60 Series Ball Valves 5

Testing
Plastic-Seated Valves
Every 60 series ball valve is factory
tested with nitrogen at 1000 psig (69 bar)
or its maximum working pressure if
less than 1000 psig (69 bar). Seats
have a maximum allowable leak rate of
0.1stdcm
3
/min, lower than allowable in
FCI 70-2 Specifcation Class VI.
Shell testing with nitrogen at 1000 psig
(69 bar) or the maximum rated pressure if
less than 1000 psig (69 bar) is performed
to a requirement of no detectable
leakage with a liquid leak detector.
Shell testing at 1.5 times the maximum
working pressure is performed on CE-
marked 67 and 68 series valves.
Special-Application Valves
Certain valves may have different
testing requirements, as described in
Special-Application Valves.
Cleaning and Packaging
Every 60 series ball valve is cleaned in
accordance with Swagelok Standard
Cleaning and Packaging (SC-10),
MS-06-62. Cleaning and packaging
in accordance with Swagelok Special
Cleaning and Packaging (SC-11),
MS-06-63, to ensure compliance with
product cleanliness requirements
stated in ASTM G93 Level C is available.
Contact your authorized Swagelok
representative for more information.
Metal-Seated Valves and
3-Way PEEK-Seated Valves
Every 60 series ball valve is factory
tested with nitrogen at 50 psig (3.4 bar)
for leak-tight integrity of the seats as
specifed by FCI 70-2 Specifcation
Class VI.
Shell testing with nitrogen at 1000 psig
(69 bar) or the maximum rated pressure if
less than 1000 psig (69 bar) is performed
to a requirement of no detectable
leakage with a liquid leak detector.
Shell testing at 1.5 times the maximum
working pressure is performed on
CE-marked, stainless steel 67 and
68 series valves.