Professional Documents
Culture Documents
WinProp
Phase Property Program
Version 2010
This publication and the application described in it are furnished under license exclusively to the licensee, for internal use only, and are subject to a confidentiality agreement. They may be used only in accordance with the terms and conditions of that agreement. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, or otherwise, including photocopying, recording, or by any information storage/retrieval system, to any party other than the licensee, without the written permission of Computer Modelling Group. The information in this publication is believed to be accurate in all respects. However, Computer Modelling Group makes no warranty as to accuracy or suitability, and does not assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change without notice.
The license management portion of this program is based on: Reprise License Manager (RLM) Copyright (C) 2006-2010, Reprise Software, Inc WinProp uses Intel(R) Compilers. WinProp, CMG, and Computer Modelling Group are registered trademarks of Computer Modelling Group Ltd. All other trademarks are the property of their respective owners. Computer Modelling Group Ltd. Office #150, 3553 - 31 Street N.W. Calgary, Alberta Canada T2L 2K7
E-mail: cmgl@cmgl.ca
Preface
WinProp is CMG's equation of state (EOS) multiphase equilibrium and properties determination program. WinProp features techniques for characterizing the heavy end of a petroleum fluid, lumping of components, matching laboratory PVT data through regression, simulation of first and multiple contact miscibility, phase diagrams generation, asphaltene and wax precipitation modelling, compositional grading calculations as well as process flow simulation. This User's Guide presents a comprehensive description of the steps involved in obtaining a PVT data suitable for inclusion in data files for CMG's GEM, STARS or IMEX simulators. This User's Guide is aimed at reservoir engineers who want to use WinProp to predict phase behavior of reservoir fluids as well as characterize these fluids for reservoir simulation. It requires some knowledge of phase behavior as it pertains to the different fluid types found in reservoirs. Every attempt has been made in the preparation of this User's Guide to provide the user with all the necessary details. If questions arise, please contact: Computer Modelling Group Ltd.
#150, 3553 31 Street N.W. Calgary, Canada T2L 2K7 Telephone: (403) 531-1300 Fax: (403) 289-8502 E-mail: cmgl@cmgl.ca
Confidentiality: All components of CMG technology including software and related documentation are protected by copyright, trademark and secrecy. CMG technology can be used only as permitted by your license from CMG. By the license, you have agreed to keep all CMG technology confidential and not disclose it to any third party. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, or otherwise, including photocopying, recording, or by any information storage/retrieval system, to any party other than the licensee, without the written permission of Computer Modelling Group. Corrections/Errors: CMG ENDEAVORS TO PRODUCE TECHNOLOGY OF THE HIGHEST
QUALITY; NEVERTHELESS ERRORS OR DEFICIENCIES IN SUCH TECHNOLOGY ARE INEVITABLE. IF YOU FIND AN ERROR OR DEFICIENCY, YOU ARE REQUESTED TO PROVIDE DETAILS OF IT AND ILLUSTRATIVE DATA SET(S) TO CMG SUFFICIENT TO PERMIT CMG TO REPRODUCE THE ERROR OR DEFICIENCY. CMG SHALL ENDEAVOR TO REMEDY A DEFICIENCY IN A TIMELY MANNER AND SHALL PERIODICALLY REPORT TO YOU AS TO THE STEPS BEING TAKEN TO REMEDY THE DEFICIENCY. THE RESPONSE TIME FOR A DEFICIENCY MUST BE PRIORITIZED FOR THEIR GENERAL APPLICATION TO CMG MEMBERS AND WHETHER THEY FORM PART OF A CMG PROGRAM. CMG DOES NOT WARRANT THAT DEFICIENCIES WILL BE REMEDIED.
Limited Liability: CMG does not warrant the accuracy or usefulness of the technology and software - Refer to your license.
Contents
New Features 1
New Features in WinProp 2010.10...............................................................................1 New Features in WinProp 2009.10...............................................................................1 New Features in WinProp 2008.10...............................................................................2 New Features in WinProp 2007.10...............................................................................2 New Features in WinProp 2006.10...............................................................................3 New Features in WinProp 2005.10...............................................................................3 New Features in WinProp 2004.10...............................................................................4 New Features in WinProp 2003.11...............................................................................4 New Features in WinProp 2003.10...............................................................................5 New Features in WinProp 2002.10...............................................................................6 New Features in WinProp 2001.10...............................................................................6 New Features in WinProp 2000.15...............................................................................7 New Features in WinProp 2000.10...............................................................................8 New Features in WinProp 1999.10...............................................................................9 New Features in WinProp 98.00.................................................................................12 New Features in WinProp 97.00.................................................................................14
Introduction
17
What is WinProp?.......................................................................................................17 Use of this Manual......................................................................................................18 Installation ..................................................................................................................18 Confidentiality ............................................................................................................18 Template Data Files ....................................................................................................19
Tutorial Section
21
Overview.....................................................................................................................21 Getting On-Line Help .................................................................................................21 Creating, Opening and Saving Data Files...................................................................21 Running, Viewing Output and Creating Plots ............................................................22 Copying Between Different Data Files.......................................................................23 Setting Up a Regression Run ......................................................................................23
Contents i
Using the Update Component Properties Feature of WinProp................................... 23 View the Keyword Data File Created by WinProp .................................................... 24 Selecting a User-Defined Editor................................................................................. 24 Editing the Data Set.................................................................................................... 24 Table Import Wizard .................................................................................................. 25 Overview ....................................................................................................... 25 Using the Table Import Wizard..................................................................... 26
31
Titles/EOS/Units Selection
33
Overview .................................................................................................................... 33 Data Input ................................................................................................................... 33 Comments...................................................................................................... 33 Title 1, Title 2, Title 3 ................................................................................... 33 Equation of State ........................................................................................... 34 Units .............................................................................................................. 34 Feed ............................................................................................................... 34
Components
35
Component Selection and Definition ......................................................................... 35 Library Components...................................................................................... 35 User Component with Known Properties...................................................... 36 User Component with Known SG, Tb and MW ............................................ 37 Component Properties ................................................................................................ 38 Notes on Component Properties.................................................................... 39 Interaction Coefficients .............................................................................................. 43 Hydrocarbon-Hydrocarbon Interaction Coefficients..................................... 44 Other Interaction Coefficients ....................................................................... 46 Viscosity Parameters .................................................................................................. 46 Jossi-Stiel-Thodos Correlation ...................................................................... 46 Pedersen Correlation ..................................................................................... 47 Aqueous Phase ........................................................................................................... 48 Aqueous Phase Salinity ................................................................................. 48 Henrys Law Constant Correlation................................................................ 49 Activation of Second Set of Component Properties................................................... 49 GEM Fluid Model Generation and Component Properties Printing .......................... 50 Importing Components with the Table Import Wizard .............................................. 51
ii Contents
53
Overview.....................................................................................................................53 Composition Specification..........................................................................................53 Initial K-Values...........................................................................................................55 Output Level ...............................................................................................................55 Stability Test Level.....................................................................................................55
57
Overview.....................................................................................................................57 Saturation Pressure .....................................................................................................57 Saturation Temperature...............................................................................................58 Phase Boundary and Quality Line Calculations .........................................................58 Envelope Specification ..................................................................................59 Envelope Construction Controls ....................................................................61 Cricondenbar/Cricondentherm Calculation ................................................................62 Critical Point Calculation............................................................................................62
Flash Calculations
63
Overview.....................................................................................................................63 Common Input for Two-Phase Flash, Multiphase Flash and Asphaltene/Wax Modelling Calculations...............................................................................................63 Two-Phase Flash Calculations....................................................................................64 Multiphase Flash Calculations....................................................................................64 Asphaltene/Wax Modelling ........................................................................................65 Theoretical Background.................................................................................65 Input Data - Asphaltene/Wax Modelling.......................................................67 Single-Phase Calculation ............................................................................................70 Isenthalpic Flash Calculations ....................................................................................70 Theoretical Background.................................................................................70 Input Data - Isenthalpic Flash ........................................................................72
73
Background.................................................................................................................73 Input Data ...................................................................................................................73 Envelope Specification Tab ...........................................................................73 Envelope Construction Controls Tab.............................................................75 Initial K-Values Tab ......................................................................................76
Contents iii
77
Overview .................................................................................................................... 77 Characterization of Multiple Related Samples........................................................... 78 Splitting the "Plus" Fraction....................................................................................... 78 Importing Extended Analysis Data with the Table Import Wizard............................ 82 Numerical Cleaning of Mud-Contaminated Samples................................................. 83 Lumping of Components............................................................................................ 84 Transferring Results to Other Data Sets ..................................................................... 85
Laboratory Calculations
87
Overview .................................................................................................................... 87 Recombination of Separator Oil and Gas................................................................... 87 Compressibility Calculation ....................................................................................... 90 Constant Composition Expansion .............................................................................. 90 Differential Liberation................................................................................................ 92 Constant Volume Depletion ....................................................................................... 94 Separator Test............................................................................................................. 97 Swelling Test............................................................................................................ 101 Importing Laboratory Experiment Data with the Table Import Wizard................... 103
105
Regression
111
Overview .................................................................................................................. 111 Organization of the Input Data ................................................................................. 111 Parameter Selection.................................................................................................. 112 Automatic Regression Parameter Selection ............................................................. 114 Grouping Regression Variables................................................................................ 114 Regression Variable Bounds .................................................................................... 115 Regression Control Parameters ................................................................................ 116 Transferring Results to Other Data Sets ................................................................... 116
Compositional Grading
119
iv Contents
123
Overview...................................................................................................................123 Use of the STARS PVT Generation Option .............................................................123 Input Data (STARS) .................................................................................................124 Basic STARS PVT Data ..............................................................................124 Gas-Liquid K-Value Tables.........................................................................126 Gas-Liquid and Liquid-Liquid K-Value Tables ..........................................127 Gas-Liquid and Solid-Liquid K-Value Tables.............................................128 Feed and K-Value Plotting Controls............................................................129
Process Flow
131
135
References
149
List ............................................................................................................................149
Appendix A
153
Case Studies..............................................................................................................153 Case Study Number 1: Gas Condensate Modelling....................................153 Case Study Number 2: Solubility of CO2 in Brine .....................................163 Case Study Number 3: Asphaltene Precipitation Modelling ......................174
Appendix B
183
Equations ..................................................................................................................183 Cubic Equation of State ...............................................................................183 Phase Stability Test......................................................................................188 Two-Phase Flash Calculation ......................................................................190 Saturation Calculation..................................................................................191 Cricondenbar/Cricondentherm Equations....................................................193 Phase Diagram Construction .......................................................................193 Three Phase Flash Calculation with Equation of State ................................197 Three Phase with Isenthalpic Flash Calculation ..........................................198 Flash Calculation Involving Water ..............................................................200
Contents v
Critical Point Calculations........................................................................... 203 Viscosity Correlation................................................................................... 204 Solution of Non-Linear Equations .............................................................. 206 Plus Fraction Characterization .................................................................... 207 Interfacial Tension Calculations.................................................................. 211 Regression ................................................................................................................ 211 Introduction ................................................................................................. 211 The Regression Method............................................................................... 212 Application of the Regression ..................................................................... 213 Properties of Components ........................................................................................ 216 User Components ........................................................................................ 218 Interaction Coefficient................................................................................. 220 Nomenclature ........................................................................................................... 222 References for Appendix B ...................................................................................... 224
vi Contents
New Features
2 New Features
Other Enhancements for IMEX PVT Table Generation For all IMEX PVT tables, the user can now choose to generate gas formation volume factors, gas expansion factors, or gas Z-factors. This applies to the saturated tables (PVT, PVTG, PVTCOND and PVTVO) as well as the undersaturated gas tables, which can now take the form BGUST, EGUST or ZGUST. For IMEX PVTCOND and PVTVO tables, calculation of the condensate/gas ratio at low pressures has been modified for improved performance in the simulator. Scaling Differential Liberation Oil FVF and GOR to Bubble Point Oil Volume For the differential liberation experiment, oil formation volume factor and solution gas/oil ratio can be scaled to the bubble point oil volume rather than the residual oil volume. This provides oil shrinkage and cumulative gas released per volume of bubble point oil, and eliminates the need for the EOS to accurately represent the residual oil volume. The scaled values can be used in regression. Summary plots show both the original data and the scaled values. STARS PVT Generation For STARS PVT generation, new methods have been implemented to generate the component liquid viscosity table. Apparent liquid viscosities of light components can be generated by perturbing the dead oil at each temperature, which will give accurate liquid viscosities of solvent components which may vaporize at higher temperatures ("match dead oil" method). Smooth curves for all component viscosities may be generated by scaling the liquid viscosities at low temperatures, then extrapolating to higher temperatures ("scale viscosities" method). More accurate determination of phase viscosity and density, and reduced sensitivity to choice of reference condition, have been achieved by using stable liquid properties in STARS component property calculations. Saturation Pressure/Regression Enhancement Saturation Pressure calculation results are checked for stability. This prevents the regression algorithm from converging to an unstable two-phase saturation condition, within a three-phase region.
New Features 3
Oil-Gas-Water (OGW) Flash Calculations The OGW flash has been improved to give greater stability and better convergence characteristics for difficult problems, for example light and intermediate hydrocarbons with steam. STARS Aqueous-Liquid and Aqueous-Vapor K-Value Generation In addition to the improvements of the OGW flash listed above, the generation of STARS Kvalues including aqueous phases has been enhanced with improved extrapolation algorithms.
4 New Features
Separator Calculation for Gas Condensates Calculation of dry gas and wet gas formation volume factors has been implemented when the separator calculation is used with gas condensate fluids. The dry gas FVF is defined as the volume of gas at the dew point pressure divided by the volume of gas from all separator stages evaluated at standard conditions. The wet gas FVF is defined as the volume of gas at the dew point pressure divided by a hypothetical surface wellstream volume, calculated under the assumption the entire wellstream is in the gas phase with a Z-factor of one. The condensate/gas ratio is also reported. In addition, the average separator gas gravity from all separation stages is now being output for oil and condensate fluids.
New Features 5
6 New Features
New Features 7
Interface Enhancements The differential liberation and constant volume depletion experiment data entry forms have been redesigned to allow entry of pressure step data in row format, for improved compatibility with experimental PVT reports. Data for material balance and consistency check calculations is now entered on a separate table which is linked to the main table with the pressure information. Pasting of data to any grid which allows a variable number of rows has been modified to automatically increase the number of rows in the table if required to hold all of the data being input.
Interface Enhancements A feature has been added to allow calculation options to be temporarily excluded from the data set, rather than deleting them entirely. Options are excluded/included from the main control form by right-clicking on the desired row and making a selection from the pop-up menu. One application of this feature is to temporarily reduce the number of calculation options within a regression block to try and obtain a match to some key data. After an initial regression run, the component properties can be updated and calculation options that were excluded can be included again for further regression runs. Data entry and navigation on the grids has been improved by enabling use of the left and right arrow keys, in addition to the up, down and enter keys.
New Features 9
Generation of PVT Properties for CMGs IMEX Simulator WinProp can now generate the PVT data corresponding to the light oil and the pseudomiscible models of CMGs IMEX simulator. Earlier releases targeted the black oil model only. In addition, the aqueous phase properties can now be estimated from built in correlations as an alternative to entering the values directly. The PVT fluid model data with the associated IMEX keywords is written to an output file with the extension (.imx). This file can be referenced as an include file in an IMEX data file. Please refer to the IMEX PVT data generation chapter of this manual for a complete discussion. Consistency Checks and Material Balance Calculations A number of tools are available in WinProp for evaluating the quality of PVT data provided to the reservoir engineer from laboratory or field measurements. The data is typically used to tune the EOS model. It is imperative therefore that the PVT data is analyzed critically prior to any detailed regression calculations. The tools available include Hoffman plots and material balance calculations. Material balance calculations for the constant volume depletion (CVD), differential liberation (DL) and separator options are performed if the required data is entered. For these experiments, the required data are generally reported in a typical PVT report from a laboratory. A Hoffman plot is generated for the recombination option based on the entered oil and gas compositions. Hoffman plots are also created with the CVD, DL and separator options if sufficient data is entered to calculate the oil phase compositions from a component material balance. Refer to the chapter on Laboratory Calculations for more detail as well as template cases matbal-bo.dat and matbal-gc.dat. Changes to the Multiple Contact Miscibility (MCM) Option A number of enhancements have been made to the MCM option with the objectives of 1) alleviating difficulties in interpreting the program results and 2) determining and reporting multiple and first contact miscibility pressures directly. With respect to point one, the criteria used for stopping the forward and backward contact flash calculations are reported in the output file. The most likely reasons are either miscibility is achieved or there is no change in the oil and gas compositions from the previous contact. With respect to point two, the user can now enter a range of pressures for the calculation. If multiple and/or first contact miscible pressure(s) are found in this pressure interval then these values are reported at the end of the output listing. Ternary diagrams are also automatically created at designated intervals. Specification of Mole Fraction Steps for Flash Calculations The ability to specify steps in the primary mole fraction making up the feed to a flash calculation has been implemented for two-phase, multiphase and asphaltene/wax flash calculations. This allows the specification of flashes for a number of mixtures of the primary and secondary compositions on a single flash form. This feature is similar to the existing capability for specifying pressure and temperature steps. These steps can be defined with the feed specification on the first tab of each flash calculation.
10 New Features
Plotting Capability Added to Two-Phase and Multiphase Flash When a series of flash calculations have been specified by setting temperature, pressure or mole fraction steps, plots of the phase properties can be generated. Up to three phase properties, such as molecular weight, compressibility factor or phase mole fraction, can be selected for each flash calculation. One plot is generated for each property and each phase. When plotting is activated, steps can be specified in one or two of the variables: pressure, temperature and mole fraction. If steps are specified for only one variable, the plots are generated with that variable as the independent variable, and the phase property as the dependent variable. Up to 100 steps in the independent variable are allowed. When steps are specified for two variables, one variable is treated as a parameter variable, and curves of the phase property are displayed for each value of the parameter variable. Up to 8 steps in the parameter variable are allowed. The phase properties to be plotted are selected on tab Plot Control of the flash calculation forms. Plotting Capability Added to Asphaltene/Wax Flash The asphaltene/wax flash has a plotting feature similar to the one described above for the two-phase and multiphase flashes. This allows generation of plots such as weight % precipitate as a function of solvent concentration or pressure. A special plotting feature implemented for the asphaltene/wax flash is the generation of a pseudo-ternary diagram to display the results of flash calculations in terms of the predicted phase split, i.e. liquid-vapor, solid-liquid etc. The results are shown for a number of dilution lines defined by the user. Plot specification is done on tab Plot Control of the asphaltene/wax flash calculation. Three-Phase Envelope Automatic Plot Generation Automatic plot generation has been implemented for the three-phase boundary calculation. Excel plots can now be created for three-phase P-T, P-X and T-X diagrams. These plots can be created by selecting File|Create Excel plots after running a data set with a three-phase envelope calculation option. Ternary Diagram Two-Phase Envelope Generation The capability to create ternary or pseudo-ternary two-phase boundaries has been added to the two-phase envelope calculation option. This calculation locates points in composition space defining the two-phase vapor-liquid phase boundary on a triangular diagram. This can be considered a static or single-contact calculation, as opposed to the multiple contact calculation option which performs a dynamic simulation of multiple contact miscibility processes. This feature is enabled by selecting Pseudo-Ternary Phase Envelope on the Two-phase envelope calculation option form. Table Import Wizard A Table Import Wizard has been implemented in WinProp to assist the user in importing data into WinProp from existing Excel or ASCII format files. The wizard guides the user through the steps of selecting data to be imported, defining units and performing unit conversions, and inserting the imported data into the correct locations in WinProps data structure. Table import is available for the following forms: Component Selection/Properties, Plus Fraction Splitting, Constant
User's Guide WinProp New Features 11
Composition Expansion, Differential Liberation, Constant Volume Depletion and Swelling Test. An example illustrating the use of the Table Import Wizard is given in the Tutorial section of the manual. Information regarding the specific implementation for the forms listed above may be found in the Components, Component Splitting and Lumping, and Laboratory Calculations sections. Interface Enhancements Two toolbars are provided for easier access to items previously available through the menus alone. The main toolbar contains buttons corresponding to items in the File and Edit menus. This toolbar targets frequently performed tasks such as opening and saving files, generating the results, viewing the output file and creating plots. This toolbar is not customizable and is permanently displayed. A second toolbar contains buttons corresponding to often used calculation options. These buttons are grouped to mirror the organization of the menus. This toolbar is customizable. The user can remove any of the buttons selected by default and add buttons corresponding to options not originally chosen. Once the toolbar is customized the settings are saved for subsequent sessions. The options toolbar can also be removed from the interface and reinstituted at a later time. The menu system is revised with the objective of creating more intuitive classes. Similarly, the names of the forms corresponding to the calculation options are modified to be more descriptive. Forms for the constant volume depletion, separator test and differential liberation are redesigned in light of the additional data that can now be entered for material balance calculations. Other enhancements include the addition of progress bars in specific situations. A progress bar is shown when loading or saving the component form for example.
12 New Features
Generation of PVT Properties for IMEX Black Oil Model WinProp can now generate the PVT data corresponding to the black oil model of CMGs IMEX simulator. This data is written out to an output file with the extension blk. This file can then be referenced as an include file in an IMEX data file. The properties of the oil phase (formation volume factor, gas oil ratio) are generated by flashing the equilibrium liquid at each stage of the differential liberation directly through the user specified separator train. The range of the PVT table can be extended to include pressures above the original oil bubble point pressure by generating the swelling curve. This way the table can handle variable bubble point scenarios arising for example from gas injection or solution gas migration followed by repressurization. This option can be found under Options | "Black oil model PVT data." Please refer to the Black oil PVT data generation chapter of this manual for a complete discussion. Process Flow and Isenthalpic Flash Options Data entry forms for the Process flow and Isenthalpic flash options have been added to WinProp. The process flow option can be added to the data file by selecting Calculations | Process flow from the menu and isenthalpic flash by selecting Calculations | Isenthalpic flash. For the process flow sample template are process1.dat, process2.dat and process3.dat. For isenthalpic flash the sample templates are isenth1.dat, isenth2.dat and isenth3.dat. Please refer to the chapter titled Process flow for detailed discussion of the process flow option and the Flash calculations chapter for more details on the isenthalpic flash option. Support for Multiple Hydrocarbon-Hydrocarbon Binary Interaction Exponents Hydrocarbon components are identified by a value of 1 on the HC column of the component table on the Component form. Binary interaction coefficients between two hydrocarbon components are calculated from a correlation, which involves the critical volume of each component and an exponent parameter. In contrast to previous versions of WinProp where all HC-HC binaries were calculated based on a single exponent parameter, the user can now group pairs of binary and specify a different exponent parameter value for each group. These individual group exponents can be also selected as regression parameter(s). Please see the chapter entitles Components and Regression for more details. Handling of the Regression Block in a Data File In WinProp the regression block refers to the calculation options that are between the Regression and Start regression forms. For a case to run successfully all options in this block must have at least one piece of experimental data entered and all options outside the regression block are required not to have any experimental data entered. WinProp will now attempt to ensure that these requirements are met when the user attempts to run a given case while preserving the data that has been entered. For example if there an option within the regression block then this option will be moved out of the regression block. If there is an option with experimental data outside the regression block then the experimental data will be written out to the data file with the accompanying keyword(s) commented out. This will also allow the user to retain the experimental data that were entered for regression when regression is removed from the data file, that is Regression and End regression forms are removed. The entered experimental data will be shown where appropriate with the program predictions on plots even if there is no regression involved in the run.
New Features 13
Interface Enhancements The list of the five most recently files accessed by WinProp is now available on the File menu. This is a faster way of selecting a case than through the file open dialog box. Interface enhancements include the ability to redirect the screen diary to an output file. To redirect select Redirect to file DBPROP.XXX under File | Screen menu. The user can now select an editor other than Notepad by invoking the Editor | User editor select option under the File menu. This will open a file dialog box. Using the file dialog select the executable file corresponding to the desired editor. WinProp allows up to open up to 8 different cases (data files) to be open simultaneously, primarily to allow various calculation option forms to be copied between different data files. This saves the user from having to type in data values multiple times. The MDI capability also facilitates comparing the data entered for a given form across data files. A number of checks have been implemented to avoid violating the internal design limitations of this option. For example forms can be opened only when a single case is loaded and a case cannot be closed until all the open forms are closed. In previous versions of WinProp the data in a table (grid) could be changed via a text box positioned outside the table. With WinProp 98.00 a floating text box positioned exactly on the desired cell is used for table (grid) edits. To erase the current value or text in a cell and enter a new value or text, position the cursor on that cell and start typing. To edit the contents of a cell, position the cursor on that cell and double click with the left mouse button. The cell contents are updated when the carriage return (Enter) key is pressed or if the cursor is moved to another cell. Please note that changing the focus to a new control will not update the grid (table) contents.
14 New Features
Regression Enhancements It is now possible to specify more than one component for a given property such as the critical pressure as a single variable in regression. The members of the group will in general have individual initial values and bounds. In regression the same increment is applied to all members of the group. This feature can be useful if it is desired to maintain a certain trend or symmetry for a given property or in avoiding regressing on a property belonging to a component with a small mole fraction. For information on how to define group variables refer to the Regression chapter of this manual. Summary plots showing before regression, after regression and experimental data are now generated automatically when Excel plots are created from a regression run. Individual plots showing calculated results are still available, with new titles indicating before or after regression calculations. Conversion from CMGPROP to WinProp Format A conversion utility is provided within WinProp to translate files created for CMGPROP on UNIX or PC platforms. This utility can be invoked by selecting Options|Convert from Cmgprop to WinProp. The user is advised to open each form and verify the results of the conversion carefully. Please use the Save As option under the File menu to save the WinProp compatible data file to avoid overwriting the original CMGPROP data file. The original file will be an important aid in case difficulties are encountered in conversion and in verifying the conversion. There are a number of situations that can pose difficulties for the converter including the use of wildcards in specifying array values and presence of comment marker on a line where array values are stipulated. Please edit the CMGPROP data file eliminating these situations prior to using the conversion utility. MDI Capability The Multiple Document Interface (MDI) Feature is now implemented in WinProp. This allows the user to open up to eight files at once. This has significant advantages for example when the user desires to compare output files for two or more cases or in the ease with which data corresponding to various calculation options may be copied between different data files. Refer to the section copying between different data files under the Tutorial chapter of this manual. Update Component Properties Feature Upon completing a splitting, lumping or regression calculation where the number of components are changed or the component properties modified, WinProp writes out the revised component information in an output file with the suffix .rls. With the previous version of WinProp the user would run a file, for example test1.dat with a splitting calculation, use File|Open to open test1.rls, use File|Save As to rename to test2.dat for example and then continue working with this file by appending calculation options to it. This procedure is now automated with the introduction of the update component properties selection under the Options menu. The user still runs the splitting calculation with test1.dat. Once the calculation is carried out, update component properties is invoked. This updates the information on the Composition and Component forms. The user then removes the splitting calculation from the data file and appends the desired calculation options. Optionally the user may wish to save this file with a different file name say test2.dat to retain a complete work record of the session.
New Features 15
Addition of Bounds Tab on the Regression Form An additional tab showing the initial value and the lower and upper bound selected by WinProp for each regression variable specified has been added to the Regression form. The user may subsequently edit the bounds. The capability to restore values back to their default selections is provided as well. This provides the user greater flexibility in arriving at an EOS description based on the specific characteristics of the fluid being considered and the PVT data available. Volume Shift Specification Additional flexibility is introduced in selecting values for the volume shift parameter for each component. Previously the default was a value of zero for all components. The new default is a value generated from the correlation for library components and a value of zero for user defined components. The user may apply the correlation values to all components by selecting Reset to Correlation Values from the Volume Shift menu on the component form. Alternatively the user may revert to the older default by selecting Reset to Zeros. The user can still specify a value for any component which is different from either correlation or zero by editing the cell directly. Support of Two Sets of EOS Parameters WinProp now supports the concept of two different EOS models. When two sets are enabled the first set is used for calculations at reservoir conditions and the second set for surface or separator conditions. With this provision it is possible to match PVT experimental data at surface conditions (typically separator API and GOR data) independently from data at reservoir conditions. This makes it possible to obtain much more accurate predictions over the wide range of conditions encountered as the fluid is produced and processed on the surface with a realistic number of components for compositional simulation. Please refer to the Component and Regression chapters for details. Extended Separator Option The conventional separator operation involves the liquid phase output from a given separator becoming the feed for the next separator in sequence downstream and the vapor phase joining the gas product stream. This arrangement is not always optimal particularly for rich gas condensates. For modeling alternative separation strategies the separator option is enhanced to allow additional product streams such as LPG and in providing flexibility in the selection of the destination of the liquid and vapor stream from each separator. Please review the section on separator calculation in chapter Laboratory Calculations for more information of this feature. Multicomponent Solid Precipitation Model The solid precipitation model is now suitable for modeling both wax and asphaltene precipitation scenarios. The thermodynamic model has been enhanced as follows: the precipitate is now modeled as a multicomponent solid in contrast to the earlier single component pure solid phase assumption, non-isothermal conditions are treated, and up to three fluid phases in equilibrium with the solid are allowed.
16 New Features
Introduction
What is WinProp?
Welcome to WinProp, the Windows version of CMGPROP. WinProp is CMG's equation of state multiphase equilibrium property package featuring fluid characterization, lumping of components, matching of laboratory data through regression, simulation of multiple contact processes, phase diagram construction, solids precipitation, and more. Laboratory experiments considered in WinProp include recombination of separator oil and gas, compressibility measurements, constant composition expansion, differential liberation, separator test, constant volume depletion and swelling test. You can use WinProp to analyze the phase behavior of reservoir gas and oil systems, and to generate component properties for CMG's compositional simulator GEM, black oil simulator IMEX and steam and additives thermal simulator STARS. WinProp contains a graphical interface that allows you to prepare data, run the phase property calculation engine, view the output with an editor, and create plots with Excel. WinProp creates keyword data files to drive the phase behavior calculation engine. Besides the regular keywords that were required by the CMGPROP program, these data files contain special control character strings for the graphical interface. A conversion utility is provided within WinProp for users who have been using CMGPROP on a UNIX platform or on the PC to facilitate the migration to WinProp.
Introduction 17
Installation
All CMG software must be installed from the CD-ROM by running the Setup program. Please refer to the detailed installation instructions that are packaged with the software for additional information.
Confidentiality
All components of CMG's technology including software and related documentation are protected by copyright, trademark and secrecy. CMG technology can be used only as permitted by your license from CMG. By the license, you have agreed to keep all CMG technology confidential and not disclose it to any third party. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic, mechanical, or otherwise, including photocopying, recording, or by any information storage/retrieval system, to any party other than the licensee, without the written permission of Computer Modelling Group Ltd.
18 Introduction
mcm-condensing.dat mcm-vaporizing-co2.dat mcm-combined-H95-8lean.dat mcm-combined-U2002rich.dat mcm-Z12-5-MME.dat process-cvd.dat process-mcm.dat process-plant.dat recombine.dat regress-blackoil1.dat regress-blackoil2.dat regress-compress.dat regress-condensate1.dat regress-condensate2.dat regress-critical.dat regress-flash_2ph.dat regress-flash_3ph.dat regress-flash_ogw.dat regress-lightoil.dat regress-multicontact.dat regress-sat_pres.dat regress-separator.dat regress-singlephase.dat regress-viscosity.dat sat-pressure.dat sat-temperature.dat separator.dat singlephase.dat solid-asph_plots.dat solid-asph1.dat solid-asph2.dat solid-phenanthrene.dat solid-wax.dat split-mw_analysis.dat split-mwsg_analysis.dat split-mwsg_plus.dat split-mwsgtb_analysis.dat stars-comp_props.dat stars-vl_kvalues.dat stars-vlaq_kvalues.dat stars-vls_kvalues.dat swelling.dat
Condensing gas drive multicontact miscibility calculation Vaporizing CO2 drive multicontact miscibility calculation Condensing and vaporizing combined drive MMP calculation Condensing and vaporizing combined drive MMP calculation Condensing and vaporizing combined drive MME calculation Process flow simulation of constant volume depletion test Process flow simulation of multiple contact experiment Process flow simulation of a gas plant Recombination of separator oil and gas streams Black oil no. 1 regression Black oil no. 2 regression Liquid compressibility regression Gas condensate no. 1 regression Gas condensate no. 2 regression Critical point regression Two-phase flash regression Three-phase EOS flash regression Three-phase Henry's law flash regression Light oil regression Multiple contact data regression Saturation pressure regression Separator data matching with 2nd EOS set parameters Single phase properties regression Regression for viscosity matching Saturation pressure calculation Saturation temperature calculation Separator calculation Single-phase fluid properties calculation Plot construction for single component asphaltene model Single component solid asphaltene precipitation Heavy oil with 2 component solid precipitation Pure component solid (phenanthrene) precipitation Multicomponent wax precipitation Characterization - MW versus mole fraction data Characterization - MW, SG versus mole fraction data Characterization plus fraction MW and SG only Characterization - MW, SG ,TB versus mole fraction data Component PVT properties generation for STARS Vapor -Liquid K-values generation for STARS Vapor -Liquid-aqueous K-values generation for STARS Vapor -Liquid-solid K-values generation for STARS Swelling experiment simulation
20 Introduction
Tutorial Section
Overview
This chapter includes information on the mechanics of creating, editing, saving and running data sets in WinProp, as well as viewing the output files and creating plots. Example case studies with step-by-step instructions for performing some PVT modelling tasks are described in Appendix A. Detailed instructions for using all of the calculation options available in WinProp are given in the remaining chapters.
The help on current form can be also invoked by pressing the function key F1
Tutorial Section 21
Description ASCII file containing calculation results. Output of component properties in a format suitable for the compositional simulator GEM. Output of composition versus depth data in format suitable for inclusion within the GEM simulator data file. Output of PVT data in format suitable for inclusion within STARS simulator data file. Output of the black oil, light oil or pseudo-miscible model PVT data in format suitable for inclusion within the IMEX simulator data file or extended black oil tables in a generic format. Output of component properties from the regression or lumping and splitting procedure. Output for plotting. Excel file containing data and plots that are created from an .srf file.
The results are written to files with the (.out) suffix. When you invoke the regression or lumping or splitting procedures, WinProp also creates a file with the suffix (.rls.) This file can be opened to create a new data set (see Chapters on Component splitting and lumping and Regression). If you select the component printing option for CMGs compositional simulator GEM on the form CMG GEM EOS Model, the component properties are printed to a file with the suffix (.gem) in a format suitable for GEM. If the CMG STARS PVT Data option is selected then an output file with the suffix (.str) is created. If the Write GEM *ZDEPTH checkbox on the Compositional Gradient form is checked off then the composition versus depth information is written out to a file with the suffix (.gmz.). If the calculation option to generate PVT data for simulation studies with IMEX is included in the data set then a file with the suffix (.imx) is created. This file contains PVT data in a format compatible with IMEX and can be referenced as an include file in an IMEX data file. Select File|Exit to exit WinProp.
22 Tutorial Section
Certain calculation options will create data for plotting. The plot information is in the (.srf) file. To create these plots with Excel, select File|Create Excel plots (or type F4). WinProp has its own Excel templates and macros to invoke Excel and generate the corresponding plots. These Excel plots are saved in an (.xls) file. If no plot data are available, a message will be issued. To view an Excel plot that you have already created with WinProp, select File|View Excel plots.
1. Set up the splitting calculation. Add the form for performing the splitting calculation to the WinProp data file. Open the Component Selection/Properties form. The compositional analysis up to C5 involves components with known properties. Add these components by selecting Add Component|LibraryComponent. Open the Composition form and enter the mole fractions as they appear on the laboratory report. Ignore the warning message about the sum not being equal to one. Open the Plus Fraction Splitting form and enter data for the plus fraction. 2. Run WinProp with the data file from step 1. Once the splitting calculation is performed WinProp writes out the full set of component properties including data for the pseudo-components in a special output file with the suffix (.rls). Open the File menu and select Update component properties option. WinProp will then read the (.rls) file and update the Composition and Component Selection/Properties forms based on the data in this file. 3. Remove the splitting form from the data set by highlighting the splitting calculation row on the data set structure form and selecting Edit|Cut from the menu. Proceed to set up the regression run as described in the section Setting up a regression run.
24 Tutorial Section
Undo Cut
Copy Paste
This will undo the previous edit function. This menu item is not available if there is nothing to undo. This option will cut the options and the data associated with them into the Clipboard. You cannot cut the Titles/EOS/Units or the Component Selection/Properties forms. This option will copy the options and the data associated with them into the Clipboard. This option will paste the data from the Clipboard into the current data set.
You can use the Copy and Paste option to transfer information and calculation options within one WinProp data set or from one data set to another. Editing Tables On many forms, you enter data into tables (or grids). For most tables, you can use the menu item Table to insert a new row or delete rows. You can highlight the data in different cells with the left mouse button. You can delete, cut and paste data corresponding to the highlighted cells with the standard Windows keystrokes: DELETE for delete, CTRL+C for copy, CTRL+X for cut, and CTRL+V for paste. Note that DELETE clears the data in cells, but does not delete the corresponding rows. Please use Table|Delete rows if you want to delete rows.
Tutorial Section 25
6. Unit conversions can be performed on the table before importing it into WinProp. Unit systems can be selected for the entire table. Units can also be selected for individual columns.
