Professional Documents
Culture Documents
WAG54GS-En V11 English User Guide
WAG54GS-En V11 English User Guide
WARNING: This exclamation point indicates that there is a caution or warning and it is something that could damage your property or product.
WEB: This globe icon indicates a noteworthy website address or e-mail address.
Online Resources
Website addresses in this document are listed without http:// in front of the address because most current web browsers do not require it. If you use an older web browser, you may have to add http:// in front of the web address. Resource Linksys Linksys International Glossary Network Security Website www.linksys.com www.linksys.com/international www.linksys.com/glossary www.linksys.com/security
Table of Contents
Chapter 1: Product Overview 4
Chapter 3: Installation
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Setup > Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Setup > DDNS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Setup > Advanced Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Wireless > Basic Wireless Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wireless > Wireless Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wireless > Wireless Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Wireless > Advanced Wireless Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Security > Firewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Security > VPN Passthrough . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Access Restrictions > Internet Access Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Applications and Gaming > Single Port Forwarding . . . . . . . . . . . . . . . . . . . . . . . 18 Applications and Gaming > Port Range Forwarding . . . . . . . . . . . . . . . . . . . . . . . 18 Applications & Gaming > Port Range Triggering . . . . . . . . . . . . . . . . . . . . . . . . . .19 Applications and Gaming > DMZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Applications and Gaming > QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Administration > Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Administration > Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Administration > Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Administration > Backup & Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Administration > Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Administration > Firmware Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Status > Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Status > Local Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Status > Wireless . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Status > DSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
27 28 29
ii
Table of Contents
Appendix D: Regulatory Information 30
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Safety Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Industry Canada Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Avis dIndustrie Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Declaration of Conformity with Regard to EU Directive 1999/5/EC (R&TTE Directive) . . 31 CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 National Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Product Usage Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Technical Documents on www.linksys.com/international . . . . . . . . . . . . . . . . . . . . 33 User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
iii
Chapter 1
Product Overview
Power (Green) The Power LED lights up and stays on while the Gateway is powered on. Wireless (Green) The Wireless LED lights up when the wireless feature is enabled. It flashes when the Gateway is actively sending or receiving data over the network. Ethernet 1-4 (Green) These numbered LEDs, corresponding with the numbered ports on the Gateways back panel, serve two purposes. If the LED is continuously lit, the Gateway is successfully connected to a device through that port. It flashes to indicate network activity over that port. DSL (Green) The DSL LED lights up whenever there is a successful DSL connection. The LED flashes while the Gateway is establishing the ADSL connection. Internet (Green) The Internet LED lights up and stays on when there is a connection made through the Internet port. It flashes to indicate network activity over the Internet port.
Front Panel
Power Button When you want to power the Gateway on or off, push this button. SecureEasySetup Button (Orange/White) It lights up when the Gateway is powered on. The SecureEasySetup button lights up white to indicate that the wireless network uses WPAPersonal with TKIP security. Otherwise, the button lights up orange. NOTE: SecureEasySetup is a feature that makes it easy to set up your wireless network. If you have devices that support SecureEasySetup, run the Gateways Setup Wizard CD-ROM, and follow the on-screen instructions to use SecureEasySetup. To use the SecureEasySetup feature, press the SecureEasySetup button for one second and release. Ten seconds later, this button changes to white and starts flashing to indicate that the Gateway is in SecureEasySetup mode. After the Gateway has generated the wireless network name (SSID) and WPA-Personal key, the button stops flashing and stays white. To clear the wireless network name and WPAPersonal key, press and hold down the button for five seconds. The button flashes slowly as the Gateway resets itself. When the reset is complete, the button changes to orange.
Back Panel
Line The Line port connects to the ADSL line. Ethernet 1, 2, 3, 4 These Ethernet ports (1, 2, 3, 4) connect the Gateway to wired computers and other Ethernet network devices. Reset There are two ways to reset the Gateways factory defaults. Either press and hold the Reset button for approximately five seconds, or restore the defaults from the Administration > Factory Defaults screen of the Gateways web-based utility. Power The Power port is where you will connect the power adapter.
Chapter 2
4. Enable encryption
Encryption protects data transmitted over a wireless network. Wi-Fi Protected Access (WPA/WPA2) and Wired Equivalency Privacy (WEP) offer different levels of security for wireless communication. A network encrypted with WPA/WPA2 is more secure than a network encrypted with WEP, because WPA/WPA2 uses dynamic key encryption. To protect the information as it passes over the airwaves, you should enable the highest level of encryption supported by your network equipment. WEP is an older encryption standard and may be the only option available on some older devices that do not support WPA.
Password protect all computers on the network and individually password protect sensitive files. Change passwords on a regular basis. Install anti-virus software and personal firewall software. Disable file sharing (peer-to-peer). Some applications may open file sharing without your consent and/or knowledge.
Keep wireless routers, access points, or gateways away from exterior walls and windows. Turn wireless routers, access points, or gateways off when they are not being used (at night, during vacations). Use strong passphrases that are at least eight characters in length. Combine letters and numbers to avoid using standard words that can be found in the dictionary.
Chapter 3
Installation
NOTE: To avoid interference, you may need to place a microfilter or splitter between the phone cable and wall jack. Contact your ISP to determine if one is required. (UK residents need to connect the microfilter to the wall phone jack with ADSL service and then connect one end of the provided phone cable to the RJ-11 port on it.) If you use ISDN, then you do not need a microfilter. 6. Connect the power adapter to the Gateways power port and the electrical outlet.
Chapter 3: Installation
Linksys strongly recommends that you run the Setup CDROM. If you have problems running the Setup CD-ROM, use this chapter.
Connection
1. Make sure that all the devices that you are working with are powered down, including your computer(s) and the Gateway. If you have a modem connected to your network, disconnect it. The Gateway replaces your modem. 2. Connect one end of the provided Ethernet cable to your computers Ethernet adapter. Connect the other end of the Ethernet cable to one of the Ethernet ports on the back of the Gateway.
7. To power on the Gateway, push the power button on the front panel.
Connect the Computer
8. Power on the computer that you want to use to configure the Gateway. NOTE: If you have more than one phone and you experience static on the line after installing the Gateway, then you need to install an additional microfilter for each phone or fax that you use. Connection is complete. Continue to the Setup section.
3. Repeat step 2 for every computer or device that you want to connect to the Gateway via Ethernet. If you connect more than four computers to the Gateway, you also need to connect a switch to the Gateway. NOTE: If your computers Ethernet adapter is not set up, refer to the Ethernet adapters documentation for more information. 4. Connect one end of the provided phone cable to the wall jack with ADSL service. 5. Connect the other end of the phone cable to the Line port on the back of the Gateway.
Setup
For setup, configure the Gateway to access the Internet through your ADSL Internet Service Provider (ISP). Use the setup information provided by your ISP. Continue to Chapter 4: Advanced Configuration, and complete the following sections:
Setup > Basic Setup Wireless > Basic Wireless Settings Wireless > Wireless Security
After completing the setup, to test it, enter www.linksys.com/registration in the web browsers Address field, and press Enter.
