A

Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 1PH 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH 208-240VAC, 50/60Hz, 3PH Elec. Heat 380-460VAC, 50/60Hz, 3PH Elec. Heat Phase System Wire Wire Size 1 2 + GND 3 3 + GND 8 3 3 + GND 14 3 3 + GND 3 3 + GND Amps 32 16 Breaker 40 20

Drain Requirements
FRONT
BY

Connection Size inches mm 4 102

Discharge Rate gal/min liters/min 150 560

Min Sewer Line inches mm 5 127

Water Requirements
Connection Size US Metric 1" DN 25 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Flow Rate (@45PSI/3Bar) gal/min liter/min 30 113 Minimum Supply Line Size US Metric 1-1/4 DN 32 Max Operating Pressure US Metric 125 PSI 8 Bar

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 3/4" DN 19 30-75 2-5 Minimum Supply Line Size US Metric 3/4" DN 19
Total Dynamic Load kN lbs 8.4 1893

Max Operating Pressure US Metric 100 PSI 6 Bar


Dynamic Frequency Hz 12.78
REV DATE REV. DESCRIPTION

Dynamic Load Specifications


Static floor load kN lbs 14.88 3344 Static pressure kN/m2 lbs/ft2 149 7.1 Dynamic pressure kN/m2 lbs/ft2 85 4.0

A1
DRAWN BY CHECKED BY

AFA

9-30-2013
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

Shipping Data
Type Domestic Export lbs 3980 4070 kg 1809 1850 cu ft 190 190 cu m 5.4 5.4

Compressed Air
Connection Size US Metric 3/8" NPT Consumption US Metric 0.5 CFM 0.01 CMM Pressure US Metric 80-100 PSI 5.5-7 BAR