B 900 mm B 900 mm

D 230 mm D 230 mm
Fck 30 N/mm2 Fck 35 N/mm2
X 4.522 M X 4.522 M
Y 4.37 M Y 4.37 M
d 150 mm d 150 mm
SW 3.75 kN/m2 SW 3.75 kN/m2
SDL 2 kN/m2 SDL 2 kN/m2
LL 2 kN/m2 LL 2 kN/m2
TOTAL LOAD 7.75 kN/m2 TOTAL LOAD 7.75 kN/m2
Acrp 399000 mm2 Acrp 399000 mm2
0.399 M2 0.399 M2
A 19.76114 M2 A 19.76114 M2
Aeff 19.36214 M2 Aeff 19.36214 M2
bo1 2860 mm bo1 2860 mm
S 150.056585 Kn S 150.056585 Kn
150056.585 N 150056.585 N
c 0.876356092 N/mm2 c 0.946572765 N/mm2
v
0.349782249 N/mm2
v
0.349782249 N/mm2
PUNCHING SHEAR CHECK
COLUMN C1
CONCRETE GRADE OF SLAB
SLAB SPAN SUPPORTED BY COLUMN
SLAB DEPTH
PERMISSIBLE SHEAR STRESS
PUNCHING SHEAR AT CRITICAL SECTION
SAFE IN PUNCHING SHEAR
COLUMN C1
CONCRETE GRADE OF SLAB
CRITICAL AREA FOR COLUMN PUNCHING
AREA SUPPORTED BY COLUMN
EFFECTIVE AREA OF LOADING FOR PUNCHING
PERIMETER OF CRITICAL SECTION OF PUNCHING
SHEAR FORCE AT CRITICAL SECTION
PERMISSIBLE SHEAR STRESS
LOAD ON SLAB SUPPORTED BY COLUMN
CRITICAL AREA FOR COLUMN PUNCHING
AREA SUPPORTED BY COLUMN
EFFECTIVE AREA OF LOADING FOR PUNCHING
PERIMETER OF CRITICAL SECTION OF PUNCHING
SHEAR FORCE AT CRITICAL SECTION
PUNCHING SHEAR AT CRITICAL SECTION
SAFE IN PUNCHING SHEAR
PUNCHING SHEAR CHECK
SLAB SPAN SUPPORTED BY COLUMN
SLAB DEPTH
LOAD ON SLAB SUPPORTED BY COLUMN