You are on page 1of 324

For over sixty years the ROHN name has been a leader in the telecommunications industry.

The company has used our expertise in structural design and fabrication to expand into
additional markets. ROHN is proud to service the major utility and wind energy companies
in North America. These markets are just two of the latest to join telecom, sports lighting,
broadband, broadcast and the others that have been using ROHN Products to support their
infrastructure projects for six decades.
This year we are proud to ofer the latest version of the ROHN Products Catalog (No. 2). There
have been some major changes to the layout. Some of the changes to Catalog No. 2 are
listed below.
ROHNs Utility Structure business continues to grow. We have added pre-engineered
utility structures to Catalog No. 2 on pages 227-234.
The ROHN model 45G guyed tower now includes the ROHN 45GSR (solid legs and
braces).
The ROHN model 65G guyed tower is now available with Rev G standard designs.
Camera towers are now available in knocked down and all welded sections, starting
on page 172.
ROHN steel tubing can be purchased for special projects, see page 301.
If you have any questions, comments or suggestions regarding this catalog or any ROHN
products, we are just a phone call away. On the adjacent page we have listed contacts that can
assist you with any questions.
ROHN is committed to providing you the best products in the industry. Our towers are
standing on every continent and in nearly every country around the world. That is because
we are recognized around the globe as the quality leader in structures. We strive to continue
that tradition this year and in the years to come.
We appreciate your interest in our products and we appreciate your business.

Thank you for your interest in ROHN Products
-The ROHN Team-
The Industry Standard
Since 1948
The information contained in this catalog is intended to assist customers in selecting the appropriate ROHN product
for specifc applications. The information, drawings, etc. are not intended to be substituted for assembly drawings
provided with a ROHN product. Dimensions and weights provided in this catalog are nominal. Refer to our website
www.rohnnet.com for additional information and products.
HOW T O OR DE R
I
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
1
S A L E S T E R R I T OR I E S
ORDERS ORIGINATING IN WESTERN UNITED STATES
ORDERS ORIGINATING IN CENTRAL UNITED STATES & WIND ENERGY
ORDERS ORIGINATING IN EASTERN UNITED STATES
INTERNATIONAL TELECOM & BROADCAST (Outside of U.S.)
Joel Stone
309.566.3007
joel.stone@rohnnet.com
Scott Burdette
309.566.3010
scott.burdette@rohnnet.com
Ken Cordrey
410.822.8964
ken.cordrey@rohnnet.com
Sabet Borairi
905.339.4016
sabet.borairi@rohnnet.com
TRANSPORTATION & UTILITY
Jeff Arends
309.566.3004
jeff.arends@rohnnet.com
TELECOMMUNICATIONS & BUILD-TO-SUIT
Paul Michaud
763.767.9550
paul.michaud@rohnnet.com
For general information or comments, please contact us at (800) 727-ROHN or info@rohnnet.com
I
TA B L E OF CONT E NT S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
2
Company History
Industries We Serve
Understanding TIA-222 - Revision G
GUYED TOWERS
G-Series Towers
25G | General Use & Features
Standard Designs (90mph | 110mph | 130mph)
Parts & Accessories
Grounding & Foundations
45G | General Use & Features
Standard Designs (90mph | 110mph | 130mph)
Parts & Accessories
Grounding & Foundations
45GSR | General Use & Features
Standard Designs (90mph | 110mph | 130mph)
Parts & Accessories
Grounding & Foundations
45GSR Meteorological Towers | General Use & Features
55G | General Use & Features
Standard Designs (90mph | 110mph | 130mph)
Parts & Accessories
Grounding & Foundations
65G | General Use & Features
Standard Designs (90mph | 110mph | 130mph)
Parts & Accessories
Grounding & Foundations
General Notes for G-Series Guyed Towers
G-Series Foundation General Notes
Guy Arrangement Details
Guy Connection Details
Assembly Bolt Installation
80 | General Use & Features
90 | General Use & Features
REV. G
includes
REV. F&
6
7-12
13-20
21-157
22-23
24-25
26-36
37-40
41-44
46-47
48-62
63-65
66-69
70-71
72-91
92
93-97
98-99
100-101
102-114
115-116
117-120
122-123
124-140
141-142
143-146
147
147-149
150
151-152
153
154-155
156-157
TA B L E OF CONT E NT S
I
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
3
SELF-SUPPORTING TOWERS
G-Series Self-Supporting | General Use & Features
G-Series Self-Supporting Loading Charts - No Ice [Rev F]
G-Series Self-Supporting Loading Charts - No Ice [Rev G]
Design Notes & Foundation Information
65G Camera Tower
Standard Foundation Details & Accessories
VG Camera Tower
Standard Foundation Details & Accessories
RSL | General Use & Features
Standard Designs (20 - 100)
Accessories
Base Kit
Grounding Information
Foundation Information
SSV | General Use & Features
Standard Loading Chart
Standard Section Detail
Standard Foundations
SSV - Heavy Duty| General Use & Features
Standard Loading Chart
Standard Section Detail
Standard Foundations
SSMW | General Use & Features
Standard Section Detail
SSVSR | General Use & Features
Stadard Section Detail
RS | General Use & Features
Standard Section Detail

TOWER & SITE ACCESSORIES
Side Arms
Leg Dish Mounts
Tie-Back Assemblies
Face Dish Mounts
Sector Mount
BRACKETED TOWERS
G-Series Bracketed Towers | General Use & Features
25G Bracketed Tower & Foundation
45G Bracketed Tower & Foundation
55G Bracketed Tower & Foundation
159-163
160
161
162
163
165-199
166
167
168
169-170
172
173
174
175
176
177-183
183-184
185
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
201-218
202
203
204
205-206
207
TELESCOPING MASTS
General Description
Mast Details
H20 Typical Guy Layout
H30 Typical Guy Layout
H40 Typical Guy Layout
H50 Typical Guy Layout
9H50 Typical Guy Layout
Parts & Accessories
POLES
Direct Embed Poles | General Use & Features
Standard Loading Charts
Accessories
Antenna Index
Pre-Engineered Utility Poles | General Use & Features
Standard Loading Charts
Accessories
Utility Structure Information
Transportation Structure Information
Wind Turbine Structures
I
TA B L E OF CONT E NT S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
4
ROOF MOUNTS
Effective Wind Velocity Formula Sheet
FRM
JRM
BRM4
BRM6
NPPK
25GBRM
AAGM
PRM6
Ballast Requirements
URM
TOWER & SITE ACCESSORIES [continued]
Rotor Plate Assemblies
Safety Device & Safety Cable
Climbing Ladders
Waveguide Ladders
Waveguide Brackets
Waveguide Bridges
201-218
208
209
210
211-213
214-216
217-218
219-241
220
221-224
225
226
227
228-233
234
236-237
238-239
240-241
243-249
244
245
246
246
247
247
248
249
251-273
252
253
254-256
257-259
260-263
264
265-266
267-268
269
270
271
TA B L E OF CONT E NT S
I
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
5
INFORMATION
Construction Services
Considerations, Recommendations & Safety Information
Erection
Recommendations for Communication Tower Specifications
Guidelines for Preparing a Geotechnical Report
General Safety Information
Terms & Conditions of Sale
GENERAL TOWER HARDWARE
Nuts, Bolts & Washers
Guy Material
Grounding
Steel Tubing & Mounting Pipe
Miscellaneous
TOWER LIGHTING GUIDELINES
Style A
Style B
Style C
Style D / Style E
Style F
ROOF MOUNTS [continued]
SHRM
TRT
WALL MOUNTS
1LG
PWM
WM4 / WM212 / Extended Mounts
G-Series Wall Mounts
251-273
272
273
275-279
276
277
278
279
281-288
282-285
286-287
288
289-302
290-295
295-298
299
300-301
302
303-308
304
305
306
307
308
309-317
310
311
312
313
314
315-316
317
TOWER MODIFICATION MATERIAL
Guyed Towers
Self-Supporting Towers
Guy Anchor Selection Chart
I
T HE COMPA NY
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
6
HI S T OR Y
Founded in 1948, in Peoria, Illinois by Dwight Rohn, the ROHN product quickly became
the industry standard for towers. The need for ROHN structures grew out of the television
industry and a need for homeowners to have small towers adjacent to their homes to
enable signal reception. The demand grew quickly and the companys knowledge and
capacity were forced to grow with it. Soon television reception towers grew into radio
towers, microwave towers, lighting structures and more. When the cellular technology
exploded in the U.S., ROHN was there to provide the towers to support the rapid growth.
This growth was not just in markets but in geographies.
By 1980, ROHN had structures standing on every continent and in nearly every country
on the globe. We continue to supply towers and poles to all of the communication giants
and regional carriers. We support utilities and transportation in all of North America. We
have wind turbine towers and meteorological towers across the globe. For over 60 years,
our products have endured and our name continues to be recognized around the world
as the industry standard.
B R OA DC A S T S OL UT I ONS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
7
2011 ROHN PRODUCTS LLC
When Americans turned on their frst television sets, ROHN was there
to improve fuzzy reception with our home antenna tower. During the
40s and 50s, a ROHN TV tower installed on a rooftop or in a backyard
meant that familys TV reception was the best on the block, even if the
picture was only black and white and the screen just 12 inches wide.
ROHNs business serves the broadcast side of TV as well. With the advent
of digital TV and compliance with FCC standards, broadcasters are
choosing to remain competitive by expanding their services into more
areas. To do so, they look to ROHN to deliver Tall Towers, super structures
rising as high as 2,000 feet, to broadcast TV signals to millions of viewers
in a much wider geographic area.
ROHN towers are some of the tallest structures in the world, and we build
each tower in accordance with our exacting standards for quality,
performance and structural integrity. Our tall towers are helping change
the way the world receives and views television signals. This innovation
is nothing new for ROHN. Back in 1948 when we started our business,
we were on the forefront of the television age. Today, we stand ready to
serve the next wave of television broadcasting.
R OHN S OL UT I ONS
WI R E L E S S S OL UT I ONS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
8
2011 ROHN PRODUCTS LLC
I
ROHN has been supplying towers to the wireless industry since the industry
was born. Whether the application is microwave, cellular, PCS or broadband,
we have the towers in service supporting wireless communications.
When the frst microwave towers were constructed in the United States,
ROHN was the quality supplier of choice. We designed and fabricated to the
most stringent standards for wind, ice and dish twist and sway requirements.
As the communication system progressed to cellular, then PCS, ROHN was
again leading the market with our ROHN SSV towers serving as the industry
preference for wireless sites.
ROHN continues to support wireless communication from microwave to
broadband communications. Our structures are still the leaders in the industry.
ROHN also ofers a variety of steel poles to meet your specifc communication
needs. Our tapered and fanged steel poles feature designs that are
aesthetically pleasing and blend well into the environment while requiring
minimum space for installation. All of our steel poles are hot-dip galvanized
after fabrication to ensure years of corrosion free use. As one of the largest
manufacturers of communication structures, with unmatched attention to
detail and design, our steel poles provide an extremely efcient design.
ROHNs steel poles meet the stringent demands of todays communication
environment.
S P OR T S L I GHT I NG S OL UT I ONS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
9
2011 ROHN PRODUCTS LLC
Whatever your application - from little league baseball to a major league
sports stadium, ROHN has a steel pole to do the job. Poles are available
with the traditional anchor base or for direct embedment. ROHNs
engineering staf will select the proper pole based on your specifc
requirements, considering wind speed, luminaire size, weight and quantity.
For decades, ROHN has supplied sports lighting structures. ROHN towers
support lights for the Anaheim Angels professional baseball team, the
University of Illinois football team and the Peoria Chiefs, the local minor
league baseball team near our plant location in Peoria, IL.
All poles and towers are hot-dip galvanized and our direct embed poles
can be purchased with an extra subsurface corrosion resistant coating.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
T R A NS P OR TAT I ON S OL UT I ONS
10
2011 ROHN PRODUCTS LLC
ROHN has been a trusted name in quality-engineered structures since
1948. We have the people, equipment and experience to provide the
materials you need for your transportation structure projects. ROHN
Mast Arms, Monotube Assemblies, Steel Strain Poles and Sign Structures
are designed and manufactured to AASHTO standards. Our products can
be supplied galvanized, painted over galvanizing or factory fnished
powder coated. We are dedicated to delivering quality products, on time
at a competitive price; whether it is a single pole or multiple pole project.
ROHN has over 300,000 square feet of manufacturing located in Peoria,
Illinois. ROHNs manufacturing is certifed by both the American Institute
of Steel Construction (Dual AISC Certifed Steel Fabricator - Buildings
and Simple Steel Bridges) and the Canadian Welding Bureau.
ROHN uses specialized engineering software coupled with ROHN developed
software for the design of tubular structures and foundations. This
allows ROHN to optimize pole designs based on customer requirements,
manufacturing efciencies and material availability. Preliminary
calculation packages are sent to our customers for review with bid
packages.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
11
2011 ROHN PRODUCTS LLC
UT I L I T Y S OL UT I ONS
I
R OHN S OL UT I ONS
ROHN can optimize pole designs based on customer requirements,
calculation packages are sent to our customers for review and approval
prior to manufacturing. Fabrication and erection drawings are produced
in AutoCAD and accompany the structures we produce. Our commitment
to the utility industry is to provide the highest quality products with
the shortest lead time.
ROHN uses Power Line Systems software coupled with ROHN developed
software for the design of tubular structures and foundations. This
allows us to optimize the pole designs based on customer requirements.
ROHNs state of the art equipment and facility allows us to fabricate the
After the pole shafts have been formed on our press brake, they pass
through ROHNs custom built seam welder. The shafts are then completed
plays a key role in the manufacturing process for latticed towers with our
CNC plate processors, machining center, anglematics and beam lines that
can process angle up to 8 x 8 x 1 1/4.
ROHNs Quality Assurance/Quality Control program begins when the
material is received at our plant, ensuring that all material meets the
throughout the manufacturing process to ensure that they are within the
engineering and manufacturing tolerances. All full penetration base
Because of ROHNs commitment to customer service, the Inside Sales
Manager assigned to your project will work closely with you to assure
your order is designed and built to the highest standards and delivered
just as you ordered it. We understand the importance of on-time delivery
and constantly strive to exceed your expectations. Our plant is centrally
located in Peoria, Illinois, which allows for competitive freight costs.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
WI ND E NE R GY S OL UT I ONS
12
2011 ROHN PRODUCTS LLC
ROHN has extensive experience in manufacturing meteorological and
turbine support structures for wind energy applications. Whatever the
requirement, poles, towers or guyed masts, we have used our products
to support this industry.
Our structures are used to support wind turbines ranging up to 50 kW.
ROHN structures are hot-dip galvanized where the components are
totally immersed in molten zinc, inside and out, to ensure years of corrosion
protection. Our steel pole designs are aesthetically pleasing, while requiring
minimum space for installation.
To ensure that ROHN meets the demand of todays wind energy customer,
our steel poles ofer extremely efcient designs and unmatched attention
to detail. For over 60 years, ROHN has manufactured support structures
with great care and design excellence.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
UNDE R S TA NDI NG T I A - 2 2 2 - R E V I S I ON G
14
2011 ROHN PRODUCTS LLC
What is Rev G?
Rev G is the latest revision of the TIA-222 Standard Structural Standards for Antenna Supporting Structures and Antennas.
The previous version of the Standard was Rev F. Rev G is based on a 3-second gust wind speed and Rev F is based on a fastest-
mile wind speed. The wind speeds are not directly comparable and it is very important to defne the basis of a wind speed
when specifying wind loading requirements. For a given location, the 3-second gust wind speed represents the peak gust
wind speed whereas the fastest-mile wind speed represents the average wind speed over the time required for one mile of
wind to pass the site.
Rev G presents additional factors to be considered in the design of new structures and for the modifcation of existing
structures. These factors are briefy discussed below. The reliability requirements of a structure can now be accounted for by
assigning a classifcation to a structure (Class I, II or III). The wind speed can also be adjusted based on the type of terrain
surrounding the site (Exposure B, C or D) and if the site is located on a hill, ridge or escarpment (Topographic Category 1-5).
Many tower profles in this catalog now include antenna loading capacities for both Exposure B and Exposure C terrain
conditions located on relatively fat sites (Topographic Category 1). Antenna loading capacities in accordance with Rev F
are also provided for many tower profles in the catalog. Please refer to the design notes in the catalog for each tower model
series for further explanations. The Class of structure is stated in the design notes. Conditions other than stated may require
a diferent tower profle than illustrated in this catalog. Quotes may be obtained for a specifc application by contacting your
ROHN representative.
Classifcation of Structures
Allows for the adjustment of wind, ice and earthquake loading to match the reliability requirements for a specifc application.
Three reliability classes have been established based on the type of service provided and on the structures potential
hazard to human life and property. Wind, ice and earthquake loading progressively increase from Class I to Class III structures.
Class I: Structures used for services where a delay in returning the service would be acceptable and the structure represents a
low hazard to human life and/or property. Example services would be: residential wireless and conventional 2-way radio
communications; television, radio and scanner reception; wireless cable, amateur and CB radio communications. Structures
of this classifcation are exempt from ice and earthquake loading.
Class II: Structures used for services that may be provided by other means or structures that represent a signifcant hazard to
human life and/or property. Example services would be: commercial wireless communications; television and radio
broadcasting; cellular, PCS, CATV and microwave communications.
Class III: Structures specifcally designed for essential communications or structures that represent a substantial hazard to
human life and/or property. Examples of essential communications would be: civil or national defense; emergency, rescue
or disaster operations; military and navigational facilities.
What is EPA?
EPA stands for Efective Projected Area. It is a standard way to defne the size of an antenna regarding wind loading. Many
antenna manufacturers provide data sheets that specify the EPA of their antennas. The TIA standard also defnes a method
to calculate the EPA of an antenna based on the size and type of the antenna components.
Generally, the EPA of an antenna, mount or accessory is equal to the summation of the projected areas of its components times
appropriate drag factors defned in the TIA Standard. The EPA values listed in this catalog for standard tower designs represents
the maximum EPA that may be supported unless otherwise indicated.
UNDE R S TA NDI NG T I A - 2 2 2 - R E V I S I ON G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
15
2011 ROHN PRODUCTS LLC
What is Exposure?
Exposure categories are used to adjust wind loading based on the type of terrain surrounding a site. Reduced wind loads are
associated with rougher terrains that tend to slow the wind down. Three exposure categories have been defned based on
terrain roughness. Wind loading is increased as the exposure designation changes from Exposure B (roughest terrain) to
Exposure D (smoothest terrain).
Exposure B: Urban, suburban or wooded areas. The wind load at ground level is reduced compared to Exposure C. This
reduction diminishes with height, making the overall wind reduction less signifcant for taller structures. In order to qualify for
the wind load reduction, the rough terrain must extend in all directions from the site at least twenty times the height of the
structure, but not less than one-half mile.
Exposure C: Flat, open country and grasslands.
Exposure D: Flat, unobstructed shorelines exposed to wind fowing over open water, smooth mud fats, salt fats and other
similar terrain. The wind load at ground level is increased compared to Exposure C.
Topographic Categories
Topographic categories are used to determine increases in wind loading for sites located on hills and other elevated locations
(other than buildings). The shape and relative height (topography) of an elevated site determines the increase in wind load.
Although many elevated sites have their own unique features, the intent is to idealize these sites into one of the standard
topography categories described below.
The height of an elevated site above the surrounding terrain must be specifed in order to determine the increase in wind
loading. Height should not be confused with the elevation of the site. As described below, elevations of the site and the
surrounding terrain must be used to determine the relative height of a site. For structures supported on buildings, it is only
necessary to specify the height of the building and the surrounding exposure category.
Category 1: Flat or rolling terrain with no abrupt changes in general topography. No increase in wind loading is required for
this category.
Category 2: Sites separated from a lower elevation by a gently sloping terrain (escarpment). Wind loads at the crest are 2.0
times the wind loads for a fat site and diminish with height depending on the height of the escarpment.
Height for an escarpment is the diference in elevation between the upper and lower levels. Increased wind loads do not apply
for structures located in the lower half of the sloping terrain or located beyond 16 times the escarpments height from the crest.
Category 3: Sites located at the top or within the upper half of a hill. Wind loads at the top of a hill are 2.3 times the wind loads
for a fat site and diminish with height depending on the relative height of the hill.
Height for a hill is the diference in elevation between the top and bottom of the hill. For sites surrounded by other hills, height
is the diference in the hill elevation at the site and the average elevation of the surrounding hills (within a 2-mile radius).
In other words, height is the projection of the hill exposed to wind. When there are other hills surrounding the site, increased
wind loads do not apply unless the height of the hill at the tower site is at least 2 times the average height of the surrounding
hills. (Refer to sketch above.)
Topographic Categories continued on next page.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
UNDE R S TA NDI NG T I A - 2 2 2 - R E V I S I ON G
16
2011 ROHN PRODUCTS LLC
Elevation 2,150
Elevation 1,550
Elevation 1,250
Average Elevation of
Surrounding Features
2 Mile Radius 2 Mile Radius
3
0
0

6
0
0

H = 2,150 - 1,550 = 600


Wind speed-up must be considered when H exceeds
2 times the average height of surrounding features.
Category 4: Sites located on a ridge. Wind loads at the top of a ridge are 3 times the wind loads for a fat site and diminish with
height depending on the height of the ridge.
Height for a ridge is the diference between the top and bottom elevations of the ridge.
Category 5: This category is reserved for sites where site-specifc investigations are performed to determine wind loading. A
site-specifc investigation may result in either higher or lower wind loads compared to using one of the standard topographic
categories.
Height of Site
Average Height
of Surrounding
Terrain
Tower
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
17
2011 ROHN PRODUCTS LLC
Special Wind Region
Location V mph (m/s)
Hawaii 105 (47)
Puerto Rico 145 (66)
Guam 170 (76)
Virgin Islands 145 (65)
American Samoa 125 (56)
Notes:
1. Values are 3-second gust wind speeds in miles per hour (m/s) at 33 ft. (10 m) above ground for Exposure C terrain.
2. Linear interpolation between wind contours is permitted.
3. Islands and coastal areas outside last contour must use the last wind speed contour of the coastal area.
4. Mountainous terrain, gorges, ocean promontories, and special wind regions must be examined for unusual
wind conditions.
R E V G 3 - S E COND B A S I C WI ND S P E E D MA P
The basic wind speed map is being used with permission from ASCE. This material may be used for personal use only.
Any other use requires prior permission of the American Society of Civil Engineers.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
R E V G WI ND S P E E DS
18
2011 ROHN PRODUCTS LLC
The TIA-222-G Standard is based on the wind map published in the ASCE 7-02 Standard, Minimum Design Loads for Buildings
and Other Standards. The ASCE 7 standard is published by the American Society of Civil Engineers (ASCE) and represents the
latest research and data available for wind speeds in the United States.
Subsequent to the release of the TIA-222-G Standard, ASCE has published 2 revisions to the ASCE-7 Standard. The frst revision
was published in 2005 and is designated as ASCE 7-05. There were no changes to the wind map. The second revision was
published in 2010 and is designated as ASCE 7-10. There are changes to the wind map in this version.
The previous versions of ASCE 7 used a 50-year return wind speed map and relied on additional design factors to increase
wind loads according to the reliability requirements of a structure. This resulted in structures being able to survive wind
speeds of much higher return periods. The new wind maps in ASCE 7 -10 now include these design factors and now
represent a much higher return period wind speed. A wind map is provided for each classifcation of structure. No
additional factors have to be considered based on the classifcation of a structure when these wind speeds are used to
calculate wind loads. The new maps can be thought of as Survival wind speeds, or in other words, wind speeds for
which permanent deformation may occur in a structure, but the structure does not collapse.
The new ASCE 7-10 survival wind speeds can be easily converted for use with the TIA-222-G Standard using the following
conversion table. If the conversion is not made, the design factors for determining wind loads will be doubled up resulting
in much higher wind loads than intended. Eventually the TIA Standard and other similar structural standards will be
upgraded to refect the new ASCE 7-10 wind maps. Conversions for fastest-mile wind speeds used in Rev F and
ASCE 7-93 are also included in the table.
Examples to determine appropriate Rev G design criteria:
1. Desire a 95 mph Rev F fastest-mile design. Use a 110 mph Rev G design.
2. Desire a 115 mph ASCE 7-10 design. Use a 90 mph Rev G design.
Design Wind Speed Conversions, MPH
Rev F
ASCE 7-93
(fastest-mile)
71
76
85
90
95
104
114
123
128
133
152
Rev G
ASCE 7-02 & ASCE 7-05
(3-second gust)
85
90
100
105
110
120
130
140
145
150
170
Survival
ASCE 7-10
(3-second gust)
110
115
126
133
139
152
164
177
183
190
215
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
19
2011 ROHN PRODUCTS LLC
R E V G GR OUNDI NG
R E QUI R E ME NT F OR S T R UC T UR E S
Rev G made signifcant changes regarding the grounding requirements for structures. A prescriptive approach to grounding
was used in Rev F where providing specifc grounding leads and ground rods were considered adequate to protect a structure.
Rev G adopted a performance specifcation approach that requires providing a grounding system that will result in a maximum
10 ohm resistance to earth. Rev G also requires minimum ground lead and ground rod sizes that are greater than the Rev F
prescriptive requirements.
Another change is that Rev G does not require specifc grounding materials. Rev F required the use of galvanized ground rods
with tinned copper leads. Rev G only requires that the leads and connections be compatible with the ground rods from a
corrosion standpoint (i.e. minimize diference between metals connected).
Rev G does provide default grounding arrangements for various types of structures that are intended to meet the 10 ohm
requirement for a wide variety of soil conditions. In accordance with Rev G, the actual resistance of a default grounding system
must be verifed based on site conditions. Additional ground rods or special grounding systems may be required.
It should be noted that the TIA-222 grounding requirements are meant to protect the structure and foundation from high
fault currents. Other grounding requirements are often needed for the protection of antennas, radio equipment and other
appurtenances.
Rev G has taken a diferent approach from Rev F regarding standard foundations and the term Normal Soil has been
eliminated. A new term Presumptive Soil has been introduced. Rev G provides for two diferent types of presumptive soil,
sand and clay. Generally the strength of Rev G presumptive soil is lower than the strength of Rev F normal soil.
The intent is to provide default design parameters that can be used to design foundations when a geotechnical report is not
available for a site. In accordance with Rev G, clay is to be considered the default presumptive soil unless more information is
known about a site. The values for clay presumptive soil have therefore been used for the generation of the standard
foundations contained in this catalog.
It should be noted that in accordance with Rev G, actual site conditions must be investigated prior to the installation of a
foundation that was designed using presumptive soil parameters. Modifcations to the standard foundations contained in
this catalog may be required. It should also be noted that Rev G requires a geotechnical investigation for all Class III structures.
One common cause for changes to a standard foundation is due to frost depth. The frost depth for Rev G presumptive soil is
considered to be 3.5 feet. The standard foundations in this catalog are based on this frost depth. Special foundations may be
required for sites in locations where frost depths exceed 3.5 feet and the local soil conditions are susceptible to frost heave.
Presumptive soil also assumes that the water table is below the foundation depth. For this condition, there is no concern for
buoyant conditions that can signifcantly reduce the uplift capacity of a foundation. The standard foundations in this catalog
are based on dry soil conditions and do not consider buoyant conditions. Special foundations may be required for sites where
the water table may rise above the base elevation of the foundation.
In accordance with Rev G, presumptive soils are also considered to be non-corrosive. When local soil conditions are corrosive,
anchors or direct embedded poles that are in direct soil contact may require corrosion protection in addition to hot dip
galvanizing. Rev G provides guidance on various alternatives to consider in these situations.
Presumptive soils are also considered to be non-expansive. Locations known to have expansive soil require special
considerations for foundation design. Modifcations to the standard foundations in this catalog may be required in these
cases.
R E V G S TA NDA R D F OUNDAT I ONS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
R OHN S OL UT I ONS
R E V G C L I MB I NG FAC I L I T I E S
20
2011 ROHN PRODUCTS LLC
Rev G has made signifcant additions addressing climber safety. Two classifcations of climbers have been defned.
An Authorized Climber (also called a Basic Climber) is an individual trained in climbing but may not have had previous
climbing experience. These climbers are intended to be limited to climbing fxed access routes equipped with safety climb
devices. A Competent Climber (also called a Skilled Climber) is a professional who is capable of climbing on structural
members.
Rev G provides requirements for climbing facilities by defning two classes of climbing facilities, Class A and Class B.
Class B requirements are similar to Rev F requirements and are intended for structures to be climbed by professional
Competent Climbers. Class A requirements are more restrictive in comparison to Rev F and are intended for structures
expected to be climbed by lesser qualifed (Basic) climbers. In accordance with Rev G, Class B is considered to be the
default climbing facility requirement for structures unless otherwise specifed. Towers can be quoted to accomodate
Class A climbing facilities when specifed. All ROHN standard structures are intended to be climbed by Competent
Climbers only.
Safety climb systems are now mandatory in accordance with Rev G for structures exceeding 10 feet in height that are
intended to be climbed. Some structures are intended to be maintained by bucket trucks or other methods that do not
involve climbing the structure. Safety climb systems, when required, must be ordered separately for all ROHN standard
structures in this catalog.

The 25G is a light weight tubular tower with solid braces. The tower sections
are most often guyed, but can also be used in bracketed and self-supporting
applications. Standard sections are 10 in length, but are also available in
a 7 length, which is UPS shippable. This tower model has several top
options, as well as a variety of tower accessories. The 25G has several base
options, including: base cast in concrete, base plate with anchor bolts and
also a hinged base.
Standard Design Tower Heights
Guyed: Up to 190
Bracketed: Up to 100
Self-Supporting: Up to 40
25G | 45G | 55G | 65G

The 45G is a light weight tower, available with tubular or solid round legs
with solid braces. The tower sections are most often guyed, but can also be
used in bracketed and self-supporting applications. Standard sections are
10 in length, but are also available in a 20 length when ordering solid
sections. This tower model has several top options, as well as a variety of
tower accessories. The 45G has several base options, including: base cast in
concrete, base plate with anchor bolts and also a hinged base. This tower
is a true multi-use structure.
Standard Design Tower Heights
Guyed: Up to 300 [45G] and 350 [45GSR]
Bracketed: Up to 100
Self-Supporting: Up to 45
25G | 45G | 55G | 65G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
G- S E R I E S T OWE R S
22
2011 ROHN PRODUCTS LLC
ROHN began manufacturing the G-Series line of towers in the early 1950s. Starting with the ROHN No. 5 tower, there was
an ever present drive for a superior tower design. The No. 5 soon led to the ROHN No. 6 and continued through the No.10,
11, 20, 25, 30, 40 and 50 towers. ROHN originally coated the lightweight towers with a hot-dipped enamel coating
called RohnKote. The alternative to RohnKote was hot-dipped galvanizing. The galvanized option was identifed by
the now famous G sufx added to the tower model. The G-Series was born! The numbers have settled to the four
models listed below and hot-dip galvanizing is the coating of choice for towers today.
ROHNs G-Series towers are designed for strength and versatility. The towers are constructed with high strength steel
tubing or solid round legs. ROHNs exclusive Zig-Zag solid-rod bracing provides exceptional strength. As they were in the
1950s, each ROHN G-Series tower continues to be hot-dip galvanized for corrosion protection.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
23
G
G- S E R I E S T OWE R S

The 55G is a tubular tower with solid braces that lends itself to a wide variety
of uses, particularly where unusual wind loading and height requirements
exist. The 55G was designed to provide excellent strength and rigidity. The
tower sections are most often guyed, but can also be used in bracketed and
self-supporting applications. Standard sections are 10 in length. This tower
model has several top options, as well as a variety of tower accessories.
The 55G is available with a base cast in concrete as well as a tapered base
option.
Standard Design Tower Heights
Guyed: Up to 400
Bracketed: Up to 100
Self-Supporting: Up to 60

The 65G is available with tubular or solid round legs with solid braces. The
tower sections are most often guyed, but can also be used in self-supporting
applications. Standard sections are 10 and 20 in length. This tower model
has a variety of tower accessories, and is available with a base cast in concrete
or a tapered base.
Standard Design Tower Heights
Guyed: Up to 500
Self-Supporting: Up to 80
25G | 45G | 55G | 65G
25G | 45G | 55G | 65G
The ROHN G-Series towers are assembled and installed quickly and are diverse enough for use by broadcasters, fre and
police, military, ham and home use. The possibilities are endless with the G-Series towers. Over the long history of the
G-Series, ROHN has developed a variety of options to improve the utility of each model. The G-Series has optional:
Standard and Shortened Sections Double Braced Sections House Brackets
Guy Lug Sections Torque Arms Base Options
Four Leg (Square) Design of 25G Roof Mounts Side Arms
Double Braced Sections Top Mounts
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D 2 5 G GUY E D T OWE R
24
2011 ROHN PRODUCTS LLC
The first. The original.
ROHN 25G
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 40 for ordering information.
REV. G
includes
REV. F&
GENERAL USE
The 25G is available in the standard 10 section
length and a 7 length which is UPS shippable.
The 25G uses double bolted joints, proven to be
the best method of joining tower sections for
sturdiness and dependability. As a guyed
structure, the 25G standard designs rise to a
height of 190.
FEATURES
Completely hot-dip galvanized after fabrication
Built on an 11 1/4 equilateral triangle design
High strength tubular legs joined by Zig-Zag

cross members
Each 7 or 10 section contains all required nuts
and bolts shipped with section
Continuous solid round steel bracing
25G
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all
engineering and warranty data supplied by ROHN. Materials used by others are
not the same quality and have not been tested or engineered by ROHN. Mixing
ROHN tower sections with non-ROHN products may cause tower failure or injury.
CAUTION
1 1/4 O.D.
(16 GA.)
9 9
1 6
STANDARD SECTION
25G - 10 Section
OPTIONAL 7 SECTION
25G7 - 7 Section
The 7 Section is UPS shippable.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D 2 5 G GUY E D T OWE R
S E C T I ONS
25
2.25 O.D.
2.08 I.D.
(14 GA.)
9 3/4
6 1/2
11 1/4
1 1/4 O.D.
(16 GA.)
5/16 O.D.
Solid Bracing
STANDARD TOP SECTION
25AG2
Additional 25G top sections
are shown on page 37.
5/16 O.D.
Solid Bracing
2011 ROHN PRODUCTS LLC
PARTS & ACCESSORIES PAGES 37-40
GROUNDING INFORMATION PAGE 41
FOUNDATION INFORMATION PAGES 41-44
QUICK REFERENCE
CONCRETE BASE PLATE
BPC25G*
FOR USE WITH 3/4X12PP PIER PIN
EMBEDDED IN CONCRETE.
Additional base sections are
available, please see page 38.
1 3
Optional double braced sections
are available upon request.
Optional Waveguide
Brackets (KY2041A)
* Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.
~
~
This document is to serve as a guide for sizing and purchasing the 25G tower. Tower and foundation installations should
be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites
located on unusual terrain.
3. Designs assume two 1/2 diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60 Fahrenheit.
6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 41-44.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
EPA (SQ. FT.), Revision F
P/N 25G90R040

47
35
32
3/16 EHS
(399#)
16.6
22.0
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
22.6
B UY E R S GUI DE
S TA NDA R D DE S I GNS - 2 5 G
9 0 MP H R E V. G [ 3 - S E C ON D G U S T ]
7 0 MP H R E V. F [ FA S T E S T MI L E ]
26
P/N 25G90R040

Tower Model
Windspeed (Rev. G) ROHN Tower
Tower Height (ft.)
EPA= Effective Projected Area
2011 ROHN PRODUCTS LLC
Guy Initial Tension
Design Criteria
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1 1 2
350 12 12 6 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 1 2
425 12 12 6 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 1 2
500 12 12 6 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1 1 3
800 18 18 9 3
3 3 1 3
P/N: 25G90R060
50 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R050
60 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R060
70 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R070
80 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R080
S TA NDA R D DE S I GN - 2 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1 1
175 6 6 3 3
3 3 1 3
40 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R040
P/N: 25G90R040
40 TOWER
35
22.6 16.6
22.0
OR
47
32
3/16EHS
(399#)
P/N: 25G90R050
50 TOWER
45
21.4 15.8
21.0
OR
60
40
3/16EHS
(399#)
46
23
60 TOWER
55
20.3 15.2
20.2
OR
73
48
3/16EHS
(399#)
56
28
P/N: 25G90R070
70 TOWER
65
19.4 14.7
19.4
OR
86
56
3/16EHS
(399#)
64
32
P/N: 25G90R080
80 TOWER
75
18.6 14.3
18.8
OR
99
64
3/16EHS
(399#)
81
50
25 69
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
27
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
FDNS
BASE ANCHOR
FDNS
BASE ANCHOR
FDNS
BASE ANCHOR
FDNS
BASE ANCHOR
CB1G AB2
AB2
AB2
AB2
AB2
CB1G
CB1G
CB1G
CB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
9 1 1 3
1000 18 18 9 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
10 1 1 3
1100 18 18 9 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
11 1 1 4
1575 24 24 12 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
12 1 1 4
1700 24 24 12 3
3 3 1 3
P/N: 25G90R130
100 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 2590R100
110 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R110
120 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R120
130 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R130
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
8 1 1 3
900 18 18 9 3
3 3 1 3
90 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R090
P/N: 25G90R090
90 TOWER
85
18.0 13.9
18.4
OR
111
72
3/16EHS
(399#)
92
57
28 77
P/N: 25G90R100
100 TOWER
95
17.5 13.6
18.0
OR
124
80
3/16EHS
(399#)
102
63
31 86
P/N: 25G90R110
110 TOWER
105
17.0 13.4
17.6
OR
137
88
3/16EHS
(399#)
112
70
35 95
P/N: 25G90R120
120 TOWER
115
16.6 13.1
17.2
OR
150
96
3/16EHS
(399#) 128
85
28 100
55
111
130 TOWER
125
16.2 12.9
17.0
OR
163
104
3/16EHS
(399#) 140
93
31 108
62
121
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
28
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
CB1G
CB1G
CB1G
CB1G
CB1G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
29
2011 ROHN PRODUCTS LLC
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
13 1 1 4
1825 24 24 12 3
3 3 1 3
P/N: 25G90R140
140 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R140
140 TOWER
135
15.9 12.7
16.6
OR
175
112
3/16EHS
(399#) 149
99
33 117
66
130
3/4x12PP
1
FDNS
BASE ANCHOR
AB2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
14 1 1 5
2425 30 30 15 3
3 3 1 3
P/N: 25G90R150
150 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R150
150 TOWER
145
15.5 12.5
16.4
OR
188
120
3/16EHS
(399#)
116
29
58
3/4x12PP
1
FDNS
BASE ANCHOR
AB2
123
133
148
167
87
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
15 1 1 5
2600 30 30 15 3
3 3 1 3
P/N: 25G90R160
160 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R160
160 TOWER
155
15.3 12.3
16.2
OR
201
128
3/16EHS
(399#)
124
31
62
3/4x12PP
1
FDNS
BASE ANCHOR
AB2
132
142
158
178
93
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
16 1 1 5
2750 30 30 15 3
3 3 1 3
P/N: 25G90R170
170 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R170
170 TOWER
165
15.0 12.2
16.0
OR
214
136
3/16EHS
(399#)
132
33
66
3/4x12PP
1
FDNS
BASE ANCHOR
AB2
140
151
168
190
99
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
17 1 1 5
2925 30 30 15 3
3 3 1 3
P/N: 25G90R180
180 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R180
180 TOWER
175
14.8 12.0
15.8
OR
227
144
3/16EHS
(399#)
139
35
69
3/4x12PP
1
FDNS
BASE ANCHOR
AB2
148
160
178
200
105
CB1G
CB1G
CB1G
CB1G
CB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX
18 1 1 5
3075 30 30 15 3
3 3 1
CPC.5/.75
3 P/N: 25G90R190
190 TOWER
185
14.5 11.9
15.6
OR
239
152
3/16EHS
(399#)
212
148
37
156
74
188
111
169
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
30
190 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G90R190
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2 CB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1 1 2
350 12 12 6 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 1 2
425 12 12 6 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 1 2
500 12 12 6 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16 EHS BG2142 5/16 THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1 1 3
800 18 18 9 3
3 3 1 3
50 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R050
60 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R060
70 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R070
80 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R080
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1 1
175 6 6 3 3
3 3 1 3
40 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R040
P/N: 25G110R080
80 TOWER
75
10.9 8.3
11.4
OR
99
64
3/16EHS
(399#)
81
50
25 69
P/N: 25G110R040
40 TOWER
35
13.4 9.7
13.4
OR
47
32
3/16EHS
(399#)
P/N: 25G110R050
50 TOWER
45
12.6 9.1
12.6
OR
60
40
3/16EHS
(399#)
46
22
P/N: 25G110R060
60 TOWER
55
11.9 8.7
12.2
OR
73
48
3/16EHS
(399#)
56
28
P/N: 25G110R070
70 TOWER
65
11.3 8.6
11.8
OR
86
56
3/16EHS
(399#)
64
32
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
31
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
CB1G
CB1G
CB1G
CB1G
CB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
9 1 1 3
1000 18 18 9 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
10 1 1 3
1100 18 18 9 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
11 1 1 4
1575 24 24 12 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
12 1 1 4
1700 24 24 12 3
3 3 1 3
100 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R100
110 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R110
120 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R120
130 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R130
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
8 1 1 3
900 18 18 9 3
3 3 1 3
90 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R090
P/N: 25G110R090
90 TOWER
85
10.5 8.1
11.2
OR
111
72
3/16EHS
(399#)
91
56
28 77
P/N: 25G110R100
100 TOWER
95
10.2 7.9
10.8
OR
124
80
3/16EHS
(399#)
102
63
32 86
P/N: 25G110R110
110 TOWER
105
9.9 7.8
10.6
OR
137
88
3/16EHS
(399#)
112
70
35 95
P/N: 25G110R120
120 TOWER
115
9.7 7.6
10.4
OR
150
96
3/16EHS
(399#) 129
86
28 100
57
112
P/N: 25G110R130
130 TOWER
125
9.3 7.5
10.2
OR
163
104
3/16EHS
(399#) 140
93
31
109
62
121
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
32
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
CB1G
CB1G
CB1G
CB1G
CB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
14 1 1 5
2425 30 30 15 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
15 1 1 5
2600 30 30 15 3
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
16 1 1 6
2800 36 36 6
6 2 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
17 1 1 6
2925 36 36 18 6
6 2 3
GAC3455TOP
150 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R150
160 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R160
170 ROHN 25G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 25G110R170
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
13 1 1 4
1825 24 24 12 3
3 3 1 3
140 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G110R140
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
P/N: 25G110R160
160 TOWER
155
8.8 7.2
9.8
OR
201
128
3/16EHS
(399#)
178
124
31
132
62
158
93
142
P/N: 25G110R150
150 TOWER
145
9.0 7.3
9.9
OR
188
120
3/16EHS
(399#)
167
116
29
123
58
148
87
133
P/N: 25G110R140
140 TOWER
135
9.2 7.4
10.0
OR
175
112
3/16EHS
(399#)
151
101
33 117
67
131
P/N: 25G110R170
170 TOWER
165
8.7 7.1
9.7
OR
136
3/16EHS
(399#)
138
55
83
110
74
28 57
159
175
194
214
P/N: 25G110R180
180 TOWER
176
8.6 7.0
9.6
OR
144
3/16EHS
(399#)
145
58
87
116
77
29 58
168
185
204
227
S TA NDA R D DE S I GN - 2 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
33
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
1/2TBE&J
18
6
6
50
50
GAC3455TOP
GAC3455TOP
GAC3455TOP
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
BASE
INNER
ANCHOR
OUTER
ANCHOR
AB2 AB2
BASE
INNER
ANCHOR
OUTER
ANCHOR
180 ROHN 25G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 25G110R180
AB2 AB2
CB1G
CB1G
CB1G
CB2G
CB2G
18
TBSAFETY 1/2TBE&J
6
CPC.5/.75
6
190 ROHN 25G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 25G110R190
3/4x12PP
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH
AGK1GGX BGK3GGX
18 1 1 6
3100 36 36
3 6 2
P/N: 25G110R190
190 TOWER
186
8.5 6.9
9.5
OR
152
3/16EHS
(399#)
155
62
93
124
80
31 59
178
196
217
240
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
34
50
GAC3455TOP
2011 ROHN PRODUCTS LLC
BASE
INNER
ANCHOR
OUTER
ANCHOR
AB2 AB2 CB2G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1 1
175 6 6 3 3
3 3 1 3
40 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R040
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 1 2
425 12 12 6 3
3 3 1 3
60 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R060
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 1 2
500 12 12 6 3
3 3 1 3
70 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R070
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1 1 3
800 18 18 9 3
3 3 1 3
80 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R080
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
4 1 1 2
350 12 12 6 3
3 3 1 3
GAC3455TOP
50 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R050
P/N: 25G130R080
80 TOWER
78
8.9 6.8
9.4
OR
101
64
3/16EHS
(399#)
81
50
25 69
P/N: 25G130R040
40 TOWER
38
10.8 7.9
11.2
OR
50
32
3/16EHS
(399#)
P/N: 25G130R050
50 TOWER
48
10.1 7.5
10.0
OR
62
40
3/16EHS
(399#)
46
22
P/N: 25G130R060
60 TOWER
58
9.7 7.2
9.8
OR
75
48
3/16EHS
(399#)
56
28
P/N: 25G130R070
70 TOWER
68
9.2 7.0
9.6
OR
88
56
3/16EHS
(399#)
64
32
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S TA NDA R D DE S I GN - 2 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
35
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
GUY E D T OWE R S - 2 5 G
G
CB1G
CB1G
CB1G
CB1G
CB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J
GAC3455TOP AGK1GGX BGK3GGX
8 1 1 3
900 18 18 9 3
3 3 1 3
TBSAFETY
CPC.5/.75
90 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R090
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G 25AG2 BPC25G GA25GD
3/16EHS BG2142 5/16THH 1/2TBE&J
GAC3455TOP AGK1GGX BGK3GGX
9 1 1 3
1000 18 18 9 3
3 3 1 3
TBSAFETY
CPC.5/.75
100 ROHN 25G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 25G130R100
P/N: 25G130R090
90 TOWER
88
8.6 6.7
9.2
OR
114
72
3/16EHS
(399#)
91
56
28 77
P/N: 25G130R100
100 TOWER
98
8.3 6.5
9.0
OR
127
80
3/16EHS
(399#)
102
63
32 86
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
S TA NDA R D DE S I GN - 2 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
36
3/4x12PP
1
3/4x12PP
1
2011 ROHN PRODUCTS LLC
FDNS
BASE ANCHOR
AB2
FDNS
BASE ANCHOR
AB2
CB1G
CB1G
G
GUY E D T OWE R S - 2 5 G
TOP SECTION
25AG2
TOP SECTION
25AG3
TOP SECTION
25AG4
TOP PLATE HOLE PATTERN IS THE
SAME AS BPL25G.
BEARING PLATE
BPL25G
LONG LEGS PROVIDE EXTRA CLEARANCE
FOR INSTALLATION OF EQUIPMENT.
BOLTS TO TOP OF STANDARD SECTION.
HOLE PATTERN FITS TB3 (2 O.D.) AND TB4
(3 O.D.) THRUST BEARINGS.
TOP PLATE
APL25G
FOR MOUNTING BEACON
OR LIGHTNING ROD.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
9 - 3 1/4
1 - 0
1 - 3
8 - 3/16
1 - 1/4
1 - 3 3/4
37
1.66 O.D.
1.38 I.D.
1.25 N.P.T.
9 - 9
1 - 6
1 - 3
2.25 O.D.
2.08 I.D.
9 - 3 1/2
1 - 0
1 - 4 3/4
2.25 O.D.
2.08 I.D.
8 - 3 1/2
1 - 5 1/4
2.75 O.D.
2.58 I.D.
TOP SECTION
25AG1
TOP SECTION
25AG5
2011 ROHN PRODUCTS LLC
2.00 O.D.
1.87 I.D.
9 - 0
TOP SECTION
25AG
COMES WITH TOP BUSHING INSTALLED,
1.31 I.D.
8 1/4
1 - 4
Set Screw
Set Screw
TOP MOUNT
25TDMKD - NO MAST
25TDM2S3KD - 2 3/8 O.D. MAST
25TDM25S3KD - 2 7/8 O.D. MAST
25TDM3S3KD - 3 1/2 O.D. MAST
25TDM35S3KD - 4 O.D. MAST
MOUNTING TUBE PROVIDED IS 7 LONG.
BEARING/ACCESSORY SHELF
BAS25G
HOLE PATTERN FITS TB3 (2 O.D.) AND
TB4 (3 O.D.) THRUST BEARINGS ON
TOP PLATE. ACCESSORY SHELF DRILLED
FOR MOUNTING MANY POPULAR ROTORS.
LIGHTNING ROD
LRCL
5 COPPER CLAD, MOUNTS TO APL25G.
Set Screw
1-33/4
1-33/4
1-33/4
1- 4
G
GUY E D T OWE R S - 2 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
38
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
2011 ROHN PRODUCTS LLC
PA R T S & ACC E S S OR I E S
PEAK ROOF MOUNT
PR25G*
ADJUSTABLE HINGED FEET CONFORM
TO NEARLY ANY ROOF PITCH. BOLTS
TO ROOF SURFACE.
34 SHORT BASE
SB25G
5 SHORT BASE
SB25G5
FOR EMBEDMENT IN CONCRETE.
HINGED BASE PLATE
BPH25G*
FOR USE WITH 1/2X12BB BASE BOLTS
(ORDERED SEPARATELY).
HINGED TO ALLOW TOWER TO
BE ROTATED UP FROM BASE
DURING INSTALLATION.
HINGED BASE PLATE IS TO BE
USED FOR BRACKETED AND GUYED
APPLICATIONS ONLY.
SINGLE DRIVE-IN BASE
SDB25G*
TO BE DRIVEN DIRECTLY INTO GROUND. TAPERED BASE
25TG*
CAN BE USED WITH A4197L
BASE INSULATOR OR WITH 3/4x12PP,
ORDERED SEPARATELY.
CONCRETE BASE PLATE
FOR SELF-SUPPORTING TOWERS
25GSSB
FOR USE WITH 5/8 x 12 (P/N: 260145G)
BASE BOLTS (ORDERED SEPARATELY)
IN SELF-SUPPORTING
25G TOWER APPLICATIONS.
CONCRETE BASE PLATE
FOR GUYED & BRACKETED TOWERS
BPC25G*
FOR USE WITH 3/4X12PP PIER PIN
EMBEDDED IN CONCRETE.
CONCRETE BASE PLATE IS TO BE
USED FOR BRACKETED AND
GUYED APPLICATIONS ONLY.
PIER PIN
3/4X12PP
FOR USE WITH BPC25G
EMBEDDED IN CONCRETE.
PIER PIN MUST BE ORDERED
SEPARATELY, UNLESS BEING
PURCHASED AS PART OF
A COMPLETE TOWER KIT.
BASE BOLTS
1/2X12BB
FOR USE WITH BPH 25G
(6) REQUIRED, ORDERED SEPARATELY.
34 HINGED SHORT BASE
SBH25G*
FOR EMBEDMENT IN CONCRETE.
BASE BOLT & TEMPLATE
KH8175A
FOR USE WITH 25GSSB
IN SELF-SUPPORTING 25G TOWER
APPLICATIONS. KIT INCLUDES (1)
TEMPLATE & (4) BASE BOLTS.
WALL MOUNT
25GWM
INCLUDES BASE PLATE TO
MOUNT 25G SECTION.
5/8 x 12
1/2 x 12
G
GUY E D T OWE R S - 2 5 G
ACCESSORY SHELF
AS25G
FOR MOUNTING MANY POPULAR
ROTORS. FIELD DRILLING MAY BE
NECESSARY FOR SOME ROTORS.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
39
2011 ROHN PRODUCTS LLC
UNIVERSAL EAVE BRACKET
EB2525G
HINGED CONNECTION ALLOWS TOWER
LEG CLAMPS TO REMAIN PERPENDICULAR
TO GROUND WHILE BOLT DOWN
SUPPORTS ROTATE TO LAY FLAT ALONG
PITCHED ROOF OR EAVE.
TORQUE BAR
TB25D
OPTIONAL, FOR USE WITH GA25GD.
REQUIRES (1) 3/8 SHACKLE
FOR EACH BAR.
TORQUE ARM STABILIZER
ASSEMBLY
TA25
ANTI-TWIST DEVICE LOCATED IN THE
AREA OF ANTENNAS. PROVIDES SIX-WAY
GUYING. BOLTS TO TOWER AT ANY
SECTION JOINT. ATTACHED WITH
JOINT BOLTS. MUST BE INSTALLED AS
SECTIONS ARE JOINED TOGETHER.
GUY BRACKET
GA25GD
MOUNTS TO TOWER AT ANY
HORIZONTAL BRACE.
SIDE ARM MOUNT
UHF25G
FOR UHF & FM ANTENNAS.
SIDE ARM BRACKET
SA253UA
MOUNTING TUBE PROVIDED IS 3 LONG,
2 - 1/4 O.D.
ADJUSTABLE HOUSE BRACKET
HB25AG 0 - 15
HB25BG 0 - 24
HB25CG 0 - 36
HEAVY DUTY UNIVERSAL
HOUSE BRACKET
HBUTVRO
ADJUSTABLE TO POSITION TOWER
18 - 36 FROM WALL.
7/8 - 1 1/8 O.D.
Mounting Pipe
FLAT ROOF MOUNT
FR25G*
BOLTS DIRECTLY TO FLAT ROOF SURFACE.
1
FACE MOUNT
DM25G2 - 2 3/8 O.D. 5 LONG
DBS ANTENNA MOUNT
KY2068A16 - 1.66 O.D.
KY2068A15 - 1.50 O.D.
KY2068A2 - 2.38 O.D.
MOUNTING TUBE PROVIDED IS 3 LONG.
1
Adjustable
2.5 - 3.0
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
SAFETY RING
SR245
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
G
GUY E D T OWE R S - 2 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
40
2011 ROHN PRODUCTS LLC
PA R T S & ACC E S S OR I E S
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SLIDER
WITH CARABINEER
TT-WG-500-W/SMC
WORK PLATFORM
WP25G
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
ERECTION FIXTURE
EF2545 - 2 1/2 SHEAVE WITH
3/8 I.D. GROOVE.
NOTE: ERECTION FIXTURES ARE FOR
LIFTING ONE 10 SECTION AT A TIME AND
ARE NOT INTENDED FOR THE LIFTING OF
PERSONNEL.
SAFETY CABLE SYSTEM
ORDERING INFORMATION
TOWER
HEIGHT
50
100
150
200
PART
NUMBER
TT05025
TT10025
TT15025
TT20025
SAFETY CABLE SLIDER AND
CLIMBING HARNESS MUST
BE ORDERED SEPARATELY.
90 JOINTS
2590MM - BOTH ENDS SWAGED
JOINTS ARE NOT DRILLED WHERE THEY
SLIP FIT TO 25G SECTIONS. CAN BE
FIELD DRILLED OR CUSTOM CONNECTED
TO MEET PARTICULAR NEEDS.
90 JOINTS
2590FF - BOTH ENDS OPEN
JOINTS ARE NOT DRILLED WHERE THEY
SLIP FIT TO 25G SECTIONS. CAN BE
FIELD DRILLED OR CUSTOM CONNECTED
TO MEET PARTICULAR NEEDS.
90 JOINTS
2590FM - ONE END SWAGED,
ONE OPEN
JOINTS ARE NOT DRILLED WHERE THEY
SLIP FIT TO 25G SECTIONS. CAN BE
FIELD DRILLED OR CUSTOM CONNECTED
TO MEET PARTICULAR NEEDS.
ANTI-CLIMB PANELS
25ACL3
THREE ANTI-CLIMB PANELS BOLT
TO STANDARD TOWER SECTION.
ROTOR POST
1.25 O.D.
1.08 I.D.
RP25G CM
Tower
Leg
RP25G
Tower
Leg
THRUST BEARING
TB3 - SUPPORTS UP TO 2 O.D. MAST.
TB4 - SUPPORTS UP TO 3 O.D. MAST.
MOUNTS TO BAS25G, BPL25G
AND 25AG4.
TOWER BUSHING
TB50 - 1-1/4 I.D. X 2 O.D.
TB75 - 1-1/2 I.D. X 2 O.D.
FOR USE ON 25AG TOP SECTION
REV G
ANCHOR GROUNDING
AGK1GGX
REV G
BASE GROUNDING
BGK3GGX
A NC HOR I NF OR MAT I ON
12
3/8
2
3/4
P/N STAMPED HERE
GAC3455TOP
1/2
12
120
1 1/4 P/N STAMPED HERE
GAC5655TOP
2 1/2
11/16
13/16
C
L
of hole to edge
of plate = 1 1/4
C
L
of hole to edge
of plate = 1
4 x 4 x 3/8 angle
5 x 5 x 3/8 angle
81
G
GUY E D T OWE R S - 2 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
41
2011 ROHN PRODUCTS LLC
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp
6 Min.
Attach to leg with
supplied leg clamp
Ground Wire
6 Min.
Ground Rod Clamp
Ground Rod,
3 provided (to be installed
at 120 separation at 20 spacing.
o
S TA NDA R D A NC HOR B L OC K S
All around stirrups
equally spaced 12
O.C. anchored with 90
hooks around a
horizontal bar
Top and bottom
horizontal bars
equally spaced
C
B
A
Ground Line
D
Anchor rod
Block
AB2
AB3
AB4
AB5
AB6
A
4 - 0
6 - 0
6 - 0
8 - 0
8 - 0
Concrete Vol.
(Cu. Yds.)
1.33 Per Block
4.0 Total for 3
1.0 Per Block
3.0 Total for 3
2.0 Per Block
6.0 Total for 3
2.22 Per Block
6.7 Total for 3
2.96 Per Block
8.9 Total for 3
B
1 - 6
1 - 6
1 - 6
2 - 0
2 - 0
C
4 - 0
3 - 0
4 - 0
3 - 0
4 - 0
Horizontal Bars
(Qty. & Size)
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer
(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer
(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer
(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
D
6 - 0
6 - 0
9 - 0
10 - 0
10 - 0
Anchor Dimensions (in.)
Stirrup Size
& Spacing
#3 @ 12 O.C.
#3 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
o
Additional bar at
center-line each
side, when required
Refer to page 43 for anchor rod installation angles.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
2011 ROHN PRODUCTS LLC
42
A NC HOR R OD I NS TA L L AT I ON A NGL E S
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Rod
Angle
48
42
42
42
39
39
39
39
38
38
38
37
37
37
37
37
25G | 90MPH
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Inner
Rod
Angle
48
41
41
41
38
38
39
38
37
37
37
36
36
40
41
43
25G | 110MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC3455TOP
GAC3455TOP
GAC3455TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
42
42
42
Tower
Height
40
50
60
70
80
90
100
Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Rod
Angle
50
41
41
40
38
38
38
25G | 130MPH
120
o
Tower Plan
Ground Line
Rod Angle
(in degrees)
Anchor Rod Angle
o
G
GUY E D T OWE R S - 2 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
43
2011 ROHN PRODUCTS LLC
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 2 5 G
2011 ROHN PRODUCTS LLC
44
S TA NDA R D B A S E P I E R S
Base
CB1G*
CB2G
A
2 - 6
3 - 0
Vertical Bars
(No. & Size)
(8) #7
(10) #7
Concrete Vol.
(Cu. Yds.)
Round Pier
1.0
1.2
B
4 - 0
4 - 0
Alternate
Square
Pier
PLAN VIEW
A
No. 4 Circular ties, 3 O.C.
with 24 laps
Vertical bars equally spaced
(2) No. 4 Circular ties, 2-1/2 O.C.
with 2 cover with 24 laps
4 Projection
6
No. 4 Circular ties, 3 Max. O.C.
with 24 laps
Vertical bars equally spaced
B
ELEVATION VIEW
Grade
C
L
C
L
Pier Pin
A
* Square pier option must be used for CB1G.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
45
2011 ROHN PRODUCTS LLC
NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D 4 5 G GUY E D T OWE R
46
2011 ROHN PRODUCTS LLC
The first. The original.
ROHN 45G
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 65 for ordering information.
REV. G
includes
REV. F&
GENERAL USE
The 45G is a true multi-use structure that provides
excellent strength for applications up to 300,
It is ofered with heavy steel round legs to satisfy
a variety of needs under varied conditions.
FEATURES
Completely hot-dip galvanized after fabrication
Built on a 16 3/4 equilateral triangle design
High strength tubular legs joined by Zig-Zag

cross members
Each section contains all required nuts and bolts
shipped with section
Continuous solid round steel bracing
45G
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all
engineering and warranty data supplied by ROHN. Materials used by others are
not the same quality and have not been tested or engineered by ROHN. Mixing
ROHN tower sections with non-ROHN products may cause tower failure or injury.
CAUTION
1 1/4 O.D.
(14 GA.)
9 6
1 6
STANDARD SECTION
45G - 10 Section
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D 4 5 G GUY E D T OWE R
S E C T I ONS
47
2.38 O.D.
2.07 I.D.
14 1/2
9 11/16
7/16 O.D.
Solid Bracing
STANDARD TOP SECTION
45AG2
Additional 45G top sections
are shown on page 63.
7/16 O.D.
Solid Bracing
2011 ROHN PRODUCTS LLC
16 3/4
PARTS & ACCESSORIES PAGES 63-65
GROUNDING INFORMATION PAGE 66
FOUNDATION INFORMATION PAGES 66-69
QUICK REFERENCE
2 0
Optional double braced sections
are available upon request.
Optional Waveguide
Brackets (KY2041A)
* Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.
CONCRETE BASE PLATE
BPC45G*
FOR USE WITH 3/4X12PP PIER PIN
EMBEDDED IN CONCRETE.
Additional base sections are
available, please see page 64.
1 1/4 O.D.
(14 GA.)
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
EPA (SQ. FT.), Revision F
P/N 45G90R040

