You are on page 1of 1

DISEO Y CALCULO DE RECIPIENTES SUJETOS A Presin.

A.S.M.E.
H
Datos:
m
ft(pies)
in(pulg)
m
ft
Diametro
D=
23.00
75.46
905.51
0.00
0.00
Altura
h=
9.50
31.17
374.02
Altura Efec.
H=
9.00
29.53
354.33
Radio
R=
11.50
37.73
452.76
1.50
4.92
Material
A-36
S=
36000.00
lb/pulg2
presion de agua por una columna de 1 pie de altura= 0.4331 lb/pulg2
E (factor de Eficacia en soldadura) (0.80-0.85)
E= 0.8
3.00
9.84
P=P0+PH+30 (lb/pulg2) o
P=(P0+PH)1.1 (lb/pulg2)

=
P0=
presion servicio=
0 lb/pul2
0.6
Phi= Pe*H
P
4.50
14.76
t(pulg)
t(mm)
H1= 0.00
0.000
30.000
0.47
12.0
H2= 4.92
2.558
32.558
0.51
13.0
6.00
19.69
H3= 9.84
5.115
35.115
0.55
14.0
H4= 14.76
7.673
37.673
0.59
15.1
7.50
24.61
H5= 19.69
10.231
40.231
0.63
16.1
H6= 24.61
12.788
42.788
0.67
17.1
H7= 29.53
15.346
45.346
0.71
18.1
9.00
29.53

diseo de tapa de fondo=


f=D/h <2-3>
=
0.2
E=(0.9-1.0)= 1
0.456 pulg
tf=
11.59 mm.
12.0 mm.
Usamos
diseo de tapa de cupula (min)=
=

tc=

0.2

0.321 pulg
8.156 mm.

Usamos

12.0 mm.

P=

12.0 mm.

8400 (SOFTWARE)
lb/pulg2