Click on Next to continue. Step 2: Choose a worksheet This step appears as step 2 if an Excel spreadsheet was selected in Step1. Since a spreadsheet can have several worksheets, this step requires the identification of the worksheet that contains the data to be imported. The worksheets are listed in a list box at the top right corner. Once a worksheet is highlighted, data from that worksheet is displayed as in the example below.
26 Tutorial Section
Click on Next to continue. Step 4: Select regions to be imported and define column names Step 3 is relevant only when importing from ASCII files and is skipped since this example involves importing from a spreadsheet. In step 4, the regions from the original table to be imported are identified and names are defined for all imported columns. Multiple ranges of columns can be selected, but a common set of rows must be selected for all columns. Before selecting the data, the table rows and columns can be transposed. If your data is in row-wise format, it can be transposed to allow definition of data types by column, as required by the table import wizard. Column names are selected by clicking on the right mouse button at the column header. This brings up a pop-up menu containing the available column names. Select the name that corresponds to the column from the menu. In the view of Step 4 shown below, the data corresponding to all columns except the Watson K-factor has been selected, and the column names defined.
Tutorial Section 27
Click Next to continue. Step 5: Review table definition and edit data Step 5 can be used to review the table selections and edit values in the table before going on to select the units for the columns. The table can be inverted by clicking the right mouse button on the table and selecting Invert table from the pop-up menu that appears. The component table now appears as follows:
28 Tutorial Section
Step 6: Choose units of table columns In this step, the units used in the source table need to be identified. A base unit system is defined first. Units can then be set for individual columns as required by right-clicking on the column header and selecting the unit for that column from the pop-up menu. The units corresponding to the critical properties for this example have been selected as shown below.
It is important to note that selection of units in this step should correspond to the units used in the original file from which the table is being imported. No unit conversion is done at this stage. At this point, the table import may be completed by clicking on the Finish button. Any conversions to the current WinProp unit system will be performed and the data will be entered into the WinProp table. To view the table with quantities converted to different units or to save the table to a file, check on the box labeled Apply unit conversion and click Next to continue. Step 7: Choose units for table columns to convert data to In this step, the user has a choice of viewing the table with different units applied. Note that changing the units in this step does not affect what units will be used to display the data in WinProp. The table can also be saved to a separate file by clicking on the button labeled Save converted table to NEW file. In this example, the table from the previous step is shown after conversion to field units.
Tutorial Section 29
Click Finish to exit Table Import Wizard and complete the import of data into WinProp.
30 Tutorial Section
Overview
This form contains the structure of the data set. This is the first form presented to the user when WinProp is invoked. The column of the table labeled Forms contains the title for each calculation form included in the data set. By default the required forms Titles/EOS/Units, and Component Selection/Properties are pre-selected and cannot be removed. The Composition form is also required following these forms, thus it is included by default as well. The data entry form corresponding to a given row can be activated by double clicking on that row. Data can be entered and edited on each form. To insert a calculation option: (1) select the row where the new calculation will be inserted by clicking on that row; (2) select a calculation option from the menu or by clicking one of the buttons on the calculation option toolbar. The Inc (Included) column indicates whether or not a calculation option will be executed when the data set is run. A checkmark in this column indicates that the option will be included, while an X-mark indicates that the calculation will be excluded. Calculations can be included/excluded by right-clicking on the desired row and selecting Include Calculation or Exclude Calculation from the pop-up menu.
A U in the Stat (Status) column indicates that the data for the corresponding option are undefined. Once data for a particular form are entered as described above, the U will be cleared from the status column. The text in the Comments column comes from the Comments text box on each form. These comments are also printed in the output file for each calculation option.
Copy Paste
You can use the Copy and Paste option to transfer information and calculation options within one WinProp data set or from one data set to another.
Titles/EOS/Units Selection
Overview
This form is pre-selected by WinProp and appears as the first form in all WinProp data files. It is used for documenting the run, selecting the unit system and for choosing the equation of state (EOS) to be used for all calculations included in the data file.
Data Input
Comments
Enter your comments regarding this data set. These comments will be shown in the Data set structure form.
Titles/EOS/Units Selection 33
Equation of State
Selection of the equation of state for the oil and gas phases. The default is PR (1978). PR(1978) PR(1976) SRK(G&D) SRK Peng-Robinson equation of state with 1978 expression for constant "a". Peng-Robinson equation of state with 1976 expression for constant "a". This is the original equation of state. Soave-Redlich-Kwong equation of state with the constant "a" proposed by Graboski and Daubert[6]. Original Soave-Redlich-Kwong equation of state.
Units
psia & deg F kPa & deg C kg/cm2 & deg C Pressures in psia and temperatures in F. Pressures in kPa and temperatures in C. Pressures in kg/cm2 and temperatures in C.
Feed
Mole Mass The feed on Form Composition is in moles, mole fractions, or mole percent. The feed on Form Composition is in mass (e.g. kg), mass fractions, or mass percent.
When the Mass option is selected, WinProp converts all mass fractions to mole fractions using the component molecular weights. All outputs will contain the corresponding mole fractions and not the input mass fractions.
34 Titles/EOS/Units Selection
Components
Library Components
To choose library components, select Options|Insert library components from the menu. The following form will be activated:
Components 35
Select components from the list by clicking on them with the left mouse button. Use the <Shift> and <Control> keys for multiple selections. Pure hydrocarbon components, light gases and water may be selected from the library, as well as generalized single carbon number (SCN) petroleum fractions FC6 through FC45. The specific gravities, molecular weights and boiling points of the SCN fractions are taken from Whitson (1983). The critical properties of these fractions are calculated with the Lee-Kesler correlations (Kesler and Lee, (1976)). The component molecular weights are shown in brackets for each component primarily to allow the user to select generalized SCN fractions to approximate a heavy end of known molecular weight. The order in which components are selected depends on the sequence of mouse clicks. Click on View selection order to view this order. The component order is important for lumping into pseudo-components, as only components that are adjacent to one another can be lumped together.
The critical pressure, critical temperature, acentric factor and molecular weight are required input. Values will be estimated for any of the OPTIONAL DATA parameter fields that are left blank. Critical compressibility is used only to calculate critical volume. Critical volume is used in the calculation of binary interaction parameters (see the section on Interaction Coefficients below). Specific gravity and boiling point temperature are used to estimate ideal gas enthalpy coefficients. Specific gravity is also used along with the critical properties to estimate Racketts compressibility factor, which is employed in calculating temperature dependent volume shifts.
36 Components
A minimum of two of the three properties must be entered. If one of the properties is not entered, it will be estimated using the selected Physical Properties Correlation. Note that critical properties are calculated from specific gravity and normal boiling point; molecular weight is used for determination of mass densities only. Thus if you enter SG and Tb, the critical properties will be unaffected by the choice of Physical Properties Correlation. The stated ranges of accuracy for the correlations are as follows. Twu: Tb up to 715 C and SG up to 1.436 (Twu, 1984). Goossens: MW from 76 to 1685 (C120), Density from 0.63 to 1.08 g/cc and Tb from 33 to 740 C (Goossens, 1996). Riazi-Daubert: Tb up to 455 C and MW from 70 to 300 (Riazi and Daubert, 1980). For petroleum fractions up to about C20, all three correlations give similar results. For heavier fractions, the Riazi-Daubert correlation shows larger errors than the other two. The Goossens correlation gives very good predictions of MW from the other properties for alkanes up to C120. It should be noted that the form of this correlation limits boiling points to a maximum of 805 C, regardless of the molecular weight and specific gravity. Once the physical properties are known, the critical constants for the component are determined using the selected Critical Properties Correlation. The ranges of applicability of the Twu and Riazi-Daubert correlations are as given above. The Lee-Kesler correlation was developed for Tb up to 650 C, but is internally consistent for extrapolation above this temperature (Kesler and Lee, 1976). For acentric factors, the Lee-Kesler correlation is recommended for petroleum fractions.
User's Guide WinProp Components 37
Component Properties
After components have been selected or defined, their parameters and properties are shown on the form Component Selection/Properties. A typical example is illustrated below.
This form contains several tabs. The properties shown on Tab Component are listed in the table below. Additional explanation regarding some of the parameters is given in the notes following the table. Use of the temperature dependent volume shift feature is described under Racketts compressibility factor in the notes. Heading Component HC Pc(atm) Tc (K) Acentric fact. Mol. weight Vol. shift Z (Rackett) Vc (l/mol) Vc (viscosity) Omega A Omega B SG
38 Components
Parameter or property Component name (maximum 8 characters) Hydrocarbon flag (=1 for hydrocarbons) Critical pressure in atm Critical temperature in K Acentric factor Molecular weight Volume translation (dimensionless) Racketts compressibility factor Critical volume in l/mol Critical volume in l/mol for viscosity calculations a EOS parameter b EOS parameter Specific gravity (water = 1)
User's Guide WinProp
Tb (deg F | deg C) Parachor Ref. Henry (atm) V inf. (l/mol) P ref. (atm) Enth. Coeff. A Enth. Coeff. B Enth. Coeff. C Enth. Coeff. D Enth. Coeff. E Enth. Coeff. F Heating Value
Normal boiling point in F (field units) or C (SI units) Parachor IFT parameter Reference Henrys constant in atm Molar volume at infinite dilution Reference pressure for Henrys constant in atm Ideal gas enthalpy coefficient A (for units see note below) Ideal gas enthalpy coefficient B (for units see note below) Ideal gas enthalpy coefficient C (for units see note below) Ideal gas enthalpy coefficient D (for units see note below) Ideal gas enthalpy coefficient E (for units see note below) Ideal gas enthalpy coefficient F (for units see note below) Heating value (for units see note below)
Notes on Component Properties Hydrocarbon (HC) Flag: Binary interaction parameters between components with HC flags
set to 1 are calculated via a correlation as described in the section on Interaction coefficients below. The interaction parameters between all other pairs of components may be set individually. Thus, if you wish to set individual interaction parameters between one component and all others, change the value of the HC flag for that component to 0. Note that the HC flags for CO2 and H2S have special values and should not be changed.
Volume Shift: The volume translation technique of Peneloux et al. (1982) is available for
improving the prediction of phase density with the equation of state. Volume shift parameters are set to zero by default. The correlation of Jhaveri and Youngren (1988) can be applied to calculate volume shift parameters for all components by selecting VolumeShift|Reset to correlation values from the menu. To remove volume translation for all components select VolumeShift|Reset to zeros. Temperature dependent volume shifts can also be used by selecting the check box above the component table. The calculation of temperature dependent volume shifts is described next under Racketts compressibility factor. When printing component properties to the output file or for export to the GEM simulator, the most recently used volume shift values will be output.
Racketts compressibility factors are available for all library components. For pseudocomponents, Racketts compressibility factors are back calculated from the critical properties and specific gravity using the assumption that the specific gravity is approximately equal to the saturated liquid density at 60 F.
Critical Volume: Critical volumes are used only in the calculation of hydrocarbonhydrocarbon binary interaction parameters as described below under Interaction coefficients.
Components 39
Critical Volume for Viscosity: Critical volumes are used in the Jossi, Stiel and Thodos viscosity correlation (Reid et al., 1977) as described in this chapter under Viscosity parameters. These critical volume values are used only for the calculation of viscosity, and thus may be modified via regression to match experimental viscosity data without affecting the calculation of any other properties. Omega A and Omega B: The default values for a and b for the Peng-Robinson
equation of state are 0.45723553 and 0.077796074 respectively. For the Soave-Redlich-Kwong equation of state, these values are 0.4274802 and 0.08664035 respectively.
Specific Gravity and Normal Boiling Point: Specific gravity is defined as the
liquid density of the component at 60 F and 1 atm divided by the density of water at 60 F and 1 atm. For components with normal boiling points below 60 F, the liquid density is taken as the saturated liquid density at 60 F. If SG and Tb have been used to calculate critical properties and acentric factors, changing SG and Tb in the table will not affect the other properties. If you wish to recalculate the properties of a particular component with revised values for SG and Tb, please delete that component from the table using Options|Delete component, and insert a new component with revised values for SG and Tb, using Options|Insert own component|SG, TB and MW.
Parachor: The parachor value is used for calculating interfacial tension. Parachors are
available for all of the library components. For pseudo-components and user components, parachors are estimated based on molecular weight using a correlation proposed by Firoozabadi et al. (1988).
Reference Henrys Constant, Molar Volume at Infinite Dilution and Reference Pressure: These properties are used in calculating the solubility of
components in the aqueous phase. There are three methods available for specifying these parameters: (1) Entering nonzero values for these properties in the component table, (2) entering zero values in the component table to allow internal estimation of Henrys constants, (3) entering zero values in the table, but overriding the internal Henrys constants with user input values entered for individual flash calculations. If nonzero values for the solubility parameters are entered in the component table, Henrys constants are calculated from:
ln H i = ln H io + i (p p io ) / RT where the superscript o refers to the reference condition. If experimental solubility data is to be matched using regression, this method for defining the solubility parameters must be used. Correlation values can be entered in the table by selecting Aqueous Solubility| Calculate component solubility parameters from the menu. Methods 2) or 3) will be used if the solubility parameters are all set to zero. This can be done by selecting Aqueous Solubility|Reset solubility parameters to zero from the menu. If the reference solubility parameters are set to zero in the component table, Henrys constants will be estimated internally for all components for each Oil-Gas-Water flash. Method 2) may be overridden by specifying component Henrys constants for individual OilGas-Water flash calculations.
40 Components
H ideal = H A + H B * T + H C * T 2 + H D * T 3 + H E * T 4 + H F * T 5 where the temperature T is in R. The ideal enthalpy coefficients HA through HF should be specified in units to give Hideal in Btu/lb.
Component Heating Values: The heating value of a component is the heat of combustion assuming the reaction goes to completion i.e. the reaction takes place with excess oxygen and the final products are carbon dioxide and water. In SI system the units are kcal/gmol and in Field units are Btu/gmol.
Approximate values have been assigned to the Library components. These values were taken from the CRC Handbook of Chemistry and Physics, 65th edition, CRC Press Inc, 1984, pages D275-D280 (see table below). WinProp will write out the HEATING_VALUES keyword and the associated values to the .gem output file. This file can then be referenced by a GEM data file using an include statement or the contents of the .gem file can be copied and pasted at the appropriate location in the GEM data file. Currently for pseudo components created by WinProps splitting and or lumping options, no method has been coded for estimating the heating value; accordingly for pseudo components values of zero are assigned. However heating values for pseudo components can be estimated based on the values assigned to the library components given the actual composition of the pseudo component is known. Once these values are estimated simply edit the values in the last column of WinProps component properties form and save the form. For example for pseudo component c2-c3 assuming a split of 50% c2 and 50% c3 and using the built in values in WinProp the heating value is calculated by mole fraction averaging as: 0.5*1478.46+0.5*2105.16 = 1791.81 Btu/gmol. Values for other pseudo components such as c4-c6 can be estimated in a similar manner. For the plus fraction such as C10+ if the breakdown of the carbon number vs. mole fraction is known then mole fraction averaging can be applied. If the distribution is not known then assign the value corresponding to the presumed largest mole fraction carbon number, for example for C10+ this might be C12. The heating value for the library component FC12 of 7722.09 Btu/gmol would then be assigned to C10+. GEM will calculate and report the heating value of all the well streams in the output file using the known composition of the stream by mole fraction averaging the entered component heating values supplied by the user. Once the HEATING_VALUES keyword appears in a GEM data file a heating value for the separator gas stream for wells and groups will be calculated and be available for plotting with RESULTS. The heating value assigned to the library components in WinProp are shown below. For the carbon fraction FC7-FC45 the heating value equals 1002.57 kcal/gmol + 157.44 kcal/gmol increment for every carbon number greater than 6. Same values are used for NC6 and FC6 and NC7 and FC7 etc. For pseudo components values of zero will be assigned, as at present there is no method implemented for estimating these values.
Components 41
Component Name H2S N2 CO2 CH4 (or C1) C2H6 (or C2) C3H8 (or C3) IC4 NC4 IC5 NC5 FC6 FC7 FC8 FC9 FC10 FC11 FC12 FC13 FC14 FC15 FC16 FC17 FC18 FC19 FC20 FC21 FC22 FC23 FC24 FC25 FC26 FC27 FC28 FC29 FC30 FC31 FC32 FC33
Heating Value (Btu/gmol) 0.0 0.0 0.0 844.29 1478.46 2105.16 2711.54 2711.54 3353.66 3353.66 3975.91 4600.28 5224.64 5849.00 6473.36 7097.73 7722.09 8346.45 8970.82 9595.18 10219.54 10843.91 11468.22 12092.63 12717.00 13341.36 13965.72 14590.08 15214.45 15838.81 16463.17 17087.54 17711.90 18336.26 18960.63 19584.99 20209.35 20833.71
42 Components
FC34 FC35 FC36 FC37 FC38 FC39 FC40 FC41 FC42 FC43 FC44 FC45 NC6 NC7 NC8 NC9 NC10 NC16 TOLUENE BENZENE CYCLO-C6 H2O
21458.08 22082.44 22706.80 23331.17 23955.53 24579.89 25204.26 25828.62 26452.98 27077.35 27701.71 28326.07 3975.91 4600.28 5224.64 5849.00 6473.36 10219.54 3705.97 3097.15 3715.32 0.0
Example: Consider an 8-components fluid, with the last three components being pseudo components. In Field units, the heating values as written out by WinProp would result in the following lines appearing in the .gem output file:
*NC 8 3 *COMPNAME 'CH4' 'C2H6' 'C3H8' 'NC4' 'NC5' 'FRAC1' 'FRAC2' 'FRAC3' *HEATING_VALUES 844.29 1478.46 2105.16 2711.54 3353.66 0.0 0.0 0.0
Interaction Coefficients
Interaction coefficients (ij) are introduced to account for the molecular interaction between dissimilar molecules. Their values are generally obtained by fitting the predicted saturation pressures to experimental data. Interaction coefficients for component pairs are shown on Tab Int. Coef.. An example is shown below.
Components 43
where vci is the critical volume of component i, and is the hydrocarbon hydrocarbon interaction coefficient exponent. It has been shown that a value of 1.2 provides a good match of the paraffin paraffin interaction coefficients of Oellrich et al (1981). However, it is recommended that this value be obtained by matching experimental data (e.g. saturation pressure data). To avoid cluttering the table of interaction coefficients, the HC interaction coefficients are not shown when the form is loaded. To view them, click on Show HC Int. Coef. button. To hide them, click on Hide HC Int. Coef. button. With this version of WinProp, it is possible to define multiple HC:HC interaction coefficient groups, each with its own value of the exponent. HC:HC groups can also be selected as independent parameters in regression, please see the chapter on Regression. The list of groups currently defined is shown in the list box with the caption HC Int. Coef. Exp.. The entries include a name and in brackets the value of the exponent. To see the group ID for all HC-HC pairs on the interaction coefficient table, click on the Show HC-HC Group(s) on grid button.
44 Components
The value of the exponent for a given group(s) can be changed by invoking a custom form designed to handle the tasks associated with managing these groups. This form is invoked by clicking the button on the Int. Coef. tab with the caption HC:HC Groups / Apply value to multiple non HC-HC pairs. This form is shown below.
The currently selected group is shown under the Name label. The list of pairs that belong to this group is shown in the list box labeled Selected pairs. The user can scroll through all defined groups in the drop down list box under the Name label. The full list of pairs that do not currently belong to any group can be seen on the list box under the Select pairs frame. These pairs can be assigned to any defined group(s). If any orphans remain when this form is saved then these are assigned to the default group, i.e. group # 1. Initially only a single group is created with the exponent value of 1.2. The value of the exponent can be changed via the text box with the label Exponent value. All HC:HC pairs initially belong to this group. To create a new group first select the HC:HC option button under Type and then click on the Create New button. This new group will be assigned the name HcIntCoefExp-2 with a value of 1.2 for the exponent. For pairs to be assigned to this new group # 2, group #1 must first relinquish these. This is done by first selecting group # 1 from the group list, identifying the pairs that will be removed (by pressing the left mouse button while holding the CTRL key down) from the Selected pairs list box and then clicking on the Delete selection(s) button. These pairs will be removed from group # 1 as reflected in the revised list in the Selected pairs box. To pick these pairs up for group # 2, change the name to group # 2, select pairs by highlighting and then pressing the Apply selection(s) button. At least one pair must be assigned to each group and a given pair can be assigned to a single group only. To delete a group click on the Delete Group button.
User's Guide WinProp Components 45
Viscosity Parameters
There are two types of viscosity correlation available in WinProp: the Jossi, Stiel and Thodos (JST) correlation as described in Reid et al. (1977), and the Pedersen corresponding states correlation as presented in Pedersen et al. (1984) and Pedersen and Fredenslund (1987). The viscosities of liquid and vapor phases are calculated with the same correlation. The choice of correlation is made on the Viscosity tab of the Component Selection/Properties form by selecting one of the option buttons under Viscosity Model Type.
Jossi-Stiel-Thodos Correlation
An example of the data entry form for the JST correlation is shown below.
46 Components
The JST correlation determines the mixture viscosity from the low-pressure mixture viscosity according to the following function:
[ ( ) + 10 ]
*
4 0.25
3 4 = a 0 + a 1 r + a 2 2 r + a 3 r + a 4 r
Where M r
= = = =
Oil or gas viscosity in cP or MPas Low-pressure viscosity in cP or MPas Group Tc1/6 M-1/2 Pc-2/3 where Tc is in K and Pc is in atm molecular weight Reduced molar density, /c = vc/v
Two options are available for calculating the low-pressure mixture viscosity. The YoonThodos + Herning-Zipperer method computes low pressure component viscosities according to a formula developed by Yoon and Thodos and then computes the mixture viscosity according to the mixing rule of Herning and Zipperer. Both of these formulas are reported in Reid et al. (1977). The Lee-Eakin method calculates the low-pressure mixture viscosity directly using a correlation based on the molecular weight of the mixture presented by Lee and Eakin (1964). The value of is calculated by first obtaining mole fraction weighted average values for the mixture critical temperature, pressure and molecular weight. The mixture critical volume vc is calculated from:
nc v c = x i v ci i =1
1/
Where is the mixing exponent parameter, xi is the composition and vci is the critical volume for viscosity calculation (vc(viscosity) on Tab Component). , a0, a1, a2, a3, and a4 are entered on Tab Viscosity. Default values are shown when the form is first activated. As well as the correlation coefficients (, ai) and critical volumes for viscosity (and to a lesser extent, the critical temperatures and pressures), the JST method depends very strongly on the density of the mixture predicted by the equation of state. Thus, use of the JST correlation may result in large errors if the phase densities are incorrect. It is recommended that the EOS be tuned to match volumetric data before attempting to predict or match viscosities with the JST correlation.
Pedersen Correlation
The Pedersen viscosity correlation uses the principle of corresponding states to calculate the viscosity of a component or mixture, knowing the viscosity of a reference substance at the same conditions of reduced pressure and temperature. The deviation from simple corresponding states is accounted for by a rotational coupling coefficient, . The viscosity of the mixture is calculated according to the following formula:
mix ( P, T ) Tc,mix = o (Po , To ) Tc,o
User's Guide WinProp
1 / 6
Pc,mix P c ,o
2/3
MWmix MW o
1/ 2
mix o
Components 47
Where Tc Pc MW
= = = = =
Viscosity Critical temperature Critical pressure Molecular weight Rotational coupling coefficient
The subscript mix refers to the mixture property, and the subscript o refers to the reference substance property. The reference substance for the Pedersen model is methane. The mixture critical temperature and pressure are calculated using mixing rules that are a function of the component critical temperatures and pressures and mole fractions. The molecular weight of the mixture is determined from:
b2 b2 MWmix = b1 MWw MWn + MWn
where MWw is the weight fraction averaged molecular weight, and MWn is the mole fraction averaged molecular weight. The rotational coupling coefficient is calculated as follows:
b5 4 = 1 + b 3 b r MW
where r is the reduced density of the reference substance. The viscosity of a mixture calculated using the Pedersen model depends strongly on the critical pressures, critical temperatures and molecular weights of the components, and the coefficients bi shown in the above two equations. Two different versions of the Pedersen correlation may be chosen. The one labeled Modified Pedersen (1987) uses a modification to the methane viscosity equation as described in Pedersen and Fredenslund (1987). This modification showed improved results for mixture viscosities up to approximately 10 cP. Each modification has a set of default coefficients. These coefficients may be modified during regression to match experimental viscosity data.
Aqueous Phase
The Aqueous phase tab is used for setting properties of the water phase for use in multiphase Oil-Gas-Water calculations. The form is shown below.
48 Components
supported for the second set. The user can edit the values of these properties from the default assignments. The user can also reset back to the original values by selecting Set Selection|Reset 2nd to 1st. The second set parameters can also be used in regression. To use a second set parameter in regression the user does not have to enable the second set component properties first. The second set parameters can be selected directly on the Regression Parameters form in a manner similar to first set properties. The initial value of the property will be set equal to the corresponding first set parameter. The second EOS parameter set, when enabled, is used in performing the following calculations: separator, separator calculation associated with the constant volume depletion experiment (to determine yields at surface) and in differential liberation experiment when flashing the residual oil (at atmospheric pressure and reservoir temperature) to standard conditions (atmospheric pressure and temperature).
50 Components
In the Interaction Coefficient Table frame, the format of the table can be selected as either upper or lower triangular form. By default, the aqueous phase solubility parameters are not printed with the other component properties. To turn on this option, select the check box in the Solubility Parameters frame. If an Oil-Gas-Water flash is included in the data set before the print options form, the Henrys constants and molar volumes at infinite dilution used in the flash will be available for printing. Optionally, the parameters may be recalculated at a specified pressure and temperature before printing.
Components 51
Overview
This chapter describes the common data required for most calculations. These include Composition specification, Initial K-values, Output level, and Stability test level. Generally, the built in default values are used in the calculations. The saturation pressure calculation, which is common to most laboratory experiment simulation options, is discussed in the next chapter.
Composition Specification
Compositions are entered in moles or in weight units, specified as fraction or percent. Values are normalized internally. If weight fractions or percents are entered, they are converted internally to mole fractions. To use weight units, select the appropriate option on form Titles/EOS/Units. The table on form Composition contains two columns for composition input. The primary composition corresponds generally to the composition of the oil or gas in place. Values must be entered for the primary composition. The secondary composition corresponds normally to the injected fluid. The secondary composition need not be entered and will default to zero. An example of form Composition is shown below.
Several composition sections can be defined in a data set. All calculations following a composition section will use the composition of that section until the end of the run or another composition section is encountered. In the following example, the fluid composition from Well 16 is used for a series of calculations. Similar calculations are then performed with the fluid composition of Well 20.
The feed composition used for all calculation options can be a mixture of the primary composition and the secondary composition the feed from the previous calculation option
the vapor composition from the previous calculation option the liquid composition from the previous calculation option the composition from Phase n from the previous calculation option
The feed composition is specified from the Combo Box Feed, located on the last tab of most calculation options. The selection of the feed composition for a two-phase saturation pressure calculation is shown above. In this example, the composition that enters into the two-phase calculations is a mixture containing 80 mole % of the primary composition and 20 mole % of the secondary composition. When Phase is selected, you enter the Phase Number in the adjacent text box. Some calculations accept only the Mixed and Previous option. The Combo Box Feed displays only these items in this case.
Initial K-Values
Initial K-values are required to start most calculations. These can be estimated internally from Wilsons equation (Internal), i.e.
ln K i =5.37 (1 + i ) (1 Tci / T )+ln ( p ci / p)
from a previous two-phase calculation (Previous) from Phase n of a previous multiphase calculation (Phase)
When Phase is selected, the Phase Number is entered in the adjacent text box.
Output Level
The Output level for a normal run is 1. If more information is required, for example the results of each iteration of a flash calculation, select an Output level value of 2.
Overview
This chapter describes calculations for mixtures on the phase boundaries: Bubble point and dew point calculations Phase boundary diagram construction (pressure-temperature, pressure-composition, temperature-composition and pseudo-ternary) Critical-point calculation Multiple-contact calculation
The phase boundary calculations can also generate lines of constant phase mole fraction or lines of constant volume fraction (quality lines).
Saturation Pressure
This option is invoked by selecting Calculations|Saturation Pressure. An example data set for this option is sat-pressure.dat. For data entry corresponding to items on tab 2, that is Feed, K-values, Output level and Stability test level specifications, see the Chapter Common Data Required for all Options. A value of the temperature at which the saturation pressure is to be calculated is required. Enter a value in the text box labelled Temperature. An estimate of the saturation pressure is also required; enter a value in the text box labelled Saturation Pressure Estimate. If this is a poor estimate, ask WinProp to generate internally a better initial guess for saturation pressure calculation by checking the box Improve saturation pressure estimate. Details of the calculation techniques can be found in Nghiem et al. (1985). Finally at a given temperature there are two saturation pressures, the upper and lower values respectively. The upper value can be a dew point or bubble point fluid, the lower is a dew point fluid. By default the upper value is calculated as this corresponds to the reservoir saturation pressure at the given temperature. The lower value can be chosen instead by selecting the button Lower dew point in the frame labelled Calculation option. Experimental data related to a saturation pressure calculation that can be matched via regression are shown on the table on the first tab, Calculations. These include saturation pressure, liquid and vapor mass densities, compressibilities and viscosities. The weight assigned to each experimental data value can also be specified.
User's Guide WinProp Two-Phase Saturation and Phase Boundary Calculations 57
Saturation Temperature
This option is invoked by selecting Calculations Saturation Temperature. An example data set for this option is sat-temperature.dat. For items on tab 2, Feed, K-values, Output level and Stability test level specifications, see the Chapter Common Data Required for Options. A value for the pressure at which the saturation temperature is to be calculated is required. Enter a value in the text box labelled Pressure. An estimate of the saturation temperature is also required; enter a value in the text box labelled Saturation Temperature Estimate. If this is a poor estimate, ask WinProp to generate internally a better initial guess for saturation temperature calculation by checking the box Improve saturation temperature estimate. Generally there are two possible values for the saturation temperature at a given pressure. The larger value corresponds to a dew point fluid whereas the lower value corresponds to a bubble point fluid. By default the larger value is calculated. The lower value is chosen by clicking on the button Lower sat. temperature in the frame labelled Common options. Details of the calculation techniques can be found in Nghiem et al. (1985). Experimental data related to a temperature pressure calculation that can be matched via regression are shown on the table provided on tab Calculations. These include saturation temperature, liquid and vapor mass densities, compressibilities and viscosities. The weight assigned to each experimental data value can also be specified.
In the process of constructing the envelope, WinProp also calculates the location of critical points through interpolation. This is a very efficient method for estimating critical points if they exist on the portion of the phase envelope being constructed. A direct method of calculating critical points is also available (see the section on Critical point calculation). A typical PT diagram is shown below:
Gas condensate Phase Envelope Pressure-Temperature Diagram
14,000
12,000
8,000
2-Phase boundary 99.000 volume % 90.000 volume % 75.000 volume % 60.000 volume % 55.000 volume % 50.000 volume % 45.000 volume % 40.000 volume %
Critical 95.000 volume % 80.000 volume % 70.000 volume % Critical 55.000 volume % 50.000 volume % 45.000 volume % 35.000 volume %
6,000
4,000
2,000
0 -200
200
400
600
800
Envelope Specification
The type of envelope to be calculated is specified on tab Envelope Specification. First, select either X-Y Phase Envelope or Pseudo-Ternary Phase Envelope at the top of the tab. This selection will activate the corresponding data entry area. X-Y Phase Envelope For X-Y phase envelopes, you must select which variable to use on the X-axis (independent variable) and the Y-axis (dependent variable). The choices are Temperature and Composition for the X-axis and Pressure or Temperature for the Y-axis. For a Pressure-Temperature (P-T) diagram select Temperature as the independent variable and Pressure as the dependent variable. For a Pressure-Composition (P-x) or swelling curve select Composition as the independent variable and Pressure as the dependent variable. Finally for a Temperature-Composition (T-x) diagram select Composition as the independent variable and Temperature as the dependent variable. The envelope is generated by taking steps in terms of the independent variable, and determining the corresponding value of the dependent variable on the phase boundary. Minimum and maximum values for the X- and Y- variables are specified along with the axis definitions. The calculation stops when any of these limiting values are exceeded. When composition is selected as the independent variable, minimum and maximum independent variable step sizes are also specified, as well as the upper and lower limits for the axis. P-x and T-x diagrams are generated by adding a fluid defined by the secondary composition on the last Composition form to the fluid defined as the feed for the envelope calculation.
Two-Phase Saturation and Phase Boundary Calculations 59
For P-T diagram the value entered in the Temperature combo box is taken as the initial starting point for the calculation on the upper saturation pressure curve. Two types of curve(s) can be generated, line(s) of constant mole fraction of the vapor phase or line(s) of constant volume fraction vapor phase. The latter are also known as quality lines. These are specified on Tab 2, Envelope Construction Controls on the table in the frame labelled Quality/Mole Fraction Lines Specification. If a value of (x) is chosen for a line, then a value of (1-x) is automatically selected as well. This ensures that a starting point on the upper saturation pressure curve at the initial temperature is always selected whether there is a dew point or a bubble point. This also means that for example if x = 0.0 is selected and the upper saturation pressure is a bubble point then the program will attempt to trace from the bubble point line (x=0.0) as well as the lower dew point (for 1-x=1.0). However the chances are that the attempt to trace from the lower dew point will fail as the algorithm has difficulties starting off from very small pressures. To select only the starting point corresponding to value (x) check off the box labelled Select value from the above table as well as one minus the value in the table. This implies the user knows the type of upper saturation pressure, dew point or bubble point. The algorithm will attempt to generate both the part corresponding to the value (x) as well as (1-x) for all starting points. For example if x = 0, is chosen then both the bubble and dew point curves will be generated. All values should be between 0 and 1. A maximum of 25 such lines can appear on a single plot. By default a single value corresponding to vapor phase mole fraction equal to 0.0 is pre-selected. If x = 1.0 is selected and both an upper and lower dew point exists, the starting point on the upper dew point will be selected. If starting points on both upper and lower dew point curves is desired then check on the box labelled Trace from all potential starting points on Tab 2. The value entered in the Pressure combo box, either a number or the selection Unknown may be used as the initial guess for saturation pressure at T = Ts if a 2 phase region cannot be found at T= Ts by scanning the interval from Pmax to Pmin. For the majority of cases a value is not required for the Pressure. When composition is selected as the independent variable, both pressure and temperature must be entered, although the value corresponding to the dependent variable will be determined internally. In the unlikely scenario that this cannot be done the value entered for the dependent variable will be used as an initial guess in the saturation calculation. The initial composition is taken as that defined by the Feed specification for the envelope calculation. The values entered for Mole fraction vapor (Fv) or Volume fraction vapor (Vv) are used to define which lines on the phase envelope are generated. If a critical point is encountered, the line corresponding to (1- Fv) will also be calculated. For example, with Fv=1, the entire phase boundary (starting on the dew point side) will be calculated. If a value is specified for volume fraction vapor, the quality line corresponding to Vv will be calculated. Again, if a critical point is encountered, the line corresponding to (1-Vv) will also be calculated. To calculate phase boundaries, select Fv = 0.0 and/or 1.0 or Vv = 0.0 or 1.0. When tracing lines of constant volume fraction, an additional stopping constraint can be placed on the calculation by specifying minimum and maximum allowed values of vapor mole fraction. By default these values are set to 10 and +10 respectively, thus the calculation will not halt unless large nonphysical values of the vapor mole fraction are calculated.
Pseudo-Ternary Phase Envelope The first step in generating the pseudo-ternary phase envelope is specification of the pseudocomponents. When the Pseudo-Ternary option is selected, a grid is displayed listing all of the components. The primary and secondary compositions are shown to assist the user in defining the pseudo-components. Components are assigned to pseudo-components by entering the number 1, 2 or 3 in the column of the table labeled Pseudo. Pseudo-component 1 is at the lower left corner of the triangle, 2 is at the lower right, and 3 is at the top. The diagram is generated by locating the point on the diagram corresponding to the specified mole or volume fraction vapor for the feed composition. The composition of the phase in equilibrium with this phase is obtained from the K-values. A step in the construction is taken by adding fluid with the secondary composition, and the next point is calculated with this new composition. Note that different pseudoization schemes will result in different envelopes being generated. As for the X-Y diagram, minimum and maximum values for the mole fraction of secondary fluid can be specified, as well as minimum and maximum secondary fluid step sizes. Pressure and temperature must be specified, as they are fixed for the ternary diagram. Mole fraction vapor, volume fraction vapor, minimum mole fraction vapor and maximum mole fraction vapor may be specified as discussed under X-Y Phase Envelopes.
Cricondenbar/Cricondentherm Calculation
The cricondenbar corresponds to maximum pressure on the PT phase envelope whereas the cricondentherm corresponds to the maximum temperature. These are estimated in a twophase PT envelope construction (see Phase boundary and quality line calculations) or can be calculated directly by selecting Calculations|Cricondenbar/-therm. An example data set for this option is cricon.dat. For Feed, K-values, Output level and Stability test level specifications, see the Chapter Common Data Required for all Options. As initial guesses for pressure and temperature, you can specify Unknown or Previous (value from the previous calculation option), or type in the value of the initial guess.
