50 100

Operating time (S)


1000

5 2 1 0.5 0.2 0.1 0.05 0.01

R 2

RESET

TEST

56 70

42

56

NORMAL

LEAKED

Non-operating time range

70

52 4 t 106.5

0.01 0.01 25 50 100 500

0.01 25

500

1000

Percent ground-fault current

Percent ground-fault current

Earth Leakage Monitor (ZCT)


TYPE !
2M3~0.5 28 2M3~0.5 D 3 C 5 F C L

TYPE @

H C L
Z2 Z1

d B E 44.5 TypeTZS-15 is 44.5~5.5 B

C E

46 58

G H

27 30

ZCT Type TZS-15 TZS-24 TZS-40 TZS-68 TZS-100

TYPE ! ! @ @ @

Relay Type TZS-15AD TZS-24AD TZS-40AD TZS-68AD TZS-100AD

d 15 24 40 68 100

A 30 42 45

B 55 67 71 85 105

C 60 72 113 141 181

D 32 40 51 65 85

E 28 32 62 76 96

F 57 70 90

G 25 34 110 134 150

H 46 58 130 150 170