Connect the DSL
Setup is complete.
Chapter 4
Advanced Configuration
Internet Setup
The Internet Setup section configures the Gateway to your Internet connection. Most of this information can be obtained through your ISP.
Login Screen
RFC 2364 PPPoA RFC 2516 PPPoE RFC 1483 Routed IPoA RFC 1483 Bridged Bridge Mode Only
VC Settings
Configure your Virtual Circuit (VC) settings in this section. Multiplexing Select LLC or VC, depending on your ISP.
Wireless-G ADSL Gateway with SpeedBooster 7
Chapter 4
Advanced Configuration
inactivity, Connect on Demand enables the Gateway to automatically re-establish your connection as soon as you attempt to access the Internet again. To use this option, select Connect on Demand. In the Max Idle Time field, enter the number of minutes you want to have elapsed before your Internet connection terminates. The default Max Idle Time is 5 minutes. Keep Alive: Redial Period If you select this option, the Gateway will periodically check your Internet connection. If you are disconnected, then the Gateway will automatically re-establish your connection. To use this option, select Keep Alive. In the Redial Period field, you specify how often you want the Gateway to check the Internet connection. The default Redial Period is 30 seconds.
QoS Type Select from the drop-down menu: CBR (Continuous Bit Rate) to specify fixed bandwidth for voice or data traffic; UBR (Unspecific Bit Rate) for application that are not time-sensitive, such as e-mail; or VBR (Variable Bit Rate) for bursty traffic and bandwidth-sharing with other applications. PCR Rate For the Peak Cell Rate (PCR), divide the DSL line rate by 424 to get the maximum rate the sender can send cells. Enter the rate in the field (if required by your service provider). SCR Rate The Sustain Cell Rate (SCR) sets the average cell rate that can be transmitted. The SCR value is normally less than the PCR value. Enter the rate in the field (if required by your service provider). Autodetect Select Enable to have the settings automatically entered, or select Disable to enter the values manually. Virtual Circuit These fields consist of two items: VPI (Virtual Path Identifier) and VCI (Virtual Channel Identifier). Enter the settings provided by your ISP. DSL Modulation Select the appropriate mode: MultiMode, T1.413, G.dmt, G.lite, ADSL2, or ADSL2+. Contact your ISP if you are not sure which mode to use. Follow the instructions for your type of encapsulation.
PPPoE Settings
Username and Password Enter the Username and Password provided by your ISP. Connect on Demand: Max Idle Time You can configure the Gateway to cut the Internet connection after it has been inactive for a specified period of time (Max Idle Time). If your Internet connection has been terminated due to inactivity, Connect on Demand enables the Gateway to automatically re-establish your connection as soon as you attempt to access the Internet again. To use this option, select Connect on Demand. In the Max Idle Time field, enter the number of minutes you want to have elapsed before your Internet connection terminates. The default Max Idle Time is 5 minutes. Keep Alive: Redial Period If you select this option, the Gateway will periodically check your Internet connection. If you are disconnected, then the Gateway
PPPoA Settings
Username and Password Enter the Username and Password provided by your ISP. Connect on Demand: Max Idle Time You can configure the Gateway to cut the Internet connection after it has been inactive for a specified period of time (Max Idle Time). If your Internet connection has been terminated due to
Wireless-G ADSL Gateway with SpeedBooster
Chapter 4
Advanced Configuration
IP Settings
Your ISP provides these settings. Internet IP Address Enter the Gateways IP address, as seen from the Internet. Subnet Mask Enter the Gateways Subnet Mask, as seen from the Internet (including your ISP). Default Gateway Enter the IP address of the ISP server. Primary (Required) and Secondary (Optional) DNS Enter the DNS (Domain Name System) server IP address(es) provided by your ISP. At least one is required.
will automatically re-establish your connection. To use this option, select Keep Alive. In the Redial Period field, you specify how often you want the Gateway to check the Internet connection. The default Redial Period is 30 seconds.
IP Settings
Your ISP provides these settings. Internet IP Address Enter the Gateways IP address, as seen from the Internet. Subnet Mask Enter the Gateways Subnet Mask, as seen from the Internet (including your ISP). Default Gateway Enter the IP address of the ISP server. Primary (Required) and Secondary (Optional) DNS Enter the DNS (Domain Name System) server IP address(es) provided by your ISP. At least one is required.
IP Settings
Select Obtain an IP Address Automatically if your ISP says you are connecting through a dynamic IP address. If you are required to use a permanent (static) IP address to connect to the Internet, then select Use the following IP Address. Your ISP provides the settings needed for the following fields: Internet IP Address Enter the Gateways IP address, as seen from the Internet. Subnet Mask Enter the Gateways Subnet Mask, as seen from the Internet (including your ISP). Default Gateway Enter the IP address of the ISP server. Primary (Required) and Secondary (Optional) DNS Enter the DNS (Domain Name System) server IP address(es) provided by your ISP. At least one is required.
IPoA
If you are required to use IPoA (IP over ATM), then select IPoA.
If you are using your Gateway as a bridge, which makes the Gateway act like a stand-alone modem, select Bridge
Chapter 4
Advanced Configuration
Local IP Address The default value is 192.168.1.1. Subnet Mask The default value is 255.255.255.0.
Mode Only. All NAT and routing settings are disabled in this mode.
Optional Settings
Some of these settings may be required by your ISP. Verify with your ISP before making any changes.
Host Name and Domain Name These fields allow you to supply a host and domain name for the Gateway. Some ISPs, usually cable ISPs, require these names as identification. You may have to check with your ISP to see if your broadband Internet service has been configured with a host and domain name. In most cases, leaving these fields blank will work. MTU MTU is the Maximum Transmission Unit. It specifies the largest packet size permitted for Internet transmission. Select Manual if you want to manually enter the largest packet size that is transmitted. To have the Gateway select the best MTU for your Internet connection, keep the default, Auto. Size When Manual is selected in the MTU field, this option is enabled. Leave this value in the 1200 to 1500 range. The default, MTU is configured automatically.
DHCP Server A Dynamic Host Configuration Protocol (DHCP) server automatically assigns an IP address to each computer on your network for you. Unless you already have one, Linksys recommends that you keep the default, Enable. You can also use the Gateway in DHCP Relay mode. (This setting is not available for all encapsulation types.) DHCP Server If you enable the DHCP Relay mode for the DHCP Server setting, enter the IP address for the DHCP relay server in the fields provided. (This setting is not available for all encapsulation types.) Starting IP Address Enter a value for the DHCP server to start with when issuing IP addresses. Because the Gateways default IP address is 192.168.1.1, the Starting IP Address must be 192.168.1.2 or greater, but smaller than 192.168.1.253. The default is 192.168.1.100. Maximum Number of DHCP Users Enter the maximum number of users (network devices) that can obtain an IP address. The number will vary depending on the starting IP address entered and cannot be greater than 253. The default is 50. Client Lease Time The Client Lease Time is the amount of time a network device will be allowed connection to the Gateway with its current dynamic IP address. Enter the number of minutes that the device will be leased this dynamic IP address. After the time is up, the device will be automatically assigned a new dynamic IP address. The default is 0 minutes, which means one day. Static DNS 1-3 The Domain Name System (DNS) is how the Internet translates domain or website names into Internet addresses or URLs. At least one DNS server IP address is provided by your ISP. You can enter up to three
10
Network Setup
The Network Setup section changes the settings on the network connected to the Gateways Ethernet ports. Wireless setup is performed through the Wireless tab.
