You are on page 1of 1

A

Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 1PH 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH 208-240VAC, 50/60Hz, 3PH Elec. Heat 380-460VAC, 50/60Hz, 3PH Elec. Heat Phase System Wire Wire Size 1 2 + GND 12 3 3 + GND 12 3 3 + GND 12 3 3 + GND 3 3 3 + GND 8 Amps 31 18 9 78 39 Breaker 40 20 15 80 40

48.82
1240.03

Drain Requirements
42.52 1080

Connection Size inches mm 3 76

Discharge Rate gal/min liters/min 86 326

Min Sewer Line inches mm 4 102

64.74
1644.4

Water Requirements
Connection Size US Metric 1" DN 25 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 30 113 Minimum Supply Line Size US Metric 1-1/4 DN 32 Max Operating Pressure US Metric 125 PSI 8 Bar

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 3/4" DN 19 30-75 2-5 Minimum Supply Line Size US Metric 3/4" DN 19 Max Operating Pressure US Metric 100 PSI 6 Bar
REV

MOUNTING BOLT DETAIL


BY DATE REV. DESCRIPTION

Dynamic Load Specifications


Static floor load kN lbs 13.34 2999 Static pressure kN/m2 lbs/ft2 166 7.9 Total Dynamic Load kN lbs 6.9 1542 Dynamic pressure kN/m2 lbs/ft2 85 4.1 Dynamic Frequency Hz 13.75

A1
DRAWN BY CHECKED BY

AFA

9-30-2013
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

A. Adcock 9-30-2013 C. Oswald 9-30-2013


DESCRIPTION

Shipping Data
Type Domestic Export lbs 2400 2400 kg 1091 1091 cu ft 128.2 128.2 cu m 3.6 3.6

General Technical Specifications

SP-110
DATE FILE NAME SHEET

Rear of Machine
1
OF

9-30-2013

SP-110GenSpec.cdr