45
31
40
3/16 EHS
(399#)
23.1
22.6
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
31.4
B UY E R S GUI DE
S TA NDA R D DE S I GNS - 4 5 G
9 0 MP H R E V. G [ 3 - S E C ON D G U S T ]
7 0 MP H R E V. F [ FA S T E S T MI L E ]
48
P/N 45G90R040

Tower Model
Windspeed (Rev. G) ROHN Tower
Tower Height (ft.)
EPA= Effective Projected Area
2011 ROHN PRODUCTS LLC
Guy Initial Tension
This document is to serve as a guide for sizing and purchasing the 45G tower. Tower and foundation installations should
be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites
located on unusual terrain.
3. Designs assume two 1/2 diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60 Fahrenheit.
6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 66-69.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
Design Criteria
49
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J
TBSAFETY AGK1GGX BGK3GGX CPC.5/.75
11 1 1 3
700 12 12 9
3 3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
AB2 CB1G
GAC3455TOP
BG2144
6
1/4EHS
475
3/8THH
6
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
50
2011 ROHN PRODUCTS LLC
100 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R100
P/N: 45G90R100
100 TOWER
85
24.3 18.9
17.0
OR
117
80
1/4EHS
(665#)
92
45
3/16EHS
(399#)
120 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R120
P/N: 45G90R120
120 TOWER
105
23.0 18.2
16.0
OR
142
96
3/16EHS
(399#)
116
65
35 102
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
8 1 1 2
625 12 12 6 3
3 3 1 3
P/N: 45G90R090
90 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R090
90 TOWER
85
25.0 19.4
17.6
OR
111
72
3/16EHS
(399#)
85
45
3/4x12PP
1
FDNS
BASE ANCHOR
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
10 1 1 3
1100 18 18 9 3
3 3 1 3
110 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R110
P/N: 45G90R110
110 TOWER
105
23.6 18.6
16.4
OR
137
88
3/16EHS
(399#)
109
65
35 95
3/4x12PP
1
FDNS
BASE ANCHOR
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
AGK1GGX BGK3GGX CPC.5/.75
12 1 1 3
1325 18 18 9 3
3 3 1 3
130 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R130
P/N: 45G90R130
130 TOWER
125
22.5 17.9
15.6
OR
163
104
3/16EHS
(399#)
134
85
45 113
3/4x12PP
1
FDNS
BASE ANCHOR
AB2
AB2
AB2 CB1G
CB1G
CB1G
GAC3455TOP
GAC3455TOP
GAC3455TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J
TBSAFETY AGK1GGX BGK3GGX CPC.5/.75
9 1 1 2
300 6 6 6
3
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
AB2 CB1G
GAC3455TOP
BG2144
6
1/4EHS
375
3/8THH
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J
TBSAFETY AGK1GGX BGK3GGXCPC.5/.75
16 1 1 4
1575 18 18 12
3 3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
AB2 CB1G
GAC3455TOP
BG2144
6
1/4EHS
700
3/8THH
6
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
51
2011 ROHN PRODUCTS LLC
P/N: 45G90R140
140 TOWER
125
22.0 17.6
15.2
OR
168
112
1/4EHS
(665#)
141
85
45 121
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
13 1 1 3
850 550 12 6 12
3 3 1 3
140 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R140
3/4x12PP
1
FDNS
BASE ANCHOR
3/8THH
6
1/2TBE&J
9
3/16EHS
(399#)
P/N: 45G90R160
160 TOWER
145
21.2 17.1
14.4
OR
193
128
1/4EHS
(665#) 166
105
35 133
65
144
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
15 1 1 4
1425 625 18 6 18
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 12
160 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R160
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
P/N: 45G90R180
180 TOWER
165
20.5 16.7
14.0
OR
219
144
1/4EHS
(665#) 191
125
45 151
85
167
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
17 1 1 4
1625 700 18 6 18
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 12
180 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R180
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
P/N: 45G90R150
150 TOWER
145
21.6 17.4
14.8
OR
188
120
159
105
35 125
65
136
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
14 1 1 4
1950 24 24 12 3
3 3 1 3
150 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R150
3/4x12PP
1
FDNS
BASE ANCHOR
P/N: 45G90R170
170 TOWER
165
20.8 16.9
14.2
OR
214
136
185
125
45 143
85
160
3/16EHS
(399#)
170 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R170
1/4EHS
(665#)
AB2
AB2
AB2
AB2
CB1G
CB1G
CB1G
CB1G
TBSAFETY
3
TBSAFETY
3
TBSAFETY
3
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
52
2011 ROHN PRODUCTS LLC
P/N: 45G90R200
200 TOWER
185
19.8 16.3
11.4
OR
245
160
1/4EHS
(665#) 216
145
35
105
191
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
20 1 1
2375 800 24 6 24
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 15
200 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R200
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
5
173
164
65
P/N: 45G90R220
220 TOWER
205
19.3 16.0
11.0
OR
270
176
1/4EHS
(665#) 241
165
45
125
216
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
22 1 1
2100 875 24 6 24
6 6 2 3
3/4x12PP
1
6 15
220 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R220
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
5
85
87
113
3/16EHS
(399#)
6
TBSAFETY
75
P/N: 45G90R190
190 TOWER
185
20.2 16.5
13.6
OR
239
152
210
145
35
105
185
3/16EHS
(399#)
165
156
65
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
18 1 1 5
3050 30 30 15 3
3 3 1 3
190 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R190
3/4x12PP
1
FDNS
BASE ANCHOR
P/N: 45G90R210
210 TOWER
205
19.5 16.1
11.2
OR
265
168
235
165
45
85
87
113
3/16EHS
(399#)
209
125
75
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G APL45G BPC45G GA45GD
3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
21 1 1 5
2900 30 30 15 6
6 6 2 3
210 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R210
3/4x12PP
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G APL45G BPC45G GA45GD
3/16EHS BG2142 5/16THH TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
23 1 1 6
3675 36 36 6
6 6 2 3
230 ROHN 45G
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45G90R230
3/4x12PP
1
P/N: 45G90R230
230 TOWER
225
19.1 15.8
10.6
OR
291
184
261
185
35
105
65
65
85
3/16EHS
(399#)
234
212
145
55
1/2TBE&J
18
AB2
AB2
BASE
INNER
ANCHOR
OUTER
ANCHOR
AB2 AB2
BASE
INNER
ANCHOR
OUTER
ANCHOR
AB2 AB1
BASE
INNER
ANCHOR
OUTER
ANCHOR
AB2 AB1
GAC3455TOP
CB1G
CB1G
CB2G
CB2G
CB2G
TBSAFETY
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
26 1 1
3200 1025 30 6 30
6 2 3
3/4x12PP
1
6 18
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
6
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB2 AB2
GAC3455TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
25 1 1
3125 1025 30 6 30
6 2 3
3/4x12PP
1
6 18
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
6
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB2G
OUTER
ANCHOR
AB2 AB1
GAC3455TOP
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
53
2011 ROHN PRODUCTS LLC
240 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R240
P/N: 45G90R240
240 TOWER
225
18.9 15.7
10.4
OR
296
192
1/4EHS
(665#) 267
185
35
105
65
65
85
3/16EHS
(399#)
241
219
145
55
P/N: 45G90R260
260 TOWER
245
18.4 15.5
10.2
OR
321
208
1/4EHS
(665#) 292
205
45
125
260 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R260
85
87
113
3/16EHS
(399#)
265
243
165
75
P/N: 45G90R280
280 TOWER
265
18.0 15.2
9.8
OR
347
224
1/4EHS
(665#) 317
225
65
145
280 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R280
105
111
138
3/16EHS
(399#)
291
267
185
90
35
97
250 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R250
P/N: 45G90R250
250 TOWER
245
18.6 15.6
10.4
OR
316
200
1/4EHS
(665#) 286
205
45
125
85
87
113
3/16EHS
(399#)
259
236
165
75
P/N: 45G90R270
270 TOWER
265
18.2 15.4
10.0
OR
342
216
1/4EHS
(665#) 312
225
65
145
270 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R270
105
111
138
3/16EHS
(399#)
284
260
185
90
35
97
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
24 1 1
2800 950 30 6 30
6 2 3
3/4x12PP
1
6 18
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
6
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB2G
OUTER
ANCHOR
AB2 AB1
GAC3455TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
27 1 1
3825 1100 36 6 36
6 2 3
3/4x12PP
1
6 21
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
7
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB2 AB2
GAC3455TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
28 1 1
3900 1125 36 6 36
6 2 3
3/4x12PP
1
6 21
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
7
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB2 AB2
GAC3455TOP
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
54
2011 ROHN PRODUCTS LLC
P/N: 45G90R300
300 TOWER
285
17.6 15.0
9.6
OR
373
240
1/4EHS
(665#) 343
245
85
165
300 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R300
125
135
163
3/16EHS
(399#)
316
291
205
105
45
114
P/N: 45G90R290
290 TOWER
285
17.8 15.1
9.6
OR
367
232
1/4EHS
(665#) 337
245
85
165
290 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G90R290
125
135
163
3/16EHS
(399#)
310
285
205
105
45
114
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
29 1 1
4275 1175 36 6 36
6 2 3
3/4x12PP
1
6 21
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
7
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB2 AB2
GAC3455TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G
AGK1GGX BGK3GGX CPC.5/.75
30 1 1
4350 1200 36 6 36
6 2 3
3/4x12PP
1
6 21
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
GA45GD
7
6
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB2 AB2
GAC3455TOP
S TA NDA R D DE S I GN - 4 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
55
2011 ROHN PRODUCTS LLC
P/N: 45G110R040
40 TOWER
31
21.3 15.5
21.6
OR
45
32
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
1/4EHS BG2144
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1 1
150 6 3
3 3 1 3
40 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R040
3/4x12PP
1
FDNS
BASE ANCHOR
3/8THH
6
TBSAFETY
3
1/2TBE&J
P/N: 45G110R060
60 TOWER
51
18.9 14.1
19.0
OR
70
48
1/4EHS
(665#) 54
25
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 1 2
175 225 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
60 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R060
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
P/N: 45G110R080
80 TOWER
71
17.4 13.4
17.4
OR
96
64
1/4EHS
(665#) 73
35
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1 1 2
250 325 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
80 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R080
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
P/N: 45G110R050
50 TOWER
41
19.9 14.7
20.2
OR
57
40
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
1/4EHS BG2144
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1 1 1
200 6 3
3 3 1 3
50 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R050
3/4x12PP
1
FDNS
BASE ANCHOR
3/8THH
6
TBSAFETY
3
1/2TBE&J
P/N: 45G110R070
70 TOWER
61
18.0 13.7
18.2
OR
83
56
1/4EHS
(665#) 63
29
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 1 2
225 275 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
70 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R070
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
8 1 1 2
275 350 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
CB1G AB2
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
56
2011 ROHN PRODUCTS LLC
P/N: 45G110R100
100 TOWER
91
16.3 12.7
16.2
OR
121
80
1/4EHS
(665#) 101
61
3/16EHS
(399#)
100 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R100
31
86
P/N: 45G110R120
120 TOWER
111
15.4 12.2
15.2
OR
147
96
1/4EHS
(665#) 122
75
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
11 1 1 3
725 475 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 9
3
120 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R120
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH
TBSAFETY
1/2TBE&J
35
102
P/N: 45G110R110
110 TOWER
101
15.8 12.5
15.6
OR
134
88
1/4EHS
(665#) 111
67
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
10 1 1 3
675 450 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 9
110 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R110
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
34
94
P/N: 45G110R130
130 TOWER
121
15.1 12.0
14.8
OR
160
104
1/4EHS
(665#) 130
78
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
12 1 1 3
775 525 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 9
3
130 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R130
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH
TBSAFETY
1/2TBE&J
35
110
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
9 1 1 3
600 400 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 9
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
P/N: 45G110R090
90 TOWER
81
16.8 13.0
16.8
OR
108
72
82
39
3/16EHS
(399#)
90 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R090
1/4EHS
(665#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
57
2011 ROHN PRODUCTS LLC
P/N: 45G110R150
150 TOWER
141
14.5 11.7
14.0
OR
185
120
1/4EHS
(665#) 160
106
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
14 1 1 4
1375 600 18 6 18
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 12
3
150 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R150
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH
TBSAFETY
1/2TBE&J
72
140
125 35
P/N: 45G110R160
160 TOWER
151
14.2 11.5
13.8
OR
198
128
1/4EHS
(665#) 171
113
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
15 1 1 4
1450 650 18 6 18
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 12
3
160 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R160
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH
TBSAFETY
1/2TBE&J
76
149
134 38
P/N: 45G110R170
170 TOWER
161
14.0 11.4
13.6
OR
211
136
1/4EHS
(605#)
187
128
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
16 1 1 5
2050 675 24 6 24
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 15
170 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R170
3/16EHS 1/4EHS BG2142BG2144 5/16THH 3/8THH 5/8TBE&J
64
150
32
96
166
TBSAFETY
3
140
P/N: 45G110R180
180 TOWER
172
13.8 11.2
13.2
OR
224
144
5/16EHS
(1,120#)
197
135
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL2* BPC45G GA45GD
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
17 1 1 5
2175 725 24 6 24
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 15
180 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R180
3/16EHS 142265 BG2142BG2146 5/16THH7/16THH 5/8TBE&J
66
158
33
99
175
TBSAFETY
3
148
CB1G AB2
CB2G AB2
CB2G AB3
CB2G AB3
P/N: 45G110R140
140 TOWER
131
14.8 11.8
14.4
OR
172
112
1/4EHS
(665#) 149
98
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
13 1 1 4
1275 550 18 6 18
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 12
3
140 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G110R140
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH
TBSAFETY
1/2TBE&J
65
129
116 32
CB1G AB2
APL45G
1
* 45GL2 Lug section required for 5/16 guy
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
58
2011 ROHN PRODUCTS LLC
P/N: 45G110R200
200 TOWER
192
13.4 11.0
10.6
OR
250
160
5/16EHS
(1,120#)
223
155
3/16EHS
(399#)
200 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R200
75
177
35
115
197
164
P/N: 45G110R220
220 TOWER
212
13.0 10.8
10.2
OR
276
176
5/16EHS
(1,120#)
175
35
139
105
69
91
3/16EHS
(399#)
60
69
205
224
248
1/4EHS
(665#)
210 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R210
P/N: 45G110R210
210 TOWER
202
13.2 10.9
10.4
OR
263
168
5/16EHS
(1,120#)
167
33
133
99
64
85
3/16EHS
(399#)
55
65
195
214
237
220 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R220
P/N: 45G110R190
190 TOWER
182
13.6 11.1
13.0
OR
237
152
5/16EHS
(1,120#)
210
145
3/16EHS
(399#)
190 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R190
73
169
36
109
187
156
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL2* BPC45G GA45GD
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
18 1 1 5
2300 725 24 6 24
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 15
3/16EHS 142265 BG2142BG2146 5/16THH7/16THH 5/8TBE&J
TBSAFETY
3
CB2G AB3
APL45G
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL2* BPC45G GA45GD
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
19 1 1 5
2425 800 24 6 24
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 15
3/16EHS 142265 BG2142BG2146 5/16THH7/16THH 5/8TBE&J
TBSAFETY
3
CB2G AB3
APL45G
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G GA45GD
GAC3455TOP BGK3GGX CPC.5/.75
20 1 1 6
3 3 3
CPC1/1.25
3
3/16EHS
2550
7/16THH
6
142265
850
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
TBSAFETY
6
AGK1GGX
2
GAC5655TOP
3
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB3 AB2
45GL2*
1
3/4x12PP
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G GA45GD
GAC3455TOP BGK3GGX CPC.5/.75
21 1 1 6
3 3 3
CPC1/1.25
3
3/16EHS
1875
1/4EHS
800
142265
900
5/16THH
24
BG2142
24
3/8THH
6
BG2144
6
7/16THH
6
AGK1GGX
2
GAC5655TOP
3
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB3 AB2
45GL2*
1
5/8TBE&J
12
BG2146
6
1/2TBE&J
6
TBSAFETY
6
3/4X12PP
1
* 45GL2 Lug section required for 5/16 guy
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G GA45GD
GAC3455TOP BGK3GGX CPC.5/.75
23 1 1 7
3 3 3
CPC1/1.25
3
3/16EHS
2525
BG2146
6
1/4EHS
875
5/16THH
30
142265
975
3/8THH
6
BG2142
30
7/16THH
6
BG2144
6
AGK1GGX
2 3
1/2TBE&J
9
5/8TBE&J
12
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB3 AB2
3/4x12PP
1
45GL2*
1
GAC5655TOP
S TA NDA R D DE S I GN - 4 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
59
2011 ROHN PRODUCTS LLC
240 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R240
P/N: 45G110R240
240 TOWER
232
12.7 10.6
10.0
OR
301
192
5/16EHS
(1,120#)
195
35
159
125
87
3/16EHS
(399#)
80
65
229
249
274
1/4EHS
(665#)
103
124
95
P/N: 45G110R230
230 TOWER
222
12.8 10.7
10.0
OR
288
184
5/16EHS
(1,120#)
185
33
155
125
87
3/16EHS
(399#)
80
65
222
241
261
1/4EHS
(665#)
103
124
95
230 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G110R230
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G BPC45G APL45G GA45GD
GAC3455TOP BGK3GGX CPC.5/.75
22 1 1 7
3 3 3
CPC1/1.25
3
3/16EHS
2475
BG2146
6
1/4EHS
850
5/16THH
30
142265
925
3/8THH
6
BG2142
30
7/16THH
6
BG2144
6
AGK1GGX
2 3
1/2TBE&J
9
5/8TBE&J
12
TBSAFETY
6
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB3 AB2
3/4x12PP
1
45GL2*
1
GAC5655TOP
* 45GL2 Lug section required for 5/16 guy
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
60
2011 ROHN PRODUCTS LLC
P/N: 45G130R040
40 TOWER
35
15.3 11.1
13.0
OR
47
32
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
1/4EHS BG2144
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1 1
150 6
3 3 1 3
40 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R040
3/4x12PP
1
FDNS
BASE ANCHOR
3/8THH
6 3
TBSAFETY
3
1/2TBE&J
P/N: 45G130R060
60 TOWER
55
13.6 10.2
11.6
OR
73
48
1/4EHS
(665#)
25
54
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 1 2
175 250 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH
6
1/2TBE&J
TBSAFETY
3
60 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R060
P/N: 45G130R080
80 TOWER
75
12.5 9.6
10.6
OR
99
64
1/4EHS
(665#)
35
73
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1 1 2
250 325 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
80 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R080
P/N: 45G130R050
50 TOWER
45
14.3 10.6
12.0
OR
60
40
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
1/4EHS BG2144
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1 1 1
200 6
3 3 1 3
50 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R050
3/4x12PP
1
FDNS
BASE ANCHOR
3/8THH
6 3
TBSAFETY
3
1/2TBE&J
P/N: 45G130R070
70 TOWER
65
13.0 9.9
11.0
OR
86
56
1/4EHS
(665#)
29
63
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 1 2
225 275 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
70 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R070
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
61
2011 ROHN PRODUCTS LLC
P/N: 45G130R100
100 TOWER
95
11.7 9.2
9.6
OR
124
80
1/4EHS
(665#)
61
101
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
9 1 1 3
600 400 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 9
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
3
TBSAFETY
100 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R100
31
86
P/N: 45G130R120
120 TOWER
115
11.1 8.8
8.6
OR
150
96
5/16EHS
(1,120#)
75
122
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL5* BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
11 1 1 3
725 500 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
3/16EHS 142265 BG2142 BG2146 5/16THH7/16THH1/2TBE&J
3
5/8TBE&J
120 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G130R120
35
102
TBSAFETY
3
P/N: 45G130R090
90 TOWER
85
12.1 9.4
10.0
OR
111
72
1/4EHS
(665#)
39
82
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
8 1 1 2
275 375 6 6 6
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 6
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
TBSAFETY
3
90 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R090
P/N: 45G130R110
110 TOWER
105
11.4 9.0
9.0
OR
137
88
1/4EHS
(665#)
67
111
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45AG2 BPC45G GA45GD
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
10 1 1 3
675 450 12 6 12
3 3 1 3
3/4x12PP
1
FDNS
BASE ANCHOR
6 9
3/16EHS1/4EHS BG2142 BG2144 5/16THH 3/8THH 1/2TBE&J
3
TBSAFETY
110 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R110
34
94
P/N: 45G130R130
130 TOWER
125
10.9 8.6
8.2
OR
163
104
5/16EHS
(1,120#)
78
130 3/16EHS
(399#)
35
110
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL5* BPC45G GA45GD
GAC5655TOP BGK3GGX CPC1/1.25
12 1 1 3
3 3 3
3/4x12PP
1
FDNS
BASE ANCHOR
130 ROHN 45G
All parts shown in
table are included
when ordering
Part No: 45G130R130
3/16EHS
350
5/16THH
6
1/4EHS
425
3/8THH
6
142265
525
7/16THH
6
BG2142
6
BG2144
6
5/8TBE&J
9
BG2146
6
TBSAFETY
3
AGK1GGX
1
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
CB2G AB3
APL45G
1
APL45G
1
* 45GL5 Lug section required for 5/16 guy
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
S TA NDA R D DE S I GN - 4 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
62
2011 ROHN PRODUCTS LLC
140 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R140
P/N: 45G130R140
140 TOWER
135
10.6 8.5
7.8
OR
175
112
5/16EHS
(1,120#)
149
98
32 116
65
129
3/16EHS
(399#)
1/4EHS
(665#)
P/N: 45G130R140
140 TOWER
135
10.6 8.5
7.8
OR
175
112
149
98
32 116
65
129
150 ROHN 45G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45G130R150
P/N: 45G130R150
150 TOWER
145
10.4 8.4
7.4
OR
188
120
5/16EHS
(1,120#)
160
106
35 125
72
140
3/16EHS
(399#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL5* BPC45G GA45GD
GAC5655TOP BGK3GGX CPC1/1.25
13 1 1 4
3 3 3
3/4x12PP
1
FDNS
BASE ANCHOR
3/16EHS
800
5/16THH
12
1/4EHS
475
3/8THH
6
142265
575
7/16THH
6
BG2142
12
BG2144
6
5/8TBE&J
12
BG2146
6
TBSAFETY
3
AGK1GGX
1
CB2G AB3
APL45G
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45G 45GL5* BPC45G GA45GD
GAC5655TOP BGK3GGX CPC1/1.25
14 1 1 4
3 3 3
3/4x12PP
1
FDNS
BASE ANCHOR
3/16EHS
850
5/16THH
12
1/4EHS
525
3/8THH
6
142265
600
7/16THH
6
BG2142
12
BG2144
6
5/8TBE&J
12
BG2146
6
TBSAFETY
3
AGK1GGX
1
CB2G AB3
APL45G
1
* 45GL5 Lug section required for 5/16 guy
G
GUY E D T OWE R S - 4 5 G
TOP SECTION
45AG2
TOP SECTION
45AG3
TOP SECTION
45AG4
TOP PLATE HOLE PATTERN IS THE SAME
AS BPL45G.
BEARING PLATE
BPL45G
CONVERTS STANDARD SECTION TO A
TOP SECTION. HOLE PATTERN FITS
TB3 (2 O.D.) AND TB4 (3 O.D.)
THRUST BEARINGS.
TOP PLATE
APL45G
FOR MOUNTING BEACON
OR LIGHTNING ROD.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
9 - 0
7 - 8
63
1.66 O.D.
1.38 I.D.
1.25 N.P.T. 9 - 6
2.38 O.D.
2.07 I.D.
9 - 0
2.25 O.D.
2.08 I.D.
8 - 1
1 - 1
2.75 O.D.
2.58 I.D.
TOP SECTION
45AG1
TOP SECTION
45AG5
2011 ROHN PRODUCTS LLC
ACCESSORY SHELF
AS455G
FOR MOUNTING MANY POPULAR
ROTORS. FIELD DRILLING MAY BE
NECESSARY FOR SOME ROTORS.
1 - 0
2 - 0
8
1 - 0
2 - 0
2 - 0
1 - 6
1 - 8
9 - 0
2.00 O.D.
1.87 I.D.
TOP SECTION
45AG
1 - 0
LIGHTNING ROD
LRCL
5 COPPER CLAD
MOUNTS TO APL45G.
Set Screw
Set Screw
Set Screw
TOP MOUNT
45TDMKD - NO MAST
45TDM2S3KD - 2 3/8 O.D. MAST
45TDM25S3KD - 2 7/8 O.D. MAST
45TDM3S3KD - 3 1/2 O.D. MAST
45TDM35S3KD - 4 O.D. MAST
45TDM4S3KD - 4 1/2 O.D. MAST
MOUNTING TUBE PROVIDED IS 7 LONG.
1-33/4
2 - 0
G
GUY E D T OWE R S - 4 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
64
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
2011 ROHN PRODUCTS LLC
5 SHORT BASE
SB45G
FOR EMBEDMENT IN CONCRETE.
FLAT ROOF MOUNT
FR45G*
BOLTS DIRECTLY TO FLAT ROOF SURFACE.
TAPERED BASE
45TG*
CAN BE USED WITH A4197L
BASE INSULATOR OR WITH
3/4X12PP, ORDERED SEPARATELY.
CONCRETE BASE PLATE
BPC45G*
FOR USE WITH 3/4X12PP PIER PIN
EMBEDDED IN CONCRETE.
CONCRETE BASE PLATE IS TO BE
USED FOR BRACKETED AND
GUYED APPLICATIONS ONLY.
PIER PIN
3/4X12PP
FOR USE WITH BPC45G
EMBEDDED IN CONCRETE.
PIER PIN MUST BE ORDERED
SEPARATELY, UNLESS BEING
PURCHASED AS PART OF
A COMPLETE TOWER KIT.
BASE BOLT
5/8X12BB
FOR USE WITH BPH45G
(6) REQUIRED, ORDERED SEPARATELY.
SIDE ARM BRACKET
SA253UA
MOUNTING TUBE PROVIDED IS 3 LONG,
2 - 1/4 O.D.
FACE MOUNT
DM45G2 - 2 3/8 O.D. 5 LONG
DM454 - 4 1/2 O.D. 5 LONG
HEAVY DUTY UNIVERSAL
HOUSE BRACKET
HBUTVRO
ADJUSTABLE TO POSITION TOWER
18 - 36 FROM WALL.
HINGED BASE PLATE
BPH45G*
FOR USE WITH 5/8X12BB BASE BOLTS
(ORDERED SEPARATELY).
HINGED TO ALLOW TOWER TO
BE ROTATED UP FROM BASE
DURING INSTALLATION.
HINGED BASE PLATE IS TO BE
USED FOR BRACKETED AND GUYED
APPLICATIONS ONLY.
5/8 x 12
Adjustable
2.5 - 3.0
TORQUE ARM STABILIZER
ASSEMBLY
TA45
ANTI-TWIST DEVICE LOCATED IN THE
AREA OF ANTENNAS. PROVIDES SIX-WAY
GUYING. BOLTS TO TOWER AT ANY
SECTION JOINT. ATTACHED WITH
JOINT BOLTS. MUST BE INSTALLED AS
SECTIONS ARE JOINED TOGETHER.
DISH MOUNT
VY4311A2 - 2 3/8 O.D.
VY4311A - 4 1/2 O.D.
MAST TUBE PROVIDED IS 5 LONG.
G
GUY E D T OWE R S - 4 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
65
2011 ROHN PRODUCTS LLC
SAFETY RING
SR245
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
WORK PLATFORM
WP45G
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
ERECTION FIXTURE
EF2545 - 2 1/2 SHEAVE WITH
3/8 I.D. GROOVE.
NOTE: ERECTION FIXTURES ARE FOR
LIFTING ONE 10 SECTION AT A TIME AND
ARE NOT INTENDED FOR THE LIFTING OF
PERSONNEL.
WARNING WARNING WARNING THISITEMISNOT INTENDEDFORTHE LIFTINGOFPERSONNEL Seesafetyprecautionliterature
THRUST
BEARING
TB3 - SUPPORTS UP TO 2 O.D. MAST.
TB4 - SUPPORTS UP TO 3 O.D. MAST.
MOUNTS TO BPL45G AND 45AG4.
TOWER
BUSHING
TB50 - 1-1/4 I.D. X 2 O.D.
TB75 - 1-1/2 I.D. X 2 O.D.
FOR USE ON 45AG TOP SECTION
GUY BRACKET
GA45GD
MOUNTS TO TOWER AT ANY
HORIZONTAL BRACE.
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SYSTEM
ORDERING INFORMATION
TOWER
HEIGHT
50
100
150
200
250
300
350
PART
NUMBER
TT0504555
TT1004555
TT1504555
TT2004555
TT2504555
TT3004555
TT3504555
SAFETY CABLE
SLIDER WITH CARABINEER
TT-WG-500-W/SMC
ANTI-CLIMB PANELS
VW913A
THREE ANTI-CLIMB PANELS BOLT
TO STANDARD TOWER SECTION.
SAFETY CABLE SLIDER AND
CLIMBING HARNESS MUST
BE ORDERED SEPARATELY.
TORQUE BAR
TB45D
OPTIONAL, FOR USE WITH GA45GD.
REQUIRES (1) 3/8 SHACKLE
FOR EACH BAR.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
66
2011 ROHN PRODUCTS LLC
REV G
ANCHOR GROUNDING
AGK1GGX
REV G
BASE GROUNDING
BGK3GGX
A NC HOR I NF OR MAT I ON
12
3/8
2
3/4 P/N STAMPED HERE
GAC3455TOP
1/2
12
120
1 1/4 P/N STAMPED HERE
GAC5655TOP
2 1/2
11/16
13/16
C
L
of hole to edge
of plate = 1 1/4
C
L
of hole to edge
of plate = 1
4 x 4 x 3/8 angle
5 x 5 x 3/8 angle
81
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp
6 Min.
Attach to leg with
supplied leg clamp
Ground Wire
6 Min.
Ground Rod Clamp
Ground Rod,
3 provided (to be installed
at 120 separation at 20 spacing.
o
All around stirrups
equally spaced 12
O.C. anchored with 90
hooks around a
horizontal bar
Top and bottom
horizontal bars
equally spaced
C
B
A
Ground Line
D
Anchor rod
o
Additional bar at
center-line each
side, when required
G
GUY E D T OWE R S - 4 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
67
2011 ROHN PRODUCTS LLC
S TA NDA R D A NC HOR B L OC K S
Block
AB2
AB3
AB4
AB5
AB6
A
4 - 0
6 - 0
6 - 0
8 - 0
8 - 0
Concrete Vol.
(Cu. Yds.)
1.33 Per Block
4.0 Total for 3
1.0 Per Block
3.0 Total for 3
2.0 Per Block
6.0 Total for 3
2.22 Per Block
6.7 Total for 3
2.96 Per Block
8.9 Total for 3
B
1 - 6
1 - 6
1 - 6
2 - 0
2 - 0
C
4 - 0
3 - 0
4 - 0
3 - 0
4 - 0
Horizontal Bars
(Qty. & Size)
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer
(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer
(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer
(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
D
6 - 0
6 - 0
9 - 0
10 - 0
10 - 0
Anchor Dimensions (in.)
Stirrup Size
& Spacing
#3 @ 12 O.C.
#3 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
Refer to page 68 for anchor rod installation angles.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 G
68
2011 ROHN PRODUCTS LLC
A NC HOR R OD I NS TA L L AT I ON A NGL E S
120
o
Ground Line
Rod Angle
(in degrees)
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Rod
Angle
48
48
40
40
40
40
38
38
38
38
37
37
45G | 130MPH
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Inner
Rod
Angle
45
46
43
43
41
42
42
40
39
40
39
38
37
38
38
36
36
40
40
42
42
40
40
38
38
38
38
45G | 90MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
44
44
42
41
43
42
43
43
44
43
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Inner
Rod
Angle
45
46
41
41
41
41
39
39
39
38
38
38
38
37
37
37
37
41
41
38
39
45G | 110MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
42
42
43
43
Tower Plan Anchor Rod Angle
G
GUY E D T OWE R S - 4 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
69
2011 ROHN PRODUCTS LLC
Base
CB1G*
CB2G
CB3G
A
2 - 6
3 - 0
3 - 6
Vertical Bars
(No. & Size)
(8) #7
(10) #7
(12) #7
Concrete Vol.
(Cu. Yds.)
Round Pier
1.0
1.2
1.6
B
4 - 0
4 - 0
4 - 0
S TA NDA R D B A S E P I E R S
Alternate
Square
Pier
PLAN VIEW
A
No. 4 Circular ties, 3 O.C.
with 24 laps
Vertical bars equally spaced
(2) No. 4 Circular ties, 2-1/2 O.C.
with 2 cover with 24 laps
4 Projection
6
No. 4 Circular ties, 3 Max. O.C.
with 24 laps
Vertical bars equally spaced
B
ELEVATION VIEW
Grade
C
L
C
L
Pier Pin
A
* Square pier option must be used for CB1G.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D 4 5 GS R GUY E D T OWE R
70
2011 ROHN PRODUCTS LLC
The first. The original.
ROHN 45GSR
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 92 for ordering information.
GENERAL USE
The 45GSR maintains the utility of the 45G and
adds the strength of solid round steel legs. The
45GSR has a strong 4 bolt fange connection,
giving connection joints superior strength over
typical 1 bolt fange connection systems. The
45GSR is available in heights up to 340.
FEATURES
Completely hot-dip galvanized after fabrication
Built on a 16 3/4 equilateral triangle design
Heavy solid steel round legs joined by Zig-Zag

cross members
Each section contains all required nuts and bolts
shipped with section
Continuous solid round steel bracing
45GSR
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all
engineering and warranty data supplied by ROHN. Materials used by others are
not the same quality and have not been tested or engineered by ROHN. Mixing
ROHN tower sections with non-ROHN products may cause tower failure or injury.
CAUTION
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D 4 5 GS R GUY E D T OWE R
S E C T I ONS
71
2011 ROHN PRODUCTS LLC
PARTS & ACCESSORIES PAGE 92
GROUNDING INFORMATION PAGE 93
FOUNDATION INFORMATION PAGES 93-97
QUICK REFERENCE
4.3 45GSR SHORT BASE
45GSRSB
TO BE EMBEDDED IN CONCRETE.
STANDARD SECTION
45GSR10 - 10 Section
45GSR20 - 20 Section
14 1/2
9 21/32
16 3/4
Optional double braced sections
are available upon request.
Optional Waveguide
Brackets (KY2041A)
1 1/4 O.D.
Solid Round
7/16 O.D.
Solid Bracing
1 1/4 O.D.
Solid Round
7/16 O.D.
Solid Bracing
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
P/N 45GSR90R040

47
35
32
1/4 EHS
(665#)
73.8
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
101.8
B UY E R S GUI DE
S TA NDA R D DE S I GNS - 4 5 GS R
9 0 MP H R E V. G [ 3 S E C ON D G U S T ]
72
P/N 45GSR90R040

Tower Model
Windspeed (Rev. G) ROHN Tower
Tower Height (ft.)
EPA= Effective Projected Area
2011 ROHN PRODUCTS LLC
Guy Initial Tension
This document is to serve as a guide for sizing and purchasing the 45GSR tower. Tower and foundation installations should
be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites
located on unusual terrain.
3. Designs assume two 7/8 diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60 Fahrenheit.
6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 93-97.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
Design Criteria
S O L I D R O D
45 45GSR GSR
S TA NDA R D DE S I GN - 4 5 GS R
9 0 MP H R E V. G
40 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R040
P/N: 45GSR90R040
40 TOWER
35
95.0 73.8 OR
47
32
1/4EHS
(665#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
73
2011 ROHN PRODUCTS LLC
60 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R060
P/N: 45GSR90R060
60 TOWER
55
90.4 66.7 OR
73
48
1/4EHS
(665#)
P/N: 45GSR90R080
80 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R080
80 TOWER
75
82.6 62.9 OR
99
64
1/4EHS
(665#)
73
35
50 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R050
P/N: 45GSR90R050
50 TOWER
45
95.0 70.0 OR
60
40
1/4EHS
(665#)
P/N: 45GSR90R070
70 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R070
70 TOWER
65
86.5 64.9 OR
86
56
1/4EHS
(665#)
66
35
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
2 1 1
150 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
2 1
200 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
1
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1
250 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1
500 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
2
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1 2
550 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
9 0 MP H R E V. G
74
2011 ROHN PRODUCTS LLC
100 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R100
P/N: 45GSR90R100
100 TOWER
95
78.0 58.4 OR
124
80
1/4EHS
(665#)
97
55
120 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R120
P/N: 45GSR90R120
120 TOWER
115
73.5 54.2 OR
150
96
1/4EHS
(665#)
122
75
35 102
P/N: 45GSR90R090
90 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R090
90 TOWER
85
80.3 60.4 OR
111
72
1/4EHS
(665#)
85
45
110 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R110
P/N: 45GSR90R110
110 TOWER
105
75.4 56.6 OR
137
88
1/4EHS
(665#)
109
65
35 95
130 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R130
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1
625 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
2
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 2
725 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1
1100 18 18 9 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
3
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 3
1200 18 18 9 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
P/N: 45GSR90R130
130 TOWER
118
65.0 49.8 OR
157
104
5/16EHS
(1,120#)
134
85
45 113
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1
800 12
12 3
3 3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
3
45GSR10
1
142265
500
BG2146
6
7/16THH
6
1/2TBE&J
6
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
9 0 MP H R E V. G
75
2011 ROHN PRODUCTS LLC
P/N: 45GSR90R140
140 TOWER
128
63.5 48.9 OR
170
112
5/16EHS
(1,120#)
147
95
55 125
140 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R140
1/4EHS
(665#)
P/N: 45GSR90R160
160 TOWER
148
60.4 47.0 OR
196
128
5/16EHS
(1,120#) 172
115
35 133
75
148
1/4EHS
(665#)
160 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R160
P/N: 45GSR90R150
150 TOWER
138
62.2 48.2 OR
183
120
159
105
35 125
65
136
5/16EHS
(1,120#)
150 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R150
P/N: 45GSR90R170
170 TOWER
158
59.9 46.4 OR
208
136
185
125
45 143
85
160
1/4EHS
(665#)
170 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R170
5/16EHS
(1,120#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS&
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1
875 12
12 3
3 3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
3
142265
550
BG2146
6
7/16THH
6
1/2TBE&J
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1
1350 18
18 3
3 3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
4
45GSR10
1
142265
600
BG2146
6
7/16THH
6
1/2TBE&J
9
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
8 1
1450 18
18 3
3 3 3 1 3
FDNS
BASE ANCHOR
AB2 FB1G
GA45GD
4
142265
625
BG2146
6
7/16THH
6
1/2TBE&J
9
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J TBSAFETY
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
8 1
1575 18
18 12 3
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB1G
GA45GD
4
45GSR10
1
142265
675
BG2146
6
7/16THH
6
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
9 0 MP H R E V. G
76
2011 ROHN PRODUCTS LLC
P/N: 45GSR90R200
200 TOWER
188
56.1 44.6 OR
247
160
5/16EHS
(1,120#) 223
155
35
115
197
1/4EHS
(665#)
177
164
75
P/N: 45GSR90R190
190 TOWER
178
57.0 45.2 OR
234
152
210
145
35
105
185
5/16EHS
(1,120#)
165
156
65
1/4EHS
(665#)
P/N: 45GSR90R180
180 TOWER
168
58.5 45.7 OR
221
144
5/16EHS
(1,120#) 197
135
55 154
95
173
1/4EHS
(665#)
180 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R180
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J TBSAFETY
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
9 1
1675 18
18 12 3
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB1G
GA45GD
4
142265
725
BG2146
6
7/16THH
6
190 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R190
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J TBSAFETY
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
9 1
2300 24
24 15 3
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB1G
GA45GD
5
45GSR10
1
142265
750
BG2146
6
7/16THH
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J TBSAFETY
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
10 1
2425 24
24 15 3
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB1G
GA45GD
5
142265
800
BG2146
6
7/16THH
6
200 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R200
APL4A
1
P/N: 45GSR90R220
220 TOWER
208
54.2 43.5 OR
272
176
1/4EHS
(665#)
248
175
55
135
222
95
184
200
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J TBSAFETY
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
11 1
2725 24
24 15 3
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB1G
GA45GD
5
142265
875
BG2146
6
7/16THH
6
220 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R220
APL4A
1
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
9 0 MP H R E V. G
77
2011 ROHN PRODUCTS LLC
P/N: 45GSR90R240
240 TOWER
228
52.5 42.6 OR
298
192
1/4EHS
(665#)
274
195
35
115
75
102
122
5/16EHS
(1,120#)
247
150
155
96
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
12 1
2850 30
30 3
6 6 6 2 3
BASE
INNER
ANCHOR
AB2 FB1G
GA45GD
6
142265
950
BG2146
6
7/16THH
6
240 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R240
1/2TBE&J
15
APL4A
1
P/N: 45GSR90R260
260 TOWER
248
51.1 41.8 OR
324
208
5/16EHS
(1,120#) 299
215
55
135
95
125
147
1/4EHS
(665#)
272
175
175
112
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144
3/8THH 5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
13 1
3250 30
30 3
6 6 6 2 3
BASE
FB1G
GA45GD
6
142265
1050
BG2146
6
7/16THH
6
260 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R260
1/2TBE&J
15
APL4A
1
P/N: 45GSR90R280
280 TOWER
268
50.0 40.9 OR
349
224
5/16EHS
(1,120#) 325
235
75
155
115
122
150
1/4EHS
(665#)
297
272
195
96
35
102
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGXBGK3GGX
14 1
4050 36 36
12
6 3 2 3
BASE
FB1G
GA45GD
7
142265
1125
BG2146
6
7/16THH
6
1/2TBE&J
9
APL4A
1
CPC.5/.75
3
CPC1/1.25
3
GAC5655TOP
3
280 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R280
P/N: 45GSR90R300
300 TOWER
288
48.9 40.1 OR
375
240
1/4EHS
(665#)
350
255
95
175
135
147
175
5/16EHS
(1,120#)
322
297
215
112
55
125
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGXBGK3GGX
15 1
4525 36 36
12
6 3 2 3
BASE
FB1G
GA45GD
7
142265
1200
BG2146
6
7/16THH
6
1/2TBE&J
9
APL4A
1
CPC.5/.75
3
CPC1/1.25
3
GAC5655TOP
3
300 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R300
OUTER
ANCHOR
AB2
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB2
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB3
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB3
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
9 0 MP H R E V. G
78
2011 ROHN PRODUCTS LLC
P/N: 45GSR90R320
320 TOWER
308
47.7 39.5 OR
400
256
5/16EHS
(1,120#) 376
275
75
195
155
1/4EHS
(665#)
348
322
235
128
35
133
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGXBGK3GGX
16 1
5450 42 42
12
6 3 2 3
BASE
FB1G
GA45GD
8
142265
1275
BG2146
6
7/16THH
6
1/2TBE&J
12
APL4A
1
CPC.5/.75
3
CPC1/1.25
3
GAC5655TOP
3
320 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R320
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGXBGK3GGX
17 1
5975 42 42
12
6 3 2 3
BASE
FB1G
GA45GD
8
142265
1375
BG2146
6
7/16THH
6
1/2TBE&J
12
APL4A
1
CPC.5/.75
3
CPC1/1.25
3
GAC5655TOP
3
340 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR90R340
115
148
201
172
P/N: 45GSR90R340
340 TOWER
328
46.8 38.9 OR
426
272
5/16EHS
(1,120#) 401
295
95
215
175
1/4EHS
(665#)
373
347
255
144
55
154
135
173
227
197
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB3
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB3
S O L I D R O D
45 45GSR GSR
S TA NDA R D DE S I GN - 4 5 GS R
1 1 0 MP H R E V. G
40 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R040
P/N: 45GSR110R040
40 TOWER
35
66.9 48.2 OR
47
32
1/4EHS
(665#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
79
2011 ROHN PRODUCTS LLC
60 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R060
P/N: 45GSR110R060
60 TOWER
55
57.5 38.3 OR
73
48
1/4EHS
(665#)
P/N: 45GSR110R080
80 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R080
80 TOWER
75
52.7 35.5 OR
99
64
1/4EHS
(665#)
73
35
50 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R050
P/N: 45GSR110R050
50 TOWER
45
63.1 46.0 OR
60
40
1/4EHS
(665#)
P/N: 45GSR110R070
70 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R070
70 TOWER
65
57.2 42.4 OR
86
56
1/4EHS
(665#)
66
35
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
2 1 1
150 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
2 1
200 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
1
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1
250 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1
500 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
2
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1 2
550 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 1 0 MP H R E V. G
80
2011 ROHN PRODUCTS LLC
100 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R100
P/N: 45GSR110R100
100 TOWER
88
44.5 32.6 OR
119
80
1/4EHS
(665#)
97
55
P/N: 45GSR110R090
90 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R090
90 TOWER
85
49.4 33.0 OR
111
72
1/4EHS
(665#)
85
45
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
4 1
625 12 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
2
45GSR10
1
5/16EHS
(1,120#)
P/N: 45GSR110R110
110 TOWER
98
43.0 31.7 OR
132
88
1/4EHS
(665#)
109
65
35 95
5/16EHS
(1,120#)
P/N: 45GSR110R120
120 TOWER
108
41.4 30.7 OR
144
96
1/4EHS
(665#)
122
75
35 102
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 1/2TBE&J 5/8TBE&J
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 2
325 400 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 6 6 3
TOWER PARTS
INCLUDED
GUY WIRE &
CONNECTION
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 1/2TBE&J 5/8TBE&J
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
5 1 3
650 425 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 12 6 3
45GSR10
1
120 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R120
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 1/2TBE&J 5/8TBE&J
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 3
725 475 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 12 6 3
110 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R110
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 1 0 MP H R E V. G
81
2011 ROHN PRODUCTS LLC
P/N: 45GSR110R140
140 TOWER
128
39.4 29.3 OR
170
112
5/16EHS
(1,120#)
147
95
55 125
1/4EHS
(665#)
P/N: 45GSR110R160
160 TOWER
148
37.5 28.2 OR
196
128
5/16EHS
(1,120#) 172
115
35 133
75
148
1/4EHS
(665#)
P/N: 45GSR110R150
150 TOWER
138
38.3 28.7 OR
183
120
159
105
35 125
65
136
5/16EHS
(1,120#)
1/4EHS
(665#)
P/N: 45GSR110R130
130 TOWER
118
40.5 29.9 OR
157
104
5/16EHS
(1,120#)
134
85
45 113
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 1/2TBE&J 5/8TBE&J
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
6 1 3
800 500 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 12 6 3
45GSR10
1
130 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R130
140 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R140
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 1/2TBE&J 5/8TBE&J
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
7 1 3
875 550 12 6 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 12 6 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
7 1 4
1350 600 18 12
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 18 6 3
45GSR10
1
150 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R150
160 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R160
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
8 1 4
1450 625 18 12
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 18 6 3
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 1 0 MP H R E V. G
82
2011 ROHN PRODUCTS LLC
P/N: 45GSR110R200
200 TOWER
188
34.6 26.6 OR
247
160
5/16EHS
(1,120#) 223
155
35
115
197
1/4EHS
(665#)
177
164
75
P/N: 45GSR110R190
190 TOWER
178
35.1 26.9 OR
234
152
210
145
35
105
185
5/16EHS
(1,120#)
165
156
65
1/4EHS
(665#)
P/N: 45GSR110R180
180 TOWER
168
35.7 27.3 OR
221
144
5/16EHS
(1,120#) 197
135
55 154
95
173
1/4EHS
(665#)
P/N: 45GSR110R170
170 TOWER
158
36.8 27.8 OR
208
136
185
125
45 143
85
160
1/4EHS
(665#)
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
8 1 4
1575 675 18 12
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 18 6 3
45GSR10
1
170 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R170
180 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R180
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
9 1 4
1675 725 18 12
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 18 6 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
9 1 5
2300 750 24 15
3 3 1 3
FDNS
BASE ANCHOR
AB3 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 24 6 3
45GSR10
1
190 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R190
200 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R200
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
10 1 5
2425 800 24 15
3 3 1 3
FDNS
BASE ANCHOR
AB4 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 24 6 3
APL4A
1
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 1 0 MP H R E V. G
83
2011 ROHN PRODUCTS LLC
P/N: 45GSR110R240
240 TOWER
228
32.2 25.1 OR
298
192
1/4EHS
(665#)
274
195
35
115
75
102
122
5/16EHS
(1,120#)
247
150
155
96
P/N: 45GSR110R260
260 TOWER
248
31.0 24.5 OR
324
208
5/16EHS
(1,120#) 299
215
55
135
95
125
147
1/4EHS
(665#)
272
175
175
112
P/N: 45GSR110R280
280 TOWER
268
30.4 24.0 OR
349
224
5/16EHS
(1,120#) 325
235
75
155
115
122
150
1/4EHS
(665#)
297
272
195
96
35
102
P/N: 45GSR110R220
220 TOWER
208
33.3 25.8 OR
273
176
1/4EHS
(665#)
248
175
55
135
222
95
184
200
5/16EHS
(1,120#)
220 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R220
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB GA45GD
1/4EHS 142265 3/8THH 5/8TBE&J
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
11 1 5
2725 875 24 15
3 3 1 3
FDNS
BASE ANCHOR
AB4 FB2G
7/16THH BG2144 BG2146 TBSAFETY
6 24 6 3
APL4A
1
260 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R260
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX
CPC.5/.75
12 1
2850 30 30
9
6 3
3
2 3
BASE
INNER
ANCHOR
AB2 FB2G
GA45GD
6
142265
950
BG2146
6
7/16THH
6
240 ROHN 45GSR
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 45GSR110R240
1/2TBE&J
9
APL4A
1
CPC1/1.25
3
GAC5655TOP
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX
CPC.5/.75
13 1
3250 30 30
9
6 3
3
2 3
BASE
FB2G
GA45GD
6
142265
1050
BG2146
6
7/16THH
6
1/2TBE&J
9
APL4A
1
CPC1/1.25
3
GAC5655TOP
3
OUTER
ANCHOR
AB3
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB3
280 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R280
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX
CPC.5/.75
14 1
4050 36 36
12
6 3
3
2 3
BASE
FB2G
GA45GD
7
142265
1125
BG2146
6
7/16THH
6
1/2TBE&J
9
APL4A
1
CPC1/1.25
3
GAC5655TOP
3
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB4
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 1 0 MP H R E V. G
84
2011 ROHN PRODUCTS LLC
P/N: 45GSR110R300
300 TOWER
288
29.7 23.5 OR
375
240
1/4EHS
(665#)
345
248
95
175
135
147
175
5/16EHS
(1,120#)
322
297
215
112
55
125
300 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R300
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2144 3/8THH
5/8TBE&J
TBSAFETY GAC3455TOP AGK1GGX BGK3GGX
CPC.5/.75
15 1
3400 30 30
12
6 3
3
2 3
BASE
FB2G
GA45GD
7
142265
2300
BG2146
12
7/16THH
12
1/2TBE&J
9
APL4A
1
CPC1/1.25
3
GAC5655TOP
3
INNER
ANCHOR
AB2
OUTER
ANCHOR
AB4
320 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R320
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2146
1/2THH 5/8TBE&J
TBSAFETY AGK1GGX BGK3GGX
15 1
4225 6
6 24
6 2 3
BASE
FB2G
GA45GD
7
142265
1200
BG2147
6
7/16THH
6
5/8S
3
APL4A
1
CPC1/1.25
6
GAC5655TOP
6
INNER
ANCHOR
AB3
OUTER
ANCHOR
AB4
P/N: 45GSR110R320
320 TOWER
308
28.9 23.0 OR
401
256
5/16EHS
(1,120#)
371
268
75
195
155
1/4EHS
(665#)
348
322
235
128
35
133
115
148
201
172
P/N: 45GSR110R340
340 TOWER
328
28.1 22.6 OR
426
272
5/16EHS
(1,120#)
396
288
95
215
175
1/4EHS
(665#)
373
347
255
144
55
154
135
173
227
197
3/8EHS
(1,540#)
142261
1300
3/8THH
36
BG2144
36
5/8S
3
45GSR20L82*
1
340 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR110R340
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR2045GSRSB
1/4EHS BG2146
1/2THH 5/8TBE&J
TBSAFETY AGK1GGX BGK3GGX
16 1
4700 6
6 24
6 2 3
BASE
FB2G
GA45GD
7
142265
1275
BG2147
6
7/16THH
6
5/8S
3
APL4A
1
CPC1/1.25
6
GAC5655TOP
6
INNER
ANCHOR
AB3
OUTER
ANCHOR
AB4
142261
1375
3/8THH
36
BG2144
36
5/8S
3
45GSR20L82*
1
3/8EHS
(1,540#)
* Guy lug sections required for 3/8 guys.
S O L I D R O D
45 45GSR GSR
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
40 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R040
P/N: 45GSR130R040
40 TOWER
35
47.3 33.5 OR
47
32
1/4EHS
(665#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
85
2011 ROHN PRODUCTS LLC
60 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R060
P/N: 45GSR130R060
60 TOWER
48
35.0 24.0 OR
68
48
5/16EHS
(1,120#)
50 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR90R050
P/N: 45GSR130R050
50 TOWER
45
44.1 28.6 OR
60
40
1/4EHS
(665#)
P/N: 45GSR130R070
70 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R070
70 TOWER
58
33.2 22.8 OR
81
56
1/4EHS
(665#) 66
35
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
2 1 1
150 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH 1/2TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
2 1
200 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
1
45GSR10
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB GA45GD
142265 BG2146 7/16THH 5/8TBE&J TBSAFETY
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 1 1
225 6 6 3 3
3 3 1 3
FDNS
BASE ANCHOR
AB2 FB2G
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH
1/2TBE&J TBSAFETY
3 1
225 6 6
3 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
2
45GSR10
1
5/16EHS
(1,120#)
142265
275
5/8TBE&J
3
7/16THH
6
BG2146
6
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 3 1 3
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
86
2011 ROHN PRODUCTS LLC
P/N: 45GSR130R100
100 TOWER
88
29.1 20.5 OR
119
80
1/4EHS
(665#)
97
55
P/N: 45GSR130R090
90 TOWER
78
30.2 21.1 OR
106
72
1/4EHS
(665#)
85
45
P/N: 45GSR130R110
110 TOWER
98
28.0 19.9 OR
132
88
1/4EHS
(665#)
109
65
35 95
P/N: 45GSR130R080
80 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R080
80 TOWER
68
31.5 21.9 OR
93
64
1/4EHS
(665#)
73
35
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH
1/2TBE&J TBSAFETY
4 1
250 6 6
3 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
2
142265
300
5/8TBE&J
3
7/16THH
6
BG2146
6
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH
1/2TBE&J TBSAFETY
4 1
275 6 6
3 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
2
45GSR10
1
142265
350
5/8TBE&J
3
7/16THH
6
BG2146
6
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 3 1 3
90 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R090
5/16EHS
(1,120#)
100 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R100
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144 3/8THH
1/2TBE&J TBSAFETY
5 1
325 6 6
3 3
FDNS
BASE ANCHOR
AB2 FB2G
GA45GD
2
142265
400
5/8TBE&J
3
7/16THH
6
BG2146
6
GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75
3 3 1 3
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
5 1
650 12
12 3
FDNS
BASE ANCHOR
AB3 FB2G
GA45GD
3
45GSR10
1
142265
425
5/8TBE&J
9
7/16THH
6
BG2146
6
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
3 3 1 3
110 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R110
5/16EHS
(1,120#)
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
87
2011 ROHN PRODUCTS LLC
120 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R120
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
6 1
725 12
12 3
FDNS
BASE ANCHOR
AB3 FB2G
GA45GD
3
142265
475
5/8TBE&J
9
7/16THH
6
BG2146
6
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
6 1
800 12
12 3
FDNS
BASE ANCHOR
AB3 FB2G
GA45GD
3
45GSR10
1
142265
500
5/8TBE&J
9
7/16THH
6
BG2146
6
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
3 3 1 3
130 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R130
P/N: 45GSR130R120
120 TOWER
108
27.0 19.3 OR
144
96
1/4EHS
(665#)
122
75
35 102
P/N: 45GSR130R130
130 TOWER
118
26.3 18.7 OR
157
104
5/16EHS
(1,120#)
134
85
45 113
1/4EHS
(665#)
5/16EHS
(1,120#)
140 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R140
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
7 1
875 12
12 3
FDNS
BASE ANCHOR
AB3 FB2G
GA45GD
3
142265
550
5/8TBE&J
9
7/16THH
6
BG2146
6
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
3 3 1 3
P/N: 45GSR130R140
140 TOWER
128
25.6 18.4 OR
170
112
5/16EHS
(1,120#)
147
95
55 125
1/4EHS
(665#)
P/N: 45GSR130R150
150 TOWER
138
24.7 18.0 OR
183
120
159
105
35 125
65
136
5/16EHS
(1,120#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
7 1
1350 18
18 3
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
4
45GSR10
1
142265
600
3/4TBE&J
12
7/16THH
6
BG2146
6
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
150 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R150
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
88
2011 ROHN PRODUCTS LLC
160 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R160
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
8 1
1450 18
18 3
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
4
142265
625
3/4TBE&J
12
7/16THH
6
BG2146
6
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
8 1
1575 18
18 3
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
4
45GSR10
1
142265
675
3/4TBE&J
12
7/16THH
6
BG2146
6
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
170 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R170
P/N: 45GSR130R160
160 TOWER
148
24.0 17.7 OR
196
128
5/16EHS
(1,120#) 172
115
35 133
75
148
1/4EHS
(665#)
P/N: 45GSR130R170
170 TOWER
158
23.4 17.3 OR
208
136
185
125
45 143
85
160
1/4EHS
(665#)
5/16EHS
(1,120#)
P/N: 45GSR130R190
190 TOWER
178
22.3 16.5 OR
234
152
210
145
35
105
185
5/16EHS
(1,120#)
165
156
65
1/4EHS
(665#)
P/N: 45GSR130R180
180 TOWER
168
22.8 16.9 OR
221
144
5/16EHS
(1,120#) 197
135
55 154
95
173
1/4EHS
(665#)
180 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R180
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
9 1
1675 18
18 3
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
4
142265
725
3/4TBE&J
12
7/16THH
6
BG2146
6
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
9 1
2300 24
24 3
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
5
45GSR10
1
142265
750
3/4TBE&J
15
7/16THH
6
BG2146
6
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
190 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R190
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
89
2011 ROHN PRODUCTS LLC
P/N: 45GSR130R240
240 TOWER
228
20.2 15.0 OR
298
192
1/4EHS
(665#)
269
188
35
108
75
102
122
5/16EHS
(1,120#)
247
144
155
96
P/N: 45GSR130R200
200 TOWER
188
21.9 16.2 OR
247
160
5/16EHS
(1,120#) 218
148
35
115
197
1/4EHS
(665#)
177
164
75
P/N: 45GSR130R220
220 TOWER
208
21.0 15.5 OR
272
176
1/4EHS
(665#)
243
168
55
135
222
95
184
200
5/16EHS
(1,120#)
200 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R200
220 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R220
3/8EHS
(1,540#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS BG2144
3/8THH TBSAFETY
10 1
1725 18
18 3
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
5
142265
1500
3/4TBE&J
15
7/16THH
12
BG2146
12
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
APL4A
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
10 1
1950 875
6 6
FDNS
BASE ANCHOR
AB4 FB2G
GA45GD
4
142265
775
7/16THH
6
BG2147
6
BG2144
18
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
3 3 1 3
APL4A
1
3/8THH TBSAFETY
18 3
3/4TBE&J
15
5/8S
3
240 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R240
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
11 1
1500 950
12 6
BASE
INNER
ANCHOR
AB3 FB2G
GA45GD
5
142265
1325
7/16THH
12
BG2147
6
BG2144
18
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
6 6 2 3
APL4A
1
3/8THH TBSAFETY
18 6
5/8TBE&J
18
5/8S
3
3/8EHS
(1,540#)
OUTER
ANCHOR
AB4
45GSR20L82*
1
45GSR20L82*
1
* Guy lug section required for 3/8 guys.
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
90
2011 ROHN PRODUCTS LLC
260 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R260
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
12 1
1750 1050
12 6
BASE
INNER
ANCHOR
AB3 FB2G
GA45GD
5
142265
1500
7/16THH
12
BG2147
6
BG2144
18
GAC5655TOP AGK1GGX BGK3GGX CPC1/1.25
6 6 2 3
APL4A
1
3/8THH TBSAFETY
18 6
5/8TBE&J
18
5/8S
3
OUTER
ANCHOR
AB4
45GSR20L82*
1
P/N: 45GSR130R260
260 TOWER
248
19.6 14.6 OR
324
208
3/8EHS
(1,540#) 294
208
55
128
95
125
147
1/4EHS
(665#)
272
170
175
112
P/N: 45GSR130R280
280 TOWER
268
19.0 14.3 OR
349
224
3/8EHS
(1,540#) 320
228
75
148
115
122
150
1/4EHS
(665#)
292
268
188
96
35
102
P/N: 45GSR130R300
300 TOWER
288
18.4 14.0 OR
375
240
1/4EHS
(665#)
345
248
95
168
135
147
175
3/8EHS
(1,540#)
318
293
208
112
55
125
280 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R280
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
13 1
1200 1125
18 6
BASE
INNER
ANCHOR
AB3 FB2G
GA45GD
6
142265
2800
7/16THH
18
BG2147
6
BG2144
18
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
6 6 2 3
APL4A
1
3/8THH TBSAFETY
18 6
3/4TBE&J
21
5/8S
3
OUTER
ANCHOR
AB5
45GSR20L82*
1
5/16EHS
(1,120#)
300 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R300
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
14 1
1425 1200
18 6
BASE
INNER
ANCHOR
AB3 FB3G
GA45GD
6
142265
3050
7/16THH
18
BG2147
6
BG2144
18
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
6 6 2 3
APL4A
1
3/8THH TBSAFETY
18 6
3/4TBE&J
21
5/8S
3
OUTER
ANCHOR
AB5
45GSR20L82*
1
5/16EHS
(1,120#)
5/16EHS
(1,120#)
* Guy lug section required for 3/8 guys.
S O L I D R O D
45 45GSR GSR
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D DE S I GN - 4 5 GS R
1 3 0 MP H R E V. G
91
2011 ROHN PRODUCTS LLC
320 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R320
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
14 1
1450 2475
18 12
BASE
INNER
ANCHOR
AB3 FB3G
GA45GD
6
142265
2750
7/16THH
18
BG2147
12
BG2144
18
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
6 6 2 3
APL4A
1
3/8THH TBSAFETY
18 6
3/4TBE&J
24
5/8S
6
OUTER
ANCHOR
AB5
45GSR20L82*
2
P/N: 45GSR130R320
320 TOWER
308
17.8 13.8 OR
400
256
3/8EHS
(1,540#) 371
268
75
188
148
1/4EHS
(665#)
343
318
228
128
35
133
115
148
196
172
P/N: 45GSR130R340
340 TOWER
328
17.4 12.5 OR
426
272
3/8EHS
(1,540#) 396
288
95
208
168
1/4EHS
(665#)
368
342
248
144
55
154
135
173
221
197
340 ROHN 45GSR
Al l par t s shown i n t abl e
are i ncl uded when order i ng
Par t No: 45GSR130R340
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
45GSR20 45GSRSB
1/4EHS 142261
BG2146 1/2THH
14 1
1675 3800
12 18
BASE
INNER
ANCHOR
AB4 FB3G
GA45GD
5
142265
1800
7/16THH
12
BG2147
18
BG2144
18
GAC5755TOP AGK1GGX BGK3GGX CPC1.5/2
6 6 2 3
APL4A
1
3/8THH TBSAFETY
18 6
3/4TBE&J
24
5/8S
9
OUTER
ANCHOR
AB5
45GSR20L82*
3
5/16EHS
(1,120#)
5/16EHS
(1,120#)
* Guy lug section required for 3/8 guys.
PA R T S & ACC E S S OR I E S
TAPERED BASE
45GSRTBPP*
FOR USE WITH PIER PIN (3/4X12PP) AND
BEARING PLATE (BP6) SOLD SEPARATELY.
MID BEACON PLATE
/ ICE SHIELD
APL1258UM
3 SIDE ARM WITH (2) TIE BACKS
KY1653A
MOUNTING TUBE PROVIDED IS 3 LONG,
2 - 3/8 O.D.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
92
2011 ROHN PRODUCTS LLC
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
17
Beacon Plate
Ice Shield
LEG MOUNTED
BEACON PLATE KIT
APL4A
FOR MOUNTING BEACON OR
LIGHTNING ROD. BOLTS TO
TOP OF STANDARD SECTION.
INCLUDES BEACON PLATE,
(2) CAP PLATES, NUTS AND BOLTS.
LIGHTNING ROD
PLATE KIT
VW132
INCLUDES: LIGHTNING ROD PLATE,
NUTS AND BOLTS.
LIGHTNING ROD
LRCL
5 COPPER CLAD
ORDERED SEPARATELY.
4.3 SHORT BASE
45GSRSB
FOR EMBEDMENT IN CONCRETE.
Refer to pages 63-65 for the following accessories that also ft the 45GSR tower:
Pier Pin (3/4x12PP)
Side Arm Bracket (SA253UA)
Dish Mount (VY4311A2 & VY4311A)
Face Mount (DM45G2 & DM454)
Universal House Bracket (HBUTVRO)
Torque Bar (TB45D)
Guy Bracket (GA45GD)
Anti-Climb Panels (VW913A)
Work Platform (WP45G)
Safety Ring (SR245)
Climbing Harness (TTFBH-4D & TTFBH-C/P)
Safety Cable Slider (TT-WG-500-W/SMC)
Safety Cable System (See page 65 for P/N)
G
GUY E D T OWE R S - 4 5 GS R
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
93
2011 ROHN PRODUCTS LLC
REV G
ANCHOR GROUNDING
AGK1GGX
REV G
BASE GROUNDING
BGK3GGX
A NC HOR I NF OR MAT I ON
3/8
2
12
3/4 P/N STAMPED HERE
GAC3455TOP
1/2
2 1/2
12
120
1 1/4 P/N STAMPED HERE
GAC5655TOP
81
3/4
3
12
168
1 7/16 P/N STAMPED HERE
GAC5755TOP
11/16
13/16
15/16
4 x 4 x 3/8 angle
5 x 5 x 3/8 angle
C
L
of hole to edge
of plate = 1 1/4
C
L
of hole to edge
of plate = 1
C
L
of hole to edge
of plate = 1 1/4
5 x 5 x 3/8 angle
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp
6 Min.
Attach to leg with
supplied leg clamp
Ground Wire
6 Min.
Ground Rod Clamp
Ground Rod,
3 provided (to be installed
at 120 separation at 20 spacing.
o
All around stirrups
equally spaced 12
O.C. anchored with 90
hooks around a
horizontal bar
Top and bottom
horizontal bars
equally spaced
C
B
A
Ground Line
D
Anchor rod
o
Additional bar at
center-line each
side, when required
S TA NDA R D A NC HOR B L OC K S
Block
AB2
AB3
AB4
AB5
AB6
A
4 - 0
6 - 0
6 - 0
8 - 0
8 - 0
Concrete Vol.
(Cu. Yds.)
1.33 Per Block
4.0 Total for 3
1.0 Per Block
3.0 Total for 3
2.0 Per Block
6.0 Total for 3
2.22 Per Block
6.7 Total for 3
2.96 Per Block
8.9 Total for 3
B
1 - 6
1 - 6
1 - 6
2 - 0
2 - 0
C
4 - 0
3 - 0
4 - 0
3 - 0
4 - 0
Horizontal Bars
(Qty. & Size)
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer
(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer
(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer
(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
D
6 - 0
6 - 0
9 - 0
10 - 0
10 - 0
Anchor Dimensions (in.)
Stirrup Size
& Spacing
#3 @ 12 O.C.
#3 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
94
2011 ROHN PRODUCTS LLC
Refer to pages 95-96 for anchor rod installation angles.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
95
2011 ROHN PRODUCTS LLC
A NC HOR R OD I NS TA L L AT I ON A NGL E S
120
o
Ground Line
Rod Angle
(in degrees)
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Inner
Rod
Angle
48
49
49
44
43
44
44
42
42
42
42
40
40
40
41
40
40
40
38
40
38
40
37
38
45GSR | 90MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
46
46
44
44
45
45
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
Inner
Rod
Angle
48
49
49
43
42
43
44
41
41
41
42
40
40
40
40
40
40
40
39
40
39
40
40
40
45GSR | 110MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
45
45
43
44
44
44
See the following page for 45GSR | 130mph anchor rod slopes.
Tower Plan Anchor Rod Angle
A NC HOR R OD I NS TA L L AT I ON A NGL E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
96
2011 ROHN PRODUCTS LLC
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
Inner
Rod
Angle
48
48
45
42
42
43
43
40
40
41
41
39
38
39
39
37
38
38
40
41
38
39
37
38
45GSR | 130MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC5655TOP
GAC5655TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
45
45
42
43
43
43
120
o
Ground Line
Rod Angle
(in degrees)
Tower Plan Anchor Rod Angle
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
97
2011 ROHN PRODUCTS LLC
S TA NDA R D MAT F OUNDAT I ON
F OR 4 5 G S R T OWE R S
Base
FB1G
FB2G
FB3G
Mat Width
(W)
4 - 6
5-3
6-3
Concrete Vol.
(Cu. Yds.)
3.0
4.1
5.8
Grade
W
(Square)
No. 7 Bars 12 O.C., each
way, top and bottom
4 0
2 min. projection above
the fnished concrete
45GSR Tower Section
or Short Base Section,
placed with center of
tower at center of
foundation
0 to 3
6
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D ME T E OR OL OGI C A L T OWE R S
98
2011 ROHN PRODUCTS LLC
60MMET
4 Guy Elevations
1 Fixed Base Foundation
1 Anchor Radius
ANSI/TIA-222-G
110 MPH - 3 Second Gust (No Ice)
50 MPH - 3 Second Gust (3/4 Radial Ice)
Structure Class II
Exposure Category C
Topographic Category I
80MMET
5 Guy Elevations
1 Fixed Base Foundation
1 Anchor Radius
ANSI/TIA-222-G
110 MPH - 3 Second Gust (No Ice)
50 MPH - 3 Second Gust (3/4 Radial Ice)
Structure Class II
Exposure Category C
Topographic Category I
100MMET
6 Guy Elevations
1 Fixed Base Foundation
2 Anchor Radii
ANSI/TIA-222-G
110 MPH - 3 Second Gust (No Ice)
50 MPH - 3 Second Gust (3/4 Radial Ice)
Structure Class II
Exposure Category C
Topographic Category I
80 m
100 m
250
198
148
98
48
190
148
98
48