Flash Calculations
Overview
Flash calculations determine the split of a system at a given pressure, temperature and feed composition. The number of phases and the properties for each phase are calculated. WinProp can perform many types of flash calculations: 1. Two-phase vapor-liquid 2. Three-phase vapor-liquid_1-liquid_2 3. Three-phase vapor-liquid-aqueous 4. Four phase flash calculation (fluid phases only) 5. Multiphase flash calculations with a solid phase 6. Isenthalpic flash calculation In the above calculations, the fluid phases are modeled with an EOS, except for Calculation No. 3 where the component solubility in the aqueous phase is modeled by Henry's law. Calculation No. 5 can be used for modelling asphaltene and wax precipitation. Flash calculations performed in the single-phase region will yield a single-phase system. An option for singlephase calculation is also available in WinProp and is described in this chapter. Common input for two-phase flash, multiphase flash and asphaltene/wax modelling calculations is described below, followed by descriptions of each of the flash types.
Common Input for Two-Phase Flash, Multiphase Flash and Asphaltene/Wax Modelling Calculations
For Feed, K-values, Output level and Stability test level specifications, see the Chapter Common data required for all options. Flash calculations are performed at the pressure and temperature specified in the Text Boxes labeled Pressure and Temperature. You can perform a series of calculations by specifying the Pressure Steps, Temperature Steps, or Mole Fraction Steps with the associated number of steps. The steps can be positive or negative. Step No. 1 corresponds to a calculation at the specified pressure and temperature or mole fraction. Specifying steps for the primary mole fraction allows calculations for a number of mixtures of the primary and secondary fluids.
Flash Calculations 63
When a series of flash calculations have been specified by setting temperature, pressure or mole fraction steps, plots of the phase properties can be generated. Specification of the phase properties (maximum of three) to plot is done on tab Plot Control. When plotting is activated, steps can be specified in one or two of the variables: pressure, temperature and mole fraction. If steps are specified for only one variable, the plots are generated with that variable as the independent variable, and the phase property as the dependent variable. Up to 100 steps in the independent variable are allowed. When steps are specified for two variables, one variable is treated as a parameter variable, and curves of the phase property are displayed for each value of the parameter variable. Up to 8 steps in the parameter variable are allowed. If mole fraction steps are specified, mole fraction is always used as the independent variable. If pressure and temperature steps are both specified, pressure is used as the independent variable.
The Oil-Gas-Water (OGW) calculation involve a three-phase calculation where the vapor and liquid phases are modeled with an EOS while the aqueous phase is modeled with Henry' law. An example data set is flash-ogw.dat. As the EOS was developed for gas-like hydrocarbon systems, it may not model accurately the aqueous phase. Li and Nghiem (1986) recommended the use of Henry's law constants for component solubility in the aqueous phase. The fugacity coefficient of Component i in the aqueous phase iw is given by
lniw = ln( H i / p)
where Hi is Henry's law constant of Component i. Hi for each component may be entered on tab Henry's Law. If Hi is not specified, WinProp will estimate it internally. See the Components chapter for more information on Henrys constants. Experimental data for 3-phase and OGW calculations may be entered on tab Experimental. These include mass densities, mole fractions, volume fractions, and viscosities of the different phases. When the flash type is set to OGW, experimental data for the solubility of components in the aqueous phase may be entered on the tab labeled Exp. Solubility. The units available for specifying the component solubilities are mole fraction, weight fraction, moles per mole of water, weight per weight of water, SCF per Std. bbl of water and std m3 per std m3 of water. Values must be entered in all cells in the solubility table. Enter a value of -1 in the table to exclude that data point from the regression. Please note that when regression is being performed on aqueous phase solubility parameters, all OGW flashes specified within the regression block must be at the same temperature. WinProp does not accept experimental data for 4-phase calculations.
Asphaltene/Wax Modelling
Theoretical Background
Thermodynamic Model The precipitation of asphaltene and wax phases is modelled using a multiphase flash calculation in which the fluid phases are described with an equation of state and the fugacities of components in the solid phase are predicted using the solid model described below. The solid phase can consist of one or more components. The approach for modeling asphaltene and wax precipitation is described in detail in Nghiem et al. (1993, 1996) and Kohse et al. (2000). The precipitated phase is represented as an ideal mixture of solid components. The fugacity of a precipitating component in the solid phase is:
* ln f s = ln f s
v + s R
p p tp p * p tp * T T T* 1 1 Ttp ln * T T T
H tp 1 1 C p R T T* R
Flash Calculations 65
where fs is the fugacity at pressure p and temperature T, fs* is the fugacity at pressure p* and temperature T*, vs is the solid phase molar volume of the component, Cp is the solid-liquid heat capacity difference, Htp is the heat of fusion at the triple point, ptp and Ttp are the triple point pressure and temperature, and R is the universal gas constant. For isothermal predictions, this equation can be simplified to give:
* ln f s = ln f s + v s (p p * ) / RT
Characterization of the Solid Forming Components The crucial step in modeling wax and asphaltene precipitation is the characterization of the solid forming components, both in solution and in the solid phase. It was found that by splitting the heaviest components into two components, a non-precipitating and a precipitating fraction, good quantitative match with experimental data was obtained. This has been independently verified for both wax and asphaltene precipitation problems. Irreversible Asphaltene Calculations WinProp has the capability to separate asphaltene precipitate into reversible and irreversible parts. This can be useful for simulating laboratory forward or reverse contact experiments with a series of asphaltene flash calculations. Asphaltene is described as a reversible solid (S1) and an irreversible solid (S2). The conversion of S1 to S2 is described by a simple chemical reaction:
S1 S2 K
where C1and C2 are the molar concentrations of S1 and S2 respectively. At equilibrium, the rate is zero and the following equilibrium constant can be derived:
K= k 21 C1 = k 12 C 2
The mole fraction of reversible solid relative to the total amount of solid is:
x1 = C1 K = C1 + C 2 K + 1
The procedure for simulating forward and reverse contact experiments is as follows: The first stage of the experiment can be modeled using the solid flash with the first stage oil and gas mixture. The total amount of solid precipitate will be determined from the thermodynamic model. At the completion of this calculation, the amounts of reversible and irreversible solid (x1 and x2) can be calculated from the above equations with a user-specified value of K. K = 0 indicates that all of the solid is irreversible, K = 1 gives equal amounts of reversible and irreversible solid, and K >> 1 implies that the solid is essentially all reversible.
66 Flash Calculations User's Guide WinProp
For backward contacts, the feed to the next flash calculation is defined by taking the liquid plus the reversible solid, and combining it with injection gas. The irreversible solid is removed from the system for this flash. For forward contacts, the equilibrium vapor phase with no asphaltene is combined with fresh oil. Therefore, for forward contacts, the degree of irreversibility will not affect the calculations.
Flash Calculations 67
Number of Solid Forming Components Of the Nc total components, the user may specify the last N1 as the number of solid forming components. The default is set to 1, that is only component number Nc can precipitate. Once this number is specified in the text box provided, the component number and name for all the precipitating components are shown on the first and second columns of the table on this tab. Depending on the method selected for computing the reference fugacity, columns 3-5 of this table will also be updated automatically. Reference Fugacity (ln (solid fugacity (atm))) Four options are available for specifying the reference fugacity through the Reference fugacity combo box: CALCULATE The reference fugacity at the specified pressure and temperature is set equal to the fugacity of the solid forming component after the system has converged to a single liquid phase or a two-phase vapor-liquid system. This is used for wax only. The reference fugacity at the specified pressure and temperature will be correlated with the pure component liquid fugacity at the same pressure and temperature. Use the value for the reference fugacity from a previous multiphase solid flash calculation. This selection implies that the value of the natural logarithm of the reference fugacity in units of atmospheres as well as the corresponding reference pressure and temperature will be input by the user for each precipitating component on the table provided. The user must select this option before the values can be entered in the table
LCORRELATE
If the reference fugacity specification is set to CALCULATE, solid onset pressures for the same mixture but at different temperatures may be specified in the Additional Onset Points table. Cp and Htp (optionally vs) can be calculated so the solid model will match these onset points. Additional Onset Points Solid onset pressures at different temperatures may be used to calculate parameters in the solid model for performing temperature-dependent precipitation predictions. The requirements for doing this calculation are: Two, three or four solid precipitation onset pressures at different temperatures must be known for one fluid composition. The solid phase must be modelled with a single component, as is normally done for asphaltene precipitation modelling. The pressure and temperature for one of the onset points must be entered on the Calculations tab as the pressure and temperature for the flash. This will be used as the reference condition, and will define the reference fugacity. Calculation of the other parameters will depend on the number of additional onset points entered, as described below. Normally vs is adjusted to match a known amount of solid at a given condition (bulk precipitation experiment) otherwise it will default as described under Solid-Phase Molar Volume.
68 Flash Calculations
1 additional onset point Cp is set to the user-input value or defaults to zero. Htp is calculated to match the specified onset point. 2 additional onset points Cp and Htp are calculated to match the specified onset points. 3 additional onset points Cp, Htp and vs are calculated to match the specified onset points. This is not normally done, as it is preferable to use vs to match a bulk precipitation experiment. Reference Pressure (psia | kPa | kg/cm2) This corresponds to the reference pressure for calculating reference fugacity. This pressure is required only if a reference fugacity is actually entered. If Field units is selected enter value in psia, for SI units in kPa and for modified SI units in kg/cm2. When the CALCULATE, PREVIOUS or LCORRELATE options are selected for the reference fugacity, the reference pressure is set internally by the program and need not be entered on the table. Reference Temperature (C for SI or F for field units) This corresponds to the reference temperature for calculating the reference fugacity. This temperature is required only if a reference fugacity is actually entered. When the CALCULATE, PREVIOUS or LCORRELATE options are selected for the reference fugacity, the reference temperature is set to appropriate values internally by the program and need not be entered on the table. Solid-Phase Molar Volume (l/mol) This corresponds to the component solid-phase molar volume for the calculation of the component solid-phase fugacity. If the molar volume is not specified, the following value is assigned: If the reference fugacity option is CALCULATE, the solid-phase molar volume is calculated from the EOS, unless 3 additional onset points have been specified. If the reference fugacity option is LCORRELATE then the molar volume is obtained from a correlation by Won (1986). If the reference fugacity option is PREVIOUS, the solid-phase molar volume from the previous calculation is used. If a value for the reference fugacity is entered, the solid-phase molar volume is calculated from the EOS.
Heat Capacity (cal/K/mol) This corresponds to the component solid-liquid heat capacity difference for calculation of the component solid-phase fugacity. If this quantity is not explicitly specified for each precipitating component, the following value is assigned: If the reference fugacity option is CALCULATE, the solid-liquid heat capacity difference defaults to zero, unless 2 or more additional onset points have been specified. If the reference fugacity option is LCORRELATE then the heat capacity difference is obtained from a correlation by Pedersen (1991).
Flash Calculations 69
If the reference fugacity option is PREVIOUS, the solid-liquid heat capacity difference from the previous calculation is used. If a value for the reference fugacity is entered, the solid-liquid heat capacity difference defaults to zero.
Heat of Fusion (cal/mol) This corresponds to the component heat of fusion for the calculation of the component solidphase fugacity. If this quantity is not explicitly specified for each precipitating component, the values are obtained from a correlation by Won (1986). Triple Point Pressure (psia | kPa | kg/cm2) If the triple point pressure for each precipitating component is known then these may be specified under the column heading Triple Pres. If Field units is selected enter value in psia, for SI units in kPa and for modified SI units in kg/cm2. If the triple point pressure is not known then the default is a value of zero, which is realistic for high molecular weight compounds. Triple Point Temperature (C for SI or F for field units) If the triple point temperature for each precipitating component is known then these may be specified under the column heading Triple Temp. If not known then the values are estimated from an internal correlation that was developed by Won (1986). Ratio of reverse over forward rate for conversion to irreversible solid This is the equilibrium constant K described above under Irreversible Asphaltene Calculations.
Single-Phase Calculation
A flash calculation in the single-phase region yields a single-phase system. However, if the fluid is known a priori to be single phase, its properties can be calculated directly with the single-phase calculation option. This option is invoked by selecting Calculations|Singlephase Fluid. Please be advised that WinProp will assume single-phase for all calculations even if the fluid is multiphase. An example data set for this option is singlephase.dat.
70 Flash Calculations
where Hspec is the specified molar enthalpy of the system and hij is the partial molar enthalpy of Component i in Phase j which is also obtained from an EOS. Calculation Method Identifier Two schemes for isenthalpic flash calculations are discussed below. The final scheme is a hybrid of these two schemes. Scheme 1 Scheme 1 consists of performing a series of multiphase isothermal flash calculations by adjusting the temperature to satisfy the energy equation. In other words, the temperature is varied in an outer loop, and the isothermal flash equations are solved in an inner loop. Techniques for solving the multiphase isothermal flash equations are taken from Nghiem and Li (1984) and Nghiem et al (1985). The isenthalpic flash calculations are initiated by an isothermal flash calculation at the specified feed composition z, the specified pressure p and an initial guess for temperature, T(0). A new temperature T(1) is then determined from the energy equation by assuming that the phase mole fractions, compositions and specific enthalpies are constant. With T(0) and T(1), a secant method for solving the energy equation is set up in the outer loop. As discussed later, Scheme 1 does not work for systems with a degree of freedom equal to unity, e.g. one-component two-phase system, two-component three-phase system. Scheme 2 Scheme 2 basically follows Michelsen's approach (Michelsen, 1987), but the implementation is different. This scheme is a stage wise procedure where the system is assumed to be initially single-phase, and where the number of phases is increased if necessary between iterations. Furthermore, this scheme attempts to converge the material balance equation, the energy balance equation and the equilibrium equation in a sequential manner. This method also works for systems with a degree of freedom equal to unity. Special Considerations Isenthalpic flash calculations are more complex than isothermal flash calculations because of the lack of the a priori knowledge of temperature (and phases) and because of the presence of narrow boiling mixtures. The implications of these two factors are discussed in the following. Phase Information Since temperature is not known a priori in isenthalpic flash calculations, the traditional stability analysis of the Gibb's free-energy surface (Nghiem and Li, 1984) cannot be used to determine the number of phases that actually exist at convergence. A stability analysis can only give the number of phases at the initial temperature estimate, which may not be the same as the number of phases at convergence. This leads to the appearance and disappearance of phases during the iterative process. This does not create any difficulties for Scheme 1 but could cause convergence problems for Scheme 2. Narrow-Boiling Systems Narrow-boiling systems are those where the enthalpy changes drastically for a small change in temperature during phase transition. Although many multicomponent fluids exhibit this behavior, a single-component fluid in the two-phase region and two-component fluid in the three-phase region are extreme examples of narrow-boiling mixtures.
User's Guide WinProp Flash Calculations 71
From the phase rule, the degree of freedom F of a system with nc components and np phases is F = nc+ 2 - np Thus for a single-component system in the two-phase region, F = 1. This implies that, if the pressure is fixed, the two-phase temperature is also fixed. In other words, pressure and temperature are dependent on each other in the two-phase region. The enthalpy for this system is determined by the phase split in the two-phase region. The same analysis applies to a two-component system in the three-phase region. Effect of Narrow-Boiling Systems on the Calculations Scheme 1 is not applicable to systems with a degree of freedom equal to unity (e.g. onecomponent two-phase systems, two-component three-phase systems) because it attempts to satisfy the energy equation by adjusting the temperature. For these systems, the energy equation can only be satisfied by adjusting the phase split. Otherwise, Scheme 1 works for any multicomponent systems with nc 3 even if they exhibit narrow-boiling behavior. Calculation Procedures A hybrid scheme, where five scheme-2 iterations are performed for every scheme-1 iteration, is very stable and robust. Of course, only Scheme-2 is used for one and two component systems.
72 Flash Calculations
Background
For systems that exhibit three-phase behavior, there exist conditions where one of the phase mole fractions goes to zero. Under these conditions, there are two phases in equilibrium with an infinitesimal amount of a third phase. The locus of all these conditions corresponds to a three-phase boundary. Nghiem and Li [21] describe calculation techniques for constructing the three-phase boundary; these are extensions of the two-phase boundary calculations described in a separate chapter. You can calculate the following envelopes: Pressure-Temperature (PT) diagram Pressure-Composition (PX) diagram Temperature-Composition (TX) diagram
Input Data
The three-phase boundary calculation is invoked by selecting Calculations|Three-phase Envelope. Examples of three-phase PT envelope and PX envelope are in envel_3ph-pt.dat and envel_3ph-px.dat respectively. This calculation requires good initial guesses for convergence. Therefore the pressure, temperature, and K-values must be obtained from a previous three-phase flash calculation near the boundary as in envel_3ph-pt.dat, or entered by the user as in envel_3ph-px.dat.
Similarly for the TX diagram, enter an initial guess for the temperature in the combo box labelled Temperature and a value for the pressure (fixed) in the combo box labelled Pressure. For all cases an initial guess for the mole fraction of either the vapor phase or the second (intermediate) liquid phase is also required. For the boundary corresponding to zero vapor phase, enter a value for the second liquid or intermediate phase mole fraction. For the boundary corresponding to zero second liquid phase, enter a value for the vapor phase mole fraction initial guess. If Use values from previous calculations is selected, WinProp will calculate the boundary corresponding to the phase with the lowest mole fraction (in the previous calculation) equal to zero. Defaults for the maximum and minimum values for the x- and y-variables can be overridden by entering values in the appropriate text boxes. The calculations stop when the maximum or minimum values are exceeded or when the maximum number of points has been calculated (see Envelope Construction Controls Tab). The calculations will also stop if the mole fraction of any phase falls outside the limits specified by the values in the text boxes Minimum phase mole frac and Maximum phase mole frac. The default values of 10 and 10 for the minimum and maximum are chosen such that the calculation will not stop unless large non-physical values of the phase mole fractions are encountered. The Tab Envelope Specification corresponding to envel_3ph-px.dat is shown below:
Maximum Number of Points This value corresponds to the maximum number of points calculated on the phase diagram. Initial Step Size The Initial step size controls the spacing between the calculated points on the envelope. Both positive and negative values may be used. For positive values, the diagram is traced initially in the direction of increasing x-values. For negative values, the diagram is initially traced in the direction of decreasing x-values. WinProp internally estimates the step size for subsequent points on the envelope. Average Number of Iterations This value is used to adjust the distance between two consecutive points on the diagram. The distance is increased if the actual number of iterations is less than the entered values, and is decreased in the opposite case. Independent Variable Interpolation Points These correspond to x-values for which you want calculated y-values. Because the step size in the envelope calculation is automatic, these interpolation values must be entered to force calculations at desired x-axis values.
The estimates of the K-values for the first point on the boundary can be from a previous calculation, or entered in the appropriate table as shown in the above figure.
Overview
Our experience shows that two representations of the components are normally required in the modelling of the phase behavior of reservoir fluids. In the first stage, the fluid system is represented by a large number of components (e.g. C1, C2, C3, ..., C29, C30+). Simple calculations such as saturation pressure calculations are performed on this many-component system to verify the adequacy of the EOS. We found that in most cases the EOS can predict accurately the saturation pressure with only minor adjustment to the Hydrocarbon Interaction Coefficient Exponent (HICE). See the chapter entitled Regression for more details. This many-component representation is not practical for compositional simulation because of the excessive run time and memory requirements. The second stage involves the lumping of the many-component system into fewer components (e.g. 10). Reservoir fluids typically consist of pure, well-defined components such as CO2, N2, C1, C2, etc., and many hundreds of heptanes and heavier components (C7+). The laboratory analysis of a reservoir fluid includes generally a gas chromatograph analysis of the C7+ fraction into Single Carbon Number (SCN) fractions up to C30+ for example. Characterization of the C7+ fraction as a number of pseudo-components is accomplished using WinProps Plus Fraction Splitting and Component Lumping calculation options. If a full extended analysis is available with mole fraction, MW and SG or Tb given for each SCN fraction, the SCNs may be entered as user components directly on the Component Selection/Properties form. If a complete analysis is not available, the Plus Fraction Splitting calculation is used to define a distribution function relating mole fractions to molecular weights of the C7+ fraction. Three distribution functions are available in WinProp: exponential, two-stage exponential, and gamma distribution. The implementation of the distribution functions depends on the experimental data available. If a partial extended analysis is given (e.g. only MW and mole fraction of the SCN fractions) and one of the exponential distribution types is selected, the splitting calculation does not use the distribution function. SG and Tb values for the SCN fractions are determined from correlations based on the SG and MW of the plus fraction. Subsequently, critical properties of the SCNs may be generated. After the splitting, the SCNs representing the C7+ fraction can be lumped into fewer components based on K-values estimated from Wilson's correlation using the Lee-Kesler mixing rules, (Lee and Kesler [15]).
If a partial extended analysis is given and the gamma distribution is selected, the parameter in the distribution is determined by minimization to obtain the best fit of the distribution to the experimental data. At this point, the analysis may be extended by using the distribution function to generate mole fraction and molecular weight data for SCNs beyond the last fraction in the experimental analysis. SG, Tb and critical properties of the SCNs may be generated and lumping to fewer components may be done as for the exponential distribution case. Alternatively, the gaussian quadrature technique may be used to determine MW and mole fractions of the pseudo-components from the distribution function. Correlations are then used to generate the SG, Tb and critical properties of the pseudo-components directly, rather than using mixing rules. If no extended analysis is available, i.e. only mole fraction, SG and MW of the C7+ fraction are known, the parameters in the chosen distribution function are adjusted to match the known data. The distribution function is then used to generate SCN mole fraction and MW. Once this is done, the characterization may proceed as described for the partial extended analysis cases above. Due to the larger number of adjustable parameters in the gamma distribution, the parameter must be specified if no extended analysis is available. If it is not input by the user, the program will estimate a value for this parameter. The Component Lumping calculation may be specified in a data set if the SCNs were not lumped within a splitting calculation, or to further reduce the number of components. The lumping scheme may be input by the user, or the program can generate the pseudocomponents using an internal algorithm. We recommend specifying a lumping scheme based on the K-values of the many-component system at a prevailing condition in the reservoir, e.g. the saturation condition.
Distribution Function Type Three choices are available for the distribution function for splitting the plus fraction: Exponential 2-Stage Exponential Gamma Number of Fluid Samples If the gamma distribution is chosen, up to 8 related fluid samples may be characterized simultaneously. If the exponential distributions are chosen, this text box is not enabled. First Single Carbon Number in Plus Fraction Enter the carbon number of the lightest SCN in the plus fraction (e.g. enter 6 to characterize a C6+ fluid fraction). Number of Pseudo-Components The SCNs can be used as is in subsequent calculations or lumped into pseudo-components right after the splitting procedure. The following options are available: No lumping Determined internally Input value The SCNs will be used as is. WinProp will estimate internally the number of pseudocomponents for the plus fraction. Specify the desired number of pseudo-components. Exponentially decreasing function appropriate for gas condensates and lighter fluids Approximation to the gamma function suitable for black oil type fluids Three-parameter gamma distribution suitable for all fluid types
When using the gamma distribution and gaussian quadrature without extended analysis, the number of pseudo-components cannot be estimated via correlation and will be set equal to 3. Lumping Method Log(K) lumping is available when characterizing a single sample with any of the distribution functions. Gaussian quadrature lumping may be used with the gamma distribution, and is required for characterizing multiple samples. Log(K) lumping defines pseudo-components as having equal ranges of log(K). Gaussian quadrature lumping defines pseudo-components via analytical integration of the gamma distribution. Critical Properties Correlation Three correlations are available to calculate the critical properties of the SCNs. 1. Lee-Kesler (Kesler and Lee [12]) 2. Riazi (Riazi and Daubert [34]) 3. Twu (Twu [36]) On the Distribution Tab, parameters relating to the chosen distribution are entered. Three of these properties are common to both exponential and gamma distribution types, as follows.
SCN Fraction MW Interval This corresponds to the interval in molecular weight for each single carbon number group. For the gamma distribution, if a variable MW is selected this value is ignored. The default is 14.026. Bias Parameter for SCN MW End Points This parameter is used for setting the minimum molecular weight for the plus fraction distribution. A value of 0 means that the minimum MW will be equal to the normal alkane MW of the same carbon number as the first SCN fraction in the plus fraction. A value of 1 means that the minimum MW will be equal to the normal alkane MW of one lower carbon number than the first SCN fraction in the plus fraction. The default value is 0.75. Distribution Function Cutoff This parameter is used in determining the number of pseudo-components for lumping. This calculation requires specification of a maximum SCN number. Setting the cutoff to 1.0 means that the maximum SCN number will be set equal to the last SCN number in the analysis. This often leads to over-prediction of the required number of pseudo-components. Setting the cutoff less than 1.0 indicates that the maximum SCN number will be taken as the one at which the ratio of the sum of the individual SCN mole fractions to the total plus fraction mole fraction exceeds the cutoff. The value should be less than 1. The default is 0.95. Parameters specific to the exponential distributions are: Mole Fraction of Component Preceding Plus Fraction This value is used to set the Y-Axis intercept of the two-stage exponential distribution function. For C6+ fraction characterization, this value should be set equal to the mole fraction of the C5 components, for C7+ fraction characterization, this value should be set equal to the mole fraction of the C6 components, etc. Y Axis Intercept of the Distribution Function This is usually set equal to the mole fraction of the component preceding the plus fraction (default). Parameters specific to the gamma distribution are: SCN MW Interval Type When fitting the gamma distribution to extended analysis data, the SCN fractions can have fixed or variable intervals in molecular weight. Choosing Constant sets the MW interval equal to the value entered under SCN fraction MW interval. Choosing Variable (match mole fraction) or Variable (match weight fraction) indicates that the upper MW boundary of the SCN fraction is varied until either the experimental mole fraction or the experimental weight fraction (default) of the SCN is matched. Eta Parameter (Minimum MW in Distribution) The eta () parameter specifies the minimum molecular weight in the gamma distribution. By default, it will be calculated as described under Bias parameter for SCN MW end points.
MW of Heaviest Pseudo-Component The choices for molecular weight of the heaviest pseudo-component are No Restriction, Internal Default or entering a value. Specifying No Restriction implies no upper limit in MW on the gamma distribution, and is not recommended. It leads to prediction of very high molecular weights for the heaviest pseudo-component. The default setting obtained by selecting Internal Default sets the heaviest pseudo-component MW equal to 2.5 times the MW of the plus fraction. If multiple samples are used and No Restriction is selected, it will automatically be reset to Internal Default. SG-Tb-MW Correlation When Gaussian quadrature is used with the gamma distribution, the following correlations are available for determining pseudo-component boiling point from specific gravity and molecular weight. 1. Twu (Twu [36]) 2. Goossens (Goossens [7]) 3. Riazi (Riazi and Daubert [34]) The controls available for determining gamma distribution parameters by minimization are: Residual Value The choices for residual value depend on what is selected under SCN MW interval type. The residual value setting indicates what experimental data for each SCN is used in defining the error function to be minimized. The choices are Molecular Weight, Mole Fraction and Weight Fraction. If a constant MW interval is chosen, then molecular weight is not available as a choice of residual value. Similarly, if a variable MW interval is chosen to match the mole fraction, then mole fraction is not available as a choice of residual value. The default is to vary the MW interval to match the weight fraction of the SCN, and adjust the distribution parameter to minimize the error function defined in terms of the molecular weights. Residual Type The choices for residual type are Sum of Squares, Chi Square Goodness-of-Fit Test or Sum of Scaled Squares. The default is sum of squares. For most applications, the difference in minimization results between the residual types will be small. Final SCN Fraction Data The residual calculation can be specified to include or not include the data from the final SCN fraction in the analysis. On each Sample Tab, the properties of the plus fraction are entered. The number of sample tabs appearing is set according to the Number of Fluid Samples entered on the General tab. If extended analysis data is available from a true or simulated boiling point (distillation) analysis, the data can be entered in the table on the Sample tab. In column 2 enter the mole fraction of each fraction. In column 3 enter the average molecular weight of the fraction. Note that if any extended analysis data are to be entered, mole fraction and molecular weight are required for each cut. If data is available then values for the specific gravity can be entered in column 4 and normal boiling point in C in column 5. Please note that if data for normal boiling point is
entered then data for specific gravity must also be entered. Sample data sets with extended analysis data are split-mw_analysis, split-mwsg_analysis and split-mwsgtb_analysis. Number of SCN Fractions If this entry is left blank, the value will default to the number of fractions in the analysis, or to 25 if there is no extended analysis. If the exponential distributions are used with extended analysis, and a value for number of SCN fractions is entered, it will be ignored. If the gamma distribution is used with extended analysis, and a value for number of SCN fractions is entered that is greater than the number of fractions in the analysis, the analysis will be extended using the distribution function to the specified SCN number. MW+ Molecular weight of the plus fraction must be entered in the text box unless extended analysis data is given. SG+ Specific gravity of the plus fraction must be entered in the text box unless SG data is given in the extended analysis table. Z+ Mole fraction of the plus fraction must be entered in the text box unless extended analysis data is given. If one of the exponential distribution function types is selected then the following data entry box will be available: Slope This is the slope of the exponentially decreasing curve of the distribution function. If not specified then it is determined internally based on data for a typical oil. If the gamma distribution function is selected then the following data entry box will be available: Alpha This parameter is analogous to the slope parameter used for the exponential distribution types. If >1, the distribution has a peak in mole fraction for an SCN greater than the initial SCN in the distribution. If =1, the gamma distribution reduces to an exponential distribution, and if <1 the function decreases more rapidly than an exponential distribution. In general, is larger for heavier fluids, and smaller for lighter fluids. The normal range is from 0.5 to 2.5. If extended analysis data is available and is not specified, it is determined by minimization to best fit the experimental data. If extended analysis data is not available and is not specified, an estimate is determined internally based on plus fraction SG and MW.
The Table Import Wizard can be used to append or insert extended analysis data at the currently selected row in the extended analysis table. The wizard is launched by clicking on the Table Import Wizard button located on any of the Sample tabs. Data for any of the columns appearing in the table may be imported. Note that the Table Import Wizard cannot be used to import columns of data for existing SCN fractions. The standard Windows cut, copy and paste functions can be used for this purpose.
First and Last Single Carbon Number in the Mud The first and last SCN in the mud must be entered in the text box on the Mud Info. Tab.
Mud Composition Table If the mud composition data is available, the data can be entered in the table on the Mud Info tab. In column 2 enter the mole fraction of each mud fraction. In column 3 enter the average molecular weight of that mud fraction. The Table Import Wizard button can be used to append or insert mud composition data at the currently selected row in the mud composition table. Level of Contamination This parameter can be input under each Sample tab, if available. The level of mud contamination is expressed as the weight fraction of the mud. If this parameter is available and the mud composition is also provided, a direct subtraction method will be used to numerically clean the contaminated sample. If this parameter is not available but the mud composition is provided, a combination of the skimming method and subtraction method will be used to estimate the level of contamination first, and then numerically clean the contaminated sample. If there is no information about the level of contamination and mud composition, WinProp can use the skimming method to numerically clean the contaminated sample based on the first and last SCN in the mud.
Lumping of Components
This option is invoked by selecting Characterization|Component Lumping. An example data set for this option is lumping.dat. An example interface for this option is shown below.
Two options are available to the user in specifying the lumping method: explicitly entering the lumping scheme or relying on the internal algorithm to determine the number of pseudocomponents. This algorithm is documented in Appendix B. The lumping method selection is made with the radio buttons located under the Lumping Method label. The user-defined scheme is specified in the table shown on this form. The first column shows the component name from the many-component system. For information purposes, the primary and secondary compositions are shown in the second and third column. The lumping scheme is specified by clicking the left mouse button in the fourth column. Clicking the first time on the i-th row sets the lumping of Component 1 to Component i of the many-component system into Pseudo-Component 1 of the fewer-component system. Clicking the second time on the j-th row sets the lumping of Component i+1 to Component j of the many component system into Pseudo-Component 2 to the fewer component system, and so on. The Undo button undoes the last mouse click. The Reset button clears the current lumping scheme. The user has control in selecting the last component Nl in the original list of the Nc component system that will be involved in the lumping. That is component 1 in the list through component Nl will be lumped. This selection is made through the group up to component combo box. The critical properties of the pseudo-components are estimated using the mixing rules of Lee and Kesler [15].
Laboratory Calculations
Overview
WinProp performs the following laboratory calculations: 1. Recombination of separator oil and gas 2. Compressibility measurements 3. Constant composition expansion 4. Differential liberation 5. Separator test 6. Constant volume depletion 7. Swelling test Descriptions of the above laboratory procedures can be found in Pedersen et al. [29] and McCain [17]. You can also include experimental data in these calculations for regression purposes. Convention for Experimental Data Input Many experimental data are entered in tabular form. You are required to enter data for all pressures or mixtures. For missing data, enter "-1.0" in the corresponding cell. The program will ignore all negative data in the regression. WinProp will put "-1.0" into empty cells corresponding to pressures or mixtures that have values in some other cells. You can also enter a negative sign ("-") in front of any piece of data to exclude it from the regression.
the EOS calculated oil phase density is generally not as accurate. A number of options in addition to the EOS are therefore provided for specifying the densities. These are 1) Entering the densities directly and 2) Use of the Alani-Kennedy correlation for calculating the oil phase density and Dranchuk et al. [4] correlation for calculating the gas phase density. Further discussion of these correlations follows in the next section. A key concern is the quality of the compositional data collected in the field for the recombination calculation. A fast and reliable way of evaluating the consistency of the data is through a graphical technique, known as the Hoffman plot [9]. This plot is created by plotting the logarithm of the product K-value times pressure versus a component characteristic factor, F. If the data is good, that is the oil and gas samples are reasonably in equilibrium at the separator conditions and the measurement of the oil and gas compositions is generally error free, then the points for components C1-C6 should fall on a straight line. Compositions corresponding to components N2 and C7+ are generally not measured as accurately. The parameter, F, is defined as follows:
F=
(log Pc log Pa )
1 1 T T c b
1 1 Tb T
Where Pc = critical pressure, Tc = critical temperature, Pa = atmospheric pressure, Tb = normal boiling point and T = Temperature Input Data Invoke the Recombination calculation option by selecting Lab|Recombination from the menu. An example data set is recombine.dat. The separator pressure, temperature and gasoil ratio are the required inputs to be specified in the text boxes under the frame labelled Separator conditions. The compositions of the separator oil and gas are also required and are entered on the form Composition, with the oil entered as the primary composition and the gas as the secondary composition. The default method is to calculate the oil and gas densities from their respective compositions and the separator pressure and temperature using the equation of state (EOS). Generally, the EOS calculated oil density is not reliable. Therefore, if an experimentally determined value for the oil density or oil specific gravity is available, enter it directly instead. In the case of specific gravity, select the button Specific gravity entered and enter a value in the adjacent text box. If the oil density is available select the Mass density entered button and enter a value in the adjacent text box in the units stipulated. A third choice is to use some model other than the EOS to predict the oil density. Since the composition is known the Alani and Kennedy correlation is a good choice. To use this method select From Alani Kennedy correlation... button and enter values of the C7+ specific gravity and molecular weight. This
88 Laboratory Calculations
method is considered to be quite accurate even for highly volatile oils. The authors used experimental density data to develop a cubic equation for the oil molar volume:
v 3 (R (T + 460) / P + b )v 2 + av / P ab / P = 0
where, v = Molar volume, ft3/lbmol T = Temperature, F P = Pressure, psia R = 10.7335, (psia) (ft3/lbmol)/R The parameters a and b depend on the temperature and on component specific constants; for pure compounds a and b are given by: a = e n / (T + 460 )
b = m(T + 460) + C
The values of , n, m and C are available in the literature for common compounds, see for example Danesh [3]. For the C7+ fraction, a and b are obtained from an equation with the specific gravity and molecular weight as well as the temperature being the inputs. Provision is made to enter the specific gravity and molecular weight of the C7+ fraction on the Recombination form. The values of a and b for the mixture are determined by molar averaging. Please refer to reference [3], page 76-77 for more extensive presentation of this material including an example calculation. For the gas density the EOS value is reliable. However, a value may be entered directly or calculated from the entered compressibility factor. A third option is to use the correlations of Dranchuk, Purvis and Robinson [4]. Two methods are available for calculating the pseudocritical temperature and pressure: Kays rule and the Wichert and Aziz correlation [42]. The Hoffmann plot for the recombination can be generated by selecting the checkbox labelled Perform Hoffmann, Crump, Hocott (HCH) Test at the bottom of the form. The gas and oil are not in equilibrium from an EOS calculation viewpoint. Thus, a separator calculation on the recombined fluid will not give the measured gas-oil ratio or oil and gas compositions. Another approach for doing recombination is to use the Separator calculation, and through a trial-and-error approach find the fraction of gas in the gas/oil mixture that will give the measured gas-oil ratio. The composition of the gas and oil are entered as the primary and secondary compositions on Form Composition. The feed is specified on the second tab of the Separator calculation by selecting the mole fraction of the primary fluid.
