You are on page 1of 1

AB1 HEAVY METAL ANCHOR CE 1

for cracked and non-cracked concrete


code

do [mm] Lt [mm] f [mm] h1 [mm] hef [mm] tfix [mm]

FE210405
FE210410
FE210415
FE210475
FE210476
FE210440
FE210480
FE210445
FE210490

8
8
8
10
10
12
12
12
12

72
92
112
112
132
103
118
148
178

32
52
72
67
87
53
68
98
115

60
60
60
75
75
90
90
90
90

45
45
45
60
60
70
70
70
70

10
30
50
30
50
5
20
50
80

pieces/box

13
13
13
17
17
19
19
19
19

Tinst
[Nm]
20
20
20
35
35
50
50
50
50

Ch

Tinst

pieces/box

13
13
17
17
19
19
24

20
20
35
35
70
70
120

50
50
50
25
20
20
10

Ch

100
50
50
25
25
25
25
25
25

Galvanised carbon steel

code
AI8095A4
AI80112A4
AI1095A4
AI10132A4
AI12110A4
AI12163A4
AI16123A4

do [mm] Lt [mm] f [mm] h1 [mm] hef [mm] tfix [mm]


A4
A4
A4
A4
A4
A4
A4

8
8
10
10
12
12
16

92
112
92
132
118
163
123

52
72
47
87
68
113
65

60
60
75
75
90
90
110

45
45
60
60
70
70
70

30
50
10
50
20
65
5

AISI316/A4 stainless steel


certified CE Option 1 anchor for application on cracked and non-crack concrete
certificate of fire resistance F120
suited for applications on compact materials: stone, concrete
designed for through fastening
long expansion spacer in three sectors

Characteristic values of tensile strength (NRk) for application on C20/25 concrete

NRk,p [KN]
safety factor Mp
increase factor for
NRk,p for concrete

Cracked concrete C20/25


Non-cracked concrete C20/25
C30/37
C 35/45
C 40/50
C 45/55
C 50/60

M8

M10

M12

M16

5.0
9.0
1.80

9.0
16.0
1.80
1.10
1.16
1.20
1.24
1.28

12.0
20.0
1.80

20.0
35.0
1.50

Characteristic values of shear strength (VRk) for applications on C20/25 concrete

VRk,s [KN]
safety factor Ms

steel
Stainless steel

M8

M10

M12

M16

10.0
11.0
1.50

18.0
17.0
1.50

23.0
25.0
1.50

44.0
47.0
1.50

M8

M10

M12

M16

68
135
100
50
50

90
180
120
55
50

105
210
140
60
55

128
255
170
70
85

geometric installation characteristics

Critical distance from edge


Critical centre distance
Concrete support minimum thickness
Minimum centre distance
Minimum distance from edge

ccr,N [mm]
scr,N [mm]
hmin [mm]
smin [mm]
cmin [mm]

The strength values are calculated according to Design Method A (ETAG001).


The values indicated refer to anchors installed respecting the distances indicated in the table. For small distances apply
the ETA reduction coefficients

144