197
262
331
318
268
218
158
98
48
Complete Kit Includes:
- Assembly and foundation
drawings
- All necessary tower sections
- Tower short base
- All guy wire and connectors
- All guy anchors
- Base and anchor grounding kits
60 m
EPA / WT.
(no ice)
9.00 sq. ft. / 200 lbs.
9.00 sq. ft. / 200 lbs.
9.00 sq. ft. / 200 lbs.
EPA / WT.
(3/4radial ice)
25.00 sq. ft. / 600 lbs.
25.00 sq. ft. / 600 lbs.
25.00 sq. ft. / 600 lbs.
40 m
50 m
60 m
Boom
Height
EPA / WT.
(no ice)
9.00 sq. ft. / 200 lbs.
9.00 sq. ft. / 200 lbs.
9.00 sq. ft. / 200 lbs.
EPA / WT.
(3/4radial ice)
25.00 sq. ft. / 600 lbs.
25.00 sq. ft. / 600 lbs.
25.00 sq. ft. / 600 lbs.
60 m
70 m
80 m
Boom
Height
EPA / WT.
(no ice)
9.00 sq. ft. / 200 lbs.
9.00 sq. ft. / 200 lbs.
9.00 sq. ft. / 200 lbs.
EPA / WT.
(3/4radial ice)
25.00 sq. ft. / 600 lbs.
25.00 sq. ft. / 600 lbs.
25.00 sq. ft. / 600 lbs.
50 m
75 m
100 m
Boom
Height
Tower design assumes (1) elevator track over height of structure.
STANDARD SECTION
45GSR10 - 10 Section
45GSR20 - 20 Section
14 1/2
9 21/32
16 3/4
Double braced
sections provided
where required.
Optional Waveguide
Brackets (KY2041A)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 4 5 GS R
S TA NDA R D 4 5 GS R
ME T E OR OL OG I C A L T OWE R
99
2011 ROHN PRODUCTS LLC
1 1/4 O.D.
Solid Round
7/16 or 5/8 O.D.
Solid Bracing
156
210
106 / 264
Tower
Height
(m)
FB2G
FB3G
FB3G
Base
Foundation
No.
Guy Radius (ft.)
120 separation
o
AB4
AB5
AB2 / AB6
Anchor
Foundation
No.
60
80
100
Refer to page 288 for anchor rod details.
FOR FOUNDATION INFORMATION, PLEASE SEE
PAGES 94 & 97. FOR GENERAL INSTALLATION
INFORMATION, PLEASE SEE PAGES 147-153.
4.3 45GSR SHORT BASE
45GSRSB
TO BE EMBEDDED IN CONCRETE.
1 1/4 O.D.
Solid Round
7/16 O.D.
Solid Bracing
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all
engineering and warranty data supplied by ROHN. Materials used by others are
not the same quality and have not been tested or engineered by ROHN. Mixing
ROHN tower sections with non-ROHN products may cause tower failure or injury.
CAUTION
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D 5 5 G GUY E D T OWE R
100
2011 ROHN PRODUCTS LLC
The first. The original.
ROHN 55G
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 116 for ordering information.
REV. G
includes
REV. F&
GENERAL USE
The 55G lends itself to a wide variety of uses,
particularly where unusual wind loading and
height requirements exist. The 55G was designed
to provide excellent strength in heights up to
400.
FEATURES
Completely hot-dip galvanized after fabrication
Built on a 17 equilateral triangle design
High strength tubular legs joined by Zig-Zag

cross members
Each section contains all required nuts and bolts
shipped with section
Continuous solid round steel bracing
55G
1 1/2 O.D.
(11 GA.)
STANDARD SECTION
55G - 10 Section
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D 5 5 G GUY E D T OWE R
S E C T I ONS
101
9 13/16
7/16 O.D.
Solid Bracing
2011 ROHN PRODUCTS LLC
17
PARTS & ACCESSORIES PAGES 115-116
GROUNDING INFORMATION PAGE 117
FOUNDATION INFORMATION PAGES 117-120
QUICK REFERENCE
14 3/4
CONCRETE BASE PLATE
BPC55G*
FOR USE WITH 3/4X12PP PIER PIN
EMBEDDED IN CONCRETE.
Additional base sections are
available, please see page 115.
Optional double braced sections
are available upon request.
Optional Waveguide
Brackets (KY2041A)
* Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.
TOP PLATE
APL55G
FOR MOUNTING BEACON OR LIGHTNING ROD.
TOP PLATE BOLTS TO THE TOP OF
A STANDARD SECTION.
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
EPA (SQ. FT.), Revision F
P/N 55G90R100

117
90
85
42
80
3/16 EHS
(399#)
30.4
32.0
39.0
P/N 55G90R100

Tower Model
Windspeed (Rev. G) ROHN Tower
Tower Height (ft.)
EPA= Effective Projected Area
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
B UY E R S GUI DE
S TA NDA R D DE S I GNS - 5 5 G
9 0 MP H R E V. G [ 3 S E C ON D G U S T ]
7 0 MP H R E V. F [ FA S T E S T MI L E ]
102
2011 ROHN PRODUCTS LLC
1/4 EHS
(665#)
Guy Initial Tension
This document is to serve as a guide for sizing and purchasing the 55G tower. Tower and foundation installations should
be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites
located on unusual terrain.
3. Designs assume two 1/2 diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60 Fahrenheit.
6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material.
5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 117-120.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
Design Criteria
S TA NDA R D DE S I GN - 5 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
103
2011 ROHN PRODUCTS LLC
P/N: 55G90R120
120 TOWER
105
37.0 29.3 OR
142
96
3/16EHS
(399#)
122
75
35 102
1/4EHS
(665#)
P/N: 55G90R100
100 TOWER
85
39.0 30.4 OR
117
80
1/4EHS
(665#)
90
42
3/16EHS
(399#)
P/N: 55G90R110
110 TOWER
95
37.9 29.8 OR
129
88
1/4EHS
(665#)
100
47
3/16EHS
(399#)
P/N: 55G90R130
130 TOWER
115
36.1 28.7 OR
155
104
3/16EHS
(399#)
129
76
38 111
1/4EHS
(665#)
P/N: 55G90R140
140 TOWER
125
35.4 28.3 OR
168
112
3/16EHS
(399#)
139
83
41 119
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
10 1 1 2
300 375 6 6 6
3 1 3
100 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R100
FDNS
BASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
11 1 1 2
325 425 6 6 6
3 1 3
110 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R110
FDNS
BASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
12 1 1 3
725 475 12 6 12
3 1 3
120 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R120
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
13 1 1 3
775 500 12 6 12
3 1 3
130 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R130
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
14 1 1 3
825 550 12 6 12
3 1 3
140 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R140
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
32.0
31.2
30.4
29.8
29.0
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
104
2011 ROHN PRODUCTS LLC
P/N: 55G90R150
150 TOWER
135
34.7 27.9 OR
181
120
3/16EHS
(399#)
151
92
45 128
1/4EHS
(665#)
P/N: 55G90R160
160 TOWER
145
33.9 27.5 OR
193
128
3/16EHS
(399#)
160
96
48 137
1/4EHS
(665#)
P/N: 55G90R170
170 TOWER
155
33.3 27.2 OR
206
136
178
115
37 141
75
155
3/16EHS
(399#)
1/4EHS
(665#)
P/N: 55G90R180
180 TOWER
165
32.8 26.8 OR
219
144
190
124
42 150
83
166
3/16EHS
(399#)
1/4EHS
(665#)
P/N: 55G90R190
190 TOWER
175
32.4 26.5 OR
232
152
201
131
43 158
87
175
3/16EHS
(399#)
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
15 1 1 3
900 600 12 6 12
3 1 3
150 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R150
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
16 1 1 3
950 625 12 6 12
3 1 3
160 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R160
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
17 1 1 4
1525 675 18 6 18
3 1 3
170 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R170
FDNS
BASE ANCHOR
3/8THH
6 12
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
18 1 1 4
1625 700 18 6 18
3 1 3
180 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R180
FDNS
BASE ANCHOR
3/8THH
6 12
1/2TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS142265 BG2142BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
19 1 1 4
1700 750 18 6 18
3 1 3
190 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R190
FDNS
BASE ANCHOR
7/16THH
6 12
5/8TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB3
28.6
28.0
27.4
27.0
26.6
GAC3455TOP
GAC3455TOP 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
105
2011 ROHN PRODUCTS LLC
P/N: 55G90R200
200 TOWER
185
31.9 26.2 OR
245
160
212
139
47 167
93
185
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265BG2142BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
20 1 1 4
1800 800 18 6 18
3 1 3
200 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R200
FDNS
BASE ANCHOR
7/16THH
6 12
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5755TOP AGK1GGX BGK2GGX
22 1 1 5
2650 875 24 6 24
3 1 3
220 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R220
FDNS
BASE ANCHOR
7/16THH
6 15
3/4TBE&J
P/N: 55G90R220
220 TOWER
205
31.1 25.7 OR
270
176
241
164
41
123
215
3/16EHS
(399#)
194
181
82
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
AGK1GGX BGK2GGX
24 1 1 5
2900 950 24 6 24
3 1 3
240 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R240
FDNS
BASE ANCHOR
7/16THH
6 15
3/4TBE&J
P/N: 55G90R240
240 TOWER
225
30.3 25.3 OR
296
192
265
182
45
135
235
3/16EHS
(399#)
213
197
92
5/16EHS
(1,120#)
CPC1.5/2
3
TBSAFETY
3
CPC1.5/2
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
260 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R260
P/N: 55G90R260
260 TOWER
245
29.6 24.8 OR
321
208
5/16EHS
(1,120#)
202
42
162
122
77
104
3/16EHS
(399#)
64
82
241
264
290
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
GAC5655TOP BGK2GGX
CPC.5/.75
26 1 1 6
3
3 3
3/16EHS
3125
7/16THH
6
142265
1025
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
CPC1/1.25
3
AGK1GGX
2 3
CB2G AB3
CB2G AB3
CB3G AB3
BASE
INNER
ANCHOR
CB3G
OUTER
ANCHOR
AB3 AB2
24.2
23.4
22.8
22.2
5/16EHS
(1,120#)
GAC5755TOP
GAC3455TOP TBSAFETY
6
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
106
2011 ROHN PRODUCTS LLC
280 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R280
P/N: 55G90R280
280 TOWER
265
29.0 24.4 OR
347
224
5/16EHS
(1,120#)
222
43
175
132
82
110
3/16EHS
(399#)
70
85
260
284
315
300 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G90R300
P/N: 55G90R300
300 TOWER
285
28.4 24.1 OR
373
240
5/16EHS
(1,120#)
242
42
202
162
3/16EHS
(399#)
100
82
290
314
341
108
129
158
122
320 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G90R320
P/N: 55G90R320
320 TOWER
305
27.9 23.8 OR
398
256
5/16EHS
(1,120#)
262
42
215
172
3/16EHS
(399#)
100
82
308
334
366
108
129
160
125
340 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G90R340
P/N: 55G90R340
340 TOWER
325
27.4 23.5 OR
424
272
5/16EHS
(1,120#)
282
42
202
162
3/16EHS
(399#)
96
82
317
364
105
126
155
122
339
392 242
21.8
21.2
20.8
20.4
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
GAC5655TOP BGK2GGX
CPC.5/.75
28 1 1 6
3
3 3
3/16EHS
3350
7/16THH
6
142265
1125
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
CPC1/1.25
3
AGK1GGX
2 3
BASE
INNER
ANCHOR
CB4G
OUTER
ANCHOR
AB3 AB2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
CPC.5/.75
30 1 1 7
3
3 3
3/16EHS
4275
7/16THH
6
142265
1200
BG2142
36
1/2TBE&J
9
BG2146
6
5/8TBE&J
12
5/16THH
36
TBSAFETY
6
AGK1GGX
2 3
BASE
INNER
ANCHOR
CB4G
OUTER
ANCHOR
AB3 AB2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
32 1 1 7
3 3 3
3/16EHS
2250
7/16THH
6
1/4EHS
2250
BG2142
24
1/2TBE&J
9
BG2146
6
5/8TBE&J
12
BG2144
12
TBSAFETY
6
AGK1GGX
2 3
BASE
INNER
ANCHOR
CB4G
OUTER
ANCHOR
AB3 AB2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
34 1 1 8
3 3 3
3/16EHS
3325
7/16THH
6
142265
1350
BG2142
30
1/2TBE&J
9
BG2146
6
5/8TBE&J
15
5/16THH
30
TBSAFETY
6
AGK1GGX
2 3
BASE
INNER
ANCHOR
CB4G
OUTER
ANCHOR
AB3 AB2
142265
1275
1/4EHS
(665#)
1/4EHS
(665#)
1/4EHS
2425
GAC3455TOP
GAC5655TOP GAC3455TOP
GAC5655TOP GAC3455TOP
GAC5655TOP GAC3455TOP
TBSAFETY
6
CPC1/1.25
3
3/8THH
12
5/16THH
24
CPC1/1.25
3
CPC1/1.25
3
3/8THH
12
BG2144
12
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
107
2011 ROHN PRODUCTS LLC
360 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G90R360
P/N: 55G90R360
360 TOWER
345
27.0 23.2 OR
449
288
5/16EHS
(1,120#)
302
42
212
168
3/16EHS
(399#)
100
84
333
385
108
131
161
126
358
417 255
1/4EHS
(665#)
380 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G90R380
P/N: 55G90R380
380 TOWER
365
26.6 22.9 OR
475
304
5/16EHS
(1,120#)
319
45
227
181
3/16EHS
(399#)
110
92
354
409
119
143
174
135
379
441 273
1/4EHS
(665#)
P/N: 55G90R400
400 TOWER
385
26.1 22.7 OR
501
320
5/16EHS
(1,120#)
335
46
235
185
3/16EHS
(399#)
120
92
370
429
129
151
183
138
397
463 285
1/4EHS
(665#)
20.0
19.6
19.2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
36 1 1 8
3 3 3
3/16EHS
3475
5/16THH
30
1/4EHS
2575
3/8THH
12
142265
1450
7/16THH
6
BG2142
30
BG2144
12
1/2TBE&J
9
AGK1GGX
2 3
APL1258UM
2
BG2146
6
5/8TBE&J
15
BASE
INNER
ANCHOR
CB5G
OUTER
ANCHOR
AB4 AB2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
38 1 1 8
3 3
3/16EHS
3175
5/16THH
24
1/4EHS
3275
3/8THH
18
142265
1525
7/16THH
6
BG2142
24
BG2144
18
15
AGK1GGX
2 3
APL1258UM
2
BG2146
6
5/8TBE&J
BASE
INNER
ANCHOR
CB5G
OUTER
ANCHOR
AB4 AB2
400 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G90R400
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
40 1 1 8
3 3
3/16EHS
2075
5/16THH
18
1/4EHS
4700
3/8THH
24
142265
1600
7/16THH
6
BG2142
18
BG2144
24
9
AGK1GGX
2
APL1258UM
2
BG2146
6
1/2TBE&J
BASE
INNER
ANCHOR
CB5G
OUTER
ANCHOR
AB4 AB2
TBSAFETY
6
1/2TBE&J
9
TBSAFETY
6
GAC5655TOP GAC3455TOP
GAC5655TOP GAC3455TOP
3
3
GAC5655TOP GAC3455TOP
3
TBSAFETY
6
15
5/8TBE&J
CPC1/1.25
3
CPC1/1.25
3
CPC1/1.25
3
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
108
2011 ROHN PRODUCTS LLC
P/N: 55G110R120
120 TOWER
115
24.8 19.6 OR
150
96
3/16EHS
(399#)
123
77
38 103
1/4EHS
(665#)
P/N: 55G110R130
130 TOWER
125
24.2 19.2 OR
163
104
3/16EHS
(399#)
133
83
42 112
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
10 1 1 3
600 400 12 6 12
3 1 3
100 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R100
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
P/N: 55G110R100
100 TOWER
95
26.1 20.4 OR
124
80
3/16EHS
(399#)
102
63
33 87
1/4EHS
(665#)
P/N: 55G110R110
110 TOWER
105
25.4 19.9 OR
137
88
3/16EHS
(399#)
114
72
35 95
1/4EHS
(665#)
P/N: 55G110R140
140 TOWER
135
23.6 18.9 OR
175
112
151
101
34 117
67
131
3/16EHS
(399#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
11 1 1 3
675 450 12 6 12
3 1 3
110 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R110
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
12 1 1 3
725 500 12 6 12
3 1 3
120 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R120
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
13 1 1 3
800 525 12 6 12
3 1 3
130 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R130
FDNS
BASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
14 1 1 4
1275 575 18 6 18
3 1 3
140 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R140
FDNS
BASE ANCHOR
3/8THH
6 12
1/2TBE&J
3
TBSAFETY
3
CB1G AB2
CB1G AB2
CB2G AB2
CB2G AB2
CB2G AB2
19.2
18.6
18.2
17.8
17.2
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
S TA NDA R D DE S I GN - 5 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
109
2011 ROHN PRODUCTS LLC
P/N: 55G110R150
150 TOWER
145
23.2 18.7 OR
188
120
161
108
36 125
72
140
3/16EHS
(399#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
15 1 1 4
1375 600 18 6 18
3 1 3
150 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R150
FDNS
BASE ANCHOR
3/8THH
6 12
5/8TBE&J
3
TBSAFETY
3
P/N: 55G110R180
180 TOWER
175
22.0 18.0 OR
227
144
202
142
35
105
178
3/16EHS
(399#)
161
148
72
1/4EHS
(665#)
P/N: 55G110R160
160 TOWER
155
22.8 18.4 OR
201
128
173
116
39 134
78
150
3/16EHS
(399#)
5/16EHS
(1,120#)
P/N: 55G110R170
170 TOWER
165
22.4 18.2 OR
214
136
184
124
41 142
83
159
3/16EHS
(399#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
17 1 1 4
975 1275 12 12 12
3 1 3
170 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R170
FDNS
BASE ANCHOR
3/8THH
12 12
5/8TBE&J
3
TBSAFETY
3
P/N: 55G110R190
190 TOWER
185
21.7 17.8 OR
239
152
212
148
37
111
188
3/16EHS
(399#)
169
156
74
5/16EHS
(1,120#)
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
16 1 1 4
1475 650 18 6 18
3 1 3
160 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R160
FDNS
BASE ANCHOR
7/16THH
6 12
5/8TBE&J
3
TBSAFETY
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
18 1 1 5
1550 1375 18 12 18
3 1 3
180 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R180
FDNS
BASE ANCHOR
3/8THH
12 15
5/8TBE&J
3
TBSAFETY
3
190 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G110R190
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
19 1 1 5
3 3
FDNS
BASE ANCHOR
3/16EHS
1650
5/16THH
18
1/4EHS
675
3/8THH
6
142265
775
7/16THH
6
BG2142
18
5/8TBE&J
15
BG2144
6
AGK1GGX
1
GAC5655TOP
3
BG2146
6
TBSAFETY
3
CB2G AB3
CB2G AB3
CB2G AB3
CB3G AB3
CB3G AB3
15.6
15.8
16.2
16.4
16.8
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC1/1.25 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
110
2011 ROHN PRODUCTS LLC
P/N: 55G110R200
200 TOWER
195
21.4 17.6 OR
252
160
223
156
39
117
198
3/16EHS
(399#)
178
165
78
5/16EHS
(1,120#)
1/4EHS
(665#)
200 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G110R200
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
20 1 1 5
3 3
FDNS
BASE ANCHOR
3/16EHS
1750
5/16THH
18
1/4EHS
725
3/8THH
6
142265
825
7/16THH
6
BG2142
18
BG2144
6
AGK1GGX
1
GAC5655TOP
3
BG2146
6
5/8TBE&J
15
TBSAFETY
3
220 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G110R220
P/N: 55G110R220
220 TOWER
215
20.8 17.2 OR
278
176
5/16EHS
(1,120#)
182
36
145
112
70
94
3/16EHS
(399#)
60
73
209
228
253
1/4EHS
(665#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
22 1 1 6
3 3
3/16EHS
1925
5/16THH
24
1/4EHS
825
3/8THH
6
142265
900
7/16THH
6
BG2142
24
BG2144
6
AGK1GGX
2
GAC5655TOP
3
BG2146
6
1/2TBE&J
6
TBSAFETY
6
5/8TBE&J
12
3
P/N: 55G110R240
240 TOWER
235
20.3 16.9 OR
303
192
5/16EHS
(1,120#)
201
33
167
133
3/16EHS
(399#)
80
66
234
254
278
87
104
127
99
240 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G110R240
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
24 1 1 7
3
3/16EHS
1775
5/16THH
24
1/4EHS
1700
3/8THH
12
142265
975
7/16THH
6
BG2142
24
BG2144
12
AGK1GGX
2 3
BG2146
6
1/2TBE&J
9
TBSAFETY
6
5/8TBE&J
12
3
P/N: 55G110R260
260 TOWER
255
19.8 16.6 OR
329
208
5/16EHS
(1,120#)
219
38
183
147
3/16EHS
(399#)
88
75
255
277
302
96
116
142
111
1/4EHS
(665#)
1/4EHS
(665#)
260 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G110R260
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
26 1 1 7
3 3
3/16EHS
1500
5/16THH
18
1/4EHS
2300
3/8THH
18
142265
1050
7/16THH
6
BG2142
18
BG2144
18
AGK1GGX
2 3
BG2146
6
1/2TBE&J
9
TBSAFETY
6
5/8TBE&J
12
3
CB3G AB3
13.2
12.8
12.4
12.0
BASE
INNER
ANCHOR
CB4G
OUTER
ANCHOR
AB3 AB2
BASE
INNER
ANCHOR
CB4G
OUTER
ANCHOR
AB3 AB2
BASE
INNER
ANCHOR
CB5G
OUTER
ANCHOR
AB3 AB2
CPC1/1.25
CPC.5/.75
CPC.5/.75
CPC.5/.75
GAC3455TOP
GAC5655TOP GAC3455TOP
GAC5655TOP GAC3455TOP
3
CPC1/1.25
3
CPC1/1.25
3
3
CPC1/1.25
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
111
2011 ROHN PRODUCTS LLC
P/N: 55G110R280
280 TOWER
275
19.4 16.4 OR
355
224
5/16EHS
(1,120#)
241
35
173
139
3/16EHS
(399#)
84
71
264
305
91
110
134
105
283
329 207
1/4EHS
(665#)
280 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G110R280
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
28 1 1 8
3 3
3/16EHS
2825
5/16THH
30
1/4EHS
2025
3/8THH
12
142265
1150
7/16THH
6
BG2142
30
1/2TBE&J
9
BG2144
12
AGK1GGX
2 3
BG2146
6
TBSAFETY
6
5/8TBE&J
15
3
P/N: 55G110R300
300 TOWER
295
19.0 16.1 OR
380
240
5/16EHS
(1,120#)
259
41
187
151
3/16EHS
(399#)
100
79
284
328
108
127
152
115
304
353 223
1/4EHS
(665#)
300 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G110R300
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
30 1 1 8
3 3
3/16EHS
1675
5/16THH
18
1/4EHS
2500
3/8THH
18
142265
2350
7/16THH
12
BG2142
18
1/2TBE&J
9
BG2144
18
AGK1GGX
2 3
BG2146
12
TBSAFETY
6
5/8TBE&J
15
3
11.6
BASE
INNER
ANCHOR
CB5G
OUTER
ANCHOR
AB4 AB2
BASE
INNER
ANCHOR
CB5G
OUTER
ANCHOR
AB4 AB2
11.2
CPC.5/.75
CPC.5/.75
GAC5655TOP GAC3455TOP
GAC5655TOP GAC3455TOP
3
CPC1/1.25
3
CPC1/1.25 3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
112
2011 ROHN PRODUCTS LLC
P/N: 55G130R100
100 TOWER
95
18.7 14.6 OR
124
80
3/16EHS
(399#)
102
63
33 87
1/4EHS
(665#)
100 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G130R100
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
10 1 1 3
3 3
FDNS
BASE ANCHOR
3/16EHS
300
5/16THH
6
1/4EHS
325
3/8THH
6
142265
400
7/16THH
6
BG2142
6
1/2TBE&J
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
3
5/16EHS
(1120#)
P/N: 55G130R110
110 TOWER
105
18.2 14.2 OR
137
88
3/16EHS
(399#)
114
72
35 95
1/4EHS
(665#)
110 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G130R110
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
11 1 1 3
3 3
FDNS
BASE ANCHOR
3/16EHS
325
5/16THH
6
1/4EHS
375
3/8THH
6
142265
450
7/16THH
6
BG2142
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
9
GAC5655TOP
3
5/16EHS
(1120#)
P/N: 55G130R120
120 TOWER
115
17.7 14.0 OR
150
96
3/16EHS
(399#)
123
77
38 103
1/4EHS
(665#)
120 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G130R120
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
12 1 1 3
3 3
FDNS
BASE ANCHOR
3/16EHS
350
5/16THH
6
1/4EHS
400
3/8THH
6
142265
500
7/16THH
6
BG2142
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
9
GAC5655TOP
3
5/16EHS
(1120#)
P/N: 55G130R130
130 TOWER
125
17.3 13.8 OR
163
104
133
83
42 112
1/4EHS
(665#)
130 ROHN 55G
All parts shown in
table are included
when ordering
Part No: 55G130R130
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
13 1 1 3
3 3
FDNS
BASE ANCHOR
1/4EHS
800
3/8THH
12
142265
525
7/16THH
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
9
GAC5655TOP
3
5/16EHS
(1120#)
CB2G AB2
CB2G AB3
CB2G AB3
CB2G AB3
18.0
16.0
14.0
12.0
GAC3455TOP
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC.5/.75
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
S TA NDA R D DE S I GN - 5 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
113
2011 ROHN PRODUCTS LLC
140 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G130R140
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
14 1 1 4
3 3
FDNS
BASE ANCHOR
3/16EHS
375
5/16THH
6
1/4EHS
900
3/8THH
12
142265
575
7/16THH
6
BG2142
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R140
140 TOWER
135
16.9 13.6 OR
175
112
151
101
34 117
67
131
3/16EHS
(399#)
1/4EHS
(665#)
150 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G130R150
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
15 1 1 4
3 3
FDNS
BASE ANCHOR
3/16EHS
400
5/16THH
6
1/4EHS
975
3/8THH
12
142265
600
7/16THH
6
BG2142
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R150
150 TOWER
145
16.6 13.4 OR
188
120
161
108
36 125
72
140
3/16EHS
(399#)
1/4EHS
(665#)
160 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G130R160
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
16 1 1 4
3 3
FDNS
BASE ANCHOR
3/16EHS
450
5/16THH
6
1/4EHS
1050
3/8THH
12
142265
650
7/16THH
6
BG2142
6
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
12
GAC5655TOP
3
P/N: 55G130R160
160 TOWER
155
16.3 13.2 OR
201
128
173
116
39 134
78
150
3/16EHS
(399#)
1/4EHS
(665#)
170 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G130R170
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
17 1 1 4
3 3
FDNS
BASE ANCHOR
3/16EHS
475
5/16THH
6
1/4EHS
1100
3/8THH
12
142265
700
7/16THH
6
BG2142
6
3/4TBE&J
12
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5755TOP
3
5/16EHS
(1120#)
5/16EHS
(1120#)
5/16EHS
(1120#)
P/N: 55G130R170
170 TOWER
165
16.0 13.0 OR
214
136
184
124
41 142
83
159
3/16EHS
(399#)
1/4EHS
(665#)
5/16EHS
(1120#)
CB3G AB3
CB3G AB3
CB3G AB3
CB3G AB4
11.0
10.0
9.8
9.6
CPC1.5/2
CPC1/1.25
CPC1/1.25
CPC1/1.25 3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
S TA NDA R D DE S I GN - 5 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
114
2011 ROHN PRODUCTS LLC
180 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G130R180
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
18 1 1 5
3 3
FDNS
BASE ANCHOR
3/16EHS
1000
5/16THH
12
1/4EHS
1225
3/8THH
12
142265
725
7/16THH
6
BG2142
12
3/4TBE&J
15
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5755TOP
3
P/N: 55G130R180
180 TOWER
175
15.8 12.9 OR
227
144
202
142
35
105
178
3/16EHS
(399#) 161
148
72
5/16EHS
(1120#)
1/4EHS
(665#)
P/N: 55G130R190
190 TOWER
185
15.5 12.7 OR
239
152
215
152
41
115
191
173
157
82
5/16EHS
(1120#)
1/4EHS
(665#)
190 ROHN 55G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 55G130R190
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
19 1 1 5
3 3
FDNS
BASE ANCHOR
1/4EHS
2350
3/8THH
24
142265
775
7/16THH
6
3/4TBE&J
15
BG2144
24
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5755TOP
3
CB3G AB4
CB4G AB4
9.0
9.2
CPC1.5/2
CPC1.5/2
3/4x12PP
1
3/4x12PP
1
G
GUY E D T OWE R S - 5 5 G
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
BEARING PLATE
BPL55G
CONVERTS STANDARD SECTION TO A
TOP SECTION. HOLE PATTERN FITS
TB3 (2 O.D.) AND TB4 (3 O.D.) THRUST
BEARING.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
115
2011 ROHN PRODUCTS LLC
ACCESSORY SHELF
AS455G
FOR MOUNTING MANY POPULAR
ROTORS. FIELD DRILLING MAY BE
NECESSARY FOR SOME ROTORS.
FACE MOUNT
DM55G2 - 2 3/8 O.D. 5 LONG
DM554 - 4 1/2 O.D. 5 LONG
SIDE ARM BRACKET
SA253UA
MOUNTING TUBE PROVIDED IS 3 LONG,
2 - 1/4 O.D.
TOP MOUNT
55TDMKD - NO MAST
55TDM2S3KD - 2 3/8 O.D. MAST
55TDM25S3KD - 2 7/8 O.D. MAST
55TDM3S3KD - 3 1/2 O.D. MAST
55TDM35S3KD - 4 O.D. MAST
55TDM4S3KD - 4 1/2 O.D. MAST
MOUNTING TUBE PROVIDED IS 7.
TAPERED BASE*
55TG - STANDARD
55TGIA - USE WITH A4197L
BASE INSULATOR
55TGIAA - USE WITH
A4722B BASE INSULATOR
INSULATOR AND PIER PIN
MUST BE ORDERED
SEPARATELY.
TOP PLATE
APL55G
FOR MOUNTING BEACON OR
LIGHTNING ROD.
LIGHTNING ROD
LRCL
5 COPPER CLAD, MOUNTS TO APL55G.
PIER PIN
3/4X12PP
FOR USE WITH BPC55G
EMBEDDED IN CONCRETE.
PIER PIN MUST BE ORDERED
SEPARATELY, UNLESS BEING
PURCHASED AS PART OF
A COMPLETE TOWER KIT.
5 SHORT BASE
SB55G
FOR EMBEDMENT IN CONCRETE.
FLAT ROOF MOUNT
FR55G*
BOLTS DIRECTLY TO FLAT ROOF SURFACE.
CONCRETE BASE PLATE
BPC55G*
FOR USE WITH 3/4X12PP PIER PIN
EMBEDDED IN CONCRETE.
CONCRETE BASE PLATE IS TO BE
USED FOR BRACKETED AND
GUYED APPLICATIONS ONLY.
Adjustable
2.5 - 3.0
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SYSTEM
ORDERING INFORMATION
TOWER
HEIGHT
50
100
150
200
250
300
350
400
PART
NUMBER
TT0504555
TT1004555
TT1504555
TT2004555
TT2504555
TT3004555
TT3504555
TT4004555
SAFETY CABLE
SLIDER WITH CARABINEER
TT-WG-500-W/SMC
G
GUY E D T OWE R S - 5 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
PA R T S & ACC E S S OR I E S
116
2011 ROHN PRODUCTS LLC
SAFETY RING
SR55
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
WORK PLATFORM
WP55G
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
SAFETY CABLE SLIDER AND CLIMBING
HARNESS MUST BE ORDERED SEPARATELY.
HEAVY DUTY UNIVERSAL
HOUSE BRACKET
HBUTVRO
ADJUSTABLE TO POSITION TOWER
18 - 36 FROM WALL.
THRUST BEARING
TB3 - SUPPORTS UP TO 2 O.D. MAST.
TB4 - SUPPORTS UP TO 3 O.D. MAST.
MOUNTS TO BPL55G.
GUY BRACKET
GA55GD
MOUNTS TO TOWER AT ANY
HORIZONTAL BRACE.
TORQUE ARM STABILIZER
ASSEMBLY
TA55
ANTI-TWIST DEVICE LOCATED IN THE
AREA OF ANTENNAS. PROVIDES SIX-WAY
GUYING. BOLTS TO TOWER AT ANY
SECTION JOINT. ATTACHED WITH
JOINT BOLTS. MUST BE INSTALLED AS
SECTIONS ARE JOINED TOGETHER.
TORQUE BAR
TB55D
OPTIONAL, FOR USE WITH GA55GD.
REQUIRES (1) 3/8 SHACKLE
FOR EACH BAR.
ANTI-CLIMB PANELS
455ACL3
THREE ANTI-CLIMB PANELS BOLT
TO STANDARD TOWER SECTION.
G
GUY E D T OWE R S - 5 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
117
2011 ROHN PRODUCTS LLC
REV G
ANCHOR GROUNDING
AGK1GGX
REV G
BASE GROUNDING
BGK2GGX
A NC HOR I NF OR MAT I ON
3/8
2
12
3/4 P/N STAMPED HERE
GAC3455TOP
1/2
2 1/2
12
120
1 1/4 P/N STAMPED HERE
GAC5655TOP
81
3/4
3
12
168
1 7/16 P/N STAMPED HERE
GAC5755TOP
11/16
13/16
15/16
4 x 4 x 3/8 angle
5 x 5 x 3/8 angle
C
L
of hole to edge
of plate = 1 1/4
C
L
of hole to edge
of plate = 1
C
L
of hole to edge
of plate = 1 1/4
5 x 5 x 3/8 angle
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp
6 Min.
Attach to leg with
supplied leg clamp
Ground Wire
6 Min.
Ground Rod Clamp
Ground Rod,
3 provided (to be installed
at 120 separation at 20 spacing.
o
All around stirrups
equally spaced 12
O.C. anchored with 90
hooks around a
horizontal bar
Top and bottom
horizontal bars
equally spaced
C
B
A
Ground Line
D
Anchor rod
o
Additional bar at
center-line each
side, when required
S TA NDA R D A NC HOR B L OC K S
Block
AB2
AB3
AB4
AB5
AB6
A
4 - 0
6 - 0
6 - 0
8 - 0
8 - 0
Concrete Vol.
(Cu. Yds.)
1.33 Per Block
4.0 Total for 3
1.0 Per Block
3.0 Total for 3
2.0 Per Block
6.0 Total for 3
2.22 Per Block
6.7 Total for 3
2.96 Per Block
8.9 Total for 3
B
1 - 6
1 - 6
1 - 6
2 - 0
2 - 0
C
4 - 0
3 - 0
4 - 0
3 - 0
4 - 0
Horizontal Bars
(Qty. & Size)
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer
(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer
(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer
(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
D
6 - 0
6 - 0
9 - 0
10 - 0
10 - 0
Anchor Dimensions (in.)
Stirrup Size
& Spacing
#3 @ 12 O.C.
#3 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
118
2011 ROHN PRODUCTS LLC
Refer to page 119 for anchor rod installation angles.
G
GUY E D T OWE R S - 5 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
119
2011 ROHN PRODUCTS LLC
A NC HOR R OD I NS TA L L AT I ON A NGL E S
120
o
Ground Line
Rod Angle
(in degrees)
Tower
Height
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
360
380
400
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Inner
Rod
Angle
42
42
40
40
40
39
39
38
38
40
40
38
37
43
42
39
40
40
40
40
38
55G | 90MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
42
42
43
43
42
42
42
42
Tower
Height
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Inner
Rod
Angle
41
40
40
40
38
38
39
38
38
38
38
42
40
41
40
39
55G | 110MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
43
44
44
43
43
Tower
Height
100
110
120
130
140
150
160
170
180
190
Rod
Number
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
Rod
Angle
41
40
40
40
40
40
40
38
38
37
55G | 130MPH
Tower Plan Anchor Rod Angle
S TA NDA R D B A S E P I E R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 5 5 G
120
2011 ROHN PRODUCTS LLC
Base
CB1G*
CB2G
CB3G
CB4G
CB5G
A
2 - 6
3 - 0
3 - 6
4 - 0
2 - 0
Vertical Bars
(No. & Size)
(8) #7
(10) #7
(12) #7
(12) #8
(8) #6
Concrete Vol.
(Cu. Yds.)
Round Pier
1.0
1.2
1.6
2.1
1.1
B
2 - 6
3 - 0
3 - 6
4 - 0
4 - 0
C
N/A
N/A
N/A
N/A
1 - 0
Horiz. Bars
in Pad
(No. & Size)
NONE
NONE
NONE
NONE
(5) #5
(Total of 10)
D
4 - 0
4 - 0
4 - 0
4 - 0
4 - 0
E
N/A
N/A
N/A
N/A
3 - 3
F
N/A
N/A
N/A
N/A
1 - 3
Alternate
Square
Pier
PLAN VIEW
A
B
No. 4 Circular ties, 3 O.C.
with 24 laps
Vertical bars equally spaced
(2) No. 4 Circular ties, 2-1/2 O.C.
with 2 cover with 24 laps
4 Projection
6
No. 4 Circular ties, 3 Max. O.C.
with 24 laps
Vertical re-bars equally spaced
with 90 hooks at bottom (for CB5G)
Roughen construction joint to
a full amplitude of 1/4
Foundation Pad
Horizontal reinforcing
steel bars equally spaced
each way
C
E
D
F
ELEVATION VIEW
B
Pier Pin
Grade
* Square pier option must be used for CB1G.
A
C
L
L
C
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
121
2011 ROHN PRODUCTS LLC
NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D 6 5 G GUY E D T OWE R
122
2011 ROHN PRODUCTS LLC
The first. The original.
ROHN 65G
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 142 for ordering information.
REV. G
includes
REV. F&
GENERAL USE
The 65G is designed to provide excellent rigidity
and strength in applications up to 500. This
high strength design covers a wide variety of
communication uses. The 65G is completely
pre-fabricated in welded sections, allowing for
quick and convenient installation.
FEATURES
Completely hot-dip galvanized after fabrication
Built on a 24 1/4 equilateral triangle design
High strength tubular legs joined by Zig-Zag

cross members
Each section contains all required nuts and bolts
shipped with section
Continuous solid round steel bracing
65G
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all
engineering and warranty data supplied by ROHN. Materials used by others are
not the same quality and have not been tested or engineered by ROHN. Mixing
ROHN tower sections with non-ROHN products may cause tower failure or injury.
CAUTION
1.90 O.D.
(0.145 Wall)
STANDARD SECTION
65G - 10 Section
6520G - 20 Section
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D 6 5 G GUY E D T OWE R
S E C T I ONS
123

5/8 O.D. Solid Bracing


TAPERED BASE
65TGH - 10 Section
5/8 O.D.
Solid Bracing
2011 ROHN PRODUCTS LLC
PARTS & ACCESSORIES PAGES 141-142
GROUNDING INFORMATION PAGE 143
FOUNDATION INFORMATION PAGES 143-146
QUICK REFERENCE
21
14
24 1/4
Optional double braced sections
are available upon request.
Optional Waveguide
Brackets (KY2041A)
1.90 O.D.
(0.145 Wall)
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
EPA (SQ. FT.), Revision F
P/N 65G90R100