Gateway IP
The values for the Gateways Local IP Address and Subnet Mask are shown here. In most cases, keeping the default values will work.
Chapter 4
Advanced Configuration
DynDNS.org
DNS server IP addresses here. The Gateway will use these for quicker access to functioning DNS servers. WINS The Windows Internet Naming Service (WINS) converts NetBIOS names to IP addresses. If you use a WINS server, enter that servers IP address here. Otherwise, leave this field blank.
Time Settings
Time Zone Select the time zone in which your network functions. Automatically adjust clock for daylight saving changes Select this option if you want the Gateway to automatically adjust for daylight saving time.
Username Enter the Username for your account. Password Enter the Password for your account.
Time Settings and Language
Host Name Enter the DDNS URL assigned by the service. Status The status of the DDNS service connection is displayed. Connect To manually trigger an update, click this button. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Language
Select the language you want the web-based utility to use: English, French, or German. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
TZO.com
DDNS
DDNS Service
If your DDNS service is provided by DynDNS.org, then select DynDNS.org from the drop-down menu. If your DDNS service is provided by TZO, then select TZO.com. The features available on the DDNS screen will vary, depending on which DDNS service provider you use.
E-mail Address Enter the E-mail Address for your account. TZO Password Enter the Password for your account. Domain Name Enter the DDNS URL assigned by the service. Status The status of the DDNS service connection is displayed here. Connect To manually trigger an update, click this button. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
11
Chapter 4
Advanced Configuration
Destination IP Address The Destination IP Address is the IP address of the remote network or host to which you want to assign a static route. Subnet Mask The Subnet Mask determines which portion of a Destination IP Address is the network portion, and which portion is the host portion. Gateway This is the IP address of the gateway device that allows for contact between the Gateway and the remote network or host. Hop Count This is the number of hops to each node until the destination is reached (16 hops maximum). Enter the appropriate Hop Count. Click Show Routing Table to view the static routes you have already set up.
Advanced Routing
NAT
Enabled/Disabled If this Gateway is hosting your networks connection to the Internet, keep the default, Enabled. If another gateway or router exists on your network, select Disabled.
Routing Table
For each route, the Destination LAN IP address, Subnet Mask, Gateway, and Interface are displayed. Click Refresh to update the information. Click Close to exit this screen. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Dynamic Routing
RIP This feature enables the Gateway to automatically adjust to physical changes in the networks layout and exchange routing tables with the other router(s). The Gateway determines the network packets route based on the fewest number of hops between the source and the destination. Select Enabled to use the Dynamic Routing feature. Otherwise, keep the default, Disabled. RIP Version Select the appropriate protocol version, RIP1 or RIP2.
Static Routing
A static route is a pre-determined pathway that network information must travel to reach a specific host or network. Enter the information described below to set up a new static route. Select set number To set up a static route between the Gateway and another network, select a number from the drop-down list. Click Delete This Entry to delete a static route.
Wireless-G ADSL Gateway with SpeedBooster 12
Chapter 4
Advanced Configuration
by the Gateway. If you want to broadcast the Gateways SSID, keep the default, Enable. Otherwise, select Disable. Wireless SES Function If you want to allow use of the SecureEasySetup (SES) feature, keep the default, Enable. Otherwise, select Disable. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
There are two ways to configure the Gateways wireless settings, manual and SecureEasySetup. For manual configuration, use this screen to change the settings. SecureEasySetup is a feature that makes it easy to set up your wireless network. If you have devices that support SecureEasySetup, run the Gateways Setup Wizard CD-ROM and follow the on-screen instructions to use SecureEasySetup. NOTE: SecureEasySetup ONLY uses WPA-Personal with TKIP security. If your current wireless devices do not support WPA-Personal security OR you want to use WPA2 security, then you cannot use SecureEasySetup on your network. You need to manually configure the security settings for your wireless network.
Wireless Security
Security Mode Select the security method for your wireless network. Proceed to the appropriate instructions. If you do not want to use wireless security, keep the default, Disabled. NOTE: If you are using wireless security, remember that each device in your wireless network MUST use the same security method and settings, or else the wireless devices cannot communicate.
Wireless Network
Wireless Network Mode Select the wireless standards running on your network. If you have Wireless-G and Wireless-B devices in your network, keep the default, Mixed. If you have only Wireless-G devices, select G-Only. If you have only Wireless-B devices, select B-Only. If you do not have any wireless devices, select Disabled. Wireless Network Name (SSID) The network name is case-sensitive and must not exceed 32 characters (use any of the characters on the keyboard). Linksys recommends that you change the default, linksys, to a unique name of your choice. Wireless Channel Select the channel you want to use. All devices in your wireless network must use the same channel in order to communicate. Wireless SSID Broadcast When wireless devices survey the local area for wireless networks to associate with, they will detect the wireless network name or SSID broadcast
Wireless-G ADSL Gateway with SpeedBooster
WPA2-Personal
Chapter 4
Advanced Configuration
WEP
Passphrase Enter a Passphrase (also called a WPA shared key) of 8-63 characters. Key Renewal Enter a Key Renewal period, which instructs the Gateway how often it should change the encryption keys. The default is 3600 seconds.
WPA2-Mixed
Encryption Select a level of WEP encryption, 64-bit or 128-bit. Passphrase Enter a Passphrase to automatically generate WEP keys. Then click Generate. NOTE: The WEP Passphrase is compatible with Linksys wireless products only. If you are use nonLinksys products, manually enter the appropriate WEP key on those devices. WEP Key 1-4 If you did not enter a Passphrase, enter the WEP key(s) manually. TX Key Select which TX (Transmit) Key to use. The default is 1. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Encryption TKIP + AES is automatically selected. Passphrase Enter a Passphrase (also called a WPA shared key) of 8-63 characters. Key Renewal Enter a Key Renewal period, which instructs the Gateway how often it should change the encryption keys. The default is 3600 seconds.
WPA-Personal
Encryption WPA supports two encryption methods, TKIP and AES, with dynamic encryption keys. Select the type of algorithm, TKIP or AES. The default is TKIP. Passphrase Enter a Passphrase (also called a WPA shared key) of 8-63 characters. Key Renewal Enter a Key Renewal period, which instructs the Gateway how often it should change the encryption keys. The default is 3600 seconds.
Wireless > Wireless Access
14
Chapter 4
Advanced Configuration
Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Access. If you do not wish to filter users by MAC address, keep the default, Allow All. Prevent listed computers from accessing the wireless network Select this to block wireless access by MAC address. This setting is selected by default. Permit only listed computers to access the wireless network Select this to allow wireless access by MAC address. Update Filter List Click this to open the MAC Address Filter List screen.
