A

39.21 995.9

Electrical Requirements

Connection Size inches mm 2-3/8 60

Discharge Rate gal/min liters/min 42 246

Min Sewer Line inches mm 3 76

31.50

800.1

Drain Requirements

50.30 1277.52

Water Requirements
Connection Size US Metric 3/4" DN 19 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 11 40 Minimum Supply Line Size US Metric 3/4 DN 19 Max Operating Pressure US Metric 125 PSI 8 Bar

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1/2" DN 12 30-75 2-5 Minimum Supply Line Size US Metric 1/2" DN 12 Max Operating Pressure US Metric 100 PSI 6 Bar
REV

MOUNTING BOLT DETAIL


BY DATE REV. DESCRIPTION

Dynamic Load Specifications


Static floor load kN lbs 7.6 1718 Static pressure kN/m2 lbs/ft2 7.2 150 Total Dynamic Load kN lbs 3.1 701 Dynamic pressure kN/m2 lbs/ft2 2.9 61 Dynamic Frequency Hz 16

A1
DRAWN BY CHECKED BY

AFA

9-30-2013
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

A. Adcock 9-30-2013 C. Oswald 9-30-2013

Shipping Data
Type Domestic Export lbs 1353 1395 kg 615 634 cu ft 66.9 66.9 cu m 1.9 1.9

DESCRIPTION

General Technical Specifications

SP-50
DATE FILE NAME SHEET

Rear of Machine
1
OF

Voltage 208-240VAC, 50/60Hz, 1PH 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH 208-240VAC, 50/60Hz, 3PH Elec. Heat 380-460VAC, 50/60Hz, 3PH Elec. Heat

Phase System Wire Wire Size 1 2 + GND 14 3 3 + GND 14 3 3 + GND 14 3 3 + GND 4 3 3 + GND 10

Amps 8 5 3 48 24

Breaker 15 15 15 60 30

9-30-2013

SP-50GenSpec.cdr