You are on page 1of 10

Configure ISU

Master Data Template


to create test data fast and easy
by Daniel Toba 2009

Table of Contents
Step 1: Go to transaction ECUSTPROD ................................... 3 Step 2: Activate Business Partner node .................................. 4 Step 3 Activate Business Partner Address Node......................... 6 Step 4 Activate Contract Account Node.................................. 8 Step 5 Activate Device Info Record ....................................... 9 Step 6 Activate Connection Object Node ...............................11 Step 7: Activate Premise Node ...........................................13 Step 8: Activate Point of Delivery Node ................................14 Step 9: Activate Utility Installation Node...............................15 Step 10: Activate Install Device Node ...................................17 Step 11: Activate Contract Node.........................................19 Step 12: Activate Move-In Node ..........................................20 Step 13: Save master Data and Test.....................................21

www.sap-isu.net

2/21

Configure Master Data Template

Step 1: Go to transaction ECUSTPROD

Fill in the following fields: MD Template: Z_ISU_TEST_DATA Select MD Template Category : NEWCUSTPOD Press (new) button.

www.sap-isu.net

3/21

Configure Master Data Template

Step 2: Activate Business Partner node


Select Node and press .

Set up the following attributes as follows: Attribute Name BU_GROUP TYPE NAME_FIRST NAME_LAST XSEXF XSEXM XSEXU Services I Identifying Constant I Identifying Constant P Parameter P Parameter I Identifying Constant I Identifying Constant I Identifying Constant Values 0001 1 NAME_FIRST NAME_LAST Notes Your configuration settings might be different Your configuration settings might be different NAME_FIRST NAME_LAST

www.sap-isu.net

4/21

Configure Master Data Template

www.sap-isu.net

5/21

Configure Master Data Template

Step 3 Activate Business Partner Address Node


Select Business Partner Address Node and press Activate Nodes button.

Set up the following attributes as follows: Attribute Name STREET HOUSE_NUM1 POST_CODE1 NAME_LAST CITY1 COUNTRY Services P Parameter P Parameter P Parameter P Parameter P Parameter P Parameter Values STREET HOUSE_NUM1 POST_CODE1 NAME_LAST CITY1 COUNTRY Notes

www.sap-isu.net

6/21

Configure Master Data Template

www.sap-isu.net

7/21

Configure Master Data Template

Step 4 Activate Contract Account Node


Select contract account and press activate node. Set up the following attributes as follows: Attribute Name VKTYP VKBEZ TOGRUP VERTYP ZAHLKOND KTOKL KOFIZ_SD FORMKEY OPBUK STDBK STDBK Services I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant I Identifying Constant Values 01 Contract Account 0001 UTIL 0001 0001 01 ZIS_U_BILL 1000 1000 1000 Notes Your configuration settings might be different

Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different Your configuration settings might be different

www.sap-isu.net

8/21

Configure Master Data Template

Step 5 Activate Device Info Record


Note You must define a device info record in your system. To do this do the following: - go to transaction MM01 and create your material (for example: DEVINFOREC) fill in just the basic data 1 and basic data 2 views - go to EG01 to create your device category use the same name as the one created above

Click on Device Info Record and press Activate Nodes.

Set up the following attributes as follows: Attribute Name SERNR MATNR EQUNR DIVISION KEYDATE Services P Parameter I Identifying Constant P Parameter I Identifying Constant P Parameter Values SERNR DEVINFOREC EQUNR 01 KEYDATE Notes Your configuration settings might be different

www.sap-isu.net

9/21

Configure Master Data Template

Note: Your Device Category has a default register group. This master data template is configured o work with one register. Therefore you must configure your device category with a register group that has one register. However, you can use more register groups by adding additional nodes. To add additional nodes just select the first node and press Duplicate Node. The system will create a new node for Register and there you will have your 2 registers. Select Create Register for Device and press Activate Nodes.

Set up the following attributes as follows: Attribute Name ZWNUMMER Services I Identifying Constant Values 001 Notes Your configuration settings might be different

www.sap-isu.net

10/21

Configure Master Data Template

You might also like