122
92
92
45
80
3/16 EHS
(399#)
60.8
68.0
78.1
P/N 65G90R100

Tower Model
Windspeed (Rev. G) ROHN Tower
Tower Height (ft.)
EPA= Effective Projected Area
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
B UY E R S GUI DE
S TA NDA R D DE S I GNS - 6 5 G
9 0 MP H R E V. G [ 3 S E C ON D G U S T ]
7 0 MP H R E V. F [ FA S T E S T MI L E ]
124
2011 ROHN PRODUCTS LLC
5/16 EHS
(1,120#)
Guy Initial Tension
This document is to serve as a guide for sizing and purchasing the 65G tower. Tower and foundation installations should
be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites
located on unusual terrain.
3. Designs assume two 7/8 diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60 Fahrenheit.
6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material.
5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 143-146.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
Design Criteria
P/N: 65G90R130
130 TOWER
120
72.3 57.3 OR
159
104
5/16EHS
(1,120#)
120
60
3/16EHS
(399#)
63.4
P/N: 65G90R120
120 TOWER
112
73.9 58.5 OR
148
96
5/16EHS
(1,120#)
111
55
3/16EHS
(399#)
64.8
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
125
2011 ROHN PRODUCTS LLC
P/N: 65G90R100
100 TOWER
92
78.0 60.8 OR
122
80
5/16EHS
(1,120#)
92
45
3/16EHS
(399#)
P/N: 65G90R110
110 TOWER
100
75.8 59.6 OR
133
88
5/16EHS
(1,120#)
102
52
3/16EHS
(399#)
P/N: 65G90R140
140 TOWER
129
70.7 56.6 OR
171
112
3/16EHS
(399#)
141
86
43 120
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G GA65GD
142265 3/16EHS BG2142 BG2146 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
1 1 4 2
400 300 6 6 6
3 1 3
100 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R100
FDNS
BASE ANCHOR
7/16THH
6 3
1/2TBE&J
3
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142265 3/16EHSBG2142BG21465/16THH
AGK1GGX BGK2GGX
1 5 1 2
425 325 6 6 6
3 1 3
110 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R110
FDNS
BASE ANCHOR
7/16THH
6 3
1/2TBE&J
3
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G GA65GD
142265 3/16EHS BG2142BG2146 5/16THH
AGK1GGX BGK2GGX
1 1 5 2
475 375 6 6 6
3 1 3
120 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R120
FDNS
BASE ANCHOR
7/16THH
6 3
1/2TBE&J
3
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G GA65GD APL4HA
142265 3/16EHS BG2142BG21465/16THH
AGK1GGX BGK2GGX
1 6 2 1
525 400 6 6 6
3 1 3
130 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R130
FDNS
BASE ANCHOR
7/16THH
6 3
1/2TBE&J
3
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
142265 3/16EHS BG2142BG21465/16THH
AGK1GGX BGK2GGX
1 1 6 1
550 850 12 6 12
3 1 3
140 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R140
FDNS
BASE ANCHOR
7/16THH
6 3
1/2TBE&J
6
5/8TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB2
68.0
66.2
62.2
APL4HA
1
GAC3455TOP
APL4HA
1
GAC3455TOP
GAC3455TOP
GA65GD
3
GAC3455TOP
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
P/N: 65G90R180
180 TOWER
168
65.6 53.7 OR
221
144
3/16EHS
(399#)
182
112
56 155
5/16EHS
(1,120#)
1/4EHS
(665#)
P/N: 65G90R170
170 TOWER
159
66.7 54.3 OR
209
136
3/16EHS
(399#)
172
106
53 146
5/16EHS
(1,120#)
59.0
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
126
2011 ROHN PRODUCTS LLC
P/N: 65G90R150
150 TOWER
138
69.4 55.8 OR
183
120
3/16EHS
(399#)
151
92
46 129
5/16EHS
(1,120#)
P/N: 65G90R160
160 TOWER
152
67.8 55.0 OR
199
128
3/16EHS
(399#)
162
100
52 138
5/16EHS
(1,120#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142265 3/16EHS BG2142BG2146 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
1 7 1 3
600 900 12 6 12
3 1 3
150 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R150
FDNS
BASE ANCHOR
7/16THH
6 3
1/2TBE&J
6
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
142265 3/16EHS BG2142BG2146 5/16THH
AGK1GGX BGK2GGX
1 1 7 1
650 975 12 6 12
3 1 3
160 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R160
FDNS
BASE ANCHOR
7/16THH
6 9
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
1422653/16EHS BG2142BG21465/16THH
GAC5655TOP AGK1GGX BGK2GGX
1 8 1 3
675 1025 12 6 12
3 1 3
170 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R170
FDNS
BASE ANCHOR
7/16THH
6 9
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2146 5/8TBE&J 7/16THH
1 1 8 1
6 9 6
180 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G90R180
FDNS
BASE ANCHOR
3/8THH
6
5/16THH
6
CPC.5/.75
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
CB2G AB2
CB2G AB3
CB3G AB3
CB3G AB3
61.0
60.0
58.2
GA65GD
3
GAC5655TOP
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
725 600 500
BG2142
6
BG2144
6
GA65GD
3
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
GAC5655TOP BGK2GGX CPC1/1.25
1 9 1 3
6 3 3
142265
750
BG2146
6
1/4EHS
625
5/8TBE&J
9
3/16EHS
525
7/16THH
6
BG2142
6
3/8THH
6
BG2144
6
5/16THH
6
AGK1GGX
1
TBSAFETY
3
BASE
INNER
ANCHOR
CB3G AB3
P/N: 65G90R240
240 TOWER
232
60.6 50.5 OR
301
192
258
173
58 201
116
224
3/16EHS
(399#)
1/4EHS
(665#)
5/16EHS
(1,120#)
P/N: 65G90R220
220 TOWER
208
62.1 51.4 OR
272
176
235
156
52 184
104
204
3/16EHS
(399#)
1/4EHS
(665#)
5/16EHS
(1,120#)
P/N: 65G90R200
200 TOWER
186
63.8 52.5 OR
245
160
3/16EHS
(399#)
202
124
62 172
5/16EHS
(1,120#)
1/4EHS
(665#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
127
2011 ROHN PRODUCTS LLC
200 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R200
220 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R220
240 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R240
54.4
53.0
51.6
P/N: 65G90R190
190 TOWER
180
64.8 53.1 OR
236
152
3/16EHS
(399#)
194
120
60 163
5/16EHS
(1,120#)
1/4EHS
(665#)
190 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R190
57.2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2146 5/8TBE&J 7/16THH
1 1 9 1
6 9 6
FDNS
BASE ANCHOR
3/8THH
6
5/16THH
6
CB3G AB3
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
800 650 550
BG2142
6
BG2144
6
GA65GD
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2146 5/8TBE&J 7/16THH
1 1 10 1
6 12 6
FDNS
BASE ANCHOR
3/8THH
6
5/16THH
12
CB3G AB3
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
875 750 1250
BG2142
12
BG2144
6
GA65GD
4
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2146 5/8TBE&J 7/16THH
1 1 11 1
6 12 6
FDNS
BASE ANCHOR
3/8THH
6
5/16THH
12
CB3G AB3
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
975 825 1375
BG2142
12
BG2144
6
GA65GD
4
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
P/N: 65G90R300
300 TOWER
292
56.8 48.2 OR
378
240
334
232
58
174
296
3/16EHS
(399#)
267
247
116
3/8EHS
(1,540#)
P/N: 65G90R280
280 TOWER
272
58.0 48.9 OR
352
224
311
216
54
162
276
1/4EHS
(665#)
249
230
108
3/16EHS
(399#)
3/8EHS
(1,540#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
128
2011 ROHN PRODUCTS LLC
280 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R280
300 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R300
49.4
48.4
1/4EHS
(665#)
P/N: 65G90R260
260 TOWER
248
59.2 49.7 OR
324
208
279
186
62 217
124
242
3/16EHS
(399#)
1/4EHS
(665#)
3/8EHS
(1,540#)
260 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R260
50.4
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2147 5/8TBE&J 1/2THH
1 1 12 1
6 12 6
FDNS
BASE ANCHOR
3/8THH
12
5/16THH
6
CB4G AB4
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
1050 1675 700
BG2142
6
BG2144
12
GA65GD
4
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2147 5/8TBE&J 1/2THH
1 1 13 1
6 15 6
FDNS
BASE ANCHOR
3/8THH
12
5/16THH
12
CB4G AB4
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
1125 1875 1550
BG2142
12
BG2144
12
GA65GD
5
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 14 1
12 6 6
FDNS
BASE ANCHOR
5/8TBE&J
15
1/2THH
6
CB4G AB4
7/16THH 3/8THH 5/16THH
6 12 6
142261 142265 1/4EHS
1225 1075 1800
3/16EHS
800
BG2142
6
GA65GD
5
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
5/16EHS
(1,120#)
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
P/N: 65G90R360
360 TOWER
352
53.9 46.4 OR
455
288
5/16EHS
(1,120#)
292
59
234
176
111
151
94
118
338
371
410
1/4EHS
(665#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
129
2011 ROHN PRODUCTS LLC
360 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R360
45.8
3/8EHS
(1,540#)
P/N: 65G90R340
340 TOWER
332
54.8 46.9 OR
429
272
3/8EHS
(1,540#)
275
55
220
165
104
142
1/4EHS
(665#)
88
112
318
350
387
P/N: 65G90R320
320 TOWER
312
55.8 47.5 OR
404
256
356
248
62
186
316
3/16EHS
(399#)
284
263
124
3/8EHS
(1,540#)
320 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R320
340 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R340
47.6
46.6
1/4EHS
(665#)
5/16EHS
(1,120#)
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 15 1
12 6 6
FDNS
BASE ANCHOR
5/8TBE&J
15
1/2THH
6
CB5G AB4
7/16THH 3/8THH 5/16THH
6 12 6
142261 142265 1/4EHS
1300 1150 1925
3/16EHS
850
BG2142
6
GA65GD
5
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 16 1
18 6 6
BASE
5/8TBE&J
12
1/2TBE&J
6
CB5G AB2
1/2THH 7/16THH 3/8THH
6 6 18
142261 142265 1/4EHS
1375 1250 2600
3/16EHS
350
BG2142
6
GA65GD
6
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC.5/.75
3
3
INNER
ANCHOR
OUTER
ANCHOR
AB4
5/16THH
6
TBSAFETY
6
GAC3455TOP
CPC1/1.25
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 17 1
24 6 6
BASE
1/2THH
6
7/16THH
6
CB6G AB2
142261 142265 1/4EHS
1450 1325 3100
5/8TBE&J
12
1/2TBE&J
6
GA65GD
6
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC.5/.75
3 3
INNER
ANCHOR
OUTER
ANCHOR
AB4
APL1258UM
2
GAC3455TOP
CPC1/1.25
3
3/8THH
24
TBSAFETY
6
5/16EHS
(1,120#)
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
130
2011 ROHN PRODUCTS LLC
P/N: 65G90R420
420 TOWER
412
51.6 44.9 OR
532
336
352
59
236
142
118
154
185
227
177
487
294
411
446
5/16EHS
(1,120#)
1/4EHS
(665#)
3/8EHS
(1,540#)
P/N: 65G90R380
380 TOWER
372
53.1 45.8 OR
480
304
5/16EHS
(1,120#)
309
63
248
187
118
160
100
125
357
392
433
1/4EHS
(665#)
3/8EHS
(1,540#)
380 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R380
45.2
P/N: 65G90R400
400 TOWER
392
52.3 45.3 OR
506
320
334
55
222
133
112
144
174
213
166
463
278
389
424
5/16EHS
(1,120#)
1/4EHS
(665#)
3/8EHS
(1,540#)
44.4
400 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R400
43.8
420 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R420
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 18 1
24 6 6
BASE
1/2THH
6
7/16THH
6
CB6G AB2
142261 142265 1/4EHS
1550 1400 3300
5/8TBE&J
12
1/2TBE&J
6
GA65GD
6
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC.5/.75
3 3
INNER
ANCHOR
OUTER
ANCHOR
AB4
APL1258UM
2
GAC3455TOP
CPC1/1.25
3
3/8THH
24
TBSAFETY
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 19 1
30 6 6
BASE
1/2THH
6
7/16THH
6
CB6G AB2
142261 142265 1/4EHS
1625 1475 4300
5/8TBE&J
12
1/2TBE&J
9
GA65GD
7
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC.5/.75
3 3
INNER
ANCHOR
OUTER
ANCHOR
AB4
APL1258UM
2
GAC3455TOP
CPC1/1.25
3
3/8THH
30
TBSAFETY
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 20 1
12 24 6
BASE
1/2THH
6
7/16THH
24
CB6G AB3
142261 142265 1/4EHS
1700 5025 1100
5/8TBE&J
21
GA65GD
7
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
6 2 3 2
INNER
ANCHOR
OUTER
ANCHOR
AB4
APL1258UM
3/8THH
12
CPC1/1.25
TBSAFETY
6
6
15/16x16PP
1
15/16x16PP
1
1
15/16x16PP
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
131
2011 ROHN PRODUCTS LLC
P/N: 65G90R480
480 TOWER
472
49.7 43.6 OR
609
384
413
59
236
142
118
154
185
227
177
564
354
484
5/16EHS
(1,120#)
1/4EHS
(665#)
3/8EHS
(1,540#)
295 522
451
P/N: 65G90R460
460 TOWER
448
50.3 44.0 OR
580
368
392
56
224
134
112
146
175
215
168
538
336
5/16EHS
(1,120#)
1/4EHS
(665#)
3/8EHS
(1,540#)
280
498
431
462
P/N: 65G90R440
440 TOWER
428
50.9 44.4 OR
554
352
368
63
248
150
126
163
196
241
188
509
308
431
468
5/16EHS
(1,120#)
1/4EHS
(665#)
3/8EHS
(1,540#)
440 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R440
460 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R460
480 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R480
43.2
42.6
42.0
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 21 1
12 24 6
BASE
1/2THH
6
7/16THH
24
CB7G AB3
142261 142265 1/4EHS
1775 5275 1150
5/8TBE&J
21
GA65GD
7
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
6 2 3 2
INNER
ANCHOR
OUTER
ANCHOR
AB4
APL1258UM
3/8THH
12
CPC1/1.25
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 22 1
12 30 6
BASE
1/2THH
6
7/16THH
30
CB7G AB3
142261 142265 1/4EHS
1850 6850 1025
3/4TBE&J
15
5/8TBE&J
9
GA65GD
8
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC1/1.25
3 3
INNER
ANCHOR
OUTER
ANCHOR
AB5
APL1258UM
2
GAC5755TOP
CPC1.5/2
3
3/8THH
12
TBSAFETY
6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 23 1
12 30 6
BASE
1/2THH
6
7/16THH
30
CB7G AB3
142261 142265 1/4EHS
1950 7175 1100
3/4TBE&J
15
5/8TBE&J
9
GA65GD
8
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC1/1.25
3 3
INNER
ANCHOR
OUTER
ANCHOR
AB5
APL1258UM
2
GAC5755TOP
CPC1.5/2
3
3/8THH
12
TBSAFETY
6
1
15/16x16PP TBSAFETY
6
15/16x16PP
1
15/16x16PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
9 0 MP H R E V. G , 7 0 MP H R E V. F
132
2011 ROHN PRODUCTS LLC
P/N: 65G90R500
500 TOWER
488
49.1 43.3 OR
631
400
427
61
244
150
122
162
193
237
183
585
366
503
5/16EHS
(1,120#)
1/4EHS
(665#)
3/8EHS
(1,540#)
305
542
469
500 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R500
41.6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2144 BG2146 BG2147
1 1 24 1
12 30 6
BASE
1/2THH
6
7/16THH
30
CB7G AB3
142261 142265 1/4EHS
2025 7450 1150
3/4TBE&J
15
5/8TBE&J
9
GA65GD
8
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 2 3
CPC1/1.25
3 3
INNER
ANCHOR
OUTER
ANCHOR
AB5
APL1258UM
2
GAC5755TOP
CPC1.5/2
3
3/8THH
12
TBSAFETY
6
15/16x16PP
1
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
142265 1/4EHS BG2144 BG2146 7/16THH
GAC5655TOP AGK1GGX BGK2GGX
1 1 5 1
475 375 6 6 6
3 1 3
FDNS
BASE ANCHOR
3/8THH
6 6
5/8TBE&J
CPC1/1.25
3
TBSAFETY
3
AB3
GA65GD
2
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142265 1/4EHS BG2144 BG2146 7/16THH
GAC3455TOP AGK1GGX BGK2GGX
1 5 1 2
425 325 6 6 6
3 1 3
FDNS
BASE ANCHOR
3/8THH
6 3
1/2TBE&J
3
5/8TBE&J
CPC.5/.75
3
TBSAFETY
3
AB2
P/N: 65G110R140
140 TOWER
129
47.2 37.9 OR
171
112
3/16EHS
(399#)
141
86
43 120
1/4EHS
(665#)
5/16EHS
(1,120#)
P/N: 65G110R130
130 TOWER
120
48.4 38.5 OR
159
104
3/8EHS
(1,540#)
120
60
1/4EHS
(665#)
P/N: 65G110R120
120 TOWER
112
49.5 39.2 OR
148
96
5/16EHS
(1,120#)
111
55
1/4EHS
(665#)
P/N: 65G110R110
110 TOWER
100
50.8 39.9 OR
133
88
5/16EHS
(1,120#)
102
52
1/4EHS
(665#)
P/N: 65G110R100
100 TOWER
92
52.2 40.7 OR
122
80
5/16EHS
(1,120#)
92
45
1/4EHS
(665#)
22.2
22.8
S TA NDA R D DE S I GN - 6 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
133
2011 ROHN PRODUCTS LLC
100 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R100
110 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R110
120 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R120
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142261 1/4EHS BG2147 BG2144 1/2THH
AGK1GGX BGK2GGX
1 6 1 2
525 400 6 6 6
3 1 3
130 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R130
FDNS
BASE ANCHOR
3/8THH
6 6
5/8TBE&J
140 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R140
TBSAFETY
3
CPC1/1.25
3
CB2G AB3
24.2
23.6
21.6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
142265 1/4EHS BG2144 BG2146 7/16THH
GAC3455TOP AGK1GGX BGK2GGX
1 1 4 1
400 300 6 6 6
3 1 3
FDNS
BASE ANCHOR
3/8THH
6 3
1/2TBE&J
3
5/8TBE&J
CPC.5/.75
3
TBSAFETY
3
AB2
GA65GD
2
GAC5655TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2146 5/8TBE&J 7/16THH
1 1 6 1
6 9 6
FDNS
BASE ANCHOR
3/8THH
6
5/16THH
6
CB3G AB3
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142265 1/4EHS 3/16EHS
550 450 400
BG2142
6
BG2144
6
GA65GD
3
CB2G
CB2G
CB2G
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
P/N: 65G110R180
180 TOWER
168
44.1 35.9 OR
221
144
1/4EHS
(665#)
182
112
56 155
3/8EHS
(1,540#)
P/N: 65G110R170
170 TOWER
159
44.8 36.4 OR
209
136
172
106
53 146
3/8EHS
(1,540#)
1/4EHS
(665#)
P/N: 65G110R160
160 TOWER
152
45.6 36.8 OR
199
128
3/16EHS
(399#)
162
100
52 138
3/8EHS
(1,540#)
1/4EHS
(665#)
P/N: 65G110R150
150 TOWER
138
46.4 37.3 OR
183
120
3/16EHS
(399#)
151
92
46 129
3/8EHS
(1,540#)
1/4EHS
(665#)
20.2
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
134
2011 ROHN PRODUCTS LLC
150 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R150
160 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R160
170 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G110R170
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
142261 1/4EHS BG2144 BG2147 1/2THH
GAC5655TOP AGK1GGX BGK2GGX
1 1 8 1
725 1075 12 6 6
3 1 3
180 ROHN65G
All parts shown in
table are included
when ordering
Part No: 65G110R180
FDNS
BASE ANCHOR
3/8THH
12 9
5/8TBE&J
CPC1/1.25
3
TBSAFETY
3
CB3G AB3
21.2
20.6
19.8
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
GAC5655TOP BGK2GGX CPC1/1.25
1 7 1 3
6 3 3
142261
600
BG2147
6
1/4EHS
500
5/8TBE&J
9
3/16EHS
425
1/2THH
6
BG2142
6
3/8THH
6
BG2144
6
5/16THH
6
AGK1GGX
1
TBSAFETY
3
CB3G AB3
FDNS
BASE ANCHOR
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2147 5/8TBE&J 1/2THH
1 1 7 1
6 9 6
FDNS
BASE ANCHOR
3/8THH
6
5/16THH
6
CB3G AB3
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142261 1/4EHS 3/16EHS
650 525 450
BG2142
6
BG2144
6
GA65GD
3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142261 1/4EHS BG2144 BG2147 1/2THH
GAC5655TOP AGK1GGX BGK2GGX
1 8 1 3
675 1025 12 6 6
3 1 3
FDNS
BASE ANCHOR
3/8THH
12 9
5/8TBE&J
CPC1/1.25
3
TBSAFETY
3
CB3G AB3
GA65GD
3
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
P/N: 65G110R240
240 TOWER
232
40.6 33.8 OR
301
192
258
173
58 201
116
224
1/4EHS
(665#)
5/16EHS
(1,120#)
3/8EHS
(1,540#)
P/N: 65G110R220
220 TOWER
208
41.6 34.4 OR
272
176
235
156
52 184
104
204
1/4EHS
(665#)
5/16EHS
(1,120#)
3/8EHS
(1,540#)
P/N: 65G110R200
200 TOWER
186
42.7 35.1 OR
245
160
1/4EHS
(665#)
202
124
62 172
5/16EHS
(1,120#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
135
2011 ROHN PRODUCTS LLC
200 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R200
220 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R220
240 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R240
17.0
16.4
15.8
P/N: 65G110R190
190 TOWER
180
43.4 35.5 OR
236
152
1/4EHS
(665#)
194
120
60 163
3/8EHS
(1,540#)
5/16EHS
(1,120#)
190 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R190
19.4
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
GAC5655TOP BGK2GGX CPC1/1.25
1 9 1 3
6 3 3
142261
750
BG2147
6
142265
625
5/8TBE&J
9
1/4EHS
525
1/2THH
6
BG2144
6
7/16THH
6
BG2146
6
3/8THH
6
AGK1GGX
1
TBSAFETY
3
CB4G AB4
FDNS
BASE ANCHOR
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2147 5/8TBE&J 1/2THH
1 1 9 1
6 9 6
FDNS
BASE ANCHOR
7/16THH
6
3/8THH
6
CB4G AB4
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142261 142265 1/4EHS
800 650 550
BG2144
6
BG2146
6
GA65GD
3
3/8EHS
(1,540#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2147 5/8TBE&J 1/2THH
1 1 10 1
6 12 6
FDNS
BASE ANCHOR
7/16THH
6
3/8THH
12
CB4G AB4
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142261 142265 1/4EHS
875 750 1250
BG2144
12
BG2146
6
GA65GD
4
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
BG2147 5/8TBE&J 1/2THH
1 1 11 1
6 12 6
FDNS
BASE ANCHOR
7/16THH
6
3/8THH
12
CB4G AB4
ANCHORS &
GROUNDING
INCLUDED
GAC5655TOP AGK1GGX BGK2GGX
3 1 3
CPC1/1.25
3
TBSAFETY
3
142261 142265 1/4EHS
975 825 1375
BG2144
12
BG2146
6
GA65GD
4
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
P/N: 65G110R320
320 TOWER
312
37.3 31.8 OR
404
256
356
248
62
186
316
5/16EHS
(1,120#)
284
263
124
1/4EHS
(665#)
3/8EHS
(1,540#)
P/N: 65G110R300
300 TOWER
292
38.0 32.3 OR
378
240
334
232
58
174
296
267
247
116
1/4EHS
(665#)
5/16EHS
(1,120#)
3/8EHS
(1,540#)
P/N: 65G110R280
280 TOWER
272
38.8 32.7 OR
352
224
311
216
54
162
276
1/4EHS
(665#)
249
230
108
5/16EHS
(1,120#)
3/8EHS
(1,540#)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
S TA NDA R D DE S I GN - 6 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
136
2011 ROHN PRODUCTS LLC
280 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R280
300 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R300
320 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R320
14.8
14.4
14.0
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
BGK2GGX CPC1.5/2
1 1 13 1
6 3
142261
1125
7/16THH
6
142265
1000
3/4TBE&J
15
BG2144
18
3/8THH
18
BG2146
6
1/2THH
6
BG2147
6
1/4EHS
2450
AGK1GGX
1
3
CB5G AB5
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
BGK2GGX CPC1.5/2
1 1 14 1
3 3
142261
1225
BG2147
6
142265
2875
3/4TBE&J
15
1/4EHS
800
1/2THH
6
BG2144
6
7/16THH
18
BG2146
18
3/8THH
6
AGK1GGX
1 3
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
BGK2GGX CPC1.5/2
1 1 15 1
3 3
142261
2425
BG2147
12
142265
1925
3/4TBE&J
15
BG2144
6
1/2THH
12
BG2146
12
7/16THH
12
3/8THH
6
AGK1GGX
1 3
1/4EHS
850
P/N: 65G110R260
260 TOWER
248
39.6 33.2 OR
324
208
279 186
62 217
124
242
1/4EHS
(665#)
3/8EHS
(1,540#)
5/16EHS
(1,120#)
260 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R260
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
GAC5755TOP BGK2GGX CPC1.5/2
1 1 12 1
3 3 3
142261
1050
7/16THH
12
142265
1675
3/4TBE&J
12
1/4EHS
700
3/8THH
6
BG2144
6
BG2146
12
1/2THH
6
BG2147
6
AGK1GGX
1
CB5G AB5
15.2
GA65GD
4
TBSAFETY
3
FDNS
BASE ANCHOR
FDNS
BASE ANCHOR
GA65GD
5
GAC5755TOP TBSAFETY
3
CB5G AB5
FDNS
BASE ANCHOR
GA65GD
5
GAC5755TOP TBSAFETY
3
CB6G AB6
FDNS
BASE ANCHOR
GA65GD
5
GAC5755TOP TBSAFETY
3
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
S TA NDA R D DE S I GN - 6 5 G
1 1 0 MP H R E V. G , 9 0 MP H R E V. F
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
137
2011 ROHN PRODUCTS LLC
P/N: 65G110R340
340 TOWER
332
36.7 31.4 OR
429
272
275
55
220
165
104
142
1/4EHS
(665#)
88
112
318
350
387
5/16EHS
(1,120#)
3/8EHS
(1,540#)
340 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G110R340
13.6
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
GAC5755TOP BGK2GGX
CPC1/1.25
1 1 16 1
3
3 3
142261
2600
3/4TBE&J
12
1/4EHS
350
5/8TBE&J
6
BG2144
6
1/2THH
12
BG2146
18
7/16THH
18
BG2147
12
3/8THH
6
AGK1GGX
2 3
BASE
INNER
ANCHOR
CB7G
OUTER
ANCHOR
AB5 AB3
142265
2600
GA65GD
6
GAC5655TOP
TBSAFETY
6 3
CPC1.5/2 15/16x16PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
138
2011 ROHN PRODUCTS LLC
P/N: 65G130R130
130 TOWER
120
30.1 24.0 OR
159
104
3/8EHS
(1,540#)
120
60
5/16EHS
(1,120#)
11.0
P/N: 65G130R120
120 TOWER
112
30.8 24.4 OR
148
96
3/8EHS
(1,540#)
111
55
5/16EHS
(1,120#)
11.4
S TA NDA R D DE S I GN - 6 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
P/N: 65G130R100
100 TOWER
92
32.5 25.4 OR
122
80
5/16EHS
(1,120#)
92
45
1/4EHS
(665#)
P/N: 65G130R110
110 TOWER
100
31.6 24.8 OR
133
88
3/8EHS
(1,540#)
101
50
1/4EHS
(665#)
P/N: 65G130R140
140 TOWER
129
29.5 23.6 OR
171
112
5/16EHS
(1,120#)
141
86
43 120
3/16EHS
(399#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65GTH 6520G GA65GD
142265 1/4EHS BG2146 BG2144 5/8TBE&J
AGK1GGX BGK2GGX
1 1 4 2
400 300 6 6 6
1 3
100 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G130R100
FDNS
BASE ANCHOR
3/8THH
6 6
7/16THH
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142261 1/4EHS BG2147 BG2144 1/2THH
AGK1GGX BGK2GGX
1 5 1 2
425 325 6 6 6
3 1 3
110 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G130R110
FDNS
BASE ANCHOR
3/8THH
6 6
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65G 65TGH 6520G APL4HA
142261 142265 BG2147 BG2146 7/16THH
AGK1GGX BGK2GGX
1 1 5 1
475 375 6 6 6
3 1 3
120 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G130R120
FDNS
BASE ANCHOR
1/2THH
6 6
5/8TBE&J
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142261 142265 BG2147 BG2146 7/16THH
AGK1GGX BGK2GGX
1 6 1 2
525 400 6 6 6
3 1 3
130 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G130R130
FDNS
BASE ANCHOR
1/2THH
6 6
5/8TBE&J
140 ROHN 65G
All parts shown in
table are included
when ordering
Part No: 65G130R140
CPC1/1.25
3
TBSAFETY
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
CPC1/1.25
3
CB2G AB3
CB2G AB3
CB3G AB3
CB3G AB3
12.4
11.8
10.6
3/8EHS
(1,540#)
APL4HA
1
GAC5655TOP
3
GAC5655TOP
GA65GD
2
GAC5655TOP
GAC5655TOP
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
142261 142265 BG2147 BG2146
BG2142
1/2THH 7/16THH
1 1 6 1
550 450 6 6
6 9 6 6
FDNS
BASE ANCHOR
5/16THH
6
CB3G AB3
GA65GD
3
5/8TBE&J
ANCHORS &
GROUNDING
INCLUDED
AGK1GGX BGK2GGX
3 1 3
TBSAFETY
3
CPC1/1.25
3
GAC5655TOP
3/16EHS
400
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
139
2011 ROHN PRODUCTS LLC
P/N: 65G130R180
180 TOWER
168
27.4 22.4 OR
221
144
182
112
56 155
3/8EHS
(1,540#)
5/16EHS
(1,120#)
P/N: 65G130R170
170 TOWER
159
27.8 22.7 OR
209
136
5/16EHS
(1,120#)
172
106
53 146
1/4EHS
(665#)
9.6
S TA NDA R D DE S I GN - 6 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
P/N: 65G130R150
150 TOWER
138
28.9 23.3 OR
183
120
5/16EHS
(1,120#)
151
92
46 129
3/16EHS
(399#)
P/N: 65G130R160
160 TOWER
152
28.4 22.9 OR
199
128
5/16EHS
(1,120#)
162
100
52 138
1/4EHS
(665#)
150 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G130R150
160 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G130R160
170 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G130R170
180 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G90R180
10.2
9.8
9.4
3/8EHS
(1,540#)
3/8EHS
(1,540#)
3/8EHS
(1,540#)
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65TGH 6520G APL4HA
142261 142265 BG2147 BG2146
BG2142
1/2THH 7/16THH
1 7 1
600 500 6 6
6 9 6 6
FDNS
BASE ANCHOR
5/16THH
6
CB3G AB4
GA65GD
3
5/8TBE&J
ANCHORS &
GROUNDING
INCLUDED
AGK1GGX BGK2GGX
3 1 3
TBSAFETY
3
CPC1/1.25
3
GAC5655TOP
3/16EHS
425
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
142261 142265 BG2147 BG2146
BG2144
1/2THH 7/16THH
1 1 7 1
650 525 6 6
6 9 6 6
FDNS
BASE ANCHOR
3/8THH
6
CB4G AB4
GA65GD
3
5/8TBE&J
ANCHORS &
GROUNDING
INCLUDED
AGK1GGX BGK2GGX
3 1 3
TBSAFETY
3
CPC1/1.25
3
GAC5655TOP
1/4EHS
450
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65TGH 6520G APL4HA
142261 142265 BG2147 BG2146
BG2144
1/2THH 7/16THH
1 8 1
675 550 6 6
6 9 6 6
FDNS
BASE ANCHOR
3/8THH
6
CB4G AB4
GA65GD
3
5/8TBE&J
ANCHORS &
GROUNDING
INCLUDED
AGK1GGX BGK2GGX
3 1 3
TBSAFETY
3
CPC1/1.25
3
GAC5655TOP
1/4EHS
475
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
65G 65TGH 6520G APL4HA
142261 142265 BG2147 BG2146
5/8TBE&J
7/16THH
1 1 8 1
725 1075 6 12
9 6 12
FDNS
BASE ANCHOR
CB4G AB4
GA65GD
3
1/2THH
ANCHORS &
GROUNDING
INCLUDED
AGK1GGX BGK2GGX
3 1 3
TBSAFETY
3
CPC1/1.25
3
GAC5655TOP
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
15/16x16PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
140
2011 ROHN PRODUCTS LLC
S TA NDA R D DE S I GN - 6 5 G
1 3 0 MP H R E V. G , 1 1 0 MP H R E V. F
P/N: 65G130R190
190 TOWER
180
27.0 22.1 OR
236
152
194
120
60 163
3/8EHS
(1,540#)
5/16EHS
(1,120#)
190 ROHN 65G
Al l par t s shown i n
t abl e are i ncl uded
when order i ng
Par t No: 65G130R190
9.0
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
65TGH 6520G APL4HA GA65GD
142261 142265 BG2147 BG2146 7/16THH
AGK1GGX BGK2GGX
1 9 1 3
750 1150 6 12 12
3 1 3
FDNS
BASE ANCHOR
1/2THH
6 9
5/8TBE&J
TBSAFETY
3
CPC1/1.25
3
CB4G AB4
GAC5655TOP 15/16x16PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
141
2011 ROHN PRODUCTS LLC
PA R T S & ACC E S S OR I E S
5 SHORT BASE
SB65GH
FOR EMBEDMENT IN CONCRETE.
SIDE ARM ASSEMBLY
SA253UA
MOUNTING TUBE PROVIDED IS 3 LONG,
2 1/4 O.D.
HOUSE BRACKET
KH1014
ADJUSTABLE TO POSITION 65G
18 - 30 FROM WALL.
FACE DISH MOUNT
DM654
4 1/2 O.D. X 5 LONG
DM654TB
4 1/2 O.D. X 5 LONG WITH TIE-BACK
ANGLE.
10 TAPERED BASE
65TGH*
FOR USE WITH 15/16X16PP,
ORDERED SEPARATELY.
CAP PLATE KIT
CP4A
(3) CAP PLATES WITH NUTS AND BOLTS.
LIGHTNING ROD
PLATE KIT
VW133
INCLUDES: LIGHTNING ROD PLATE,
(2) CAP PLATES, NUTS AND BOLTS.
PIER PIN
15/16X16PP
FOR USE WITH 65TGH
EMBEDDED IN CONCRETE.
PIER PIN MUST BE ORDERED
SEPARATELY, UNLESS BEING
PURCHASED AS PART OF
A COMPLETE TOWER KIT.
LEG MOUNTED
BEACON PLATE KIT
APL4HA
FOR MOUNTING BEACON OR
LIGHTNING ROD. BOLTS TO
TOP OF STANDARD SECTION.
INCLUDES BEACON PLATE,
(2) CAP PLATES, NUTS AND BOLTS.
LIGHTNING ROD
LRCL
5 COPPER CLAD
ORDERED SEPARATELY.
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
Adjustable
2.5 - 3.0
Tie-Back Angle
with 9/16 dia.
holes, included
with DM654TB.
6.2
DISH MOUNT
KY509 - 2 3/8 O.D. MAST
KY510 - 4 1/2 O.D. MAST
MOUNTING TUBE PROVIDED IS 5 LONG.
3 SIDE ARM
KH6100A
MOUNTING TUBE PROVIDED IS 7 LONG,
2 3/8 O.D.
6 SIDE ARM
KY1048A
MOUNTING TUBE PROVIDED IS 5 LONG,
2 3/8 O.D.
PA R T S & ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
142
2011 ROHN PRODUCTS LLC
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SYSTEM
ORDERING INFORMATION
TOWER
HEIGHT
50
100
150
200
250
300
350
400
450
500
PART
NUMBER
TT05065
TT10065
TT15065
TT20065
TT25065
TT30065
TT35065
TT40065
TT45065
TT50065
SAFETY CABLE
SLIDER WITH CARABINEER
TT-WG-500-W/SMC
GUY BRACKET ASSEMBLY
GA65GD
KIT INCLUDES (3) BRACKETS WITH
U-BOLTS.
WORK PLATFORM
WPCC65
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
ANTI-CLIMB PANELS
VW915A
THREE ANTI-CLIMB PANELS BOLT
TO STANDARD TOWER SECTION.
SAFETY CABLE SLIDER AND
CLIMBING HARNESS MUST BE
ORDERED SEPARATELY.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
143
2011 ROHN PRODUCTS LLC
REV G
ANCHOR GROUNDING
AGK1GGX
REV G
BASE GROUNDING
BGK2GGX
A NC HOR I NF OR MAT I ON
3/8
2
12
3/4 P/N STAMPED HERE
GAC3455TOP
1/2
2 1/2
12
120
1 1/4 P/N STAMPED HERE
GAC5655TOP
81
3/4
3
12
168
1 7/16 P/N STAMPED HERE
GAC5755TOP
11/16
13/16
15/16
4 x 4 x 3/8 angle
5 x 5 x 3/8 angle
C
L
of hole to edge
of plate = 1 1/4
C
L
of hole to edge
of plate = 1
C
L
of hole to edge
of plate = 1 1/4
5 x 5 x 3/8 angle
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp
6 Min.
Attach to leg with
supplied leg clamp
Ground Wire
6 Min.
Ground Rod Clamp
Ground Rod,
3 provided (to be installed
at 120 separation at 20 spacing.
o
G
GUY E D T OWE R S - 6 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
144
2011 ROHN PRODUCTS LLC
All around stirrups
equally spaced 12
O.C. anchored with 90
hooks around a
horizontal bar
Top and bottom
horizontal bars
equally spaced
C
B
A
Ground Line
D
Anchor rod
o
Additional bar at
center-line each
side, when required
S TA NDA R D A NC HOR B L OC K S
Block
AB2
AB3
AB4
AB5
AB6
A
4 - 0
6 - 0
6 - 0
8 - 0
8 - 0
Concrete Vol.
(Cu. Yds.)
1.33 Per Block
4.0 Total for 3
1.0 Per Block
3.0 Total for 3
2.0 Per Block
6.0 Total for 3
2.22 Per Block
6.7 Total for 3
2.96 Per Block
8.9 Total for 3
B
1 - 6
1 - 6
1 - 6
2 - 0
2 - 0
C
4 - 0
3 - 0
4 - 0
3 - 0
4 - 0
Horizontal Bars
(Qty. & Size)
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer
(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer
(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer
(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
D
6 - 0
6 - 0
9 - 0
10 - 0
10 - 0
Anchor Dimensions (in.)
Stirrup Size
& Spacing
#3 @ 12 O.C.
#3 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
#4 @ 12 O.C.
Refer to page 145 for anchor rod installation angles.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 6 5 G
145
2011 ROHN PRODUCTS LLC
A NC HOR R OD I NS TA L L AT I ON A NGL E S
120
o
Ground Line
Rod Angle
(in degrees)
Tower
Height
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
360
380
400
420
440
460
480
500
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Inner
Rod
Angle
44
44
44
44
42
42
42
41
41
41
41
40
39
39
38
38
38
43
43
43
40
40
40
40
40
39
65G | 90MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
43
43
43
44
43
43
42
42
42
Tower
Height
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
Inner Rod
Number
GAC3455TOP
GAC3455TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5755TOP
GAC5655TOP
Inner
Rod
Angle
44
43
42
42
41
41
41
40
40
40
39
39
38
38
37
37
37
43
65G | 110MPH
Outer Rod
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GAC5755TOP
Outer
Rod
Angle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
42
Tower
Height
100
110
120
130
140
150
160
170
180
190
Rod
Number
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
GAC5655TOP
Rod
Angle
42
42
41
41
40
40
40
39
38
38
65G | 130MPH
Tower Plan Anchor Rod Angle
G
GUY E D T OWE R S - 6 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
146
2011 ROHN PRODUCTS LLC
S TA NDA R D B A S E P I E R S
Base
CB2G
CB3G
CB4G
CB5G
CB6G
CB7G
A
3 - 0
3 - 6
4 - 0
2 - 0
2 - 0
2 - 0
Vertical Bars
(No. & Size)
(10) #7
(12) #7
(12) #8
(8) #6
(8) #6
(8) #6
Concrete Vol.
(Cu. Yds.)
Round Pier
1.2
1.6
2.1
1.1
1.3
1.6
B
3 - 0
3 - 6
4 - 0
4 - 0
4 - 6
5 - 0
C
N/A
N/A
N/A
1 - 0
1 - 3
1 - 6
Horiz. Bars
in Pad
(No. & Size)
NONE
NONE
NONE
(5) #5
(Total of 10)
(6) #5
(Total of 12)
(6) #5
(Total of 12)
D
4 - 0
4 - 0
4 - 0
4 - 0
4 - 0
4 - 6
E
N/A
N/A
N/A
3 - 3
3 - 3
3 - 9
F
N/A
N/A
N/A
1 - 3
1 - 3
1 - 3
Alternate
Square
Pier
PLAN VIEW
A
B
No. 4 Circular ties, 3 O.C.
with 24 laps
Vertical bars equally spaced
(2) No. 4 Circular ties, 2-1/2 O.C.
with 2 cover with 24 laps
4 Projection
6
No. 4 Circular ties, 3 Max. O.C.
with 24 laps
Vertical re-bars equally spaced
with 90 hooks at bottom (for CB5G - CB7G)
Roughen construction joint to
a full amplitude of 1/4
Foundation Pad
Horizontal reinforcing
steel bars equally spaced
each way
C
E
D
F
ELEVATION VIEW
B
Pier Pin
Grade
A C
L
C
L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S
147
2011 ROHN PRODUCTS LLC
GE NE R A L NOT E S F OR G- S E R I E S T OWE R S
1. Standard foundation designs (unless otherwise noted) are in accordance with ANSI/TIA-222-G, Structural Standards
for Steel Antenna Towers and Antenna Supporting Structures, Section 9 and Annex F for the following presumptive
clay soil parameters:
2. The purchaser must verify that actual site soil parameters meet or exceed the assumed soil conditions and that the
depth of standard foundations are adequate based on the frost penetration and/or zone of seasonal moisture variation
at the site. Foundation design modifications may be required in the event the assumed soil parameters are not
applicable for the actual subsurface conditions encountered.
N
(blows/ft)
O
(deg)
Y
(lb/ft )
3
c
(psf)
Ultimate Bearing
(psf)
Shallow
Fdns.
Deep
Fdns.
Ultimate Skin
Friction
(psf)
k
(pci)
50
8 0 110 1000 5000 9000 500 150 0.01
1. The suitability of a ROHN standard design and standard foundation for a specific application must be verified by the
purchaser based on site-specific data in accordance with ANSI/TIA-222-G.
2. The effective projected area and lines to be installed must not exceed the design values for the structure.
3. Structures supported on buildings or other strucutres require special consideration. Designs assume structures are
installed on level grade.
4. Designs assume maintenance and inspection will be performed over the life of the structure in accordance with
ANSI/TIA-222-G. All towers should be thoroughly inspected by qualified personnel and re-marked as required with
appropriate danger and anti-climb labels at least twice a year to ensure safety and proper performance.
5. Standard Designs are intended to be climbed by skilled and competent climbers only. A safety climb system is required
for all structures.
6. Installation and dismantling must be performed by qualified and experienced personnel and be in conformance
with ANSI/TIA-222-G.
7. Standard guyed masts and bracketed towers are not stable without guys or brackets attached and will not support
personnel in this condition. Temporary steel guys supplied by a qualified contractor may be required to maintain
stability during installation or dismantling.
8. Do not install or dismantle structures within falling distance of electrical and/or telephone lines without taking
special precautions in accordance with the appropriate utility.
9. All field connections are bolted.
10. The tolerance on installed height is equal to plus 1% and minus 1/2%.
11. Installation must be grounded in accordance with local and national codes. ANSI/TIA-222-G requires that the
resistance to ground must not exceed 10 ohms. Additional grounding may be required in addition to the ROHN
standard grounding kit provided with the tower.
12. Additional anchor rod corrosion protection may be required based on site-specific conditions.
13. Installation must be in conformance with local, state and federal requirements for obstruction marking and lighting.
14. Warning plate P/N: AWCS provided with the structure must be installed in a highly visible location.
G- S E R I E S F OUNDAT I ON GE NE R A L NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GUY E D T OWE R S
2011 ROHN PRODUCTS LLC
G
148
G- S E R I E S F OUNDAT I ON GE NE R A L NOT E S
3. Foundation designs assume field inspections will be performed by the purchasers representative to verify that construction
materials, installation methods and assumed design parameters are acceptable based on the conditions existing at the site.
4. Work shall be in accordance with local codes, safety regulations and unless otherwise noted, the latest revision of ACI 318,
Building Code Requirements for Reinforced Concrete. Procedures for the protection of excavations, existing construction
and utilities shall be established prior to foundation installations.
5. Concrete materials shall conform to the appropriate state requirements for exposed structural concrete.
6. Proportions of concrete materials shall be suitable for the installation method utilized and shall result in durable concrete
for resistance to local anticipated aggressive actions. The durability requirement of ACI 318 Chapter 4 shall be satisfied based
on the conditions expected at the site. As a minimum, concrete shall develop a minimum compressive strength of 4000 psi
in 28 days.
7. Maximum size of aggregate shall not exceed the size suitable for the installation method utilized or 1/3 the clear distance
behind or between reinforcing. Maximum size may be increased to 2/3 the clear distance provided workability and methods
of consolidation such as vibrating will prevent honeycombs or voids.
8. Reinforcement shall be deformed and conform to the requirements of ASTM A615 Grade 60 unless otherwise noted.
Splices in reinforcement shall not be allowed unless otherwise indicated.
9. Reinforcing cages shall be braced to retain proper dimensions during handling and throughout placement of concrete.
10. Welding is prohibited on reinforcing steel and embedments.
11. Minimum concrete cover for reinforcement shall be 3 inches unless otherwise noted. Appropriate spacers shall be used
to insure a 3 inch minimum cover on reinforcement.
12. Concrete cover from top of foundations to ends of vertical reinforcement shall not exceed 3 inches nor be less than
2 inches.
13. Spacers shall be attached intermittently throughout the entire length of vertical reinforcing cages to insure concentric
placement.
14. Foundation designs assume structural backfill to be compacted in 8 inch maximum layers to 95% of maximum dry
density at optimum moisture content in accordance with ASTM D698. Additionally, structural backfill must have a minimum
compacted until weight of 100 pounds per cubic foot.
15. Foundation designs assume level grade at the site.
16. Foundation installations shall be supervised by personnel knowledgeable and experienced with the proposed foundation
type. Construction shall be in accordance with generally accepted installation practices.
17. Loose material shall be removed from bottom of excavations prior to concrete placement. Sides of excavations shall be
rough and free of loose cuttings.
18. Concrete shall be placed in a manner that will prevent segregation of concrete materials and other occurrences which
may decrease strength or durability.
19. Free fall concrete may be used provided fall is vertical down without hitting sides of excavation, form work, reinforcing
bars, form ties, cage bracing or other obstructions. Under no circumstances shall concrete fall through water.
20. Concrete shall be placed against undisturbed soil except for piers in pier and pad foundations. Forms for piers shall be
removed prior to placing structural backfill.
21. Construction joints, if required in piers must be at least 12 inches below bottom of embedments and must be intentionally
roughened to a full amplitude of 1/4 inch. Foundation designs assume no other construction joints.
22. Tops of foundations shall be sloped to drain with a floated finished.
23. Exposed edges of concrete shall be chamfered 3/4 x 3/4.
24. Additional corrosion protection may be required for steel guy anchors in direct contact with soil. Design assumes
periodic inspections will be performed over the life of the structure to determine if additional anchor corrosion protection
measures must be implemented based on observed site-specific conditions.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S
149
2011 ROHN PRODUCTS LLC
F OUNDAT I ON T OL E R A NC E S
1. Concrete dimensions - plus 2 or minus 0.
2. Depth of foundation - plus 3 or minus 0.
3. Drilled foundations out-of-plumb - 1.0 degree.
4. Reinforcing steel placement - per A.C.I. 301.
5. Projection of embedments - plus or minus 1/8.
6. Vertical embedments out of plumb - 0.5 degree.
1. Guy radius - plus or minus 5% of distance specified.
2. Anchor elevation - plus or minus 5% of guy radius.
3. Anchor alignment (perpendicular to guy radius) - 1.0 degree.
4. Anchor rod slope - plus or minus 1.0 degree.
5. Anchor rod alignment with guy radius - plus or minus 1.0 degree.
6. Anchor head out of plumb - 1.0 degree.
7. Guy initial tension - plus or minus 10% of tension specified.
Note: Tolerances in notes 1 & 2 cannot occur simultaneously.
GUY A NC HOR S
GE NE R A L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GUY E D T OWE R S
2011 ROHN PRODUCTS LLC
G
150
GUY A R R A NGE ME NT DE TA I L S
1 Guy Attachment 2 Guy Attachment 3 Guy Attachment
4 Guy Attachment 5 Guy Attachment
Turnbuckle (TYP)
Anchor Rod (TYP)
Wire Size Anchor Rod Thimble Turnbuckle
3/16 EHS
1/4EHS
5/16EHS
3/8EHS
GAC3455TOP
GAC5655TOP
GAC3455TOP
GAC5655TOP
GAC5755TOP
GAC3455TOP
GAC5655TOP
GAC5755TOP
GAC3455TOP
GAC5655TOP
GAC5755TOP
1/2TBE&J
5/8TBE&J
1/2TBE&J
5/8TBE&J
3/4TBE&J
5/8TBE&J
5/8TBE&J
3/4TBE&J
5/8TBE&J
5/8TBE&J
3/4TBE&J
5/16THH
5/16THH
3/8THH
3/8THH
3/8THH
7/16THH
7/16THH
7/16THH
1/2THH
1/2THH
1/2THH
Big Grip w/ End Sleeve
BG2142
BG2144
BG2146
BG2174
GUY A NC HOR CONNE C T I ON DE TA I L S
End Sleeve
Turnbuckle (TYP)
Equalizer Plate
Anchor Rod
Thimble (TYP)
Big Grip Preform (TYP)
Cable Clamps
Turnbuckle Safety Cables
1/4 EHS Wire (up to 1 turnbuckles)
5/16 EHS Wire (1 1/4 turnbuckles & larger)
Anchor Connection
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S
151
2011 ROHN PRODUCTS LLC
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GUY E D T OWE R S
2011 ROHN PRODUCTS LLC
G
152
GUY MA S T CONNE C T I ON DE TA I L S
Tower Brace (REF)
Tower Leg (REF)
Guy bracket must rest on
horizontal tower brace and
lugs when provided
for larger guys. Big Grip Preform
Thimble
Guy Link
Guy Bracket Connection
25G, 45G, 45GSR, 55G
Guy Lug Connection
45GSR
Tower Brace (REF)
Tower Leg (REF)
Guy Lug
Shackle
Thimble
Big Grip Preform
Guy Tension Bar
Bolt-On Guy Bracket Connection
65G
Tower Brace (REF)
Tower Leg (REF)
Big Grip Preform
Thimble
Bolt-On
Guy Bracket
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S
153
2011 ROHN PRODUCTS LLC
PA L NUT I NS TA L L AT I ON
When pal nuts are provided, they are to be installed after nuts are tight and with edge lip out as shown. Pal nuts are not
required when self-locking nuts or lock washers are provided.
Flange Plates
Pal Nut
Bolt
Nut
Tower Leg
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 8 0
2011 ROHN PRODUCTS LLC
S TA NDA R D 8 0 S E R I E S GUY E D T OWE R
154
GENERAL USE
The ROHN Model 80 Guyed Tower is designed
with variable sized legs and braces to allow
construction to heights of 1000. This tower uses
solid or tubular legs with angle or tubular braces
to support microwave, cellular, PCS, AM/FM or
TV applications. The tower is designed on an
equilateral triangle of 41 center-to-center of
each leg. The variable leg and brace sizes allow
fexibility in design so a tower can be created
specifcally for your unique requirements.
FEATURES
Solid or Tubular Legs
Angle or Tubular Braces
Completely hot-dip galvanized after fabrication
Easily reinforced for additional loading capability
Multiple section lengths available
Guy lug and torque arm sections available
80
SERIES
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
S TA NDA R D 8 0 GUY E D T OWE R
S E C T I ONS
Tower Axis
PLAN VIEW
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GUY E D T OWE R S - 8 0
2011 ROHN PRODUCTS LLC
G
155
SINGLE BRACED DOUBLE BRACED
35 1/2
23 11/16
41
Tubular or Solid
Round Legs
Tubular or Angle
Bracing
20 STANDARD SECTION
80 Sections have several custom designs
available depending on your particular
specifications. Sections are available with
a variety of different wall thicknesses,
bracing patterns and lengths.
Tubular or
Solid Round
Leg
Angle Braces
5 TAPERED BASE
Pier Pin
Bearing Plate
S TA NDA R D 9 0 S E R I E S GUY E D T OWE R
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
G
GUY E D T OWE R S - 9 0
156
2011 ROHN PRODUCTS LLC
GENERAL USE
The ROHN Model 90 Guyed tower is designed
specifcally for microwave installations, cellular,
PCS, other heavy duty communication, TV and
FM broadcast and meteorological equipment
installations. This series has a rating for installations
up to 1500, using variable size and weight of
tubular or solid steel components. The tower is
designed on an equilateral triangle of 60 1/2
center-to-center of each leg. The X brace
design of the 90 series maximizes strength in
critical areas as well as allows for future upgrading
of the tower for additional loads.
FEATURES
Solid or Tubular Legs
Angle Braces
Completely hot-dip galvanized after fabrication
Easily reinforced for additional loading capability
Multiple section lengths available
Guy lug and torque arm sections available
90
SERIES
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
ELEVATION
20 STANDARD SECTION
S TA NDA R D 9 0 GUY E D T OWE R
S E C T I ONS
60 1/2
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GUY E D T OWE R S - 9 0
2011 ROHN PRODUCTS LLC
G
157
TAPERED BASE
STANDARD - 10
Also available in 8
90 Sections have several custom designs available
depending on your particular specifications. Sections
are available with a variety of different wall thicknesses,
bracing patterns and lengths.
Pier Pin
Bearing Plate
52 3/8
34 15/16
Angle Bracing
Tubular or Solid
Round Legs
Custom designs with larger face widths are
available for broadcast and other applications.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
NOT E S
158
B
B R AC K E T E D T OWE R S
S TA NDA R D G- S E R I E S B R AC K E T E D
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
160
UNIVERSAL HOUSE BRACKET
HBUTVRO
Adjustable to position tower 18 - 36 from wall.
OP T I ON A L A C C E S S OR Y
Typical installation on short base with (2)
HBUTVRO brackets.
(Refer to G-Series accessories for short base)
* Per Rev. G requriements, any structure greater than
10 requires a climber safety device. Please see page
209 for ordering information.
GENERAL USE
ROHN G-Series Bracketed towers can be installed
adjacent to buildings using brackets to secure
the tower along the height of the structure.
FEATURES
Completely hot-dip galvanized after fabrication
Cross bracing is formed by a continuous solid
rod bracing fashioned into a Zig-Zag pattern
for strength
Pre-engineered loading charts to meet varying
individual specs and site conditions
Typical uses include: small dishes, broadband,
security and two-way communication.
G-SERIES
(BRACKETED)
2 5 G B R AC K E T E D
A L L OWA B L E A N T E N N A A R E A S
B R AC K E T E D T OWE R S - 2 5 G
B
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
161
Tower Height
(FT.)
40
50
60
70
80
90
100
Upper (FT.)
30.0
36.0
46.0
56.0
66.0
66.0
66.0
Lower (FT.)
15.0
18.0
23.0
28.0
33.0
33.0
33.0
Bracket Elevations Allowable Antenna Areas (SQ. FT.)
70 [85] MPH
15.3
14.6
14.0
13.5
13.1
6.8
1.7
80 [95] MPH
11.3
10.0
8.9
8.3
7.7
4.9
-
90 [105] MPH
7.7
6.8
5.9
5.5
5.0
-
-
1. Tower designs are in accordance with ANSI/EIA-222-F. Wind speeds indicated as fastest mile [3-second gust].
2. All towers must have fixed baseswith both bracket elevations. Pinned bases must not be used.
3. Designs assume one 5/8transmission line on each face (total=3), symmetrically placed.
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. All brackets are to be ROHN (P/N HBUTVRO).
8. The interface of tower brackets to supporting structure is to be designed by others and must support a minimum horizontal force of 815 lbs.
9. Foundation designs are in accordance with ANSI/TIA/EIA-222-F, Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures, Section 7, for Normalsoil conditions. Normalsoil is defined as dry, cohesive soil with an allowable net vertical bearing
capacity of 4000 PSF and an allowable net horizontal pressure of 400 PSF per linear foot of depth to a maximum of 4000 PSF.
Refer to pages 147-153 for General Installation and Foundation Notes.
F OU N D AT I ON I N F OR MAT I ON
SB25G5 Base Section
or Tower Base Section
6 Projection
6
2 Min.
Compacted Sand &
Gravel Drainage Bed
2 - 6 Round
or Square
Tower Axis and
Center of Pier
VOLUME OF CONCRETE
Square Pier 1.0 cu. yds.
Round Pier 0.8 cu. yds.
=
=
4 - 0
#3 Circular Ties
at 3 Max O.C.
W/ 18 Laps
(8) #7 Vertical
Bars Equally
Spaced
25G
Grade
6 Min.
4 5 G B R AC K E T E D
A L L OWA B L E A N T E N N A A R E A S
Tower Height
(FT.)
40
50
60
70
80
90
100
Upper (FT.)
30.0
36.0
46.0
56.0
66.0
66.0
66.0
Lower (FT.)
15.0
18.0
23.0
28.0
33.0
33.0
33.0
Bracket Elevations Allowable Antenna Areas (SQ. FT.)
70 [85] MPH
36.7
34.8
33.3
32.0
31.0
13.8
5.5
80 [95] MPH
27.4
25.9
24.7
23.8
23.0
9.3
2.0
90 [105] MPH
21.0
20.0
19.0
17.0
12.0
5.3
-
B
B R AC K E T E D T OWE R S - 4 5 G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
162
45G
F OU N D AT I ON I N F OR MAT I ON
2 - 6 Round
or Square
Tower Axis and
Center of Pier
VOLUME OF CONCRETE
Square Pier 1.0 cu. yds.
Round Pier 0.8 cu. yds.
=
=
1. Tower designs are in accordance with ANSI/EIA-222-F. Wind speeds indicated as fastest mile [3-second gust].
2. All towers must have fixed baseswith both bracket elevations. Pinned bases must not be used.
3. Designs assume one 5/8transmission line on each face (total=3), symmetrically placed.
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. All brackets are to be ROHN (P/N HBUTVRO).
8. The interface of tower brackets to supporting structure is to be designed by others and must support a minimum horizontal force of 1810 lbs.
9. Foundation designs are in accordance with ANSI/TIA/EIA-222-F, Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures, Section 7, for Normalsoil conditions. Normalsoil is defined as dry, cohesive soil with an allowable net vertical bearing
capacity of 4000 PSF and an allowable net horizontal pressure of 400 PSF per linear foot of depth to a maximum of 4000 PSF.
Refer to pages 147-153 for General Installation and Foundation Notes.
SB45G5 Base Section
or Tower Base Section
6 Projection
6
2 Min.
Compacted Sand &
Gravel Drainage Bed
4 - 0
#3 Circular Ties
at 3 Max O.C.
W/ 18 Laps
(8) #7 Vertical
Bars Equally
Spaced
Grade
6 Min.
5 5 G B R AC K E T E D
A L L OWA B L E A N T E N N A A R E A S
B R AC K E T E D T OWE R S - 5 5 G
B
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
163
Tower Height
(FT.)
40
50
60
70
80
90
100
Upper (FT.)
30.0
36.0
46.0
56.0
66.0
66.0
66.0
Lower (FT.)
15.0
18.0
23.0
28.0
33.0
33.0
33.0
Bracket Elevations Allowable Antenna Areas (SQ. FT.)
70 [85] MPH
72.4
68.7
65.8
63.5
61.4
30.6
16.0
80 [95] MPH
54.5
51.7
49.5
47.5
46.0
22.0
10.5
90 [105] MPH
41.8
39.4
37.6
36.0
34.6
16.0
6.4
55G
F OU N D AT I ON I N F OR MAT I ON
SB55G Base Section
or Tower Base Section
6 Projection
6
2 Min.
Compacted Sand &
Gravel Drainage Bed
3 - 0 Round
or Square
Tower Axis and
Center of Pier
VOLUME OF CONCRETE
Square Pier 1.4 cu. yds.
Round Pier 1.1 cu. yds.
=
=
4 - 0
#3 Circular Ties
at 3 Max O.C.
W/ 18 Laps
(8) #7 Vertical
Bars Equally
Spaced
1. Tower designs are in accordance with ANSI/EIA-222-F. Wind speeds indicated as fastest mile [3-second gust].
2. All towers must have fixed baseswith both bracket elevations. Pinned bases must not be used.
3. Designs assume one 5/8transmission line on each face (total=3), symmetrically placed.
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying areas shown by 0.6.
7. All brackets are to be ROHN (P/N HBUTVRO).
8. The interface of tower brackets to supporting structure is to be designed by others and must support a minimum horizontal force of 3200 lbs.
9. Foundation designs are in accordance with ANSI/TIA/EIA-222-F, Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures, Section 7, for Normalsoil conditions. Normalsoil is defined as dry, cohesive soil with an allowable net vertical bearing
capacity of 4000 PSF and an allowable net horizontal pressure of 400 PSF per linear foot of depth to a maximum of 4000 PSF.
Refer to pages 147-153 for General Installation and Foundation Notes.
Grade
6 Min.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
164
NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S
166
2011 ROHN PRODUCTS LLC
S TA NDA R D G- S E R I E S S E L F - S UP P OR T I NG
Typical Self-Supporting
25G, 45G and 55G Tower
Typical Self-Supporting
45GSR and 65G Tower
REV. G
includes
REV. F&
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 209 for ordering information.
GENERAL USE
The self-supporting G-Series towers ofer an easy,
low-cost solution to get light weight antennas in
the air quickly. By using the G-Series tower as a
self-supporting structure, you minimize land
area usage. They are functional in a wide variety
of wind speeds. See ROHNs standard designs
to help identify the right structure for your project.
These are the same sturdy, robust tower sections
that ROHN has fabricated for years. Each larger
model allows for more loading capacity.
FEATURES
Completely hot-dip galvanized after fabrication
Cross bracing is formed by a continuous solid
rod bracing fashioned into a zig-zag pattern
for strength
Pre-engineered loading charts meet varying
individual specs and site conditions
Typical uses include: small dishes, broadband,
security and two-way communication
All towers have fxed bases
KITS
The kit part numbers for ROHN Self-Supporting
G-Series towers include:
Short base for embedment in concrete
Rev F ground kit
All tower sections and connection hardware
Tapered top (25G and 45G towers)
Top plate (55G towers)
Cap plate kit (65G towers)
G-SERIES
SELF-SUPPORTING
Note: Antenna areas, ft. , assume all round antenna members.
2
167
Exp.B
82
74
66
59
46
35
27
20
13
Part No.
45SR010
45SR020
45SR030
45SR035
45SR040
45SR045
45SR050
45SR055
45SR060
45GSR
Exp.C
66
55
43
38
30
22
15
9
4
Exp.B
95
95
87
76
60
48
38
29
22
Part No.
45SR010
45SR020
45SR030
45SR035
45SR040
45SR045
45SR050
45SR055
45SR060
EPA
Exp.C
84
71
58
52
40
31
23
16
11
Height
10
20
30
35
40
45
50
55
60
Exp.B
16.5
10.6
3.1
110 MPH 3-Second Gust Wind Speed
Part No.
25SS010
25SS020
25SS030
25G
Exp.C
12.7
7.2
0.4
Exp.B
39.4
18.3
6.5
1.7
Part No.
45SS010
45SS020
45SS030
45SS035
45G
Exp.C
31.9
12.3
1.9
-
Exp.B
63
34
17
11
5
Part No.
55SS010
55SS020
55SS030
55SS035
55SS040
55G
Exp.C
51
25
9
4
-
Exp.B
95
95
65
48
35
25
17
10
4
Part No.
65SS010
65SS020
65SS030
65SS035
65SS040
65SS045
65SS050
65SS055
65SS060
65G
Exp.C
95
81
43
30
21
13
7
-
-
Height
10
20
30
35
40
45
50
55
60
Exp.B
20.7
14.0
5.3
2.1
100 MPH 3-Second Gust Wind Speed
Part No.
25SS010
25SS020
25SS030
25SS035
25G
Exp.C
16.4
9.9
2.2
-
Exp.B
47.4
23.2
9.7
5.1
1.2
Part No.
45SS010
45SS020
45SS030
45SS035
45SS040
45G
Exp.C
39.5
16.9
4.8
0.7
-
Part No.
55SS010
55SS020
55SS030
55SS035
55SS040
55SS045
55G
Exp.C
63
32
14
8
3
-
Exp.B
95
95
81
61
47
35
26
17
11
Part No.
65SS010
65SS020
65SS030
65SS035
65SS040
65SS045
65SS050
65SS055
65SS060
65G
Exp.C
95
95
55
40
29
20
13
6
1
G S E R I E S
R E V. G E F F E C T I V E P R OJ E C T E D A R E A ( S Q. F T. )
N
O

