Professional Documents
Culture Documents
Air Cond Tech
Air Cond Tech
.10 m/s
Equal friction method
-
.
AB
Qt = Q1 + Q2 + Q2
Qt = 4 + 3 + 1 = 8 m 3 / s
10 m/s .
) (- .
m/s
7.5
6.5
10
7.5
6.5
5.5
10
7.5
10
7.5
. 8 m/s
V = 8 m/s
d 2V
48
= 1.128 m
8
= Qt
=d
fL V 2
d 2
P =
0.00015
= 0.000133
1.128
.
) (- .
kg/m3
Pa.s
-10
1.341
16.768 x 10-6
1.292
17.238 x 10-6
10
1.247
-6
20
1.204
18.178 x 10-6
30
1.164
18.648 x 10-6
40
1.127
19.118 x 10-6
50
1.092
19.588 x 10-6
17.708 x 10
) (- .
, mm
0.9 -9.0
0.3 3.0
0.18 0.9
0.26
0.12
0.15
0.045
0.015
0.0
Vd 1.184 8 1.128
=
= 5.80 10 5
6
18.413 10
= Re
Moody Re /d f
.
f = 0.0145
fL V 2
0.0145 30 8 2
= 1.184
= 14.61 Pa
d 2
1.128
2
P 14.61
=
= 0.487 Pa / m
L
30
P =
Pa/m
.
BE
f V d
.
d 2V
V2
8Q 2
= 2 4
2
d
= Q = AV
4Q
16Q 2
2
,
V
=
d 2
2d 4
= V
P
f V2
f 8Q 2
8Q 2
=
=
=
f
L
d 2
d 2d 4
2d 5
8 fQ 2
8 1.184 0.0145 1
=d
=5
= 0.491 m
2
P / L
2 0.487
5
4Q
= 5.281 m / s
d 2
= V
d V Re Moody f
.
V d:
Vd 1.184 5.281 0.491
=
= 1.66 105
6
18.413 10
= Re
0.00015
= 0.000305
0.491
f = 0.016
d = 0.501 m
V = 5.073 m / s
V d:
Vd 1.184 5.073 0.501
=
= 1.63 105
6
18.413 10
= Re
0.00015
= 0.000299
d
0.501
f = 0.016
=
V d .
d = 0.501 m
V = 5.073 m / s
= d 2V
= Qcal = AV
Q = 1 m3/s
BC
f V d
.
8 fQ 2
8 1.184 0.016 7 2
5
=
= 1.091 m
2 P / L
2 0.487
4Q
47
= V
=
= 7.489 m / s
2
d
1.0912
d =5
d V Re Moody f
.
V d:
Vd 1.184 7.489 1.091
=
= 5.25 10 5
18.413 10 6
= Re
0.00015
= 0.000137
1.091
f = 0.0146
d = 1.071 m
V = 7.768 m / s
V d:
Vd 1.184 7.768 1.071
=
= 5.35 10 5
6
18.413 10
= Re
0.00015
= 0.00014
d
1.071
f = 0.0146
=
V d .
d = 1.071 m
V = 7.768 m / s
= d 2V
= Qcal = AV
Q = 7 m3/s
CF
f V d
.
8 fQ 2
8 1.184 0.0146 3 2
5
=
= 0.7632 m
2 P / L
2 0.487
4Q
43
= V
=
= 6.557 m / s
2
d
0.76212
d =5
d V Re Moody f
.
V d:
Vd 1.184 6.557 0.7632
=
= 3.22 10 5
18.413 10 6
= Re
0.00015
= 0.000197
d
0.7632
f = 0.0163
=
d = 0.780 m
V = 6.275 m / s
V d:
Vd 1.184 6.275 0.780
=
= 3.15 10 5
18.413 10 6
= Re
0.00015
= 0.000192
d
0.780
f = 0.0164
=
.
d = 0.780 m
V = 6.275 m / s
= d 2V
= Qcal = AV
Q = 3 m3/s
CD
f V d
.
8 fQ 2
8 1.184 0.0164 4 2
5
=
= 0.8764 m
2 P / L
2 0.487
4Q
4 4
= V = 2
= 6.630 m / s
d
0.85512
d =5
d V Re Moody f
.
V d:
Vd 1.184 6.630 0.8764
= 3.74 10 5
=
18.413 10 6
= Re
0.00015
= 0.000171
d
0.8764
f = 0.0157
=
d = 0.869 m
V = 6.747 m / s
V d:
Vd 1.184 6.747 0.869
=
= 3.77 10 5
18.413 10 6
= Re
0.00015
= 0.000173
d
0.869
f = 0.0159
=
d = 0.869 m
V = 6.747 m / s
V, d .
.
= d 2V
= Qcal = AV
Q = 4 m3/s
.
)P/L = 0.487 (Pa/m
Qcal
)d (m
V (m/s
)Q (m3/s
)L (m
0.0145
8.000
1.128
8.00
30
A-B
0.0146
6.998
1.071
7.77
15
B-C
0.0159
4.002
0.869
6.75
75
C-D
0.016
1.000
0.501
5.07
30
B-E
0.0164
2.998
0.780
6.275
15
C-F
Section
20 oC
.