Laboratory Calculations 89
Compressibility Calculation
Overview This option calculates the single-phase compressibility as defined by the following equation:
c = 1 / V(V / P )
You invoke this option by selecting Lab|Single-phase Compressibility. An example data set for this option is compress.dat. Note that in the output file, compressibilities are reported under column headings labelled global and liquid. For the case where the mixture is single phase at the given pressure and temperature these two values will be the same since the global and liquid composition are identical. For the case where there are 2 phases, the compressibility under global is the overall mixture (oil and gas) compressibility calculated using the equation valid for single phase and the value under the liquid column is the oil phase compressibility. Input Data Once the primary fluid (usually oil) and secondary fluid (usually gas) compositions have been entered on the Composition form, compressibilities for any number of fluids defined by combining the oil and gas streams in different proportions can be determined. On tab 1, Calculations, enter the temperature and on the table below enter for each mixture the initial pressure, the pressure increment, the mole fraction of the secondary fluid in the mixture and the number of pressure steps. The experimental compressibilities can be entered on the table provided on tab 2, Experimental. Note that this table accommodates all the mixtures defined on the previous tab. If a given experimental value is not available, enter a value of 1.0. In the example data set compress.dat, compressibility calculations are carried out for four fluid mixtures. For each mixture, the compressibility of the fluid is calculated for three pressures equal to 24000 kPa, 25000 kPa and 26000 kPa respectively.
90 Laboratory Calculations
Input Data You invoke this option by selecting Lab|Constant Composition Expansion. Alternatively add the option by clicking on the CCE button on the options toolbar. An example data set is cce.dat. Enter data on tab 1, Pressure Levels. For a description of the data entry related to the saturation pressure fields, please refer to the section entitled Saturation pressure. The reservoir or experimental temperature is entered in the text box labelled Temperature. The pressure levels of CCE test are entered on the table provided under column 1 labelled Pressure. Enter values starting with the highest pressure to the lowest. At least one value is required. The following experimental data can be entered for regression for this option: For a bubble point fluid: 1) Relative total volume ( total fluid volume at current pressure / fluid volume at saturation conditions) above and below saturation conditions, dimensionless quantity, 2) Liquid saturation as a percentage (volume occupied by the liquid phase / total cell volume * 100) above and below saturation conditions, dimensionless quantity, 3) Oil viscosity above and below saturation conditions in cP, 4) Gas viscosity below saturation pressure in cP, 5) Gas compressibility factor below saturation conditions (dimensionless), 6) Oil compressibility factor above and below saturation conditions (dimensionless), 7) Gas density below saturation conditions, in units of kg/m3 for SI units and lbm/ft3 in field units, 8) Oil density above and below saturation conditions, in units of kg/m3 for SI units and lbm/ft3 in field units, 9) Single phase oil compressibility, at and above saturation conditions, in units of 1/kPa for SI units and 1/psia in field units. For a dew point fluid: 1) Relative total volume ( total fluid volume at current pressure / fluid volume at saturation conditions) above and below saturation conditions, dimensionless quantity, 2) Liquid saturation as a percentage ( volume occupied by the liquid phase / total cell volume * 100) above and below saturation conditions, dimensionless quantity, 3) Oil viscosity below saturation conditions in cP, 4) Gas viscosity above and below saturation pressure in cP, 5) Gas compressibility factor above and below saturation conditions (dimensionless), 6) Oil compressibility factor below saturation conditions (dimensionless), 7) Gas density above and below saturation conditions, in units of kg/m3 for SI units and lbm/ft3 in field units,
Laboratory Calculations 91
8) Oil density below saturation conditions, in units of kg/m3 for SI units and lbm/ft3 in field units. If experimental values are not available at all pressure levels for a given data type, a value of -1.0 may be entered for the unknown values. Please see also the section on Convention for experimental data input. For a given piece of data if the corresponding (predicted) value cannot be calculated, for example single phase compressibility for a dew point fluid, then that specific piece of data will not be included in regression.
Differential Liberation
Laboratory Procedure This procedure is generally performed for a black-oil fluid to simulate the conditions encountered in the reservoir. The sample of reservoir liquid in the laboratory cell is brought to the bubble point pressure, and the temperature is set to the reservoir temperature. Pressure is reduced by increasing the cell volume. All the gas is expelled from the cell while pressure is held constant by reducing the cell volume. The gas is collected, and its quantity and specific gravity are measured. The process is repeated in steps until atmospheric pressure is reached. The temperature is then reduced to 15 C or 60 F, and the volume of the remaining liquid is measured. This corresponds to the residual oil from the differential liberation. Each of the values of liquid volume in the cell is divided by the volume of the residual oil to obtain the relative oil volume or formation volume factor, Bo. The compressibility of the gas (Z-factor), the gas density and the formation volume factor of gas (Bg) are also measured. The total volume of gas removed during the entire process is the amount of gas in solution at the bubble point. The solution gas-oil ratio (Rs) is calculated by dividing the total volume of gas by the volume of residual oil. The solution gas at any lower pressure is obtained by subtracting the sum of gas removed down to the pressure of interest from the total volume of gas removed. A schematic of the differential liberation process is shown below:
Gas off
All gas displaced
Gas Gas Oil Oil Oil Oil Hg Hg Hg P 1 = P sat P 2 < P sat P 2 < P sat P 2 < P sat Hg Hg P 3 < P 2 < Psat
User's Guide WinProp
Gas
Oil
92 Laboratory Calculations
Input Data This option is invoked by selecting Lab|Differential Liberation or by selecting the DIFF LIB button on the options menu. An example data set is diflib.dat. Also the data set, matbalbo.dat illustrates consistency checks calculations for the differential liberation experiment. You enter data on Tabs Pressure Levels, Consistency Checks and Feed/Kvalues/Output level/Stability test level/Standard Conditions. On Tab 1, Pressure Levels, for a description of the data requirements for the saturation pressure related fields, specifically the saturation pressure entered on the first row and first column of the main differential liberation table and the check box labeled improve saturation pressure estimate, please refer to the section entitled Saturation Pressure. The standard conditions are entered on Tab 3. The default values are 14.696 psia and 60 F or 101.325 kPa and 15.56 C. The basic data required on the tab Pressure Levels are the temperature and the pressure levels. Enter the reservoir temperature in the text box labeled Temperature. Enter the pressure levels in column one of the main table. At least one pressure level must be specified in addition to the saturation pressure. Note that row one is reserved for the saturation pressure. The specified pressures on row two and subsequent pressures may be higher than the saturation pressure. However, for rows 2 and greater specify the pressures from the highest value to the lowest. Do not leave any empty rows. Quite often experimental data such as oil specific gravity (SG), oil formation volume factor (FVF), solution gas-oil ratio (GOR), gas Z-factor, gas formation volume factor, gas specific gravity, oil and gas viscosities as well as properties of the residual oil are available from the laboratory. These data may be used in WinProp in two ways: 1) Material balance and consistency check calculations to evaluate the quality of the data and 2) In regression to tune the EOS model to match the observed data. Generally, material balance calculations would be done first to evaluate the data prior to the regression calculation. The required data for performing an overall material balance are the gas oil ratio at each step, the specific gravity of the gas at each step, the specific gravity of the oil at saturation conditions, oil formation volume factor at saturation conditions and the residual oil specific gravity. For component material balances the gas phase composition at each stage is also required. Please note that in going from reservoir temperature and standard pressure to standard temperature and pressure, it is assumed that no gas will be evolved. The component balance calculates the composition of the oil phase in the cell at each stage of the experiment. These data are entered on Tab 2, Consistency Checks. The data fields required to be filled for overall material balance calculations are shown in cyan. For component material balance in addition to the data for performing the overall material balance, the gas composition for each step of the differential liberation experiment is also required. These fields are shown in yellow. Since some of the data measured in the laboratory can be used for both regression and for material balance calculations, a button on Tab 2 labeled, Copy Main Table Contents is provided to avoid having to specify the same data twice on the main table on Tab 1 and the consistency checks table on Tab 2. The pressure values however have to be entered on the main table on Tab 1. Therefore if the experimental data are initially entered on the main table, then clicking on the command button Copy Main Table Contents will copy
User's Guide WinProp Laboratory Calculations 93
the common data from the main table to the consistency checks table. If sufficient data is entered for the material balance then WinProp will automatically perform that calculation. Similarly if sufficient data is entered for component material balance then that calculation will be performed by WinProp. However the user has the option to suppress the consistency or material balance checks by checking off on the check box labeled Perform consistency checks if sufficient data is entered on Tab 2. Data for regression can be entered on columns 2 through columns 9 of the main table on Tab 1 as well as the residual oil specific gravity and API gravity text boxes on Tab 1. For a given property such as GOR if experimental data is not available for a given pressure, then enter a value of -1.0 for that row. A table below the main table on Tab 1 can be used to assign weights to the different types of data entered. Please see also the section on Convention for experimental data input. If data has been entered on Tab 2 that the user would also like to use for regression purposes then clicking on the button labeled Copy Consistency Checks Table will copy the data in fields common to both tables. The table import wizard may also be used to import data from an ASCII or Excel format file into the main table on Tab 1. To invoke the table import wizard, click on the button labeled Table Import Wizard. On Tab 1 there is a checkbox labeled Scale ROV and GOR to oil shrinkage and cum. Gas released relative to bubble point. Selecting this option will enable calculation of oil shrinkage as the ratio of oil volume to saturated oil volume, and cumulative gas released as the ratio of standard volumes of gas liberated to saturated oil volume. If the Differential Liberation calculation is not being used in regression, this option will generate a plot of these quantities vs. pressure when the Excel plots are generated, in addition to the normal Relative Oil Volume and Gas-Oil Ratio plot. If regression to experimental data is being performed, the experimental values are converted to oil shrinkage and cumulative gas released, and the regression is done on these quantities. The regression summary table will show the match to the scaled quantities, and the regression summary plots will show the fit to both the scaled and un-scaled quantities. The advantage of this technique is that the EOS will not be penalized for poor prediction of the residual oil density, which is a quantity that will never be encountered in the field.
94 Laboratory Calculations
Gas off
Gas
Gas
Gas
Input Data You invoke this option by selecting Lab|Constant Volume Depletion from the menu or by selecting the CVD button on the options toolbar. An example data set is cvd.dat. For illustration of consistency checks calculations on CVD experimental data, see the template case, matbal-gc.dat. You enter data on Tabs Pressure Levels, Consistency Checks, Separator and Feed/K-values/Output level/Stability test level. On tab 1, Pressure Levels, enter the reservoir or CVD test temperature in the text box labeled Temperature. For this test, an initial guess for the saturation pressure is required. This value is entered on row 1 and column 1 of the main table on Tab 1. The program can use this value directly in a saturation pressure calculation or refine the guess with a stability test. The latter choice is selected by checking off the check box labeled improve saturation pressure estimate. Further details are provided in the section entitled Saturation Pressure. The only other required data are the values of the pressure steps. These are entered in the column labeled Pres. on the main table provided on Tab 1. The first row of this table is reserved for the saturation pressure. Enter values from highest pressure to the lowest pressure starting on row 2. Do not leave any empty rows. Columns 2 through 4 are to be used for entering experimental data which can be used for regression. On the column labeled Cum Gas produced (%), enter the percentage recovery, that is total moles removed as a percentage of the initial moles (at saturation pressure) charged to the cell. On the column labeled Liq. Sat (% of CVS) enter the percent of the cell volume occupied by the liquid phase at each pressure step, relative to the volume occupied at saturation conditions. For fluids with a dew point, at saturation pressure, this value is 0.0. For volatile oils which exhibit a bubble point enter a value of 100 at the saturation pressure. On the column labeled Gas Z factor enter the gas phase compressibility factor at each pressure. For a given property such as Gas Z factor if experimental data is not available for a given pressure, then enter a value of 1.0 for that row. A table below the main table on Tab 1 can be used to assign weights to the different types of data entered. Please see also the section on Convention for experimental data input. If data has been entered on Tab 2, Consistency Checks, that the user would also like to use for regression purposes then clicking on the button labeled Copy
User's Guide WinProp Laboratory Calculations 95
Consistency Checks Table will copy the data in fields common to both tables. The table import wizard may also be used to import data from an ASCII or Excel format file into the main table on Tab 1. To invoke the table import wizard, click on the button labeled Table Import Wizard. Material balance calculations can be used to check the quality of the laboratory data collected. The overall material balance can be used to determine the total mass of the gas and liquid phases and their densities as a function of pressure. If the compositional analysis of the gas phase from each stage is also available then the liquid phase composition at each stage can also be calculated. These data are entered on Tab 2, Consistency Checks. The required data for performing an overall material balance are the cumulative percent recovery at each pressure step, the Z factor of the gas at each pressure step, the specific gravity of the gas at each pressure step and the liquid saturation at each pressure step. The data fields required to be filled for overall material balance calculations are shown in cyan. For component material balance in addition to the data for performing the overall material balance, the gas composition for each step of the constant volume depletion experiment is also required. These fields are shown in yellow. Since some of the data measured in the laboratory can be used for both regression and for material balance calculations, a button on Tab 2 labeled, Copy Main Table Contents is provided to avoid having to specify the same data twice on the main table on Tab 1 and the consistency checks table on Tab 2. The pressure values however have to be entered on the main table on Tab 1. Therefore if the experimental data are initially entered on the main table, then clicking on the command button Copy Main Table Contents will copy the common data from the main table to the consistency checks table. If sufficient data is entered for the material balance then WinProp will automatically perform that calculation. Similarly if sufficient data is entered for component material balance then that calculation will be performed by WinProp. However the user has the option to suppress the consistency or material balance checks by checking off on the check box labeled Perform consistency checks if sufficient data is entered on Tab 2. A brief description of the material balance calculations for CVD follows below. For more detailed information please refer to Whitson and Torp [41]. Assume as a basis 1 mole of initial fluid charged to the CVD cell. The total mass in the cell at a particular stage k, denoted as ntk is then equal to:
n tk = 1 n pi
i=2 i=k
where npi is the incremental moles of vapor produced from the cell during stage i. In terms of the table entries, npi is the difference in the values of gas produced % expressed as fraction between stage i and stage (i-1). Note the initial stage (saturation conditions) is being denoted as stage 1. The corresponding material balance equation for a component j is:
n tk z jk = z j1
i=k i=2
n pi .y ji
where zjk is the overall composition of the fluid remaining in the cell at stage k and yji is the composition of the vapor phase removed from the cell at stage i. For density calculations the mass and volume of each phase in the cell is required. The cell volume can be calculated from the knowledge of initial fluid properties:
96 Laboratory Calculations
Z RT Vcell = 1 P1
For gas condensates the gas compressibility factor Z1 is generally available, for volatile oils, however, the bubble point density is usually measured. Provision is made to enter Z factors only in WinProp. The measured bubble point density can be used together with the real gas law (PV=nZRT) to obtain the required Z factor. At each stage the liquid volume in the cell is measured and reported as the liquid saturation. The liquid volume in the cell, can then be calculated as:
VLk = S Lk .Vcell
From a volume balance, the vapor volume is then Vvk = (1-SLk).Vcell. Using the real gas law, the corresponding moles of vapor in the cell at stage k are calculated as nvk = pk.Vvk/ZkRT. The composition of the liquid phase remaining in the cell at each stage k can now be computed as:
x jk = n tk .z jk n vk .y jk n tk n vk
The compositions calculated in this manner are analyzed by plotting the corresponding logarithm of K values versus a component characterization factor, F, known as the Hoffman plot. WinProp will automatically create this plot if component material balance calculations are performed, which will be done if the required data is entered by the user. The densities of the liquid and vapor phases can also be calculated from a mass balance [41]. The multistage separator conditions and standard conditions are entered on Tab Separator. Enter stages from the highest pressure down to the lowest pressure. A maximum of 8 stages excluding stock tank are allowed. The multistage separator does not include the stock tank conditions which are entered as Standard conditions. A lower carbon-number component and an upper carbon-number component are also specified. The molecular weight of components between those two is computed at each pressure level. This enables the tracking of the molecular weight of the plus fraction during the depletion process. You can also enter experimental data on mole % of gas produced, liquid dropout (% liquid saturation), and gas compressibility factor for regression purposes. Please see also the section on Convention for experimental data input.
Separator Test
Laboratory Procedure The reservoir fluid is sent to a multistage separator where the pressure and temperature are selected to optimize liquid production. The last stage of the separator corresponds to the stock tank. A schematic of a conventional three-stage separation process is shown below:
Laboratory Calculations 97
GAS (ST)
The overall gas-oil ratio, the stock-tank specific gravity or API, and the oil formation volume factor Bo are measured. The implementation of the Separator option provides for considerable flexibility in modelling separation strategies which do not conform to the conventional scheme described above. This is often encountered with gas condensate fluids. Each separator has the limitation of a single required input and two outputs corresponding to the vapor and liquid streams. However the liquid output need not feed the next separator and the gas output is not limited to join the gas product stream. For a given separator one of these output streams can potentially become a product stream or feed a separator downstream. Recycling is not allowed. The user can also specify new product streams aside from oil and gas such as LPG. The oil and gas product streams however must always be present. Quantities that can be used for regression calculation such as GOR will always therefore be defined. Two examples via schematics are shown below of alternative separator calculations. In the first case the oil product stream is made up of contributions from the liquid phase from the 3 separators. This is essentially a reversal of the conventional case where the gas product stream is made up of the vapor phase from all the separators. In the second case a third product stream labeled as LPG is defined.
GAS
FEED
1st STAGE P1 , T1
2 nd STAGE P 2, T2
STOCK-TANK P s , Ts OIL
LPG GAS
FEED
1 st STAGE P1 , T1
2 nd STAGE P 2, T2
STOCK-TANK P s , Ts OIL
98 Laboratory Calculations
Input Data This option is invoked by selecting Lab|Separator or alternatively by selecting the SEP button on the options toolbar. An example data set is separator.dat. Specification of the separator stage conditions and stage data for performing Hoffmann plots and material balance calculations is done on tab 1, Separators. Initially there are 2 columns corresponding to the saturation conditions and stock tank conditions in the table on tab 1. The minimum data requirements are the temperature and pressure for each defined stage. For the saturation column, the reservoir temperature is required along with the known saturation pressure or an initial guess for the saturation pressure. The program will calculate the saturation pressure. The user-supplied value will be used directly as an initial guess in the saturation pressure calculation or the user-supplied value will be refined further via a stability test prior to the saturation pressure calculation being invoked. The default is to refine the initial value as indicated by the check box labelled improve saturation pressure estimate. For the stock tank, the default values for the temperature and pressure are shown on the table. The user may edit these values. The Liquid to and the Vapor to rows indicate the destination of the liquid and the vapor stream from each stage. When there is only one stage, stock tank, then these destinations have to be the oil product stream and the gas product stream since these 2 streams have to be present in all cases. For reporting volumes, conditions other than the stock tank pressure and temperature can be selected for each product stream. These are to be specified in the table labelled Product Streams Reporting Table. To add a separator, select a cell in the column where you want the new stage to be inserted and click on the button labelled Insert sep. To delete a separator, highlight the appropriate column(s) and click on the button Delete sep. The highest separator stage should be added first followed by lower pressure stages to the stock tank. The default destination for the liquid phase is as feed to the next separator downstream while the default for the vapor phase is the gas product stream. Once all the separators are added and the conditions specified then the destinations can be changed, possibly defining a new product stream such as an LPG or intermediate product stream. This is done through a drop down combo box which pops down by double clicking or entering data on the appropriate cell of the stream destinations table. Once added, such a stream will also have an entry added to the Product Streams Reporting Table. An example of the interface is shown below:
Laboratory Calculations 99
For overall material balance calculation and Hoffmann plots the required data are the specific gravity of the gas removed from each separator stage, the gas oil ratio (with respect to stock tank oil) at each stage, the stock tank API, the density at the saturation conditions and the oil formation volume factor at saturation conditions. For component material balance calculations the composition of the gas stream from separator stage is required as well. The GOR values correspond to the amount of gas liberated and not gas in solution. The formulation of the material balance equations is based on the fact that the mass or moles placed at the start of the experiment must equal the mass of the residual oil plus the mass of gas removed from the cell [18].
M init
The above equations all yield mass of initial in place fluid, gas removed and residual oil in units of kg. The gas oil ratio appearing in the expression for the gas removed in stage k is the liberated GOR and k is the specific gravity of the gas coming out of solution in stage k. stc is the stock tank density of the oil and s is the saturated fluid density. Bo is the formation volume factor at saturated conditions.
The experimental data for regression are entered on tab 2, Experimental Data. The three experimental data values available for regression are the overall solution gas oil ratio, the oil formation volume factor and the residual oil API gravity.
Swelling Test
LABORATORY PROCEDURE This experiment provides information on the fluid behavior under gas injection processes. When a gas is injected into a reservoir, it can go into solution and swell the oil, i.e. the volume of the oil becomes larger. Measurements of this effect can be performed as follows. The reservoir oil is loaded in a cell, and the temperature is set at the reservoir temperature. The bubble point of the oil and the corresponding volume are measured. A small amount of injection gas is transferred into the cell. A new saturation pressure is determined and a new saturation volume recorded. This process is repeated until the upper bound of injection-gas concentration is reached or the saturation pressure of the fluid is equal to the estimated injection pressure. A constant composition expansion experiment may be performed for each mixture of injection-gas and oil in the above process. Input Data This option is invoked by selecting Lab|Swelling Test or alternatively by clicking on the SWL TEST button on the options toolbar. An example data set is swelling.dat. Enter data on Tabs Mixtures and CCE. The required data on Tab 1, Mixtures, include the temperature at which the experiment is performed and an initial guess for the saturation pressure of the oil at the specified temperature. If the Improve saturation pressure estimate box is checked this value will be refined further via a stability test. For additional details refer to the section entitled Saturation Pressure. The original oil is labelled as mixture #0. The initial guess for saturation pressure entered in the text box Saturation pressure is also shown on the table on Tab 1 to be used to specify the data for the other mixtures. The oil and gas compositions are entered on the Composition form as primary and secondary fluids respectively. The data on Tab 1, Mixtures, corresponding to template case swelling.dat is shown below.
On the table provided for specifying mixture properties, the first column corresponds to the mole fraction of injection gas, and the second column corresponds to the saturation pressure estimate of the injection-gas and oil mixture. The row corresponding to the original oil, that is with mole fraction equal to zero, is added automatically by WinProp. The saturation pressure estimate value appearing in the table for this row is taken from the Saturation Pressure Estimate text box. Additional data for at least one mixture is required on this table. Enter data for these mixtures in consecutive rows starting with the smallest value of the gas mole fraction to the largest value. A guess for the corresponding saturation pressure is required for each mixture. As data is added to the table, the total number of mixtures defined is indicated by the label No of swelling experiments. Insert or remove rows from this table by accessing the Table menu. The above example shows a case with 5 mixtures. For regression purposes, the experimental saturation pressure data and/or swelling factor (volume of swelled fluid at saturation pressure/volume of original fluid at saturation pressure) may be entered in the third and fourth columns respectively. Either of the two properties may be assigned a weight greater than the default of 1.0 reflecting the relative importance of the data to the process for which the EOS model is being developed or the relative accuracy of the measurements. Please see also the section on Convention for experimental data input. If required, the pressure levels of a constant composition expansion process are entered on Tab CCE. The CCE experiment will be performed at the entered pressures for each of the mixtures stipulated. The CCE Excel plots are generated automatically if pressures are specified for the CCE experiment.
Overview
The design of gas or solvent injection processes often involves a multiple-contact calculation to study the vaporization or extraction process. There are two methodologies to analyze the gas drive mechanism and miscible process in WinProp. Traditionally, with cell-to-cell simulation, a pseudo-ternary diagram is generated from the calculations to help with the interpretation of the results. Most gas or solvent injection floods operate in a regime where true miscibility is not achieved, rather near miscible conditions are realized. High recoveries can be achieved even though miscibility is not truly realized. As compared to conditions required for miscibility, operation in this regime translates to lower operating costs as compression costs increase with pressure and feedstock costs increase with the solvent enrichment level. These are known as vaporizing/condensing processes (Zick [44]), and the resulting ternary diagram has an hourglass shape. By analyzing the ternary diagrams from the MCM option in conjunction with slim tube or core flood experiments, optimal operating conditions or solvent composition can be determined. Please refer to Nutakki et al. [25] for a detailed discussion of this subject. Besides the pure vaporizing or pure condensing processes, there is a combined drive mechanism that has features of both vaporizing and condensing drives. In such a system, the crossover tie line controls the development of miscibility, instead of initial oil tie line or injection gas tie line. Geometric construction in the composition space is used to locate
calculation, the program divides the entered pressure range into 400 equally spaced intervals. The calculation begins with the lowest pressure (Pmin) terminating at the maximum pressure (Pmax) or at the FCM pressure. Similarly for the MME calculation, the entered mole fraction range is divided into equally spaced intervals, and the calculation terminates at the maximum solvent enrichment level, or at the enrichment level which gives first contact miscibility at the specified pressure. The results are output based on the pressure step, or mole fraction step, used to specify the range and at the pressure corresponding to the MMP or MME. If Cell-toCell method is used, the ternary diagrams will also be output. If Tie Line method is used, detailed liquid/vapor composition, as well as the k-value for each key tie line will be output.
Data Input
The multiple-contact calculation option is invoked by selecting Calculations|Multiple Contacts or by selecting the MCM button on the options toolbar. Example data sets for this option are mcm-condensing.dat, mcm-vaporizing-co2.dat, mcm-combined-H95-8leanmmp.dat and mcm-Z12-5-mme.dat etc. The required data include the temperature, entered in the text box on Tab 1, Conditions and a pressure or alternatively a pressure range for the calculation. For calculation at a single pressure, enter the value in the text box Pressure. To specify a pressure range enter the minimum pressure, Pmin, in the text box labelled Pressure and enter a value for pressure step, Pstep, and the number of pressure steps, Nsteps. The maximum pressure, Pmax = Pmin + Pstep *Nsteps. The user needs to select one of the calculation methods: Cell-to-Cell simulation or Tie Line method. The other required data are the oil composition entered on the Composition form, the primary and make up gas compositions entered on Tab 2, Composition, the make up gas fraction or range of fractions and the pseudoization scheme for the ternary diagram entered on Tab 2, Composition as well. For calculation at a single solvent enrichment level, enter a value between 0.0 and 1.0 in the Make-up gas fraction text box. The default value for the make-up gas fraction is zero, implying the solvent composition equals the primary gas composition. In this case the makeup gas composition is not required and values of zero can be entered. To specify a range of make-up gas mole fractions, enter the minimum value in the Make-up gas fraction text box, enter a value for the Make-up gas fraction step and for the No. of make-up gas fraction steps. If Cell-to-Cell simulation is selected, the pseudoization scheme need to have a value of 1, 2 or 3 to group a given component into the first, second or third pseudo-component respectively. The pseudoization scheme is used in the post-processing step, which is just for ternary plots; the actual calculations are done with the full set of components. Note that if a range of pressures is specified (MMP calculation), only one solvent composition may be entered. That is the Make-up gas fraction step must be 0.0 and the No. of make-up gas fraction steps must be 1. Similarly for the MME calculation where a range of make-up gas fractions is specified, only one pressure value may be entered. The following steps are used in the calculation (the points referred to by letter are shown on the diagram following step 4). 1. A solvent is first formed by mixing a primary gas (e.g. dry gas) with a specified mole fraction of make-up gas (e.g. LPG). The compositions of the primary and make-up gases, and the fraction of make-up gas are entered on Tab Composition. The oil composition is specified on the form Composition.
106 Multiple Contact Miscibility Calculations
2. Solvent is added to the oil such that the solvent to oil molar ratio increases by a specified value for each mixture. This solvent increment ratio is entered on Tab Conditions as Solvent increment ratio. The default value is 0.01. Flash calculations are performed for a maximum of 100 mixtures of solvent and oil. If no two-phase region is detected, the process is judged to be first contact miscible and the calculations stop. In the event that a two-phase region is encountered, the calculation procedure proceeds to Steps 3 and 4. 3. Using the first point (A) in the two-phase region detected in Step 2, all liquid is removed. The remaining gas is combined with the original oil in the gas oil ratio RATIO:(1-RATIO) to form B1. The value of RATIO is entered on Tab Conditions as Equilibrium gas/original oil mixing ratio (default value: 0.10). A flash calculation is performed, and the liquid is removed. The procedure is repeated. This simulates a vaporizing or extraction process, and generates the portion of the phase envelope marked B. A maximum of 50 flash calculations is performed. 4. Again, using the first point (A) in the two-phase region detected in Step 2, all vapor is removed. The remaining liquid is combined with the original solvent in the solvent liquid ratio RATIO:(1-RATIO) to form C1. A flash calculation is performed, and the vapor is removed. The procedure is repeated until the oil cannot be enriched further or after a maximum of 50 flash calculations are performed. This process simulates a condensing gas drive process, and generates the portion of the phase envelope marked C.
Heavy
B C
Oil
C1 B2 B1
C2
Critical Point
Light
Dry Gas
Solvent
Pseudo-Ternary Diagram
Intermediate
If Cell-to-Cell simulation is selected, the last column of the table on Tab Composition needs to have a value of 1, 2 or 3, which determines the grouping of components into three pseudocomponents for the ternary diagram. In the following example:
N2 and C1 belong to Pseudo-Component 1; IC5, NC5, NC6 and FC20 belong to PseudoComponent 3, while the remaining components belong to Pseudo-Component 2. The resulting ternary diagram from this multiple contact calculation is shown below, where the bottom left apex corresponds to Pseudo-Component 1, the bottom right apex corresponds to Pseudo-Component 2 and the top apex represents Pseudo-Component 3.
Regression
Overview
The regression feature of WinProp can be used to tune the equation of state to match experimental measurements. The parameters used in the regression are component properties and interaction coefficients. Most of the calculation options of WinProp allow experimental data to be entered for regression purposes. WinProp uses the regression procedure of Agarwal et al. [2]. From the specified list of parameters, the procedure orders the parameters such that the most sensitive parameters are used first. The regression is performed on a small number of parameters at a time. The default is to use a subset of 5 parameters, although this number can be modified. Once a parameter reaches the maximum or minimum value allowed or does not contribute any longer to improving the match, it is replaced by the next parameter that has not been used from the ordered list. Thus, a large set of parameters can be specified, and WinProp will regress on a small number of parameters at a time, working from the most sensitive parameters to the least sensitive parameters.
Regression 111
Example data sets for regression begin with the word regress. There are 16 template cases that involve regression from regress-blackoil1.dat through regress-separator.dat. Please refer to the introduction section for a brief description of each of these data files. Note the forms named Regression Parameters and End Regression in the Forms column. The calculation options between these two forms contain experimental data for regression. The form Regression Parameters is inserted by selecting Regression| Start while the form End Regression is included by selecting Regression|End. The experimental data are entered on the appropriate tables or text boxes in each calculation option. A weight is associated with each data item or group of data. The weights wi are used to assign a degree of importance to each data point. The default value is 1.0. A larger value gives more importance to the data while a lesser value gives less importance. The regression is performed by minimizing the objective function
where xi,calc and xi,meas correspond to the calculated value and measured value respectively. To exclude any measured value from the regression, precede it with a negative sign ("-"). Please see the section on Convention for experimental data input. All calculations before the form Regression Parameters use the parameter values before regression. All calculations after the form End Regression form use the parameter values after regression. For the calculation options that are included in the regression, the output and plots contain both results before and after regression. In the above example, the CMG GEM EOS Model option was used to print component properties before and after the regression (see the section on GEM fluid model generation and component properties printing).
Parameter Selection
Component properties for regression are selected on tab Component Properties of the Regression Parameters form.
112 Regression
Select or unselect the component properties by clicking on the grid. Clicking the first time selects the property. Clicking a second time unselects that property. If temperature dependent volume shifts have been activated on the component form, then volume shift will not be available as a regression parameter. Non-zero values of the aqueous phase solubility parameters, reference Henrys constant and molar volume at infinite dilution, must be set on the component form to enable these variables as regression parameters. The mole fraction of the secondary stream used to define the feed for calculation options can be selected as a regression variable be clicking the checkbox below the grid. Interaction coefficients are selected as regression parameters on tab Interaction Coefficients.
The interaction coefficients between hydrocarbon components are calculated from the equation described in section Interaction coefficients in the Chapter Components. The HC-HC Int. Coef. Exponent is an important parameter for matching reservoir fluid saturation pressure. The list of HC-HC groups, defined earlier via the Component Selection/Properties form is shown in the list box under the frame with the caption Hydrocarbon Groups. To select specific groups as regression parameters, first select the option button labeled Select from list and then highlight entries from the list by holding down the CTRL key and clicking with the left mouse button. The interaction coefficients involving non-hydrocarbon components are selected by clicking on the grid. Parameters specific to the viscosity correlations are selected on the tab Viscosity Parameters. As discussed in the Components chapter, there are two types of viscosity correlations available in WinProp: Jossi-Stiel-Thodos (JST) and Pedersen. When JST is being used, the correlation coefficients and the component critical volumes for viscosity are available to be selected as regression parameters. When the Pedersen correlation is active, only the correlation coefficients appear as possible regression variables on this tab. Both correlations also depend on the component critical pressures, critical temperatures and molecular weights. By leaving these values fixed, however, and regressing only on the parameters appearing on the viscosity parameters tab, the process of matching experimental viscosity data can be completely decoupled from the process of tuning the EOS to PVT data.
User's Guide WinProp Regression 113
Second set EOS parameters can be specified as regression variables in the same way as the first set. The user can toggle between the component properties and interaction coefficient tables belonging to the first and second set through the set selection menu. To activate second set when the first set is active select SetSelection|Second Set. The second set regression variables currently supported are the critical pressure, critical temperature, volume shift, omega A, omega B, interaction coefficient exponent and the binary interaction coefficients for pairs with a nonhydrocarbon species. The user does not need to enable the second EOS set through the Component Selection/Properties form to specify second set regression parameters. The second set is activated automatically when a second set regression variable is selected. The default variable bounds for a given property are the same regardless of which set the component belongs to. The selection of bounds is discussed in more detail below. The grouping feature discussed below can also be used for the second set parameters.
To activate grouping select Grouping|Start group selection and select the components to be included in the group by clicking on the appropriate grid cells for a particular property such as acentric factor. Instead of the X to indicate a selection, for a group member a group id such gr #1 will be assigned. Once all the members are selected click on a different column or select End group selection from the Grouping menu. To delete a group click on all the individual cells defining the group or select Grouping|Delete group and then click on a cell corresponding to any member of the group. To edit a group, erase the existing definition of the group by deleting the group, and start again. The Component Properties tab for a regression run specifying the critical pressures and volume shifts for the last 4 components in the plus fraction as grouped variables is shown below:
Regression 115
To give experienced users the flexibility to restrict the variation of certain component properties and allow larger changes in others, however, the default variable bounds can be edited on this table. As mentioned above, changing the bound of a group member may lead to the bound for the reference component of the group (first group component in the list) to be adjusted automatically. The user can revert to the WinProp defaults for the bounds by clicking on the Reset to Default Bounds button.
Number of parameters to be regressed on at one time. The default value is 5. If the number of regression parameters is less than this number, the former will be used instead. Note that increasing this value can significantly increase the run time for the regression.
Under Grouping Controls an option is given to specify how the members of a group are varied during regression. Selecting Vary group variables by equal increments specifies that a change x will be applied to all group members as xnew = xold + x. Selecting Vary group variables by equal ratios specifies that all group members will be multiplied by a common factor as xnew = xold x F. The default method is to vary the group members by equal increments.
116 Regression
The contents of the (.rls) file can be used to update the component properties in the current data set by selecting File|Update component properties. Three forms: Titles/EOS/Units, Component Specification/Properties and Composition forms are updated. The Regression Parameters and End Regression forms can now be removed from the file, and prediction of phase behavior using the tuned model can be performed. To keep a record of the work done use File|Save as... to save this file with a different name, e.g. regress1.dat. Note that a number of back to back regression runs can also be performed in this way with same data but using different regression variables. A similar procedure applies to Plus Fraction Splitting and Component Lumping in terms of updating component properties.
Regression 117
Compositional Grading
Overview
The compositional grading phenomenon refers to a variation in fluid composition with depth in a reservoir. As depth increases the mole fraction of light components decreases, density increases and GOR decreases. Near critical oils and volatile fluids exhibit the largest compositional grading effects, while black oils have the least variation in properties with depth. Compositional grading is reduced if the system is highly undersaturated. Assessment of compositional grading is important in estimation of fluid in place, initialization of reservoir simulators and consideration of production alternatives. For example, when considering gas injection in a reservoir with compositional grading the solvent composition required to achieve miscibility will vary with depth. There are two model formulations available for performing the compositional gradient calculation: the isothermal model or the thermal model. The isothermal compositional gradient calculation solves the gravity/chemical equilibrium problem. Given the composition and pressure at a reference depth, the composition and pressure at any other specified depth can be determined. The saturation pressure at the specified depth is also calculated. If there is transition from bubble point to dew point saturation conditions over the calculation interval, the GOC depth will be estimated. This is done with a simple halving algorithm to locate the depth at which the transition from bubble point to dew point occurs. This ultimately requires saturation determination in the vicinity of the critical point, which can cause failure of the saturation calculation. The GOC calculation continues until an interval of 0.1m is reached or until the saturation calculation fails. For this reason, the accuracy to which the GOC depth was determined is reported in the summary table. Formulation of the problem and the required solution algorithms are given in Whitson and Belery [39]. The thermal model incorporates the effect of the geothermal temperature gradient on the compositional gradient. Thermal diffusion effects as well as the variation of fluid properties as a function of temperature can be included in the model. As for the isothermal model, the location of the GOC will be estimated if it exists. When the temperature is not constant, the system is not in equilibrium. The model solves for a stationary state, or zero mass flux condition, as described in Hoier and Whitson (SPE 63085). Please note that the equation of state must predict a single-phase system for the reference composition at the reference pressure. If the system is unstable, the calculation cannot be performed. If experimental data indicate that the initial condition should be stable, some EOS tuning may be required before the compositional gradient calculation can be carried out.
