Sheet No A&A Works for 6 Knutsford Terrace Existing Checking Prepared Chk By
Dwg Ref
Rev No
Date 05-13-2013
Check Slab
Reinforcement Grade = 460 3.00 Tensile stress other than in shear reinforcement, pst = 230.00 Breath b = 1000.00 Effective Depth, d1 = 95.00 Short Span, Lx = 1940 Long Span, Ly = 3000 Loading DL =
= = = LL = Total Load, w =
Bending Moment Coefficient Interior Panels 1 Aspect Ratio = Ly/Lx = 1.55 Span = Short x -ve Moment = 0.061 +ve Moment = 0.047 Existing Reinforcement Provided Short Span Top Bar = Bottom Bar = Long Span Top Bar = Bottom Bar = Check Reinforcement Short Span -ve Moment = +ve Moment = Long Span -ve Moment = +ve Moment = Mlong 1.83 1.38 Mr 26.40 26.40 Mshort 3.37 2.60 Mr 26.40 26.40 T T T T
10 10 10 10
mm mm mm mm -
R 0.37 0.29
a 0.98 0.98
R 0.20 0.15
a 0.99 0.99
OK OK