Advanced Wireless
Authentication Type The default is Auto, which allows either Open System or Shared Key authentication to be used. With Open System authentication, the sender and the recipient do NOT use a WEP key for authentication. With Shared Key authentication, the sender and recipient use a WEP key for authentication. Select Shared Key to only use Shared Key authentication. Control TX Rate The Control TX Rate should be set depending on the speed of your wireless network. Select from a range of transmission speeds, or keep the default, Auto. When the Auto setting is selected, the Gateway automatically uses the fastest possible data rate and enables the Auto-Fallback feature, which negotiates the best possible connection speed between the Gateway and a wireless device. Wireless Afterburner To improve wireless performance when the Gateway is used with devices that support SpeedBooster, keep the default, Enable. Otherwise, select Disable.
Wireless Client List
MAC 01-20 Enter the MAC addresses of the devices whose wireless access you want to block or allow. Wireless Client MAC List Click this to open the Wireless Client List screen.
Beacon Interval Enter a value between 1 and 65,535 milliseconds. The Beacon Interval value indicates the frequency interval of the beacon. A beacon is a packet broadcast by the Gateway to synchronize the wireless network(s). The default value is 100. DTIM Interval This value, between 1 and 255, indicates the interval of the Delivery Traffic Indication Message (DTIM). A DTIM field is a countdown field informing clients of the next window for listening to broadcast and multicast messages. When the Gateway has buffered broadcast or multicast messages for associated clients, it
15
Chapter 4
Advanced Configuration
Filter Java Applets Java is a programming language for websites. If you deny Java, you run the risk of not having access to Internet sites created using this programming language. Select Filter Java Applets to enable Java filtering. Deselect the feature to allow Java usage. Filter Cookies A cookie is data stored on your computer and used by Internet sites when you interact with them. Select Filter Cookies to filter cookies. Deselect the feature to allow cookie usage. Filter ActiveX ActiveX is a programming language for websites. If you deny ActiveX, you run the risk of not having access to Internet sites created using this programming language. Select Filter ActiveX to enable ActiveX filtering. Deselect the feature to allow ActiveX usage.
sends the next DTIM with a DTIM Interval value. Its clients hear the beacons and awaken to receive the broadcast and multicast messages. The default value is 1. Fragmentation Threshold This value specifies the maximum size for a packet before data is fragmented into multiple packets. If you experience a high packet error rate, you may slightly increase the Fragmentation Threshold. Setting the Fragmentation Threshold too low may result in poor network performance. Only minor reduction of the default value is recommended. In most cases, it should remain at its default value of 2346. RTS Threshold Should you encounter inconsistent data flow, only minor reduction of the default, 2346, is recommended. If a network packet is smaller than the preset RTS threshold size, the RTS/CTS mechanism will not be enabled. The Gateway sends Request to Send (RTS) frames to a particular receiving station and negotiates the sending of a data frame. After receiving an RTS, the wireless station responds with a Clear to Send (CTS) frame to acknowledge the right to begin transmission. The RTS Threshold value should remain at its default value of 2346. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Firewall
SPI Firewall Protection To use firewall protection, keep the default selection, Enable. To turn off firewall protection, select Disable.
VPN Passthrough
IPSec Passthrough Internet Protocol Security (IPSec) is a suite of protocols used to implement secure exchange of packets at the IP layer. To allow IPSec tunnels to pass through the Gateway, keep the default, Enable. PPTP Passthrough Point-to-Point Tunneling Protocol (PPTP) allows the Point-to-Point Protocol (PPP) to be tunneled through an IP network. To allow PPTP tunnels to pass through the Gateway, keep the default, Enable.
Additional Filters
Filter Proxy Use of WAN proxy servers may compromise the Gateways security. Denying Proxy will disable access to any WAN proxy servers. Select Filter Proxy to enable proxy filtering. Deselect the feature to allow proxy access.
Wireless-G ADSL Gateway with SpeedBooster
16
Chapter 4
Advanced Configuration
L2TP Passthrough Layer 2 Tunneling Protocol is the method used to enable Point-to-Point sessions via the Internet on the Layer 2 level. To allow L2TP tunnels to pass through the Gateway, keep the default, Enable. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Status Policies are disabled by default. To enable a policy, select the policy number from the drop-down menu, and select Enable. To create a policy, follow steps 1-11. Repeat these steps to create additional policies, one at a time. 1. Select a number from the Internet Access Policy dropdown menu. 2. To enable this policy, select Enable. 3. Enter a Policy Name in the field provided. 4. Click Edit List of PCs to select which computers will be affected by the policy. The Internet Access PC List screen appears. You can select a computer by MAC address or IP address. You can also enter a range of IP addresses if you want this policy to affect a group of computers. After making your changes, click Save Settings to apply your changes, or click Cancel Changes to cancel your changes. Then click Close.
Summary
The policies are listed with the following information: No., Policy Name, Days, and Time of Day. To delete a policy, select Delete. To return to the Internet Access Policy screen, click Close.
17
Chapter 4
Advanced Configuration
5. Select the appropriate option, Deny or Allow, depending on whether you want to block or allow Internet access for the computers you selected on the Internet Access PC List screen. 6. Decide which days and what times you want this policy to be enforced. Select the individual days during which the policy will be in effect, or select Everyday. Then enter a range of hours and minutes during which the policy will be in effect, or select 24 Hours. 7. You can block websites with specific URL addresses. Enter each URL in a separate Website Blocking by URL Address field. 8. You can also block websites using specific keywords. Enter each keyword in a separate Website Blocking by Keyword field. 9. You can filter access to various services accessed over the Internet, such as FTP or telnet. From the Blocked Services list, select the service you want to block. The port numbers and protocol for the selected service are automatically displayed. 10. If the service you want is not listed, select UserDefined. Enter its port numbers in the fields provided. Then select its protocol: ICMP, TCP, UDP, or TCP & UDP from the drop-down menu. 11. Click Save Settings to save the policys settings. To cancel the policys settings, click Cancel Changes.
Applications and Gaming > Single Port Forwarding
18
Chapter 4
Advanced Configuration
Applications & Gaming > Port Range Triggering
The Port Range Triggering screen allows the Gateway to watch outgoing data for specific port numbers. The IP address of the computer that sends the matching data is remembered by the Gateway, so that when the requested data returns through the Gateway, the data is pulled back to the proper computer by way of IP address and port mapping rules.
When users send these types of requests to your network via the Internet, the Gateway will forward those requests to the appropriate servers (computers). Before using forwarding, you should assign static IP addresses to the designated servers. If you need to forward all ports to one computer, click the DMZ tab.
Chapter 4
Advanced Configuration
QoS (Quality of Service)
QoS To use QoS, select Enable. Otherwise, keep the default, Disable.
because it only opens the ports you want to have opened, while DMZ hosting opens all the ports of one computer, exposing the computer to the Internet.