With the default output level of 1, only the summary table is shown in the output (.out) file. This gives the reservoir pressure, saturation pressure, density and two key mole fraction values as a function of depth. With output level 2, for each depth the full phase property table and the saturation calculation results are printed in addition to the summary table. When the detailed output is requested it will be printed in the order the calculation is carried out which is described below. The calculation is carried out in the following order: 1. The first depth level above the reference depth is calculated, using the reference conditions as the initial guess for the calculation. 2. Continuing for each depth level from the first calculation to the top of the interval, each calculation is performed using the previous converged results as the initial guess. 3. The first depth level below the reference depth is calculated, using the reference conditions as the initial guess. 4. Continuing for each depth level from the calculation in step 3 to the bottom of the interval, each calculation is performed using the converged results from the previous calculation as the initial guess.
Data Input
Example data sets for the compositional grading calculation are given in compgrad-blackoil.dat and compgrad-voloil.dat. For field units, temperature is entered in F, pressure in psia and depth in feet. For SI units, temperature is entered in C, pressure in kPa and depth in meters. For Feed, K-values, Output level and Stability test level specifications, see the Chapter Common Data Required for all Options. Specification of the primary calculation options is done on tab General. Enter the reservoir temperature at the reference depth in the text box Reference Temperature. In the text box Reference Pressure enter a value for the pressure corresponding to the reference depth entered in text box Reference Depth. Enter the depth to the top and bottom of the formation in text boxes Depth to Top and Depth to Bottom respectively. The total height of the fluid column as defined by these depths is divided by the number of calculation intervals specified in the text box No. of Calculation Intervals to determine the evenly spaced points at which the calculation is performed. The default value is ten. If the user desires the calculation to be performed at certain specific depths, these can be entered in the table provided. Enter each depth in the column headed Depth Value. The user can monitor the composition changes with depth for a given component or a range of components. This information will be printed in the summary table in the output file. When a range is selected the mole fractions of the specified components are summed and the total reported. For the first component or range of components to be tracked select the lower and upper limits through the combo boxes located next to the label Key Component 1. For the second key component or range select the lower and upper limits through the combo boxes located next to the label Key Component 2. The upper component must have a component index greater than or equal to the index for the lower component.
120 Compositional Grading
The thermal model data is specified on tab Thermal. To activate the thermal model check the box labelled Use Thermal Model. The temperature gradient imposed is constant and is entered in the textbox labelled Temperature Gradient. Entering a positive value for the thermal gradient implies increasing temperature with depth. The units are F/ft for field units or C/m for SI and modified SI. Various models for calculating the thermal diffusion coefficients can be selected. In addition, constant thermal diffusion coefficients terms for each component can be entered in the table labelled Thermal Diffusion Coefficient Terms. Note that values entered in this table are not the thermal diffusion coefficients usually defined in the literature, but are the terms identified as Ft in Hoier and Whitson (SPE 63085). This table can also be used to enter multiplying factors for each component which will multiply the thermal diffusion coefficients calculated from the chosen model. CMGs GEM compositional simulator allows input of tables of composition vs. depth for initialization of the reservoir via the keyword *ZDEPTH. The results of the compositional grading calculation can be written out with this keyword in the format expected by GEM. The data will be written to a file with the same root name as the data file and the extension (.gmz). This option is activated by selecting the check box labeled Write GEM *ZDEPTH keyword with composition vs. depth data .
Overview
You can use this option of WinProp to generate the complete PVT data required by CMGs steam and additives thermal simulator STARS. The data which may be generated includes: 1. Initial composition data 2. Liquid component densities, compressibility and thermal expansion coefficients, plus nonlinear mixing function data for density 3. Liquid component viscosity tables or correlation coefficients, plus nonlinear mixing function data for viscosity 4. Simple analytical correlation for component vapor-liquid K-values 5. Tabular gas-liquid K-values 6. Tabular liquid-liquid K-values 7. Tabular solid-liquid K-values 8. Gas-liquid and liquid-liquid K-values at surface conditions
Reference Conditions
Reference pressure and temperature corresponding to STARS keywords PRSR and TEMR are entered here. Based on small deviation from reference condition, perturbation method is used to obtain the compressibility and first/second thermal expansion coefficients required by the STARS liquid density model. Pressure-temperature cross coefficient for liquid density is obtained by density optimization method (see Density Optimization Range). The liquid density in STARS is equivalent to that given by WinProp at the reference state.
maximum pressure limits and the number of pressure steps can be input at the users option. A maximum of 40 steps for temperature or pressure may be specified.
Surface Conditions
Surface pressure and temperature corresponding to STARS keywords PSURF and TSURF are entered here. The STARS default for these values is 101 kPa and 16.85 C. The surface conditions are used for reporting well rates and accumulations in terms of standard densities. Values can be entered in the Pressure and Temperature text boxes, and a button is provided to reset the text boxes to the STARS default values.
either oleic or aqueous as the reference phase for each component (Tab: Henry Const. / Ref. Phase). If these check boxes are not selected, K-values will be determined from the correlations or tables. If K-value correlations are being used, the K-values at the surface temperature will be calculated from the correlations. If K-value tables are being used, surface K-values will be interpolated from the tables provided the surface conditions lie within the pressure and temperature range of the tables. If the surface conditions lie outside the range of the tables, the K-values corresponding to the pressure and temperature closest to the surface conditions will be used, that is the tables will not be extrapolated.
Pressure Data
The pressure data consists of an initial pressure, pressure step, and number of pressure steps. K-values are written out starting with the initial pressure, and continuing for the specified number of pressure steps, incrementing the pressure by the specified pressure step for each calculation. A maximum of 20 and a minimum of 2 pressure steps may be specified. The maximum number of table entries (number of pressure steps multiplied by the number of temperature steps) is 300.
126 STARS PVT Data Generation User's Guide WinProp
Temperature Data
The temperature data consists of an initial temperature, temperature step, and number of temperature steps. K-values are written out starting with the initial temperature, and continuing for the specified number of temperature steps, incrementing the temperature by the specified temperature step for each calculation. A maximum of 50 and a minimum of 2 temperature steps may be specified. The maximum number of table entries (number of pressure steps multiplied by the number of temperature steps) is 300.
aqueous, it is defined as the oleic phase mole fraction of the component divided by the aqueous phase mole fraction of the component. If the reference phase is oleic, it is defined as the aqueous phase mole fraction of the component divided by the oleic phase mole fraction of the component. Water is always defined as an aqueous component, thus the gas-liquid K-value is defined as the gas phase mole fraction of water divided by the aqueous phase mole fraction of water and the liquid-liquid K-value is defined as the oil phase mole fraction of water divided by the aqueous phase mole fraction of water. Generation of the gas-liquid and liquid-liquid K-value tables is done simultaneously using the Oil-Gas-Water flash, which models the aqueous phase with Henrys Law and the vapor and liquid phases with the equation of state. See the section on Flash Calculations for more details. If a stable oil-gas-water system exists at a specified pressure and temperature, all of the gas-liquid and liquid-liquid K-values are defined and may be calculated directly. If one or more of the three phases does not exist, a two-phase negative flash using Henrys Law for one phase is attempted. Following this flash, a split of the hydrocarbon phase is attempted using the negative flash with the EOS for both phases. At the end of this process, K-values for all of the phases which have been located are calculated, and the remaining K-values are extrapolated. As described under Gas-Liquid K-Value Tables, the map entitled Comparison of WinProp (W) and STARS K-value (S) phase split calculations is again generated. An additional phase indicator (A) indicating the aqueous phase is used. Differences between the WinProp and STARS K-value calculated results may exist for the reasons described in the section on Gas-Liquid K-Value Tables, and also because the step-wise two-phase negative flash procedure may give slightly different results than the simultaneous three-phase flash which is used as the basis for the WinProp phase split results. The only differences in input data as compared to the Gas-Liquid K-value Tables option are that Hands rule is not available as a composition-dependent K-value option and an additional water component option may be selected: Use WinProp calculated liquid-liquid K-values for water. This allows generation of a table for calculating the amount of water in the liquid hydrocarbon phase. The default is to not allow any partitioning of water into the oil phase.
Generation of the gas-liquid and solid-liquid K-value tables is done simultaneously using the Asphaltene/Wax Modelling method described in the Flash Calculations section. As for the Gas-Liquid and Solid-Liquid K-Value Tables, if a stable three-phase system exists at a specified pressure and temperature, all of the gas-liquid and solid-liquid K-values are defined and may be calculated directly. If one or more of the three phases does not exist, a two-phase negative flash using the solid model for one phase is attempted. Following this flash, a split of the hydrocarbon fluid phase is attempted using the negative flash with the EOS for both phases. At the end of this process, K-values for all of the phases which have been located are calculated, and the remaining K-values are extrapolated. As described under Gas-Liquid K-Value Tables, the map entitled Comparison of WinProp (W) and STARS K-value (S) phase split calculations is again generated. An additional phase indicator (S) indicating the solid phase is used. Differences between the WinProp and STARS K-value calculated results may exist for the reasons described in the section on GasLiquid K-Value Tables, and also because the step-wise two-phase negative flash procedure may give slightly different results than the simultaneous three-phase flash which is used as the basis for the WinProp phase split results. The only differences in input data as compared to the Gas-Liquid K-value Tables option are that Hands rule is not available as a composition-dependent K-value option and none of the water component options are enabled.
Process Flow
Overview
This option can simulate processes which may not conform to any of the standard laboratory options such as differential liberation or constant volume depletion. The user can use this option to custom design a plant or surface separation scheme. Keep in mind that no pressure drops are allowed between units and there are no heat losses between units. In addition, no recycling is allowed in the system. There are 6 different unit types to choose from. The table below summarizes the characteristics of each unit type. Unit type Max. # of inputs 1 1 10 10 10 1 Max. # of outputs 1 1 2 2 1 10 Quantity determined
Saturation pressure cell Saturation temperature cell Equilibrium cell Constant volume equilibrium cell Mixing cell Splitting cell
Saturation pressure Saturation temperature Vapor -liquid phase splits, compositions Vapor -liquid phase splits, compositions* Composition, flow rates Composition, flow rates
*For
the constant volume equilibrium cell the flow rates and the compositions of the vapor and liquid output streams are determined by the following procedure. The equilibrium compositions and volumes of the vapor and liquid phases are determined by the flash calculation. An amount of the vapor phase is purged so that the total volume of remaining vapor and liquid equals to the volume of the feed stream. The purged amount of the vapor phase is reported as the vapor phase flow rate. The remaining vapor and liquid phase in the cell is combined and reported as the output liquid phase composition and flow rate.
For the process units, four pieces of information are required in addition to the destination of the output streams: unit name, unit type, pressure and temperature. For the saturation pressure cell, the entered value of the pressure will be used as the initial guess for the saturation pressure. A good initial guess is required to ensure convergence. For the saturation temperature cell, the entered temperature will be used as the initial guess for the saturation temperature. Note that the user does not need to specify "output streams" explicitly. An "output stream" is defined as an exit stream from a unit that is not an inlet stream to another unit or to a product stream. These "output streams" are identified internally by the program. For input streams the required information is the unit name to which the stream is directed, the composition, flow rate, pressure and temperature. An input stream is defined as meeting two criteria simultaneously: (1) it is an inlet stream to a unit and (2) it is not an exit stream from some other unit in the calculation.
Tab Input Streams is used to add, delete or edit input streams. To define a new stream click on the Add button. The Stream name field will be filled with the string INSTR- followed by a number reflecting the total number of streams defined. The Stream name field cannot be edited by the user. The Composition field will show the default choice of PRIMARY. By default the Primary mole fraction field will show the value of 1.0 and be disabled. The primary composition entered on the most recently defined composition form is echoed on the composition grid. The composition grid is disabled for edits by default. The following table shows the ways in which the composition may be specified for an input stream and the controls involved.
Type
Status of primary Status of mole fraction text composition grid box Disabled Disabled
Composition entered as primary Select PRIMARY from the feed under the last composition composition drop down list form Composition entered as secondary feed under the last composition form Composition obtained by mixing primary and secondary feed compositions entered on the last composition form Select SECONDARY from the composition drop down list
Disabled
Disabled
Select MIXED from the composition drop down list. This will enable the primary mole fraction text box. Enter the mole fraction of the primary feed stream in this box Select USER INPUT from the composition drop down box. This will enable the composition grid. Enter values directly on this grid
Enabled
Disabled
Disabled
Enabled
Enter the flow rate, pressure and temperature in fields labeled Flow rate, Pressure and Temperature respectively. The flow rate can be specified on a molar or volumetric basis. The default is molar rates. Use the menu labeled Flow Units to select Molar or Volumetric basis. If SI units are being used then the molar rates should be kmol/time and volumetric rates in m3/time whereas for Field units the molar rates are in lb-mole/time and volumetric rates are in ft3/time. The final required piece of information is the name of the unit to which the input stream is directed. Enter the name of the unit or select from one of the units already defined through the drop down combo box labeled Input to. If the name of the unit is entered then this unit will be automatically created as a splitting unit. The user can set the properties of this unit subsequently by locating the appropriate record on tab 2, Process Units. To move between the defined input stream records click on the VCR type navigation arrows on the data control labeled Input Stream on the left bottom corner of the tab. The fields for a particular record can be edited by first loading the record via the data control and then entering new values on the corresponding text boxes such as flow rate etc. The changes will be saved by moving to a new record or by clicking on the OK button To delete an existing input stream use the data control to locate the record and then click on the Delete button. To save changes made on the tabs on the form press the OK button. The Cancel button will close the form without saving any of the changes.
Tab Process Units is for managing process units. To delete an existing unit use the VCR type navigation keys on the data control labeled Units to locate the desired unit and then click on the Delete button. Any Input to field of input streams referencing the deleted unit will be cleared to the null string. If the deleted unit was cited as the destination of one or more output streams from other unit(s) then those destination fields will be cleared to the empty string as well. To add a unit click on the Add button. This will result in a new record with the default name of UNIT- followed by a number representing the total number of units defined to that point. The unit type selected will be a SPLITTER by default. The Pressure and Temperature fields as well as destination fields will be left blank to be filled by the user. The user has one opportunity to edit the name field. Once the unit name text box is highlighted and then the focus lost the unit name cannot be edited. Alternatively, by moving to another record the unit name field cannot be edited subsequently. To enter the destinations of the output streams click on the button labelled Destinations. This will open an appropriate dialog box depending on the unit type. For a splitting unit, for example, there can be a maximum of 10 output streams. The user is required to enter the destination of each of these streams and the fraction of the total flow assigned to each stream. If the user enters a new unit name in the destination combo box then that unit is created automatically by the program. Tab Product Streams is for specifying the reporting conditions for predefined product streams such as OIL and GAS. There are 3 other predefined product streams in addition to OIL and GAS; these are named PR-STR3, PR-STR4 and PR-STR5. The user can reference any or all of these product streams in specifying the destination of an output stream from a particular unit. When a product stream is chosen as a destination, the corresponding record will be written to the data file. The block of keywords will be something like this:
*STREAM 'OIL' *PRESSURE 20.0 *TEMPERATURE 50.0
The user cannot delete or add a product stream record. The reporting conditions can be specified individually for a given product stream. Locate the appropriate product stream using the navigation arrows on the data control labeled Product Streams and edit the pressure or temperature values appearing in the respective text boxes.
Overview
This option can be used to generate the PVT data for simulation studies with CMGs blackoil simulator IMEX as well as other commercially available black-oil simulators. In the latter case, some of these simulators implement the Extended Black-Oil Formulation. In addition to the standard black-oil parameters an additional parameter, the condensate gas ratio, often denoted as Rv is added to account for oil component vaporization in the gas phase at reservoir conditions. WinProp can generate PVT data for the extended black-oil model. Unlike models for CMGs own simulator IMEX the data is presented in a generic format. The keywords do not exactly correspond to a specific simulator. The calculations should be done once an EOS model is obtained for the oil, generally through characterization of the heavy end followed by regression to match the available data. The PVT data is written out to a file with the root name corresponding to the input-data-file and with the extension (.imx). For example if the input file name is test.dat, the PVT data file will be test.imx. If the PVT data is designed for IMEX then it may be referenced as an include file in an IMEX data set or opened with ModelBuilder. If the PVT data is targeted at some other simulator then the information in the .imx file may require editing prior to use in the specific simulator of choice. A total of thirteen different fluid component models may be specified with IMEX. At present, WinProp can be used to generate six of those models, namely Black-Oil, Pseudomiscible with chase gas, Pseudo-miscible without chase gas, Gas-Water, Gas-Water with Condensate and Volatile Oil. Please refer to the IMEX user guide for more information on these fluid models. For PVT data aimed at one of IMEXs models, the following information is written out to the output file: 1. The *PVT *BG|*EG|*ZG 1 keyword and associated table (1 is always written out for the table number) are written for the oil models. The columns of this table are pressure, gas-oil ratio, oil formation volume factor, gas formation volume factor | gas expansion factor | gas Z-factor, oil viscosity and gas viscosity. For the pseudomiscible option with chase gas, the solution gas always remains in solution. The solution gas-oil ratio is fixed and input through a field on the Solvent tab (writes out keyword *GORINT). The bubble point pressure versus solution gas-oil ratio curve in the table belongs to the chase gas. This is NOT taken into account when values are written to the PVT table. The total amount of solution gas is the value
given by *GORINT and the dissolved chase gas given by the Rs vs. bubble point pressure curve. For the Gas-Water model, a *PVTG *BG|*EG|*ZG table is written. The columns of this table are pressure, gas formation volume factor | gas expansion factor | gas Z-factor and gas viscosity. For the Gas-Water with Condensate table, the *PVTCOND *BG|*EG|*ZG table is written with columns: pressure, gas-oil ratio, condensate-gas ratio, oil formation volume factor, gas formation volume factor | gas expansion factor | gas Z-factor, oil viscosity and gas viscosity. For this option, a series of *BGUST|*EGUST|*ZGUST and *VGUST tables are also written, giving the formation volume factor and viscosity of the gas at saturation pressures lower than the corresponding mixture pressures given in the *PVTCOND table. BOT tables are not generated for this option, as the oil is assumed to be saturated at all times. For the Volatile Oil option, either the PVTCOND or PVTVO table can be written. Using the PVTCOND table with associated *BGUST|*EGUST|*ZGUST and VGUST tables allows non-linear behavior of undersaturated gas to be modeled. Using PVTVO allows a simpler linear treatment of undersaturated gas properties by specifying only saturated gas and dry gas formation volume factors and viscosities. The *PVTCOND table specification is the same as for the Gas-Water with Condensate model, including use of *BGUST|*EGUST|*ZGUST and VGUST tables. The *PVTVO *BG|*EG|*ZG table is written with columns: pressure, gasoil ratio, condensate-gas ratio, oil formation volume factor, gas formation volume factor | gas expansion factor | gas Z-factor, oil viscosity, gas viscosity, dry gas formation volume factor | dry gas expansion factor | dry gas Z-factor and dry gas viscosity. *BOT tables are allowed with either table type for the volatile oil option. The units for these properties are indicated in the output file and are the same as in IMEX. Field, SI and modified SI units are supported. 2. Water phase properties are optional. The keywords written out are *REFPW, *BWI, *CW, *VWI, *CVW and *DENSITY *WATER. 3. Gas phase density at surface conditions, *DENSITY *GAS or *GRAVITY *GAS. 4. Oil phase density at surface conditions, *DENSITY *OIL. Pressure dependence of oil viscosity, *CVO. Oil compressibility at the original oil bubble point pressure *CO, or *BOT tables for the undersaturated oil may be output. Not required for the gas water option. 5. For the pseudo-miscible fluid models a *PVTS *BS table. The entries of the table are pressure, solvent water ratio, solvent expansion factor, solvent viscosity and mixing parameter between solvent and oil. The solvent density is written out with the keywords *DENSITY *SOLVENT. The mixing parameter between solvent and gas is written out with the *OMEGASG keyword. If the pseudo-miscible model with chase gas is chosen then the initial solution gas-oil ratio is written with keyword *GORINT.
To generate the PVT data for the IMEX black-oil model the following information is required: 1. Composition of oil and, if the swelling curve is to be generated, the gas composition. These are entered on the Composition form. Oil is entered as the primary fluid and gas is the secondary fluid. Note: For gas water option enter the gas composition as the primary fluid on the composition form. 2. The reservoir temperature and a guess for the saturation pressure of the original oil. These are entered on tab 2 of the Black-Oil PVT Data form. For gas water option only the reservoir temperature is required. 3. At least one pressure step for the differential liberation experiment on the grid with the label No. of pressure levels on tab 3, Pres. levels. For gas water option, these are pressures at which properties gas formation volume factor and gas viscosity are to be calculated. The differential liberation experiment is not performed for the gas water option. 4. The number of separators excluding the stock tank and the operating conditions on tab 3. A maximum of 8 separators may be specified. For gas water case only the standard (stock tank) conditions are required. 5. If the swelling curve is to be generated then the composition of the injection gas is entered on the Composition form as the secondary fluid. If the solution gas is to be used for swellling calculation, then select the appropriate option button on Tab 5, Gas Properties under the frame labelled injection gas composition for swelling test. On the grid labeled No. of swelling experiments on tab Pres. levels enter the mole fraction of the gas, initial guess for the saturation pressure of the oil/gas mixture and the saturation pressure flag. For gas water option these data are not required. 6. Water phase properties may be input by the user directly on tab 4 or alternatively estimated from built in correlations. This data is optional. 7. For the pseudo-miscible options the solvent composition can be the secondary fluid on the Composition form or values entered on tab Solvent properties. The oil solvent mixing ratio as a function of pressure is entered on the grid provided on this tab. These values are echoed as column 5 of the *PVTS table. The remaining entries of this table, that is the solvent water ratio, the solvent expansion factor and solvent viscosity will be calculated by the program. Note: add the water component from the library for the solvent solubility in the aqueous phase calculations. Enter a composition of zero for the water component. The fields for entering the solvent gas mixing parameter and the minimum solvent saturation are on tab Solvent properties. If the pseudo-miscible with chase gas option is selected then the initial solution gasoil ratio text box on this tab is enabled and a value is required. 8. For the Gas-Water with Condensate option, the method for calculating oil phase properties (Bo and GOR) must be selected on the Oil properties tab. Oil phase properties can be obtained by flashing a sample of the oil phase at each depletion pressure through the user defined separators (Method of Whitson and Torp) or alternatively from material balance equations (Method of Coats).
For PVT data aimed at an extended black-oil model, the following information is written out to the output file: 1. The *PVTO keyword and associated table. Typical output is shown below.
*PVTO ** solution pressure, oil oil ** GOR(2) psia FVF(1) vis,cp ** -----------------------------------------0.2606 515.00 1.2279 0.16615 1115.00 1.2158 0.17475 1915.00 1.1996 0.18621 2715.00 1.1834 0.19768 3515.00 1.1673 0.20914 5000.00 1.1372 0.23043 6034.82 1.1163 0.24526 6500.00 1.1069 0.25192 0.5045 1115.00 1.3730 0.14572 1915.00 1.3503 0.15714 2715.00 1.3275 0.16856 3515.00 1.3048 0.17998 5000.00 1.2626 0.20118 6034.82 1.2332 0.21595 6500.00 1.2199 0.22259 0.8261 1915.00 1.5462 0.12408 2715.00 1.5150 0.13452 3515.00 1.4839 0.14497 5000.00 1.4262 0.16436 6034.82 1.3859 0.17787 6500.00 1.3678 0.18394 1.1532 2715.00 1.7100 0.10950 3515.00 1.6720 0.11872 5000.00 1.6015 0.13582 6034.82 1.5523 0.14774 6500.00 1.5302 0.15310 1.4574 3515.00 1.8505 0.10135 5000.00 1.7735 0.11634 6034.82 1.7198 0.12679 6500.00 1.6956 0.13149 1.6255 5000.00 1.8713 0.10344 6034.82 1.8290 0.11189 6500.00 1.8100 0.11568 1.7044 6034.82 1.8751 0.10689 6500.00 1.8590 0.11031 1.7399 6500.00 1.8768 0.10845
Saturated
Saturated
Saturated
Saturated
Saturated
The columns of this table are the gas-oil ratio (GOR), pressure, oil formation volume factor, and oil viscosity. For each GOR value the first row shows the saturated fluid values. For a GOR of 0.186 mscf/stb for example, the saturation pressure is 515 psia, the formation volume factor equals 1.1689 and the viscosity is 0.16615 cP. Second and subsequent rows of data for a given GOR define the undersaturated curves for the oil formation volume factor and viscosity as a function of pressure as specified in column 2.
1. PVTG (gas phase properties) and associated table. Typical format is shown below:
*PVTG ** pressure, solution, gas gas ** psia CGR(4) FVF(3) vis,cp ** -----------------------------------------515.00 0.000597 5.73365 0.01262 0.000000 5.73597 0.01263 1115.00 0.001038 2.37473 0.01441 0.000597 2.37631 0.01441 0.000000 2.37845 0.01440 1915.00 0.005019 1.27344 0.01926 0.001038 1.28264 0.01905 0.000597 1.28366 0.01903 0.000000 1.28504 0.01900 2715.00 0.020711 0.90464 0.02658 0.005019 0.92026 0.02516 0.001038 0.92444 0.02481 0.000597 0.92491 0.02477 0.000000 0.92555 0.02472 3515.00 0.057092 0.75257 0.03598 0.020711 0.75975 0.03208 0.005019 0.76457 0.03045 0.001038 0.76597 0.03004 0.000597 0.76613 0.02999 0.000000 0.76634 0.02993 5000.00 0.186452 0.69119 0.06067 0.057092 0.64409 0.04474 0.020711 0.63417 0.04032 0.005019 0.63060 0.03844 0.001038 0.62977 0.03797 0.000597 0.62968 0.03792 0.000000 0.62956 0.03785 6034.82 0.265054 0.69762 0.07772 0.186452 0.66087 0.06746 0.057092 0.60205 0.05014 0.020711 0.58698 0.04532 0.005019 0.58085 0.04326 0.001038 0.57933 0.04274 0.000597 0.57916 0.04268 0.000000 0.57894 0.04261 6500.00 0.300389 0.70479 0.08562 0.265054 0.68800 0.08103 0.186452 0.64996 0.07045 0.057092 0.58755 0.05249 0.020711 0.57093 0.04747 0.005019 0.56402 0.04533 0.001038 0.56230 0.04479 0.000597 0.56210 0.04473 0.000000 0.56185 0.04464
Saturated Dry gas Saturated Under saturated Dry gas Saturated Under saturated Under saturated Dry gas Saturated Under saturated Under saturated Under saturated Dry gas Saturated Under saturated Under saturated Under saturated Under saturated Dry gas Saturated Under saturated Under saturated Under saturated Under saturated Under saturated Dry gas Saturated Under saturated Under saturated Under saturated Under saturated Under saturated Under saturated Dry gas Saturated Under saturated Under saturated Under saturated Under saturated Under saturated Under saturated Under saturated Dry gas
gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas gas
2. The columns of this table are the pressure, the condensate gas ratio, the gas formation volume factor and viscosity respectively. The first row corresponds to saturated values. Subsequent rows show the properties of the mixture of saturated gas and dry gas. These combinations are done such that the mixtures correspond to condensate gas ratios that are specified at lower pressures. For example at a pressure of 1800 psia there is one row for undersatured gas with a CGR of 0.00104 stb/mscf which is the CGR ratio at the previous pressure value of 1100 psia. 3. The stock tank densities of the oil, gas and water phase as well as the water phase properties. To generate the PVT data for the extended black-oil model the following information is required: 1. Composition of oil and, if the swelling curve is to be generated, the gas composition. These are entered on the Composition form. Oil is entered as the primary fluid and gas is the secondary fluid. The injection gas composition can alternatively be chosen to be the solution gas. The selection is made on Tab 5 Gas Properties. 2. Selection of the PVT Experiment. For black-oils, differential liberation corresponds the best to the depletion process occurring in the reservoir. For light oils differential liberation or constant volume depletion may be chosen. For gas condensates the constant volume depletion experiment is appropriate. The PVT experiment provides samples of the gas and oil phase which are then flashed through the user defined separators to obtain the oil and gas properties. This choice is made on Tab 1 of the Write BLACK-OIL PVT data form. 3. Selection of the method for calculating oil phase properties. Oil phase properties can be obtained by flashing a sample of the oil phase at each depletion pressure through the user defined separators (Method of Whitson and Torp) or alternatively from material balance equations (Method of Coats). This choice is made on Tab 1 of the form. 4. Option for calculating oil phase properties above the original saturation pressure. If values for the oil and gas properties are required for pressures greater than the original saturation pressure than a choice of three techniques is available. Option 1 is to simulate a swelling test to extend the curves. This requires the injection gas composition. This method generally works well for black-oils. Option 2 is to extrapolate the curves while honoring certain relationships between the parameters. For black-oils (but generally not for light oils and condensates) there is a linear relationship between oil phase formation volume and GOR. There is also a linear relationship between oil density and viscosity. Option 3 is to simply extrapolate the curves individually without assuming any specific relationship between the parameters. Option 3 appears to be the only viable option for light oils and gas condensates. 5. The reservoir temperature and a guess for the saturation pressure of the original oil. These are entered on tab 2 of the Black-Oil PVT Data form. 6. At least one pressure step for the differential liberation experiment or constant volume depletion experiment on the grid with the label No. of pressure levels on tab Pres. levels.
7. The number of separators excluding the stock tank and the operating conditions on tab 3. A maximum of 8 separators may be specified. 8. If the swelling curve is to be generated then the composition of the injection or solution gas is entered on the Composition form. On the grid labeled No. of swelling experiments on tab Pres. levels enter the mole fraction of the gas, initial guess for the saturation pressure of the oil/gas mixture and the saturation pressure flag. 9. Water phase properties may be input by the user directly on tab 4 or alternatively estimated from built in correlations. PVT data can also be generated for a commercial black oil simulator, not IMEX. This format is referred to as format 2, with format 1 corresponding to IMEX. There are four models in this case. Model 1 writes out differential liberation and separator calculation results separately, that is differential liberation data is not adjusted for surface (separator) conditions. Model 2 writes out the corrected differential liberation data. Model 3 is for simulating an oil water system. The differential liberation data is not corrected for surface conditions for model 3. Model 4 corresponds to a gas water system. PVT data for a black oil simulator written in format 2, the following information is written out to the output file: 1. The *BOTAB 1 keyword and associated table (1 is always written out for the table number) for models 1-3, including oil water and BGTAB 1 for gas water option. For models 1 and 2, this is followed DOS WTOS and PSAT keywords and the corresponding values. DOS is the density of saturated oil at reservoir temperature and the original oil saturation pressure in units of gm/cc. WTOS is the molecular weight of the oil in gm/gmol and PSAT is the saturation pressure of the original oil in psia or kPa units. For the oil water option, model 3, the BOTAB keyword is followed by DOB WTRO and GR keywords and the corresponding values in a new line. The values are the density of the residual oil from differential liberation experiment in gm/cc, molecular weight of the residual oil in gm/gmol and gas gravity of the solution gas. For the gas water option, model 4, the BGTAB keyword is followed by the GR keyword and a value for the gas gravity. Typical results for model 1 are shown below:
BOTAB 1 C** VALUES IN TABLE DIFLIB RESULTS, NOT CORRECTED FOR C** SURFACE CONDITIONS DOS WTOS PSAT 0.5897 99.48 2179.86
2. The columns of the BOTAB table for models 1 and 2, are the saturation pressure, gas-oil ratio, oil formation volume factor, gas formation volume factor, gas gravity, oil viscosity and gas viscosity. The table is arranged with highest pressure first and the lowest pressure last in monotonic order. The units for these properties are indicated in the output file. For model 1 where the entries in the BOTAB table are not adjusted for surface conditions, the values shown correspond to those calculated by the differential liberation test. For model 2 the values in the table have been corrected for surface conditions. For model 3, Oil Water option, the values in the BOTAB have not been adjusted for surface conditions. Since gas properties are not required the columns of the oil water table are saturation pressure, gas oil ratio, oil formation volume factor and oil viscosity. The columns of the BGTAB table are the pressure, gas formation volume factor and gas viscosity. Typical results for model 1 are shown below:
User's Guide WinProp Black-Oil PVT Data Generation 141
C** pressure, solution oil gas gas oil gas C** psia GOR(2) FVF(1) FVF(3) gravity vis,cp vis,cp C** -------------------------------------------------------------------PSAT RS BO BG GR VO VG 3970.15 1.5087 1.8045 0.74298 0.85325 0.20414 0.0303 3726.70 1.3440 1.7254 0.78048 0.83804 0.22407 0.0283 2872.26 0.8910 1.5086 0.98604 0.79643 0.30972 0.0224 2179.86 0.6192 1.3788 1.30766 0.77723 0.40449 0.0189 2100.00 0.5915 1.3651 1.35951 0.77610 0.41726 0.0186 1850.00 0.5094 1.3242 1.55392 0.77425 0.46041 0.0177 1600.00 0.4334 1.2864 1.81437 0.77564 0.50903 0.0168 1350.00 0.3625 1.2510 2.17750 0.78143 0.56684 0.0160 1100.00 0.2959 1.2174 2.71317 0.79374 0.61839 0.0154 850.00 0.2325 1.1851 3.57349 0.81701 0.67266 0.0147 600.00 0.1707 1.1528 5.16455 0.86209 0.74204 0.0141
3. For models 1-3 the undersaturated oil formation volume factors and oil viscosities curves as a function of pressure for each saturation pressure. These are defined by a table with columns corresponding to saturation pressures as shown on the BOTAB table and rows corresponding to pressure elevation above the saturation pressure i.e. dp = p-psat. For each pressure a value for the formation volume factor and a value for the oil viscosity divided by the corresponding values at saturation pressure is shown. Typical results are shown below:
PSAT 3970.15 3726.70 2872.26 2179.86 1350.00 1100.00 850.00 600.00 2100.00 1850.00 1600.00
DP BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC BOFAC VOFAC 243.44 0.9921 1.02010 0.9925 1.02042 0.9937 1.02213 0.9945 1.02421 0.9946 1.02449 0.9949 1.02541 0.9952 1.02642 0.9954 1.03114 0.9957 1.03619 0.9960 1.03787 0.9963 1.03973 1097.89 1.10918 1.14044 1790.29 1.17804 1.22902 1870.15 1.18598 1.23923 2120.15 1.21084 1.27121 0.9645 0.9757 0.9807 0.9422 0.9604 0.9685 0.9396 0.9586 0.9670 0.9315 0.9531 0.9626 1.09065 1.11044 1.16320 1.14781 1.18009 1.26613 1.15441 1.18812 1.27800 1.17505 1.21327 1.31517 0.9662 0.9770 0.9819 0.9448 0.9624 0.9704 0.9424 0.9608 0.9691 0.9347 0.9555 0.9650 1.09209 1.11461 1.17077 1.15017 1.18688 1.27847 1.15686 1.19522 1.29089 1.17783 1.22132 1.32978 0.9714 0.9782 0.9831 0.9534 0.9645 0.9725 0.9513 0.9629 0.9713 0.9448 0.9579 0.9674 1.09979 1.11914 1.17917 1.16273 1.19428 1.29216 1.16999 1.20294 1.30519 1.19271 1.23007 1.34599 0.9753 0.9794 0.9597 0.9665 0.9579 0.9650 0.9523 0.9603
2370.15 1.23571 1.30319 2620.15 1.26057 1.33518 2870.15 1.28543 1.36716 3120.15 1.31029 1.39914 0.8911 0.9254 0.9406
0.9234 0.9475 0.9582 0.9154 0.9420 0.9538 0.9073 0.9365 0.9494 0.8992 0.9309 0.9450 1.27825 1.33901 1.50098
1.19569 1.23842 1.35233 1.21633 1.26356 1.38949 1.23697 1.28871 1.42666 1.25761 1.31386 1.46382 0.8962 0.9293 0.9444
0.9270 0.9503 0.9609 0.9193 0.9450 0.9568 0.9116 0.9398 0.9526 0.9039 0.9345 0.9485 1.28268 1.35180 1.52421
1.19880 1.24741 1.36866 1.21977 1.27351 1.40755 1.24074 1.29961 1.44643 1.26171 1.32570 1.48532 0.9123 0.9331 0.9483
0.9383 0.9530 0.9636 0.9318 0.9480 0.9598 0.9253 0.9430 0.9559 0.9188 0.9381 0.9521 1.30633 1.36572 1.54998
1.21543 1.25720 1.38679 1.23816 1.28433 1.42759 1.26088 1.31146 1.46838 1.28360 1.33859 1.50918 0.9242 0.9369
0.9467 0.9556 0.9410 0.9509 0.9354 0.9462 0.9298 0.9416 1.33515 1.43112
4. For options 1 and 3 the oil properties of the original oil as calculated by flashing through the user defined separator battery. Typical output is shown below:
C** SEPARATOR TEST DATA SEPTEST 1 PVTTABLE 1 PSATF BOF 2179.86 1.3447 P T GOR 300.00 75.00 0.42 200.00 75.00 0.03 100.00 75.00 0.04 14.70 60.00 0.08
To generate the PVT data for the black-oil model, format 2, the following information is required: 1. Composition of oil and, if the swelling curve is to be generated, the gas composition. These are entered on the Composition form. Oil is entered as the primary fluid and gas is the secondary fluid. Alternatively the user can choose to use the solution gas at the original oil saturation pressure as the injection gas. This option can be selected from tab 5, Gas Properties under the frame injection gas composition for swelling test. For gas water option enter the gas composition as the primary fluid on the composition form. 2. The reservoir temperature and a guess for the saturation pressure of the original oil. These are entered on tab 2 of the Black-Oil PVT Data form. For gas water option only the reservoir temperature is required. 3. At least one pressure step for the differential liberation experiment on the grid with the label No. of pressure levels on tab Pres. levels. 4. The number of separators excluding the stock tank and the operating conditions on tab 3. A maximum of 8 separators may be specified. 5. If the swelling curve is to be generated then the composition of the injection or solution gas is entered on the Composition form. On the grid labeled No. of swelling experiments on tab Pres. levels enter the mole fraction of the gas, initial guess for the saturation pressure of the oil/gas mixture and the saturation pressure flag. For gas water option these data are not required.
