You are on page 1of 4

DESIGN OF BEAMS

Fcu =

300

Fy =

kg\cm2

* d=C1(Mu/(Fcu*b)).5

BEAM
SEC1
SEC2
SEC3
SEC4
SEC5
SEC6
SEC7
SEC8
SEC9
SEC10
SEC11
SEC12
SEC13
SEC14
SEC15
SEC16
SEC17
SEC18
SEC19
SEC20
SEC21

T
100
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
70
70
70
70
70

b
30
30
12
12
12
12
12
12
12
25
12
12
12
12
12
12
12
12
12
12
12

Mw

Mu
34.90
6.10
2.40
4.70
8.10
9.00
2.00
4.40
3.10
3.40
4.40
6.50
3.30
1.00
23.00
3.00
3.00
3.00
3.00
3.00
3.00

SEC.
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r

B
30
30
12
12
12
12
12
12
12
25
12
12
12
12
12
12
12
12
12
12
12

C1
4.95
9.41
9.49
6.78
5.17
4.90
10.40
7.01
8.35
11.51
7.01
5.77
8.09
14.70
3.07
8.49
7.39
7.39
7.39
7.39
7.39

cover =
ts =

kg\cm2

2.5

cm
cm

16*ts+b

11*b*d/Fy TAKE THE


MIN.
1.3 As req VALUE TAKE THE
MAX.
.15%*b*d
VALUE

* As min.=

* As=Mu/(J*Fy*d)

4600

* FOR T SEC. : B =

C.L -- C.L.

TAKE THE
MIN.
VALUE.

K*L/5+b
(for L sec.:(6ts+b,K*L\10+b)
J
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.826
0.749
0.826
0.826
0.826
0.826
0.826
0.826

As
27.2
2.1
0.8
1.6
2.8
3.1
0.7
1.5
1.1
1.2
1.5
2.2
1.1
0.3
8.6
1.0
1.2
1.2
1.2
1.2
1.2

Asmin
27.20
3.49
1.40
2.07
2.22
2.22
1.40
1.94
1.40
2.91
1.94
2.22
1.46
1.40
2.22
1.40
1.52
1.52
1.52
1.52
1.52

f(mm)
22
12
12
12
12
12
12
12
12
12
12
12
12
12
12
18
18
18
18
18
18

NO. OF STEEL
8
4
2
2
3
3
2
2
2
3
2
2
2
2
8
2
2
2
2
2
2

By:EN.AHMED MORSI

DESIGN OF BEAMS
CHECK SHEAR :
* qcu =0.75(Fcu/gc)0.5

10.61

kg\cm2

* qumax. =2.20(Fcu/gc)0.5

31.11

kg\cm2

qu
1.37
3.35
8.60
9.14
9.68
10.22
10.75
12.90
21.51
7.46
10.65
11.61
9.40
6.67
0.00
0.00
0.00
0.00
0.00
0.00
0.00

CHECK
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
NEED SHEAR RFT
NEED SHEAR RFT
NEED SHEAR RFT
USE MIN. RFT
NEED SHEAR RFT
NEED SHEAR RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT
USE MIN. RFT

TAKE THE

* qsu = qu-qcu/2 = n*As*Fy/gc/(b*S)

(n=4)

* qu=Qu/(b*d) kg\m2

BEAM
SEC1
SEC2
SEC3
SEC4
SEC5
SEC6
SEC7
SEC8
SEC9
SEC10
SEC11
SEC12
SEC13
SEC14
SEC15
SEC16
SEC17
SEC18
SEC19
SEC20
SEC21

Qw

Qu
4.00
7.80
8.00
8.50
9.00
9.50
10.00
12.00
20.00
14.46
9.90
10.80
8.74
6.20

qsu
5.45
7.60
16.20
5.34
6.31
-

f(mm)
8
8
8
8
8
8
8
8
8
10
8
8
8
8
8
8
8
8
8
8
8

Fy
2400
2400
2400
2400
2400
2400
2400
2400
2400
3600
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400
2400

S (cm)
20.00
20.00
20.00
20.00
20.00
20.00
32.07
22.99
10.79
20.00
32.71
27.70
20.00
20.00
20.00
20.00
20.00
20.00
20.00
20.00
20.00

NO. of STIR.\m\
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8
4
f
8
5
f
8
10
f
8
5
f
10
4
f
8
4
f
8
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8
5
f
8

n
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

By:EN.AHMED MORSI

DESIGN OF BEAMS
IN CASE OF USED BENT BARS
* qb. =Asb*(Fy/gs)*sin45/(b/d)
* qb.<=0.75(Fcu\gc)0.5

Fy =

3600

kg\cm2

NO. of STIR.
f

* qdes. =qu-qcu/2-qb

BEAM
SEC1

BENT BARS
f(mm)

NO.
3

22

Asb
11.40

qb
8.63

qdes.
0.00

f(mm)
8

Fy
2400

S (cm)
-

n
2

By:EN.AHMED MORSI

FOT T , L SEC.

6*TS+b
BEAM
SEC1

L
1.88

K
0.67

16*TS+b
-

K*L/10+b
C.L. -- C.L.
4

K*L/5+b
-

MIN.
-

By:EN.AHMED MORSI