Application-based QoS
Application-based QoS manages information as it is transmitted and received. Depending on the settings of the QoS screen, this feature will assign information a high, medium, or low priority for the five preset applications and three additional applications that you specify. The five preset applications are the following:
DMZ
Any computer whose port is being forwarded must have its DHCP client function disabled and should have a new static IP address assigned to it because its IP address may change when using the DHCP function. DMZ Hosting To disable DMZ hosting, keep the default, Disable. To expose one PC, select Enable. Then configure the following setting: DMZ Host IP Address Enter the IP address of the computer. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
FTP (File Transfer Protocol) A protocol used to transfer files over a TCP/IP network (Internet, UNIX, etc.). For example, after HTML pages are developed for a website on a local machine, they are typically uploaded to the web server using FTP. HTTP (HyperText Transport Protocol) The communications protocol used to connect to servers on the World Wide Web. Its primary function is to establish a connection with a web server and transmit HTML pages to the client web browser. Telnet A terminal emulation protocol commonly used on Internet and TCP/IP-based networks. It allows a user at a terminal or computer to log onto a remote device and run a program. SMTP (Simple Mail Transfer Protocol) The standard e-mail protocol on the Internet. It is a TCP/IP protocol that defines the message format and the message transfer agent (MTA), which stores and forwards the mail. POP3 (Post Office Protocol 3) A standard mail server commonly used on the Internet. It provides a message store that holds incoming e-mail until users log on and download it. POP3 is a simple system with little selectivity. All pending messages and attachments are downloaded at the same time. POP3 uses the SMTP messaging protocol.
Specific Port# You can add three more applications by entering their respective port numbers in these fields. High priority/Medium priority/Low priority For each application, select High priority (traffic on this queue shares 60% of the total bandwidth), Medium priority (traffic on this queue shares 18% of the total bandwidth), or Low priority (traffic on this queue shares 1% of the total bandwidth). Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Applications and Gaming > QoS Wireless-G ADSL Gateway with SpeedBooster 20
Chapter 4
Advanced Configuration
NOTE: When you are in a remote location and wish to manage the Gateway, enter http://<Internet_IP_address>:port. Enter the Gateways specific Internet IP address in place of <Internet_IP_address>, and enter the Management Port number in place of the word port.
SNMP
SNMP is a popular network monitoring and management protocol. Device Name Enter the name of the Gateway. SNMP To use SNMP, select Enable. Otherwise, select Disable. Get Community Enter the password that allows readonly access to the Gateways SNMP information. Set Community Enter the password that allows read/write access to the Gateways SNMP information. Trap Management: Trap to Enter the IP address of the remote host computer that will receive the trap messages.
Gateway Access
Local Gateway Access
To ensure the Gateways security, you will be asked for your username and password when you access the Gateways web-based utility. The default username and password are admin. Gateway Userlist Select the number of the user. The default is user 1. Gateway Username Enter Username, admin. the default Gateway
UPnP
Universal Plug and Play (UPnP) allows Windows XP and Vista to automatically configure the Gateway for various Internet applications, such as gaming and videoconferencing. UPnP If you want to use UPnP, keep the default, Enable. Otherwise, select Disable.
WLAN
If you are using the Gateway in a public domain where you are giving wireless access to your guests, you can disable wireless access to the Gateways web-based utility. Management via WLAN This feature allows the Gateway to be managed by a wireless computer on the local network when it logs into the Gateways web-based utility. You will only be able to access the utility via a wired connection if you disable this feature. To allow wireless access to the utility, keep the default, Enable. Otherwise, select Disable. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Gateway Password Linksys recommends that you change the default Gateway Password, admin, to one of your choice. Re-enter to Confirm Enter the Gateway Password again to confirm. For non-admin users, select a different user number, and then configure the Gateway Username and Password settings.
21
Chapter 4
Advanced Configuration
Log
Type Select ALL, Access Log, or Firewall Log. Click pageRefresh to update the log. Click Clear to clear all the information that is displayed. Click Previous Page to view the previous page of information. Click Next Page to view the next page of information. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
Reporting
Log To disable the Log function, keep the default, Disable. To monitor traffic between the network and the Internet, select Enable. With logging enabled, you can choose to view temporary logs. E-Mail Alerts To enable E-Mail Alerts, select Enable. Denial of Service Thresholds Enter the number of Denial of Service attacks that will trigger an e-mail alert. SMTP Mail Server Enter the IP address of the SMTP server. E-Mail Address for Alert Logs Enter the e-mail address that will receive alert logs. Return E-Mail address Enter the return address for the e-mail alerts. (This can be a dummy address.) View Log To view the logs, click View Log.
Administration > Diagnostics
Ping Test
Ping Test Parameters
The ping test checks the status of a connection. Ping Target IP Enter the IP address that you want to ping. This can be either a local (LAN) or Internet (WAN) IP address. Ping Size Enter the packet size you want to use. The default is 60 bytes. Number of Pings Enter how many times you want to ping. The default is 1. Ping Interval Enter the number of milliseconds between pings. The default is 1000 milliseconds. Ping Timeout Enter the number of milliseconds before the ping test will time out. The default is 5000 milliseconds. Start Test To run the test, click this button. The Ping Test screen will show if the test was successful. Click Close to return to the Diagnostics screen.
22
Chapter 4
Advanced Configuration
Administration > Factory Defaults
The Administration > Factory Defaults screen allows you to restore the Gateways configuration to its factory default settings.
Ping Result The results of the ping test are displayed. Click Save Settings to apply your changes, or click Cancel Changes to cancel your changes.
NOTE: Restoring factory defaults deletes custom settings. Note your custom settings before restoring the factory defaults.
Factory Defaults
Restore Factory Defaults To reset settings to the default values, click this button and follow the on-screen instructions. Any custom Gateway settings you have saved will be lost when the default settings are restored.
Backup Configuration
Backup To save the Gateways settings in a configuration file, click this button and follow the on-screen instructions.
Restore Configuration
To use this option, you must have previously backed up its configuration settings. Please select a file to restore Click the Browse button and select the Gateways configuration file. Restore To restore the Gateways configuration settings, click this button and follow the on-screen instructions.
Administration > Firmware Upgrade
23
Chapter 4
Advanced Configuration
on the Internet connection type selected on the Basic Setup screen. Click Refresh to update the on-screen information.
NOTE: The Gateway may lose the settings you have customized. Before you upgrade its firmware, write down all of your custom settings. After you upgrade its firmware, you will have to reenter all of your configuration settings.
Firmware Upgrade
Before upgrading the firmware, download the Gateways firmware upgrade file from the Linksys website, www.linksys.com/international. Then extract the file. Language Select the language you want the web-based utility to use: English, French, or German. The web-based utility will change to the new language five seconds after you select it. Please Select a File to Upgrade Click Browse and select the extracted firmware upgrade file. Start to Upgrade After you have selected the appropriate file, click this button, and follow the on-screen instructions.
Local Network
MAC Address The MAC address of the Gateways local, wired interface is displayed. IP Address The Gateways IP address, as it appears on your local network, is displayed. Subnet Mask The Subnet Mask of the Gateway is displayed.