I
C
E
9
0

M
P
H
1
0
0

M
P
H
1
1
0

M
P
H
Height
10
20
30
35
40
45
50
55
60
Exp.B
26.8
18.5
7.9
4.4
1.3
90 MPH 3-Second Gust Wind Speed
Part No.
25SS010
25SS020
25SS030
25SS035
25SS040
EPA
Exp.C
21.3
13.4
4.1
1.2
-
Exp.B
60.0
31.3
16.1
9.8
4.9
0.7
Part No.
45SS010
45SS020
45SS030
45SS035
45SS040
45SS045
EPA
Exp.C
47.5
22.7
8.4
3.8
-
-
Part No.
55SS010
55SS020
55SS030
55SS035
55SS040
55SS045
55SS050
EPA
Exp.C
79
42
21
14
8
3
-
Exp.B
95
95
95
80
62
48
37
28
20
Part No.
65SS010
65SS020
65SS030
65SS035
65SS040
65SS045
65SS050
65SS055
65SS060
EPA
Exp.C
95
95
71
54
41
30
21
14
7
3
-
S
e
c
o
n
d

G
u
s
t
3
-
S
e
c
o
n
d

G
u
s
t
3
-
S
e
c
o
n
d

G
u
s
t
Exp.B
67
59
51
45
35
26
19
13
7
Part No.
45SR010
45SR020
45SR030
45SR035
45SR040
45SR045
45SR050
45SR055
45SR060
45GSR
Exp.C
53
43
32
27
22
15
9
4
-
Exp.B
78
43
24
17
10
5
Exp.B
80
56
34
25
17
11
5
45GSR 25G 45G 55G 65G
EPA EPA EPA EPA EPA
EPA EPA EPA EPA EPA
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S
168
2011 ROHN PRODUCTS LLC
Note: Antenna areas, ft. , assume all round antenna members.
2
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
169
SS
W
(Square)
Tower Axis &
Center of Pad
C
L
C
L
PLAN VIEW
Tower Section or
Short Base Section
#7 Bars 12
on Center
Each Way
6
6
4
2 min. projection required
for proper drainage
Compacted Sand & Gravel
Drainage Bed - not required
for 45GSR
Grade
25G
45G
55G
45GSR
65G
4 - 0
5 - 3
6 - 0
7 - 9
2.4
4.1
5.3
8.9
Tower
Mat
Width
(W)
Concrete
Volume
(Cu. Yds.)
CONCRETE BASE PLATE
WITH ANCHORS
25GSSB
FOR USE WITH SELF-SUPPORTING
25G TOWERS.
ALTERNATIVE TO USING SHORT BASE.
BASE BOLTS & TEMPLATE MUST
BE ORDERED SEPARATELY.
S E L F - S UP P OR T I NG G- S E R I E S F OUNDAT I ONS
Grade 6
4
Grade 6
#7 Bars 12
on Center
Each Way,
Top & Bottom
ELEVATION VIEW
25G (shown), 45G & 55G
SELF-SUPPORTING TOWER FOUNDATION
ELEVATION VIEW
45GSR
SELF-SUPPORTING TOWER FOUNDATION
ELEVATION VIEW
65G
SELF-SUPPORTING TOWER FOUNDATION
BASE BOLTS & TEMPLATE
KH8175A
FOR USE WITH 25GSSB
IN SELF-SUPPORTING 25G TOWER
APPLICATIONS. KIT INCLUDES (1)
TEMPLATE & (4) BASE BOLTS.
2 min. projection
above the fnished
concrete
6 min. projection
above the fnished
concrete
4
0 to 3
2 Min.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S
170
2011 ROHN PRODUCTS LLC
SELF-SUPPORTING G-SERIES DESIGN NOTES
1. Tower designs are in accordance with approved national standard ANSI/EIA-222-F and ANSI/TIA-222G,
Structure Class I, Exposures B and C, Topographic Category I.
2. All towers must have fixed bases. Pinned bases may not be used.
3. Designs assume transmission lines symmetrically placed as follows:
25G Tower - One 5/8 Line on each face (Total =3)
45G Tower - One 7/8 Line and one 1/2 line on each face (Total = 3 @ 7/8 & 3 @ 1/2)
55G & 65G Towers - Two 7/8 Lines on each face (Total =6)
4. Antennas and mounts assumed symmetrically placed at tower apex.
5. Rev F tabulated allowable antenna areas assume all round antenna members.
6. Allowable flat-plate antenna areas, based on EIA RS-222-C, may be obtained by multiplying Rev. F Antenna areas
shown by 0.6.
7. Standard foundation designs are based on Rev. F normal soil and Rev. G presumptive clay soil parameters.
Refer to pages 147-153 for General Installation and Foundation Notes.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
171
2011 ROHN PRODUCTS LLC
NOT E S
1 1 0 MP H 3 - S E C G U S T WI N D S P E E D ( N O I C E ) ,
4 0 MP H 3 - S E C G U S T WI N D S P E E D ( 3 / 4 I C E ) ,
C L A S S I I , E X P OS U R E C , T OP O C AT E G OR Y 1
S E I S MI C C OE F F I C I E N T S 1 . 0
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S
172
2011 ROHN PRODUCTS LLC
STANDARD 65G SELF-SUPPORTING CAMERA TOWERS (all-welded)
5-0
Square
3.7 cu. yds. concrete
6-0
Square
5.3 cu. yds. concrete
7-3
Square
7.8 cu. yds. concrete
8-0
Square
9.5 cu. yds. concrete
10
20
30
40
50
65SS010CT
328 lbs.*
65SS020CT
502 lbs.*
65SS030CT
695 lbs.*
65SS040CT
868 lbs.*
65SS050CT
1061 lbs.*
Tower
Height
10
20
30
40
50
Max. Tip Deflection
at 60 MPH
0.10
0.10
0.40
1.00
1.80
Maximum Load at Top

EPA
No Ice
14.5 ft.
7.0 ft.
EPA
With Ice
29.0 ft.
14.0 ft.
2
4-9
Square
3.3 cu. yds. concrete
Includes short base section, tower sections, Rev G grounding material and 3/16 top mounting plate with attachment hardware.
Tower Heights
10 - 40
50
24 1/4 Face Width (TYP)
R E V. G:

2
2
2
A
L
L

W
E
L
D
E
D
S
<
_
Per Rev. G requirements, any structure greater than 10 requires a climber safety device.
Please see page 173 for ordering information.
Standard 65G
Section (TYP)
* Tower Weight
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
173
SS
6 5 G C A ME R A T OWE R S
S TA N D A R D F OU N D AT I ON D E TA I L S
1. Tower designs are in accordance with ANSI/TIA/222-G.
2. Camera and mount assumed symmetrically placed at tower top.
3. Tower design assumes one 7/8 line on each tower face.
4. Assembly drawings and standard foundation details are provided with the tower.
5. Standard foundation illustrated is for general information only and is based on Rev G presumptive clay soil parameters.
Tower Axis
1 - 2
1 - 9
C
L
C
L
2-1/4
W
Square
W/2
W/2
6 of Compacted Sand
& Gravel for Drainage
3 - 6
2 Min.
#7 Horizontal Bars
12 O.C. Each Way
(Top & Bottom)
6
G E N E R A L N OT E S
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE
SLIDER WITH CARABINEER
TT-WG-500-W/SMC
ANTI-CLIMB PANELS
VW915A
ORDERED SEPARATELY
A C C E S S OR I E S
Grade
See tower elevation page for W dimension.
SAFETY CABLE SYSTEM
TT05065
FITS ALL TOWER HEIGHTS
2 Min.
R E V. G:

S
<
_
1 1 0 MP H 3 - S E C G U S T WI N D S P E E D ( N O I C E ) ,
4 0 MP H 3 - S E C G U S T WI N D S P E E D ( 3 / 4 I C E ) ,
C L A S S I I , E X P OS U R E C , T OP O C AT E G OR Y 1
S E I S MI C C OE F F I C I E N T S 1 . 0
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S
174
2011 ROHN PRODUCTS LLC
STANDARD VG SELF-SUPPORTING CAMERA TOWERS (field bolted)
5-6
Square
4.5 cu. yds. concrete
6-0
Square
5.3 cu. yds. concrete
7-3
Square
7.8 cu. yds. concrete
8-0
Square
9.5 cu. yds. concrete
10
20
30
40
50
VG010CT
500 lbs.*
VG020CT
735 lbs.*
VG030CT
1016 lbs.*
VG040CT
1251 lbs.*
VG050CT
1531 lbs.*
Tower
Height
10
20
30
40
50
Max. Tip Deflection
at 60 MPH
0.10
0.10
0.20
0.70
1.30
Maximum Load at Top


EPA
No Ice
14.5 ft.
7.0 ft.
EPA
With Ice
29.0 ft.
14.0 ft.
2
5-0
Square
3.7 cu. yds. concrete
Includes anchor bolts, templates, tower sections, Rev G grounding material, 1/2top mounting plate with attachment hardware and step bolts.
Tower Heights
10 - 40
50
30 Face Width (TYP)
2
2
2
K
N
O
C
K
E
D

D
O
W
N
Per Rev. G requriements, any structure greater than 10 requires a climber safety device.
See page 175 for ordering information.
2 3/8 O.D.
Tubular Legs
(TYP)
1 1/2 x 1/8
Angle Bracing
(TYP)
* Tower Weight
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
175
SS
VG C A ME R A T OWE R S
S TA N D A R D F OU N D AT I ON D E TA I L S
1. Tower designs are in accordance with ANSI/TIA/222-G.
2. Camera and mount assumed symmetrically placed at tower top.
3. Tower design assumes one 7/8 line on each tower face.
4. Assembly drawings and standard foundation details are provided with the tower.
5. Standard foundation illustrated is for general information only and is based on Rev G presumptive clay soil parameters.
Refer to pages 147-153 for Foundation General Notes.
Tower Axis
C
L
C
L
2- 6
W
Square
W/2
W/2
3 - 6
#7 Horizontal Bars
12 O.C. Each Way
(Top & Bottom)
6
G E N E R A L N OT E S
A C C E S S OR I E S
Anchor Bolts
See Anchor Bolt layout provided with
tower prior to placing concrete.
Grade
See tower elevation page for W dimensions.
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE
SLIDER WITH CARABINEER
TT-WG-500-W/SMC
ANTI-CLIMB PANELS
VW917A
ORDERED SEPARATELY
14
21
SAFETY CABLE SYSTEM
TT050SSL
FITS ALL TOWER HEIGHTS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S - R S L
176
2011 ROHN PRODUCTS LLC
18
21
25
28
32
35
38
42
45
49
52
Top Mount
GENERAL USE
The ROHN RSL is a light weight self-supporting
tower designed for use in broadband, public
safety and security applications. The RSL reaches
above line-of-site obstacles such as tree tops,
hilly terrain and buildings. If your site is remote
or rugged, the RSL is shipped knocked down to
reduce shipping cost and time.
RSL
FEATURES
Available in heights from 20 up to 100
High strength 60 formed angle legs
Aerodynamic tubular bracing
Easy to transport and assemble
Ships in 10 sections or knocked-down
Tower material is hot-dip galvanized
Assembly drawings provided with tower
Optional items are available and may be ordered
separately:
Step bolts
Safety climbing device
Top post
Anti-climb panels
Side arm mount
Dish mount
Grounding kit
Refer to page 185 for foundation details.
o
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please see page 184 for ordering information.
Nominal
face width
R1
10
R5
10
R6
10
R4
10
R7
10
R2
10
R8
10
R3
10
R9
10
R10
10
STANDARD RSL SELF-SUPPORTING TOWERS (field bolted)
S E L F - S UP P OR T I NG T OWE R S - R S L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
177
SS
18


28
R030L103
E.P.A. (ft. )
70
61
53
41
30
RSB03
RAL03
W
t
.

4
3
7

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
Face spread at
top of tower
Face spread at
base of tower
Tower weight
Wind speed and allowable EPA for each
The RSL short base or anchor bolt and
template base must be ordered separately
R 030 L 1 03
Tower
Model
Tower
Height
Load Scheme:
Light
Medium
Heavy
Tower top
section
Tower base
section
B UY E R S GUI DE
DESIGN NOTES:
1. Tower designs conform to ANSI/TIA/EIA-222-F for the basic wind speeds indicated without ice. Tower designs also conform to the
ANSI/TIA/EIA-222-F Standard for 1/2 inch radial ice load occuring simultaneously with 75% of the no ice design wind pressures.
2. Antennas and mounts are assumed to be symmetrically mounted at or below the top of the tower for determining overall reactions and
member forces. Design assumes the weight of antennas and mounts does not exceed 300 lbs.
3. Design assumes maximum top mast load is limited to 5 sq. ft. EPA and 100 lbs. vertical load. All other loading is assumed to be mounted
below the top mast.
4. Tower designs assume a 1/2 inch transmission line for each 10 square feet of EPA up to a maximum of three lines, one line per tower face.

5. Foundation designs are in accordance with ANSI/TIA/EIA-222-F, Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures, Section 7, for Normal soil conditions. Normal soil is defined as dry, cohesive soil with an allowable net vertical bearing
capacity of 4000 PSF and an allowable net horizontal pressure of 400 PSF per linear foot of depth to a maximum of 4000 PSF.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S - R S L
178
2011 ROHN PRODUCTS LLC
2
0


T
o
w
e
r
s
3
0


T
o
w
e
r
s
18
25
25

32
32

38
38

45
45

52
18


28
25


35
28


38
35


45
42


52
R020L102
E.P.A. (ft. )
70
61
53
42
33
RSB02
RAL02
W
t
.

2
9
0

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R020M304
E.P.A. (ft. )
80
74
65
48
35
RSB04
RAL04
W
t
.

2
9
5

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R020M506
E.P.A. (ft. )
80
80
68
50
36
RSB06
RAL06
W
t
.

3
0
2

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R020H708
E.P.A. (ft. )
80
80
80
80
65
RSB08
RAL08
W
t
.

3
9
9

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R020H910
E.P.A. (ft. )
80
80
80
80
68
RSB10
RAL10
W
t
.

4
7
7

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R030L103
E.P.A. (ft. )
70
61
53
41
30
RSB03
RAL03
W
t
.

4
3
7

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R030M305
E.P.A. (ft. )
80
74
65
45
29
RSB05
RAL05
W
t
.

4
4
5

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R030M406
E.P.A. (ft. )
80
78
64
43
28
RSB06
RAL06
W
t
.

4
5
0

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R030H608
E.P.A. (ft. )
80
80
73
55
42
RSB08
RAL08
W
t
.

5
5
1

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R030H810
E.P.A. (ft. )
80
80
80
80
60
RSB10
RAL10
W
t
.

6
8
7

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
S E L F - S UP P OR T I NG T OWE R S - R S L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
179
SS
4
0


T
o
w
e
r
s
18



32
21



35
28



42
35



49
38



52
18




35
21




38
25




42
32




49
35




52
5
0


T
o
w
e
r
s
R040L104
E.P.A. (ft. )
54
44
36
24
15
RSB04
RAL04
W
t
.

5
8
5

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R040M205
E.P.A. (ft. )
63
52
43
29
19
RSB05
RAL05
W
t
.

5
9
0

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R040M407
E.P.A. (ft. )
80
75
62
40
25
RSB07
RAL07
W
t
.

6
3
9

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R040H609
E.P.A. (ft. )
80
80
69
52
40
RSB09
RAL09
W
t
.

7
8
8

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R040H710
E.P.A. (ft. )
80
80
80
75
49
RSB10
RAL10
W
t
.

8
7
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R050L105
E.P.A. (ft. )
37
29
22
11
4
RSB05
RAL05
W
t
.

7
3
5

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R050M206
E.P.A. (ft. )
43
34
26
15
6
RSB06
RAL06
W
t
.

7
4
2

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R050M307
E.P.A. (ft. )
67
54
44
30
16
RSB07
RAL07
W
t
.

7
8
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R050H509
E.P.A. (ft. )
80
73
61
42
30
RSB09
RAL09
W
t
.

9
3
8

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R050H610
E.P.A. (ft. )
80
76
66
49
38
RSB10
RAL10
W
t
.

1
0
2
8

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S - R S L
180
2011 ROHN PRODUCTS LLC
6
0


T
o
w
e
r
s
18





38
21





42
25





45
28





49
32





52
R060L106
E.P.A. (ft. )
23
15
9
2
-
RSB06
RAL06
W
t
.

8
8
7

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R060M207
E.P.A. (ft. )
40
31
24
13
3
RSB07
RAL07
W
t
.

9
3
1

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R060M308
E.P.A. (ft. )
60
48
38
21
11
RSB08
RAL08
W
t
.

9
9
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R060H409
E.P.A. (ft. )
78
67
54
35
21
RSB09
RAL09
W
t
.

1
0
8
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [110]
Short Base
Anchor Base
2
Base Options
R060H510
E.P.A. (ft. )
80
68
56
40
27
RSB10
RAL10
W
t
.

1
1
7
8

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [110]
Short Base
Anchor Base
2
Base Options
S E L F - S UP P OR T I NG T OWE R S - R S L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
181
SS
7
0


T
o
w
e
r
s
18






42
21





45
25






49
28






52
R070L107
E.P.A. (ft. )
23
15
9
-
-
RSB06
RAL06
W
t
.

1
0
7
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R070M208
E.P.A. (ft. )
38
29
21
8
-
RSB08
RAL08
W
t
.

1
1
4
1

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R070M309
E.P.A. (ft. )
58
46
36
21
11
RSB09
RAL09
W
t
.

1
2
3
3

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R070H410
E.P.A. (ft. )
74
60
48
26
13
RSB10
RAL10
W
t
.

1
3
2
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S - R S L
182
2011 ROHN PRODUCTS LLC
8
0


T
o
w
e
r
s
18







45
9
0


T
o
w
e
r
s
21







49
25







52
18








49
21








52
R080L108
E.P.A. (ft. )
21
14
7
-
-
RSB08
RAL08
W
t
.

1
2
8
6

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R080M209
E.P.A. (ft. )
36
26
19
6
-
RSB09
RAL09
W
t
.

1
3
7
8

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R080H310
E.P.A. (ft. )
52
39
26
10
-
RSB10
RAL10
W
t
.

1
4
7
3

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R090L109
E.P.A. (ft. )
19
12
5
-
-
RSB09
RAL09
W
t
.

1
5
2
3

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
R090H210
E.P.A. (ft. )
33
23
13
-
-
RSB10
RAL10
W
t
.

1
6
1
8

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
S E L F - S UP P OR T I NG T OWE R S - R S L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
183
SS
1
0
0


T
o
w
e
r
s
OP T I ONA L ACC E S S OR I E S
3 - 1 1/2
Optional accessories continued on next page.
Grounding Kit shown on page 184.
2
2
2
DISH MOUNT
DM-100
SIDE ARM
S-300
TOP POST KIT
RSLTM12 - FOR SECTION R1 OR R2
RSLTM34 - FOR SECTION R3 OR R4
RSLTM56 - FOR SECTION R5 OR R6
RSLTM78 - FOR SECTION R7 OR R8
RSLTM910 - FOR SECTION R9 OR 10
MOUNTS TO TOP ANGLES PROVIDED WITH
TOWER KIT. INCLUDES: POST, PLATE AND
ATTACHMENT HARDWARE.
18








52
R100S110
E.P.A. (ft. )
17
8
-
-
-
RSB10
RAL10
W
t
.

1
7
6
3

l
b
s
.
Kit No.:
Fastest Mile
[3-sec Gust]
70 [85]
75 [90]
80 [95]
90 [105]
100 [115]
Short Base
Anchor Base
2
Base Options
ACCESSORY SHELF
RASK01
RASK02
RASK03
RASK04
RASK05
2 7/8 O.D.
1 7/8 O.D.
3
2 7/8 O.D.
MOUNTS TO TOWER LEGS AT 5 BELOW TOP.
KIT INCLUDES PLATE AND ATTACHMENT
HARDWARE.
TOP PLATE KIT
RTP01
RTP02
RTP03
RTP04
RTP05
MOUNTS TO TOP ANGLES PROVIDED WITH
TOWER KIT. HOLE PATTERN FITS TB3 (2 O.D.)
AND TB4 (3 O.D.) THRUST BEARINGS OR LRCL
LIGHTNING ROD. KIT INCLUDES PLATE AND
ATTACHMENT HARDWARE.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
SS
S E L F - S UP P OR T I NG T OWE R S - R S L
184
2011 ROHN PRODUCTS LLC
R S L
G R OU N D I N G K I T
Step Bolt Leg
(If Applicable)
Foundation
Ground Lead
Ground Rod
GROUNDING KIT
P/N: RGKF
SAFETY CABLE
SLIDER WITH CARABINEER
TT-WG-500-W/SMC
Tower Height
20 - 50
60 - 100
Part Number
RSL050TT
RSL100TT
TOWER
HEIGHT
20
30
40
50
60
70
80
90
100
PART
NUMBER
RSLSB20
RSLSB30
RSLSB40
RSLSB50
RSLSB60
RSLSB70
RSLST80
RSLSB90
RSLSB100
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SYSTEMS
STEP BOLT KIT
(5/8 X 7)
OP T I ONA L ACC E S S OR I E S
Optional Rev F Grounding Kit.
Fits all RSL Sections.
ANTI-CLIMB PANEL
RAC01
RAC02
RAC03
RAC04
RAC05
RAC06
RAC07
RAC08
RAC09
RAC10
LIGHTNING ROD
LRCL
5 COPPER CLAD, MOUNTS TO TOP
PLATE KIT.
THRUST BEARING
TB3 - SUPPORTS UP TO 2 O.D. MAST.
TB4 - SUPPORTS UP TO 3 O.D. MAST.
MOUNTS TO TOP PLATE KIT.
R S L
F OU N D AT I ON I N F OR MAT I ON
Short Base
Section
RSB02
RSB03
RSB04
RSB05
RSB06
RSB07
RSB08
RSB09
RSB10
Dimensions (in.)
A
84
90
90
96
96
108
114
120
126
B
42
45
45
48
48
54
57
60
63
C
28
29
27
28
26
30
31
32
33
P
10.50
12.50
11.25
11.50
12.00
13.00
12.75
13.50
12.75
Concrete
(Cu. Yds)
7.3
8.3
8.3
9.5
9.5
12.0
13.4
14.8
16.3
No. 7
Bars Req.
32
32
32
36
36
40
40
44
44
Final Grade
6
48
Horizontal Brace used
for Leveling
Embedment
Angles
42
Horizontal #7 bars equally
spaced @ 12 c/c each way
top & bottom.
A
B
Center of
Foundation
and Tower
P
C
S E L F - S UP P OR T I NG T OWE R S - R S L
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
185
SS
See RSL tower kit for appropriate short base or anchor base part numbers. Standard foundations illustrated are for general
information purposes only. Actual details are provided with tower assembly drawings.
A
Leg Stubs
& Anchors
RAL02
RAL03
RAL04
RAL05
RAL06
RAL07
RAL08
RAL09
RAL10
STANDARD FOUNDATION INFORMATION
(Used with short base and anchor base options)
RSL SHORT BASE
ANCHOR BASE
SHORT BASE
(Ordered separately from tower)
Short Base Leg
(3) 3/4dia. x 48
long anchor
bolts
Full-size tower
template
Anchor base option includes: full-size template, anchor bolt
lower template, anchor bolts and leg stubs.
ANCHOR BASE
(Ordered separately from tower)
A
B
A
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S
186
2011 ROHN PRODUCTS LLC
S S V S E L F - S UP P OR T I NG T OWE R S
20 2W
20 3WN
20 4N
20 5N
20 6N
20 7N
20 8N
20 9N
20 10N
20 11N
20 12N
20 13N
20 14N
20 15N
20 16N
Field Bolted
Construction
All-Welded
Construction
Section
Number
Upper Lower
Nominal
Spread Dimension
1WB
2W
3WN
4N
5N
6N
7N
8N
9N
10N
11N
12N
13N
14N
15N
16N
1 - 2
1 - 2
1 - 6
1 - 10
2 - 2
2 - 6
4 - 6 1/4
6 - 6 3/4
8 - 6 3/4
10 - 6 3/4
12 - 7 1/4
14 - 7 7/8
16 - 8 3/8
18 - 8 3/8
20 - 9 3/8
22 - 9 3/8
1 - 2
1 - 6
1 - 10
2 - 2
2 - 6
4 - 6 1/4
6 - 6 3/4
8 - 6 3/4
10 - 6 3/4
12 - 7 1/4
14 - 7 7/8
16 - 8 3/8
18 - 8 3/8
20 - 9 3/8
22 - 9 3/8
24 - 9 3/8
SS
GENERAL USE
The ROHN SSV tower has been in service for over
50 years. The design utilizes standard parts
arranged to create a unique structure. The legs
are tubular with angle braces at the bottom and
solid legs and braces in the top sections. This
tower is used in a variety of applications, from
PCS structures and broadband to security, sports
lighting and more. The SSV has proven to be
one of the industrys most efcient and preferred
structures. All ROHN SSV towers are hot-dip
galvanized, inside and out for corrosion protection.
SSV
STANDARD
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
10 1WB
SS040D70
SS050D70
SS060D70
SS070D70
SS080D70
SS090D70
SS100D70
SS110D70
SS120D70
SS130D70
SS140D70
SS150D70
SS160D70
SS170D70
SS180D70
SS190D70
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
3WN
3WN
4N
4N
5N
5N
6N
6N
7N
7N
8N
8N
9N
9N
10N
10N
SB3
SB3
SB4
SB4
SB5
SB5
-
-
-
-
-
-
-
-
-
-
16.7 (10)
15 (9)
15 (9)
13.3 (8)
13.8 (8)
11.7 (7)
11.7 (7)
10 (6)
10 (6)
9.2 (5.5)
9.2 (5.5)
8.3 (5)
8.3 (5)
7.5 (4.5)
7.5 (4.5)
6.7 (4)
20 (12)
18.3 (11)
18.3 (11)
16.7 (10)
16.7 (10)
15 (9)
15 (9)
14.2 (8.5)
14.2 (8.5)
13.3 (8)
13.3 (8)
12.5 (7.5)
12.5 (7.5)
12.5 (7.5)
12.5 (7.5)
11.7 (7)
S E L F - S UP P OR T I NG S TA NDA R D T OWE R S
4 0 - 1 9 0
7 0 MP H R E V F. [ N O I C E ]
Tower
Assembly
Number
Tower
Height
(ft.)
Top
Section
Base Section
Section
Number
Short
Base P/N
Allowable Projected Area
Tower Top
Rounds (Flats)
30 Below Top
Rounds (Flats)
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
187
SS
General Notes:
1. Standard tower designs are in accordance with approved national standard ANSI/EIA-222-F (no ice).
2. Equivalent flat-plate antenna areas based on EIA RS-222-C, must not exceed the areas shown for flat members.
3. Tower designs assume allowable projected areas are symmetrically placed on the tower.
4. Designs assume one 7/8 line to top and two 7/8 lines to 30 feet below top, one line on each face.
5. All towers are provided with a tapered top.
6. A Rev F grounding kit is provided with each tower.
7. Assembly drawings and standard foundation details are supplied with the tower.
8. Custom designs for site-specific applications are available upon request.
Assy.P/N Tower Section No.
1TT
3TT
4TTN
5TTN
6TT
1W, 1WB, 2W
2WST, 2WB, 3WN
3WNST, 3WNB, 4N
4NST, 4NA, 4WB, 4NC, 5N
5NST, 5NA, 5NB, 5NC, 6C
Tapered Top
14
2 3/8 O.D. Tube
495
564
1012
1077
1441
1505
1863
1927
2449
2513
3173
3248
3952
4017
4816
4880
Tower
Weight
(lbs.)
-
-
-
-
-
-
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
3/4X48
3/4X48
A-Bolts
(12 Req.)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S
188
2011 ROHN PRODUCTS LLC
S E L F - S UP P OR T I NG
S TA N D A R D S E C T I ON S
SS
Bracing Detail for Tapered Sections 6N - 16N
Tubular Legs & Angle Braces
Part No: SB2, SB3, SB4 & SB5
Installed when 2N - 5N sections are
used as tower base.
TYPICAL SHORT BASE
Bracing Detail for Sections 1W - 3WN
Solid Round Legs & Solid Round Braces
Straight and Tapered Sections
available.
Bracing Detail for Straight Sections 6N - 11N
Tubular Legs & Angle Braces
Bracing Detail for Sections 4N & 5N
Solid Round Legs & Solid Round Braces
Straight and Tapered Sections
available.
Anchor bolt confgurations are provided with larger towers.
Pier & Pad
Elevation View
6 Grade
Horizontal Bars
each way
Vert. Bars
equally
spaced
D
Circular
Ties
2
C
A
(square)
Y
Drilled Pier
Elevation View
6
D
Circular
Ties
Vert. Bars
equally
spaced
Section A-A
Y
Y
Vertical Bars
A A
Mat
Elevation View
Tower Axis
and center
of pad
Plan View
Horizontal bars each way,
top and bottom
6
4
W
(square)
Round or Square Pier
Tower Axis
Plan View
Grade Grade
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
189
SS
S E L F - S UP P OR T I NG
S TA N D A R D F OU N D AT I ON S
Tower
Base
Sect.
No.
Pier & Pad
D A C
Dimensions Reqd Conc.
(cu.yds.
3 fdns)
Mat
W
Reqd
Conc.
(cu.yds.)
D Y
Reqd
Conc.
(cu.yds.)
Drilled Pier
1W
2W
3WN
4N
5N
6N
7N
8N
9N
10N
11N
12N
13N
14N
15N
16N
-
-
-
-
-
-
8 - 0
8 - 9
8 - 9
8 - 9
10 - 0
10 - 0
11 - 0
11 - 0
12 - 6
12 - 6
-
-
-
-
-
-
4 - 6
5 - 6
5 - 6
5 - 6
5 - 6
5 - 6
5 - 6
5 - 6
6 - 6
6 - 6
-
-
-
-
-
-
2 - 0
2 - 0
2 - 0
2 - 0
2 - 6
2 - 6
2 - 6
2 - 6
3 - 0
3 - 0
Round Square
-
-
-
-
-
-
6.3
8.7
8.7
8.7
10.8
10.8
11.3
11.3
17.3
17.3
-
-
-
-
-
-
6.9
9.4
9.4
9.4
12.0
12.0
12.7
12.7
19.7
19.7
4 - 0
5 - 6
6 - 9
8 - 0
8 - 9
10 - 3
11 - 6
14 - 3
16 - 0
18 - 3
-
-
-
-
-
-
2.4
4.5
6.8
9.5
11.3
15.6
19.6
30.1
37.9
49. 3
-
-
-
-
-
-
-
-
-
-
-
-
-
18 - 6
16 - 0
16 - 0
21 - 9
21 - 6
22 - 0
22 - 0
27 - 6
27 - 6
-
-
-
-
-
-
-
2 - 6
2 - 6
2 - 6
2 - 6
2 - 6
3 - 0
3 - 0
3 - 6
3 - 6
-
-
-
-
-
-
-
10.4
9.0
9.0
12.2
12.0
17.7
17.7
30.0
30.0
Standard foundations illustrated are for general information purposes only and are based on Rev F normal soil parameters.
Foundation installation details are provided with tower assembly drawings.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S
190
2011 ROHN PRODUCTS LLC
SSV HD SELF- SUPPORTI NG TOWERS
20 3WN
10
3WNB
20 4N
20 5N
20 6N
20 7N
20 8N
20 9NH
20 10NH
20 11N
20 12NH
20 13NH
20 14NH
20 15NH
20 16NH
Field Bolted
Construction
3WN
3WNB
4N
5N
6N
7N
8N
9NH
10NH
11N
12NH
13NH
14NH
15NH
16NH
1 - 6
1 - 10
1 - 10
2 - 2
2 - 6
4 - 6 1/4
6 - 6 3/4
8 - 6 3/4
10 - 6 3/4
12 - 7 1/4
14 - 7 7/8
16 - 8 3/8
18 - 8 3/8
20 - 9 3/8
22 - 9 3/8
1 - 10
1 - 10
2 - 2
2 - 6
4 - 6 1/4
6 - 6 3/4
8 - 6 3/4
10 - 6 3/4
12 - 7 1/4
14 - 7 7/8
16 - 8 3/8
18 - 8 3/8
20 - 9 3/8
22 - 9 3/8
24 - 9 3/8
Section
Number
Upper Lower
Nominal
Spread Dimension
SS
GENERAL USE
The ROHN SSV HD tower has the same features
and utility as the SSV tower, but with Heavy Duty
legs and braces. The heavy duty tower allows for
the structure to support more loading and higher
wind and ice loading. This tower serves the same
applications as the SSV including: PCS, broadband,
security, sports lighting and many others. The
SSV HD also has standard pre-engineered towers
created from standard sections. All ROHN SSV
towers are hot-dip galvanized, inside and out for
corrosion protection.
SSV
HEAVY DUTY
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
All-Welded
Construction
Tapered Top
14
2 3/8 O.D. Tube
S E L F - S UP P OR T I NG HE AV Y DUT Y S TA NDA R D T OWE R S
4 0 - 1 9 0
9 0 MP H R E V. F [ N O I C E ]
Tower
Assembly
Number
Tower
Height
(ft.)
Top
Section
Base Section
Section
Number
Short
Base P/N
Allowable Projected Area
Tower Top
Rounds (Flats)
30 Below Top
Rounds (Flats)
SS040D90
SS050D90
SS060D90
SS070D90
SS080D90
SS090D90
SS100D90
SS110D90
SS120D90
SS130D90
SS140D90
SS150D90
SS160D90
SS170D90
SS180D90
SS190D90
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
4N
5N
5N
6N
6N
7N
7N
8N
8N
9NH
9NH
10NH
10NH
11N
11N
12NH
SB4
SB5
SB5
-
-
-
-
-
-
-
-
-
-
-
-
-
16.7 (10)
16.7 (10)
14.2 (8.5)
14.2 (8.5)
12.5 (7.5)
12.5 (7.5)
10 (6)
10 (6)
8.3 (5)
8.3 (5)
6.7 (4)
6.7 (4)
5.8 (3.5)
5.8 (3.5)
5 (3)
5 (3)
20 (12)
20 (12)
17.5 (10.5)
17.5 (10.5)
15.8 (9.5)
15.8 (9.5)
13.3 (8)
13.3 (8)
11.7 (7)
11.7 (7)
10 (6)
10 (6)
8.3 (5)
8.3 (5)
7.5 (4.5)
7.5 (4.5)
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
191
SS
General Notes:
1. Standard tower designs are in accordance with approved national standard ANSI/EIA-222-F (no ice).
2. Equivalent flat-plate antenna areas based on EIA RS-222-C, must not exceed the areas shown for flat members.
3. Tower designs assume allowable projected areas are symmetrically placed on the tower.
4. Designs assume one 7/8 line to top and two 7/8 lines to 30 feet below top, one line on each face.
5. All towers are provided with a tapered top.
6. A Rev F grounding kit is provided with each tower.
7. Assembly drawings and standard foundation details are supplied with the tower.
8. Custom designs for site-specific applications are available upon request.
Assy.P/N Tower Section No.
1TT
3TT
4TTN
5TTN
6TT
1W, 1WB, 2W
2WST, 2WB, 3WN
3WNST, 3WNB, 4N
4NST, 4NA, 4WB, 4NC, 5N
5NST, 5NA, 5NB, 5NC, 6C
Tower
Weight
(lbs.)
853
1198
1282
1620
1704
2206
2290
2941
3025
3829
3913
4810
4894
5712
5796
8045
A-Bolts
(12 Req.)
-
-
-
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
3/4X48
3/4X48
7/8X60
7/8X60
7/8X60
TYPICAL SHORT BASE
Part No: SB2, SB3, SB4 & SB5
Installed when 2N - 5N sections are
used as tower base.
Bracing Detail for Sections 1W - 3WN
Solid Round Legs & Solid Round Braces
Straight and Tapered Sections
available.
Bracing Detail for Straight Sections 6N - 11N
Tubular Legs & Angle Braces
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S
192
2011 ROHN PRODUCTS LLC
S E L F - S UP P OR T I NG
H E AV Y D U T Y S E C T I ON S
SS
Bracing Detail for Sections 4N & 5N
Solid Round Legs & Solid Round Braces
Straight and Tapered Sections
available.
Bracing Detail for Tapered Sections 6N - 16NH
Tubular Legs & Angle Braces
Anchor bolt confgurations are provided with larger towers.
S E L F - S UP P OR T I NG T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
193
SS
Tower
Base
Sect.
No.
Pier & Pad
D A C
Dimensions Reqd Conc.
(cu.yds.
3 fdns)
Mat
W
Reqd
Conc.
(cu.yds.)
D Y
Reqd
Conc.
(cu.yds.)
Drilled Pier
1W
2W
3WN
4N
5N
6N
7N
8N
9NH
10NH
11N
12NH
13NH
14NH
15NH
16NH
Round Square
-
-
-
-
-
-
8 - 0
8 - 9
9 - 0
9 - 0
10 - 0
11 - 0
12 - 0
12 - 0
13 - 0
13 - 0
-
-
-
-
-
-
4 - 6
5 - 6
5 - 6
5 - 6
5 - 6
5 - 6
6 - 3
6 - 3
7 - 3
7 - 3
-
-
-
-
-
-
2 - 0
2 - 0
2 - 0
2 - 0
2 - 6
2 - 6
3 - 0
3 - 0
3 - 0
3 - 0
-
-
-
-
-
-
6.3
8.7
8.8
8.8
10.8
11.3
16.3
16.3
19.9
19.9
-
-
-
-
-
-
6.9
9.4
9.5
9.5
12.0
12.7
18.5
18.5
22.4
22.4
4 - 0
5 - 6
6 - 9
8 - 0
8 - 9
10 - 3
11 - 6
14 - 3
16 - 0
18 - 3
-
-
-
-
-
-
2.4
4.5
6.8
9.5
11.3
15.6
19.6
30.1
37.9
49. 3
-
-
-
-
-
-
-
-
-
-
-
-
-
18 - 6
19 - 6
19 - 6
21 - 9
22 - 9
25 - 0
25 - 0
30 - 0
30 - 0
-
-
-
-
-
-
-
2 - 6
2 - 6
2 - 6
2 - 6
3 - 0
3 - 6
3 - 6
4 - 0
4 - 0
-
-
-
-
-
-
-
10.4
10.9
10.9
12.2
18.3
27.3
27.3
42.6
42.6
S E L F - S UP P OR T I NG
H E AV Y D U T Y S TA N D A R D F OU N D AT I ON S
Pier & Pad
Elevation View
6 Grade
Horizontal Bars
each way
Vert. Bars
equally
spaced
D
Circular
Ties
2
C
A
(square)
Y
Drilled Pier
Elevation View
6
D
Circular
Ties
Vert. Bars
equally
spaced
Section A-A
Y
Y
Vertical Bars
A A
Mat
Elevation View
Tower Axis
and center
of pad
Plan View
Horizontal bars each way,
top and bottom
6
4
W
(square)
Round or Square Pier
Tower Axis
Plan View
Grade Grade
Standard foundations illustrated are for general information purposes only and are based on Rev F normal soil parameters.
Foundation installation details are provided with tower assembly drawings.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S - S S MW
194
2011 ROHN PRODUCTS LLC
S S MW S E L F - S UP P OR T I NG T OWE R S
20 B
20 C
20 E
20 F
20 G
20 H
20 J
20 K
20 M
30 N
20 L
30 P
30 Q
30 R
30 S
30 T
Section
Number
Upper Lower
Nominal
Spread Dimension
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
8 - 6 1/2
8 - 6 1/2
10 - 7
12 - 7 1/2
14 - 11 1/2
17 - 5 1/2
19 - 11 1/2
22 - 6 1/2
25 - 0 1/2
27 - 6 1/2
30 - 0 1/2
32 - 6 1/2
36 - 3 1/2
40 - 2 1/8
43 - 11 1/8
47 - 8 1/8
51 - 5 1/8
8 - 6 1/2
10 - 7
12 - 7 1/2
14 - 11 1/2
17 - 5 1/2
19 - 11 1/2
22 - 6 1/2
25 - 0 1/2
27 - 6 1/2
30 - 0 1/2
32 - 6 1/2
36 - 3 1/2
40 - 2 1/8
43 - 11 1/8
47 - 8 1/8
51 - 5 1/8
55 - 2 1/8
20 D
SS
GENERAL USE
The ROHN SSMW tower is a unique design using
a K-Brace system with horizontal plan bracing to
allow free standing towers to reach heights to
900. The SSMW is designed with pipe legs and
pipe braces with fanges at each end for connection.
The SSMW tower design can be used in conjunction
with the SSV tower. All SSMW towers are hot-dip
galvanized, inside and out for corrosion protection.
SSMW
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
S E L F - S UP P OR T I NG
S S MW S E C T I ON S
S E L F - S UP P OR T I NG T OWE R S - S S MW
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
195
SS
Typical section assembly detail for sections B, C & D.
Section E, F, G, H & J are identical except
for the number of bays of bracing.
Typical section assembly
detail for sections K, L & M.
Typical section assembly
detail for sections N, P, Q,
R, S & T.
Secondary horizontal
sub-bracing are used on
sections Q, R, S & T.
Bracing splice
connections are
used on sections
Q through T.
SSMW SECTIONS
Sections are designed for many different
sizes of braces and legs.
View A-A
View B-B
A
A
B
B
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S - S S V S R
196
2011 ROHN PRODUCTS LLC
SSVSR SELF- SUPPORTI NG TOWERS
20 1W
20 2W
20 3WN
20 4N
20 5N
20 6SR
20 7SR
20 8SR
20 9SR
20 11SR
20 12SR
20 13SR
20 14SR
20 15SR
20 16SR
All Bolted
Construction
All Welded
Construction
Section
Number
Upper Lower
Nominal
Spread Dimension
1W
2W
3WN
4N
5N
6SR
7SR
8SR
9SR
10SR
11SR
12SR
13SR
14SR
15SR
16SR
1 - 2
1 - 2
1 - 6
1 - 10
2 - 2
2 - 6
4 - 6 1/4
6 - 6 3/4
8 - 6 3/4
10 - 6 3/4
12 - 7 1/4
14 - 7 7/8
16 - 8 3/8
18 - 8 3/8
20 - 9 3/8
22 - 9 3/8
1 - 2
1 - 6
1 - 10
2 - 2
2 - 6
4 - 6 1/4
6 - 6 3/4
8 - 6 3/4
10 - 6 3/4
12 - 7 1/4
14 - 7 7/8
16 - 8 3/8
18 - 8 3/8
20 - 9 3/8
22 - 9 3/8
24 - 9 3/8
20 10SR
SS
GENERAL USE
The ROHN SSVSR tower is similar in design to the
ROHN SSV tower, but uses solid round legs instead
of tubular legs. The SSVSR tower gives the
versatility to switch to a solid leg, if desired. The
standard side arms, dish mounts, ladders and
waveguide supports that are used on the SSV
tower can be used on the SSVSR tower. All SSVSR
towers are hot-dip galvanized for corrosion
protection.
SSVSR
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
Part No: SB2, SB3, SB4 & SB5
Installed when 2N - 5N sections are
used as tower base.
Anchor bolt confgurations are provided with larger towers.
Bracing Detail for Sections 1W - 3WN
Solid Round Legs & Solid Round Braces
Straight and Tapered Sections
available.
Bracing Detail for Straight Sections 6SR & 11SR
Solid Round Legs & Angle Braces
S E L F - S UP P OR T I NG T OWE R S - S S V S R
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
197
SS
S E L F - S UP P OR T I NG
S OL I D R OU N D L E G S E C T I ON S
SSVSR SECTIONS
Sections are designed for many different
sizes of braces and legs.
Bracing Detail for Sections 4N & 5N
Solid Round Legs & Solid Round Braces
Straight and Tapered Sections
available.
Bracing Detail for Tapered Sections 6SR - 16SR
Solid Round Legs & Angle Braces
TYPICAL SHORT BASE
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S E L F - S UP P OR T I NG T OWE R S - R S
198
2011 ROHN PRODUCTS LLC
Section
Number
Upper Lower
Nominal
Spread Dimension
RSS06
RST08
RST10
RST12
RST15
RST18
RST21
RST24
RST27
6
6
8
10
12
15
18
21
24
6
8
10
12
15
18
21
24
27
RS SELF- SUPPORTI NG TOWERS
30 RST27
30 RST24
30 RST21
30 RST18
30 RST15
20 RST12
20 RST10
20 RST08
20 RSS06
20 RSS06
SS
20 RSS06
GENERAL USE
The ROHN RS tower is a unique solid round leg
tower that uses angle braces in an X-Brace pattern.
The RS tower is custom designed with standard
components to shorten lead times. All RS towers
are hot-dip galvanized for corrosion protection.
RS
Per Rev G requirements, any structure greater than 10 requires a climber
safety device. Please contact ROHN for ordering information.
5 RSS06
S E L F - S UP P OR T I NG
R S S E C T I ON S
RSS 20 Straight Section
Solid Round Legs & Angle Braces
RST 20 Tapered Section
Solid Round Legs & Angle Braces
RST 30 Tapered Section
Solid Round Legs & Angle Braces
S E L F - S UP P OR T I NG T OWE R S - R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
199
SS
RS SECTIONS
Sections are designed for many different
sizes of braces and legs.
RST 30 Base Section
Solid Round Legs & Angle Braces
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
200
NOT E S
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
3 AND 6 SI DE ARMS, STRAI GHT/ TAPERED TOWER SECTI ONS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
202
SA32PL
SA325PL
SA33PL
SA335PL
SA34PL
SA35PL
SA36PL
SA38PL
SA310PL
SA312PL
2.38
2.88
3.50
4.00
4.50
5.56
6.63
8.63
10.75
12.75
Notes:
1. Standard tiebacks to the supporting structure are available for towers with 8.5 ft. or less face width.
2. To order tiebacks, include (1TB) for one or (2TB) for two after side arm assembly part number.
3. Custom side arms and tiebacks are available upon request.
4. Check for leg size to determine assembly number required.
Tower Leg O.D.
2.38 - 4.50
5.56 - 6.63
3Side Arm 6Side Arm
SA324A
SA356A
SA624A
SA656A
Tower Leg O.D. 3Side Arm 6Side Arm
SA62PL
SA625PL
SA63PL
SA635PL
SA64PL
SA65PL
SA66PL
SA68PL
SA610PL
SA612PL
3
Tower Leg
Tower Leg
2.38 O.D. x 5 Long
Mounting Tube
2.38 O.D. x 5 Long
Mounting Tube
6
3 Side Arm 6 Side Arm
All side arms are hot-dip galvanized and include all hardware to attach mount to tower.
UNI V E R S A L K I T S L E G S P E C I F I C K I T S
L E G DI S H MOUNT S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
203
2011 ROHN PRODUCTS LLC
A
Tower Leg
Tower Leg
4.50 O.D. x 6 - 8 Long
Standard Mounting Tube
Description
Fits leg sizes 2.38 O.D. - 4.50 O.D.
Fits leg sizes 5.50 O.D. - 6.63 O.D.
Part No.
S24HUM
S56HUM
Straight Leg
Description
Fits leg sizes 2.38 O.D. - 4.50 O.D.
Fits leg sizes 5.50 O.D. - 6.63 O.D.
Part No.
T24HUM
T56HUM
Tapered Leg
Straight Tapered
Leg O.D.
2.38
2.88
3.50
4.00
4.50
5.50
6.63
Part No.
VY1949A
VY1950A
VY1951A
VY1952A
VY1953A
VY1954A
VY1955A
Kits include (1) clip with
u-bolts. Some dishes
require (2) tie-backs.
LEG TI E- BACK PLATE KI T
9/16, 11/16 and
13/16dia. holes
provided.
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
204
Length
5
6
8
10
12
Part No.
TMT6LL05
TMT6LL06
TMT6LL08
TMT6LL10
TMT6LL12
TS 6 x 6 x 3/16
Step 1. Select Tie-Back Tube Size & Length

Length
5
6
8
10
12
Part No.
TMT6L05
TMT6L06
TMT6L08
TMT6L10
TMT6L12
TS 6 x 6 x 1/4
Length
5
6
8
10
12
Part No.
TMT6H05
TMT6H06
TMT6H08
TMT6H10
TMT6H12
TS 6 x 6 x 3/8
Leg O.D.
1.90 - 5.56
6.63 - 8.63
Part No.
VY2911A
VY2912A
4 Tube
Leg O.D.
1.90 - 5.56
6.63 - 8.63
10.75 - 12.75
Part No.
VY4457A
VY4458A
VY4459A
6 Tube
Step 2. Select Angle Bracket Kit
Based on leg O.D.
Leg O.D.
1.90 - 2.38
2.88
3.50
4.00
4.50
5.56
6.63
8.63
10.75
12.75
Part No.
JR83AW4
JR84AW4
JR88AW4
JR89AW4
JR85AW4
JR86AW4
JR87AW4
JR90SAW4
JR110AW4
JR120AW4
Step 3. Select U-Bolt Kit
Based on leg O.D.
Tube Size
4
6
Part No.
AP34T4
AP6T2
Step 4. Select Additional Tie-Back Plate
Kits (if required).
T I E - B AC K A S S E MB L I E S
[ F o l l o w s t e p s 1 - 4 t o o r d e r ]
All mounts and tie-back assemblies are hot-dip
galvanized and include all hardware to attach
mount to tower.
Step 2:
Select angle bracket
kit (includes (2)
brackets).
Step 1:
Select tie-back tube.
Step 3:
Select u-bolt
kit (includes
(4) u-bolts).
Step 4:
Select additional tie-back
plate kits, if required.
Optional Position
(1) Tie-back plate kit
provided with mount,
9/16, 11/16 and 13/16
dia. holes provided.
FAC E DI S H MOUNT S
[ F OL L OW S T E P S 1 - 3 T O OR D E R ]
ORDERING INFORMATION:
Tube Description
4.50 O.D. x 5
4.50 O.D. x 6.67
4.50 O.D. x 10
Part No.
DMF4T050S
DMF4T068S
DMF4T100S
Straight Leg
Step 1. Select Mounting Tube Length (4.50 O.D. x 0.237 wall)
Tube Description
4.50 O.D. x 5
4.50 O.D. x 6.67
4.50 O.D. x 10
Part No.
DMF4T050T
DMF4T068T
DMF4T100T
Tapered Leg
Leg O.D.
1.90 - 2.38
2.88
3.50
4.00
4.50
5.56
Part No.
JR83AW4
JR84AW4
JR88AW4
JR89AW4
JR85AW4
JR86AW4
Straight or Tapered Legs
Step 2. Select Upper and Lower Connections
Because leg O.D. may be different at upper and lower connections,
select one part number for upper and one part number for lower.
Length
5
6
8
10
Part No.
TMT4L05
TMT4L06
TMT4L08
TMT4L10
4 x 4 x 11GA
Step 3. Select Square Tube Supports
Based on required strength and length. Select (1) part number for upper
support and (1) part number for lower support.
Length
5
6
8
10
Part No.
TMT4H05
TMT4H06
TMT4H08
TMT4H10
4 x 4 x .25
Length
5
6
8
10
Part No.
TMT4XH05
TMT4XH06
TMT4XH08
TMT4XH10
4 x 4 x .375
Upper
Connection
Lower
Connection
Upper
Connection
Lower
Connection
Tower
Leg
Tower
Leg
Step 3:
Select upper and lower
square tube supports
(2) Brackets are included with each kit.
Tapered Legs
Step 1:
Select
Mounting
Tube
Plan View
Straight Legs
Step 1:
Select
Mounting
Tube
Step 2:
Select upper
and lower
connections
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
205
2011 ROHN PRODUCTS LLC
A
Step 2:
Select upper
and lower
connections
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
206
FAC E MOUNT K I T S
LI GHTWEI GHT FACE MOUNT KI TS
Mounting Tube
2.38 O.D. x 0.154 wall x 5 Long
4.50 O.D. x 0.237 wall x 5 Long
Part No.
FM35NU2
FM35NU4
FITS MIN. FACE WIDTH 18 TO MAX. FACE WIDTH 30,
LEG SIZES 1 TO 1 3/4 O.D.
Tower
Leg
2.38or
4.50O.D.
Mounting
Tube
Face dish mounts are hot-dip galvanized and include all required
hardware to attach mount to tower.
Straight or Tapered Legs
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
207
2011 ROHN PRODUCTS LLC
A
Face Spread
8 Max.
8 Min. - 14 Max.
Part No.
KY2016A
KY1993A
Frame Support Assembly
Straight Leg
SECTOR MOUNT ORDERING INFORMATION
Step 1. Select frame P/N based
on tower face spread.
Mast
2.38O.D. (0.154 wall) x 5 Long
2.38O.D. (0.218wall) x 8 Long
Part No.
VY4935A
VY4935A8
Antenna Mast Kit
Step 2. Select antenna mast kits (2 min.)
(1) Kit per mast tube
Standard mount ships
with (1) tie back.
3 5
20 *
(Qty. is for (1) sector only)
Face Spread
8 Max.
8 Min. - 14 Max.
Part No.
KY2006A
KY2015A
Frame Support Assembly
Tapered Leg
Leg O.D.
2.38 O.D.
2.88 O.D.
3.50 O.D.
4.00 O.D.
4.50 O.D.
5.56 O.D.
6.63 O.D.
8.63 O.D.
Part No.
KY1994A
KY1995A
KY1996A
KY1997A
KY1998A
KY1999A
KY2000A
KY2001A
Leg Mounting Kit
Straight Leg
Step 3. Select leg mounting kit.
Leg O.D.
2.38 O.D.
2.88 O.D.
3.50 O.D.
4.00 O.D.
4.50 O.D.
5.56 O.D.
6.63 O.D.
8.63 O.D.
Part No.
KY2007A
KY2008A
KY2009A
KY2010A
KY2011A
KY2012A
KY2013A
KY2014A
Leg Mounting Kit
Tapered Leg
* Horizontal boom also available
in 12 - 18 lengths (2 increments).
Add desired width to end of frame
support part number if less than
a 20 width is desired
Example:
For an 18 width, order part number
KY2016A18. (Refer to table for step 1.)
Side View
S E C T OR MOUNT
[ F OL L OW S T E P S 1 - 3 T O OR D E R ]
Step 1:
Select frame P/N from
table below.
Step 2:
Select antenna mast from
table below.
Step 3:
Select leg
mounting kit
from table
below.
6