User's Guide WinProp Black-Oil PVT Data Generation 143
6. Water phase properties may be input by the user directly on tab 4 or alternatively estimated from built in correlations.
Laboratory Procedure
This procedure is generally performed to obtain PVT data for black-oil simulation. The sample of reservoir liquid in the laboratory cell is brought to the bubble-point pressure, and the temperature is set to the reservoir temperature. Pressure is reduced by increasing the cell volume. All the gas is expelled from the cell while pressure is held constant by reducing the cell volume. The gas is collected and its composition and volume are measured at the experiment conditions as well as standard conditions. This enables the formation volume factor of gas (Bg) to be calculated. The gas viscosity is also measured. A sample of the oil phase is removed at each pressure and its viscosity is measured. The oil sample is then flashed through the separators to obtain the formation volume factor and gas-oil ratio. The process is repeated in steps until atmospheric pressure is reached. For the light oil model the gas sample at each step is also put through the separators to obtain the gas shrinkage as well as condensate production at the surface. To obtain data corresponding to the swelling curve the procedure for the swelling experiment is followed to obtain the saturation pressure. The reservoir oil is loaded in a cell, and the temperature is set at the reservoir temperature. The bubble point of the oil is measured. A small amount of injection gas is transferred into the cell. A new saturation pressure is determined. This process is repeated until the upper bound of injection-gas concentration is reached (e.g. 60 mol %) or the saturation pressure of the fluid is equal to the estimated injection pressure. Each oil/gas mixture is then flashed through the separators to get the oil formation volume factor and GOR. In addition the properties of the equilibrium gas is measured and reported (gas formation volume factor, viscosity).
Input Data
This option is invoked by selecting Simulator PVT|Black-Oil PVT Data or by clicking on the options toolbar button BLK PVT. The template files imex-blackoil.dat, imex_condensate.dat and imex_voloil.dat show the data entry for all of the supported fluid models for IMEX. Normally only a single Black-Oil PVT Data form should be included in a data set. There are also two additional template cases, extended_blackoil.dat illustrating generation of PVT data for an extended black oil model and format2_blackoil.dat for black oil model with the results written out in format type 2. On tab Model select either CMG IMEX PVT Models, Extended Black-Oil PVT models or Black Oil PVT Model (format II). If IMEX PVT model is chosen then select further one the six available fluid models, for Black Oil PVT Model (format II), choose one of the four available models. Then enter data on Tabs Sat. Pressure, Pres. Levels, Water properties (optional), Oil properties and Gas properties. The Solvent properties tab is also enabled for data entry if one of the pseudomiscible fluid models of IMEX is selected. For Extended Black-Oil PVT models select the Experiment Type and the method of calculating oil properties, one of either WhitsonTorp or Coats. Selection of Whitson-Torp implies oil phase properties are calculated by flashing a sample of the oil phase at each pressure step of the differential liberation, constant volume depletion or swelling test simulation. By selecting Coats, oil phase properties are calculated by material balance principles where possible, that is, for pressures less than the
144 Black-Oil PVT Data Generation User's Guide WinProp
original oil saturation pressure. If data for pressures greater than original oil saturation pressure is required then select the method for generating this data. There are three choices here: Swelling experiment, Extrapolation assuming relationship between parameters and straight extrapolation of each individual property. For a description of the data on Tab Sat. Pressure, please refer to the section entitled Saturation Pressure. On Tab Pres. Levels, enter the pressure levels for the differential liberation calculation underneath the label No. of pressure levels. These pressures should all be less than the saturation pressure if the swelling option is being used to generate data for pressures greater than the original oil saturation pressure. If the extrapolation option is being used enter all pressures in the differential liberation table including pressures greater than the original oil saturation pressure. Enter values starting from the highest pressure value to the lowest pressure value. As values are entered the caption No. of pressure levels will be updated accordingly. Rows can be added or deleted from this table by invoking the Table item on the menu. At least one value is required. The pressure and temperature for the separator stages can be defined in the frame labeled Separator conditions. A maximum of eight separator stages excluding the stock tank is allowed. The stock tank pressure is entered in the text box labeled Stock tank pressure and the stock tank temperature in the text box labeled Stock tank temperature. The stock tank stage is always included in the calculation whereas the inclusion of other separators is optional. The separator pressure and temperature are entered directly on the table. Please enter values starting from the highest pressure to the lowest pressure on the table. If there is only one separator then the pressure and temperature for this separator should be entered on row 1. For two separators use the first two rows. If the swelling curve is to be generated then enter the mole fraction of the gas in column 2 of the table labeled No. of swelling experiments. On column 3 enter the initial guess for the saturation pressure of this mixture and column 4 enter the saturation pressure flag. Valid entries here are either 2 or 2. A value of 2 indicates that the initial guess for saturation pressure will be improved via stability analysis, while a value of 2 indicates that the initial guess entered on the table will be used directly. The tab Pressure levels corresponding to imex-blackoil.dat is shown below:
On Tab Water properties enter the properties of the water phase. These may be input directly by the user or calculated from internal correlations by the program. To calculate from correlations enter data for salinity, water bubble point and the reference pressure, then click the Apply:... button at the bottom of the form. Alternatively, data can be entered directly in the required fields reference pressure, formation volume factor of the water, compressibility, viscosity at the reference pressure, pressure dependence of viscosity and water phase density. On Tab Oil properties, the user can enter values of certain oil properties directly instead of accepting the values calculated internally by WinProp. To enter oil density (or alternatively oil gravity) directly, select that option from the group of buttons under the Oil density / API gravity frame and enter the value in the text box provided. To enter the oil viscosity pressure dependence directly select Input oil viscosity pressure dependence and enter a value for this property in the text box. For the undersaturated oil compressibility three options are available. The default is to create a table of undersaturated compressibility as a function of saturation pressure. Alternatively if only the compressibility of oil corresponding to the original oil composition at the saturation pressure is desired then select Calculate undersaturated oil compr. at the oil B.P pres. To enter the oil compressibility of the original oil at saturation pressure select Input undersaturated oil compr. at the oil B.P pres. and enter an appropriate value in the text box provided. On Tab Gas Properties, various options for writing out the gas phase density or specific gravity are provided. The user can either accept the WinProp generated value or enter the appropriate value directly.
If one of the two pseudo-miscible models is selected than additional data is required on Tab Solvent properties. This includes the solvent composition, gas-oil mixing ratio as a function of pressure, the solvent gas mixing ratio, the minimum solvent saturation and for the pseudomiscible fluid model with chase gas the initial gas-oil ratio. Extended black-oil model: Coats Material Balance equations In the Coats method, only the reservoir vapor is taken through the separators. The oil phase properties formation volume factor (Bo) and gas-oil ratio (Rs), are obtained from material balance equations at each expansion step of the CVD or differential liberation experiment from V1 to V2. These equations are:
sto V2 b g S g + b o R sS o
Where sto and stg are fixed surface densities and bo = 1/Bo, bg = 1/Bg. The stock tank densities are obtained from the output of the separators at saturation pressure. The values at the saturation pressure are obtained by the Whitson-Torp method. Compressibility test Oil and gas properties calculated for IMEX or for the extended black-oil simulator are checked to ensure that the total compressibility is greater than zero. This requires that the oil and gas compressibilities (Co and Cg) respectively as defined by the following equations are greater than zero:
C0 = Cg = 1 dB o dR s B g R v Bo + B0 dp dp (1 R s R v ) 1 dB g dR v B0 R s B g + Bg dp dp (1 R s R v )
References
List
1. Ahmed, T.: Hydrocarbon Phase Behavior, Gulf Publishing Company, Houston, 1989. 2. Agarwal, R.K., Li, Y.-K., and Nghiem, L.: "A Regression Technique With Dynamic Parameter Selection for Phase-Behavior Matching", SPE Reservoir Engineering, February 1990, pp. 115-120. 3. Danesh, Ali: Developments in Petroleum Science 47, PVT and Phase Behaviour of Petroleum Reservoir Fluids, Elsevier, 1998. 4. Dranchuk, P.M., Purvis R.A., and Robinson D.B.: "Computer Calculations of Natural Gas Compressibility Using the Standing and Katz Correlation", Institute of Petroleum Technical Series, No IP 74-008, 1974. 5. Firoozabadi, A., Katz, D.L., Soroosh, H., and Sajjadian, V.A.: "Surface Tension of Reservoir Crude-Oil-Gas Systems Recognizing the Asphalt in the Heavy Fraction", SPE Reservoir Engineering, February 1988, pp. 265-272. 6. Grabowski, M.S., and Daubert, T.W.: "A Modified Soave Equation of State for Phase Equilibrium Calculations", I. & E.C. Process Design and Development, Vol. 17, No. 4, 1978, pp. 443-454. 7. Goossens, A.G.: "Prediction of Molecular Weight of Petroleum Fractions", Ind. Eng. Chem. Res., 35, 1996, pp. 985-988. 8. Heidemann, R.A., and Khalil, A.M.: "The calculation of Critical Points", AIChE J., Vol. 26, September 1980, pp. 769-779. 9. Hoffman, A.E., Crump, J.S., and Hocott, C.R.: "Equilibrium Constants for a Gas Condensate System", Trans. AIME, 198, pp. 1-10, 1953. 10. Jhaveri, B.S., and Youngren, G.K.: "Three-Parameter Modification to the PengRobinson Equation of State to Improve Volumetric Predictions", SPE Reservoir Engineering, Vol. 3, No. 3, August 1988, pp. 1033-1040. 11. Katz, D.L., and Firoozabadi, A.: "Predicting Phase Behavior of Condensate/Crude-Oil Systems Using Methane Interaction Coefficients", J. Petrol. Technol., Vol. 30, November 1978, pp. 1649-1655. 12. Kesler, M.G., and Lee, B.I.: "Improve Prediction of Enthalpy of Fractions", Hydro. Proc., March 1976, pp. 153-158.
References 149
13. Kokal, S.L., and Sayegh, S.G.: "Gas-saturated bitumen density predictions using the volume-translated Peng-Robinson equation of state", Journal of Canadian Petroleum Technology, Vol. 29, No. 5, September-October 1990, pp. 77-82. 14. Lee, A.L., and Eakin, B.E.: "Gas-Phase Viscosity of Hydrocarbon Mixtures", Society of Petroleum Engineers Journal, Vol. 4, September 1964, pp. 247-249. 15. Lee, B.I., and Kesler, M.G.: "A Generalized Thermodynamic Correlation Based on Three-Parameter Corresponding States", AIChE J., Vol. 21, May 1975, pp. 510-527. 16. Li, Y.-K., Nghiem, L.X.: "Phase Equilibria of Oil, Gas and Water/Brine Mixtures from a Cubic Equation of State and Henry's Law", Can. J. Chem. Eng., Vol. 64, 1986. 17. McCain, W.D. Jr.: The Properties of Petroleum Fluids, Second Edition, PennWell Books, Tulsa, Oklahoma, 1990. 18. Merrill, R.: EEC Summer School 1993; Sampling and Characterization of Reservoir Fluids, Course Notes, 1993. 19. Nghiem, L.X., Hassam, M.S., Nutakki, R., and George, A.E.D.: "Efficient Modeling of Asphaltene Precipitation", paper SPE 26642, presented at the 68th Annual Technical Conference and Exhibition of SPE, Houston, Texas, 3-6 October 1993. 20. Nghiem, L.X., Coombe, D.A., and Hassam, M.S.: "Modelling effects on Asphaltene Precipitation", Hydrocarbon Technology International, Autumn 1996. 21. Nghiem, L.X., and Li, Y.-K.: "Computation of Multiphase Equilibrium Phenomena With an Equation of State", Fluid Phase Equilibria, Vol. 17, 1984, pp. 77-95. 22. Nghiem, L.X., Li, Y.-K., and Heidemann, R.A.: "Application of the Tangent Plane Criterion to Saturation Pressure and Temperature Computations", Fluid Phase Equilibria, Vol. 21, 1985, pp. 39-60. 23. Nghiem, L.X., and Li, Y.-K.: "Phase-Equilibrium Calculations for Reservoir Engineering and Compositional Simulation", Proceedings of the Second International Forum on Reservoir Simulation, Alpbach, Austria, September 4-8, 1989. 24. Nutakki, R., Nghiem, L., Li, Y.-K., and George, A.: "Optimal Representation of Heavy Fractions in the Simulation of Multiple-Contact Processes", paper CIM/AOSTRA 91-57, presented at the 1991 CIM/AOSTRA Technical Conference, Banff, April 21-24. 25. Nutakki, R., Hamoodi, A.N., Li, Y.-K., and Nghiem, L.X.: "Experimental Analysis, Modelling, and Interpretation of Recovery Mechanisms in Enriched-Gas Processes", paper SPE 22634, presented at the 66th Annual Technical Conference and Exhibition of SPE, Dallas, Texas, 6-9 October 1993. 26. Oellrich, L., Plocker, U., Prausnitz, J.M., and Knapp, H.: "Equation-of-State Methods for Computing Phase Equilibria and Enthalpies", Int. Chem. Eng., Vol. 21, No. 1, January 1981, pp. 1-15. 27. Pedersen, K.S.: Energy and Fuels, v. 5, pp. 924, 1991. 28. Pedersen, K.S., and Fredenslund, Aa.: "An improved corresponding states model for the prediction of oil and gas viscosities and thermal conductivities", Chemical Engineering Science, Vol. 42, No. 1, pp. 182-186, 1987.
150 References User's Guide WinProp
29. Pedersen, K.S., Fredenslund, Aa., Christensen, P.L., and Thomassen, P.: "Viscosity of Crude Oils", Chemical Engineering Science, Vol. 39, No. 6, pp. 1011-1016, 1984. 30. Pedersen, K.S., Fredenslund, Aa., and Thomassen, P.: Properties of Oils and Natural Gases, Gulf Publishing Company, Houston, Texas, 1989. 31. Peneloux, A., Rauzy, E., and Freze, R.: "A Consistent Correction for RedlichKwong-Soave Volumes", Fluid Phase Equilibria, Vol. 8, 1982, pp. 7-23. 32. Peng, D.-Y., and Robinson, D.B.: "A New Two-Constant Equation of State", Ind. Eng. Chem. Fundam., Vol. 15, 1976, pp. 59-64. 33. Reid, R.C., Prausnitz, J.M., and Sherwood, T.K.: The Properties of Gases and Liquids, 3rd Edition, McGraw-Hill, New York, 1977. 34. Riazi, M.R., and Daubert, T.E.: "Simplify Property Predictions", Hydro. Proc., March 1980, pp. 115-116. 35. Sandler, S.I.: Chemical and Engineering Thermodynamics, John Wiley and Sons, New York, 1977. 36. Twu, C.H.: "An Internally Consistent Correlation for Predicting the Critical Properties and Molecular Weights for Petroleum and Coal-Tar Liquids", Fluid Phase Equilibria, Vol. 16, 1984, pp. 137-150. 37. Walas, S.M.: Phase Equilibria in Chemical Engineering, Butterworth Publishers, Boston, 1985. 38. Whitson, C.H.: "Characterizing Hydrocarbon Plus Fractions", Society of Petroleum Engineers Journal, August, 1983, pp. 683-694. 39. Whitson, C.H. and Belery, P.: "Compositional Gradients in Petroleum Reservoirs", SPE 28000, University of Tulsa Centennial Petroleum Engineering Symposium, Tulsa, OK, Aug 29-31, 1994. 40. Whitson, C.H., Anderson T.F., and Soreide I.: "C7+ Characterization of Related Equilibrium Fluid Using the Gamma Distribution", paper in "C7+ Characterization", Edited by Mansoori, Chorn, Taylor and Francis, New York, 1989. 41. Whitson, C.H., and Torp, S.B.: "Evaluating Constant Volume Depletion Data", SPE 10067, JPT, March 1983, pp. 610-620. 42. Wichert, E and Aziz, K.: "Calculate Zs for Sour Gas Hydrocarbon Processing", Vol. 51, pp. 119, May 1972. 43. Won, K.W.: "Thermodynamics for Solid-Liquid Equilibria: Wax Formation from Heavy Hydrocarbon Mixtures", Fluid Phase Equilibria, Vol. 30, 1986, pp. 265-279. 44. Zick, A.A.: "A Combined Condensing/Vaporizing Mechanism in the Displacement of Oil by Enriched Gases", SPE 15493, Proc. of 61st Ann. Conf., Oct 1996.
References 151
Appendix A
Case Studies
Introduction The case studies presented in this section are designed to guide the user step-by-step through practical phase behavior modelling problems. Case Study Number 1 describes in detail the steps involved in heavy fraction characterization and equation of state tuning for a gas condensate. Working through this case study will provide practice in techniques for data set editing, the component properties updating procedure, data specification for a number of calculation options, as well as possible methods to use in your own regression problems. Case Study Number 2 illustrates the use of the Oil-Gas-Water flash for predicting solubility of gases in brine and regression on the aqueous phase solubility parameters. Generation of the required equation of state parameters to define the fluid model for CMGs GEM compositional simulator is also shown. Case Study Number 3 shows how to develop a model for predicting precipitation of asphaltene from a black oil under pressure depletion.
Set EOS Model and Unit System Double-clicking on the row labelled Titles/EOS/Units opens the form for selecting the EOS model and units system. Text to appear on the main form for the data set can be typed in the text box labelled Comments, while text to appear in the output file can be entered into the text boxes labelled Title 1 - 3. The text from Title 1 will also be used to label any plots that are created. The EOS and Units selection may be left at the default values as shown below.
Specify System Components to C6 Click OK to accept the data on the form and return to the main WinProp form. Specification of the system components is done by double-clicking on the row labelled Component Selection/Properties. In this case all components up to hexane may be selected from the WinProp component library. From the Component Selection/Properties form menu, select Options|Insert library component and then use the mouse to choose the system components as shown on the form below.
154 Appendix A
Again, click OK to accept the selection and return to the Component definition form. All other information on this form can be left at the default values. Please refer to the Components section for information on modifying any of the default component properties. Click OK to return to the main form. Specify System Composition Composition for the selected components is specified by double-clicking on the row labelled Composition and entering the values in mole % as shown on the following form.
A message will be issued when this form is closed, warning that the composition does not sum to 1 or 100. Since the heptane plus fraction has not yet been included in the system, this warning can safely be ignored.
Appendix A 155
Specify C7+ Fraction Properties Now that all of the light and intermediate components have been defined, all that remains is to characterize the heavy fraction as several pseudo-components. Specification of the heavy fraction properties, splitting into single carbon number fractions, and lumping into pseudo-components is easily done in a single step with WinProps splitting option. From the main form, open the Plus Fraction Splitting form and enter the plus fraction properties on the third tab as shown below.
Specify Plus Fraction Splitting and Lumping Calculation Now, click on the General tab to view the default parameters to be used for the splitting and lumping calculations. The plus fraction will first be split into 25 single carbon number fractions. Select Lee-Kesler as the critical property correlation to be used to generate the properties of these fractions. By default, WinProp will automatically determine the number of pseudo-components to lump into. It is also possible to select no lumping, or the user can enter the desired number of pseudo-components. The mole fraction of the component immediately preceding the plus fraction also has to be entered on tab 2, Distribution. In our case the component is FC6 with mole fraction equal to 0.0173. Information on the other tabs can be found in the Component splitting and lumping section. Click OK to return to the main form. Save the Data Set and Run the Splitting Calculation The splitting calculation is now ready to run. Select File|Save and enter a file name. The file extension (.DAT) will be added automatically if it is not specified. Now select File|Run to run the data set. When control returns to WinProp, the output file can be viewed by selecting File|View output. The distribution of single carbon number fractions and the final properties of the lumped components are shown in the output file.
156 Appendix A
Update the System Component Specification The next step in the tuning process is to match the available experimental data via regression. First, the component specification must be updated to reflect the results of the splitting calculation. This is done by selecting File|Update component properties from the main menu, which will modify the first three forms in the data set. Open the Titles/EOS/Units form and enter a new comment and descriptive title for this data set. On the Component Selection/Properties form the properties of the full component specification, including the heavy pseudo-components, can be viewed and a new comment entered. Open the Composition form to verify that the mole fractions now sum to one. At this point the splitting calculation can be removed from the data set by selecting the row labelled Plus Fraction Splitting on the main form and pressing the Delete key or selecting Edit|Delete from the main menu. To avoid overwriting the original data set, select File|Save As and enter a new name for the data set. Set Up the Regression Data Set To begin setting up the regression run, make sure the row directly under the row labelled composition is selected. From the main menu select Regression|Start. The data set should now look like the following:
Copy the Data for Regression The saturation pressure, constant composition expansion and constant volume depletion specification experimental data can now be copied from the template file Case_study-1.dat. This file is located in the WinProp templates directory, for example cmg\WinProp\1999.10\Tpl. Open the Case_study-1.dat data file, and select the rows from Saturation Pressure through Constant Volume Depletion using the mouse. The WinProp window should appear as follows:
Appendix A 157
Select Edit|Copy from the main menu to copy these calculation options to the clipboard. Close the Case_study-1.dat file, then make sure that the row directly underneath Regression Parameters in your data file is selected and choose Edit|Paste to paste the contents of the clipboard into your data file. Next, click on the row underneath Constant Volume Depletion, then select Regression|End to indicate the end of the calculation options to be included in the regression. View the calculation specifications and experimental data by double-clicking on the appropriate row. Select Initial Regression Parameters The parameters to be used in the regression can now be selected by double-clicking on the Regression Parameters row. To begin, select the critical pressures of the C7+ pseudocomponents as regression variables. This is done by clicking on the cells in the first column (labelled Pc) for the last 5 components in the system. The first tab on the Regression Parameters form should now look like the following:
158 Appendix A
Click on the tab labelled Interaction Coefficients and in the same manner as for the critical pressures, select the Hydrocarbon Interaction Coefficient Exponent and the interaction coefficients between CO2 and Methane, and between CO2 and the C7+ pseudo-components. Select OK. Before the Regression Parameters form closes, a message box appears asking if you would like to change the value for the number of simultaneous regression parameters. Click No to accept the default value of 5. This means that a subset of the 5 most sensitive regression parameters will be used at each regression iteration. For more details please refer to the Regression section of the manual. Run the Regression Data Set The regression data set is now ready to run. Select File|Run; since the data set has changed since it was last saved, a message box appears asking if you would like to save the data set before running. Click Yes to save your changes. While the data set is running, the progress of the regression can be tracked by noting the values of the residuals in the window displaying the run status messages. This information is also echoed to the output file. It is important to note that the magnitude of the change from the initial value of the residual is more important than the values of the residuals themselves. Create Regression Summary Plots Summary plots of the before regression and after regression results, along with the experimental data, can be created by selecting File|Create Excel plots from the main menu. This will create an Excel workbook with individual plots of all of the simulated results, as well as the summary plots. Viewing the summary plots for this run quickly shows that only minimal improvement in the fit was obtained. Note particularly that the liquid dropout values for the constant volume depletion have large errors. Check the Regression Summary Table To check the numerical values for the before and after regression calculation errors, open the output file by selecting File|View output from the main menu. At the end of this file is a table with a summary of the regression results. Check if there has been any improvement of the match to the saturation pressure, shown in the first row of the summary table. Modify the Regression Specification Modifications to the data set can now be made to improve the predictions of the volumetric data and the saturation pressure. Begin by opening the Component Selection/Properties form and viewing the column for the Volume Shift parameters. Note that all components have a default volume shift of zero. Select Volume Shift|Reset to correlation values from the menu to insert values correlated with component molecular weight for all components. Next, open the Saturation Pressure form, and on the tab Calculations, enter a value of 50.0 for the weight associated with the experimental saturation pressure value. This is to ensure that the saturation pressure is more closely matched. On the Constant Volume Depletion form, Pressure Levels tab, enter a weight of 5.0 for the liquid dropout values. Now, open the Regression Parameters form and add the volume shift parameters for methane and the C7+ pseudo-components as regression variables.
Appendix A 159
Run the Modified Regression Data Set Save and run the data set again. Note the decrease in the residual values. Create the Excel plots again. Check the match to the liquid dropout on the CVD summary plot. View the summary table in the output file to observe the effect of increasing the weight for the saturation pressure experimental data. Specify Group Variables for Regression Further improvement of the fit can be attempted using WinProps regression variable grouping method. The grouping method ensures that existing trends in the original component properties are maintained, by incrementing or decrementing all of the members of a group by the same amount during regression. Since each group is treated as a single regression variable, this also provides a method for varying a large number of component properties without having to select them all as individual regression parameters. Open the Regression Parameters form, and clear the selection of the critical pressures and volume shifts for the components C07-C09 through C15-C17 by clicking on the cells marked with an X for those components. Leave Pc and Vol shift selected for component C18+, and then select critical temperature and acentric factor for C18+. From the menu, select Grouping|Start group selection, then click on the cells for components C07-C09 through C15C17 in the critical pressure column then select Grouping|End group selection from the menu. In the same manner, select regression variable groups for the components C07-C09 through C15-C17 for properties: critical temperature, acentric factor and volume shift. On completion, the form should appear as follows:
The interaction coefficients can be left as they were selected for the last run.
160 Appendix A
Run the Data Set and Create Final Summary Plots Save and run the data set with the new regression specification. In this case, the residual is reduced significantly, indicating that a much better fit has been obtained. Check the output file to verify that the predicted saturation pressure now matches the experimental value quite closely. Create the Excel plots and view the regression summary plots. The CVD summary should now show a good match of the liquid dropout as shown below.
CVD pressure levels and depletion data : CVD Calc. Regression Summary
35.0 30.0 Liquid Volume, % original vol. 25.0 20.0 40.0 15.0 10.0 5.0 0.0 0 1000 2000 3000 4000 5000 6000 Pressure (psia) Final Liq. Vol. Final Prod. Gas Init. Liq. Vol. Init. Prod. Gas Exp. Liq. Vol. Exp. Prod. Gas 0.0 7000 20.0 Produced Gas, % original mol
Appendix A 161
80.0
60.0
Predict VLE Behavior with Tuned Model Now that the EOS is tuned, it can be used to predict the phase behavior of the gas condensate. Begin by updating the component properties in the data set to reflect the results of the regression as was done after the splitting calculation. Select File|Update component properties, delete all of the rows underneath the Composition row, then save the file under a new name. Specify a Two-Phase Envelope Calculation Click on the row underneath the Composition row. Select Calculations|Two-phase Envelope from the main menu, or click on the toolbar button labeled 2P ENVP, then open the data entry form for the envelope calculation. On the first tab, change the pressure specification to UNKNOWN, the temperature specification to 60, and change the minimum temperature for the X-Axis to 32; leave all of the other envelope specification controls on this tab at the default values. The first tab should now appear like the one below.
On tab Envelope Construction Controls, the phase boundary and quality line calculation can be specified. A value of 0.0 is already entered in the grid for Vol. frac. vapor phase. Below this row, enter values of 0.1, 0.2 and 0.3 to generate quality lines. Also set the Initial step size to 0.1. Save and run the data set to perform the envelope calculation. In the output file, a table showing the Pressure, Temperature, Z-factors and K-values at all points for the two-phase boundary and all of the specified quality lines is given. Select File|Create Excel plots to generate the diagram as shown in the figure below.
Tuned condensate model P-T Diagram
7000 6000 Pressure (psia) 5000 4000 3000 2000 1000 0 0 100 200 300 400 500 600 700 800 Temperature (deg F) 2-Phase boundary 80.000 volume % 90.000 volume % 70.000 volume %
162 Appendix A
Appendix A 163
Specify the Brine Salinity Click on the Aqueous phase tab of the Component Selection/Properties form. On this tab, the aqueous phase salinity can be specified in a variety of units. The salinity is defined in terms of NaCl concentration. Brines are modelled by assuming that the total salinity is due only to Na+ and Cl- ions. In this case it is assumed that total salinity of the brine is 100,000 ppm, thus a value of 0.1 can be entered for the NaCl concentration with the units selected as Weight Fraction. By default, Henrys constants determined using the internal model are for pure water. The value entered for the brine salinity is used to adjust the Henrys constants to account for the reduced solubility of gases in solutions with electrolytes present. Click OK to return to the main form. Check the Stream Compositions Open the Composition form to observe the definition of the primary and secondary compositions, as shown below. The secondary composition is usually defined as the injection fluid, in this case pure CO2. The primary composition is usually defined as the reservoir fluid, thus the hydrocarbon component mole fractions corresponding to the initial reservoir fluid composition are entered here. In this case, the composition of water in the system must also be defined. The mole fraction of water is entered as 1.0 in the primary composition column. After normalization, the resulting mole fraction of water in the primary stream will be 0.5. Close the Composition form by clicking OK or Cancel.
164 Appendix A
Add Flash Calculations to the Data Set Click on the row directly underneath the Composition. To add an Oil-Gas-Water flash to the data set at this point, select Calculations|OGW/EOS Multiphase Flash from the main menu. Your data set should now look like the one pictured below.
Specify Conditions for P-T Flash Double-click on the OGW/EOS Multiphase Flash row to open the data entry form. First, specify the primary mole fraction as 0.5. This means that the feed to the flash calculation will consist of 50 mole % of the combined reservoir oil/water stream and 50 mole % CO2. Select OGW (Oil-Gas-Water) from the Flash Type combo box. Next, enter the specified reservoir temperature of 160 F in the temperature text box. The initial reservoir pressure is 4000 psia. To predict the solubility of CO2 in brine over the full range of expected pressures, a series of flashes from 500 to 4500 psia will be performed. This is accomplished by entering 500 psia in the pressure text box, a pressure step of 1000 psi, and 5 for the number of steps. The data entry form should now appear as below. Click OK to return to the main form.
User's Guide WinProp Appendix A 165
Run the Data Set Specification of the data set to predict the solubility of CO2 in brine at 5 pressures is now complete. Save the data set by selecting File|Save from the main menu. Perform the calculations by selecting File|Run. The results of the calculations can now be viewed by selecting File|ViewOutput from the main menu. Scroll down through the output file until you reach the table with the results for the first flash calculation at 500 psia. The results table should appear as shown on the following page. The table consists of three sections: phase compositions, K-values and phase properties. Note that in the third section of the results table, Phase01 is identified as the aqueous phase. The mole% of CO2 in this phase is reported in the first section of the table as being 0.47996 %. Verify in your results that the only components present in the aqueous phase are CO2 and water. Write down the mole% CO2 in the aqueous phase calculated for each of the 5 flash calculations reported in the output file. These are required for the next stage of the modelling process.
Equilibrium Properties at 500.000 psia and 160.000 deg F Peng-Robinson Equations of State mole percent Component CO2 C1 C3 C6 C10 C15 C20 H2O Feed 50.00000 12.50000 0.75000 1.75000 5.00000 3.75000 1.25000 25.00000 Phase01 0.47996 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 99.52004 Phase02 21.16229 3.03426 1.17901 9.11641 32.39168 24.57394 8.19468 0.34774 Phase03 77.25212 19.93130 0.94408 0.59513 0.09787 0.00264 0.00003 1.17684
166 Appendix A
component
ln (fug,atm)
K-values w.r.t. phase 1 Phase01 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 aqueous Phase02 4.40916E+01 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 3.49413E-03 liquid 0.2764 0.22948 138.06 14846.18 -3351.00 65.566 79.645 37.5588 0.3080 1.3805 7.1776 15.2536 Phase03 1.60955E+02 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.00000E+00 1.18252E-02 vapor 0.8937 0.74208 38.48 -20994.73 -21449.12 38.702 40.187 3.2373 0.0175 49.6694 91.8990 60.3933
Z-factor Molar vol, m3/kmol MW, g/mol Ideal H, BTU/lbmol Enthalpy, BTU/lbmol Ideal Cp, BTU/lbmol-R Cp, BTU/lbmol-R Density, lb/ft3 Viscosity, cp IFT, dyne/cm Phase volume % Phase mole %
0.0223 0.01849 18.14 4924.45 4924.45 8.097 8.097 61.2428 0.9405 0.0000 0.9234 24.3531
Set Up the Regression Run The next phase of the modelling process is to perform a regression run using the predicted solubilities of CO2 in brine as pseudo-experimental data. The results of the regression will be a reference Henrys constant and molar volume at infinite dilution for CO2 which may be included in a GEM data set. Modify the Initial Component Properties Save the data set used for performing the flash calculations in the previous step under a new name using File|Save As . This will be used as the basis for the regression data set. To perform regression on aqueous phase solubility parameters, valid initial values of the parameters must be present in the component table. Open the Component Selection/Properties form and scroll over in the table until the column with Henrys constants is visible. Select AqueousSolubility|Calculate component solubility parameters from the menu. This will bring up a form to enter the temperature and pressure at which you want the initial solubility parameters evaluated as shown below.
Appendix A 167
The pressure entered will be used as the reference pressure for calculating Henrys constants during regression. In this case 500 psia is used. The temperature entered should be the same as the temperature specified for your flash calculations (160 F). Click OK to return to the component table when you have entered these values. Note that molar volumes at infinite dilution and reference pressures have been filled in for all components. Valid Henrys constants have also been entered in the table for CO2, C1 and C3, as these components are considered to be soluble in the aqueous phase by default. Since we are concerned only with the solubility of CO2, the Henrys constants for C1 and C3 should be set to 1.0E+20. The aqueous solubility parameters should now appear as shown below.
168 Appendix A
Before leaving the Component Specification/Properties form, the text box on the Aqueous phase tab for setting the aqueous phase salinity should be cleared or set to zero. This value is used only for predicting the effect of salinity on Henrys constants and should not be used during regression on aqueous phase solubility parameters. Click OK to return to the main form. Specify the Regression Parameters Click once on the row following the composition form to make that the active row. Select Regression|Start from the main menu as shown below to insert a Regression Parameters form at this point.
Double-click on the Regression Parameters row to bring up the data entry form. The only parameters that we want to modify are the reference Henrys constant and molar volume at infinite dilution for CO2. Scroll over on the grid shown on the Component Properties tab to display the last two columns in the grid. Click in the row corresponding to CO2 under the columns labelled Henry Const. and V inf. to select the parameters to use in regression. The form should now appear as shown below.
Click OK to return to the main form. When the dialog box appears asking if you would like to change the number of simultaneous regression parameters, answer No to retain the default value. When there are five or fewer regression parameters specified, the default is to set the
Appendix A 169
number of simultaneous regression parameters equal to the total number of regression parameters specified. Specify the Experimental Data The experimental data must be entered in the data set by specifying a flash calculation for each pressure that we have solubility data for. Begin by double-clicking on the OGW/EOS Multiphase Flash row to edit the existing flash specification. Change the Pressure step to 0.0 and the Number of pressure steps to 1. Also edit the comment to reflect the new specification if necessary. The form should now look like the one pictured below.
Click on the Exp. Solubility tab to enter the data generated earlier for solubility of CO2 in brine. Make sure that the unit selected for entering the solubility is Mole Fraction, then enter the value predicted for the amount of CO2 in brine from the first part of this case study. For the flash at 500 psia, the amount of CO2 in the aqueous phase was calculated to be 0.47996 mole%, thus the entry in the table should be 0.0047996 as shown below. All of the other entries in the table can be left blank. They will default to a value of -1. A negative value indicates that a given experimental data point will not be used in the regression.
170 Appendix A
Click OK to return to the main form. The flash specification with experimental data constructed above can now be copied and modified for the other pressures. Make sure that the OGW/EOS Multiphase Flash row is selected, then select Edit|Copy from the main menu (or press Control-C). Click on the first blank row underneath the OGW/EOS Multiphase Flash, then select Edit|Paste from the main menu (or press Control-V). Double-click on the new OGW/EOS Multiphase Flash row to open the data entry form. Change the pressure to 1500 psia, then click on the Exp. Solubility tab and enter the value of CO2 solubility recorded for this pressure from the first part of this case study. This should be a mole fraction of 0.0101982. Create flash specifications and enter the CO2 solubility data for 2500 psia (0.0121624 mole fraction CO2), 3500 psia (0.0131680 mole fraction CO2) and 4500 psia (0.0139434 mole fraction CO2). Complete and Run the Regression Data Set After the last flash specification, make sure the first blank row at the end of the data set is selected and then select Regression|End to enter an End Regression form into the data set. The completed regression data set should now appear as follows:
Save and run the data set. View the output by selecting File|View output or by pressing the F3 function key. At the end of the output file, two summary tables are printed: Summary of Regression Variables and Summary of Regression Results. Looking at the before and after regression values in the regression results table in comparison to the experimental values shows that the fit has been considerably improved. Investigation of the regression variables table, however, shows that both of the regression variables have reached the default upper bound imposed. This indicates that further improvement to the fit could be obtained by increasing this limit for one or both of the parameters chosen.
