Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH Phase System Wire Wire Size 3 3 + GND 6ga 3 3 + GND 8ga Amps 89 45 Breaker 90 50

Dimensions
Ref A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
REV BY DATE REV. DESCRIPTION

Drain Requirements
Connection Size inches mm 4 102 Discharge Rate gal/min liters/min 150 560 Min Sewer Line inches mm 5 127

Water Requirements
Connection Size US Metric 1-1/4" DN 32 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 37 140 Minimum Supply Line Size US Metric 1-1/2 DN 38 Max Operating Pressure US Metric 125 PSI 8 Bar

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1" DN 25 30-75 2-5 Minimum Supply Line Size US Metric 1" DN 19 Max Operating Pressure US Metric 100 PSI 6 Bar

Compressed Air
Connection Size US Metric 3/8" NPT Consumption US Metric 0.5CFM 0.01 CMM Pressure US Metric 80-100 PSI 5.5-5.7 BAR

Inch 85 74.25 93 39.5 36.5 51.75 61.5 8.5 25.75 4 61.5 71.5 73 79.5 5.75 10.75 15.75 21.5 30 19.75 18.75 56.75 82.5 88 91 84

mm 2159 1886 2362 1003 927 1314 1562 216 654 102 1562 1816 1854 -146 -400 546 762 502 476 1441 2096 2235 2311 2134

A1

AFA

12-4-2009
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

Dynamic Load Specifications


Static floor load kN lbs 12218 54.4 Static pressure kN/m2 lbs/ft2 256 12.3 Total Dynamic Load kN lbs 17.15636973 3856.248 Dynamic pressure kN/m2 lbs/ft2 81 3.9 Dynamic Frequency Hz 11

DRAWN BY CHECKED BY

A. Adcock 12-4-2009 S. Brown


DESCRIPTION

12-4-2009

Shipping Data
Type Domestic Export lbs 10435 40560 kg 4743 18436 cu ft 388.6 388.6 cu m 11 11
DATE

General Technical Specifications

SI-300
FILE NAME SHEET

12-4-2009

SI-300GenSpec.cdr

OF