You are on page 1of 2

Page 1

Date: 20/01/2014

Time: 15:36:58

Strengthening of Reinforced Concrete Structures with Sika CarboDur Composite Strengthening Systems
Disclaimer: The user is responsible for the results obtained from this programme.

FLEXURAL STRENGTHENING

Type of Cross Section T - beam Cross Section Geometry Width b = 0,2 m Effective width beff = 1 m Height h = 0,765 m Slab thickness hf = 0,12 m Concrete Mean strength fcm = 32,25 N/mm Characteristic strength fck = 24,05 N/mm Creep coefficient = 2,5 Composite Materials Elastic modulus Ef = 165 kN/mm Limiting strain f,lim = 0,006 Steel Reinforcement Elastic modulus Es = 205 kN/mm Characteristic yield stress fyk = 500 N/mm Top As2 = 0 mm at distance d2 = 0 m at distance d12 = 0 m Bottom As12 = 0 mm Bottom As11 = 625 mm at distance d11 = 0,035 m Bending Moments Bending moment during strengthening Mo = 146,68 kNm Required design moment after strengthening Msd = 298,6 kNm Acting moment under rare load combination Mser,r = 187,7 kNm Acting moment under quasi-permanent load combination Mser,q-p = 187,7 kNm

Results
Ultimate Limit State Resisting design moment before strengthening Mrd,o = 195,61 kNm

Page 2

Required FRP cross section Af = 147,88 mm Applied FRP cross section Af = 420,00 mm Resisting design moment after strengthening Mrd = 491,12 kNm Degree of strengthening Mrd / Mrd,o = 2,511 Serviceability Limit State - Rare Load Moment capacity before strengthening Mser,r,o = 175,36 kNm Required FRP cross section Af = 301,13 mm Applied FRP cross section Af = 420,00 mm Moment capacity Mser,r = 192,27 kNm Steel stress fs11 = 400,00 0,8 x fyk = 400,00 N/mm Concrete stress c = 6,04 0,6 x fck = 14,43 N/mm Serviceability Limit State - Quasi-permanent Load Moment capacity before strengthening Mser,q-p,o = 170,53 kNm Required FRP cross section Af = 417,60 mm Applied FRP cross section Af = 420,00 mm Moment capacity Mser,q-p = 187,68 kNm Steel stress fs11 = 400,00 0,8 x fyk = 400,00 N/mm Concrete stress c = 3,58 0,45 x fck = 10,82 N/mm Final Design is controlled by Serviceability Limit State - Quasi-permanent Load Final required FRP cross section Af = 417,60 mm Applied FRP Width 50 mm Thickness 1,2 mm Number of strips 7 Applied FRP cross section

Af = 420,00 mm

You might also like