Step 2 Perform pressure test on the second side as per above stated procedure.
Dokumentnamn/Dokument name
GEN-C 0026
Utgva/Issue
Conny Johansson
Publiserad/Published
Bjrn Hillefors
Godknt datum/Approval date
9
Sida/Page
2007-02-06
2007-02-06
2 (2)
Step 3 Drain the unit after successful pressure test. Sign the final inspection report that the unit is successfully pressure tested.
3. Time schedule for pressure tests A. PED 97/23/EC with CE-mark. PHE shall be pressure tested 30 minutes on each side. B. PED 97/23/EC acc. to SEP. PHE shall be pressure tested 15 minutes on each side. C. ASME VIII, Div 1. PHE shall be pressure tested 30 minutes on each side. D. Double wall (GD) exchangers 30 minutes on first side 30 minutes on second side 240 minutes (4 hours) double sided 4. Pressure gauge range Pressure tests between 0-20 bar 10-35 bar 30-55 bar Use gauge 0-25 bar 0-40 bar 0-60 bar