Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH Phase System Wire 3 3 + GND 3 3 + GND Wire Size 1 4 Amps 95 48 Breaker 150 80
Drain Requirements
Connection Size inches mm 8 203 Discharge Rate gal/min liters/min 380 1435 Min Sewer Line inches mm 8 203
Water Requirements
Connection Size US Metric 2" DN50 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 45 170 Minimum Supply Line Size US Metric 2" DN50 Max Operating Pressure US Metric 125 PSI 8 Bar
Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1-1/4" DN32 30-75 2-5 Minimum Supply Line Size US Metric 1-1/4" DN32 Max Operating Pressure US Metric 100 PSI 6 Bar
REV BY DATE REV. DESCRIPTION
A2
DRAWN BY
AFA
10-4-2013
DATE DATE
Compressed Air
Connection Size US Metric 3/8" NPT Consumption US Metric 1 CFM 0.02 CMM Pressure US Metric 80-100 PSI 5.5-5.7 BAR
A. Adcock 8-18-2005
CHECKED BY DESCRIPTION
C. Oswald 8-18-2005
2540 100 2
2270 89.37
758 29.84
1358 53.46
2472 97.32
570 22.44
REV
BY
DATE
REV. DESCRIPTION
A1
DRAWN BY
AFA
8-18-2005
DATE DATE
Created Drawing
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226
A. Adcock 8-18-2005
CHECKED BY DESCRIPTION
C. Oswald 8-18-2005
8-18-2005
OF
2615 102.95 460 18. 11 847.500 33.37 847.500 33.37 460 18. 11
460 18.11
REV
DATE
REV. DESCRIPTION
FRONT OF MACHINE
A1
DRAWN BY CHECKED BY
AFA
5-2-2008
DATE DATE
Created Drawing
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com
A. Adcock C. Oswald
DESCRIPTION
5-2-2008 5-2-2008
5-2-2008
SA-475 bolt.cdr