You are on page 1of 1

A

Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 1PH 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH 208-240VAC, 50/60Hz, 3PH Elec. Heat 380-460VAC, 50/60Hz, 3PH Elec. Heat Phase System Wire Wire Size 1 2 + GND 14 3 3 + GND 14 3 3 + GND 14 3 3 + GND 4 3 3 + GND 10 Amps 14 8 4 52 26 Breaker 15 15 15 60 30

41.73 1059.94

Drain Requirements
Connection Size inches mm 3 76 Discharge Rate gal/min liters/min 62 235 Min Sewer Line inches mm 4 102
880.11

Water Requirements
Connection Size US Metric 3/4" DN 19 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 11 40 Minimum Supply Line Size US Metric 1 DN 25 Max Operating Pressure US Metric 125 PSI 8 Bar

54.24
1377.70

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1/2" DN 12 30-75 2-5 Minimum Supply Line Size US Metric 1/2" DN 12 Max Operating Pressure US Metric 100 PSI 6 Bar
REV

MOUNTING BOLT DETAIL


BY DATE REV. DESCRIPTION

Dynamic Load Specifications


Static floor load kN lbs 8.41 1890 Static pressure kN/m2 lbs/ft2 142 6.8 Total Dynamic Load kN lbs 4 909 Dynamic pressure kN/m2 lbs/ft2 68 3.3 Dynamic Frequency Hz 14.83

A1
DRAWN BY CHECKED BY

AFA

9-30-2013
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

A. Adcock 9-30-2013 C. Oswald 9-30-2013


DESCRIPTION

Shipping Data
Type Domestic Export lbs 1452 1584 kg 660 720 cu ft 73.3 73.3 cu m 2.1 2.1

General Technical Specifications

SP-65
DATE FILE NAME SHEET

Rear of Machine
1
OF

34.65

9-30-2013

SP-65GenSpec.cdr