Professional Documents
Culture Documents
Concrete Sleepers (Medium Duty) - Design: Discipline: Engineering (Track & Civil) Category: Standard
Concrete Sleepers (Medium Duty) - Design: Discipline: Engineering (Track & Civil) Category: Standard
Category:
Standard
Primary Source
RIC Standard C 3109 Version 3.1/TDS 01 Draft Version 2.0 Jul 05, AS 1085.14 - 2003
Document Status
Version
2.1
Date Reviewed
05 Jan 07
Prepared by
Standards & Systems
Reviewed by
Standards & Systems
Endorsed
Standards & Technical Services Engineer
Approved
Manager Standards & Systems 05/01/2007
Amendment Record
Version
1.0
Date Reviewed
13 Jan 06
Clause
Various
Description of Amendment
Amended to suit Medium Duty concrete sleepers. Issued as Common Standard ETD-02-01 (supersedes NSW Standard TDS 01 Prestressed Concrete Sleepers Design Version 1.2) Requirement for ballast interlocking features on the sides of sleepers and the twin-block sleeper option removed Addition of text regarding tolerances for track gauge for new rail
2.0 2.1
ARTC. This document is the confidential property of Australian Rail Track Corporation.
Disc laimer This document is for internal use by the Australian Rail Track Corporation LTD (ARTC) only and may not be relied upon by any other party. ARTC: 1. does not accept any liability or responsibility whatsoever for this document in respect to any use or reliance upon it by any other party; and 2. does not provide any warranty as to the accuracy or reliability of this document.
This document is uncontrolled when printed. See ARTC Intranet for latest version.
Engineering (Track & Civil) Standard ETD-02-01 Concrete Sleepers (Medium Duty) - Design Contents
Contents
1 2 3 4 General Description ................................................................................ 3 Definitions .............................................................................................. 3 References.............................................................................................. 3 Design Requirements.............................................................................. 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 5 6 7 8 General ............................................................................................ 4 Track Details ..................................................................................... 4 Sleeper Dimensions............................................................................ 5 Design Parameters ............................................................................. 5 Installation, Handling and Maintenance................................................. 5 System Performance .......................................................................... 5 Allowance for Retrofit ......................................................................... 5
Sleeper Marking ...................................................................................... 6 Product Approval Requirements ............................................................. 6 Previous Installation Experience ............................................................ 6 Sleeper Performance and Tests in Accordance with AS 1085.14 ............. 7
Version 2.1
Date of last revision: 05 Jan 07 This document is uncontrolled when printed. See ARTC Intranet for latest version.
Page 2 of 7
Engineering (Track & Civil) Standard ETD-02-01 Concrete Sleepers (Medium Duty) - Design General Description
General Description
This Standard details requirements for the design of concrete sleepers having resilient fastenings and insulators designed in accordance with ARTC Standard ETD-02-02 for use on track having nominal 25 t axle load or less. Concrete sleepers supplied for use in Australian Rail Track Corporation track shall meet these design requirements. Concrete sleepers for special applications including multi-gauge tracks and turnout bearers are not covered by this Standard.
Definitions
Concrete sleeper A sleeper consisting of appropriately formed reinforced concrete which, when prestressed, includes the deformed reinforcing bars (tendons) which are stressed before casting the concrete. A component that prevents lateral movement of the rail foot and provides anchorage for the resilient fastening system. Elastic steel clips attached to sleepers and designed to engage rail flanges. These clips fasten rails to the sleepers providing lateral support. Standard resilient fastenings also generate toe load at the rail flange providing resistance to longitudinal movement, rail roll and rail lateral shift. Standard concrete sleeper cast in a single piece. Pertains to track having traffic not exceeding nominal 25 t axle loads nor more than 25 MGT annual traffic.
References
The design shall be based on relevant Australian Standards and Codes of Practice and/or the referenced standards specified in this document. Referenced Standards include: AS 1085.14 Prestressed Concrete Sleepers AS 1085.19 Resilient fastening assemblies AS 1085.1 Rails ARTC Standard ETD-02-02 Resilient Rail Fastenings for Medium Duty Concrete Sleepers Design ARTC NSW Standard TDS 09 Mainline Track Geometry. ARTC NSW Standard TDS 13 Base Operating Condition Standards of Track Geometry ARTC NSW Standard TEP 01 Evaluation & Approval of Track Components Other internationally accepted and proven standards providing these are at least equivalent to AS 1085.14. All references relate to the latest Standard versions, including amendments and relevant superseding Standards.
Version 2.1
Date of last revision: 05 Jan 07 This document is uncontrolled when printed. See ARTC Intranet for latest version.
Page 3 of 7
Engineering (Track & Civil) Standard ETD-02-01 Concrete Sleepers (Medium Duty) - Design Design Requirements
4
4.1
Design Requirements
General
Sleepers shall be monoblock type cast as pretensioned concrete Medium Duty for general use with axle loads up to 25 tonne. The design shall be in accordance with AS 1085.14 and/or the referenced standards unless otherwise specified in this document. Designs shall be checked by an independent competent organisation. Fastenings, cast in shoulders, pads, spacers and insulators shall comply with ARTC Standard ETD-02-02.
