ID # Description Input Voltage FLA KVA Notes:

ANTENNA CONTROL SYSTEM


RACK MOUNTED EQUIPMENT
A1 Antenna Control Unit (ACU); 7200 ACU 230VAC, 1Phase, 50Hz, 2-wire+G 0.33 0.08 Customer supplied power.
A2 VertexRSI Tracking Receiver; DTR 230VAC, 1Phase, 50Hz, 2-wire+G 0.22 0.05 Customer supplied power.
ANTENNA EQUIPMENT
A3 Antenna Drive Unit (ADU); 7150 ADU 400VAC, 3Phase, 50Hz, 4-wire+G 10.36 7.18 Customer supplied power to terminate at 20 Amp circuit
Controller 0.29 0.20 breaker in ADU.
Azimuth Drive Motor 3Hp 400VAC, 3Phase, 50Hz 4.90 For reference onlyPower supplied via A3.
Elevation Drive Motor 3Hp 400VAC, 3Phase, 50Hz 4.90 For reference onlyPower supplied via A3.
Polarization Drive Motor SS-252B 230VAC, 1Phase, 50Hz 0.83 For reference onlyPower supplied via A3.
ANTENNA ANTI-ICE SYSTEM
RACK MOUNTED EQUIPMENT
D1 VertexRSI 1230 Anti-Ice Controller 230VAC, 1Phase, 50Hz, 2-wire+G 0.87 0.20 Customer supplied power.
ANTENNA EQUIPMENT
D2 VertexRSI 1230 Power Control Unit (PCU) 400VAC, 3Phase, 50Hz, 4-wire+G 38.97 27.00 Customer supplied power to terminate at 50 Amp circuit
Controller 0.29 0.20 breaker in PCU.
Reflector Heaters Qty. 11 230VAC, 1Phase, 50Hz 4.57 1.05 For reference onlyPower supplied via D2.
Qty. 9 230VAC, 1Phase, 50Hz 6.74 1.55 For reference onlyPower supplied via D2.
Feed Heater 230VAC, 1Phase, 50Hz 2.27 0.52 For reference onlyPower supplied via D2.
SubReflector Heater 230VAC, 1Phase, 50Hz 3.37 0.78 For reference onlyPower supplied via D2.
ANTENNA UTILITY SYSTEM
ANTENNA EQUIPMENT
U1 Utility Power Feeder 230VAC, 1Phase, 50Hz, 2-wire+G 16.41 3.77 Customer to supply utility circuit breaker of 25 Amps minimum.
Qty. Power (W)
Feed Rainblower System 1 2015 230VAC, 1Phase, 50Hz, 2-wire+G 8.76 2.02 For reference onlyPower supplied via U1.
Environmental Hub Heaters 1 965 230VAC, 1Phase, 50Hz, 2-wire+G 4.20 0.97 For reference onlyPower supplied via U1.
Environmental Hub Fan 1 30 230VAC, 1Phase, 50Hz, 2-wire+G 0.13 0.03 For reference onlyPower supplied via U1.
Environmental Hub Light 1 100 230VAC, 1Phase, 50Hz, 2-wire+G 0.43 0.10 For reference onlyPower supplied via U1.
Environmental Hub Socket 1 200 230VAC, 1Phase, 50Hz, 2-wire+G 0.87 0.20 For reference onlyPower supplied via U1.
Aircraft Warning Lights 4 116 230VAC, 1Phase, 50Hz, 2-wire+G 2.02 0.46 For reference onlyPower supplied via U1.


U2 Technical Power Feeder (UPS) 230VAC, 1Phase, 50Hz, 2-wire+G 0.87 0.20 Customer to supply utility circuit breaker of 10-15 Amps.
Qty. Watts
Environmental Hub Tech Socket 1 200 230VAC, 1Phase, 50Hz, 2-wire+G 0.87 0.20 For reference onlyPower supplied via U2.
VertexRSI Antenna Products Division Kilgore, Texas Facility
2600 N. Longview St., Kilgore, Texas USA 75662 PR 6.3M HW C-BAND rev A
Power Requirements
VertexRSI MODEL # 6KPC
VertexRSI Contract # 6.3M HW C-BAND

You might also like