DHCP Server
DHCP Server The status of the Gateways DHCP server function is displayed. Start IP Address For the range of IP addresses used by devices on your local network, the starting IP address is displayed.
Status > Gateway
End IP Address For the range of IP addresses used by devices on your local network, the ending IP address is displayed. DHCP Client Table Click this button to view a list of devices that are using the Gateway as a DHCP server.
Gateway Information
Firmware Version The version number of the Gateways current firmware is displayed. MAC Address The Gateways MAC address, as seen by your ISP, is displayed. Current Time The time set on the Gateway is displayed.
Internet Connection
This section shows the current network information stored in the Gateway. The information varies depending
DHCP Active IP Table Wireless-G ADSL Gateway with SpeedBooster 24
Chapter 4
Advanced Configuration
Wireless
Firmware Version The version number of the firmware is displayed. MAC Address The wireless MAC address of the Gateways local, wireless interface is displayed. Mode The wireless network mode of the Gateway is displayed. SSID The wireless network name, which is also called the SSID, is displayed. Channel The channel of the wireless network is displayed. Encryption Function The wireless security method is displayed. Wireless Clients Connected Click this button to view a list of wireless clients connected to the Gateway.
ARP/RARP Table
ARP/RARP Table
An ARP request is a request sent by the Gateway asking local network devices with IP addresses for their MAC addresses, so the Gateway can map IP addresses to MAC addresses. RARP is the reverse of ARP. (This data is stored in temporary memory and changes periodically.) To retrieve the most up-to-date information, click Refresh. To exit this screen and return to the Local Network screen, click Close.
Networked Computers
Networked Computers
The list of wireless devices displays Computer Name, IP Address, and MAC Address. To retrieve the most up-todate information, click Refresh. To exit this screen and return to the Wireless screen, click Close.
25
Chapter 4
Advanced Configuration
DSL Connection
Status The status of the DSL connection is displayed. Downstream Rate The download speed of traffic from the Internet to the Gateway is displayed. Upstream Rate The upload speed of traffic from the Gateway to the Internet is displayed. For ADSL connection, the Upstream Rate is typically 25% of the Downstream Rate. NOTE: The Downstream and Upstream Rates are affected by distance from and configuration of the DSL central office.
PVC Connection
Encapsulation The Encapsulation setting selected on the Basic Setup screen is displayed. DSL Modulation Mode The DSL Modulation Mode selected on the Basic Setup screen is displayed. Multiplexing The Multiplexing setting selected on the Basic Setup screen is displayed. Qos The QoS method selected on the Basic Setup screen is displayed. PCR Rate The PCR Rate value entered on the Basic Setup screen is displayed. SCR Rate The SCR Rate value entered on the Basic Setup screen is displayed. Autodetect The Autodetect setting selected on the Basic Setup screen is displayed. VPI The VPI value entered on the Basic Setup screen is displayed. VCI The VCI value entered on the Basic Setup screen is displayed. Enable The number of Permanent Virtual Circuits (PVC) is displayed. PVC Status The status of the PVC is displayed.
26
Appendix A
Troubleshooting
You need to modify the basic settings on the Gateway. Run the Setup Wizard on the Setup CD-ROM. You need to modify the advanced settings on the Gateway. Open the web browser (for example, Internet Explorer or Firefox), and enter the Gateways IP address in the address field (the default IP address is 192.168.1.1). When prompted, complete the User name and Password fields (the default user name and password is admin). Click the appropriate tab to change the settings.
Appendix A: Troubleshooting
Your computer cannot connect to the Internet. Follow the instructions until your computer can connect to the Internet:
Make sure that the Gateway is powered on. The Power LED should be green and not flashing. If the Power LED is flashing, then power off all of your network devices, including the Gateway and computers. Then power on each device in the following order: 1. 2. Gateway Computer
Check the LEDs on the front panel of the Gateway. Make sure the Power, DSL, and at least one of the numbered LEDs are lit. If they are not, then check the cable connections. The computer should be connected to one of the ports numbered 1-4 on the Gateway, and the Line port of the Gateway must be connected to the ADSL line.
When you double-click the web browser, you are prompted for a username and password. If you want to get rid of the prompt, follow these instructions. Launch the web browser and perform the following steps (these steps are specific to Internet Explorer but are similar for other browsers): 1. 2. 3. 4. Select Tools > Internet Options. Click the Connections tab. Select Never dial a connection. Click OK.
You are using a static IP address and cannot connect. Refer to Windows Help, and change your Internet Protocol (TCP/IP) Properties to Obtain an IP address automatically. The computer cannot connect wirelessly to the network. Make sure the wireless network name or SSID is the same on both the computer and the Gateway. If you have enabled wireless security, then make sure the same security method and key are used by both the computer and the Gateway.
27
Appendix B
Specifications
Appendix B: Specifications
Model Number Standards Ports Button Cabling Type LEDs Transmit Power UPnP able/cert WAG54GS IEEE 802.11g, IEEE 802.11b, IEEE 802.3u, IEEE 802.3, g.992.1 (g.dmt), g.992.2 (g.lite), g.992.3, g.992.5, T1.413i2, U-R2 for Annex B Power, Line, Ethernet (1-4) Reset, Power, SES (SecureEasySetup) CAT 5 UTP Power, Wireless, Ethernet (1-4), DSL, Internet, SecureEasySetup 18 dBm Able
Security Features Password-Protected Configuration for Web Access WEP Key Bits PAP and CHAP Authentication Denial of Service (DoS) Prevention URL Filtering, and Keyword, Java, ActiveX, Proxy, Cookie Blocking ToD Filter (Blocks Access by Time) VPN Passthrough for IPSec, PPTP, and L2TP Protocols 128, 64 Bits WEP with Passphrase WEP Key Generation, WPA, WPA2 SSID Broadcast Disable Access Restriction by MAC and IP Addresses 64, 128 140 x 140 x 27 mm 270 g 12VDC 1A CE -20 to 70C 10 to 85% Noncondensing
Environmental
Dimensions Weight Power Certification Storage Temp. Operating Humidity
28
Appendix C
Warranty Information
TO THE EXTENT NOT PROHIBITED BY LAW, IN NO EVENT WILL LINKSYS BE LIABLE FOR ANY LOST DATA, REVENUE OR PROFIT, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL OR PUNITIVE DAMAGES, REGARDLESS OF THE THEORY OF LIABILITY (INCLUDING NEGLIGENCE), ARISING OUT OF OR RELATED TO THE USE OF OR INABILITY TO USE THE PRODUCT (INCLUDING ANY SOFTWARE), EVEN IF LINKSYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL LINKSYS LIABILITY EXCEED THE AMOUNT PAID BY YOU FOR THE PRODUCT. The foregoing limitations will apply even if any warranty or remedy provided under this Agreement fails of its essential purpose. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to You. This Warranty is valid and may be processed only in the country of purchase. Please direct all inquiries to: Linksys, P.O. Box 18558, Irvine, CA 92623.
