Professional Documents
Culture Documents
disabled persons.
10%
800mm (0.80m)
At least ___ unit/s of public telephones for every __ unit/s shall be accessible to disabled persons and shall be provided with visual aids.
Length of wheelchairs.
1.10 to 1.30m
Width of wheelchairs.
0.60 to 0.75m
A circle of ___meters in diameter is a suitable guide in the planning of wheelchair turning spaces.
1.50 m
Comfortable reach of persons confined to wheelchairs is from ____ to ____above the floor.
0.70 to 1.20 m
Comfortable clearance for knee and leg space under tables for wheelchair users is ____.
0.74 m
This shall refer to buses having minimum seating capacity of 50 persons for regular buses and 40 persons for air-con buses.(Includes regular and air-con city and provincial buses, aircon tourist and provincial buses.
Land Transportation
This shall refer to the 3 railway systems in the country, the PNR, PRC Panay Railways Corp, and LRTA.
Rail Transportation
This shall refer to domestic passenger ships, ferry boats and other passenger carrying water transportation.
Water Transportation
Air Transportation
RA 7277
Immediate Deportation
It refers to features that enable disabled persons to make use of the primary functions for which a structure is built.
Accessible
Anthropometric
It is a strip fastened to the floor beneath a door, usually required to cover the joint where two types of floor materials meet..
Threshold
A small entranceway or transitional space from the exterior to the interior of a building and opens into a larger space.
Vestibule
Passageway or passage
An exterior passage for walking along, especially one connecting adjoining building and related structures.
Walkway
dropped curb
0.90 m
1:12
1:20
25 mm
1:20 or 5%
1:100
1.20 m
Walkways headroom
2.00 m or higher
1.00 to 1.06m
A ___ meters long extension of the handrail should be provided at the start and end of ramps and stairs.
0.30 m
30mm to 50mm
Handrails attached to walls should have a clearance of not less than___ from the wall.
50mm
40mm
2.00 m
tactile
3.70 m
A walkway from accessible spaces of ____clear width shall be provided between the front ends of parked cars.
1.20 m
Entrance with vestibules shall be provided a level area with at least a ____depth and _____width.
1.20 m
1:12
The length of the ramp should not exceed ______ if the gradient is 1:12.
6.00 m
Longer ramps whose gradient is 1:12 shall be provided with landings not less than ___.
1.50 m
A level area not less than ____ should be provided at the top and bottom of any ramp.
1.80 m
Handrails will be provided on both sides of the ramp at ___ and ____ from the ramp level.
0.10 m
0.80 m
Doors should be operable by a pressure or force not more than ____; the closing device pressure an interior door shall not exceed____.
A minimum clear level space of ____ shall be provided before and extending beyond a door.
1.50 m x 1.50 m
0.90 m
Vertical pull handles, centered at ____above the floor are preferred to horizontal pull bars for swig doors or doors with locking devices.
1.06 m
Doors along major circulation routes should be provided with kick plates made of durable material at a height of _____to ______.
0.30m to 0.40 m
25mm
1.20m to 1.30m
1.20 m
Turnabout spaces have a minimum area of ___X ___ and shall be spaced at a maximum of ___.
Turnabout spaces should also be provided at or within ____ of every dead end.
3.50 m
1.70 m X 1.80 m
(1) one w.c if total w.c on the floor is 20. (2) two w.c if the total w.c on the floor exceeds 20.
0.45 m
1.20 m
0.80 m
0.48 m
A tactile strip ___ wide shall be installed before hazardousareas such as sudden changes in floor levels and at the top and bottom of stairs.
0.30 m
30 m
1.10 m x 1.40 m
Distance from the floor of Control panels and emergency system of accessible elevators.
0.90 m x 1.20 m
Button sizes at elevator control panels shall have a minimum diameter of ___and should have a maximum depression depth of ___.
20mm ; 1mm
0.35 m
1.20 m
For residential occupancies, the provision of ____-alarms for all occupants who are either deaf or hearing impaired shall be compulsory.
Vibra
Walkway gradient.
1:20 or 5%
1:100
1mm
At least 1 water fountain shall be provided for every ____sqm of floor area and there shall be at least one on each floor.
2000