You are on page 1of 1

E R R O R

M E M O R Y
R E P O R T
------------------------------------Date:
04/04/14 15:36:03
ECU:
DDE40KW0
JobStatus: OKAY
Variant:
DDE40KW0
------------------------------------------------------------RESULT:
1 errors in error memory !
------------------------------------------------------------4501

Rail-pressure regulating valve

Error frequency : 2
Logistic counter: 40
Error occured 1. times at:
Engine speed
fuel pre-supply pressure
Supply voltage
RPC rail pressure
Fehler aufgetreten bei

749.25
3.90
13.89
132.53
273920.00

1/min
bar
V
bar
km

749.25
3.94
14.00
132.53
273940.00

1/min
bar
V
bar
km

Error occured 2. times at:


Engine speed
fuel pre-supply pressure
Supply voltage
RPC rail pressure
Fehler aufgetreten bei
Error present
Sporadic error
power stage failure
Errorcode: 11 95 28 02 FC 80 1E F4 78 16 6B 00 80 1E F6 79
16 6B 02 00 00 00 00 00 00
=============================================================