Dimensions

Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH Phase System Wire Wire Size 3 3 + GND 6ga 3 3 + GND 8ga Amps 58 29 Breaker 60 30

Drain Requirements
Connection Size inches mm 4 102 Discharge Rate gal/min liters/min 150 560 Min Sewer Line inches mm 5 127

Water Requirements
Connection Size US Metric 1-1/4" DN 32 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 37 140 Minimum Supply Line Size US Metric 1-1/2 DN 38 Max Operating Pressure US Metric 125 PSI 8 Bar

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1" DN 25 30-75 2-5 Minimum Supply Line Size US Metric 1" DN 19 Max Operating Pressure US Metric 100 PSI 6 Bar

Compressed Air
Connection Size US Metric 3/8" NPT Consumption US Metric 0.5CFM 0.01 CMM Pressure US Metric 80-100 PSI 5.5-5.7 BAR
REV BY DATE

Ref A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
REV. DESCRIPTION

Inch 78 67 85 65 34.25 46.25 64.5 8.5 22 4 56.25 64.25 66.75 72.75 6.5 11.25 16.5 21.25 24.5 20.25 17.25 50.75 76.5 81 84 71

mm 1981 1702 2159 1651 870 1175 1638 216 559 102 1429 1632 1695 1848 165 286 419 540 622 514 438 1289 1943 2057 2134 1803

A1
DRAWN BY

AFA

12-4-2009
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

Dynamic Load Specifications


Static floor load kN lbs 8875 39.5 Static pressure kN/m2 lbs/ft2 229 11.0 Total Dynamic Load kN lbs 11.38143009 2558.211 Dynamic pressure kN/m2 lbs/ft2 66 3.2 Dynamic Frequency Hz 11.7

A. Adcock 12-4-2009
CHECKED BY

S. Brown
DESCRIPTION

12-4-2009

Shipping Data
Type Domestic Export lbs 7675 7765 kg 3489 3530 cu ft 318.9 318.9 cu m 9 9