-

1

Sector mounts are hot-dip galvanized


and include all required hardware to
attach mount to tower.
Face Spread
(See Step 1)
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
R OT OR P L AT E A S S E MB L I E S
F OR R OH N S TA N D A R D S E L F - S U P P OR T I N G T OWE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
208
4 - 6
Mast Pipe
TB3 or TB4
Top Plate to
Mount TB3
or TB4 Thrust
Bearing
Tower Axis
1W / 2W
Tower Leg
P/N: VU479A
NOTES:
1. All plates are 3/8 thick
2. Rotor top plates are pre-drilled to fit a variety of rotors.
3. Rotor plate assembly includes top plate and rotor plate.
4. Mast pipe, rotor and thrust bearing must be ordered separately.
Mast Pipe
TB3 or TB4
Top Plate to
Mount TB3 or TB4
Thrust Bearing
Tower Axis
3WN Tower
Leg
3 WN 3 WN S T / 3 WN B
5 - 0
Mast Pipe
TB3 or TB4
Top Plate to
Mount TB3
or TB4 Thrust
Bearing
Tower Axis
3WNST /
3WNB
Tower
Leg
P/N: VU140 P/N: VU474A
1 W / 2 W
Rotor plate accessories are hot-dip galvanized and include all required hardware to attach assemblies to tower.
Climbing Harness
S A F E T Y & C L I MB I NG
G - S E R I E S T OWE R S | P OL E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
209
2011 ROHN PRODUCTS LLC
A
SAFETY CABLE - TOWERS
SAFETY CABLE - POLES
Description
25 - Pole
50 - Pole
100 - Pole
150 - Pole
200 - Pole
250 - Pole
Step Anchor Bracket
Additional 4 Stud
Cable Guide
Cable (ft.)
35
60
110
160
210
260
-
-
Part No.
TT025TSP
TT050TSP
TT100TSP
TT150TSP
TT200TSP
TT250TSP
TTSBAB
TT115317-4
# Guides
1
2
4
6
8
10
-
-
Safety Cable Slider
with Carabineer
Description Part Number
50 - 25G tower
100 - 25G tower
150 - 25G tower
200 - 25G tower
TT05025
TT10025
TT15025
TT20025
50 - 45G/55G tower
100 - 45G/55G tower
150 - 45G/55G tower
200 - 45G/55G tower
250 - 45G/55G tower
300 - 45G/55G tower
350 - 45G/55G tower
TT0504555
TT1004555
TT1504555
TT2004555
TT2504555
TT3004555
TT3504555
Description Part Number
50 - 65G tower
100 - 65G tower
150 - 65G tower
200 - 65G tower
250 - 65G tower
300 - 65G tower
350 - 65G tower
400 - 65G tower
450 - 65G tower
500 - 65G tower
TT05065
TT10065
TT15065
TT20065
TT25065
TT30065
TT35065
TT40065
TT45065
TT50065
Description Part Number
4-D Ring Climbing Harness
Professional Harness
Safety Cable Slider
TTFBH-4D
TTFBH-C/P
TT-WG-500-W/SMC
Description Part Number
50 Climbing Ladder
100 Climbing Ladder
150 Climbing Ladder
200 Climbing Ladder
250 Climbing Ladder
300 Climbing Ladder
TT050LAD
TT100LAD
TT150LAD
TT200LAD
TT250LAD
TT300LAD
Description Part Number
SAFETY CABLE SYSTEM FOR
CLIMBING LADDERS - TOWERS
HARNESS & SLIDER
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
C L I MB I NG L A DDE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
210
C ON F I G U R AT I ON S
5/8 Dia.
Ladder
Rung
.25 x 1.50
Side Rails
STANDARD LADDER
NL10 - 10 ladder
NL20 - 20 ladder
15 O.C.
3/4 Dia.
Ladder
Rung
.25 x 2.50
Side Rails
HEAVY DUTY LADDER
HL161A - 10 ladder
HL162A - 20 ladder
12 O.C.
Face Mounted Inside Corner Mounted Leg Mounted
Notes:
1. Ladders are available for most ROHN standard tower sections.
2. All ROHN climbing devices are indended for use by professional (competent climbers) only.
3. Specify ladder type and confguration when ordering.
4. Custom confgurations and mounting options available.
5. A safety climb system is required for all structures greater than 10 in height.
Part number for ladder section only. Mounting kit must be ordered separately.
WAV E GUI DE L A DDE R
FA C E MOU N T E D 9 - H OL E
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
211
2011 ROHN PRODUCTS LLC
A
Waveguide Ladder Elevation
WL20F93KD
20 Long Waveguide Ladder (3 rung spacing)
WL20F94KD
20 Long Waveguide Ladder (4 rung spacing)
WL10F93KD
10 Long Waveguide Ladder (3 rung spacing)
WL10F94KD
10 Long Waveguide Ladder (4 rung spacing)
ORDERING INFORMATION
Notes:
1. Waveguide ladder may be moved horizontally for the proper alignment.
2. Waveguide ladder may be mounted inside or outside of tower as required.
Ladder Rail
Bolt Assembly
J-Bolt Assembly
Diagonal
Tower Brace
Ladder Rail
Bolt Assembly
7/16 Dia. Holes
(9 Per Rung)
3/4 Dia. Holes
(9 Per Rung)
Ladder Rail
Ladder
Attachment
Clip
Diagonal Tower
Brace
1.9
3 or 4
5 Max. Angle
3/8 Max. Thickness
2 1/2
WAV E GUI DE L A DDE R
FA C E MOU N T E D 1 2 - H OL E
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
212
Waveguide Ladder Elevation
WL20F123KD
20 Long Waveguide Ladder (3 rung spacing)
WL20F124KD
20 Long Waveguide Ladder (4 rung spacing)
WL10F123KD
10 Long Waveguide Ladder (3 rung spacing)
WL10F124KD
10 Long Waveguide Ladder (4 rung spacing)
ORDERING INFORMATION
Notes:
1. Waveguide ladder may be moved horizontally for the proper alignment.
2. Waveguide ladder may be mounted inside or outside of tower as required.
Ladder Rail
Bolt Assembly
J-Bolt Assembly
Diagonal
Tower Brace
Ladder Rail
Bolt Assembly
7/16 Dia. Holes
(12 Per Rung)
3/4 Dia. Holes
(12 Per Rung)
Ladder Rail
Ladder
Attachment
Clip
Diagonal Tower
Brace
2.6
3 or 4
5 Max. Angle
3/8 Max. Thickness
2 1/2
WAV E GUI DE L A DDE R
FA C E MOU N T E D 1 5 - H OL E
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
213
2011 ROHN PRODUCTS LLC
A
Waveguide Ladder Elevation
WL20F153KD
20 Long Waveguide Ladder (3 rung spacing)
WL20F154KD
20 Long Waveguide Ladder (4 rung spacing)
WL10F153KD
10 Long Waveguide Ladder (3 rung spacing)
WL10F154KD
10 Long Waveguide Ladder (4 rung spacing)
ORDERING INFORMATION
Notes:
1. Waveguide ladder may be moved horizontally for the proper alignment.
2. Waveguide ladder may be mounted inside or outside of tower as required.
Ladder Rail
Bolt Assembly
J-Bolt Assembly
Diagonal
Tower Brace
Ladder Rail
Bolt Assembly
7/16 Dia. Holes
(15 Per Rung)
3/4 Dia. Holes
(15 Per Rung)
Ladder Rail
Ladder
Attachment
Clip
Diagonal Tower
Brace
2.8
3 or 4
5 Max. Angle
3/8 Max. Thickness
2 1/4
WAV E GUI DE B R AC K E T S
3 - H OL E
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
214
Waveguide Bracket Elevation
KY2041A
ORDERING INFORMATION
Notes:
1. Kit includes (1) bracket with required mounting hardware.
2. Assembly used for mounting to 3/4 - 2 1/4 O.D. legs.
3. (5) KY2041A required per 20 of tower for 4 O.C. spacing.
KY2041A
(3) 7/16 holes
(3) 3/4 holes
2 1/4
WAV E GUI DE B R AC K E T S
8 - H OL E ( 8 0 S E R I E S )
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
215
2011 ROHN PRODUCTS LLC
A
WAF801213
(Horizontals)
Order 1 per 15 or 20 section
WAF801214
(2 Diagonals)
Order 3 per 15 section
Order 4 per 20 section
WAF801215
(1 3/4 Diagonals)
Order 3 per 15 section
Order 4 per 20 section
ORDERING INFORMATION
Bolt Assembly
Diagonal
Waveguide
Brace Bracket
Horizontal Waveguide
Brace Bracket
Bolt Assembly
Bolt Assembly
Horizontal
Waveguide
Brace Bracket
U-Bolt Assembly
Diagonal
Waveguide
Brace Bracket
WAF801211
(Horizontals)
Order 1 per 15 or 20 section
WAF801212
(Diagonals)
Order 3 per 15 section
Order 4 per 20 section
ORDERING INFORMATION
7/16 hole (12 Holes Per Bracket)
3/4 hole (12 Holes Per Bracket)
Diagonal Tower
Brace (TYP)
Tower Leg
(TYP)
Standard ROHN
brace with
pre-punched
holes for bracket
attachment
2 1/4Spacing
Tubular Bracing
1 1/2 Diameter
Angle Bracing
1 3/4 x 3/16
2 x 1/4
Tower Leg
(TYP)
NOTE: These assemblies may be mounted on the inside or outside face of the tower.
WAV E GUI DE B R AC K E T S
1 5 - H OL E ( 9 0 S E R I E S )
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
216
WAF901521
Angle Waveguide Support
& Bolt Assembly
ORDERING INFORMATION
Order (1) assembly part number WAF901521 for each diagonal brace bay
that waveguides cross in a section. (Ex. (5) WAF901521 for a 20 tower
section, (3) WAF901521 for a 12 tower section, etc.). This assembly may
be mounted on outside of tower as shown or on inside as required.
Diagonal Tower
Brace
Diagonal Waveguide
Brace Bracket
7/16 Holes @ 2.25 Horizontal
Spacing (14 Holes Per Support)
Tower Leg
3/4 Holes @ 2.25 Horizontal
Spacing (15 Holes Per Support)
Bolt Assembly
2 Spacing
Angle Bracing
HE AV Y DUT Y WAV E GUI DE B R I DGE
1 0 S I N G L E / D OU B L E
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
217
2011 ROHN PRODUCTS LLC
A
WGBS2410
Single Wide Bridge
2 Posts, 1 Bridge Panel (24W x10 L)
(3) Trapeze Units
WGBD2410
Double Bridge
2 Posts, 2 Bridge Panels (24W x 10 L, each)
(6) Trapeze Units
ORDERING INFORMATION
Notes:
1. Waveguide bridge is not designed to support personnel or equipment.
Ground Line
Support Post
4 O.D. Tube
18 Long
Diagonal
Brace Angle
Panel
Support
Angle
10
12 Max
4 Min. Into
Undisturbed
Soil
3 Into Gravel
6 Gravel Drain
7
Space as Required
(3 Trapeze Units
provided with each
Waveguide Bridge)
(8) 7/16 O Holes
(9) 3/4 O Holes
2 1/4 O.C. Hole Spacing
Units bolt
together
in field
24
10
Single
Double
Waveguide Panels
Threaded
Rod Hangers
Trapeze
A
GE NE R A L T OWE R & S I T E ACC E S S OR I E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
218
L I GHT DUT Y WAV E GUI DE B R I DGE
1 0 S I N G L E / D OU B L E
WGBS121014
Single Wide Bridge
2 Posts, 1 Bridge Panel (12W x10 L)
(3) Trapeze Units
WGBD121014
Double Bridge
2 Posts, 2 Bridge Panels (12W x 10 L, each)
(6) Trapeze Units
ORDERING INFORMATION
Notes:
1. Waveguide bridge is not designed to support personnel or equipment.
Ground Line
Support Post
4 O.D. Tube
14 Long
10
10 Max
4 Min. Into
Undisturbed
Soil
3Into Gravel
6 Gravel Drain
7
12
10
(3) 7/16 O Holes
(4) 3/4 O Holes
2 1/4 O.C. Hole Spacing
Single
Double
Units bolt
together
in field
Waveguide Panels
Trapeze
Panel
Support
Angle
Threaded
Rod Hangers
Space as Required
(3 Trapeze Units
provided with each
Waveguide Bridge)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
DI R E C T E MB E D P OL E S
DI R E C T E MB E D P OL E
S TA N D A R D D E S I G N S
220
2011 ROHN PRODUCTS LLC
180
270 90
Safety Climb Support Bracket
(Safety Cable System Ordered Separately)
0
C
D
A B
PORT ORIENTATIONS
8 Separation
Splice
4 3
Aggregate
Backfill
2
Embedment
Bearing Plate
(Allows Drainage)
Port A
Port B
Port C
Port D
Cap Plate
(3) Jacking Lugs
Pole Height
Above Grade
6 Gravel Base
1 3
GENERAL USE
ROHN Di rect Embed Pol es mi ni mi ze si te
requirements, lowering lease rates and acquisition
costs. They are designed for rapid installation,
meeting the demands of todays dynamic
communication environments. Whether you are
supporting broadband, PCS, security or other
lightweight systems, ROHN Tapered Steel Poles
ofer extremely efcient designs.
FEATURES
Completely hot-dip galvanized after fabrication
Fast, easy installation
Designed for applications with stringent defection
requirements
Internal routing of transmission lines
Each pole ships with the following:
Assembly Drawings and Standard Foundation Details
(4) 5 x 7 Ports with (2) port covers
(3) Jacking Lugs on each side of splices
(3) Ground attachment clips
(1) Vented cap plate
(1) Bearing plate welded to bottom
Safety Climb Support Brackets
(1) Safety warning sign
(1) Pole ID tag
Attachment clips for optional step bolts
Optional items are available and may be ordered
separately. Please see accessories on page 225.
Custom designs available for any height or
application.
DIRECT EMBED
POLES
Grade
Per Rev G requirements, any structure greater than 10 requires a
climber safety device. Please see page 225 for ordering information.
Ground Attachment Clips
221
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
DI R E C T E MB E D P OL E S
Part Number for
ordering direct
embed poles
Sway at TIA
operational
wind speed
Total effective
projected area
of antennas, mounts
and lighting allowed
on pole (see pg. 226)
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
69
52
38
27
19
13
3
49
49
38
27
19
13
2
29
29
29
27
19
13
4
110
80
59
44
32
24
3
108
80
59
44
32
24
2
68
68
59
44
32
24
4
170
126
95
74
57
45
3
170
126
95
74
57
45
2
143
126
95
74
57
45
3
0

EMBEDMENT DEPTH DIA. 10 2.5 DEPTH DIA. 11 2.5 DEPTH DIA. 13 3.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP30HA DEP30MA DEP30LA
Depth and diameter of
embedment for gravel
backfill. Installation
adds 6 to the depth
for gravel base
B UY E R S GUI DE
L OA DI NG C HA R T S
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
69
52
38
27
19
13
3
49
49
38
27
19
13
2
29
29
29
27
19
13
4
110
80
59
44
32
24
3
108
80
59
44
32
24
2
68
68
59
44
32
24
4
170
126
95
74
57
45
3
170
126
95
74
57
45
2
143
126
95
74
57
45
4
0

EMBEDMENT DEPTH DIA. 12 2.5 DEPTH DIA. 13 2.5 DEPTH DIA. 15 3.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP40HA DEP40MA DEP40LA
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
69
52
38
27
19
13
3
49
49
38
27
19
13
2
29
29
29
27
19
13
4
110
80
59
44
32
24
3
108
80
59
44
32
24
2
68
68
59
44
32
24
4
170
126
95
74
57
45
3
170
126
95
74
57
45
2
143
126
95
74
57
45
5
0

EMBEDMENT DEPTH DIA. 15 2.5 DEPTH DIA. 16 2.5 DEPTH DIA. 17 3.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP50HA DEP50MA DEP50LA
The pole loading charts included in this section were created to help you identify the standard pole that most closely meets
your needs. The charts include the design wind speed, sway, total EPA that the pole can support and pole embedment
requirements. Once the correct structure is identified, use the part number at the top of each section to order your pole.
Height
Above
Grade
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
DI R E C T E MB E D P OL E S
222
2011 ROHN PRODUCTS LLC
L OA DI NG C HA R T S
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
28
28
19
9
2
-
3
17
17
17
9
2
-
2
6
6
6
6
2
-
4
65
50
32
19
9
2
3
44
44
32
19
9
2
2
23
23
23
19
9
2
4
117
82
58
41
28
18
3
93
82
58
41
28
18
2
56
56
56
41
28
18
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
21
21
14
4
-
-
3
11
11
11
4
-
-
2
2
2
2
2
2
-
4
51
43
25
12
3
-
3
33
33
25
12
3
-
2
16
16
16
12
3
-
4
106
73
50
33
21
13
3
77
73
50
33
21
13
2
44
44
44
33
21
13
8
0

9
0

EMBEDMENT DEPTH DIA. 16 3.0 DEPTH DIA. 18 3.0 DEPTH DIA. 20 3.5
EMBEDMENT DEPTH DIA. 18 3.0 DEPTH DIA. 20 3.0 DEPTH DIA. 22 3.5
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
42
42
28
17
9
3
3
28
28
28
17
9
3
2
13
13
13
13
9
3
4
89
63
43
29
19
10
3
63
63
43
29
19
10
2
36
36
36
29
19
10
4
137
98
72
53
39
28
3
129
98
73
53
39
28
2
81
81
73
53
39
28
7
0

EMBEDMENT DEPTH DIA. 16 3.0 DEPTH DIA. 18 3.0 DEPTH DIA. 20 3.5
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP70HA DEP70MA DEP70LA
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP80HA DEP80MA DEP80LA
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP90HA DEP90MA DEP90LA
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
52
46
32
21
14
8
3
35
35
32
21
14
8
2
19
19
19
19
14
8
4
99
71
50
36
25
17
3
80
71
50
36
25
17
2
48
48
48
36
25
17
4
150
109
81
61
46
35
3
150
109
81
61
46
35
2
104
104
81
61
46
35
6
0

EMBEDMENT DEPTH DIA. 15 2.5 DEPTH DIA. 17 3.0 DEPTH DIA. 19 3.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP60HA DEP60MA DEP60LA
( - ) Indicates that pole is not recommended for the tabulated wind speed
223
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
DI R E C T E MB E D P OL E S
L OA DI NG C HA R T S
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
19
19
14
2
-
-
3
8
8
8
2
-
-
2
-
-
-
-
-
-
4
39
39
24
11
-
-
3
24
24
24
11
-
-
2
6
6
6
6
-
-
4
83
76
51
32
21
10
3
57
57
51
32
21
10
2
30
30
30
30
21
10
1
3
0

EMBEDMENT DEPTH DIA. 22 4.0 DEPTH DIA. 23 4.0 DEPTH DIA. 24 4.5
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
18
18
5
-
-
-
3
10
10
5
-
-
-
2
-
-
-
-
-
-
4
39
36
15
-
-
-
3
24
24
15
-
-
-
2
6
6
6
-
-
-
4
90
80
55
36
23
14
3
62
62
55
36
23
14
2
35
35
35
35
23
14
1
2
0

EMBEDMENT DEPTH DIA. 19 3.5 DEPTH DIA. 22 4.0 DEPTH DIA. 23 4.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP120HA DEP120MA DEP120LA
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP130HA DEP130MA DEP130LA
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
23
23
13
-
-
-
3
13
13
13
-
-
-
2
-
-
-
-
-
-
4
51
47
25
9
-
-
3
32
32
25
9
-
-
2
14
14
14
9
-
-
4
103
77
50
31
17
8
3
70
70
50
31
17
8
2
41
41
41
31
17
8
1
1
0

EMBEDMENT DEPTH DIA. 19 3.5 DEPTH DIA. 21 4.0 DEPTH DIA. 22 4.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP110HA DEP110MA DEP110LA
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
16
16
9
-
-
-
3
7
7
7
-
-
-
2
-
-
-
-
-
-
4
42
36
18
6
-
-
3
26
26
18
6
-
-
2
11
11
11
6
-
-
4
91
65
43
26
14
7
3
63
63
43
26
14
7
2
36
36
36
26
14
7
1
0
0

EMBEDMENT DEPTH DIA. 18 3.0 DEPTH DIA. 20 3.5 DEPTH DIA. 22 3.5
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP100HA DEP100MA DEP100LA
( - ) Indicates that pole is not recommended for the tabulated wind speed
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
DI R E C T E MB E D P OL E S
224
2011 ROHN PRODUCTS LLC
L OA DI NG C HA R T S
1. Pole designs conform to ANSI/TIA/EIA-222-F with 1/2 radial ice and to ANSI/TIA-222-G (Class I, Exposure B, Topographic
Catagory I ). Design criteria must be verified prior to installation based on site-specific requirements.
2. Embedment depths are based on Normal soil (TIA Rev. F) and clay Presumptive soil (TIA Rev. G) with aggregate backfill.
Actual site soil design parameters must be verified prior to installation.
3. For corrosive groundwater and/or soil conditions, ROHN recommends additional corrosion control protection such as concrete
backfill, additional protective coating over galvanizing or the installation of sacrificial anodes.
4. Embedment depths may require adjustment based on local soil conditions.
( - ) Indicates that pole is not recommended for the tabulated wind speed
LIGHT MEDIUM HEAVY
SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
17
17
17
-
-
-
3
5
5
5
-
-
-
2
-
-
-
-
-
-
4
47
47
30
10
-
-
3
26
26
26
10
-
-
2
6
6
6
6
-
-
4
89
89
65
39
22
6
3
63
63
63
39
22
6
2
31
31
31
31
22
6
1
5
0

LIGHT MEDIUM HEAVY


SWAY LIMIT SWAY LIMIT SWAY LIMIT
WIND SPEED (MPH)
FASTEST
MILE
3-SECOND
GUST
70
80
90
100
110
120
85
100
110
120
130
140
4
16
16
8
-
-
-
3
5
5
5
-
-
-
2
-
-
-
-
-
-
4
42
42
36
16
-
-
3
26
26
26
16
-
-
2
6
6
6
6
-
-
4
86
86
66
45
28
13
3
62
62
62
45
28
13
2
31
31
31
31
28
13
1
4
0

EMBEDMENT DEPTH DIA. 24 4.0 DEPTH DIA. 25 4.5 DEPTH DIA. 26 4.5
EMBEDMENT DEPTH DIA. 24 4.0 DEPTH DIA. 26 4.5 DEPTH DIA. 27 5.0
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP140HA DEP140MA DEP140LA
EPA (FT )
2
EPA (FT )
2
EPA (FT )
2
DEP150HA DEP150MA DEP150LA
225
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
DI R E C T E MB E D P OL E S
Pole Height
30 - 50
60 - 100
110 - 150
Part Number
TT050TSP
TT100TSP
TT150TSP
15
Grounding Lug
Ground Wire
Ground Rod
Ground Rod Clamp
Grade
PA R T S & ACC E S S OR I E S
STEP BOLTS
STEP BOLTS START AT 20 ABOVE
GRADE (NOMINAL). WHEN
ORDERING STEP BOLTS, PLEASE
SPECIFY POLE HEIGHT.
EX. SBDEP120 for a 120 POLE
JOURNEYMAN
CLIMBING HARNESS
TTFBH-4D
PROFESSIONAL
CLIMBING HARNESS
TTFBH-C/P
SAFETY CABLE SLIDER
WITH CARABINEER
TT-WG-500-W/SMC
SAFETY CABLE SYSTEM
LIGHTNING ROD
LRCL
5 COPPER CLAD
BOLTS TO CAP PLATE, PROVIDED
WITH POLE.
5.00
7.00
Reference
Elevation
Internal Hook
For Ports C-D
A through D PORTS
Larger ports are available, upon request.
P OR T DI ME NS I ONS
Cap Plate
GROUNDING KIT
BGK5GGX
KIT INCLUDES (1) GROUND LEAD, GROUND ROD AND CONNECTIONS.
ORDER (3) KITS FOR REV G GROUNDING.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
DI R E C T E MB E D P OL E S
A NT E NNA I NDE X
226
2011 ROHN PRODUCTS LLC
FLAT PANEL ANTENNA
DIMENSION SWAY LIMIT
2
5
11
4
2
2
EPA - FT
1 FT. SQUARE W/ MOUNT
2 FT. SQUARE W/ MOUNT
3 FT. SQUARE W/ MOUNT
DISH ANTENNA
DIAMETER
EPA - FT
SWAY LIMIT
3
7
11
5
11
19
6
13
22
8
18
34
4
3
2
4
3
2
W/ RADOME W/O RADOME
(1) 2 FT.
(1) 3FT.
(1) 4FT.
(2) 2 FT. B-TO-B
(2) 3 FT. B-TO-B
(2) 4 FT. B-TO-B
1. The above antenna data is intended to assist in the selection of the appropriate ROHN pole. Once the total EPA and sway limit
is determined for the antennas, the standard ROHN pole can be selected from the tabulated values. (See example below)
2. Tabulated pole EPA capacities represent the maximum EPA capacity of a pole. The capacity is based on the assumption that 80%
of the total EPA is located at the top of the pole and the remaining 20% is located 20 ft. below the top. When all loading is located
at the top of the pole, the tabulated EPA capacity must be reduced by 20%.
3. Sway limits are determined under a 50 MPH fastest-mile (Rev. F) or 60 MPH 3-second gust (Rev. G) wind speed.
4. The antenna effective projected areas (EPA) and sway limits provided in the antenna index are guidelines for typical antenna
systems. Other values may apply for specific antenna models or for site-specific systems.
2 2
1. Using the antenna index, determine the types of antennas to be installed on the pole.
2. Add together the EPA value of all the antennas to be supported.
3. Determine the most restrictive sway limit considering all the antennas to be supported. For example, for one
3 dish with a 3 sway limit and one 1 flat panel with a 4 sway limit, the sway limit for the pole would be 3 and
the required pole EPA capacity would be 13+2=15 ft .
4. If all antennas are to be supported at the top of the pole, only 80% of the tabulated EPA capacity shown may be
considered when selecting a pole. Alternately, the antenna EPA to be supported may be increased by 25%. For example,
the required pole capacity would be 15x1.25=19 ft .
5. Using the pole sway limit and the required EPA capacities, the appropriate pole may be determined from the tabulated
values. For example, for a 120 ft. pole and a 100 mph 3-sec gust wind speed, a medium pole [P/N: DEP120MA] would be
required for an EPA capacity greater than 19 ft for a 3 sway limit.



2
2
2
Determine EPA & Sway Limit for Dishes or Flat Panel Antennas
227
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
UT I L I T Y P OL E S
P R E - E NGI NE E R E D UT I L I T Y P OL E S
GENERAL USE
ROHN Pre-Engineered steel utility poles ofer a
light duty solution to satisfy utilities desiring an
alternative to wood poles. ROHNs line of
Pre-Engineered poles are lighter than typical
wooden and concrete poles and provide easy
installation and low maintenance. ROHN ofers
Pre-Engineered poles for either direct embed or
fange installations. The poles come standard with
a hot-dip galvanized coating, but can also be
painted or fabricated with weathering steel.
FEATURES
Fast, easy installation
Each pole ships with the following:
Standard ground sleeve (at grade)
Standard sub-grade corrosion coating
to 6 above grade
Cap plate
(2) 4 Nema Ground Lugs
Bearing Plate with drain hole
Jacking Lugs (at slip splices)
Optional items are available and may be ordered
separately:
Step attachment clips
Climbing pegs / step bolts
Safety climb device
Port holes
Flanged base
Painted fnish
Custom designs are available for any height
or application.
PRE-ENGINEERED
UTILITY POLES
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
UT I L I T Y P OL E S
228
2011 ROHN PRODUCTS LLC
B UY E R S GUI DE
H1 0 R P 0 5 0 W
Pole Loading
ROHN
Products
Overall
Pole Length (ft.)
Pole Finish, select either:
- Weathering
- Galvanized
The part number shown in the chart includes the pole loading and the overall length of the structure.
The coating sufx (W or G) is added by the customer at the time of the order, along with any optional
items (fanged base, step clips and safety device, ports, special grounding lugs, special ground sleeves and paint).
The example below provides a guide, for ordering convenience.
Diameters are out-to-out width between fats. Slope is change in diameter per foot of length.
Overturning moment capacity is at grade.
In the example shown, the customer is purchasing an H10RP, with an overall length of 50.
The pole is to be constructed of Weathering Steel, with a Direct Embed Base.
NOTE: Values in ( ) indicate horizontal factored loads applied 2 from the tip.
Embedment depths illustrated may require adjustment based on local soil conditions.
Pole Part Number Finish
H1 0 R P ( 18,400# / 11,500#)
Factored load for steel poles Equivalent factored load
for wood poles
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
SLOPE NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LBS)
(FT-KIP)
H1 0 R P (18,400# / 11,500#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
21.2
22.4
23.5
25.1
26.3
27.6
28.8
30.1
31.3
32.6
33.8
34.4
35.7
36.9
38.2
39.4
40.7
PART
NUMBER
H10RP040
H10RP045
H10RP050
H10RP055
H10RP060
H10RP065
H10RP070
H10RP075
H10RP080
H10RP085
H10RP090
H10RP095
H10RP100
H10RP105
H10RP110
H10RP115
H10RP120
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
0.230
0.231
0.230
0.238
0.238
0.240
0.240
0.241
0.241
0.242
0.242
0.236
0.237
0.237
0.238
0.238
0.239
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1945
2253
2581
3074
3440
3896
4304
4765
5210
5666
6148
6779
7282
7918
8459
9153
9731
368
420
472
523
576
627
680
730
785
834
890
937
995
1041
1100
1141
1206
O
T
M

@

5


=

1
8
3

f
t
-
k
i
p
s
(IN/FT)
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
TIP
AGL
(FT)
Overturning moment capacity at 5 below tip.
7.5 Tip
13.1 - 27.5
Base Diameter
Embedment
(L x .10) + 2
229
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P R ODUC T DATA
P
UT I L I T Y P OL E S
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
SLOPE NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
C 1 R P (4,500# / 2,812#)
TIP
AGL
(FT)
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
13.1
13.1
13.1
14.8
14.8
17.2
17.2
19.5
19.5
21.3
21.3
23.7
23.7
25.7
25.7
27.5
27.5
PART
NUMBER
C1RP040
C1RP045
C1RP050
C1RP055
C1RP060
C1RP065
C1RP070
C1RP075
C1RP080
C1RP085
C1RP090
C1RP095
C1RP100
C1RP105
C1RP110
C1RP115
C1RP120
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
0.140
0.124
0.112
0.133
0.122
0.149
0.139
0.160
0.150
0.162
0.153
0.171
0.162
0.173
0.165
0.174
0.167
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
981
1092
1201
1442
1553
1876
1999
2337
2477
2840
2937
3403
3560
4033
4197
4643
4820
91
103
117
128
143
153
169
179
196
204
223
229
250
267
277
280
305
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
SLOPE NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
C 2 R P (3,700# / 2,313#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
13.1
14.5
14.5
15.9
15.9
17.3
17.3
18.7
18.7
20.1
20.1
22.0
22.0
23.7
23.7
25.5
25.5
PART
NUMBER
C2RP040
C2RP045
C2RP050
C2RP055
C2RP060
C2RP065
C2RP070
C2RP075
C2RP080
C2RP085
C2RP090
C2RP095
C2RP100
C2RP105
C2RP110
C2RP115
C2RP120
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
0.140
0.156
0.140
0.153
0.140
0.151
0.140
0.149
0.140
0.148
0.140
0.153
0.145
0.154
0.147
0.157
0.150
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
981
1161
1277
1505
1629
1882
2007
2274
2406
2674
2818
3222
3368
3774
3928
4383
4547
75
84
96
105
116
137
147
157
168
178
189
199
209
215
220
230
241
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
SLOPE NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
C 3 R P (3,000# / 1,875#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
13.1
14.5
14.5
15.9
15.9
17.3
17.3
18.7
18.7
20.1
20.1
21.5
21.5
22.9
22.9
24.3
24.3
PART
NUMBER
C3RP040
C3RP045
C3RP050
C3RP055
C3RP060
C3RP065
C3RP070
C3RP075
C3RP080
C3RP085
C3RP090
C3RP095
C3RP100
C3RP105
C3RP110
C3RP115
C3RP120
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
0.140
0.156
0.140
0.153
0.140
0.151
0.140
0.149
0.140
0.148
0.140
0.147
0.140
0.147
0.140
0.146
0.140
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
981
1161
1277
1505
1626
1882
2007
2274
2406
2677
2818
3169
3312
3678
3828
4224
4384
61
68
78
85
96
102
113
119
131
136
144
153
161
170
178
187
195
O
T
M

@

5


=

5
1

f
t
-
k
i
p
s
O
T
M

@

5


=

5
3

f
t
-
k
i
p
s
O
T
M

@

5


=

5
3

f
t
-
k
i
p
s
(IN/FT)
(IN/FT)
(IN/FT)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
TIP
AGL
(FT)
TIP
AGL
(FT)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
UT I L I T Y P OL E S
230
2011 ROHN PRODUCTS LLC
P R ODUC T DATA
7.5 - 8 Tip
13.1 - 33
Base Diameter
Embedment
(L x .10) + 2
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
SLOPE
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H1 R P (5,400# / 3,375#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
13.1
14.2
14.2
16.0
16.0
18.5
18.5
21.0
21.0
23.0
23.0
26.0
26.0
28.0
28.0
29.5
29.5
PART
NUMBER
H1RP040
H1RP045
H1RP050
H1RP055
H1RP060
H1RP065
H1RP070
H1RP075
H1RP080
H1RP085
H1RP090
H1RP095
H1RP100
H1RP105
H1RP110
H1RP115
H1RP120
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
0.140
0.149
0.134
0.155
0.142
0.169
0.157
0.180
0.169
0.182
0.172
0.195
0.185
0.195
0.186
0.191
0.183
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
981
1161
1261
1516
1636
1966
2102
2465
2611
2952
3092
3705
3872
4309
4488
4950
5133
109
138
140
153
171
184
202
214
234
245
246
278
298
305
330
336
363
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H2 R P (6,400# / 4,000#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
13.6
16.0
16.0
17.5
17.5
19.4
19.4
22.0
22.0
24.5
24.5
27.3
27.3
29.4
29.4
31.4
31.4
PART
NUMBER
H2RP040
H2RP045
H2RP050
H2RP055
H2RP060
H2RP065
H2RP070
H2RP075
H2RP080
H2RP085
H2RP090
H2RP095
H2RP100
H2RP105
H2RP110
H2RP115
H2RP120
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
7.8
0.145
0.182
0.164
0.176
0.162
0.178
0.166
0.189
0.178
0.196
0.186
0.205
0.195
0.206
0.196
0.205
0.197
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1016
1251
1375
1638
1765
2056
2194
2592
2744
3138
3304
3880
4055
4510
4698
5236
5433
129
146
165
182
202
218
239
254
277
290
314
326
352
362
390
398
428
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H3 R P (7,500# / 4,688#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
14.8
17.0
17.0
18.8
18.8
21.0
21.0
23.2
23.2
26.0
26.0
28.6
28.6
31.2
31.2
33.0
33.0
PART
NUMBER
H3RP040
H3RP045
H3RP050
H3RP055
H3RP060
H3RP065
H3RP070
H3RP075
H3RP080
H3RP085
H3RP090
H3RP095
H3RP100
H3RP105
H3RP110
H3RP115
H3RP120
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
0.170
0.200
0.180
0.196
0.180
0.200
0.186
0.203
0.190
0.212
0.200
0.217
0.206
0.221
0.211
0.217
0.208
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1077
1309
1440
1728
1865
2184
2335
2708
2870
3302
3475
4044
4226
4775
4973
5480
5684
150
171
193
213
235
255
278
298
321
340
365
382
407
424
451
466
494
O
T
M

@

5


=

5
2

f
t
-
k
i
p
s
O
T
M

@

5


=

5
7

f
t
-
k
i
p
s
O
T
M

@

5


=

6
2

f
t
-
k
i
p
s
(IN/FT)
SLOPE
(IN/FT)
SLOPE
(IN/FT)
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
TIP
AGL
(FT)
TIP
AGL
(FT)
TIP
AGL
(FT)
8.5 - 9 Tip
16.5 - 38.5
Base Diameter
Embedment
(L x .10) + 2
231
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P R ODUC T DATA
P
UT I L I T Y P OL E S
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H4 R P (8,700# / 5,438#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
16.5
18.2
18.2
20.2
20.2
22.2
22.2
24.3
24.3
27.2
27.2
30.0
30.0
32.3
32.3
34.9
34.9
PART
NUMBER
H4RP040
H4RP045
H4RP050
H4RP055
H4RP060
H4RP065
H4RP070
H4RP075
H4RP080
H4RP085
H4RP090
H4RP095
H4RP100
H4RP105
H4RP110
H4RP115
H4RP120
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
0.200
0.216
0.194
0.213
0.195
0.211
0.196
0.211
0.198
0.220
0.208
0.226
0.215
0.227
0.216
0.230
0.220
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1116
1336
1476
1786
1935
2253
2410
2788
2956
3403
3589
4171
4365
4929
5137
5766
5985
174
199
223
247
273
296
322
345
372
394
421
443
471
492
522
541
572
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H5 R P (10,000# / 6,250#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
17.5
20.0
20.0
22.0
22.0
24.3
24.3
26.5
26.5
29.0
29.0
31.7
31.7
34.3
34.3
37.0
37.0
PART
NUMBER
H5RP040
H5RP045
H5RP050
H5RP055
H5RP060
H5RP065
H5RP070
H5RP075
H5RP080
H5RP085
H5RP090
H5RP095
H5RP100
H5RP105
H5RP110
H5RP115
H5RP120
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
0.213
0.244
0.220
0.236
0.217
0.235
0.219
0.233
0.219
0.235
0.222
0.239
0.227
0.241
0.230
0.243
0.233
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1181
1447
1601
1929
2090
2459
2631
3016
3198
3625
3820
4436
4640
5231
5449
6137
6365
200
228
257
284
314
341
371
397
429
453
487
509
545
566
603
622
662
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H6 R P (11,400# / 7,125#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
18.2
21.0
21.0
23.2
23.2
25.7
25.7
28.3
28.3
30.8
30.8
33.4
33.4
37.0
37.0
38.5
38.5
PART
NUMBER
H6RP040
H6RP045
H6RP050
H6RP055
H6RP060
H6RP065
H6RP070
H6RP075
H6RP080
H6RP085
H6RP090
H6RP095
H6RP100
H6RP105
H6RP110
H6RP115
H6RP120
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
0.230
0.267
0.240
0.258
0.237
0.257
0.239
0.257
0.241
0.256
0.242
0.257
0.244
0.267
0.255
0.257
0.246
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1211
1495
1655
2003
2173
2565
2741
3191
3381
3816
4021
4622
4835
5592
5820
7182
7529
228
260
292
324
357
388
421
452
486
517
551
581
616
645
681
709
746
O
T
M

@

5


=

7
1

f
t
-
k
i
p
s
O
T
M

@

5


=

8
0

f
t
-
k
i
p
s
O
T
M

@

5


=

8
2

f
t
-
k
i
p
s
SLOPE
(IN/FT)
SLOPE
(IN/FT)
SLOPE
(IN/FT)
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
TIP
AGL
(FT)
TIP
AGL
(FT)
TIP
AGL
(FT)
10.0 Tip
20.0 - 38.7
Base Diameter
Embedment
(L x .10) + 2
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
UT I L I T Y P OL E S
232
2011 ROHN PRODUCTS LLC
P R ODUC T DATA
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H7 R P (13,120# / 8,200#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
20.0
21.3
22.5
22.8
24.0
25.2
26.4
27.6
28.8
30.2
31.2
31.9
33.1
34.3
35.5
36.7
37.9
PART
NUMBER
H7RP040
H7RP045
H7RP050
H7RP055
H7RP060
H7RP065
H7RP070
H7RP075
H7RP080
H7RP085
H7RP090
H7RP095
H7RP100
H7RP105
H7RP110
H7RP115
H7RP120
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
0.250
0.250
0.250
0.233
0.233
0.234
0.234
0.235
0.235
0.238
0.236
0.231
0.231
0.231
0.232
0.232
0.233
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1336
1558
1791
2565
2867
3180
3509
3816
4219
4643
5008
5899
6365
6853
7356
7853
8369
263
299
337
373
411
446
485
521
559
595
634
668
710
742
784
816
859
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H8 R P (15,040# / 9,400#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
19.2
20.4
21.5
22.2
23.3
24.4
25.6
26.8
27.9
29.1
30.2
30.9
32.0
33.2
34.3
35.4
36.6
PART
NUMBER
H8RP040
H8RP045
H8RP050
H8RP055
H8RP060
H8RP065
H8RP070
H8RP075
H8RP080
H8RP085
H8RP090
H8RP095
H8RP100
H8RP105
H8RP110
H8RP115
H8RP120
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
0.230
0.231
0.230
0.222
0.222
0.222
0.223
0.224
0.224
0.225
0.224
0.220
0.220
0.221
0.221
0.221
0.222
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1712
1993
2295
2645
2968
3366
3726
4161
4553
4961
5385
5925
6331
6917
7404
8040
8560
301
343
385
428
471
512
556
597
642
682
727
766
814
851
900
935
986
OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H9 R P (16,800# / 10,500#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
20.0
21.2
22.5
23.1
24.3
25.6
26.8
28.1
29.3
30.6
31.8
32.4
33.7
34.9
36.2
37.4
38.7
PART
NUMBER
H9RP040
H9RP045
H9RP050
H9RP055
H9RP060
H9RP065
H9RP070
H9RP075
H9RP080
H9RP085
H9RP090
H9RP095
H9RP100
H9RP105
H9RP110
H9RP115
H9RP120
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
0.250
0.249
0.250
0.238
0.238
0.240
0.240
0.241
0.241
0.242
0.242
0.236
0.237
0.237
0.238
0.238
0.239
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1754
2050
2364
2740
3085
3477
3853
4314
4728
5175
5607
6153
6625
7240
7754
8401
8946
315
383
420
478
526
572
621
667
716
761
812
856
908
950
1004
1045
1100
O
T
M

@

5


=

8
5

f
t
-
k
i
p
s
O
T
M

@

5


=

1
3
0

f
t
-
k
i
p
s
O
T
M

@

5


=

1
3
3

f
t
-
k
i
p
s
SLOPE
(IN/FT)
SLOPE
(IN/FT)
SLOPE
(IN/FT)
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
TIP
AGL
(FT)
TIP
AGL
(FT)
TIP
AGL
(FT)
12.0 Tip
21.2 - 40.7
Base Diameter
Embedment
(L x .10) + 2
233
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P R ODUC T DATA
P
UT I L I T Y P OL E S
Design Notes:
1. Pole designs are in accordance with ASCE 48, Design of Steel Transmission Pole Structures.
2. Pole sections are ASTM grade 65 material with a charpy impact value of 15 ft-lbs at -20 F.
3. Multiple section poles include slip splice joints with a minimum slip length equal to 1.5 times the inside
diameter across flats of the outer section at the splice.
4. Galvanized poles are hot-dip galvanized in accordance with ASTM A123.
5. Tabulated weights assume galvanized poles.

OVERTURNING
TIP BASE
MOMENT
DIAMETER DIAMETER
NO. WEIGHT
CAPACITY
(IN) (IN)
SECTIONS (LB)
(FT-KIP)
H1 0 R P (18,400# / 11,500#)
TOTAL
LENGTH
(FT) L
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
21.2
22.4
23.5
25.1
26.3
27.6
28.8
30.1
31.3
32.6
33.8
34.4
35.7
36.9
38.2
39.4
40.7
PART
NUMBER
H10RP040
H10RP045
H10RP050
H10RP055
H10RP060
H10RP065
H10RP070
H10RP075
H10RP080
H10RP085
H10RP090
H10RP095
H10RP100
H10RP105
H10RP110
H10RP115
H10RP120
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
0.230
0.231
0.230
0.238
0.238
0.240
0.240
0.241
0.241
0.242
0.242
0.236
0.237
0.237
0.238
0.238
0.239
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
1945
2253
2581
3074
3440
3896
4304
4765
5210
5666
6148
6779
7282
7918
8459
9153
9731
368
420
472
523
576
627
680
730
785
834
890
937
995
1041
1100
1141
1206
O
T
M

@

5


=

1
8
3

f
t
-
k
i
p
s
o
SLOPE
(IN/FT)
34.0
38.5
43.0
47.5
52.0
56.5
61.0
65.5
70.0
74.5
79.0
83.5
88.0
92.5
97.0
101.5
106.0
TIP
AGL
(FT)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
UT I L I T Y P OL E S
234
2011 ROHN PRODUCTS LLC
Pole Height
(AGL)
30 - 50
60 - 100
110 - 150
Part Number
TT050TSP
TT100TSP
TT150TSP
15
PA R T S & ACC E S S OR I E S
STEP BOLTS
STEP BOLTS AND STEP BOLT CLIPS
ARE OPTIONAL AND MUST BE
SPECIFIED AT TIME OF ORDER.
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SLIDER
WITH CARABINEER
TT-WG-500-W/SMC
SAFETY CABLE SYSTEM
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
235
2011 ROHN PRODUCTS LLC

NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
UT I L I T Y S T R UC T UR E S
UT I L I T Y S T R UC T UR E S
236
2011 ROHN PRODUCTS LLC
GENERAL
ROHN has been a trusted name in quality engineered
structures since 1948. Our extensive engineering capabilities
include in-house structural and foundation design. We are
able to design to both domestic and international standards.
ROHN is one of the few tower designers and manufacturers
able to provide drawings sealed by a Professional Engineer,
to customers in 49 states as well as Washington DC and
Puerto Rico. ROHN is able to fabricate even the most difcult
projects with accuracy and reliability. ROHN can optimize
pole designs based on individual customer requirements,
manufacturing efciencies and material availability. Our
commitment to the Utility industry is to provide world class
quality products with the shortest lead time.
CERTIFICATIONS
CWB Certifed Welding Fabricator
AWS Certifed Welding Fabricator, Inspectors and Educators
Dual AISC Certifed Steel Fabricator (Bridges & Highways)
City of Los Angeles Certifed Fabricator
Clark County Certifed Fabricator
Multiple Vendor Certifcation
CAPABILITIES
Heavy Duty Transmission & Distribution Poles
Direct Embed & Base Plated Poles
Lattice Structures
Switches & Substation Steel
Galvanized, Weathering Steel & Painted Finishes
Tapered Slip Fit or Connection Flanged Poles
237
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
UT I L I T Y S T R UC T UR E S
TRANSMISSION
ROHN fabricates transmission structures for projects ranging
from light-duty in-line poles up to the largest diameter dead
end structures. The structures are cut, formed, fabricated and
galvanized on site at ROHN. ROHN can provide engineering,
detailing and our AISC Certifed fabrication facility can support
large or small transmission projects across the globe.
DISTRIBUTION
ROHN provides structures to support electric power distribution
in its many forms. ROHN ofers both pre-engineered steel
structures (wood pole equivalents) and larger distribution
structures that can either be fanged at the base or direct
embedded. ROHN also ofers a wide selection of corrosion
resistant coatings to guarantee the product life.
SUBSTATION STEEL
ROHN fabricates all forms of substation steel to allow the entire
transmission and distribution build to be supplied by ROHN.
We have hollow steel structures in stock to turn substation work
around on time to keep pace with project schedules. ROHN
can supply all cross arms, uprights, H-frames and any steel
frame or support to complete the substation. Each substation
item is hot-dip galvanized after fabrication for corrosion
resistance.
SWITCHES
ROHN fabricates switch steel structures including all static
masts, buss supports, arrestor structures, and all other steel
components that make up the switch. The steel is fabricated
by AWS and CWB welders in our AISC certifed fabrication
plant. From start to fnish, we have your project covered.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
T R A NS P OR TAT I ON S T R UC T UR E S
T R A NS P OR TAT I ON S T R UC T UR E S
238
2011 ROHN PRODUCTS LLC
GENERAL
ROHN has been a trusted name in quality engineered
structures since 1948. Our engineers study every aspect of
a prospective job before designing a structure to ft your
needs. We are able to design to both domestic and
international standards. ROHN provides professional
engineering certifcation for our designs. Our engineers
are certifed in 49 states as well as Washington DC and
Puerto Rico. ROHN is able to fabricate the most difcult
projects with accuracy and reliability. ROHN can optimize
pole designs based on individual customer requirements,
manufacturing efciencies and material availability. Our
commitment to the Transportation Industry is to provide world
class quality products with the shortest lead time.
CERTIFICATIONS
AISC Certifed Steel Fabricator (Buildings & Simple Steel Bridges)
AWS Certifed Welders, Inspectors and Educators
CWB Certifed Welding Fabricator
City of Los Angeles Certifed Fabricator
Clark County Certifed Fabricator
Multiple Vendor Certifcations
Manufactured to AASHTO Standards
CAPABILITIES
Mast Arms
Monotube Assemblies
Steel Strain Poles
High Past Poles
Galvanized or Painted Finishes
Weathering Steel
Sign Structures
239
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
T R A NS P OR TAT I ON S T R UC T UR E S


MAST ARMS
ROHN is considered the quality leader to state, county and
municipal buyers of mast arm structures. ROHN mast arms
are in service at intersections as wide as 88. Our designs
conform to all AASHTO standards as well as local design codes.
ROHNs mast arms can be hot-dip galvanized and can also be
painted upon request.
HIGH MAST POLES
For years, ROHN has been a reliable manufacturer of high
mast lighting poles for state D.O.T. projects, prisons, port
authorities and other commercial projects across the country.
These organizations and many others choose ROHN because
of our proven quality in manufacturing and design, as well as
our focus on fnding the best possible value for our customers.
High mast lighting poles range in height from 60 to 150 and
are designed to accommodate a number of lowering device
manufacturers equipment. High mast poles can be galvanized
or painted based on customer requirements.
MONOTUBE ASSEMBLIES
In applications where a very long span is needed and a more
decorative appearance is needed, some State Departments
of Transportation will specify monotube assemblies for Tubular
Signal Structures and Sign Bridge Applications.
All ROHN monotube assemblies are designed to AASHTO
standards and comply with appropriate state specifcations.
These monotube assemblies can range from 20 to 200 and
are designed to accommodate a number of various highway
signs and signals. Monotube assemblies can be galvanized or
painted based on customer requirements.
SIGN STRUCTURES
ROHN Products, LLC has the experience and expertise to
address all of your metal fabrication needs. Through 60 years,
ROHN has expanded into fabricated Sign Structures and now
has the capabilities to design and build Steel Overhead Sign
Trusses, Cantilever Structures, Butterfy Structures, and DMS
Sign Structures. ROHN Products, LLC is certifed by the
American Institute of Steel Construction for both Steel Building
Structures and Simple Steel Bridges. Our welders are qualifed
in accordance with the American Welding Society and various
State DOT Requirements.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
P
WI ND T UR B I NE S T R UC T UR E S
WI ND T UR B I NE S T R UC T UR E S
240
2011 ROHN PRODUCTS LLC
GENERAL
ROHN provides an extensive analysis on Wind Turbine
structures that includes examination of extreme wind,
extreme ice, yawing, fatigue, vibration and more. The
dynamic nature of a wind turbine requires an additional
investment in the analysis of the support structure to
ensure the structures perform safely and efciently.
CERTIFICATIONS
AISC Certifed Steel Fabricator (Buildings & Simple Steel Bridges)
AWS Certifed Welders, Inspectors and Educators
CWB Certifed Welding Fabricator
City of Los Angeles Certifed Fabricator
Clark County Certifed Fabricator
Multiple Vendor Certifcations
CAPABILITIES
Pole, Self-Supporting Latticed and Guyed Mast Designs
Fatigue Analysis
Natural Frequency Analysis
Preparation of Loading Documents
Braking, Short Circuit, Shutdown Analysis
Special Design Requests Considered
241
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P
WI ND T UR B I NE S T R UC T UR E S


SELF-SUPPORTING TOWERS
ROHN Self-Supporting Towers provide an efcient design
specifc for each turbines loading criteria. The towers are
designed with tubular or solid legs and angle braces. The
tower top fange is designed with a transition plate to
receive the turbine base. ROHN lightweight towers have
been designed with hinged bases to allow the tower to be
slowly lowered for turbine maintenance and repairs.

POLES
ROHN designs both tapered slip joint poles and fanged poles
to support Wind Turbines. ROHN turbine support poles have
ranged from 30 in height to 140 in height supporting turbines
up to 50 kW.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
242
NOT E S
T
T E L E S COP I NG MA S T S
T E L E S COP I NG MA S T S
F OR U S E I N G U Y E D OR B R A C K E T E D I N S TA L L AT I ON S
ROHN Telescoping Masts are available in 20, 30, 33, 40
and 50 nominal heights. All are pre-galvanized for corrosion
protection and come assembled with hardware.
Specifications:
All installations must be guyed or bracketed. Installation
of masts should be done by experienced professionals.
Telescoping Masts are not recommended for commercial,
CB or beam antenna installations.
Part No.
H20
H30
H40
H50
9H50*
Wt.
17 lbs.
27 lbs.
36 lbs.
46 lbs.
34 lbs.
O.D. Bottom
1 1/2
1 3/4
2
2 1/4
2 1/4
O.D. Top
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
Shipping Length
123
123
123
123
99
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
244
*9H50 is UPS shippable.
Note:
Guys, guy hardware, anchors and base mount
must be ordered separately. Refer to pages
245-248 for standard kits and page 249 for
individual components.
T E L E S COP I NG MA S T S
T
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
245
T E L E S COP I NG MA S T S
H 2 0 | H 3 0 | H 4 0 | H 5 0 | 9 H 5 0
H20 H30 H50 9H50
N
E
W


P
RO
D
U
C
T
9H50
UPS Shippable!
Top rings are adjustable based on antenna
mounting.
114
231
108
223
336
102
211
435
322
96
199
415
304
527
72
152
410
233
320
H40
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T
T E L E S COP I NG MA S T S
246
2011 ROHN PRODUCTS LLC
I NS TA L L AT I ON GUI DE L I NE S
1
8
T
Y
P
90 TYP

18 TYP
120 TYP

29 TYP
23 TYP
29 TYP
23 TYP
TOP VIEW ELEVATION VIEW TOP VIEW ELEVATION VIEW
H203WAYGUY
Actual Wire Required - 200
H204WAYGUY
Actual Wire Required - 250
3 Guy Wire Setup
4 Guy Wire Setup
2
7
T
Y
P
90 TYP

27 TYP
120 TYP

31 TYP
TOP VIEW ELEVATION VIEW TOP VIEW ELEVATION VIEW
H303WAYGUY
Actual Wire Required - 350
H304WAYGUY
Actual Wire Required - 450
3 Guy Wire Setup 4 Guy Wire Setup
H
3
0

G
U
Y

K
I
T
35 TYP
41 TYP
31 TYP
35 TYP
41 TYP
H
2
0

G
U
Y

K
I
T
All Telescoping Mast kits include guys, connection hardware, anchors and ground mount.
Mast must be ordered separately.
18 18
27 27
1 618 1000 - 6 Strand/18 GA Wire
3 GAS4303 1/2 x 30 Screw Anchor
12 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
1 618 1000 - 6 Strand/18 GA Wire
4 GAS4303 1/2 x 30 Screw Anchor
16 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
1 618 1000 - 6 Strand/18 GA Wire
3 GAS4303 1/2 x 30 Screw Anchor
18 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
1 618 1000 - 6 Strand/18 GA Wire
4 GAS4303 1/2 x 30 Screw Anchor
24 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T E L E S COP I NG MA S T S
247
2011 ROHN PRODUCTS LLC
T
I NS TA L L AT I ON GUI DE L I NE S
3
6
T
Y
P
90 TYP

36 TYP
120 TYP

39 TYP
TOP VIEW ELEVATION VIEW TOP VIEW ELEVATION VIEW
3 Guy Wire Setup
4 Guy Wire Setup
H
4
0

G
U
Y

K
I
T
4
3
.5
T
Y
P
90 TYP

43.5 TYP
120 TYP

47 TYP
TOP VIEW ELEVATION VIEW TOP VIEW ELEVATION VIEW
3 Guy Wire Setup 4 Guy Wire Setup
64 TYP
43 TYP
47 TYP
54 TYP
39 TYP
43 TYP
47 TYP
54 TYP
49 TYP
53 TYP
58 TYP
47 TYP
64 TYP
49 TYP
53 TYP
58 TYP
H
5
0

G
U
Y

K
I
T
H503WAYGUY
Actual Wire Required - 850
H504WAYGUY
Actual Wire Required - 1100
H403WAYGUY
Actual Wire Required - 550
H404WAYGUY
Actual Wire Required - 750
All Telescoping Mast kits include guys, connection hardware, anchors and ground mount.
Mast must be ordered separately.
36 36
43.5 43.5
1 618 1000 - 6 Strand/18 GA Wire
3 GAS4303 1/2 x 30 Screw Anchor
24 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
1 618 1000 - 6 Strand/18 GA Wire
4 GAS4303 1/2 x 30 Screw Anchor
32 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
1 618 1000 - 6 Strand/18 GA Wire
3 GAS604 5/8 x 48 Screw Anchor
30 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
2 618 1000 - 6 Strand/18 GA Wire
4 GAS604 5/8 x 48 Screw Anchor
40 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
I NS TA L L AT I ON GUI DE L I NE S
9
H
5
0

G
U
Y

K
I
T
9H503WAYGUY
Actual Wire Required - 650
9H504WAYGUY
Actual Wire Required - 850
All Telescoping Mast kits include guys, connection hardware, anchors and ground mount.
Mast must be ordered separately.
1 618 1000 - 6 Strand/18 GA Wire
3 GAS604 5/8 x 48 Screw Anchor
30 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
1 618 1000 - 6 Strand/18 GA Wire
4 GAS604 5/8 x 48 Screw Anchor
40 61820GRPL 618/620 Gripple
1 GTMBL Ground Mount
I NS TA L L AT I ON GUI DE L I NE S
1. Installation or dismantling of telescoping masts require professional contractors experienced with guyed masts.
2. All installations must be bracketed or guyed.
3. The pictured guy layouts are for a typical installation. Individual installation requirements may vary.
4. Antenna load (top load) should not exceed an effective projected area (EPA) of 2 square feet (see your antenna specifications).