User's Guide WinProp Appendix A 171
A summary of the regression iterations appears roughly in the middle of the output file. Examination of this table shows that the Henrys constant for CO2 (indicated by the name HEN1 in the table) reached its limit first during the regression iterations. Thus, we will try increasing the upper bound for this parameter. Modify the Regression Data Set Close the output file, then double-click on the Regression Parameters row to bring up the data entry form. Click on the Variable bounds tab, and change the upper bound for the CO2 Henrys constant to 5500 atm. At this point the convergence tolerance can also be tightened on the tab Regression controls. Enter a value of 0.000001 in the convergence tolerance text box. Click OK to return to the main form, then save and run the data set. Viewing the summary tables at the end of the output file now shows that an excellent match of the CO2 solubility data has been obtained. Close the output file in preparation for the final phase of the modelling process. Create a New Data Set Once the process of tuning the model has been completed, a new data set can be created with all of the updated model parameters. Select File|Update component properties from the main menu. This will overwrite the first three forms in the data set with the model parameters obtained from the regression run. Use File|Save As to save the file under a new name. This new file will be used to generate the fluid model specification for GEM. First, remove all of the calculation options below the composition form. Click on the Regression Parameters row and drag the mouse down to the End Regression row to select all of the calculations, then select Edit|Delete or press the Delete key to remove the calculations as shown below.
172 Appendix A
Add GEM Fluid Model Creation to the Data Set Click on the first blank row underneath the Composition row, then select SimulatorPVT|CMG GEM EOS Model from the main menu as shown below.
This will insert a CMG GEM EOS Model form into the data set. Double-click on this row to bring up the data entry form. Under File Selection, click the check box labelled Print component properties for GEM. It is also possible to get an echo of the component properties to the output file by clicking the check box labelled Print detailed component properties to *.OUT. GEM does not need to have the water component included in the component list, therefore the checkbox labeled Include H2O in GEM component list can be left in its default unchecked state. To output Henrys constants and molar volumes, the check box labelled Print aqueous phase component solubility parameters must also be checked. Note that when the solubility parameters are defined on the Component Selection/Properties form, they are constant for a data set, and the option buttons available under Solubility Parameters will have no effect. Selecting these options only affects the results when the internal model is used to generate Henrys constants and other solubility parameters. The reservoir temperature must also be entered to complete the fluid model description for GEM. The completed form should now appear like the one below. Click OK to return to the main form.
Appendix A 173
Run the Data Set for the GEM Fluid Model Save and run the data set, then view the output file. The table in the output file shows a listing of the properties for all of the components, including the aqueous phase solubility parameters. The GEM fluid model is saved in a file with the same root name as your data file and output file, but with the (.gem) extension (e.g. for the Case2b.dat data file, the GEM fluid model is stored in the file Case2b.gem). The file can be viewed by selecting File|View GEM EOS Model from the main menu. This file contains the same information as shown in tabular form in the output file, but written out in the keyword format required for GEM. The GEM fluid model file can be referenced in a GEM data set using an include statement, or it can be imported into a data set using CMGs ModelBuilder program.
174 Appendix A
Fluid analysis and asphaltene precipitation data are taken from Burke, Hobbs and Kashou, Measurement and Modeling of Asphaltene Precipitation, Journal of Petroleum Technology, November 1990, pp. 1440-1446. The following data for Oil 1 taken from Table 1 of Burke et al will be used in this example. Component Nitrogen Carbon Dioxide Methane Ethane Propane i-Butane n-Butane i-Pentane n-Pentane Hexanes Heptanes plus Total C7+ molecular weight C7+ specific gravity Live oil molecular weight Stock tank oil API gravity Asphaltene content in stock tank oil, wt% Reservoir temperature, F Saturation pressure, psia Fluid Characterization To begin this case study, a data set has been prepared to characterize the fluid by defining the compositions of components up to C6 and pseudo-components describing the C7+ fraction. The data set is named Case_study-3-split.dat and is located in the WinProp templates directory, for example cmg\WinProp\2000.10\Tpl. You can begin by using this file, or by constructing your own data set as described in Case Study Number 1. From the table above, the composition data to C6 has been used, and a Plus Fraction Splitting calculation has been specified with the C7+ molecular weight and specific gravity. The plus fraction will be lumped into 4 pseudocomponents, and the Lee-Kesler critical property correlations will be used. Perform the splitting calculation either by running your own data set, or by running the Case_study-3-split.dat data set. Update the System Component Specification After splitting, the equation of state model can now be tuned to any available PVT data via regression. First, the component specification must be updated to reflect the results of the splitting calculation. This is done by selecting File|Update component properties from the file menu, which will modify the first three forms in the data set. Save the data set under a new name to avoid overwriting the original file by selecting File|Save As ... and entering a new name. Remove the splitting calculation from the data set by selecting the row labelled Plus Fraction Splitting and pressing the Delete key or by selecting Edit|Delete from the
User's Guide WinProp Appendix A 175
Oil 1 0.57 2.46 36.37 3.47 4.05 0.59 1.34 0.74 0.83 1.62 47.96 100.00 329 0.9594 171.4 19.0 16.8 212 2950
main menu. Open the Titles/EOS/Units form and enter a new comment and descriptive title. Open the Component Selection/Properties form and click the check box to Use temperature-dependent volume shifts. This will allow good initial predictions of the volumetric properties of the fluid. After closing this form, the calculation options required to perform the regression can be added to the data set. Set up the Regression Data Set Select the first blank row underneath the Composition row. Enter a Regression Parameters form into the data set by selecting Regression|Start from the main menu or by clicking the Strt Reg button the toolbar. Then enter a Saturation Pressure calculation by clicking the Sat Pres button, and an End Regression form by clicking End Reg. Open the data entry form for the Saturation Pressure calculation and enter a temperature of 212 F, saturation pressure estimate of 2500 psia, and an experimental saturation pressure measurement of 2950 psia. Close this form and open the Regression Parameters form. Go to the Interaction coefficients tab and click the option button for Select from list, then select HCIntCoefExp 1 from the list. This selects the hydrocarbon interaction coefficient exponent as a regression variable. For more information about this parameter, please refer to the Components section of the Users Guide. Go to the Regression Controls tab and set the Convergence tolerance to 0.00001 to achieve a good match to the experimental data. Click OK to close the Regression Parameters form. Before the form closes, a dialog box appears asking if you would like to change the number of simultaneous regression parameters. Click No to accept the default value. The data set should now look like the following:
A copy of this data set, Case_study-3-regress.dat is available in the templates directory for comparison to your own work. Run the data set, then view the output from the run. The regression summary table at the end of the output file shows that an exact match to the saturation pressure was achieved. The model is now ready to be modified for asphaltene precipitation prediction. First update the component properties as before, then save the file under a new name.
176 Appendix A
Specification of Asphaltene Component Again, a new title and descriptive comment can be added to the Titles/EOS/Units form if desired. The asphaltene component is specified by splitting the heaviest component of the oil into precipitating and non-precipitating components. These two components have the same critical properties and acentric factors, however the precipitating component has higher binary interaction coefficients with the light components up to about C5. This is achieved in WinProp by adding a new component to the component list, then copying the properties of the heaviest component, onto the newly added component. Open the Component Selection/Properties form. Begin by unchecking the check box for Use temperature-dependent volume shifts, this allows the volume shifts to be fine tuned to density data. In the component table, click on the row directly underneath the component C31+. Enter any hydrocarbon component from the library by selecting Options|Insert library component, clicking on FC6, then clicking OK. Select the entire row of C31+ properties by clicking on the row label 14 at the left side of the table. Copy the properties to the clipboard by using Ctrl-C or selecting Edit|Copy from the menu, as shown below.
Now click on the first column in the row for the component that you just entered, i.e. click on the component name FC6, and use Ctrl-V or Edit|Paste to paste the properties onto the new component. The component names can now be edited, for example C31A+ and C31B+. To be able to specify interaction coefficients with the other components individually for the C31B+ component, as opposed to calculating them with the hydrocarbon interaction coefficient exponent, the HC flag in the column next to the component name can be set to 0. The component list should now appear as follows:
Appendix A 177
Click on the Int. Coef. tab, and click on Show HC Int. Coef. to view the magnitude of the binaries between C31A+ and the light components. As described in references 19 and 20, the binaries for the precipitating component must be considerably higher than those for the nonprecipitating component to give the correct shape of the precipitation curve below the bubble point. Values on the order of 0.2 are expected to give good results. For C31B+, enter the same binaries as C31A+ for CO2 and N2, then enter values of 0.2 for the interactions with C1 through nC5. All other values for C31B+ should be left as zero. Click OK to complete the component specification. Specification of Asphaltene Composition The mole fraction of the asphaltene component can be determined from the relation: xAsph MWAsph = wAsph MWOil. From the output of the regression run, the molecular weight of the oil is calculated as 171.343, as compared to the reported value of 171.4. The asphaltene content of the stock tank oil is given as 16.8 wt%. As the weight fraction of gas in the live oil is usually small, the value of 16.8 wt% will be used for the live oil. From the component table, the molecular weight of the C31B+ component is 665.624. This results in a mole fraction of 0.04324607 for the precipitating component. Open the Composition form and enter this value for the mole fraction of C31B+. Subtract this amount from the original mole fraction of C31+, and enter 0.07424660 as the mole fraction for C31A+. Click OK to close the form. Specification of Additional Regression Data When the heaviest component is split into precipitating and non-precipitating parts, and the binaries for the asphaltene component are adjusted, the fluid phase behavior predictions will be affected. For this reason, regression must be performed again to ensure that the model will predict the correct fluid and solid phase behavior. In this data set, we will add regression on the stock tank oil API as well as the saturation pressure. Click on the End Regression row, then click the SEP button to insert a separator calculation into the data set. Open the Separator form and enter an estimate for the saturation pressure of 2500 psia and a temperature of 212 F in the
178 Appendix A User's Guide WinProp
first column of the separator specification. Go to the Experimental Data tab and enter 19.0 for the stock tank oil API and click OK. To match the experimental API, we will modify the volume shift parameters of the heavy fraction pseudo-components. As the volume shift of the asphaltene component affects the amount of precipitate, as well as the liquid density, it will not be adjusted during regression. Open the Regression Parameters form and click in the Vol Shift column in the rows corresponding to the components C07-C15, C16-C25 and C26-C30 to select these parameters as regression variables. Click OK and again select NO on the dialog box to leave the default number of simultaneous regression variables. Specification of Reference Fugacity for Asphaltene Model The equation describing the fugacity of the solid component in the solid phase is given in the Flash Calculations chapter of the Users Guide. Writing this equation for isothermal conditions gives
ln f s = ln f s* + v s (p1 p o ) / RTo
*
(1.1.1)
where fs is referred to as the reference fugacity, at the reference conditions po and To. vs is the molar volume of the solid. The reference fugacity is usually set equal to the fugacity of the precipitating component calculated by the equation of state at an experimentally determined asphaltene precipitation onset pressure for a given temperature. This ensures that the model will predict the correct onset pressure. At other pressure conditions, the fugacity of the solid component in the solid phase is compared to the fugacity of the solid component in the liquid phase as predicted by the equations of state, if the fugacity of the solid component in the solid phase is lower then asphaltene will precipitate. With modern solid precipitation detection systems, onset pressures can usually be determined quite accurately. In the Burke et al data, an exact onset pressure is not given, instead, a pressure point above the saturation pressure at which a small amount of asphaltene precipitates is determined. The data given (in Burke et al Table 5) is 0.402 wt% asphaltene precipitated at 4014.7 psia and 212 F. To use this data, the reference fugacity is determined at the given pressure and temperature, but with the precipitated amount of asphaltene removed from the system. The reported wt% of precipitated asphaltene must again be converted to a mole fraction to enter into WinProp. Using the same formula and molecular weights as before, the mole fraction of precipitated asphaltene is determined as 0.001034817. Click on the Composition form, then use Ctrl-C to copy the form. Click on the row underneath the End Regression form and use Ctrl-V to paste a copy of the composition form. Open the new Composition form, and subtract the amount of precipitated asphaltene from the mole fraction of component C31B+, the resulting mole fraction should be 0.042211253. When you click OK, a warning that the composition no longer sums to 1.0 will be issued, this can be ignored as all compositions will be normalized. Click on the row below the new composition form and then click the ASP/WAX button on the toolbar to enter a new Asphaltene/Wax Modelling form in the data set. Open the form and enter the reference conditions of 4014.7 psia and 212 F on the first tab. Click on the Ref. State tab and select CALCULATE for the Reference Fugacity Specification. This will set the reference fugacity equal to the fugacity of the precipitating component in the liquid phase calculated by the equation of state. Click OK. The data set should now appear as follows:
Appendix A 179
As discussed in reference 19, the solid molar volume should be set to a value slightly higher than the molar volume for the precipitating component predicted by the equation of state. At this point we can run the data set to check the regression on the fluid PVT data and to view the solid molar volume predicted by the EOS. Run the data set and view the output file. The regression summary table shows that both the saturation pressure and stock tank API are matched exactly. At the end of the file, a listing of the parameters of the solid model are given. The solid molar volume is given as 0.65883 L/mol. A good initial value to enter for the solid molar volume is 0.67 L/mol. Return to the data set and open the Asphaltene/Wax Modelling form and go to the Ref. State tab. Scroll over in the grid showing the properties of the C31B+ component and enter 0.67 under Molar Vol. This molar volume will be used by all subsequent asphaltene precipitation calculations. Click OK close the form.
Prediction of Asphaltene Precipitation
To perform predictions of asphaltene precipitation, we need to use the whole live fluid composition, not the composition adjusted for the reference fugacity calculation. Click on the first Composition row in the data set (row 3) and use Ctrl-C to copy it to the clipboard. Now click on the row underneath the Asphaltene/Wax Modelling form and use Ctrl-V to paste the Composition form. Then add a new Asphaltene/Wax Modelling form at the end of the data set. Open the form and enter a temperature of 212 F. We want to predict the amount of asphaltene precipitated at various pressures. Enter a Pressure of 14.7 psia, a Pressure Step of 200 psia and a No. of pressure steps of 31. This specification results in flashes being performed every 200 psi from 14.7 to 6014.7 psia.
180 Appendix A
Click on the Ref. State tab and set the Reference Fugacity Specification to PREVIOUS. This specifies that the reference fugacity for the asphaltene model will be set to that value determined in the previous asphaltene flash, where the reference fugacity was set to CALCULATE. The molar volume, reference pressure and reference temperature set previously will also be used. Now go to the Plot Control tab, click on the X-Y Plots option button, then check the Plot weight % solid phase checkbox. Click OK to close the form. The final data set is now ready to run, and should appear like the one below.
Run the data set, and click on the button with the Excel icon on the toolbar to create the plots. You should see that the shape of the asphaltene precipitation curve from the upper onset pressure to the saturation pressure shows the expected trend of increasing precipitation with decreasing pressure. Note also that the predicted amount of asphaltene at the reference pressure of 4014.7 psia is exactly equal to the experimental value of 0.402 wt%. The shape of the curve at lower pressures is incorrect. The final step in this case study discusses how to adjust the solid model parameters to achieve the correct shape of the precipitation curve.
Adjustment of Solid Model Parameters
As the solid precipitation model used in WinProp is thermodynamic, as opposed to kinetic, reversibility of precipitation is possible. i.e. precipitated solids can redissolve in the liquid phase. This phenomena has been observed in the laboratory for pressure depletion. Usually the maximum amount of precipitation occurs around the saturation pressure of the fluid. Below this pressure, liberation of gas from the oil changes the solubility parameter of the liquid phase and allows redissolution of the precipitated asphaltene. It is possible that all of the precipitated asphaltene will go back into solution at sufficiently low pressures. The parameters that control this behavior in the solid model are the solid molar volume and the interaction parameter between the precipitating component and the light ends of the oil. Increasing the solid molar volume increases the maximum amount of precipitation at the saturation pressure. Increasing the interaction parameter with the light ends will force the
User's Guide WinProp Appendix A 181
asphaltene to redissolve at lower pressures. The experimental data given in Burke et al (Table 5) indicates the maximum amount of precipitation from this fluid should be about 1%, and that the amount of precipitation should decrease to 0.403 wt% at 1014.7 psia. Judging from the results of the initial run, it is seen that the molar volume of the solid must be increased slightly to increase the maximum amount of precipitation from approximately 0.8 wt% to 1 wt%. The interaction parameter between the precipitating component and the light ends must also be increased to give the correct shape of the precipitation curve below the saturation pressure. As noted earlier, performing the regression within the asphaltene modelling data set allows the model to predict the correct fluid PVT behavior when the interaction parameters for the asphaltene component are changed. Adjust the solid molar volume first to achieve the desired maximum amount of precipitation. In this case, a value of 0.675 L/mol was found to give good results. After this step, adjust the interaction parameters between the C31B+ component and the components C1 through nC5. Using a constant value of 0.224 for all of these interactions gives a good shape to the precipitation curve, although it doesnt match exactly the experimental data. For comparison with your work, the final model is given in the template data set Case_study-3-asph.dat. The asphaltene precipitation plot from this data set is shown below.
Burke Oil 1 asphaltene modelling Phase Properties (Solvent Mole Fraction = 0.0000)
1.20 Solid Precipitate (wt %) 1.00 0.80 0.60 0.40 0.20 0.00 0 1000 2000 3000 4000 5000 6000 7000 Pressure (psia) 212.00 deg F
182 Appendix A
Appendix B
Equations
The following are the equations used in WinProp.
p= or
RT a 2 v b v + vb(1 + c ) cb 2
(2.1.1a)
p= where
RT a v b (v + 1 b )(v + 2 b )
(2.1.1b)
21 = (1 + c )
(1 + c)2 + 4c
1 2 = c
When c=1, Equation (2.1.1a) becomes the Peng-Robinson Equation of State and when c=0, it becomes the Soave-Redlich-Kwong Equation of State. For pure components, the parameters a and b are expressed in terms of the critical properties and the acentric factor:
a = a c
a c = a (RTc ) / p c
= 1 + 1 T / Tc b = b RTc / p c
Define
A ap /( RT ) 2 and B bp / RT
(2.1.2)
Appendix B 183
E Z 3 Z 2 (1 cB) + Z A B(1 + c ) B 2 (1 + 2c ) AB c B 3 + B 2
a = x i Si
i
] [
) ]= 0
(2.1.3)
For mixtures, the parameters a and b are defined using the following mixing rule
Si a i x j (1 d ij ) a j
j
b = x i bi
i
(2.1.4)
where dij is an empirically determined interaction coefficient. The fugacity coefficient is derived from the equation of state (Michelsen, 1981) ~ F ln = n ln Z T,v
where
N ~ p dV F RT V v
(2.1.5)
Resulting in
ln i =
bi 2S i b i Z + 2 B (Z 1) ln(Z B) 1 A ln b 2 1 B a b Z + 1 B
(2.1.6)
Calculation of Parameters
The above equations require the knowledge of a, b and . The two parameters a, b are obtained from the critical condition. At the critical point, the compressibility factor will have three real and equal roots (Martin, 1979).
(Z Z c )3 = 0
Comparing with the above Z equation results in
b = 1 / (3Z1 + c )
3 b = ( Z1 + c + c / b ) 2 b
Z c = b Z1
where
Z1 1 + Z 2 + 2 / Z 2 Z 2 (3 + c + Z 3 ) Z 3 c 2 + 6c + 1
184 Appendix B User's Guide WinProp
1/ 3
Equation (2.1.7)
The is obtained from the following empirical correlations. For the PR equation of state, Peng and Robinson (1976) proposes = 0.37464 + 1.54226 0.26992 2 and for hydrocarbons heavier than n-decane (Robinson and Peng, 1978) = 0.379642 + 1.48503 0.164423 2 + 0.016666 3 For the SRK equation of state, Soave (1972) proposes = 0.480 + 1.574 0.176 2 While the following equation is suggested by Grabowski and Daubert (1978) = 0.48508 + 1.55171 0.15613 2
Selection of Compressibility Root and Vapor/Liquid Identification
The cubic Z-factor equation may yield two real roots. In which case, the one that results in the lowest Gibb's free energy (i.e. most stable) will be selected. Let ZA and ZB be the two real roots resulting in free energy GA and GB respectively. Since free energy G = x i ln f i ,
i
ZB B 1 A Z B + 2 B Z A + 1 B G A G B = ln Z + B Z + B (Z B Z A ) Z B + B ln 2 1 2 B 1 A A
(2.1.8)
If GA - GB > 0, ZB will be selected and vice versa. For single-phase fluids, if the above scheme selects the largest Z root, the fluid is said to be vapor. Similarly, if the smallest positive Z root is chosen, the fluid is said to be liquid. In cases where the Z-factor equation yield only one real root, the naming of the phase to be vapor or liquid is irrelevant. For identification purposes, the criteria according to Gosset et al (1986) is used. The fluid is designated as liquid when A/B > a / b and Z < (Zc/b)B, else it is designated as vapor. For simplicity, the EOS Zc as shown in Equation (2.1.7) is used in the above criteria. For multiphase fluids, the phases are identified according to their mass densities. The lower density phase is arbitrarily denoted as vapor.
Appendix B 185
The volume translation technique of Peneloux et al (1982) is used to improve the density prediction capability of the SRK and PR equation of states. Consider pressure-explicit equation of state of the form:
(v i / RT 1 / p )dp + ln(x i p )
(2.1.10)
(2.1.9)
where vi is the partial molar volume. The equilibrium conditions require that ln f iL = ln f iv
A volume translation modifies the molar volume of the system v predicted by the equation of state as follows: (2.1.11) vt = vo ~ v ~ v = x i ri
ri = t i B ci and
B ci = b
RTc pc
where ti is the dimensionless individual translation value for each component and the superscripts o and t correspond respectively to the results before and after the volume translation. Bci is the hard core molecular volume of component i. By using equation (2.1.11), the fugacities of the component i after the volume translation become: ln f it = ln f io pri / RT Thus if
ln f iL = ln f iv , then ln f iL
(2.1.12)
( )
( )
( )
= ln f iv
( )
i.e. the volume translation has no effect on the equilibrium conditions. Therefore, it will not alter the saturation pressures, saturation temperatures, equilibrium compositions, etc. However, it will modify the molar volumes, compressibility factors and densities of the fluid. The following equations show the effect of equation (2.1.11) on the parameters of interest to petroleum engineers. Compressibility Z t = Zo v t / vo Gas oil ratio, GOR
(2.1.13)
GOR t = GOR o v o / v t
stc
(2.1.14)
186 Appendix B
Mass density,
t = o vo / v t
(2.1.15)
where the subscript stc denotes the stock tank (standard) conditions. Other equations of interest can be derived easily using equation (2.1.11). The use of the volume translation technique requires the knowledge of ri for each component. These can be estimated from equation (2.1.13) at the critical conditions
(Z c )i = (Z c )EOS (v c
ri ) / v ci
where (Zc)EOS is the compressibility factor from the equation of state as shown in Equation (2.1.7). Peneloux et al (1982) have tabulated values of ti for the first ten components in the alkane series. Jhaveri et al (1984) have also developed empirical equations for ti. Generally, for phase behavior matching, it is advantageous to treat ti as regression variables. Experience shows that it is sufficient to introduce non-zero ti's for the C6+ components and methane only. Furthermore, for the C6+ components, it is preferable to have one ti value for all components, e.g.
The excess enthalpy, HE, of a fluid which follows the EOS in Equation (2.1.1) is given by: H E H H* = pv RT + and the excess capacity
Cp E H E / T
T(a / T ) a v + 2 b ln ( 2 1 ) v + 1 b (2.1.17)
(2.1.16)
where H is the system enthalpy and H* is the enthalpy at the ideal gas state, calculated from
H* = x i H* i
i
Hi is a function of temperature only and can not be derived from the EOS and has to be input by the user in the form of a polynomial
2 3 4 5 H* i = H A + H BT + H CT + H DT + H E T + H FT
With T in deg. R and Hi* in Btu/lb. HA through HF are user specified parameters. Passut and Danner (1972) have compiled the values of HA through HF for components commonly encountered in Petroleum Engineering. In most practical uses, the important variables are the enthalpy differences and not the absolute enthalpies. Thus, the reference point for H can be chosen arbitrarily. In WinProp enthalpy is assigned zero when the component is at ideal gas state at zero kelvin.
Appendix B 187
( )
where
K ip = u i / x i
and ~ ui = ui / u k
k
ui <1
and vice versa. If the phase is unstable, the equilibrium ratio Kip is a good first guess to initiate equilibrium calculation. Equation (2.2.1) is solved using the QNSS method described in Viscosity Correlation section. To solve the above stability test equation, the following initial guess can be used:
Initial Guess
i
Description
Pure component u i = 1, u j, ji = 0 i = 1,..., N c
Nc+1
Ideal gas ln u i = ln i (X ) + ln (x i )
Nc+2
Average
u i = (y il + y iv ) / 2
Nc+3 Wilson's equation ui = xi Nc+4 p ci p e
+ 5.373(1+ i )(1 Tc i / T )
Initial guess (Nc+2) is generally used to test the stability of a liquid-vapor two-phase system only.
188 Appendix B
The initial estimates of the stability test is set according to the input variable LEVEL.
Level
0 1 2 3 4
where H1, H2 correspond to the heaviest and next heaviest component in the system and L1, L2 correspond to the lightest and next lightest component.
START
ui <1
No
Phase unstable
Yes
Yes
Phase stable
Appendix B 189
( )
( )
i=1,...,Nc
z k (K k 1) =0 1 + Fv (K k 1)
(2.3.1)
where K i = x iV / x iL z = global composition of the feed Fv = vapor phase mole fraction and x iL = z i /[1 + Fv (K i 1)] When 0 < Fv < 1, the feed splits into two equilibrium systems. When F < 0, the feed is stable at the specified pressure and temperature but addition of a phase with composition XV to the feed Z will result in a phase with composition XL in equilibrium with XV. The equilibrium equation is solved using the QNSS method described in Solution of NonLinear Equations section, the primary variables are ln Ki with initial guesses from the Wilson's equation:
Tci ln K i = 5.37 (1 + i ) 1 T
+ ln (p ci / p )
(2.3.2)
In solving the material balance equation, the method of Nghiem, Aziz and Li (1983) is used for quick single-phase detection. With fo = zk K k
k
f1 = z k / K k
k
(2.3.3)
the system is a single-phase liquid when fo < 1 and a single-phase vapor when f1 < 1.
190 Appendix B
START
Initialization
Solve material balance equation for vapor phase mole fraction and composition
No
Single Phase
Use QNSS to solve the equilibrium equation once and update K-values
Yes
Stability Test No
Unstable
Convergence
Stable
Yes
Two-Phase System
STOP
Saturation Calculation
Saturation condition of a mixture XL at a particular pressure p and temperature T requires that the tangent plane to the Gibb's free energy surface at XL is also tangent to the surface at some other composition XV. The p and T are the saturation pressure and temperature and XV is the equilibrium composition (Nghiem, Li, and Heidemann, 1985), i.e. G i ln K i + ln iV ln iL = 0
D
i
1=1,2,...,Nc
(2.4.1)
x iV ln K i + ln iV ln iL V x j j
=0
(2.4.2)
Appendix B 191
where G is the equilibrium equation and D is the normalized distance from the Gibb's free surface to the tangent plane at x, evaluated at a composition y where: iV = i X V , p, T iL
L i
( = (X
) , p, T )
K i = x iV / x iL
(2.4.3)
For saturation pressure (temperature) calculation, the primary variables are ln Ki and p(T). The Nc equilibrium equation (2.4.1) can be solved by the QNSS method and during each QNSS iteration, update p(T) from the distance equation (2.4.2). This is similar to the general scheme used to solve the two-phase flash problems.
(2.4.4)
respectively. These distances can be regarded as functions of a single variable (temperature or pressure) as long as the mole fractions y are held constant at values derived from equation (2.4.4). When the saturation temperature is specified, a one-dimensional search is performed to locate all the pressures which satisfy
(0 ) D1 =0
and
(0 ) D* =0 2
(2.4.5)
Similarly, these equations are solved for all the temperature roots at a specified saturation pressure.
192 Appendix B
The technique used to solve equation (2.4.5) for temperature or pressure is a one-dimensional search combined with bisection or Newton's method. The saturation calculation using one of the Newton methods or QNSS is then initialized with the yi values given by equation (2.4.4) and the pressure and temperature conditions that satisfy equation (2.4.5). In some cases, equation (2.4.5) was found to have more than one pressure root (at the given temperature) or more than one temperature root (at the given pressure). The saturation calculation can be initialized with any one of these starting guesses. It has been observed that convergence can be obtained to a different solution for each of the starting guesses. In some problems, several of the converged solutions are physically meaningful, such as lower and upper dew point pressures in retrograde systems or points where liquid-liquid separations occur. Some of the converged points are found to lie inside the two-phase region, however, and are "trivial" solutions in the sense that the calculated V phase is identical to the starting L phase. It has been observed that such trivial solutions, when they are found, lie on the stability limit of the homogeneous fluid.
Cricondenbar/Cricondentherm Equations
The cricondenbar/cricondentherm for phase X is taken as a saturation point with additional constraints. It solves the Nc+1 saturation equations (Nghiem, Li and Heidemann, 1985): G i ln K i + ln i X V , p, T ln i X L , p, T = 0 D y i ln K i + ln i X V , p, T ln i X L , p, T
i
) ]= 0
Analytical derivatives for ln could be used. The primary variables are ln Ki, p and T.
i = 1,..., N c
(2.6.1)
(K i 1)z i = 0 1 + Fv (K i 1)
(2.6.2)
where K i = x iV / x iL
User's Guide WinProp Appendix B 193
For specified z1 and z2, the variables required to completely determine the system are p, T, Fv, K1, K2,..., KNc, . A total of Nc+4 variables with Nc+1 equations (2.6.1 and 2.6.2). All variables are designated into three groups: i ii iii Nc+1 primary variables, 1 specified variable, 2 fixed variables
The values of the fixed variables will be kept constant throughout the calculations. For each point in the phase envelope, the value of the specified variable is fixed and the Nc+1 equations solved to give the Nc+1 primary variables. The value of the specified variable is then incremented and the whole process is repeated to form the complete phase diagram. The secondary variables xiL and xiV are computed from x iL = z i /[1 + Fv (K i 1)] x iV = z i K i / [1 + Fv (K i 1)] Various phase diagrams are formed by different designation of variables: (2.6.3)
The natural log is used to bring the magnitude of all the variables to a comparable basis.
Ki =
p ci p
i=1,...,n
Newton's method is used to solve for 1. After convergence has been achieved, i.e.
2 ( (kk,i+1) (kk,i) ) < n +1 i =1
one proceeds to the next point on the phase envelope. The efficiency of the method depends upon: 1. the initial guess 2(0), and 2. the specified variable 2 Once 2 is specified, Michelsen obtained the initial guess 2(0) by linear extrapolation. Let J1 be the Jacobian (G / )1. The inverse J1-1 is known from the last Newton's iteration of the first point on the phase envelope. Differentiation of the equation G- = 0 (equation 2.6.1) with respect to at 1 and 1 yields: -1 G = J 1 1 1 The above equation is used to obtain the initial guess 2(0) at 2 by linear extrapolation:
(20 ) = 1 + ( 2 1 ) 1
for the k-th point on the phase envelope with k 3, Michelsen used a third order extrapolation of the form:
) 3 (20,k = a k 0 + a k1 k + a k 2 2 k + a k3 k
(2.6.4)
where akj, j=0,1,...,3, are the coefficients of the polynomial computed using the information of the last two points (i.e. k-1, k-2). The step size, or in other words, the difference between two subsequent specifications k-1 is chosen within prescribed limits such that an increase takes place if less than 3 iterations are used to solve the equations, and a decrease takes place if more than 4 iterations are used. Usually, the step size is multiplied by a factor greater than one in the former case, and multiplied by a factor less than one in the latter. Although the phase envelope construction starts with a specification of pressure, another variable can become a specified variable at its place during the construction of the phase envelope. Indeed, if (/)k-1 is large in magnitude making the extrapolation inappropriate, the variable corresponding to k-1 will become a primary variable for the k-th point, and the one corresponding to k-1,i will become the specified variable.
Appendix B 195
The phase envelope construction does not restrict to the bubble point locus (F=0) or dew point locus (F=1) construction. The locus of any given F(0F1) can also be generated. For convenience, the locus corresponding to 1-F is always generated along with the one corresponding to F. Michelsen also uses an interpolation polynomial of the form (2.6.4) based on points on each side of the critical point to estimate the latter. The criteria used are that the Kvalues are equal to one at the critical point. He reported that the pc and Tc obtained are accurate to 1 kPa and 0.01 K respectively. The same approach is used to estimate the cricondentherm where T/p = 0 and the cricondenbar where p/T = 0.
START
Specify ,
Set up initial guess
Calculate one point on the phase diagram Set up Jacobian matrix Solve the equations
Update variables Trivial root No Unphysical results Yes
STOP
Yes
No
One point in the phase diagram converged
Stability check
Output
Printer plot
STOP
196 Appendix B
ln K iq + ln iQ ln iL = 0
where K iv = x iV / x iL and
(2.7.1)
K iq = x iQ / x iL
Material balance equations
i=1,...,Nc
Nc
(x
Nc i =1 Nc
V i
x iL =
i =1
(K iv 1) z i
Fl + Fv K iv + Fq K iq
=0
(x iQ x iL ) =
Nc i =1 i =1
(K iq 1) z i
Fl + Fv K iv + Fq K iq
=0
(2.7.2)
with the constraint Fl + Fv + Fq = 1. Subscript L and Q denote the liquid 1 and 2 respectively. A three phase flash calculation corresponds to solving the 2Nc+3 nonlinear equations for the 2Nc+2 primary unknowns ln(Kiv), ln(Kiq), Fl, Fv and Fq. The mole fractions are treated as dependent variables: x im = K im z i / (K iv Fv + K il Fl + K iq Fiq ) (2.7.3)
A stage wise procedure is used for the three phase flash calculation. A two phase calculation is first performed. The initial guess for the third phase is then obtained from the stability test. QNSS method is used to solve the equilibrium equations. During each iteration, equations (2.7.2) are used to update Fl, Fq and Fv.
Appendix B 197
START
Stability test
Stable
No
STOP
H add
z, T 1, P
y 1 T 2, P y 2 H spec yn
where yij is the mole fraction of Component i in Phase j and R is the reference phase for the Kvalue definition. Note that Ri need not be the same for all components. This gives extra flexibility to define K-values in the cases that components are not always present in all phases. The values of these K-values are obtained from an EOS by solving equilibrium equations. By definition KiR, = 1. Let Fj be the mole fraction of phase j in the system, the compositions can be obtained from material balances as follows y ij = and i = Fk K ik
k =1 np
z i K ij i
(2.8.2)
(2.8.3)
From the constraints that the mole fractions must sum up to unity, (np-1) independent equations can be derived
g j y ij y in p = 0
i =1 nc
j=1,...,np-1
(2.8.5)
z i K ij K in p i
)=0
j=1,...,np-1
(2.8.6)
Appendix B 199
The above are the material balance equations used in isothermal flash calculations. For isenthalpic flash calculations, there is an additional energy balance equation, i.e. g n p H H spec = Fj (y ij h ij ) H spec = 0
nc j=1 i =1 np
(2.8.7)
where Hspec is the specified molar enthalpy of the system and hij is the partial molar enthalpy of Component i in Phase j which is also obtained from an EOS. Equations (2.8.6) and (2.8.7) form a system of np equations for the np unknowns T and Fj (j=1,...,np-1). As the phase mole fractions must sum up to unity, it follows that Fn p = 1
n p 1
j=1
Fj
(2.8.8)
The K-values are obtained from the following thermodynamic equilibrium equation
ln K ij + ln ij ln iR i = 0
i = 1,..., n c j Ri
(2.8.9)
Equation (2.8.9) is derived from the equality of fugacities. ij is the fugacity coefficient of Component i in Phase j estimated from an EOS and is a function of pressure, temperature and phase compositions. In using an EOS, the compressibility root corresponding to the minimum Gibb's free energy is selected unless stated otherwise. Note that Equation (2.8.9) represents a system of nc nonlinear equations and is solved iteratively with the material balance and energy balance equations.
(x iV x iL ) =
Nc Nc i =1 Nc i =1
(K iv 1)z i
Fl + Fv K iv + Fw K iw
=0
(x iW x iL ) =
Nc i =1 i =1
(K iw 1)z i
Fl + Fv K iv + Fw K iw
=0
(2.9.2)
User's Guide WinProp
200 Appendix B
with the constraint Fl + Fv + Fw = 1. A three-phase flash calculation corresponds to solving the 2Nc+3 nonlinear equations for the 2Nc+3 primary unknowns Kiv, Kiw, Fl, Fv and Fw. The mole fractions are treated as dependent variables: x im = K im Z i / (K iv Fv + Fl + K iw Fw ) (2.9.3)
For the components j which are assumed not soluble in the aqueous phase, take Kjw = 0 and remove the corresponding equilibrium equation from the equation set. The system of equations can be solved by the quasi-Newton successive substitution method discussed in Nghiem and Li (1984) and Mehra et al (1984).
