Dimensions
Ref A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
REV BY DATE REV. DESCRIPTION

Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH Phase System Wire Wire Size 3 3 + GND 8ga 3 3 + GND 10ga Amps 32 16 Breaker 40 20

Drain Requirements
Connection Size inches mm 4 102 Discharge Rate gal/min liters/min 150 560 Min Sewer Line inches mm 5 127

Water Requirements
Connection Size US Metric 1-1/4" DN 32 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 37 140 Minimum Supply Line Size US Metric 1-1/2 DN 38 Max Operating Pressure US Metric 125 PSI 8 Bar

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 3/4" DN 19 30-75 2-5 Minimum Supply Line Size US Metric 3/4" DN 19 Max Operating Pressure US Metric 100 PSI 6 Bar

Compressed Air
Connection Size US Metric 3/8" NPT Consumption US Metric 0.5CFM 0.01 CMM Pressure US Metric 80-100 PSI 5.5-5.7 BAR

Inch 75.5 71 71.25 63.5 33.25 45.5 61.5 8.5 22.5 4 53 -63.5 69.25 6 11 15.75 21.75 -21 15.75 48.5 72.25 77.75 80.75 72

mm 1918 1803 1810 1613 845 1156 1562 216 572 102 1346 -1613 1759 152 279 400 552 -533 400 1232 1835 1975 2051 1829

A1
DRAWN BY

AFA

12-4-2009
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

Dynamic Load Specifications


Static floor load kN lbs 27.4 6154 Static pressure kN/m2 lbs/ft2 9.3 194 Total Dynamic Load kN lbs 7.703554596 1731.533 Dynamic pressure kN/m2 lbs/ft2 2.6 55 Dynamic Frequency Hz 12.1

A. Adcock 12-4-2009
CHECKED BY

S. Brown
DESCRIPTION

12-4-2009

Shipping Data
Type Domestic Export lbs 5355 5425 kg 2434 2466 cu ft 228.0 228.0 cu m 6.5 6.5