29
Appendix D
Regulatory Information
Industry Canada Statement
This device complies with Industry Canada ICES-003 and RSS210 rules. Operation is subject to the following two conditions: 1. This device may not cause interference and 2. This device must accept any interference, including interference that may cause undesired operation of the device. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the EIRP is not more than required for successful communication.
Reorient or relocate the receiving antenna Increase the separation between the equipment or devices Connect the equipment to an outlet other than the receivers Consult a dealer or an experienced radio/TV technician for assistance
Safety Notices
Caution: To reduce the risk of fire, use only No.26 AWG or larger telecommunication line cord. Do not use this product near water, for example, in a wet basement or near a swimming pool. Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
30
Appendix D
Regulatory Information
Dit apparaat voldoet aan de essentiele eisen en andere van toepassing zijnde bepalingen van de Richtlijn 1999/5/EC. Dan l-apparat huwa konformi mal-tiiet essenzjali u l-provedimenti l-ora rilevanti tad-Direttiva 1999/5/EC. Ez a kszlk teljesti az alapvet kvetelmnyeket s ms 1999/5/EK irnyelvben meghatrozott vonatkoz rendelkezseket. Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-direktiv 1999/5/EF. Urzdzenie jest zgodne z oglnymi wymaganiami oraz szczeglnymi warunkami okrelonymi Dyrektyw UE: 1999/5/EC. Este equipamento est em conformidade com os requisitos essenciais e outras provises relevantes da Directiva 1999/5/EC. Acest echipament este in conformitate cu cerintele esentiale si cu alte prevederi relevante ale Directivei 1999/5/EC. Ta naprava je skladna z bistvenimi zahtevami in ostalimi relevantnimi pogoji Direktive 1999/5/EC. Toto zariadenie je v zhode so zkladnmi poiadavkami a inmi prslunmi nariadeniami direktv: 1999/5/EC. Tm laite tytt direktiivin 1999/5/EY olennaiset vaatimukset ja on siin asetettujen muiden laitetta koskevien mrysten mukainen. Denna utrustning r i verensstmmelse med de vsentliga kraven och andra relevanta bestmmelser i Direktiv 1999/5/EC.
Magyar [Hungarian]:
Norsk [Norwegian]: Polski [Polish]: Portugus [Portuguese]: Romn [Romanian] Slovensko [Slovenian]: Slovensky [Slovak]:
Deutsch [German]:
Eesti [Estonian]:
English:
Espaol [Spanish]: [Greek]: Franais [French]: slenska [Icelandic]: Italiano [Italian]: Latviski [Latvian]: Lietuvi [Lithuanian]:
Suomi [Finnish]:
Svenska [Swedish]:
For all products, the Declaration of Conformity (DofC) is available through one or more of these options:
A pdf file is included on the products CD. A print copy is included with the product. A pdf file is available on the products webpage. Visit www.linksys.com/international and select your country or region. Then select your product.
If you need any other technical documentation, see the Technical Documents on www.linksys.com/international section, as shown later in this appendix.
31
Appendix D
Regulatory Information
National Restrictions
This product may be used in all EU countries (and other countries following the EU directive 1999/5/EC) without any limitation except for the countries mentioned below: Ce produit peut tre utilis dans tous les pays de lUE (et dans tous les pays ayant transposs la directive 1999/5/CE) sans aucune limitation, except pour les pays mentionns cidessous: Questo prodotto utilizzabile in tutte i paesi EU (ed in tutti gli altri paesi che seguono le direttive EU 1999/5/EC) senza nessuna limitazione, eccetto per i paesii menzionati di seguito: Das Produkt kann in allen EU Staaten ohne Einschrnkungen eingesetzt werden (sowie in anderen Staaten die der EU Direktive 1999/5/CE folgen) mit Aunahme der folgenden aufgefhrten Staaten: In the majority of the EU and other European countries, the 2,4- and 5-GHz bands have been made available for the use of wireless local area networks (LANs). The table labeled Overview of Regulatory Requirements for Wireless LANs provides an overview of the regulatory requirements applicable for the 2,4 and 5-GHz bands. Later in this document you will find an overview of countries in which additional restrictions or requirements or both are applicable. The requirements for any country may evolve. Linksys recommends that you check with the local authorities for the latest status of their national regulations for both the 2,4- and 5-GHz wireless LANs.
Overview of Regulatory Requirements for Wireless LANs
The following standards were applied during the assessment of the product against the requirements of the Directive 1999/5/EC:
Radio: EN 300 328 and/or EN 301 893 as applicable EMC: EN 301 489-1, EN 301 489-17 Safety: EN 60950 and either EN 50385 or EN 50371
Dynamic Frequency Selection (DFS) and Transmit Power Control (TPC) are required for operation in the 5 GHz band. DFS: The equipment meets the DFS requirements as defined in ETSI EN 301 893. This feature is required by the regulations to avoid interference with Radio Location Services (radars). TPC: For operation in the 5 GHz band, the maximum power level is 3 dB or more below the applicable limit. As such, TPC is not required.
CE Marking
For the Linksys Wireless-N, -G, -B, and/or -A products, the following CE mark, notified body number (where applicable), and class 2 identifier are added to the equipment.
or
or
or
Indoor ONLY
Check the CE label on the product to find out which notified body was involved during the assessment.
5150-5350 5470-5725
X X
The following countries have restrictions and/or requirements in addition to those given in the table labeled Overview of Regulatory Requirements for Wireless LANs:
Denmark
In Denmark, the band 5150 - 5350 MHz is also allowed for outdoor usage. I Danmark m frekvensbndet 5150 - 5350 ogs anvendes udendrs.
Wireless-G ADSL Gateway with SpeedBooster 32
Appendix D
Regulatory Information
Product Usage Restrictions
This product is designed for indoor usage only. Outdoor usage is not recommended, unless otherwise noted.
France
For 2,4 GHz, the product should not be used outdoors in the band 2454 - 2483,5 MHz. There are no restrictions when used in other parts of the 2,4 GHz band when used indoors. Check http://www.arcep.fr/ for more details. Pour la bande 2,4 GHz, l quipement ne doit pas tre utilis en extrieur dans la bande 2454 - 2483,5 MHz. Il ny a pas de restrictions pour des utilisations en intrieur dans dautres parties de la bande 2,4GHz. Consultez http://www.arcep.fr/ pour de plus amples dtails.
Applicable Power Levels in France
Location
Indoor (No restrictions) Outdoor
Power (EIRP)
100 mW (20 dBm) 100 mW (20 dBm) 10 mW (10 dBm)
Italy
This product meets the National Radio Interface and the requirements specified in the National Frequency Allocation Table for Italy. Unless this 2,4-GHz wireless LAN product is operating within the boundaries of the owners property, its use requires a general authorization. Please check http://www.comunicazioni.it/it/ for more details. Questo prodotto conforme alla specifiche di Interfaccia Radio Nazionali e rispetta il Piano Nazionale di ripartizione delle frequenze in Italia. Se non viene installato allinterno del proprio fondo, lutilizzo di prodotti Wireless LAN a 2,4 GHz richiede una Autorizzazione Generale. Consultare http://www.comunicazioni.it/it/ per maggiori dettagli.