4.2
Track Details
The sleeper will be used on mainline track of 1435mm track gauge (measured 16 mm from the top of rail when assembled), assuming AS 1085, 47, 50, 53 or 60 kg/m rails or UIC 60 or UIC 54 rails are utilised. All running rails shall slope towards the track centre-line at 1 in 20. Tolerances for track gauge only apply to NEW rail. The following tolerances are applicable for medium duty concrete sleepers: AS53/60kg/m rail = +4mm wide gauge, -2mm tight gauge (+4, -2) AS47kg/m rail = +6mm wide gauge, 0mm tight gauge (+6, 0) The railways on which the sleepers will be used include extensive lengths of sharp curves and steep gradients where sanding is applied for improved traction. Concrete sleepers are to be designed to minimise potential for soffit abrasion and rail seat erosion in this type of operating environment. Track configuration is detailed in ARTC NSW Standard TDS 09, Class 1C track, with geometry maintained as per ARTC NSW Standard TDS 13. Sleepers will be installed in track both with and without signalling circuits and with and without electrification at 1.5 kV DC and may in future be electrified at 25 kV AC. Nominal maximum train speeds and loads may apply as detailed in Table 1.
Track geometry assumptions (curvature, gradient, superelevation, cant deficiency etc) are to be in accord with Table 2, TDS 09 Mainline Track Geometry for Class 1C track, except Max Ea may be 150 mm and Max D may be 130 mm for all XPT, Freight and Passenger. Other relevant track data includes: Electrical Insulation - Sleeper fastening assemblies and sleepers shall ensure a minimum electrical resistance between the running rails of 10 Ohms per track kilometre. Sleepers shall be designed and manufactured to provide a minimum service life of fifty years based on annual tonnage of 25 MGT, nominal axle load of 25 t and 667 mm nominal sleeper centres. Rail seat pads and insulators shall be designed and manufactured to provide a minimum service life as required in ARTC Common Standard ETD- 02-02 for this operating environment.
Version 2.1
Date of last revision: 05 Jan 07 This document is uncontrolled when printed. See ARTC Intranet for latest version.
Page 4 of 7
Engineering (Track & Civil) Standard ETD-02-01 Concrete Sleepers (Medium Duty) - Design Design Requirements
4.3
Sleeper Dimensions
Sleepers shall be designed to a preferred length of 2.5 m, a maximum depth at the rail seat of 250 mm and a width that provides a maximum pressure on ballast of 500 kPa when calculated in accordance with AS 1085.14. The width of the top of concrete sleepers at rail seats shall be not less than 160 mm plus any chamfer or rounding, or such greater width as may be required for specific pads (refer ETD-0202). The sleeper base surface shall be rough cast while the top and side surfaces shall be smooth to prevent retention of moisture and foreign material. Existing sleepers are typically 250mm wide at the base. This dimension is preferred but variations will be considered.
4.4
Design Parameters
Design parameters for the calculation of minimum sleeper capacity are as generally detailed in AS 1085.14, except that, in clause 4.2.3, the multiple of the impact factor, j, and the static wheel load, Q, shall be 250 kN. The load distribution factor shall be determined in accordance with Figure 4.1 of AS 1085.14 unless agreed otherwise.
4.5
4.6
System Performance
System performance requires the concrete sleeper assembly to function as part of the track structure. The sleeper must be able to transfer all the relevant track forces generated by train operations and the forces of rail thermal expansion and contraction to the ballast. The thermal expansion and contraction forces act on the continuously welded rails with a temperature range from approximately 10 C to 65 C about a nominal neutral temperature in the range of 25 C to 45 C. Design neutral temperature is typically 35 C to 38 C. Pads must possess sufficient edge stiffness to prevent the sleeper tilting (about its longitudinal axis) in order to resist longitudinal track forces arising from thermal expansion, contraction and rail creep. Pads shall be high-attenuation type as detailed in ARTC Common Standard ETD-0202. Clips must provide enough deflection capacity to accommodate rail movement on the pad indefinitely without loss of toe load.
4.7
Version 2.1
Date of last revision: 05 Jan 07 This document is uncontrolled when printed. See ARTC Intranet for latest version.
Page 5 of 7
Engineering (Track & Civil) Standard ETD-02-01 Concrete Sleepers (Medium Duty) - Design Sleeper Marking
Sleeper Marking
The following marks shall be displayed on each sleeper, with markings being raised or indented to suit the manufacturer. Note that some are mandatory and some are optional: Mark of Manufacturer (Optional) The letters ARTC (Optional) Year of manufacture (Mandatory) Batch number (including a design type designator) (Mandatory)
Lettering and marks shall be on the upper sleeper surface between rail seats.
Independent design check of the design shall be undertaken by a competent designer, and details of this design check and information shall be provided. Two sets of fully detailed drawings are to be supplied for each combination of sleeper type, fastening assembly and rail size. The drawing shall detail the following: Sleeper and fastening system dimensions including tolerances. Tendon type, size, material, number and location. Cast in Shoulder type, detail and material. Concrete mixture specification and properties.
The supplier will also be required to provide documentation of testing outcomes as specified in Section 7 and 8 below.
Version 2.1
Date of last revision: 05 Jan 07 This document is uncontrolled when printed. See ARTC Intranet for latest version.
Page 6 of 7
Engineering (Track & Civil) Standard ETD-02-01 Concrete Sleepers (Medium Duty) - Design Sleeper Performance and Tests in Accordance with AS 1085.14
d) Sleeper design information: i. ii. iii. iv. v. Refer to section 4.4 above. Refer to section 4.2 above. The preferred sleeper dimensions are set out in Section 4.3. The cross-sectional dimensions shall be determined such as to meet the requirements of section 4 above. The positive and negative moments shall be determined in accordance with section 4 of AS1085.14. Other design requirements are identified in section 4 above and ARTC Standard ETD02-02 and references and amendments thereto.
e) Fastening design information: (i) and (ii) refer to ETD-02-02 and references and amendments thereto. f) A general description of manufacturing procedures shall be provided.
Version 2.1
Date of last revision: 05 Jan 07 This document is uncontrolled when printed. See ARTC Intranet for latest version.