3
3
.5
T
Y
P
90 TYP

33.5 TYP
120 TYP

36 TYP
TOP VIEW ELEVATION VIEW TOP VIEW ELEVATION VIEW
3 Guy Wire Setup 4 Guy Wire Setup
50 TYP
38 TYP
41 TYP
45 TYP
36 TYP
50 TYP
38 TYP
41 TYP
45 TYP
33.5 33.5
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T
T E L E S COP I NG MA S T S
248
2011 ROHN PRODUCTS LLC
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T E L E S COP I NG MA S T S
249
2011 ROHN PRODUCTS LLC
T
PA R T S & ACC E S S OR I E S
UNIVERSAL RIDGE MOUNT
Completely assembled for
quick and easy flat or peaked roof
installation. Allows tall masts to
be swung up along the ridge of
a roof.
Part No. Description
UM20 Holds masts to 1 1/2 O.D.
UM30 Holds masts to 1 3/4 O.D.
UM40 Holds masts to 2 O.D.
UM50 Holds masts to 2 1/4 O.D.
GROUND MOUNT
Sturdy, galvanized, drive-in type
mount for all ROHN telescoping
masts, 1 1/4 tubing and 1 1/2
tubing.
Part No. Description
GTMBL Ground Mount
UNIVERSAL ROOF MOUNT
Features galvanized finish
and heavy duty steel throughout.
Completely assembled. Holds all
ROHN telescoping masts, 1 1/4
tubing and 1 1/2 tubing.
Part No. Description
ETMB Universal Mount
GALVANIZED GUYS
Non-tangling interconnected
coils. Packaged 1000 per box.
Part No. Description
618 6 strand, 18 GA

SCREW ANCHORS
Hot-dip galvanized screw anchor.
Part No. Description
GAS4303 1/2dia. x 30 long with 4auger
GAS604 5/8dia. x 48 long with 6auger

GUY CONNECTIONS
Use for easy installation of 6 strand,
18 GA guys.
Part No. Description
61820GRPL Gripple Grip
Not to be used to suspend or lift personnel.
Refer to page 251 for roof mounts. Refer to page 275 for wall mounts.
Roof mounting hardware not included. Roof mounting hardware not included.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
250
NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S
252
2011 ROHN PRODUCTS LLC
RM
E F F E C T I V E WI ND V E L OC I T Y F OR MUL A S HE E T
V = (C1) (C2) (V)
e
V = Efective Wind Velocity at centerline of antenna for calculating required ballast.
e
C1 = Importance factor coefcient from Table 1.
C2 = Combined exposure and gust efect factor coefcient from Table 2.
V = Design ground wind speed for location, per ANSI/TIA-222-G.
Table 1: Values of C1
I Low hazard to human life and/or damage to property, optional services provided. 1.29 0.93
II Signifcant hazard to human life and/or damage to property, services available by other means. 1.38 1.00
III Substantial hazard to human life and/or damage to property, essential services provided. 1.48 1.07
Class Description for installing considering height, use or location 60 ft. > 60 ft.
Roof Height
Urban and suburban areas, wooded areas, or
other terrain with numerous closely spaced
obstructions having the size of single-family
dwellings or larger.
Open terrain with scattered obstructions having
heights generally less than 30 [9.1m], including
fat, open country and grasslands.
Flat, unobstructed shorelines exposed to wind
fowing over open water, smooth mud fats, salt
fats, and other similar terrain.
Exposure Description of Surrounding Terrain
B
C
D
Example: 30 antenna elevation, 90 mph design ground
wind speed, Class I, Exposure B
V = (1.29) (0.82) (90) = 95 mph
The minimum Efective Wind Velocity for
determining ballast requirements for this
example would be 95 mph.
e
0-15 0.82 0.90 0.99
20 0.82 0.92 1.01
25 0.82 0.95 1.04
30 0.82 0.96 1.05
40 0.85 0.99 1.08
50 0.88 1.02 1.10
60 0.90 1.04 1.12
70 0.92 1.05 1.13
80 0.94 1.07 1.14
90 0.95 1.09 1.16
100 0.97 1.10 1.17
120 0.99 1.12 1.19
140 1.02 1.14 1.20
160 1.04 1.15 1.21
180 1.05 1.17 1.23
200 1.07 1.18 1.24
250 1.10 1.21 1.26
300 1.13 1.23 1.28
350 1.16 1.25 1.30
400 1.18 1.27 1.31
450 1.20 1.29 1.33
500 1.22 1.30 1.34
Antenna
Centerline
Elevation Above
Ground Level (ft.)
Urban or
Wooded
Areas
Open Country
& Grasslands
Open Water or
Smooth Terrain
B C D
Exposure
Table 2: Values of C2
This data sheet is provided to assist consumers in determining
the minimum Efective Wind Velocity to be used for determining
ballast requirements from a ROHN Non-Penetrating Roof Mount
Ballast Chart. Higher velocities may be required for sites located
on hills, escarpments or ridges (refer to ANSI/TIA-222-G). Potential
increases in wind velocity due to channeling, roof projections
and other obstructions must also be considered. The information
shown should not be relied upon without competent professional
examination and verifcation of its accuracy and suitability for a
specifc site or application.
ROHN recommends a minimum 75 mph Efective Wind Velocity be used for determining ballast requirements.
Refer to page 270 for ballast requirements and general notes.
<
_
253
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - FRM
RM
F R M
N ON - P E N E T R AT I N G
Mount
Part No.
FRM125
FRM150
FRM166
FRM238
FRM225
FRM238SP5
Mast
Part No.
FY202
FY203
FY204
FY205
FY205SP
FY253
Mast Description & Height
1.25 O.D. x 16 GA. x 5.0 (PG)
1.50 O.D. x 16 GA. x 2.5 (PG)
1.66 O.D. x 16 GA. x 2.5 (PG)
2.38 O.D. x 0.154 wall x 2.5 (HDG)
2.25 O.D. x 14 GA. x 5.0 (HDG)
2.38 O.D. x 0.154 wall x 5.0 (HDG)
MAST SPECIFICATIONS
F R M B AL L AS T R E QU I R E ME NT S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=2 FT h=3 FT h=4 FT h=5 FT
100
200
300
400
100
200
300
400
100
200
300
400
12
24
36
48
12
24
36
48
12
24
36
48
140
198
242
280
99
140
171
198
81
114
140
161
135
188
222
269
96
133
157
190
78
108
128
155
110
153
182
219 (197)
78
108
129
155 (139)
64
88
105
127 (114)
96
133
157 (154)
190 (154)
68
94
111
134(109)
55
77
91 (89)
110 (89)
85
119
141 (131)
170 (131)
60
84
99 (93)
120 (93)
49
68
81 (76)
98 (76)
2
4
6
h = Distance from support surface to centroid of EPA.
Vs = Effective wind velocity resulting in sliding on a flat surface with
a .50 coefficient of friction.
Vmax = Effective wind velocity based on strength or overturning.
NOTE: The velocities in ( ) apply to the FRM125 mount when the
strength of the FRM125 mast governs.
3 Square
The FRM mount is a lightweight mount and is galvanized for corrosion protection. The FRM mount is easily shipped via UPS.
Order (1) optional FRMMAT (1/8 thick) or (1) optional
FRMPAD (3/8 thick) for a protective barrier between
the mount and the roof. Order (1) optional SCK150
safety cable kit (3/8 x 150).
1.25 to 2.38 Mast
Tube Diameters
2.5 and 5 Overall
Mast Heights
(See Mast Descriptions)
PG = Pre-galvanized mast
HDG = Hot-dip galvanized mast
16 Nominal Blocks
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - J R M
254
2011 ROHN PRODUCTS LLC
RM
J R M
N ON - P E N E T R AT I N G
5 Square
The JRM ships broken down on one skid and weighs approximately 50 lbs. when assembled. The JRM is galvanized for corrosion
protection. The JRM is used in cellular, PCS, broadband and other applications.
Order (1) optional JRMMAT (1/8 thick) or (1) optional
JRMPAD (3/8 thick) for a protective barrier between the
mount and the roof. Order (1) optional SCK150 safety
cable kit (3/8 x 150).
Refer to pages 255-256 for ballast requirements.
Mount
Part No.
JRM23805
JRM23855
JRM23810
JRM27505
JRM27555
JRM27510
JRM35010
Mast Description & Height
2.38 O.D. x 0.154 wall x 5.0 (HDG) (1 piece)
2.38 O.D. x 0.154 wall x 10.0 (HDG) (2 pieces)
2.38 O.D. x 0.154 wall x 10.0 (HDG) (1 piece)
2.88 O.D. x 0.203 wall x 5.0 (HDG) (1 piece)
2.88 O.D. x 0.203 wall x 10.0 (HDG) (2 pieces)
2.88 O.D. x 0.203 wall x 10.0 (HDG) (1 piece)
3.50 O.D. x 0.216 wall x 10.0 (HDG) (1 piece)
MAST SPECIFICATIONS
Mast
Part No.
FZ1755
FZ1753 / FZ1754
FZ1756
FZ1757
FZ1758 / FZ1759
FZ1760
FZ1761
HDG = Hot-dip galvanized mast
2.38 to 3.50 Mast Tube Diameters,
1 and 2 piece options
5 or 10 (1 & 2 piece) Overall Mast Heights
(See Mast Descriptions)
16 Nominal Blocks
255
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - JRM
RM
J R M
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=2 FT h=3 FT h=4 FT h=5 FT h=6 FT h=7 FT h=8 FT h=9 FT
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
110
131
148
164
178
191
204
215
226
237
247
99
117
133
147
159
171
182
193
203
212
221
90
107
121
134
145
156
166
176
185
193
202
84
99
112
124
135
145
154
163
171
179
187
78
92
105
116
126
135
144
152
160
168
175
70
83
94
104
113
121
129
136
143
150
156
129
153
173
191
208
224
238
252
265
277
289
115
137
155
171
186
200
213
225
237
248
258
105
125
141
156
170
183
194
205
216
226
236
98
115
131
145
157
169
180
190
200
209
218
91
108
122
135
147
158
168
178
187
196
204
82
97
110
121
132
141
151
159
167
175
183
105
125
141
156
170
183
194
205
216
226
236
94
112
126
140
152
163
174
184
193
202
211
86
102
115
128
139
149
159
168
176
185
192
80
94
107
118
128
138
147
155
163
171
178
75
88
100
111
120
129
137
145
153
160
167
67
79
89
99
107
115
123
130
137
143
149
91
108
122
135
147
158
168
178
187
196
204
82
97
110
121
132
141
151
159
167
175
183
75
88
100
111
120
129
137
145
153
160
167
69
82
93
102
111
120
127
135
141
148
154
65
76
87
96
104
112
119
126
132
138
144
58
68
77
86
93
100
106
113
118
124
129
82
97
110
121
132
141
151
159
167
175
183
73
86
98
108
118
126
135
142
150
157
163
67
79
89
99
107
115
123
130
137
143
149
62
73
83
92
100
107
114
120
126
132
138
58
68
77
86
93
100
106
113
118
124
129
52
61
69
77
83
89
95
101
106
111
115
75
88
100
111
120
129
137
145
153
160
167
67
79
89
99
107
115
123
130
137
143
149
61
72
82
90
98
105
112
119
125
131
136
56
67
76
84
91
98
104
110
115
121
126
53
62
71
78
85
91
97
103
108
113
118
47
56
63
70
76
82
87
92
97
101
105
69
82
93
102
111
120
127
135
141
148
154
62
73
83
92
100
107
114
120
126
132
138
56
67
76
84
91
98
104
110
115
121
126
52
62
70
77
84
90
96
102
107
112
117
49
58
65
72
79
85
90
95
100
105
109
44
52
59
65
70
76
80
85
89
94
98
65
76
87
96
104
112
119
126
132
138
144
58
68
77
86
93
100
106
113
118
124
129
53
62
71
78
85
91
97
103
108
113
118
49
58
65
72
79
85
90
95
100
105
109
46
54
61
68
74
79
84
89
94
98
102
41
48
55
61
66
71
75
80
84
88
91
61
72
82
90
98
105
112
119
125
131
136
54
64
73
81
88
94
100
106
112
117
122
50
59
67
74
80
86
92
97
102
107
111
46
54
62
68
74
80
85
90
94
99
103
43
51
58
64
69
75
79
84
88
92
96
38
46
52
57
62
67
71
75
79
83
86
4
5
6
7
8
10
Vmax = Effective wind velocity based
on strength or overturning.
h = Distance from support
surface to centroid of
EPA.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - J R M
256
2011 ROHN PRODUCTS LLC
RM
J R M
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=2 FT h=3 FT h=4 FT h=5 FT h=6 FT h=7 FT h=8 FT h=9 FT
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
250
350
450
550
650
750
850
950
1050
1150
1250
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
10.0
14.0
18.0
22.0
26.0
30.0
34.0
38.0
42.0
46.0
50.0
64
75
86
95
103
110
118
124
131
137
143
59
70
79
88
95
102
109
115
121
127
132
55
65
74
82
89
96
102
108
113
118
124
52
62
70
77
84
90
96
102
107
112
116
49
58
66
73
80
86
91
96
101
106
110
47
56
63
70
76
82
87
92
97
101
105
75
88
100
111
120
129
137
145
153
160
167
69
82
93
102
111
120
127
135
141
148
154
65
76
87
96
104
112
119
126
132
138
144
61
72
82
90
98
105
112
119
125
131
136
58
68
77
86
93
100
106
113
118
124
129
55
65
74
82
89
95
102
107
113
118
123
61
72
82
90
98
105
112
119
125
131
136
56
67
76
84
91
98
104
110
115
121
126
53
62
71
78
85
91
97
103
108
113
118
50
59
67
74
80
86
92
97
102
107
111
47
56
63
70
76
82
87
92
97
101
105
45
53
60
67
72
78
83
88
92
96
101
53
62
71
78
85
91
97
103
108
113
118
49
58
65
72
79
85
90
95
100
105
109
46
54
61
68
74
79
84
89
94
98
102
43
51
58
64
69
75
79
84
88
92
96
41
48
55
61
66
71
75
80
84
88
91
39
46
52
58
63
67
72
76
80
83
87
47
56
63
70
76
82
87
92
97
101
105
44
52
59
65
70
76
80
85
89
94
98
41
48
55
61
66
71
75
80
84
88
91
38
46
52
57
62
67
71
75
79
83
86
37
43
49
54
59
63
67
71
75
78
82
35
41
47
52
56
60
64
68
71
75
78
43
51
58
64
69
75
79
84
88
92
96
40
47
53
59
64
69
73
78
82
85
89
37
44
50
55
60
65
69
73
76
80
83
35
42
47
52
57
61
65
68
72
75
79
33
39
45
49
54
58
61
65
68
71
75
32
38
43
47
51
55
59
62
65
68
71
40
47
53
59
64
69
73
78
82
85
89
37
44
49
55
59
64
68
72
76
79
82
35
41
46
51
56
60
64
67
71
74
77
33
38
44
48
52
56
60
63
67
70
73
31
37
41
46
50
53
57
60
63
66
69
29
35
39
44
47
51
54
57
60
63
66
37
44
50
55
60
65
69
73
76
80
83
35
41
46
51
56
60
64
67
71
74
77
32
38
43
48
52
56
60
63
66
69
72
30
36
41
45
49
53
56
59
62
65
68
29
34
39
43
47
50
53
56
59
62
65
28
33
37
41
44
48
51
54
56
59
62
35
42
47
52
57
61
65
68
72
75
79
33
38
44
48
52
56
60
63
67
70
73
30
36
41
45
49
53
56
59
62
65
68
29
34
38
43
46
50
53
56
59
62
64
27
32
37
40
44
47
50
53
56
58
61
26
31
35
38
42
45
48
51
53
56
58
12
14
16
18
20
22
Vmax = Effective wind velocity based
on strength or overturning.
h = Distance from support
surface to centroid of
EPA.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
257
Phone (309) 566-3000 Fax (309)566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - BRM4
RM
B R M4
N ON - P E N E T R AT I N G
Mount Part No.
BRM425
BRM430
BRM435
BRM440
BRM445
BRM455
BRM42510
BRM43510
BRM44510
Mast Part No.
KY1590
KY1592
KY1594
KY1596
KY1598
KY1600
KY2061
KY2063
KY2065
Mast Description & Height
2.38 O.D. x 0.154 wall x 3.0
2.88 O.D. x 0.203 wall x 3.0
3.50 O.D. x 0.216 wall x 3.0
4.00 O.D. x 0.226 wall x 3.0
4.50 O.D. x 0.237 wall x 3.0
5.56 O.D. x 0.258 wall x 3.0
2.38 O.D. x 0.154 wall x 10.0
3.50 O.D. x 0.216 wall x 10.0
4.50 O.D. x 0.237 wall x 10.0
MAST SPECIFICATIONS
6.5
Square
The BRM4 mount is hot-dip galvanized after fabrication for corrosion protection.
Order (1) optional BRM4MAT (1/8 thick) or (1) optional
BRM4PAD (3/8 thick) for a protective barrier between
the mount and the roof. Order (1) optional SCK150
safety cable kit (3/8 x 150).
Refer to pages 258-259 for ballast requirements.
2.38 to 5.56 Mast Tube Diameters
3 and 10 Overall Mast Heights
(See Mast Descriptions)
16 Nominal Blocks
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - B R M4
258
2011 ROHN PRODUCTS LLC
RM
B R M4
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=2 FT h=3 FT h=4 FT h=5 FT h=6 FT h=7 FT h=8 FT h=9 FT
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
171
221
261
296
328
356
383
407
431
453
474
121
156
185
210
232
252
271
288
305
320
335
99
128
151
171
189
206
221
235
249
261
274
86
110
131
148
164
178
191
204
215
226
237
77
99
117
133
147
159
171
182
193
203
212
70
90
107
121
134
145
156
166
176
185
193
242
313
370
416
448
478
506
533
558
583
604
171
221
262
294
317
328
358
377
395
412
427
140
181
214
240
259
276
292
308
322
336
349
121
157
185
208
224
239
253
267
279
291
302
108
140
166
186
201
214
226
238
250
261
270
99
128
151
170
183
195
207
218
228
238
247
198
256
302
340
366
391
414
435
456
476
493
140
181
214
240
259
276
292
308
322
336
349
114
148
175
196
211
225
239
251
263
275
285
99
128
151
170
183
195
207
218
228
238
247
89
114
135
152
164
175
185
195
204
213
220
81
104
123
139
149
159
169
178
186
194
201
171
221
262
294
317
338
358
377
395
412
427
121
157
185
208
224
239
253
267
279
291
302
99
128
151
170
183
195
207
218
228
238
247
86
111
131
147
159
169
179
188
197
206
213
77
99
117
132
142
151
160
169
177
184
191
70
90
107
120
129
138
146
154
161
168
174
153
198
234
263
284
302
320
337
353
369
382
108
140
166
186
201
214
226
238
250
261
270
89
114
135
152
164
175
185
195
204
213
220
77
99
117
132
142
151
160
169
177
184
191
69
89
105
118
127
135
143
151
158
165
171
63
81
96
107
116
123
131
138
144
150
156
140
181
214
240
259
276
292
308
322
336
349
99
128
151
170
183
195
207
218
228
238
247
81
104
123
139
149
159
169
178
186
194
201
70
90
107
120
129
138
146
154
161
168
174
63
81
96
107
116
123
131
138
144
150
156
57
74
87
98
106
113
119
126
132
137
142
130
167
198
223
240
256
271
285
299
312
323
92
118
140
157
169
181
191
201
211
220
228
75
97
114
128
138
148
156
165
172
180
186
65
84
99
111
120
128
135
142
149
156
161
58
75
89
100
107
114
121
127
134
139
144
53
68
81
91
98
104
111
116
122
127
132
121
157
185
208
224
239
253
267
279
291
302
86
111
131
147
159
169
179
188
197
206
213
70
90
107
120
129
138
146
154
161
168
174
61
78
93
104
112
120
127
133
140
146
151
54
70
83
93
100
107
113
119
125
130
135
49
64
76
85
92
98
103
109
114
119
123
114
148
175
196
211
225
239
251
263
275
285
81
104
123
139
149
159
169
178
186
194
201
66
85
101
113
122
130
138
145
152
159
164
57
74
87
98
106
113
119
126
132
137
142
51
66
78
88
95
101
107
112
118
123
127
47
60
71
80
86
92
97
103
107
112
116
2
4
6
8
10
12
Vmax = Effective wind velocity based
on strength or overturning.
h = Distance from support
surface to centroid of
EPA.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
259
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - BRM4
RM
B R M4
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=2 FT h=3 FT h=4 FT h=5 FT h=6 FT h=7 FT h=8 FT h=9 FT
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
300
500
700
900
1100
1300
1500
1700
1900
2100
2300
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
7.1
11.8
16.6
21.3
26.0
30.8
35.5
40.2
45.0
49.7
54.4
65
84
99
112
124
135
145
154
163
171
179
61
78
92
105
116
126
135
144
152
160
168
57
74
87
99
109
119
128
136
144
151
158
54
70
83
94
104
113
121
129
136
143
150
52
67
79
89
99
107
115
123
130
137
143
49
64
75
86
95
103
110
118
124
131
137
92
118
140
157
169
181
191
201
211
220
228
86
111
131
147
159
169
179
188
197
206
213
81
104
123
139
149
159
169
178
186
194
201
77
99
117
132
142
151
160
169
177
184
191
73
94
112
126
135
144
153
161
168
176
182
70
90
107
120
129
138
146
154
161
168
174
75
97
114
128
138
148
156
165
172
180
186
70
90
107
120
129
138
146
154
161
168
174
66
85
101
113
122
130
138
145
152
159
164
63
81
96
107
116
123
131
138
144
150
156
60
77
91
102
110
118
125
131
137
143
149
57
74
87
98
106
113
119
126
132
137
142
65
84
99
111
120
128
135
142
149
156
161
61
78
93
104
112
120
127
133
140
146
151
57
74
87
98
106
113
119
126
132
137
142
54
70
83
93
100
107
113
119
125
130
135
52
67
79
89
96
102
108
114
119
124
129
49
64
76
85
92
98
103
109
114
119
123
58
75
89
100
107
114
121
127
134
139
144
54
70
83
93
100
107
113
119
125
130
135
51
66
78
88
95
101
107
112
118
123
127
48
63
74
83
90
96
101
107
112
117
121
46
60
71
79
86
91
97
102
106
111
115
44
57
68
76
82
87
92
97
102
106
110
53
68
81
91
98
104
111
116
122
127
132
49
64
76
85
92
98
103
109
114
119
123
47
60
71
80
86
92
97
103
107
112
116
44
57
68
76
82
87
92
97
102
106
110
42
54
64
72
78
83
88
93
97
101
105
40
52
62
69
75
80
84
89
93
97
101
49
63
75
84
91
97
102
108
113
118
122
46
59
70
79
85
90
96
101
106
110
114
43
56
66
74
80
85
90
95
100
104
108
41
53
63
70
76
81
86
90
94
99
102
39
50
60
67
72
77
82
86
90
94
97
37
48
57
64
69
74
78
82
86
90
93
46
59
70
79
85
90
96
101
106
110
114
43
55
65
74
79
85
90
94
99
103
107
40
52
62
69
75
80
84
89
93
97
101
38
49
59
66
71
76
80
84
88
92
95
37
47
56
63
68
72
76
80
84
88
91
35
45
53
60
65
69
73
77
81
84
87
43
56
66
74
80
85
90
95
100
104
108
40
52
62
69
75
80
84
89
93
97
101
38
49
58
65
70
75
80
84
88
92
95
36
47
55
62
67
71
75
79
83
87
90
34
44
53
59
64
68
72
76
79
83
86
33
43
50
57
61
65
69
73
76
79
82
14
16
18
20
22
24
Vmax = Effective wind velocity based
on strength or overturning.
h = Distance from support
surface to centroid of
EPA.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - B R M6
260
2011 ROHN PRODUCTS LLC
RM
10
Square
B R M6
N ON - P E N E T R AT I N G
Mount Part No.
BRM630M
BRM635M
BRM640M
BRM645M
BRM655M
BRM665M
BRM64510M
Mast Description & Height
2.88 O.D. x 0.203 wall x 4.0
3.50 O.D. x 0.216 wall x 4.0
4.00 O.D. x 0.226 wall x 4.0
4.50 O.D. x 0.237 wall x 4.0
5.56 O.D. x 0.258 wall x 4.0
6.63 O.D. x 0.280 wall x 4.0
4.50 O.D. x 0.237 wall x 10.0
MAST SPECIFICATIONS
Mast Part No.
KY2110
KY1570
KY1578
KY1579
KY1580
KY1581
KY2043
The BRM6 mount is hot-dip galvanized after fabrication for corrosion protection.
Order (1) optional BRM6MAT (1/8 thick) or (1) optional BRM6PAD (3/8 thick)
for a protective barrier between the mount and the roof. Order (1) optional
SCK150 safety cable kit (3/8 x 150).
Optional additional inner ballast support angle kit available, order P/N BRM6ABK.
Refer to pages 261-263 for ballast requirements.
2.88 to 6.63 Mast Tube Diameters
4 and 10 Overall Mast Heights
(See Mast Descriptions)
16 Nominal Blocks
261
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - BRM6
RM
B R M6
4 F T. D I S H E L E VAT I ON
B A L L A S T R E QU I R E ME N T S
Dish
Diameter
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Design Wind Velocities
(MPH)
EL=0 EL=20 EL=40
500
750
1000
1250
1500
1750
2000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
4
(1.2 m)
6
(1.8 m)
8
(2.4 m)
Vmax Vs Vmax Vs Vmax Vs
5.0
7.5
10.0
12.5
15.0
17.5
20.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
87
107
125
139
148
157
165
58
71
83
93
99
105
110
115
120
125
127
53
62
69
74
78
82
86
90
94
95
67
82
95
106
117
126
135
45
55
63
71
78
84
90
95
100
105
110
41
47
53
58
63
67
71
75
79
82
103
131
154
169
180
190
196
65
83
99
112
120
127
130
130
130
130
130
57
69
79
85
91
97
98
98
98
98
75
92
107
119
131
141
151
50
61
71
79
87
94
101
107
113
118
123
46
53
59
65
70
75
80
84
88
92
112
142
167
189
203
211
211
69
89
106
120
129
137
141
141
141
141
141
60
73
84
90
96
102
103
103
103
103
92
113
131
146
160
173
185
61
75
87
97
107
115
123
131
138
141
141
56
65
73
80
86
92
98
103
103
103
Vmax = Effective wind velocity based
on strength or overturning.
EL = Dish antenna azimuth angle with
horizontal.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - B R M6
262
2011 ROHN PRODUCTS LLC
RM
B R M6
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=4 FT h=5 FT h=6 FT h=7 FT h=8 FT h=9 FT h=10 FT
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
99
121
140
156
171
185
198
210
221
232
242
81
99
114
128
140
151
161
171
180
189
198
70
86
99
110
121
131
140
148
156
164
171
63
77
88
99
108
117
125
133
140
147
153
57
70
81
90
99
107
114
121
128
134
140
53
65
75
84
91
99
106
112
118
124
129
128
156
180
202
218
230
242
254
265
275
280
104
128
147
165
178
188
198
207
216
225
228
90
110
128
143
154
163
171
179
187
195
198
81
99
114
128
138
146
153
160
167
174
177
74
90
104
116
126
133
140
147
153
159
161
68
84
96
108
116
123
130
136
141
147
149
114
140
161
180
195
206
217
227
237
246
250
93
114
132
147
159
168
177
185
193
201
204
81
99
114
128
138
146
153
160
167
174
177
72
88
102
114
123
130
137
144
150
156
158
66
81
93
104
113
119
125
131
137
142
144
61
75
86
96
104
110
116
121
127
132
134
104
128
147
165
178
188
198
207
216
225
228
85
104
120
134
145
154
162
169
176
183
186
74
90
104
116
126
133
140
147
153
159
161
66
81
93
104
113
119
125
131
137
142
144
60
74
85
95
103
109
114
120
125
130
132
56
68
79
88
95
101
106
111
115
120
122
96
118
136
152
165
174
183
192
200
208
211
79
96
111
125
134
142
150
157
163
170
173
68
84
96
108
116
123
130
136
141
147
149
61
75
86
96
104
110
116
121
127
132
134
56
68
79
88
95
101
106
111
115
120
122
52
63
73
82
88
93
98
103
107
111
113
90
110
128
143
154
163
171
179
187
195
198
74
90
104
116
126
133
140
147
153
159
161
64
78
90
101
109
115
121
127
132
138
140
57
70
81
90
97
103
108
113
118
123
125
52
64
74
82
89
94
99
104
108
112
114
48
59
68
76
82
87
92
96
100
104
106
85
104
120
134
145
154
162
169
176
183
186
69
85
98
110
119
125
132
138
144
150
152
60
74
85
95
103
109
114
120
125
130
132
54
66
76
85
92
97
102
107
112
116
118
49
60
69
78
84
89
93
98
102
106
108
45
56
64
72
78
82
86
90
94
98
100
81
99
114
128
138
146
153
160
167
174
177
66
81
93
104
113
119
125
131
137
142
144
57
70
81
90
97
103
108
113
118
123
125
51
63
72
81
87
92
97
101
106
110
112
47
57
66
74
80
84
89
93
97
100
102
43
53
61
68
74
78
82
86
89
93
94
10
15
20
25
30
35
Vmax = Effective wind velocity based
on strength or overturning.
EL = Dish antenna angle with
horizontal.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
263
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - BRM6
RM
B R M6
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
(MPH)
Vmax at centroid of projected area, (MPH)
h=4 FT h=5 FT h=6 FT h=7 FT h=8 FT h=9 FT h=10 FT
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
49
61
70
78
86
92
99
105
110
116
121
47
57
66
74
81
87
93
99
104
109
114
44
54
63
70
77
83
88
94
99
104
108
64
78
90
101
109
115
121
127
132
138
140
60
74
85
95
103
109
114
120
125
130
132
57
70
81
90
97
103
108
113
118
123
125
57
70
81
90
97
103
108
113
118
123
125
54
66
76
85
92
97
102
107
112
116
118
51
63
72
81
87
92
97
101
106
110
112
52
64
74
82
89
94
99
104
108
112
114
49
60
69
78
84
89
93
98
102
106
108
47
57
66
74
80
84
89
93
97
100
102
48
59
68
76
82
87
92
96
100
104
106
45
56
64
72
78
82
86
90
94
98
100
43
53
61
68
74
78
82
86
89
93
94
45
55
64
71
77
81
86
90
94
97
99
43
52
60
67
73
77
81
85
88
92
93
40
49
57
64
69
73
77
80
84
87
88
43
52
60
67
73
77
81
85
88
92
93
40
49
57
63
68
72
76
80
83
86
88
38
47
54
60
65
69
72
76
79
82
83
40
49
57
64
69
73
77
80
84
87
88
38
47
54
60
65
69
72
76
79
82
83
36
44
51
57
62
65
69
72
75
78
79
40
45
50
Vmax = Effective wind velocity based
on strength or overturning.
EL = Dish antenna angle with
horizontal.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - NP P K
264
2011 ROHN PRODUCTS LLC
RM
NP P K
N ON - P E N E T R AT I N G
3.4
Mount Adjusts to
Roof Angle
The NPPK mount is a great solution for broadband antennas and satellite TV dishes. The adjustable mounting plate can be center
mounted or to one side as needed to accommodate other satellite TV dish mounts. Our 1LG mount (located on page 274) with a
base and 1-1/4 mounting tube can be attached to the NPPK. The mount comes standard with double ballast trays on each side to
hold concrete blocks. The NPPK mount is hot-dip galvanized after fabrication for corrosion protection.
Order (2) optional FRMMAT (1/8 thick) or (2) optional FRMPAD (3/8 thick) for a protective barrier between the mount and the roof.
Order (1) optional SCK150 safety cable kit (3/8 x 150).
3
Adjustable
Mounting Plate
16 Nominal
Blocks
265
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - 25GBRM
RM
2 5 GB R M
N ON - P E N E T R AT I N G
The 25GBRM mount is designed to support one or two 25G tower sections in a self-supporting application. The 25GBRM mount
is galvanized after fabrication for corrosion protection.
Order (1) optional BRM6MAT (1/8 thick) or (1) optional BRM6PAD (3/8 thick) for a protective barrier between the mount and the
roof. Order (1) optional SCK150 safety cable kit (3/8 x 150).
Refer to page 266 for ballast requirements.

Standard 25G sections mount
to top of 25GBRM
10 Square
Overall Mast Heights
(1) 25G Section - 12.4
(2) 25G Sections - 22.4
16 Nominal Blocks
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - 2 5 GB R M
266
2011 ROHN PRODUCTS LLC
RM
2 5 GB R M
B A L L A S T R E QU I R E ME N T S
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
One
Section
(MPH)
h=12.4 FT
Vmax at centroid of
projected area, (MPH)
Vs
Two
Sections
(MPH)
h=22.4 FT
1 Section
h=12.4 FT
2 Sections
h=22.4 FT
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
131
160
185
207
227
245
250
250
250
250
250
113
138
159
178
195
211
225
239
250
250
250
100
123
142
159
174
188
201
213
224
235
246
91
112
129
144
158
171
183
194
204
214
224
84
103
119
133
146
158
169
179
189
198
207
79
97
112
125
137
148
158
167
176
185
193
96
117
135
151
165
179
191
203
214
224
234
88
107
124
139
152
164
175
186
196
206
215
82
100
115
129
141
152
163
173
182
191
200
76
94
108
121
132
143
153
162
171
179
187
72
89
102
114
125
135
145
153
162
169
177
69
84
97
109
119
128
137
146
154
161
168
111
136
157
176
190
201
211
221
231
240
244
92
112
130
145
157
166
174
182
190
198
201
80
98
113
126
136
144
152
159
166
172
175
72
88
101
113
122
129
136
142
149
154
157
66
80
93
104
112
118
124
130
136
141
144
61
74
86
96
104
110
115
121
126
131
133
65
80
92
103
111
118
124
130
135
140
143
57
70
81
91
98
104
109
114
119
124
126
52
63
73
82
88
94
98
103
107
112
113
48
58
67
75
81
86
90
95
99
103
104
44
54
63
70
76
80
84
88
92
95
97
42
51
59
66
71
75
79
83
86
90
91
2
4
6
8
10
12
Effective
Projected
Area (EPA)
(FT )
2
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vs
One
Section
(MPH)
h=12.4 FT
Vmax at centroid of
projected area, (MPH)
Vs
Two
Sections
(MPH)
h=22.4 FT
1 Section
h=12.4 FT
2 Sections
h=22.4 FT
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
74
91
105
117
129
139
149
158
166
174
182
70
86
100
111
122
132
141
149
157
165
172
67
82
95
106
116
126
134
142
150
157
164
66
80
93
104
114
123
131
139
147
154
161
63
77
89
99
109
118
126
133
141
147
154
60
74
86
96
105
113
121
128
135
142
148
57
70
80
90
97
103
108
113
118
123
125
54
66
76
85
92
97
102
107
111
116
118
51
62
72
81
87
92
97
101
106
110
112
39
48
56
62
67
71
75
78
81
85
86
37
46
53
59
64
67
71
74
77
80
82
36
44
50
56
61
64
68
71
74
77
78
14
16
18
h = Distance from support surface to centroid of EPA.
Vs = Effective wind velocity resulting in sliding on a flat surface
with a .50 coefficient of friction.
Vmax = Effective wind velocity based on strength or overturning.
267
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - AAGM
RM
A AGM
N ON - P E N E T R AT I N G
Mount Part No.
AAGM35
AAGM40
AAGM45
AAGM55
AAGM6560
Mast Part No.
FYS75
FYS76
FYS77
FYS78
FYS96
Mast Description & Height
3.50 O.D. x 0.216 wall x 4.5
4.00 O.D. x 0.226 wall x 4.5
4.50 O.D. x 0.237 wall x 4.5
5.56 O.D. x 0.258 wall x 4.5
6.63 O.D. x 0.280 wall x 5.0
MAST SPECIFICATIONS
16.3
14.3
The AAGM mount is capable of supporting dishes with diameters up to 10 feet. The AAGM mount is hot-dip galvanized after
fabrication for corrosion protection.
Order (1) optional AGMMAT (1/8 thick) or (1) optional AGMPAD (3/8 thick) for a protective barrier between the mount and the roof.
Order (1) optional SCK150 safety cable kit (3/8 x 150).
Refer to page 268 for ballast requirements.
3.50 to 6.63 Mast Tube Diameters
2.5 and 5 Overall Mast Heights
(See Mast Descriptions)
16 Nominal Blocks
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - A AGM
268
2011 ROHN PRODUCTS LLC
RM
A AGM
4 . 5 F T D I S H E L E VAT I ON
B A L L A S T R E QU I R E ME N T S
Dish
Diameter
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Vmax
(MPH)
Vs (MPH)
EL=0 EL=20 EL=40
1000
1500
2000
2500
3000
3500
4000
5000
6000
1000
1500
2000
2500
3000
3500
4000
5000
6000
1000
1500
2000
2500
3000
3500
4000
5000
6000
1000
1500
2000
2500
3000
3500
4000
5000
6000
4
(1.2 m)
6
(1.8 m)
8
(2.4 m)
10
(3.0 m)
6.0
9.0
12.0
15.1
18.1
21.1
24.1
30.1
36.1
6.0
9.0
12.0
15.1
18.1
21.1
24.1
30.1
36.1
6.0
9.0
12.0
15.1
18.1
21.1
24.1
30.1
36.1
6.0
9.0
12.0
15.1
18.1
21.1
24.1
30.1
36.1
135
164
187
207
225
240
250
250
250
90
109
125
138
150
160
165
165
165
68
82
94
104
112
120
125
125
125
46
56
64
71
77
82
85
85
85
91
111
128
143
157
170
181
203
222
60
74
85
96
105
113
121
135
148
45
56
64
72
79
85
91
101
111
31
38
44
49
54
58
62
69
76
93
114
132
147
161
174
186
208
228
62
76
88
98
108
116
124
139
152
47
57
66
74
81
87
93
104
114
33
40
46
52
57
61
65
73
80
101
123
142
159
174
188
201
225
246
67
82
95
106
116
125
134
150
164
50
62
71
79
87
94
101
112
123
40
49
57
64
70
75
80
85
85
Vmax = Effective wind velocity based
on strength or overturning.
EL = Dish antenna azimuth angle with
horizontal.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
269
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - PRM6
RM
P R M6
N ON - P E N E T R AT I N G
Mount Part No.
PRM635
PRM640
PRM645
PRM655
Mast Description
3.50 O.D. x 0.216 wall
4.00 O.D. x 0.226 wall
4.50 O.D. x 0.237 wall
5.50 O.D. x 0.258 wall
MAST SPECIFICATIONS
Mast Part No.
KY1672
KY1673
KY1674
KY1675
2.4
10. 4
Dish
Diameter
Ballast
(LBS)
Zero
Velocity
Load
(PSF)
Design Wind Velocities
(MPH)
EL=0 EL=20 EL=40
1600
1800
2000
2200
2400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4
(1.2 m)
6
(1.8 m)
Vmax Vs Vmax Vs Vmax Vs
17.2
19.4
21.5
23.7
25.8
17.2
19.4
21.5
23.7
25.8
28.0
30.1
32.3
34.4
36.6
38.7
40.9
145
154
162
168
171
97
102
108
112
114
116
118
120
122
124
125
125
122
130
137
144
150
81
86
91
96
100
104
108
112
115
119
122
125
180
184
187
189
189
117
123
125
126
126
126
126
126
126
126
126
126
137
146
154
161
168
91
97
102
107
112
117
121
125
126
126
126
126
198
198
198
198
198
126
132
132
132
132
132
132
132
132
132
132
132
168
179
188
197
198
112
119
125
131
132
132
132
132
132
132
132
132
BALLAST REQUIREMENTS
The PRM6 mount is capable of supporting dishes with diameters up to 6 feet. The mount is hot-dip galvanized after fabrication for
corrosion protection. Th PRM6 mount is also UPS shippable.
Order (1) optional PRM6MAT (1/8 thick) or (1) optional PRM6PAD (3/8 thick) for a protective barrier between the mount and the roof.
Order (1) optional SCK150 safety cable kit (3/8 x 150).
Vmax = Effective wind velocity based
on strength or overturning.
EL = Dish antenna azimuth angle with horizontal.
Vs = Effective wind velocity resulting in sliding on
a flat surface with a .50 coefficient of friction.
NOTE: Mast strength may govern antenna capacity.
Concrete blocks not
provided with mount.
Post Tensioning
Rods (TYP)
3.50 to 5.50 Mast Tube Diameters
5.0 Overall Mast Heights
(See Mast Descriptions)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S
270
2011 ROHN PRODUCTS LLC
RM
B A L L A S T R E QUI R E ME NT S F OR R OOF MOUNT S
1. Ballast requirements are provided to assist consumers in determining the applicability of a non-penetrating roof mount
for an antenna installation and to assist in determining the amount of ballast required. The ballast requirements should
not be relied upon without competent local professional examination and verification of its accuracy and suitability for a
specific site or application.

2. Specific antennas and/or other mounting configurations may require more stringent strength and ballast requirements
and must be investigated for each installation. The load carrying requirements of the supporting surface, the mount and
mast, the antenna and the antennas connection to the mast must be investigated for each installation.

3. When antenna areas are indicated vs. specific antenna types, the areas tabulated are effective projected areas that include
appropriate wind drag factors applied to the projected areas of the supported antennas and the exposed portions of the
mount and ballast. The center of the effective projected area is assumed to be at the top of the mounting pipe or the
height indicated in the ballast table. Unless otherwise indicated, tabulated ballast requirements assume that the effective
projected areas are concentric to the mount and that uplift or download wind forces are insignificant.

4. The tabulated wind velocities are considered to occur at the centroid of the effective projected areas. The wind velocity
appropriate for an installation must be determined on an individual site basis considering the location and elevation of
the mount. The wind velocity at ground level must be multiplied by appropriate height escalation and gust factors.
Potential increases in wind velocity due to channeling, roof projections, and other obstructions, must also be considered
when determining ballast requirements.

5. The ballast weights indicated are assumed to be uniformly distributed on the mount. The weight of the mount and
antenna may be considered as ballast. Mounts are assumed to be mounted on a flat supporting surface.

6. The zero velocity loads shown are equal to the tabulated ballast weights divided by the total area enclosed by the
perimeter of the mount. This area is greater than the ballast contact area. Loads which must be investigated include
reactions caused by wind forces and moments, live loads, ice loads, earthquake loads and the dead loads of ballast, mount,
antenna, mounting hardware, miscellaneous equipment and roof pads.

7. The tabulated maximum wind velocities (Vmax) are based on a minimum 1.5 factor of safety against structural failure
and overturning.

8. The tabulated wind velocities resulting in sliding (Vs) are based on a factor of safety equal to 1.0 and an effective
coefficient of friction equal to 0.50 between the mount and a flat supporting surface. A 1.0 factor of safety was used
assuming that at higher wind velocities, safety cables or other suitable attachments to the support structure would
prevent sliding beyond a safe, designated area.

9. The appropriate coefficient of friction and factor of safety to determine wind velocities resulting in sliding must be
determined on an individual site basis. The coefficient of friction may vary under changing moisture and temperature
conditions. The minimum coefficient of friction must be used to evaluate sliding resistance. Wind speeds resulting in
sliding for other factors of safety or for other coefficients of friction may be found by multiplying the tabulated values
of Vs by the following modification factor:
Modification Factor = [ /(.5 x FS)]
1/2
= Coefficient of Friction
FS = Factor of Safety
10. The values of Vs indicated do not apply for installations which are prevented from sliding by cables or other suitable
attachments to the supporting structure.
11. Roof pads are recommended to prevent damage to roof membranes. Pads should be placed under all contact areas.
12. ROHN recommends that ballast material always be placed prior to mounting the antenna and that roof pads and mount
be secured to prevent hazards from occurring under extreme wind loading conditions. Precautions should also be taken
to prevent the inadvertent removal of ballast material after installation and to insure that all ballast material is fully
supported by the mount (required for ballast to be effective in resisting overturning and sliding).
13. When adhesives are used to secure roof pads, the adhesive must be compatible with the supporting surface. Precautions
should be taken to insure that damage to the supporting surface will not occur upon wind loading.
14. The installation, roof material and supporting structure must be capable of withstanding all loads imposed by the
antenna system. Supporting surfaces, anchors and/or safety cables must be sufficient to resist the reactions from the
antenna system. The installation must meet all applicable local, state and federal requirements.
271
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - URM
RM
UR M
Features:
1. URM mount can be used on a flat roof, sloped roof or over a roof peak.
2. URM mount can be used with 2.88 to 4.50 O.D. masts (order separately).
3. Bottom of mount pivots to match roof pitch.
4. Rear leg adjusts for extra length.
5. Mount base angles are pre-drilled to accept 1/2 diameter connectors.

Optional Masts - Ordered Separately
P2530 2.88 O.D. x 0.203 wall x 30 Long
P330 3.50 O.D. x 0.216 wall x 30 Long
P3530 4.00 O.D. x 0.226 wall x 30 Long
P430 4.50 O.D. x 0.237 wall x 30 Long
16
24 28
25
ROHNs Universal Roof Mount (URM) is capable of supporting most PCS, Cellular, and Microwave antennas. The URM adapts to
various roof pitches and the fully adjustable rear-leg allows for use on a fat or up to a 12/12 pitched roof. Installation is easy
because of the quick adaptability, plus theres no need for concrete blocks. The URM is hot-dip galvanized after fabrication for
corrosion protection, and can easily ship UPS.
Braces provided with
multiple holes to allow
+ / - 26 of length
adjustment.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
R OOF MOUNT S - S HR M
272
2011 ROHN PRODUCTS LLC
RM
S HR M
26
28
24
16
Features:
1. SHRM mount can be used on a flat roof or on a roof peak, up to 45 degrees maximum pitch.
2. SHRM mount can be used with 2.88 to 5.00 O.D. masts (ordered separately).
3. Bottom of mount pivots to match roof pitch.
4. Mount base angles are pre-drilled to accept 1/2 diameter connectors.

ROHNs Saw Horse Roof Mount (SHRM) is capable of supporting most PCS, Cellular, and Microwave antennas. The SHRM
allows for placement of antennas on fat roofs or roof peaks with up to a 12/12 pitch. The SHRM is also able to be installed on
fat roofs. Installation is easy because of the quick adaptability, plus theres no need for concrete blocks. The SHRM is hot-dip
galvanized after fabrication for corrosion protection, and can easily ship UPS.
Optional Masts - Ordered Separately
P2530 2.88 O.D. x 0.203 wall x 30 Long
P330 3.50 O.D. x 0.216 wall x 30 Long
P3530 4.00 O.D. x 0.226 wall x 30 Long
P430 4.50 O.D. x 0.237 wall x 30 Long
28
273
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
ROOF MOUNTS - TRT
RM
T R T 3 6 / T R T 6 0 / T R TAG2
Description
3 tall, tube legs (PG)
5 tall, tube legs (PG)
5 tall, angle legs (HDG)
with 2.38O.D. x 0.154 wall x 3.5 long mast (HDG)
SPECIFICATIONS
Part No.
TRT36
TRT60
TRTAG2
TRT60
The TRT is a Tripod Roof Tower, which comes fully assembled and snaps out into position for quick installation using up to 1/4 dia. connectors.
The TRTAG2 mount comes with a 2 3/8 O.D. hot-dip galvanized mast, the TRT36 and TRT60 mounts accept masts up to 1 3/4 O.D. (ordered
separately). The bolt-on swivel feet adjust to most any pitch roof. TRT mounts are galvanized for corrosion protection. All TRT mounts are
UPS shippable.
TRTAG2
TRT36
Angle leg
Tube leg
TRTAG2 comes with a 2 3/8 O.D. mast.
Masts must be ordered separately for
the TRT36 and TRT60.
Please see page 301 for mast options.
TRT36 and TRT60 ft ROHNs
Telescoping masts
(see pages 244-249).
PG = Pre-galvanized
HDG = Hot-dip galvanized
Mast
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
274
NOT E S
1 L G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
WA L L MOUNT S - 1 L G
276
2011 ROHN PRODUCTS LLC
WM
The Universal One-Legged Mount (1LG) may be the one and only mount that can be installed on any part of any building. This
mount is designed for many types of antennas home, TV, MMDS, DBS and more. The mount has a 1-1/4 O.D. mounting pipe
and includes (4) 1/4 dia. x 2 long lag screws for installation. The mount is galvanized for corrosion protection and goes together
quickly. The mount is easily shipped via UPS.
7
1
2

115
o
1.25 O.D. x 16GA
Mounting Tube
277
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
P WM
WALL MOUNTS - PWM
36
WM
The ROHN Pole Wall Mount (PWM) is designed to support most Satellite, PCS, Cellular, and Microwave antennas. The PWM
allows you to vary the mounting pipe length and diameter, accepting 2 7/8 O.D. - 5 O.D. mounting tubes. The PWM is
hot-dip galvanized after fabrication for corrosion protection, and can easily be shipped UPS.
Adjustable mast ofset
from wall at 16, 22 and 28
Optional inside
mounting angles,
ordered separately.
P/N: FY77
(2) required
for mounting
inside
Optional hardware
mounting kit
P/N: HMK18M
Includes: (4) 1/2 dia. x 18
threaded rods and sealant.
32
WM4
Single: Wall Clearance
WM6S 6 clearance
WM8S 8 clearance
WM12S 12 clearance
WM18S 18 clearance
WM24S 24 clearance
Double: Wall Clearance
WM8D 8 clearance
WM12D 12 clearance
WM18D 18 clearance
WM24D 24 clearance
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
WA L L MOUNT S
278
2011 ROHN PRODUCTS LLC
WM
WM212
Single and double extended wall mount assemblies can be used on masonry, wood, metal,
and other types of walls using up to 1/4 dia. lag screws or bolts. The Wall Mounts are
versatile, coming in a variety of stand of lengths and supporting 7/8 to 2 3/4 O.D. masts.
The mounts are available as single brackets or double brackets. Masts are held in place with
a unique Anti-Twist locking clamp. Galvanized for durability, these Wall Mounts are UPS shippable.
Clamp Accepts 7/8 to 2 3/4 O.D.
Mast Tube Diameters, mast
ordered separately.
WMB12A
Optional diagonal
strap kit, ordered
separately.
Anti-Twist Locking Screw
WM2 1 2
The WM212 mount provides 12 clearance to the wall. The WM212 is hot-dip
galvanized for corrosion protection. Optional WMB12A diagonal is available
to provide extra strength. Mount is pre-drilled to accept 1/2 dia. connectors.
E X T E NDE D WA L L MOUNT A S S E MB L I E S
2 3/8 O.D. x 0.154 wall x 6 long
Mounting Tube, provided
with mount.
WM4
Single: Upper Bracket only
Double: Upper
and Lower Bracket
Clamp Accepts 7/8 to 2 3/4 O.D.
Mast Tube Diameters, mast
ordered separately.
Anti-Twist Locking Screw
2.38 O.D. x 0.154 wall
NOTE: Connectors to wall not included.
See page 301 for Mast options.
The WM4 mount provides 3 clearance to the wall. The WM4 is hot-dip galvanized
for corrosion protection. Masts are held in place with a unique Anti-Twist locking
clamp. This mount includes (4) 1/4 dia. x 2 long lag screws for mounting.
279
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
G- SERI ES WALL MOUNTS
WM
HB UT V R O
The HBUTVRO provides lateral support for 25G, 45G and 55G
bracketed towers.
The bracket is pre-drilled to accept 5/8 dia.
connectors to wall at 16 or 24 spacing.
Adjustable to position tower 18 - 36 from wall.
The 25GWM upper bracket provides lateral support for 25G wall supported
towers. The lower bracket provides both lateral and vertical support. The 25G
base plate (P/N KH6775, not shown) is provided with mount to provide an
adjustable 6 - 20 of clearance to wall.
The brackets are pre-drilled to accept 5/8 dia. connectors at 16 or 24
spacing. A minimum 5 separation between the top and bottom brackets
is recommended.
K H1 0 1 4
F OR 6 5 G B R A C K E T E D T OWE R S
The KH1014 bracket provides lateral support for 65G
bracketed towers.
The brackets are pre-drilled to accept 3/4 dia. connectors
to wall at various center-to-center spacings (4.75 increments).
Adjustable to position tower 18 - 30 from wall.
G- S E R I E S WA L L B R AC K E T S & B A S E MOUNT S
2 5 GWM
F OR 2 5 G WA L L S U P P OR T E D T OWE R S
All mounts shown are hot-dip galvanized.
60
27
7
4

