You are on page 1of 57

DIFFERENCE BETWEEN RNC 3810 AND

By-

Mohit Kumar
EILL 7598 mohit.kumar@ericsson.com

3810 AND RNC 3820

RNC 3810
Consists of one or two cabinets. Each cabinet contains one to three sub racks. Has one MS, located in the Main Cabinet. The capacity of the RNC is increased by connecting ESs to the MS. built on a common platform and connected in a star topology Maximum ES that can be connected = 5 (F configuration)

A - Power Connections B - Extension Subracks C - Main Subracks D - ICF - Interface connection field Configurations A - 1 MS B - 1 MS + 1 ES C - 1 MS + 2 ES D - 1 MS + 3 ES E - 1 MS + 4 ES F - 1 MS + 5 ES

2 SPB

O-pac 1 GPB

RNC 3820
Consists of one cabinet A cabinet contains one to three subracks. An RNC has one MS located at the bottom of the cabinet. The capacity of the RNC is increased by connecting ESs to the MS. built on a common platform and connected in a star topology Maximum ES that can be connected = 2

A - Extension Subrack B - Main Subrack C - APP - Active Patch Panel

Configurations A - 1 MS B - 1 MS + 1 ES C - 1 MS + 2 ES

C-pack - Capacity Card Package 1 GPB board 2 SPB boards

O-pack - Optimization Card Package 1 GPB board

The hardware structure remains same for both the RNC's

RNC 3810

RNC Hardware Structure Multiple Subracks

RNC 3820

RNC 3820 Hardware Structure Multiple Subracks

SXB is not present in RNC 3820

An RNC always includes an MS. The MS interconnects all other subracks in the RNC and includes all functions of an ES as well as functions common to the RNC

RNC 3810
MS Functions
Termination of the Mur interface with OSS-RC Termination of the Iu interface with the CN Termination of the Iur interface with another RNC Termination of the Iub interface with the RBSs Distribution of broadcast information to all involved subracks Distribution of broadcast information to all involved RBSs within subrack External transmission interfaces Attachment of synchronization sources Duplicated non-blocking Cell switch Duplicated high-speed links to interconnect with the ESs Duplicated timing signals for the node Input for GPS signals Pool of processors for user plane processing and control

ES Functions
Termination of the Iub interface with the RBSs Distribution of broadcast information to all involved RBSs within subrack External transmission interfaces Duplicated high-speed links between subracks and the MS Duplicated non-blocking Cell switch Pool of processors for user plane processing and control

RNC Modules
One General Purpose Processor Board (GPB) A set of dynamically allocated Special Purpose Processor Modules (SPMs) A set of semi-static allocated Iub Links, that is connections to RBSs Supporting software

LEGEND -

RNC 3820
MS Functions
Termination of the Mur interface with OSS-RC Termination of the Iu interface with the CN Termination of the Iur interface with another RNC Termination of the Iub interface with the RBSs Distribution of broadcast information to all involved subracks Distribution of broadcast information to all involved RBSs within a subrack External transmission interfaces Attachment of synchronization sources Duplicated non-blocking cell switch Duplicated high-speed links to interconnect with the ESs Duplicated timing signals for the node Input for GPS signals Pool of processors for user plane processing and control

ES Functions
Termination of the Iub interface with the RBSs Distribution of broadcast information to all involved RBSs within subrack External transmission interfaces Duplicated high-speed links between subracks and the MS Duplicated non-blocking Cell switch Pool of processors for user plane processing and control Termination of the Iu interface with the CN

RNC Modules
One General Purpose Processor Board (GPB) A set of dynamically allocated Special Purpose Processor Modules (SPMs) A set of semi-static allocated Iub Links, that is connections to RBSs Supporting software

SAME DIFFERENT

Subrack
Equipment
The MS and ES can each house up to 28 boards

RNC 3810

SLOT NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

RNC 3810
SCB3 SXB(m) SXB(r) TUB(m) TUB(r) ET/DUMMY ET/DUMMY GPB (m) GPB(r) GPB(m) GPB(r) GPB (m) GPB (r) GPB GPB

FUNCTIONALITY Power IN , 4 ports to connect ES. To connect an Extra ES. Same as above - for redundancy purpose For Synch and Clock Pulse. Same as above - for redundancy purpose Towards CN - For UP Redundancy - Towards CN - For UP Towards CN - For CP (SCCP) Redundancy - Towards CN - For CP MAIN PROCESSOR Redundancy - MAIN PROCESSOR Operation and Maintenance Redundancy - Operation and Maintenance RNC MODULE (IN POOL) RNC MODULE (IN POOL)

16 17 18 19 20 21 22 23 24 25 26 27 28

GPB GPB GPB SPB SPB SPB SPB SPB SPB ET/DUMMY ET/DUMMY ET/DUMMY SCB(r)

RNC MODULE (IN POOL) RANAP Redundancy - RANAP RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) IUB CONNECTIVITY IUB CONNECTIVITY IUB CONNECTIVITY Redundancy - Power IN , 4 ports to connect ES.