AB
.
Qt = Q1 + Q2 + Q2
Qt = 4 + 3 + 1 = 8 m 3 / s
V = 8 m/s
.
V = 8 m/s
d 2V
= Qt
48
= 1.128 m
8
=d
fL V 2
d 2
P =
0.00015
= 0.000133
1.128
. 20 oC
Vd 1.184 8 1.128
=
= 5.80 10 5
18.413 10 6
= Re
Moody Re /d f
.
f = 0.0145
fL V 2
0.0145 30 8 2
= 1.184
= 14.61 Pa
d 2
1.128
2
P 14.61
=
= 0.487 Pa / m 0.5
Pa / m
L
30
P =
P=0.5 Pa/m
:
)P/L = 0.5 (Pa/m
Qcal
)d (m
V (m/s
)Q (m3/s
)L (m
8.094
1.135
8.00
30
A-B
7.145
1.080
7.80
15
B-C
4.149
0.875
6.90
75
C-D
0.999
0.515
4.80
30
B-E
3.010
0.780
6.30
15
C-F
Section
V = 8 m/s
.
d = 1.135 m
P = 0. 5
Pa / m
V = 7m / s
BC:
V = 7m / s
V = 6m / s
V = 6m / s
BE:
C D:
CF:
.
)P (Pa/m
Qcal
)d (m
V (m/s
)Q (m3/s
)L (m
0.50
8.094
1.135
8.00
30
A-B
0.38
7.020
1.130
7.00
15
B-C
0.38
4.032
0.925
6.00
75
C-D
1.35
1.017
0.430
4.00
30
B-E
0.45
3.016
0.800
6.00
15
C-F
Section
BE
4 m/s
.
BE
)P (Pa/m
Qcal
)d (m
V (m/s
)Q (m3/s
)L (m
0.50
8.094
1.135
8.00
30
A-B
0.38
7.020
1.130
7.00
15
B-C
0.38
4.032
0.925
6.00
75
C-D
0.30
1.039
0.575
4.00
30
B-E
0.45
3.016
0.800
6.00
15
C-F
Section
(ab )0.625
(a + b )0.25
d = 1. 3
Air Fan
:
V2
+ gZ = C
2
V 2
+ gZ = C
2
PS + PV + PZ = PT
P+
If dZ = 0,
PS + PV = PT ,
Where, PS : Static Pressure, PV : Velocity Pressure or Dynamic Pressure
PT : Total Pressure.
PV = PT PS , where PT , PS are measuring by Pitotube.
2 PV
= or V
V 2
2
= PV
PS1 + PV 1 = PS 2 + PV 2 = PT
PS 1 + PV 1 = PS 2 + PV 2 + PL
where, PL : total pressure drop or hydraulic losses between 1 and 2.
PS1 + PV 1 + FTP = PS 2 + PV 2 + PL
where, FTP is the pressure rise due to the fan work and is called
the Fan Total Pressure.
V12 FTP PS 2 V22 PL
+
=
+
+
2
2
2
PS1
:
fL V 2
, where, d : hydraulic mean diameter
d 2
PF =
:
, where, K : constant
V 2
2
PM = K
:
P
V2
P
Power = m& F + M + e
LV2
V 2 Ve2
= m& f
+K
+
d 2
2
2
= Poweract
) (- .
Component
)P (Pa or N/m2
Damper
50
Filter
100
Cooling coil
150
Eliminators
50
Heating coil
150
Air washer
100
50
Component
Inlet
0.40
0.30
0.03
0.40
Standard 90 elbow
0.75
Expander
0.75
Reducer
0.05
Damper
0.20
Exit grille
0.50
Fan Power
:
P
LV2
V 2 Ve2
Power = W = m&
+ f
+ K
+
d 2
2
2
Air Handling
Exit
V 2
+ e
Fitting 2
P
V2
1 P
= m&
L
+
+ K
Air Handling
L
Friction
2
-
.
.
P
LV2
V 2 Ve2
Power = W = m&
+ f
+ K
+
d 2
2
2
Air Handling
P
V2
1 P
= m&
+
L
+ K
Air Handling
L
Friction
2
V 2
+ e
Fitting 2 Exit
P
V2
1 P
= V&
+
L
+ K
Air Handling
L
Friction
2
V 2
+ e
Fitting 2 Exit
1.184
Air Handling
Power = 1.184 8
30 0.487
82
+
+ 0.3
2 A B
1.184
15 0.487
7.77 2
+ 1.184 7
+ 0.05
2
1.184
B C
75 0.487
6.75 2
+ 1.184 4
+ (0.05 + 0.75 + 0.5 + 1)
2
1.184
30 0.487
5.07 2
+ 1.184 1
+ (0.75 + 0.5 + 1)
2
1.184
C D
BE
15 0.487
6.28 2
+ 1.184 3
+ (0.75 + 0.5 + 1)
2 C F
1.184
Power = 4607.811 + 63.644 + 394.252 + 48.849 + 179.511 = 5294.07 W
Power = 5.3 kW
-
.
-
15 m3/min .
-
2 m3/s .
Moody Chart