4 Inspection tours
2. Fire hazards

generic inspection items


23. Machine guards and shrouds properly installed. 24. Vent and drain caps installed. 25. Water intake and ventilation systems are clear of debris. 26. Electrical panels and boxes are closed and secure 27. Power supplies operational and normal. 28. Local alarm systems operable. 29. Local control panels are free of alarms 30. Local recorders operating properly. 31. Status and alarm lights operable. 32. Normal power consumption on local meters 33. Electrical Breakers: a. In alignment. b. Trips in reset condition. c. Enclosures normal temperature and absence of smells. d. Position and alarm lights operating correctly. 34. Charging springs charged and control power present. 35. Equipment grounding devices intact. 36. Cable straps secured. 37. All hoses properly stored. 38. Insulation installed and not damaged. 39. Building integrity. 40. Lighting operational. 41. Floor drains open an operational. 42. Contractors working in compliance with facility O&M standards, EHS rules and PTW.

1. General housekeeping and cleanliness 3. Escape routes free of obstructions 4. Fire barriers intact. 5. Fire doors closed and not locked. 6. Non fire doors and gates closed and locked as required. 7. Ladders and gas bottles properly stored. 8. Scaffolds properly erected and tagged 9. Open trenches roped off and signed. 10. Operating equipment accessible and not hindered. (e.g. by scaffolding.) 11. Equipment labels installed and legible. 12. Safety tags and lock out materials in order. tag out

13. Pipes and values are free of leaks and seeps. 14. Walking surfaces are free of water, oil or other hazards. 15. Sumps: a. liquid levels normal b. pumps operational. c. Free of contamination (oil, organics.) 16. Normal system temperatures, flows, pressures, quality. 17. Investigation of unusual noises, smells, vibrations. 18. Oil and grease level normal 19. System line up. 20. Suction, discharge and minimum flow valves properly aligned. 21. Motor and pump housing temperatures normal. 22. Belts and couplings are tight and free of vibration.

File: ACWA Power OM Standards and Guidelines Rev 1 5b 030610

Page 97 of 131

You might also like