RNC 3820
SCB- DF TUB CMXB ET-IPG GPB GPB GPB GPB SPB SPB GPB ET-IPG SPB SPB ET-IPG

GPB SPB SPB ET-MF4 ET-MF4 ET-MF4 GPB SPB GPB ET-IPG CMXB TUB SCB- DF

RNC 3820

FUNCTIONALITY Power IN , 4 ports to connect ES. For Synch and Clock Pulse. connectivity for internal and external user-plane traffic ET- For IP connectivity MAIN PROCESSOR + Operation and Maintenance RNC MODULE (IN POOL) RANAP, RNSAP, SCCP RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) ET- For IP connectivity RNC MODULE (IN POOL) RNC MODULE (IN POOL) ET- For IP connectivity

RNC MODULE (IN POOL) RNC MODULE (IN POOL) RNC MODULE (IN POOL) ET - For ATM Connectivity ET - For ATM Connectivity ET - For ATM Connectivity Redundancy - RANAP, RNSAP, SCCP RNC MODULE (IN POOL) Redundancy - MAIN PROCESSOR + Operation and Maintenance ET- For IP connectivity redundancy - connectivity for internal & external UP traffic redundancy - For Synch and Clock Pulse. redundancy - Power IN , 4 ports to connect ES.

redundancy for inter-subrack Ethernet communication, each subrack is equipped with two CMXB boards.

o CMXB boards.

EXTENSION SUBRACK

RNC 3810

Total Numbers of GPB Total Numbers of SPB - works in pool

RNC 3820

3810 6 10

3820 4 9

RNC 3810

RNC 3820

Iu/Iur is to terminated to ET on MS

Iu/Iur can be terminated to ET on MS or ES

Board
SXB SCB ET-MFG ET-MC1, ET-MC41 ET-MX12, ET-MX13 ET-M1, ET-M3, ET-M4 SCB-DF GPB7 CMXB ET-IPG TUB SPB3 ET-MF4 ET-MF41

Other changes

TUB's have been moved to slots 2 and 27 in Main Subrack ESL carries user plane traffic between subracks CMXB & ET-IPG replaces ET-MFG. CMXB & ET-IPG connect through the Ethernet switchboard (ESL) on the ET-IPG in MS can be used for Iu-Cp & Iu-Up termination (refer to MO Stru ET-IPG in ES-1 & ES-2 can be used for Iu-Up termination, but not Iu-Cp (

Board
SXB SCB ET-MFG ET-MC1, ET-MC41 ET-MX12, ET-MX13 ET-M1, ET-M3, ET-M4 SCB-DF GPB7 CMXB ET-IPG TUB SPB3 ET-MF4 ET-MF41

Other changes

TUB's have been moved to slots 2 and 27 in Main Subrack ESL carries user plane traffic between subracks CMXB & ET-IPG replaces ET-MFG. CMXB & ET-IPG connect through the Ethernet switchboard (ESL) on the back plane. ET-IPG in MS can be used for Iu-Cp & Iu-Up termination (refer to MO Structure). ET-IPG in ES-1 & ES-2 can be used for Iu-Up termination, but not Iu-Cp (refer to MO Stru

Status
- Replaced - Replaced - Replaced - Replaced - Replaced - Replaced - New - New - New - New - Moved position - Same - Same - Same

e back plane. tructure). (refer to MO Structure).

SCB - DF
Switch core board - dual feed

Provides switch functionality (interface toward the switch core). Distributes system synchronization. Provides the ISL interfaces for connection between subracks. Provides power to the subrack, and in some cases to the fan unit. Controls the nearest CMXB, if present in the subrack. If an SCB-DF is faulty or is removed from the subrack, the nearest CMXB ceases to work within 90 seconds.

LED 1 3 4

PORT 0 PORT 2 PORT 3

CMXB
Common Main Switching Board The CMXB is a 20-port 10G BASE-CX4 Ethernet Switch that provides eight front-panel electrical Ethernet ports for user-plane data to and from the subrack, and 12 backplane Ethernet ports for device boards in a subrack.

provides 10G BASE-CX4 connectivity for internal and external user-plane traffic with redundancy between device boards in the same or different subracks.

The board is controlled (Ethernet and Reset) by the adjacent Switch Control Board - Dual Feed (SCB-DF) through a point-to-point 1G Ethernet SerDes Interface (MMEL)

RNC 3810

RNC 3810 moshell log

RNC 3820 moshell log

RNC 3820

In 3810 we have ethernetswitchpor

In 3820 we have ethernetswitchmo

In 3810 we have ethernetswitchport

In 3820 we have ethernetswitchmoduleport

RNC 3810
Cabinets Subracks Board Placement ISL ESL ATM backplane Ethernet Backplane Optimized for Supports
2 6 Fixed 310 Mbps NA 630 Mbps NA ATM IP

Subrack Capacity Switching

800W Low capacity ethernet

RNC 3820
1 3 Flexible 310 Mbps 10 Gbps 630 Mbps 10 Gbps IP ATM

1500W High capacity Internal

RNC 3810

bo command ("board overview")

RNC 3820

bo command ("board overview")

Advantages

Iu and Iur user plane can now be terminated in extension subracks ES-1 and ES-2. Inter-subrack user plane capacity increased with 10 Gb/s ESL (Ethernet Subrack Link) co New SCB-DF (Switch Core Board Dual Feed) power supply. RNC 3820 introduces 10 Gb Ethernet on external physical interface (Iu, Iur, Iub) via CMXB Supports interface types 10G BaseT and Optical (via SFP modules) New RNC Module Identity (rncModule) based on subrack and slot position. Introduces new black box configuration when adding an IP based RBS. The operator doe

1 and ES-2. t Subrack Link) connections. Iur, Iub) via CMXB and APP (Active Patch Panel).

The operator does not need to define a referred subrack.