Latvia
The outdoor usage of the 2,4 GHz band requires an authorization from the Electronic Communications Office. Please check http://www.esd.lv for more details. 2,4 GHz frekveu joslas izmantoanai rpus telpm nepiecieama atauja no Elektronisko sakaru direkcijas. Vairk informcijas: http://www.esd.lv. Notes: 1. Although Norway, Switzerland and Liechtenstein are not EU member states, the EU Directive 1999/5/EC has also been implemented in those countries. 2. The regulatory limits for maximum output power are specified in EIRP. The EIRP level of a device can be calculated by adding the gain of the antenna used (specified in dBi) to the output power available at the connector (specified in dBm).
Wireless-G ADSL Gateway with SpeedBooster
33
Appendix D
Regulatory Information
Cetina (Czech) - Informace o ochran ivotnho prosted pro zkaznky v zemch Evropsk unie
Evropsk smrnice 2002/96/ES zakazuje, aby zazen oznaen tmto symbolem na produktu anebo na obalu bylo likvidovno s netdnm komunlnm odpadem. Tento symbol udv, e dan produkt mus bt likvidovn oddlen od bnho komunlnho odpadu. Odpovdte za likvidaci tohoto produktu a dalch elektrickch a elektronickch zazen prostednictvm urench sbrnch mst stanovench vldou nebo mstnmi ady. Sprvn likvidace a recyklace pomh pedchzet potencilnm negativnm dopadm na ivotn prosted a lidsk zdrav. Podrobnj informace o likvidaci starho vybaven si laskav vydejte od mstnch ad, podniku zabvajcho se likvidac komunlnch odpad nebo obchodu, kde jste produkt zakoupili.
User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE)
This document contains important information for users with regards to the proper disposal and recycling of Linksys products. Consumers are required to comply with this notice for all electronic products bearing the following symbol:
(Bulgarian) -
2002/96/EC , / , . , . . . - , , .
34
Appendix D
Regulatory Information
Franais (French) - Informations environnementales pour les clients de lUnion europenne
La directive europenne 2002/96/CE exige que lquipement sur lequel est appos ce symbole sur le produit et/ou son emballage ne soit pas jet avec les autres ordures mnagres. Ce symbole indique que le produit doit tre limin dans un circuit distinct de celui pour les dchets des mnages. Il est de votre responsabilit de jeter ce matriel ainsi que tout autre matriel lectrique ou lectronique par les moyens de collecte indiqus par le gouvernement et les pouvoirs publics des collectivits territoriales. Llimination et le recyclage en bonne et due forme ont pour but de lutter contre limpact nfaste potentiel de ce type de produits sur lenvironnement et la sant publique. Pour plus dinformations sur le mode dlimination de votre ancien quipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des dchets, ou lendroit o vous avez achet le produit.
Italiano (Italian) - Informazioni relative allambiente per i clienti residenti nellUnione Europea
La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sullimballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. responsabilit del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per lambiente e per la salute dellessere umano. Per ricevere informazioni pi dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto.
(Greek) -
2002/96/EC / . . . . , , .
35
Appendix D
Regulatory Information
Nederlands (Dutch) - Milieu-informatie voor klanten in de Europese Unie
De Europese Richtlijn 2002/96/EC schrijft voor dat apparatuur die is voorzien van dit symbool op het product of de verpakking, niet mag worden ingezameld met niet-gescheiden huishoudelijk afval. Dit symbool geeft aan dat het product apart moet worden ingezameld. U bent zelf verantwoordelijk voor de vernietiging van deze en andere elektrische en elektronische apparatuur via de daarvoor door de landelijke of plaatselijke overheid aangewezen inzamelingskanalen. De juiste vernietiging en recycling van deze apparatuur voorkomt mogelijke negatieve gevolgen voor het milieu en de gezondheid. Voor meer informatie over het vernietigen van uw oude apparatuur neemt u contact op met de plaatselijke autoriteiten of afvalverwerkingsdienst, of met de winkel waar u het product hebt aangeschaft.
Polski (Polish) - Informacja dla klientw w Unii Europejskiej o przepisach dotyczcych ochrony rodowiska
Dyrektywa Europejska 2002/96/EC wymaga, aby sprzt oznaczony symbolem znajdujcym si na produkcie i/lub jego opakowaniu nie by wyrzucany razem z innymi niesortowanymi odpadami komunalnymi. Symbol ten wskazuje, e produkt nie powinien by usuwany razem ze zwykymi odpadami z gospodarstw domowych. Na Pastwu spoczywa obowizek wyrzucania tego i innych urzdze elektrycznych oraz elektronicznych w punktach odbioru wyznaczonych przez wadze krajowe lub lokalne. Pozbywanie si sprztu we waciwy sposb i jego recykling pomog zapobiec potencjalnie negatywnym konsekwencjom dla rodowiska i zdrowia ludzkiego. W celu uzyskania szczegowych informacji o usuwaniu starego sprztu, prosimy zwrci si do lokalnych wadz, sub oczyszczania miasta lub sklepu, w ktrym produkt zosta nabyty.
36
Appendix D
Regulatory Information
Slovenina (Slovene) - Okoljske informacije za stranke v Evropski uniji
Evropska direktiva 2002/96/EC prepoveduje odlaganje opreme, oznaene s tem simbolom na izdelku in/ali na embalai med obiajne, nerazvrene odpadke. Ta simbol opozarja, da je treba izdelek odvrei loeno od preostalih gospodinjskih odpadkov. Vaa odgovornost je, da to in preostalo elektrino in elektronsko opremo odnesete na posebna zbiralia, ki jih doloijo dravne ustanove ali lokalna uprava. S pravilnim odlaganjem in recikliranjem boste prepreili morebitne kodljive vplive na okolje in zdravje ljudi. e elite izvedeti ve o odlaganju stare opreme, se obrnite na lokalno upravo, odpad ali trgovino, kjer ste izdelek kupili.
Slovenina (Slovak) - Informcie o ochrane ivotnho prostredia pre zkaznkov v Eurpskej nii
Poda eurpskej smernice 2002/96/ES zariadenie s tmto symbolom na produkte a/alebo jeho balen nesmie by likvidovan spolu s netriedenm komunlnym odpadom. Symbol znamen, e produkt by sa mal likvidova oddelene od benho odpadu z domcnost. Je vaou povinnosou likvidova toto i ostatn elektrick a elektronick zariadenia prostrednctvom pecializovanch zbernch zariaden urench vldou alebo miestnymi orgnmi. Sprvna likvidcia a recyklcia pome zabrni prpadnm negatvnym dopadom na ivotn prostredie a zdravie ud. Ak mte zujem o podrobnejie informcie o likvidcii starho zariadenia, obrte sa, prosm, na miestne orgny, organizcie zaoberajce sa likvidciou odpadov alebo obchod, v ktorom ste si produkt zakpili.