6
0

Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
280
NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
M
T OWE R MODI F I C AT I ON MAT E R I A L - GUY E D T OWE R S
282
2011 ROHN PRODUCTS LLC
Item
1
2
3
4
5
Qty.
3
3
6
9
3
Part No.
KC144
KC465
210050GA
210059GA
KC441
Description
Bar Flat Bracket Guy .38 x 5 x 4.5
Bar Flat TA .38 x 3.5 x1.83
Bolt Assembly 3/4 x 2-3/4 HSB A325
Bolt Assembly 3/4 x 5-1/2 HSB A325
Spacer Bracket Guy .63 x 3.13 x 4.5
5
GA85 Bill of Material
R OHN MODE L 8 0 GUY E D T OWE R
S TA N D A R D G U Y B R A C K E T S F OR 8 3 & 8 4 S E C T I ON S
( 2 3 / 8 & 2 7 / 8 O. D. L E G S )
Item
1
2
3
4
Qty.
3
3
6
9
Part No.
KC143
KC145
210047GA
210058GA
Description
Bar Flat Bracket Guy .38 x 4.5 x4.5
Bar Flat TA 2.75 x .38 x 1.82
Bolt Assembly 3/4 x 2 HSB A325
Bolt Assembly 3/4 x 5 HSB A325
Torque Bar Shown
1
2
3
4
Tower Brace (REF)
These guy brackets are designed for 5/8 EHS maximum guys at 80% guy
radius. For use on ROHN Model 80 tower only, supported on brace clips.
For single braced standard sections, guy bracket must be used at the top
of the section.
For double braced standard sections, guy brackets may be used at any panel
point.
GA80 Bill of Material
*
Torque Bar Shown
1
2
3
4
Tower Brace (REF)
*
5
These guy brackets are designed for 5/8 EHS maximum guys at 80% guy
radius. For use on ROHN Model 80 tower only.
For single braced standard sections, guy bracket must be used at the top
of the section.
For double braced standard sections, guy brackets may be used at any panel
point.
R OHN MODE L 8 0 GUY E D T OWE R
S TA N D A R D G U Y B R A C K E T S F OR 8 5 S E C T I ON S
( 3 1 / 2 O. D. L E G S )
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R MODI F I C AT I ON MAT E R I A L - GUY E D T OWE R S
283
2011 ROHN PRODUCTS LLC
M
T OR QUE A R M
C H A N N E L A S S E MB LY F OR 8 0 T OWE R S
NOTE: For single braced sections, torque arm must bear on brace clips above flange plates. For double braced sections,
torque arm must bear on brace clips at any panel point.
Tower
Leg Clamp
Bolt Assembly with
Beveled Washers
Equalizer Plate
Tower Leg
Bolt Assembly
Bottom Plate
Bolt Assembly with
Beveled Washers
Available Sizes:
10 Channel (C10x15.3)
12 Channel (C12x20.7)
15 Channel (C15x33.9)
To order, provide leg size and desired channel size.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R MODI F I C AT I ON MAT E R I A L - GUY E D T OWE R S
2011 ROHN PRODUCTS LLC
M
284
R E I NF OR C E ME NT S F OR 8 0 S E R I E S T OWE R S
S TA N D A R D PA R T S AVA I L A B L E F OR T OWE R MOD I F I C AT I ON S
A N D F I E L D R E I N F OR C E ME N T
Detail of bolt-on midspan horizontal brace.
Detail of horizontal girt.
Added braces are shown as a bold line.
To order, provide leg size and size of horizontal desired.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R MODI F I C AT I ON MAT E R I A L - GUY E D T OWE R S
2011 ROHN PRODUCTS LLC
M
285
R E I NF OR C E ME NT S F OR 8 0 S E R I E S T OWE R S
S TA N D A R D PA R T S AVA I L A B L E F OR T OWE R MOD I F I C AT I ON S
A N D F I E L D R E I N F OR C E ME N T
For 80 Series towers
For 80/90 Series towers
Detail of bolt-on lug.
Detail of bolt-on midspan horizontal bracket.
Added braces are shown as a bold line.
Standard and Heavy Duty replacement braces are
available. To order heavy duty braces, specify leg size
and desired brace size.
Lug P/N (1)
KB299
KB299SP
KB489
KB489SP
KB489SP1
KB492
U-Bolt Assy.(4)
JR83A
JR84A
JR84A
JR88A
JR89A
JR88A
X-Brace Lug Requirements (Pipe)
Leg O.D.
2.38
2.38
2.88
2.88
2.88
3.50
Assy.P/N
KB497A
KB497ASP
KB498A
KB498ASP
KB498ASP1
KB499A
Lug P/N (1)
KB555
KB556
KB557
KB558
KB559
U-Bolt Assy.(4)
JR83A
JR83A
JR84A
JR84A
JR88A
X-Brace Lug Requirements (Solid Rod)
Leg O.D.
2.25
2.50
2.75
3.00
3.25
Assy.P/N
KB565A
KB566A
KB567A
KB568A
KB569A
Bracing (16 GA)
Part No.
KB35R
KB36R
210018GA
Description
1.50 Tube,16GA Diagonal
1.50 Tube,16GA Horizontal
1/2 x 1-1/2 A325 Bolt Assy.
Bracing (11 GA)
Part No.
KB37R
KB38R
210019GA
Description
1.50 Tube,11GA Diagonal
1.50 Tube,11GA Horizontal
1/2 x 1-3/4 A325 Bolt Assy.
Detail of bolt-on horizontal brace.
Standard Bracing Available
Similar reinforcements available for 90 series towers.
Girt Support
Bracket
Tower Leg
(Ref )
1/2 Leg
U-bolt
Diagonal Tower
Braces
Bolt
Assembly
Center Plate
Horizontal Girt
(Typ)
S E L F - S UP P OR T I NG R E I NF OR C E ME NT S
S TA N D A R D PA R T S AVA I L A B L E F OR T OWE R MOD I F I C AT I ON S
A N D F I E L D R E I N F OR C E ME N T
Bolt on brackets are available for all SSV towers.
Girt Support Bracket
1/2 Leg
U-Bolt
Bolt
Assemblies
Diagonal Tower
Braces (Ref )
Center Plate
Horizontal Girt (Typ)
VIEW A-A
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
TOWER MODIFICATION MATERIAL - SELF-SUPPORTING TOWERS
286
2011 ROHN PRODUCTS LLC
M
Added horizontal
girt to increase leg
capacity (TYP)
U-bolt Connection
(Typical)
Added redundants to
increase brace and leg
capacity (TYP)
S S MW S E L F - S UP P OR T I NG R E I NF OR C E ME NT S
S TA N D A R D PA R T S AVA I L A B L E F OR T OWE R MOD I F I C AT I ON S
A N D F I E L D R E I N F OR C E ME N T
TOWER MODIFICATION MATERIAL - SELF-SUPPORTING TOWERS
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
287
M
INTERNAL TOWER VIEW
(Hip Bracing)
Bolt-on brackets are available for all
SSMW legs and internal braces.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R MODI F I C AT I ON MAT E R I A L
288
2011 ROHN PRODUCTS LLC
M
SIZE & TYPE
ULTIMATE
STRENGTH
(LBS)
SIZE
ULTIMATE
STRENGTH
(LBS)
3/16EHS
1/4EHS
5/16EHS
3/8EHS
7/16EHS
1/2EHS
9/16EHS
5/8EHS
3/4EHS
3990
6650
11200
15400
20800
26900
35000
42400
58300
6000
11000
17500
17500
26000
36000
36000
50000
76000
GAR
GAR
GAR
GAR
GAC34
GAC34
GAC34
GAC34
GAC56
GAC56
GAC56
GAC56
GAC56
GAC57
GAC57
GAC57
GAC57 GAC58
GAC58
GAC59
GAC59
GUY A NC HOR S E L E C T I ON C HA R T
ANCHOR RODS COMPATIBLE WITH TURNBUCKLE SIZE
ANCHOR RODS
Part No.
GAR30
GAC303
GAC305
GAC3455TOP
GAC5655TOP
GAC5755TOP
GAC5855TOP
GAC5955TOP
L
84
84
84
84
120
168
192
240
A
1
2
2
2
2-1/2
3
4
4
B
-
-
-
12
12
12
12
18
C
2
1
1
1
1-1/4
1-3/8
1-3/4
1-3/4
D
5/8
5/8
5/8
3/4
1-1/4
1-7/16
1-1/4
1-7/16
T
-
3/16
3/16
3/8
1/2
3/4
1
1
Weight (lbs.)
9
13
14
25
65
125
220
310
Type
GAR
GAC
GAC
GAC34
GAC56
GAC57
GAC58
GAC59
GAC303
(3) 9/16HOLES
GAC305
(5) 9/16HOLES
A A
T
T
A
5-1/4"
C
L
L L
GAR30
GAC3455TOP
(5) 11/16HOLES
GAC5655TOP
(5) 13/16HOLES
GAC5755TOP
(5) 15/16HOLES
GAC5855TOP
(5) 1-3/16HOLES
GAC5955TOP
(5)1-3/16HOLES
A
L
5-1/4"
(2) 3/16
plates, one
on each
side
D D
D D
B B
GAR30
Anchor
Rod
C
3/4dia.
bolt
included
C C
NOTE: GAC Anchors require use of eye and eye turnbuckles. All other anchors are for
use with eye and jaw turnbuckles. Refer to page 297.
3/8
1/2
5/8
5/8
3/4
7/8
7/8
1
1-1/4
GAC
GAC
GAC
1/2dia.
bolts
provided
GUYS TURNBUCKLES
NUT S , B OLT S & WA S HE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
290
2011 ROHN PRODUCTS LLC
H
Dia. x Length (inches)
5/16 x 2-3/8
3/8 x 1-1/4
3/8 x 1-1/2
3/8 x 2
3/8 x 2-1/2
3/8 x 2-1/2 (Full Thread)
3/8 x 4
3/8 x 4 (Full Thread)
7/16 x 2-1/2
5/8 x 1-3/4
5/8 x 2
5/8 x 3-1/4
5/8 x 3-3/4
3/4 x 4-1/2
7/8 x 3
Assembly Part No.
210003GA
210005GA
210008GA
210009GA
210011GA
210176GA
210014GA
210013GA
210016GA
210146GA
210140GA
210036GA
210038GA
210091GA
210062GA
GRADE 5 BOLT ASSEMBLIES, GALVANIZED
[HEX BOLTS, NUT & LOCKING DEVICE]
Full Thread
Pal nuts included with assembly P/N shown.
See table below for other nut locking devices.
Thread Length
= 2 (bolt dia.) + 1/4
Weight (lbs./100pcs)
7/100
10/100
10/100
12/100
13/100
13/100
18/100
18/100
17/100
35/100
38/100
51/100
53/100
91/100
103/100
Suffix
-
AN
TLN
LW
Nut Locking Device
Pal Nut
Anco Nut
Tri-Loc Nut
Split Ring Washer
NUT LOCKING DEVICE OPTIONS
[ADD SUFFIX AFTER BOLT ASSEMBLY PART NUMBER]
Example:
For 3/8 x 1-1/2 bolt assembly with a split ring lock washer
used for a nut locking device, in place of a pal nut, order
part number: 210011GALW
NOTE: To order bolts or other hardware in this catalog without nuts and nut locking devices,
remove the A from the end of the assembly part number.
Dimensions (inches) Weight
(lbs./100pcs)
73/100
87/100
91/100
119/100
277/100
U-BOLTS, SQUARE BEND, GALVANIZED
Assy. Part No.
JR811A
JR812A
JR812LA
JR815A
JR12685SQA
A
1/2
1/2
1/2
1/2
3/4
B
3-1/4
4-1/4
4-1/4
6-1/4
6-1/4
C
4-3/8
5-5/16
5-13/16
7-13/16
8-1/2
D
1-1/4
1-1/4
1-3/4
1-3/4
2-1/2
Dia. x Length (inches)
1/2 x 1-1/4
1/2 x 1-1/2
1/2 x 1-3/4
1/2 x 2
5/8 x 1-1/2
5/8 x 1-3/4
5/8 x 2
5/8 x 2-1/4
5/8 x 2-1/2
5/8 x 3-1/4
3/4 x 1-3/4
3/4 x 2
3/4 x 2-1/4
3/4 x 2-1/2
3/4 x 2-3/4
3/4 x 4-1/2
3/4 x 5
3/4 x 5-1/2
7/8 x 2-1/4
7/8 x 3-1/2
1 x 4-1/4
1 x 5-1/2
1 x 6
Weight
(lbs./100pcs)
21/100
22/100
24/100
25/100
34/100
36/100
68/100
42/100
43/100
45/100
58/100
61/100
62/100
66/100
70/100
91/100
94/100
104/100
94/100
113/100
172/100
197/100
204/100
STRUCTURAL BOLT ASSEMBLIES, 120 KSI TENSILE
STRENGTH, GALVANIZED
[HEAVY HEX BOLTS, NUTS & NUT LOCKING DEVICE]
Assy. Part No.
210017GA
210018GA
210019GA
210020GA
210029GA
210030GA
210031GA
210032GA
210033GA
210072GA
210046GA
210047GA
210048GA
210048GA
210050GA
210057GA
210058GA
210059GA
210061GA
210063GA
210069GA
210070GA
210164GA
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
H
HA R DWA R E
291
2011 ROHN PRODUCTS LLC
NUT S , B OLT S & WA S HE R S
A
B
D
C
Pal nuts included with assembly P/N shown.
Add sufx from page 288 for other nut locking device.
Pal nuts included with assembly P/N shown.
Add sufx from page 288 for other nut locking device.
Bolt Diameter
1/2
5/8
3/4
7/8
1
1-1/8
1-1/4
1-3/8
1-1/2
Thread Length (inches)
1
1.25
1.38
1.5
1.75
2
2
2.25
2.25
THREAD LENGTHS
NUT S , B OLT S & WA S HE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
292
2011 ROHN PRODUCTS LLC
H
A
B
D
C
Dimensions (inches)
U-BOLTS, ROUND BEND, GALVANIZED
Assy. Part No.
JR45GA
JR51A
JR55A
JR54A
JR69A
JR67A
JR66A
JR65A
JR68A
JR60A
JR61A
JR64A
JR62A
JR63A
JR81A
JR810A
JR82A
JR83A
JR84A
JR84SA
JR88A
JR89A
JR85A
JR86A
JR87A
JR90SA
JR110A
JR120A
JR121A
JR122A
JR123A
JR124A
JR125A
JR126STA
JR128A
JR1210A
JR1212A
A
1/4
5/16
5/16
5/16
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
B
1-1/4
1-1/2
1-1/2
1-11/6
13/16
1
1-1/4
1-1/2
2-1/8
2-1/2
2-1/2
3-1/2
4
4-1/2
3/4
2
2-1/4
2-1/2
3
3
3-1/2
4
4-1/2
5-5/8
6-3/4
8-3/4
10-7/8
12-7/8
3
3-1/2
4
4-1/2
5-5/8
6-3/4
8-3/4
10-7/8
12-3/4
C
2-1/4
2-5/8
2
2-1/4
1-5/8
2-1/4
2-3/4
3
3
4
3-1/2
4-5/8
6
6-1/2
3-1/2
3-3/4
4-1/2
4-1/2
5-5/8
4-1/8
6
6-1/2
6
8
9
11-1/8
13
15
5-3/4
6-1/4
6-3/4
7-1/4
8-5/16
10
11-3/8
13-3/8
15
D
1-3/8
1-1/4
1-1/4
1
7/8
1-1/4
1-5/8
1-3/4
1-1/4
2
1-1/2
1-5/8
2-1/4
2-1/4
2-1/2
1-3/4
2-1/4
2-1/2
3
1-1/2
3
3-1/2
2-1/4
3-1/4
3-1/4
2-1/2
2-1/2
2-1/2
3
2-3/4
2-1/2
2-1/2
2-1/2
3-1/2
2-1/2
2-5/8
2-1/2
Pal nuts included with assembly P/N shown.
Add sufx from page 288 for other nut locking device.
Weight
(lbs./100pcs)
12/100
15/100
14/100
15/100
21/100
23/100
31/100
29/100
31/100
35/100
33/100
41/100
42/100
52/100
60/100
63/100
71/100
71/100
84/100
73/100
88/100
98/100
91/100
114/100
127/100
188/100
198/100
243/100
199/100
263/100
284/100
280/100
318/100
390/100
424/100
517/100
591/100
Description
5/8 x 7 (2-1/2 THD Length)
5/8 x 7 (2-1/2 THD Length)
With 2 Heavy Hex Nuts
Weight (lbs./100pcs)
84/100
108/100
Part No.
210042G
5/8STEP
Description
1/2 x 12 + 2 (Hook)
5/8 x 12
3/4 x 16 + 3 (Hook)
Weight (lbs.)
1/2 ea.
1 ea.
1-1/2 ea.
Part No.
1/2X12BB
260145G
3/4X16BB
Description
5/16 dia. (18 THD)
For 1-1/4 Tubing
Assy. Part No.
TB5125BA
Weight (lbs./100pcs)
54/100
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
H
HA R DWA R E
293
2011 ROHN PRODUCTS LLC
NUT S , B OLT S & WA S HE R S
J -BOLTS, GALVANIZED
A
B
D
C
Dimensions (inches)
Assy. Part No.
J44AA
J51A
J170A
J167A
A
3/8
3/8
3/8
3/8
B
5/8
5/8
5/8
3/4
C
4
5-11/16
7-9/16
2
D
2-5/8
2-3/4
5-1/2
1-1/2
U-BOLTS, DOUBLE BEND, GALVANIZED
BASE BOLT, GALVANIZED
Includes base bolt
and nuts.
STEP BOLT, GALVANIZED
5/8 x 12
1/2 x 12
3/4 x 16
Pal nuts included with assembly P/N shown.
Add sufx from page 288 for other nut locking device.
Weight (lbs./100pcs)
16/100
23/100
35/100
10/100
NUT S , B OLT S & WA S HE R S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
294
2011 ROHN PRODUCTS LLC
H
HEAVY HEX NUT OPTIONS, GALVANIZED
HARDENED FLAT WASHERS, GALVANIZED
Description
3/8
1/2
5/8
3/4
7/8
1
Description
3/8 - 16
1/2 - 13
5/8 - 11
3/4 - 10
7/8 - 9
1 - 8
Anco Nut Plain Nut
Pal Nut
(used with plain nut)
Tri-Loc Nut
Plain Nut
230005
110143
110146
230020
110149
110150
Weight
(lbs./100pcs)
3/100
7/100
12/100
19/100
30/100
43/100
Weight
(lbs./100pcs)
0.4/100
1/100
1/100
2/100
2/100
4/100
Pal Nut P/N
110159
110160
110161
110162
110163
110164
Weight
(lbs./100pcs)
3/100
7/100
12/100
19/100
30/100
43/100
Tri-Loc P/N
38CTLFG/2H
50CTLFG/2H
58CTLFG/2H
75CTLFG/2H
78CTLFG/2H
1CTLFG/2H
Weight
(lbs./100pcs)
3/100
7/100
12/100
19/100
30/100
43/100
Anco P/N
230008
110581
110510
110511
110512
110513
Plain Washer
Split Ring Washer
Weight
(lbs./100pcs)
1/100
2/100
3/100
5/100
6/100
8/100
Plain Washer
110950
110202
110205
110208
110210
110214
Weight
(lbs./100pcs)
1/100
2/100
3/100
5/100
10/100
10/100
Split Ring Washer
250082
250083
250084
250042
250046
250047
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
H
HA R DWA R E
295
2011 ROHN PRODUCTS LLC
NUT S , B OLT S & WA S HE R S
BEVELED WASHERS, GALVANIZED
Description
3/8
1/2
5/8
3/4
7/8
1
Part No.
110398
110399
110400
110551
250062G
110686
Description
1/4 Standard thimble,
open for 1/8 to 3/16 guys
5/16 Heavy duty thimble,
open for 3/16 guys
3/8 Heavy duty thimble,
open for 1/4 guys
7/16 Heavy duty thimble,
open for 5/16 guys
1/2 Heavy duty thimble,
open for 3/8 guys
9/16 Heavy duty thimble,
open for 7/16 guys
5/8 Heavy duty thimble,
open for 1/2 or 9/16 guys
3/4 Heavy duty thimble,
open for 5/8 guys
7/8 Heavy duty thimble,
open for 3/4 guys
1 Heavy duty thimble,
open for 7/8 guys
THIMBLES, GALVANIZED
Assy. Part No.
1/4TH
5/16THH
3/8THH
7/16THH
1/2THH
9/16THH
5/8THH
3/4THH
7/8THH
1THH
R OHN GUY MAT E R I A L S
Weight (lbs./100pcs.)
7/100
7/100
15/100
14/100
31/100
28/100
Weight (lbs./100pcs.)
4/100
12/100
25/100
30/100
51/100
51/100
75/100
147/100
175/100
275/100
R OHN GUY MAT E R I A L S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
296
2011 ROHN PRODUCTS LLC
H
CABLE CLAMPS, FORGED, GALVANIZED
Description
3/16 Cable Clamp, Forged
1/4 Cable Clamp, Forged
5/16 Cable Clamp, Forged
3/8 Cable Clamp, Forged
Part No.
140214
140001
140002
140003
NUT & PIN TYPE SHACKLES, HEAT TREATED,
GALVANIZED
Description
3/8 (13,200 lbs. ultimate strength)
1/2 (26,400 lbs. ultimate strength)
5/8 (42,000 lbs. ultimate strength)
3/4 (67,700 lbs. ultimate strength)
7/8 (85,800 lbs. ultimate strength)
1 (112,200 lbs. ultimate strength)
1-1/8 (125,400 lbs. ultimate strength)
1-1/4 (158,400 lbs. ultimate strength)
Part No.
3/8S
1/2S
5/8S
3/4S
7/8S
1S
1-1/8S
1-1/4S
BIG GRIP END SLEEVES, GALVANIZED
Description
3/16
1/4
5/16
3/8
7/16
1/2
9/16
5/8
3/4
7/8
1
Part No.
GC65303
GC65136
GG65128
GC65264
GC65265
GC65266
GC65267
GC65268
GC65269
GC65270
GC65271
NOTES:
1. Oversized heavy duty thimbles must be used with all Big-Grips.
Weight (lbs./100pcs.)
10/100
20/100
30/100
47/100
Weight (lbs./100pcs.)
25/100
70/100
150/100
232/100
340/100
500/100
700/100
975/100
Weight (lbs./100pcs.)
3/100
3/100
3/100
5/100
7/100
10/100
11/100
14/100
21/100
27/100
32/100
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
H
HA R DWA R E
297
2011 ROHN PRODUCTS LLC
R OHN GUY MAT E R I A L S
TURNBUCKLES, HEAT-TREATED, GALVANIZED
Thread Diameter x Take Up
3/8 x 6 (6,000 lbs. ultimate strength)
3/8 x 6 (6,000 lbs. ultimate strength)
1/2 x 12 (11,000 lbs. ultimate strength)
1/2 x 12 (11,000 lbs. ultimate strength)
5/8 x 12 (17,500 lbs. ultimate strength)
3/4 x 12 (26,000 lbs. ultimate strength)
7/8 x 12 (36,000 lbs. ultimate strength)
1 x 12 (50,000 lbs. ultimate strength)
1-1/4 x 18 (76,000 lbs. ultimate strength)
1-1/2 x 18 (107,000 lbs. ultimate strength)
1-3/4 x 18 (140,000 lbs. ultimate strength)
Part No.
3/8TBE&E
3/8TBE&J
1/2TBE&E
1/2TBE&J
5/8TBE&J
3/4TBE&J
7/8TBE&J
1TBE&J
11/4X18TB
11/2X18TB
13/4X18TB
Description
3/16
1/4
5/16
3/8
7/16
1/2
9/16
5/8
3/4
7/8
Part No.
BG2142
BG2144
BG2146
BG2147
BG2148
BG2115
BG2116
BG2111
BG2112
BGMS7023
BIG-GRIPS, GALVANIZED
[BIG-GRIP WITH END SLEEVE]
EYE BOLT, GALVANIZED
Description
5/8 x 18 Eye Bolt with Nuts
Part No.
260004P
SCREW ANCHOR, GALVANIZED
Description
1/2 dia. x 30 long (4 auger)
5/8 dia. x 48 long (6 auger)
Part No.
GAS4303
GAS604
Weight (lbs./100pcs.)
33/100
50/100
82/100
112/100
188/100
315/100
480/100
650/100
1080/100
1125/100
Weights (lbs.)
1
1
2
2
4
5
8
11
24
35
54
Weight (lbs.)
2
Weight (lbs.)
7
7
Type
EE
EJ
EE
EJ
EJ
EJ
EJ
EJ
EJ
EJ
EJ
Eye & Jaw (EJ)
Eye & Eye (EE)
R OHN GUY MAT E R I A L S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
298
2011 ROHN PRODUCTS LLC
H
GUYS, GALVANIZED
Description
6 Strand, 18GA - 1,000coil (610 lbs.ultimate strength)
3/16 - 500 coil (3,990 lbs. ultimate strength)
3/16 - 1,000 coil (3,990 lbs. ultimate strength)
3/16 - cut length* (3,990 lbs. ultimate strength)
1/4 - 500 coil (6,650 lbs. ultimate strength)
1/4 - 1,000 coil (6,650 lbs. ultimate strength)
1/4 - cut length* (6,650 lbs. ultimate strength)
5/16 - cut length* (11,200 lbs. ultimate strength)
3/8 - cut length* (15,400 lbs. ultimate strength)
7/16 - cut length* (20,800 lbs. ultimate strength)
1/2 - cut length* (26,900 lbs. ultimate strength)
9/16 - cut length* (35,000 lbs. ultimate strength)
5/8 - cut length* (42,400 lbs. ultimate strength)
3/4 - cut length* ( 58,300 lbs. ultimate strength)
7/8 - cut length* (79,700 lbs. ultimate strength)
1 - cut length* (122,000 lbs. ultimate strength)
Part No.
618
3/16EHS500
3/16EHS1000
3/16EHS
1/4EHS500
1/4EHS1000
1/4EHS
142265
142261
142260
142259
142258
142264
142257
142256
1BS
GUY STRAIN INSULATORS, PORCELAIN
Description
10,000 lbs. ultimate strength
12,000 lbs. ultimate strength
20,000 lbs. ultimate strength
Part No.
502
504
506
Weight (lbs.)
42
36
73
73/MFT
60
120
120/MFT
205/MFT
279/MFT
399/MFT
517/MFT
671/MFT
813/MFT
1155/MFT
1581/MFT
2100/MFT
Weight (lbs.)
1
1.5
3
*Please provide desired guy length with order.
MFT = 1,000 FT
GRIPPLE GRIP
Description
Gripple Grip for 6 strand, 18 GA guy installation
Part No.
61820GRPL
R OHN R E V G GR OUNDI NG
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
H
HA R DWA R E
299
2011 ROHN PRODUCTS LLC
Tower Leg
Tower Base
Tower Leg
Ground Rod
Ground Rod
Ground Rod
(2) provided
Ground Rod
Clamp
Ground Rod
Clamp
Ground Rod
Clamp
Ground Lead
Round member
ground clamp
Top of
Ground Rod
6" Min. below
ground
Top of
Ground Rod
6" Min. below
ground Top of
Ground Rod
6" Min. below
ground
Ground lug
GroundWire
Attachment Lug
G-Series tower bases
Tower/Pole bases with anchor bolts
GUY ANCHOR GROUNDING KIT
No. 80 & 90 tower bases
Description
80 & 90 Tower Base Grounding Kit
55G & 65G Base Grounding Kit
25G & 45G Base Grounding Kit
Guy Anchor Grounding Kit
Guy Anchor Clamp for 1/2 - 3/4 O.D. Rods
Guy Anchor Clamp for 1 - 1-1/4 O.D. Rods
Guy Anchor Clamp for 1-1/2 - 2 O.D. Rods
Guy Anchor Clamp for Angle Anchor Rods
1/2 Anchor Bolt Grounding Kit
5/8 Anchor Bolt Grounding Kit
3/4 Anchor Bolt Grounding Kit
7/8 Anchor Bolt Grounding Kit
1 Anchor Bolt Grounding Kit
Kit Part No.
BGK1GGX
BGK2GGX
BGK3GGX
AGK1GGX
CPC.5/.75
CPC1/1.25
CPC1.5/2
213
BGK4GGX
BGK5GGX
BGK6GGX
BGK7GGX
BGK8GGX
Ground Wire
Ground Rod Clamp
Ground Rod
Clamp ordered separately
from guy anchor grounding
kit based on anchor rod size
and type. See chart below.
Ground Lead
Ground Lead
6 Min.
Anchor Rod
Tower Type
Guyed Masts
Self-Supporting
Structures
No. of Kits Required
3 per tower
3 per tower
3 per tower
1 per each anchor radius
1 per anchor
1 per anchor
1 per anchor
1 per anchor
3 per tower/pole
3 per tower/pole
3 per tower/pole
3 per tower/pole
3 per tower/pole
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
300
2011 ROHN PRODUCTS LLC
H
S T E E L T UB I NG
ROHN ofers both swaged and expanded 16 GA. tubing, commonly used with our roof and wall
mounts.
Swaged - This tubing has a locking joint. When tubing is swaged, the metal is compressed
and made thicker so that the joint is stronger than the original material. Swaging also
eliminates the joint bulge common with expanded tubing.
Expanded - A tube with an expanded end used along with a tube with a plain end.
ROHN tubing is ofered in two types of fnishes, hot-dip galvanized and pre-galvanized.
ROHNs hot-dip galvanized tubing is fabricated from high strength steel, then immersed in
molten zinc giving all surfaces, including the interior, an even coating of zinc for maximum
corrosion protection. There are no seams, holes or edges left uncoated. Pre-galvanized
tubing is made from a coil of steel which is galvanized at the steel mill, cut into strips, and
then formed into a piece of tubing. Where the tubing is welded, zinc is sprayed over the
weld to give it protection. It has a slightly uncoated seam on the inside and ends.
Tubing Part No.
160505GHS
160505PHS
160506PLX
161005GHS
161005PHS
Description
1-1/4 O.D. x 16 GA. x 5 long
1-1/4 O.D. x 16 GA. x 5 long
1-1/2 O.D. x 16 GA. x 5 long
1-1/4 O.D. x 16 GA. x 10 long
1-1/4 O.D. x 16 GA. x 10 long
TUBING SPECIFICATIONS
End Type
Swaged
Swaged
Expanded
Swaged
Swaged
Finish
Hot-Dip Galvanized
Pre-Galvanized
Pre-Galvanized
Hot-Dip Galvanized
Pre-Galvanized
Expanded Swaged
Locking Joint - Swaged Ends
MOUNT I NG T UB E S
H OT - D I P G A LVA N I Z E D
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
H
HA R DWA R E
301
2011 ROHN PRODUCTS LLC
Description
Part
Length
Number
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.38 O.D. x 0.154 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
2.88 O.D. x 0.203 wall
4.50 O.D. x 0.237 wall
4.50 O.D. x 0.237 wall
4.50 O.D. x 0.237 wall
4.50 O.D. x 0.237 wall
4.50 O.D. x 0.237 wall
4.50 O.D. x 0.237 wall
5' KH275
6' KH1256
8' KY1304
10' KH287
12'
14'
KH365
16 KH2806
18
KH2805
5' KH276
6' KH2576
8' KH2541
10' KH288
12' KH366
14' KH2802
16' KH2803
18' KH2804
20 KH4813
5' KH279
8' KH2447
10' KH291
12' KH369
14' KH2509
5' KH1193
6' - 8 KH1194
8' KH2229
5' KH1200
8' KH2987
10' KH1202
12' KH1203
14' KH5768
5' KH1221
8' KH1977
10' KH1223
12' KH1224
16' KH3614
18' KH5627
Description
Part
Length
Number
KH2807
2.38 O.D. x 0.218 wall
2.38 O.D. x 0.218 wall
2.38 O.D. x 0.218 wall
2.88 O.D. x 0.276 wall
2.88 O.D. x 0.276 wall
2.88 O.D. x 0.276 wall
2.88 O.D. x 0.276 wall
2.88 O.D. x 0.276 wall
2.88 O.D. x 0.276 wall
4.50 O.D. x 0.337 wall
4.50 O.D. x 0.337 wall
4.50 O.D. x 0.337 wall
4.50 O.D. x 0.337 wall
4.50 O.D. x 0.337 wall
4.50 O.D. x 0.337 wall
4.50 O.D. x 0.337 wall
27
36
43
41
55
65
82
98
114
80
106
127
159
191
254
286
Weight
(lbs.)
20
24
26
30
39
47
55
62
70
31
37
41
50
62
74
86
99
111
123
58
77
92
115
138
161
Weight
(lbs.)
6' 8 KH281
6' 8 KH282
6' 8 KH285
6' - 8 KH1222
6' - 8 KH1201
Standard Extra Heavy
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
HA R DWA R E
302
2011 ROHN PRODUCTS LLC
H
PAINT
Description Part No.
PNTNPO5
PNTNPW9
Tower Paint, Orange, Acrylic Latex
Tower Paint, White, Acrylic Latex
COLD GALVANIZE
Description
Cold Galvanize, Spray
Cold Galvanize, Gallon
Part No.
380063
380147
Weight (lbs.)
11/gal.
11/gal.
Weight (lbs.)
1/can
1/gal.
MI S C E L L A NE OUS
FA A S T Y L E A S E R I E S
R E D OB S T R U C T I ON
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R L I GHT I NG GUI DE L I NE S
304
2011 ROHN PRODUCTS LLC
L
0 - 150
[0m - 46m]
151 - 350
[46m - 107m]
351 - 700
[108m - 213m]
701 - 1050
[213m - 320m]
1051 - 1400
[320m - 427m]
1401 - 1750
[427m - 533m]
1751 - 2200
[535m - 671m]
L-864 (Red Beacon)
L-810 (Obstruction Light)
A-0 A-1 A-2 A-3 A-4 A-5 A-6
Day Protection = Aviation Orange/White Paint
Night Protection = 2,000cd Red Beacon and Sidelights
1/2 of tower height
but not lower than
200 (61m)
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
L
T OWE R L I GHT I NG GUI DE L I NE S
305
2011 ROHN PRODUCTS LLC
FA A S T Y L E B S E R I E S
H I G H I N T E N S I T Y
501 - 700
[152m - 213m]
701 - 1050
[213m - 320m]
1401 - 1750
[427m - 533m]
1051 - 1400
[320m - 427m]
1751 - 2200
[533m - 671m]
B-2 B-3 B-4 B-5 B-6
L-856 (High Intensity Strobe
3 Flashheads required per
level for 360 coverage
Day Protection = 200,000cd White Strobe
Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd White Strobe
o
FA A S T Y L E C S E R I E S
H I G H I N T E N S I T Y
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R L I GHT I NG GUI DE L I NE S
306
2011 ROHN PRODUCTS LLC
L
501 - 700
[152m - 213m]
701 - 1050
[213m - 320m]
1051 - 1400
[320m - 427m]
1401 - 1750
[427m - 533m]
1751 - 2200
[533m - 671m]
L-865 (Medium Intensity Strobe)
Required for appurtenances of 40
or greater
C-2 C-3 C-4 C-5 C-6
L-856 (High Intensity Strobe)
3 Flashheads required per level
for 360 coverage
Day Protection = 200,000cd White Strobe
Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd White Strobe
o
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
L
T OWE R L I GHT I NG GUI DE L I NE S
307
2011 ROHN PRODUCTS LLC
FA A S T Y L E D S E R I E S
ME D I U M I N T E N S I T Y WH I T E
200 - 350
[61m - 107m]
351 - 500
[107m - 152m]
200 - 350
[61m - 106m]
351 - 500
[106m - 152m]
D-1 D-2
E-1 E-2
L-865 (Medium Intensity Strobe)
L-864/L-865 (Dual Red/White
Medium Intensity Strobe)
L-810 (Obstruction Light)
FA A S T Y L E E S E R I E S
ME D I U M I N T E N S I T Y D UA L
Day/Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd White Strobe
Day/Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd Red Strobe & Sidelights
1/2 of tower height
but not lower than
200 [61m]
1/2 of tower height
but not lower than
200 [61m]
FA A S T Y L E F S E R I E S
D UA L H I G H I N T E N S I T Y
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
T OWE R L I GHT I NG GUI DE L I NE S
308
2011 ROHN PRODUCTS LLC
L
501 - 700
[152m - 213m]
701 - 1050
[213m - 320m]
1051 - 1400
[320m - 427m]
1401 - 1750
[427m - 533m]
1751 - 2200
[533m - 671m]
F-2 F-3 F-4 F-5 F-6
L-864 (Red Beacon)
L-810 (Obstruction Light)
Day Protection = 200,000cd White Strobe
Twilight Protection = 20,000cd White Strobe
Night Protection = 2,000cd Red Beacon and Sidelights
o
L-856 (High Intensity Strobe)
3 Flashheads required per level
for 360 coverage
R OHN CONS T R UC T I ON S E R V I C E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
CONS T R UC T I ON MA NAGE ME NT
310
2011 ROHN PRODUCTS LLC
I
ROHNs Construction Group has direct and immediate access to company management, engineering, production and
shipment to provide you with the highest quality products and a wide range of services to help you complete your project.
This direct and simple line of communication saves time and eliminates long distance contact between the manufacturer
and installer. It enables us to answer questions internally before they have the chance to grow into costly delays.
We employ professionals with the expertise required to provide you a full turnkey communication project. We understand
your needs, and when your job becomes a ROHN Construction project, we assign a single staf member to take charge.
This one point of contact provides you the answers from scope changes to shipping schedules. At any time, you can be
assured of the updated status of all phases of your project without having to contact multiple manufacturers and
contractors.
ROHNs Construction Group, in addition to our in-house staf, has a network of suppliers, consultants and contractors
to provide:
Certied Tower Design Drawings
Zoning and Permitting Assistance
Environmental Studies
Geotechnical Services
Site Preparation
Civil Construction
Tower Foundations
Equipment Shelter Foundations
Tower Erection
Equipment Shelter Installation
Provide and Install Antennas and Transmission Lines
System Testing
Security Fencing
Maintenance and Inspection
With over 60 years experience, what company could be more qualied to provide single source turnkey installation
services more quickly and efciently than ROHN? Nobody knows the products and installation methods the way ROHN
does. Rest assured, ROHN is there to fulll all your requirements.
CONS I DE R AT I ONS I N E R E C T I NG
T OWE R S & S I MI L A R P R ODUC T S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
CONS I DE R AT I ONS I N E R E C T I NG T OWE R S
312
2011 ROHN PRODUCTS LLC
I
Your local municipality or development may have established height and building standards governing the use of towers and similar
products. Height restrictions are found in zoning ordinances and private deed restrictions. Building standards may be found in local
building codes. Complying with these requirements is usually easy and will help to provide many years of safe and trouble free operation
of your installation.
Zoning ordinances, building codes and private deed restrictions are complex legal documents. If you question whether they apply to
you, consult a local attorney. Five minutes spent in advance may save hours later.
Zoning ordinances, building codes and deed restrictions are local. If you move from city to city, these restrictions may change.
Zoning ordinances are concerned with the type of buildings or other structures you can erect in your neighborhood. In terms of towers
and similar products, zoning laws will tell you if your property is zoned for such items, and if so, what height limitations, if any are involved.
Building codes are concerned with the safety of buildings or other structures permitted by local zoning ordinances. Building codes will
tell you where on your property you can put the installation and the type of loading you will need to consider.
Both zoning and building codes are usually administered by the same governmental agency, often known as the Department of
Building and Safety or the Zoning Board.
The following steps will help make sure you have a safe, legal installation.
1. Check with the local governmental agency. Ask whether your home is zoned for the type of product you wish to install.
2. Look at the actual zoning ordinances. Pay special attention to the definitions. Many zoning ordinances distinguish between buildings
and structures. Others distinguish between towers physically attached to the house, either by guy wires or mounting and towers that
are not attached.
3. See if a building permit is required. If so, be sure to get one. They are usually quite inexpensive, often less than one percent of the cost of
the tower. As part of the building permit, a local inspector will check and make sure that the base, guy wires, etc. meet local safety
requirements. Properly manufactured commercially made towers are extremely safe and have a large safety margin, but only if you
install them according to the directions! If a permit is required and not obtained, your home-owners insurance may not insure the
tower and you have given neighbors, who might object, a reason to require you to take the tower down.
4. In a limited number of cases, you may need either a zoning variance or a conditional use permit to erect a structure higher than the
local zoning board requirements. If so, it is far easier to apply in advance than to put up the structure and apply later. Most local
governments are quite cooperative if you apply in advance and follow their rules. Variance provisions are used to provide flexibility
from dimensional regulations such as setback or height restrictions. Conditional use permits are used where towers or antennas are
not otherwise allowed. A public hearing is usually required before such permits are issued.
5. In addition to local ordinances, real estate developers or homeowners associations may impose their own requirements in a
subdivision. These requirements are usually known as deed restrictions or Conditions, Covenants and Restrictions (CC&R).
If you are thinking of moving into a new area, ask for a copy of the deed restrictions in advance of signing an offer to purchase the
property. If you already own a home, a local realtor, title insurance company or lawyer can obtain copies of the deed restrictions, if any,
for you. Dont take the word of the realtor who may be wrong.
If there are no deed restrictions, you need only be concerned with local zoning and building codes. If there are deed restrictions, read
them carefully. Look at the definitions. See if there are any restrictions on outside structures or if a local architectural control committee
must pass on any additions or changes to your property.
Deed restrictions are legal documents. A local lawyer familiar with real estate law can read the restrictions in only a few minutes and advise
you. Even if the deed restrictions prohibit or restrict the size of towers and similar products, they may be unenforceable if many of your
neighbors have erected such products and no objections have been raised.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
COMMUNI C AT I ON T OWE R S P E C I F I C AT I ONS
313
2011 ROHN PRODUCTS LLC
R E COMME NDAT I ONS F OR S P E C I F Y I NG
COMMUNI C AT I ON S T R UC T UR E S
The basic standard for the design of steel antenna supporting structures is ANSI/TIA-222-G. Prior to issuing a specification, the specifying
authority must have a working familiarity with this standard and its requirements. The following information is presented as the basis for
preparing a tower specification.
Location: The tower is to be installed at _________________________________________ (include site name, state and county).
Tower Requirements: The structure is to be guyed/self-support/pole (circle one) with a normal overall structural height of
_________ feet. The tower is to be designed for a _________ mph wind speed as defined by ANSI/TIA-222-G.
Ice loading shall be considered at _________ inches per ANSI/TIA-222-G and ___________ mph wind speed.
The tower shall be designed to accommodate the following antenna loads: (At this point, please list all antennas, their mounting elevations,
and transmission line requirements, providing as specific detail as possible. This should include microwave antenna azimuths, if known, and
frequencies.)
Owner shall define structure class, exposure and topographic category (see pages 14-16).
The structure should be oriented on the property with one leg at _________ degrees, true north. Provide orientation if there is a specific
orientation required due to property restrictions or desired by the purchaser. (Does not apply to poles).
The following appurtenances shall be incorporated into design as required by ANSI/TIA-222-G. (Note which appurtenances are to be
provided with the structure.)
1. Climbing Ladder
2. Safety Device
3. Rest/Working Platforms
4. Transmission Line Support Ladders/Brackets
5. Obstruction Warning Lights and/or Paint
6. Antenna Mounts
7. Ice Shields
8. Grounding Materials
9. Waveguide Bridge
10. Port Size / Location for Poles
ROHN recommends the following requirements be included in specifications for the benefit of the purchaser:
The vendor shall be a manufacturer, primarily and continuously involved in the design and production of communication towers for
at least ten years.
In order to specifically define responsibilities, the vendor shall maintain in-house control over the design and fabricating functions.
Subcontracting of these responsibilities will be cause for rejection of a vendors proposal.
Each structural member shall be identified by a part number and all parts with the same part number must be interchangeable. This will
result in tower sections capable of being installed in any 120 degree rotation. Match marking requirements of tower sections by the
manufacturer, for proper assembly, shall not be acceptable.
Tower leg members shall utilize a 50 KSI minimum yield strength. Tubular leg members with flange splices shall maintain an open interior
diameter through the flange plate at least as large as the inside diameter of the tube and shall be welded externally and internally.
Flange leg connections shall utilize a minimum of four bolts per leg.
All fabricated tower members shall be hot-dip galvanized after fabrication per ASTM Standard A123. Hardware shall be galvanized per
ASTM Standard A153 and B695. Other types of coatings are not acceptable.
Four sets of tower assembly drawings illustrating all component part numbers and their respective locations shall be provided. As a
minimum, assembly drawing shall be accompanied by a letter sealed by a registered professional engineer licensed in the state in which
construction is to be performed, certifying that the tower meets all design requirements per ANSI/TIA-222-G.
The tower manufacturer shall be an AISC Certified Fabricator and shall maintain the highest quality steel manufacturing standards for
production. Only AWS Certified Welders shall be employed for tower fabrication. A fully qualified quality control department shall be
employed with a quality control manual maintained to establish minimum acceptable fabrication standards, procedures and requirements
for documentation.
With the use of ANSI/TIA-222-G and the procurement and user guidelines (Annex A), accompanied by the commentary noted above, a
thorough specification can be developed.
Copyright 2011 by ROHN Products, LLC. All rights reserved.
GUI DE L I NE S F OR T HE P R E PA R AT I ON
OF A GE OT E C HNI C A L R E P OR T
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
GE OT E C HNI C A L R E P OR T GUI DE L I NE S
314
2011 ROHN PRODUCTS LLC
I
I. PURPOSE AND INTENT

a) The intended purpose of these guidelines is to assist the customer and/or owner to retain the services of a
Geotechnical Engineer.

b) It is not ROHNs purpose or intent to supercede the Geotechnical Engineers knowledge, judgement and/or experience.
It is the Geotechnical Engineers responsibility to add or delete from these items, based on local site conditions and
other factors.
c) Additional information is provided in ANSI/TIA-222-G Annex G Geotechnical Investigations.
II. DISCLAIMER
a) ROHN will not accept any liability, either expressed or implied, for the use of, and omissions in, these guidelines.

III. EXPLORATORY BORINGS
a) Borings should be taken at tower legs for self-supporting towers and at the base and anchor points for guyed towers.
For small self-supporting towers, two borings may suffice. For large self-supporting towers, one boring should be taken
at each tower leg. A small self-supporting tower is assumed to have a face width less than 20 feet and a compression
load less than 50 kips per leg. For pole structures, one boring may suffice.
b) The minimum boring depth should be 30 feet for pole structures, self-supporting towers and guyed tower bases. For
guyed tower anchors, the minimum depth should be 15 feet. The actual depth of boring must be determined by the
Geotechnical Engineer based on reactions, soil conditions and the type of foundation recommended.
c) If borings cannot be advanced to the desired depth, rock corings should be taken. Rock Quality Designation (RQD)
values and compressive strengths should be determined.
IV. GEOTECHNICAL REPORT
a) The following properties, for each soil layer encountered, should be determined by field or laboratory testing and
summarized in the geotechnical report:
1. Soil classification and elevations
2. Standard penetration values
3. Unconfined compression strength
4. Angle of internal friction
5. Cohesion
6. In-Situ soil density and moisture content
7. Rock quality designation (RQD) and percent rock sample recovered
8. Other properties unique to site conditions
b) The following items should be discussed in the geotechnical report:
1. Geological description of site
2. Observed and expected ground water conditions
3. Expected frost penetration depth
4. Corrosion potential of soil and corrosion protection recommendations
5. Site access and potential construction difficulties
6. Dewatering or site drainage requirements
7. Backfill material recommendations
8. Settlement considerations
9. Additional information to aid foundation designer
10. Recommended types of foundations
11. Design parameters for uplift, download and lateral load
12. Factor of safety considered when allowable vs. ultimate design parameters are provided
13. Recommended construction techniques and inspections
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
S A F E T Y I NF OR MAT I ON
315
2011 ROHN PRODUCTS LLC
This information may save you from death or injury. Do not attempt to install or dismantle any ROHN products until you have read and
understood the information in this document.
Do not attempt to install or dismantle ROHN products near any type of power line. Should your installation come into contact with power
lines, you can be killed! Be sure your installation is out of falling distance of any overhead wires including the lead to any building. Read
all instructions carefully before you begin, or better yet, call a professional it may save your life.
ROHNs ACWS sign must be attached to all poles, towers, guyed mast bases in a location which is conspicuous
and readable from the ground so that all personnel are notified and warned. Aluminum wire is furnished for
attaching signs. ROHN recommends you check frequently to make sure the sign has not been removed.
These 6" x 9" signs may be ordered, specify part number ACWS.
Tower Erectors Please see that these signs are attached per the instructions above before leaving the site.
Guyed and bracketed towers are not self-supporting at any height. When installing or dismantling a guyed tower always consult your local
tower installer. The condition of a used tower is difficult to determine and in the process of dismantling you could be killed or injured.
Dismantling and installation may require the use of temporary steel guys.
General Information & Precautions
ROHN field technicians, warning labels, catalogs, guy charts, etc. are available from ROHN. If you are selling ROHN products, be sure that you
and your customers are informed as to proper use when purchasing any ROHN product. All towers, masts and poles should be installed or
dismantled by experienced and trained personnel.
Mixing of Products
The mixing of so-called interchangeable copies of ROHN products with ROHN products is dangerous and voids all engineering or warranty
data supplied by ROHN. Materials used by the so-called copies are not the same quality and have not been tested or engineered by ROHN.
Who should install or Dismantle ROHN Products?
Installing, dismantling and rigging ROHN products requires specialized skills and experience. Information supplied by ROHN assumes that
all products will be installed or dismantled by personnel having these skills and having worked with similar products before. No one should
attempt to install or dismantle ROHN products without these skills and experience. ROHN assumes no liability if faulty or dangerous practices
are used. There are available trained and experienced personnel to assist in installation, maintenance, and disassembly. Contact your local
installer if consultation or assistance is required.
What about used material?
ROHN does not recommend or warrant in any way the use of used materials. The use of used materials voids all warranties set forth by
ROHN because no one knows if the used material has been misused, overloaded, or damaged. If, for some reason, materials are re-used,
all new, galvanized, high strength bolt assemblies must be used.
General Precautions
Anti-climb sections are available on all structures to prevent unauthorized persons from climbing. Installation and dismantling may
require the use of temporary steel guys. All installations must be grounded per local and national codes. All types of installations must be
thoroughly inspected by qualified personnel and re-marked with hazard and warning labels at least twice a year to ensure safety and proper
performance. ROHN makes available many items, which may or may not be required for your particular installation. Some items available in
various types and sizes are: safety climbing devices, ladders, safety cages, anti-climb devices, work platforms, F.A.A. painting and lighting,
grounding, and fencing. Special product services and special packaging are also available. Based on local, state, or federal laws and building
codes for your area, it may be necessary for your particular installation to have special items or be given special consideration. If there are any
special requirements for your particular installation, be sure to include them in your request for quotation and on your order form. ROHN
cannot be responsible for any omission at any time.
S A F E T Y I NF OR MAT I ON
S A F E T Y I NF OR MAT I ON
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
S A F E T Y I NF OR MAT I ON
316
2011 ROHN PRODUCTS LLC
I
About OSHA
In accordance with the Occupational Safety and Health Act regulations, parts are available incorporating features, which will permit a safe
product. It is a policy of ROHN Products to design and make our products safe to use without hazards to people and/or property. We ask
that you list specific requirements you wish us to comply with in accordance with the intended use of a product. These requirements may
or may not affect the price of the materials and equipment under consideration for purchase. We would be happy to answer any additional
questions you may have.
About Step Bolts
Structures may or may not include step bolts. Step bolts are supplied as a convenience during construction. Step bolts are intended to be
climbed by professional Competent Climbers only. 100% Fall protection is required at all times. Climber safety devices are required on all
structures 10 ft. or greater in height. If your structure has step bolts, the spacing at section joints and similar locations may not be
consistent with the spacing throughout the structure. Flange plates, guys, attachments to legs, appurtenances, etc. may be an obstruction
to continuous climbing. Climbing step bolts is dangerous and can cause serious injury or death. Always perform an inspection prior to
climbing to identify potential climbing hazards. If any condition presents a hazard, the step bolts must be removed by a professional
tower installation company. ROHN will not be responsible for the use of step bolts. If you wish to use step bolts, the responsibility for
their use will be totally yours or your customers.
Installation & Dismantling Safety Instructions
Each year people are killed, mutilated, or receive severe permanent injuries when attempting to install or dismantle towers, poles, and
other structures. In many of these cases, the victim was aware of the dangers of electrocution but did not take adequate steps to avoid
the hazard. Good practice is to install your products away from power lines and obstructions. Your dealer carries a complete line of
installation and grounding hardware. For your safety and to help you achieve a safe installation, please read and follow the safety
precautions below. They may save your life! Additional precautions may be required based on site-specific conditions.

1. If you are not experienced in installing or dismantling, please, for your own safety as well as others, seek professional
assistance. Consult your dealer.
2. Select your installation site with safety, as well as performance, in mind. REMEMBER: Power lines and phone lines
look alike. For your safety, assume that any overhead lines can kill you.
3. Call your power company. Tell them your plans and ask them to look at your site. This is little inconvenience,
considering your life is at stake.
4. Before you begin, plan your installation or dismantling procedure carefully. Successful installation or dismantling is
largely a matter of coordination. Each person should be assigned to a specific task and should know what to do and
when to do it. One person should be designated as the boss to call out instructions and watch for signs of trouble.
5. When installing or dismantling, REMEMBER: Do not use a metal ladder. Do not work on a wet or windy day or if a
thunderstorm is approaching. Do dress properly shoes with rubber soles and heels, rubber gloves, long sleeve shirt
or jacket, and a hard hat and safety glasses.
6. If the assembly starts to drop, get away from it and let it fall. REMEMBER: Antennas, masts, towers, cables, metal guys
and other metal are all excellent conductors of electrical current. Even the slightest touch of any of these parts
to a power line completes an electrical path through the installer!
7. If any part of the assembly should contact a power line Dont touch it or try to remove it yourself. Call your local
power company. They will remove it safely.
8. If an electrical accident should occur dont grab hold of the person in contact with the power line or you too may be
electrocuted. Use a dry board, stick or rope to push or pull the victim away. Have someone call for medical help.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I
T E R MS & CONDI T I ONS
317
2011 ROHN PRODUCTS LLC
1. All quotation, proposals, prices, or other terms are made for acceptance within 30
days (after 30 days, prices in effect at time of shipment will apply) and shipment within
30 days of purchase order date, unless otherwise stated. They are subject to change
without notice; however, ROHN invites your request for an extension. They are also
subject to Credit and Marketing Department approval prior to acceptance. No other price
protection is available.
2. Every effort will be made to maintain shipping schedules, either on ROHN equipment
or via common carrier. ROHN cannot be responsible for delays in shipping caused by
state or local agencies with regard to permits, routing, weather, detours, etc. All
deliveries and schedules are contingent on availability of raw materials, fuel, and
transportation. ROHN will not be liable for damages on account of any delays or
abnormalities caused in shipping due to causes beyond our reasonable control. ROHN
reserves the right to make partial shipments and to submit invoices accordingly.
3. Changes or modifications to orders can be made only by written agreement executed
by all parties affected thereby, which agreement shall include any price modification.
4. ROHN's responsibility ceases upon delivery of all shipments to the carrier. The
unloading of all shipments is the responsibility of the Buyer, not the carrier or ROHN.
Buyer is warned against receipting for merchandises until careful inspection has been
made. Any claim made against ROHN must be made within 90 days after receipt of
merchandise. All merchandise leaving ROHNs factory has been carefully inspected and
ROHN does not assume responsibility for damages or shortages which occur in transit.
Buyer must make all claims and report all damages and losses to the delivering
transportation company.
5. No federal, state, or local taxes are included in quoted prices. All quotations,
proposals, prices, or other terms are subject to increase without notification by the
amount of any sales, excise, or other tax levied or charged to seller by any governmental
agency and any such tax will be passed onto purchaser as a tax or as an addition to the
selling price. This also applies to all costs incurred due to local statutes or governmental
regulations.
6. Orders are not subject to cancellation by Buyer except by written agreement with
seller. Any order canceled, after any work has been done by ROHN, such as drawings,
production, etc., will have a cancellation charge, to be determined solely at the discretion
of ROHN for whatever work has been performed with a minimum of 25% of the purchase
order price. If Buyer so chooses, he shall have the right to receive the material already
performed at time of cancellation at the quoted price. If an order is canceled before any
work has been done by ROHN, a $200 cancellation charge will apply.
7. Material received may not be returned by Buyer except by written agreement with
seller. In all cases, permission must be secured from ROHN prior to the returning of any
goods for credit. All returned goods are subject to a minimum service charge of 25%,
plus all transportation charges, and are subject to inspection by ROHN. Returned goods
will be offered and paid for only upon proof of purchase (i.e. invoice no.) and credit will
be issued against invoice value. ROHN reserves the sole right to determine amount of
credit to be issued on all goods returned for credit. Only standard, currently
manufactured ROHN products may be considered for return and credit. Unsaleable
products will be scrapped and no credit will be received. If returned goods are
determined to have no value and Buyer wishes them returned, the Buyer will be charged
return freight. Safety equipment, erection equipment, insulators, transformers, nuts and
bolts are not returnable.
8. ROHN warrants the commercial items of its manufacture only, to be reasonably fit for
the purpose for which they are manufactured and sold, provided, however, that this
warranty shall be effective only if purchaser installs all material according to ROHN's
recommendations and specifications and that purchaser during the warranty period shall
regularly, not less than semi-annually, inspect and properly maintain all items. Any item
found unfit for its purpose within 12 months from date of delivery will be repaired or
replaced free of charge, F.O.B. ROHN's plant. ROHN shall be immediately notified in
writing of such unfitness. ROHN reserves the sole right to determine if any material is to
be repaired or replaced free of charge or to be supplied at ROHN's standard prices. Such
obligation shall be limited to parts returned for inspection, properly packed and expenses
prepaid, and providing inspection shall satisfactorily indicate defects. The warranty
herein made is in lieu of all other warranties and, except as expressly stated herein,
ROHN does not make and there are no warranties or obligations of any kind or nature
whatsoever either expressed or implied including, but not restricted to, warranty or
obligations as to product, material, workmanship, or manufacture or as to the use of the
items covered hereby. ROHN shall not under any circumstances be liable to third
persons for any claims for damages including direct, special, indirect, or consequential
damages for any reason. The Buyer agrees to indemnify and to hold ROHN harmless for,
of, and from any loss, claims, damages, expenses and attorneys fees, including but not
limited to, any fines, penalties and corrective measures ROHN may sustain by reason of
Buyers failure to comply with said laws, rules, and regulations in connection with the
performance of this sale. The above warranty warranted applies only to items
manufactured by ROHN. Items not manufactured by ROHN are guaranteed only to the
extent and in the manner warranted and guaranteed to ROHN by the manufacturer of
such items and then only to the extent ROHN is liable to enforce such warranty or
guarantee. ROHN will assume no responsibility for the adequacy of any product if
material is used which is not totally supplied by ROHN. The above sets forth the only
warranty made by ROHN in connection with items manufactured or sold by it, and any
provisions in any proposals, specifications, advertising, or other provisions hereof, are
merely descriptive and are not to be construed as warranties made by ROHN. All
warranties are void on drawings made by others, whether by a professional engineer,
sealed or not, that are not rechecked by ROHN and approved by ROHN. ROHN assumes
no liability for the adequacy of the drawings or the product. Without limiting the
generality of the foregoing, the Buyer hereby indemnifies ROHN and hold ROHN
harmless from any and all claims and/or damages (including direct, special, indirect or
consequential damages, attorneys fees and costs) relating to or arising out of any
highway structure or component not designed by ROHN. ROHN hereby disclaims any
and all warranties, including express or implied warranties of merchantability and
fitness for any particular purpose, relating to or arising out of metal fatigue.
9. ROHN reserves the right to change or modify the product and construction of any
product manufactured by ROHN and to substitute material equal to or superior to that
originally specified.
10. Buyer agrees not to disclose or make available to any third party processes,
drawings, specifications, reports, photographs, data and other technical or proprietary
information relating to ROHN products without obtaining prior written consent of ROHN.
11. No proposal, order, quotation, or acceptance may be changed or varied by verbal
agreement, and all orders are accepted only under the provisions set forth herein.
12. Purchase orders and requests for quotations must be submitted in writing to ROHN.
It is the responsibility of the Buyer or Buyer Representative to provide ROHN design
criteria (environmental loads, equipment loads, operational limitations, geotechnical
information, etc.) based on site-specific data. In designing the product for the Buyer,
ROHN is relying solely and entirely on design criteria provided by the Buyer to ROHN.
Without limiting the generality of the indemnities in these Terms & Conditions, the Buyer
hereby indemnifies ROHN and holds ROHN harmless from and against any and all claims
and/or damages (including direct, special, indirect or consequential damages, attorneys
fees and costs) relating to or arising out of any inaccuracy or incompleteness in design
criteria provided to ROHN by the Buyer, and the Buyer waives all claims against ROHN
for same.
13. If outside source inspection, assembly, etc. is required prior to shipment of an order,
$50.00 per man hour (plus equipment time, if applicable) is chargeable, with $300.00 as
a minimum.
14. Any welding inspection required by Buyer or Buyer's specifications must be done at
ROHN's plant prior to packing and shipment of material from ROHN's plant.
15. A minimum charge of $25.00 will be billed for special handling and preparation of
material for air shipments.
16. ROHN reserves the right to apply all remittances and credit memos to the oldest
outstanding balance in your account. No credits will be issued for any reason against a
purchase order whose billing is more than 90 days old. Buyer corrections or complaints
must be made within this period of time.
17. Standard catalog prices do not include special drawings or product evaluations. If
any are required, there will be a charge.
18. ROHN at all times reserves the right to take pictures of any or all of its products after
installation for advertising purposes, except those which are under classified
governmental control.
19. The Buyer will be responsible for any extra charges incurred on prepaid shipments.
20. A service charge not to exceed 2% per month or maximum allowable per State law
will be billed on all accounts not paid within 30 days of invoice date.
21. Minimum total net worth of merchandise which can be ordered is $100.00. Any
orders placed for less will be billed at $100.00.
22. Storage charges will be .02% of invoice amount per day with a minimum charge of
$8.00 a day. These charges will be invoiced on a monthly basis for material requested
to be withheld from shipment starting 30 days from the initial notification from ROHN,
that the material was available for shipment.
23. All CIA requirements must be met with certified checks or money orders to insure
prompt shipment.
24. All expenses incurred by ROHN during any collection effort shall be charged to the
Buyer.
25. There will be a minimum of a $100 fee per truck or container, for ROHN to receive,
handle and pack for reshipment, any material not purchased through ROHN, but drop
shipped to ROHN for shipment with a ROHN structure. This includes light kits,
platforms, mounts, rigging equipment, etc. that is provided by others. There will be a
minimum $250 per truck or container for those drop shipped items that must be handled
with ROHN forklifts or other mechanical device.

Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
318
NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
319
2011 ROHN PRODUCTS LLC

NOT E S
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
I NF OR MAT I ON
320
2011 ROHN PRODUCTS LLC
I
The information contained in this catalog does not purport to cover all details or variations in
equipment nor provide for every possible contingency to be met in connection with installation,
operation or maintenance. ROHN assumes no obligation to revise any of the information contained
in this catalog if changes are made in criteria or evaluation techniques at a later date. Should
particular situations arise which are not covered sufciently herein for the purchasers purposes,
the matter should be deferred to ROHN.
All towers, poles and masts must be installed and dismantled by experienced and trained personnel.
All installations must be thoroughly inspected by qualifed personnel and remarked as required with hazard
and warning labels at least twice a year to ensure safety and proper performance.
All installations must be grounded per local and national codes.
The mixing of so-called interchangeable copies of ROHN products is dangerous and voids all data
or warranty supplied by ROHN. Materials used by others are not the same quality and have not been
tested or checked by ROHN to conform to the same quality standards. Mixing of non-ROHN items may
endanger lives and cause serious failures and fnancial misfortune for all concerned.
Manufacturing Locations:
6718 W. Plank Road
Peoria, IL 61604
#1 Fairholm Avenue
Peoria, IL 61603
Mailing Address:
PO Box 5999
Peoria, IL 61601-5999
Phone:
(309) 566-3000
(800) 727-ROHN (7646)
Fax:
(309) 566-3079
Web:
www.rohnnet.com