Thermodynamic Models
The liquid and vapor phases are modelled by the cubic EOS, and the solubility in the aqueous phase is handled by Henry's law. Henry's law for a component sparingly soluble in the aqueous phase states ln iW = ln (H i / p ) iw (2.9.4)
where the bold superscript w denotes the water component, and the regular subscript w denotes the aqueous phase. Hi is the Henry's law constant of component i in the aqueous phase. The variation of Henry's law constant with respect to pressure and temperature follows the equation:
ln H i = ln H * i + v i p / (RT )
(2.9.5)
where H* is a reference Henry's law constant. The molar volume at infinite dilution vi is computed from the correlation of Lyckman et al (1965) reported by Heidemann and Prausnitz (1977) in the form: p ci v i RT ci T p ci = 0.0095 + 2.35 CT ci (2.9.6)
(2.9.7)
pws is the saturated vapor pressure of water at the temperature T, pws is the molar volume of water at pws and T, and hws - hwo is the enthalpy departure of liquid water pws and T. The fugacity of the component water in the aqueous phase can readily be obtained from the fugacities of the solutes using the Gibb's-Duhem equation as in Prausnitz (1969):
p v w w s w w fw exp dp = xw w pw RT p sw
(2.9.8)
where ws is the fugacity coefficient of pure water at pws and vpws is the molar volume of pure water.
Appendix B 201
can be calculated respectively from the Frost-Kalkwarf-Thodos and the Yen-Alexander equation reported in Reid et al (1977). The molar volume vws is estimated from a correlation due to Chou reported in Rowe and Chou (1970). The fugacity coefficient ws is obtained from the following correlation which was found to match reasonably well the data in Canjar and Manning (1967):
5 s T ' 6.1750 x 10 7 T '2 w = 0.9958 + 9.68330 x 10 3.08333 x 10 10 T '3 ; T ' > 90 =1 ; T ' 90 T = 1.8T 459.67
(2.9.9)
where T is the temperature in K, and T' is the temperature in F. Initial guesses for the K-values are: K iw = K iv p / H i The following table summarizes the reference Henry's law constant stored in WinProp (Li and Nghiem, 1986). K iv = p ci / p exp[5.42(1 + i ) (1 Tci )]
Coefficients Component
Methane Ethane Propane n-Butane n-Pentane n-Octane Carbon Dioxide Carbon Monoxide Nitrogen Hydrogen Sulfide (1) 0.2
A
10.9554 13.9485 14.6331 13.4248 16.0045 31.9431 11.3021 10.7069 10.7090 10.8393
B
11.3569 13.8254 14.4872 13.8865 16.2281 28.6725 10.6030 11.1313 11.4793 9.8897
C
1.17105 1.66544 1.78068 1.71879 2.13123 4.37707 1.20696 1.08920 1.16549 1.11984
Water Interaction Coefficient 0.4907 0.4911 0.5469 0.5080 0.5000 0.4500 (1) 0.2000 0.2750 0.1200
H* 10 3 10 6 i = A + B C ln fs T T2 w
202 Appendix B
T fws Hi*
: : :
L Disappears
Unstable
Stable
Disappears
V or L Disappears
L-V
W-L
L-V-W
STOP
Q N = 0
and
(2.10.1)
C=
i
j k
3A n i n j n k
n i n j n k = 0 T ,V
(2.10.2)
An efficient successive substitution solution procedure of the above equations has been proposed by Michelsen and Heidemann (1981) and summarized as follows: Select an initial value of ( vc/b).
User's Guide WinProp Appendix B 203
Calculate Tc such that det(Q) = 0 by Newton's method. Evaluate N such that QN= 0. To avoid discrete jumps in N, normalize N by NTN= 1. Evaluate the cubic form C* C (-1)2 and update (k +1) = (k ) C *
(k )
(( ) ( ) )/ (C ( ) C ( ) )
k k 1 *k * k -1
The factor (-1)2 is added to enhance stability. Repeat this process until C* = 0. Initial estimates suggested are = 3.5, Tc = 1.3 x i Tci . Another method to initiate the
i
calculation is to start with fixed step size of (say 0.1) until the cubic form (equation 2.10.1) changes sign. Then follow the above solution procedure.
START
Initialize Tc
Set initial vc / b
Yes
Yes
Calculate cubic form Maximum reached Cubic form=0 Yes Calculate P c from Vc , Tc STOP Yes No critical point detected No
Update
No
STOP
Viscosity Correlation
In analogy to the Jossi, Stiel and Thodos equation, the following viscosity correlation is used (Fong and Nghiem, 1980):
204 Appendix B
[( ) + 10 ]
*
4 1 / 4
3 4 = a 0 + a1r + a 2 2 r + a 3r + a 4 r
(2.11.1)
(2.11.2)
where vc is the critical molar volume used in the viscosity correlations. Generally vc is identical to the critical volume of the component. In WinProp, these are user input parameters which may be obtained from regression by matching experimental viscosity measurements. If no information is available, they are defaulted to vc. The mixture viscosity parameter is given by x i Tci i x i MWi i
1/ 2
1/ 6
x i p ci i
2/3
(2.11.3)
(x i MWi1 / 2 )
i
(2.11.4)
where i , the low pressure viscosities for pure substances are from the Stiel and Thodos (1961) equation:
0.618 * 2.04 exp( 0.449Tri ) i i = 4.610Tri
(2.11.5)
4
(2.11.6)
Appendix B 205
The parameter vci resembles the critical volume for component i. In fact for most usage v ci = v ci . The parameters and a0 through a4 are usually obtained by regressing the available data. If no viscosity information is available, the following values can be used: a0 a1 a2 a3 a4 = = = = = = 1 1.0230 x 10-1 2.3364 x 10-2 5.8533 x 10-2 -4.0758 x 10-2 9.3324 x 10-3
(2.12.1)
(k ) = J 1
( )( ) G ( )
k k
(2.12.2)
Quasi-Newton Successive Substitution (Nghiem and Heidemann, 1982): (k ) = (k )G (k ) (k ) = with (0 ) = QSTEP 1 and limited to DGM 30 m limited to DVMAX 6 (2.12.3) (k 1) G (k -1) (k 1) (k 1) G (k -1)
The QNSS method is restarted at every IREST iterations. Generally, IREST has the same magnitude as the total number of components.
206 Appendix B
Reservoir fluid analyses usually report composition of all light and intermediate components. Heavy components are lumped into a 'plus' fraction, e.g. C6+ where only the molecular weight and specific gravity are reported. It is advantageous to split the plus fraction into the single carbon number (SCN) fractions using model distribution e.g., C6, C7, ..., C45. The properties for each SCN are then estimated by empirical correlations. The synthetic distribution is then regrouped into a smaller number of hypothetical components (e.g., C6-C12, C13-C20, C21+) via mixing rules.
Distribution Model
A two-stage weighting exponential function is used as a probability function to describe the molar distribution as a function of molecular weight
x ci = with
MWi +1
dMW
MWi
The parameters Co, Mo are from the 'minus' fraction, the fraction immediately preceding the plus fraction. Co Mo = = Mole fraction of the minus fraction / 14.0 Molecular weight of the minus fraction
The parameter M1 and C1 are calculated by matching the molar distribution to the molecular weight and mole fraction of the plus fraction, X+ and M+ X+ =
dMW =
Mo
M1 e C1 e C1 e Co C1 C o C2
(M +
M o )X + =
2
Mo
M1 MWd(MW ) = C C o 1 (2.13.2)
Co C1 C o e 1 + (C1 C o 1)e
1 + C 2
Ci (1 C 2 M 1 )e
Appendix B 207
The parameter C2 is left as an adjustable parameter. It represents the final decline in the molar density function. The following equation was found to represent well the conventional oil in Canada: C2 C3 where A B C D E F G = = = = = = = 2.8297 x 10-3 4.0001 x 10-1 -8.4344 x 10-3 -6.3014 x 102 12.0 200.0 0.853 = =
- ln 10 / (14.C 3 )
A(M + - F) 2 + B(M + - F) + C(SG + - G) 2 + D(SG + - G) + E
and SG+ is the specific gravity of the plus fraction. It can be used when no other information is available.
Selection of Molecular Weight Range of SCN Group
The molecular weight range of each SCN group, say SCNi, is chosen to be between M1(i) = DERM(i-) and M2(i) = DERM(i+1-). The defaults are DERM = 14.026 and (bias) = 0.75.
Properties of Single Carbon Number Fraction
With the model distribution the mole fraction and molecular weight of each single carbon number (SCN) fraction, i, is easily calculated from the integral and the first moment: x ci =
M2
dMW 1 x ci
M2
(2.13.3)
M1
MWci =
MWdMW + M o
M1
The specific gravity and normal boiling point for the SCN fraction are calculated from the Hariu-Sage (1969) correlation and assuming a constant Watson's characterization factor, Kuop, which is adjusted to match the measured specific gravity of the plus fraction SG+: log10 (MWi )=
j= 0 2 k =0
j A jk Tbki K uop
208 Appendix B
where A00 A10 A20 A01 A11 A21 A02 A12 A22 = = = = = = = = = 0.6670202 4.583705 x 10-3 -2.698693 x 10-6 0.1552531 -5.755585 x 10-4 3.875950 x 10-7 -5.378496 x 10-3 2.500584 x 10-5 -1.566228 x 10-8
The critical properties of the SCN fractions are calculated using, for example, Twu's correlations.
Lumping into Hypothetical Components
Following Whitson (1983), the number of hypothetical components, NG, required to characterize a plus fraction is estimated as NG = 1 + 3.3 log10 (N-n) where n is the first SCN fraction in a Cn+ fraction and N is the SCN fraction corresponding to 95 mole % of a Cn+ fraction. The SCN fractions are then assigned to the hypothetical components according to their log (K) value. The K-values are calculated using the Wilson's equations. The Lee-Kesler (1975) mixing rules are then used to calculate the critical properties of the hypothetical components:
(1) = x j j
j
Vc(1) = Tc(1) =
1 8 j 1 8Vc
k j
1/ 3 1/ 3 x j x k Vcj + Vck
1/ 3 1/ 3 x j x k Vcj + Vck
Tcj Tck
Appendix B 209
START
For each fraction calculate Pci , Tci , wi by forcing EOS to match SGi , Tbi
Yes
No
Calculate NG
STOP
210 Appendix B
(2.14.2)
where
40 CN 12 = 40.3 CN > 12 CNi = MWi/14 (2.14.3)
CN is the carbon number of the component i given by (2.14.4) where MWi is the molecular weight of i. For multicomponent systems 1/4 = p ari (x i L y i V )
i =1 nc
(2.14.5)
where xi are the mole fractions in phase L and yi the mole fractions in phase V.
Regression
The major problem associated with phase-behavior matching with a cubic equation of state is the selection of regression parameters. There are many parameters that can be selected as the best set of parameters, and therefore a dynamic parameter-solution scheme is desired to avoid tedious and time-consuming trial-and-error regression runs. WinProp uses a regression technique where the most significant parameters are selected from a large set of parameters during the regression process. This reduces the regression effort considerably and alleviates the problem associated with the apriori selection of regression parameters (Agarwal, Li and Nghiem, 1987).
Introduction
It is well known that cubic equations of state (EOS) will not generally predict accurately laboratory data of oil/gas mixtures without the tuning of the EOS parameters (Coats and Smart, 1986). It has often been the practice to adjust the properties of the components (usually the heavy fractions, e.g. pc, Tc, , etc., to fit the experimental data.
Appendix B 211
The objective function of the regression involves the solution of complex nonlinear equations such as flash and saturation-pressure calculations. A robust minimization method is therefore required for rapid convergence to the minimum. In WinProp a modification of the adaptive least-squares algorithm of Dennis et al (1981) is used. The modification involves the use of some other nonlinear optimization concepts on direction and step-size selection due to Chen and Stadtherr (1981). The dynamic selection of the most meaningful regression parameters from a larger set of variables is described in Application of the Regression Method to EOS Tuning section. This feature is extremely useful in EOS fitting because it alleviates the problem of deciding apriori the best regression variables, which is extremely difficult. It should be stressed that the regression procedure will not correct the deficiencies of the EOS used, and the EOS predictive capability depends entirely on the type and the accuracy of the data used in the regression. For predictive purposes, attempts should be made to ensure that the "tuned" parameters are within reasonable physical limits.
(2.15.1)
where
x = [x 1 , x 2 ,..., x n t ]
T
is the regression-parameter vector, with nr being the number of regression parameters and nm the number of measurements to be fitted. Usually nm > nr. The elements of R(x) are denoted by ri (x) which are nonlinear in x. When the equation of state is adjusted to match a set of experimental data y
ri = e i (x ) y i yi
with
E(x ) = e1 (x ), e 2 (x ),..., e n m (x ) T
and
y = [y i , y 2 ,..., y n m ]
where E(x) are the equation-of-state results and y the experimental data points. In this case the nonlinear least-squares problem consists of adjusting x so that the EOS results match the experimental measurements.
212 Appendix B
The problem (2.15.1) may be solved by various methods for nonlinear parameter estimation (Bard, 1974), and for nonlinear optimization (Himmelblau, 1972; Schittkowski, 1981). The general purpose optimization methods however do not take advantage of the special structure of the nonlinear least squares optimization problem (2.15.1). Several strategies are available to exploit this structure. Coats and Smart (1986) used a modified linear programming least squares algorithm to solve (2.15.1). Watson and Lee (1986) use a modification of the Levenberg-Marquardt algorithm (see More', 1978) to solve a nonlinear least-squares problem. In WinProp a modification of the adaptive least-squares algorithm of Dennis et al (1981) is used. The algorithm departs from the method of Dennis et al in using some other nonlinear optimization concepts on step-direction and step-size selection due to Chen and Stadtherr (1981).
It was found that the key to an efficient algorithm would be the fast and accurate (as far as possible) estimation of the Jacobian matrix J. It has been shown that the matrix J also determines the second derivative Hessian matrix 2f. Consequently, a small change in the determination of J affects the performance of the regression method quite dramatically. The derivatives of the residuals R are calculated by numerical differentiation, since in most cases it is not practical to obtain exact analytical derivatives. The calculation of R at all times involves iterative processes, where the solution is only available to some accuracy i. If the Jacobian J is to be calculated by finite differences, the perturbation in the independent variables x must be such that it is not masked by the convergence accuracy i or the truncation and roundoff errors associated with the computation. It has been found that a perturbation of 1% in the independent variables is adequate to compute J by numerical differentiation.
Choice of Regression Parameters
Given a global set of regression parameters xj, j=1,...,np, the method selects an active subset of nr parameters with which regression will be performed. The global set of regression parameters is supplied by the user and may include any of the following parameters: pci Tci vci i vit MWi Critical pressure of Component i Critical temperature of Component i Critical volume of Component i which affects the interaction coefficients between hydrocarbons (see Equation 2.16.1) Acentric factor of Component i Volume translation of Component i (see Equations section) Molecular weight of Component i
Appendix B 213
dij
Interaction coefficient between Components i and j Exponents for computing interaction coefficients between hydrocarbons (see Equation 2.16.1)
The interaction coefficients between hydrocarbons are estimated from the following equation (Li, et al, 1985)
/ 6 1/ 6 2 v1 ci v cj d ij = 1 1 / 3 1/ 3 v ci + v cj
(2.16.1)
The volume translation technique of Peneloux et al (1982) is used to correct the molar volume (see Equations section). The parameters xj are scaled by using the upper bound xj,max and lower bound xj,min of the corresponding parameter such that they always lie between zero and unity. x j = (x j x j,min ) / (x j,max x j,min ) (2.16.2) The regression scheme sorts the np parameters in the descending order of |f / xj|. From these np parameters, the first nr parameters are chosen for regression, i.e. the nr parameters with the largest |f / xj|. nr is supplied by the user. The regression proceeds on these nr parameters and if at any time during the regression, |f / xj| becomes less than ri |, i=1,...,nm, the variable xj is dropped from the regression set and the next variable on the original sorted list is added on. Indeed, since all xj are scaled between zeros and unity, if |f / xj| is less than all |ri|, it is likely that xj has to go beyond its bounds to further reduce ri. Therefore, it is logical that xj should be dropped from the active parameter set. Another condition where xj is dropped is when it tries to go out of bonds for more than two iterations. At convergence, if the total number of regressed variables (including those which have been dropped) is less than five, then new variables are added to the active regression set and the original active regression variables with the smallest |f / xj| are removed from the active set such that nr is preserved. The flow chart of the parameter selection procedure is given in Figure B.2.
214 Appendix B
START
No
Yes
Drop x j from the active regression set. Add the next variable from the sorted list to the active set
No
Yes
STOP
Figure B.2: Flow Chart for Selecting the Active Regression Parameters
Appendix B 215
Properties of Components
The equations-of-state requires the critical properties as input. The critical properties for common single real molecules have been measured and tabulated in numerous handbooks. A fraction of the reservoir fluid, on the other hand, consists of numerous real molecules and generally only their specific gravity, boiling point and molecular weights are measured. Their critical properties are not determined. The components making up the reservoir fluid are thus identified into two types: the built-in components and the user components. Built-in components are those whose critical properties are known and have been stored in the phase behavior package WinProp. User components are those whose properties are not stored and must be supplied as input to WinProp.
Real Components Component p c, atm. v c, l/gmole Tc, deg. K acentric factor MW, g/mol
CH4 C2H6 C3H8 iC4 nC4 iC5 nC5 nC6 nC7 nC8 nC9 nC10 nC16 N2 CO2 H2S H2O Toluene Benzene Cyclo-C6 FC6 FC7 FC8 FC9 FC10 FC11 FC12
216 Appendix B
45.400 48.200 41.900 36.000 37.500 33.400 33.300 29.300 27.000 24.500 22.800 20.800 14.000 33.500 72.800 88.200 217.60 40.600 48.300 40.200 32.460 30.970 29.120 26.940 25.010 23.170 21.630
0.0990 0.1480 0.2030 0.2630 0.2550 0.3060 0.3040 0.3700 0.4320 0.4920 0.5480 0.6030 0.9560 0.0895 0.0940 0.0985 0.0560 0.3160 0.2590 0.3080 0.3440 0.3810 0.4210 0.4710 0.5210 0.5740 0.6260
190.60 305.40 369.80 408.10 425.20 460.40 469.60 507.40 540.20 568.80 594.60 617.60 717.00 126.20 304.20 373.20 647.30 591.70 562.10 553.40 507.50 543.20 570.50 598.50 622.10 643.60 663.90
0.00800 0.09800 0.15200 0.17600 0.19300 0.22700 0.25100 0.29600 0.35100 0.39400 0.44400 0.49000 0.74200 0.04000 0.22500 0.10000 0.34400 0.25700 0.21200 0.21300 0.26370 0.30240 0.33720 0.37810 0.41650 0.45530 0.49220
16.04300 30.07000 44.09700 58.12400 58.12400 72.15100 72.15100 86.17800 100.2050 114.2320 128.2590 142.2860 226.4480 28.01300 44.0100 34.0800 18.01500 92.14100 78.11400 84.16200 86.0000 96.0000 107.0000 121.0000 134.0000 147.0000 161.0000
Component
pc , atm.
vc, l/gmole
Tc, deg. K
acentric factor
MW, g/mol
FC13 FC14 FC15 FC16 FC17 FC18 FC19 FC20 FC21 FC22 FC23 FC24 FC25 FC26 FC27 FC28 FC29 FC30 FC35 FC36 FC37 FC38 FC39 FC40 FC41 FC42 FC43 FC44 FC45
20.430 19.330 18.250 17.150 16.350 15.650 15.060 14.360 13.830 13.260 12.830 12.380 11.840 11.480 11.130 10.760 10.490 06.310 09.910 08.660 08.530 08.290 08.130 07.900 07.780 07.600 07.460 07.250 07.140
0.6740 0.7230 0.7770 0.8350 0.8840 0.9300 0.9730 1.0270 1.0730 1.1260 1.1700 1.1510 1.2020 1.2400 1.2790 1.3230 1.3560 2.0060 1.5890 1.6320 1.6570 1.7020 1.7340 1.7800 1.8060 1.8440 1.8780 1.9280 1.9550
682.40 700.70 718.60 734.50 749.20 760.50 771.00 782.90 793.30 804.40 814.00 823.20 832.70 841.20 849.60 857.70 864.30 832.80 905.90 912.10 917.30 923.40 928.20 934.30 938.50 942.80 947.60 953.70 957.80
0.52480 0.55720 0.58990 0.62250 0.64960 0.67240 0.69280 0.71670 0.73610 0.75690 0.77350 0.93510 0.96690 0.99090 1.01450 1.03960 1.05850 1.23760 1.17720 1.19660 1.20850 1.22780 1.24120 1.26020 1.27070 1.28560 1.29880 1.31730 1.32750
175.0000 190.0000 206.0000 222.0000 237.0000 251.0000 263.0000 275.0000 291.0000 300.0000 312.0000 324.0000 337.0000 349.0000 360.0000 372.0000 382.0000 394.0000 445.0000 456.0000 464.0000 475.0000 484.0000 495.0000 502.0000 512.0000 521.0000 531.0000 539.0000
The properties for the first 20 are obtained from Reid et al (1977). The next 30 components, FC6 to FC45 represent typical hydrocarbon fractions C6 to C45. Their critical properties are calculated with the correlations of Kesler and Lee (1976), using the averaged normal boiling points and specific gravities of C6 to C45 reported by Whitson (Whitson, 1983; Katz and Firoozabadi, 1978). These components can be used for rough calculations if no other information about the heavy ends are available.
Appendix B 217
User Components
For User components, usually only the physical properties molecular weight, boiling point and/or specific gravity are known. The critical properties are calculated from empirical correlations. Numerous such correlations are available in the literature. A survey by Whitson (1982) suggested the use of Kesler-Lee correlations for conventional oil. For heavy hydrocarbons the correlation of Twu (1984) generally yields reasonable results (Fu et al, 1986). These two methods are available in WinProp to calculate the required critical properties. In view of its simplicity, the method of Riazi-Daubert is also available. The correlations are summarized below.
Kesler and Lee (1976)
ln p c +
( ( (
= 8.3634 0.0566 SG 0.24244 + 2.2898 / SG + 0.11857 / SG 2 10 3 Tb 1.46850 + 3.6480 / SG + 0.47227 / SG 2 10 7 Tb2 3 0.42019 + 0.0000 / SG + 1.69777 / SG 2 10 10 Tb
) ) )
Tc = 341.7 + 811 SG + (0.4244 + 0.1174 SG ) Tb + (0.4669 3.2623 SG )10 5 / Tb For > 0.8
2 = 7.904 + 0.1352 K c 0.007465 K c + 8.359 + (1.408 0.01063 K ) /
For < 0.8 = where p c in psia Tb , Tc in o R = Tb / Tc 1/ 3 K c = (CABP) / SG CABP = cubic average boiling point in o R
Twu (1984)
(2.17.1)
SG T = exp 5 SG o SG 1 1
[(
)]
218 Appendix B
[(
)]
f p = SG p
[( 2.53262 46.1955 / T
[ (
)]
) (V
o c
/ Vco
) [( 1 + 2 f ) / ( 1 2 f )]
p p
1/ 2 b
0.00127885 Tb
[ x + ( 0.0175691 + 0.193168 / T ) SG ]
M
1/ 2 x = 0.0123420 0.328086 / Tb
[(
)]
( = (3.83354 + 1.19629
3 13 0.284376 x 10 10 Tb + 0.959468 x 10 28 / Tb
Tb = exp ( 5.71419 + 2.71579 0.286590 2 39.8544 / - 0.122488 / 2 ) - 24.7522 + 35.3155 2 with = ln MW o = 1 Tb / Tco (2.17.2)
Appendix B 219
p c = 3.12281 x 10 9 T
2.315 b
SG
2.3201
.58848 Tc = 24.2787 T 0 SG b
0.3596
Interaction Coefficient
The importance of interaction coefficients, dij, in the accuracy of phase behavior calculations, especially the saturation pressures, has been demonstrated by Peng and Robinson (1976), Conrad and Gravier (1980) and Whitson (1982) among others. Theoretically, dij is introduced to account for the molecular interaction between dissimilar molecules. Their values are usually obtained by fitting the predicted saturation pressure curves to experimental data.
Hydrocarbon-Hydrocarbon Interaction
Katz and Firoozabadi (1978) have published the binary interaction coefficients between methane and other heavy hydrocarbon fractions. Their values have been fitted to the density, , of the fraction by Conrad and Gavier (1980) as: d = 0.12903 - 0.05871 Whitson and Torp (1981) have fitted the same set of data using specific gravity, SG, as correlating parameters: d = 0.14 (SG) - 0.0668 The Institute of Thermodynamics (Technical University of Berlin) has accumulated a comprehensive collection of data on vapor-liquid equilibrium. It contains approximately 55,000 experimental data for more than 120 binary systems. These have been evaluated by Oellrich, Plocker, Prausnitz and Knapp (1981) to determine the interaction coefficients (both hydrocarbon and non-hydrocarbon systems) for the commonly used equations-of-state including PR and SRK. Mehra (1981) and Li (1983) both used the following relations for hydrocarbon-hydrocarbon systems:
2 V1 / 3 V1 / 3 ci cj d ij = 1 1 / 3 1/ 3 Vc + Vc i j
n
(2.18.1)
with the constant n = 1. The same form is also proposed by Chueh and Prausnitz (1967) and Chaudron, Asselineau and Renon (1973). Examining the paraffin-paraffin dij of Oellrich et al (1981) shows that they could roughly be correlated using this equation with n = 1.2. Mehra (1981) has also shown that this equation reproduces satisfactorily the methane interaction coefficients of Katz and Firoozabadi (1978). Equation (2.18.1) is used in WinProp with n as a user input parameter.
220 Appendix B
Hydrocarbon-Nonhydrocarbon Interaction
Besides Oellrich et al (1981), other researchers have also reported values of interaction coefficients for hydrocarbon-nonhydrocarbon systems. The reported interaction coefficient values between CO2 and hydrocarbons, dCO2-HC, generally ranges from 0.1 to 0.13 for PR EOS (Oellrich et al, 1981; Hughes, Matthews and Mott, 1981; Katz and Firoozabadi, 1978; Mehra, 1981). In addition, dCO2-HC correlations have been proposed by Kato, Nagahama and Hirata (1981); Mulliken and Sandler (1980) and Turek, Metcalfe, Yarborough and Robinson (1980). These correlations are generally temperature dependent and complicated. The reported interaction coefficient values between N2 and hydrocarbons, dN2-HC, generally increases with increasing carbon number in the hydrocarbon, and range from 0.03 to 0.15 (Mehra, 1981; Oellrich et al, 1981; Katz and Firoozabadi, 1978). The following table shows the interaction coefficients for nonhydrocarbons stored in WinProp.
N2 CO2 H2S H2O
CH4 C2H6 C3H8 iC4 nC4 iC5 nC5 nC6 nC7 nC8 nC9 nC10 nC16 Toluene Benzene Cyclo-hexane FC6-FC45 N2 CO2 H2S H2O
.031 .042 .091 .095 .095 .095 .095 .100 .100 .100 .100 .100 .130 .120 .120 .120 .120 .000 -.020 .176 .275
.103 .130 .135 .130 .130 .125 .125 .125 .120 .115 .110 .110 .090 .120 .078 .106 .150 -.020 .000 .096 .200
.080 .070 .070 .060 .060 .060 .060 .050 .040 .040 .030 .000 .000 .000 .000 .000 .000 .176 .096 .000 .120
.4907 .4911 .5469 .5080 .5080 .5000 .5000 .4500 .4500 .4500 .4500 .4500 .4500 .4800 .4800 .4800 .4800 .2750 .2000 .1200 .0000
Appendix B 221
Nomenclature
a b c Cp dij D fi F Fj G GOR hij Hi Hspec Ki Kij L1 L2 MW n N Nc Np NHYP p ri R T T3p ui U v V xi X zi Z equation of state parameter equation of state parameter equation of state parameter heat capacity interaction coefficient stability test distance fugacity for component i degree of freedom from the phase rule mole fraction of phase j Gibb's free energy gas-oil ratio partial molar enthalpy of component i in phase j enthalpy, or Henry's law constant for water flash for component i specified molar enthalpy equilibrium ratio for component i equilibrium ratio for component i in phase j first liquid phase second liquid phase molecular weight mole number total number of moles total number of components number of phases number of hypothetical components pressure volume translation for component i universal gas constant temperature three phase temperature number of component i in stability test vector of u partial molar volume vapor phase phase composition of component i, mole fraction vector of x global composition of component i, mole fraction compressibility factor (pv/RT)
222 Appendix B
critical property component number component number, phase phase liquid phase 1 liquid phase 2 reference phase for component i vapor phase water phase
excess property iteration number liquid phase 1 non-translated volume liquid phase 2 translated volume vapor phase water phase ideal state, reference state
equation of state parameters equation of state parameters fugacity coefficient equation of state parameter equation of state parameter acentric factor specified variables for phase diagram construction fraction of injection fluid for phase diagram construction viscosity mixture viscosity parameter reduced density density
Appendix B 223
Himmelblau, D.M., "Applied Nonlinear Programming," McGraw-Hill Inc., 1972. Hughes, D.S., Matthews, J.D., and Mott, R.E., "Theoretical Aspects of Calculating the Performance of CO2 as an EOR Process in North Sea Reservoirs," Proceedings, 1981 European Symposium on EOR, September 21-23, 1981, Bournemouth, England. Jhaveri, B.S., and Youngren, G.K., "Three-Parameter Modification of the Peng-Robinson Equation of State to Improve Volumetric Predictions," SPE paper 13118, presented at the 59th Annual Technical Conference and Exhibition, Houston, Texas, September 16-19, 1984. Kato, K., Nagahama, K., and Hirata, M., "Generalized Interaction Parameters for the PengRobinson Equation of State: Carbon Dioxide-n-Paraffin Binary Systems," Fluid Phase Equil., Vol. 7, 1981, pp. 219-231. Katz, D.L., and Firoozabadi, A., "Predicting Phase Behavior of Condensate/Crude-Oil Systems Using Methane Interaction Coefficients," J. Petrol. Technol., Vol. 30, 1978, pp. 1649-1655. Kesler, M.G., and Lee, B.I., "Improve Predictions of Enthalpy of Fractions," Hydro. Proc., March 1976, pp. 153-158. Lee, B.I., and Kesler, M.G., "A Generalized Thermodynamic Correlation Based on ThreeParameter Corresponding States," AIChE J., Vol. 21, May 1975, pp. 510-527. Li, Y.-K., and Nghiem, L.X., "The Development of a General Phase Envelope Construction Algorithm for Reservoir Fluid Studies," paper SPE 11198, presented at the 57th Annual Fall Meeting of SPE-AIME, September 26-29, 1982, New Orleans, Louisiana. Li, Y.-K., "Heavy Fraction Characterization and Hypothetical Component Selection for Oil and Gas Mixtures," Computer Modelling Group Research Report R12.04, May 1983. Li, Y.-K., and Nghiem, L.X., "Phase Equilibria of Oil, Gas and Water/Brine Mixtures from a Cubic Equation of State and Henry's Law," Can. J. Chem. Eng., 1986. Li, Y.-K., Nghiem, L.X., and Siu, A., "Phase Behavior Computations for Reservoir Fluids: Effects of Pseudo-Components on Phase Diagrams and Simulation Results," J. Can. Pet. Tech., Vol. 24, No. 6, 1985, pp. 29-36. Martin, J.J., "Cubic Equations of State - Which?," Ind. Eng. Chem. Fundam., Vol. 18, No. 2, 1979, pp. 81-97. Mehra, R.K., "The Computation of Multi-Phase Equilibrium in Compositional Reservoir Studies," Ph.D., Thesis, University of Calgary, 1981. Mehra, R.K., Heidemann, R.A., and Aziz, K., "An Accelerated Successive Substitution Algorithm, "Can. J. Chem. Eng., Vol. 61, 1984, pp. 590-596. Michelsen, M.L., "Calculation of Phase Envelopes and Critical Points for Multicomponent Mixtures," Fluid Phase Equilibria, Vol. 4, 1980, pp. 1-10. Michelsen, M.L., and Heidemann, R.A., "Calculation of Critical Points from Cubic TwoConstant Equations of State," AIChE J., Vol. 27, No. 3, 1981, pp. 521-523. Michelsen, M.L., "The Isothermal Flash Problem, Parts I and II," Fluid Phase Equilibria, Vol. 9, 1982, pp. 1-40.
Appendix B 225
Moore, J.J., "The Levenberg-Marquardt Algorithm: Implementation and Theory," In Lecture Notes in Mathematics, No. 630, Numerical Analysis, G. Watson, Ed., Springer-Verlag, New York, 1978, pp. 105-116. Mulliken, C.A., and Sandler, S.I., "The Prediction of CO2 Solubility and Swelling Factors for Enhanced Oil Recovery," Ind. Eng. Chem. Process Des. Dev., Vol. 19, 1980, pp. 709-711. Nghiem, L.X., and Heidemann, R.A., "General Acceleration Procedure for Multiphase Flash Calculation With Application to Oil-Gas-Water Systems," paper presented at the 2nd European Symposium on Enhanced Oil Recovery, Paris, France, November 8-10, 1982. Nghiem, L.X., Aziz, K., and Li, Y.-K., "A Robust Iterative Method for Flash Calculations Using the Soave-Redlich-Kwong or Peng-Robinson Equation of State," Soc. Petrol. Eng. J., Vol. 23, June 1983. Nghiem, L.X., and Li, Y.-K., "Computation of Multiphase Equilibrium Phenomena of Reservoir Fluid," Fluid Phase Equil., Vol. 17, 1984, pp. 77-95. Nghiem, L.X., Li, Y.-K., and Heidemann, R.A., "Application of the Tangent Plane Criterion to Saturation Pressure and Temperature Computations," Fluid Phase Equil., Vol. 21, 1985, pp. 39-50. Oellrich, L., Plocker, U., Prausnitz, J.M., and Knapp, H., "Equation-of-State Methods for Computing Phase Equilibria and Enthalpies," Int. Chem. Eng., Vol. 21, No. 1, January 1981, pp. 1-15. Passut, C.A., and Danner, R.P., "Correlation of Ideal Gas Enthalpy, Heat Capacity, and Entropy," Ind. Eng. Chem. Process Des. Develop., Vol. 11, No. 4, 1972, pp. 543-546. Peneloux, A., Rauzy, E., and Freze, R., "A Consistent Correction for Redlich-Kwong-Soave Volumes," Fluid Phase Equil., Vol. 8, 1982, pp. 7-23. Peng, D.Y., and Robinson, D.B., "A New Two-Constant Equation of State," Ind. Eng. Chem. Fundam., Vol. 15, 1976, pp. 59-64. Reid, R.C., Prausnitz, J.M., and Sherwood, T.K., The Properties of Gases and Liquids, 3rd Edition, McGraw-Hill, New York, 1977. Riazi, M.R., and Daubert, T.E., "Simplify Property Predictions," Hydrocarbon Processing, March 1980, pp. 115-116. Robinson, D.B, and Peng, D.Y., "The Characterization of the Heptanes and Heavier Fractions for the GPA Peng-Robinson Programs," Gas Processors Association, Research Report RR28, March 1978. Rowe, A.M., and Chou, J.C.S., "Pressure-Volume-Temperature-Concentration Relation of Aqueous NaCl Solutions," J. Chem. Eng. Data, Vol. 15, No. 1, 1970, pp. 61-66. Schittkowski, K., "The Nonlinear Programming Method of Wilson, Han, and Powell with an Augmented Lagrangian Type Line Search Function - Parts I and II," Numer. Math, Vol. 38, 1981, pp. 83-127. Soave, G., "Equilibrium Constants from a Modified Redlich-Kwong Equation of State," Chem. Eng. Sci., Vol. 27, 1972, pp. 1197-1203. Stiel, L.I., and Thodos, G., "The Viscosity of Nonpolar Gases at Normal Pressures," AIChE J., Vol. 7, No. 4, 1961.
226 Appendix B User's Guide WinProp
Twu, C.H., "An Internally Consistent Correlation for Predicting the Critical Properties and Molecular Weights of Petroleum and Coal-Tar Liquids," Fluid Phase Equil., Vol. 16, 1984, pp. 137-150. Turek, E.A., Metcalfe, R.S., Yarborough, L., and Robinson, R.L. Jr., "Phase Equilibria in Carbon Dioxide - Multicomponent Hydrocarbon Systems: Experimental Data and an Improved Prediction Technique," paper SPE 9231, presented at the 55th Annual Fall Meeting of SPE-AIME, September 21-24, 1980, Dallas, Texas. Watson, A.T., and Lee, W.J., "A New Algorithm for Automatic History Matching Production Data," paper SPE 15228, presented at the Unconventional Gas Technology Symposium of SPE, Louisville, Kentucky, May 18-21, 1986. Whitson, C.H., "Effect of Physical Properties Estimation on Equation-of-State Predictions," SPE paper 11200, presented at the 57th Annual Fall Technical Conference of SPE-AIME, September 26-29, 1982, New Orleans, Louisiana. Whitson, C.H., "Characterizing Hydrocarbon Plus Fractions," SPEJ, Vol. 23, No. 4, August 1983, pp. 683-694. Whitson, C.H., "Critical Properties Estimation from an Equation of State," SPE/DOE paper 12634, presented at the SPE/DOE Fourth Symposium on Enhanced Oil Recovery, Tulsa, Oklahoma, April 15-18, 1984.
Appendix B 227