Import Text File Format Description
The import file must be in text file format. The cel file is a tab-delimited
text file which contains following information:

1
st
row - Cel file header. This row is optional
2
nd
row - Field titles separated by tab character
3
rd
row onward [Field values separated by tab character

The title row must contain the following fields in any order:

Field Names Description
CELL Cell Name.
UARFCN UARFCN (WCDMA only).
SC Scrambling Code (WCDMA only)
ARFCN BCCH (GSM only).
BSIC BSIC (GSM only)
LAT Latitude in decimal format e.g.
30.1232422
LON Longitude in decimal format e.g. -
101.23242
ANT_ORIENTATION
or ANT_DIRECTION
Antenna direction in degree (Range 0 to
360)
ANT_BEAM_WIDTH Antenna beam-width in degree (Range 1 to
360). If empty or zero, default value 60
will be used. This field value is used to set
the angle of the sector [3]. For an omni
cell, set this field to 360 to draw a circle
object.
ANT_HEIGHT Antenna height in meters. If empty or zero,
default value 100m will be used. This field
value is used to set the sector altitude from
the ground [4]





Object Label Description
1. Site Label The site label is made of the cell name without the last
character. Each cell record will have on Site label
however if the preceding cell record belongs to the
same site, no site label will be created.
2. Cell Label Cell label consists of two parts
[Cell suffix] : [Carrier Info]

- Cell suffix is the last character of the cell name
- Carrier Info is SC (for WCDMA cell) or BCCH
[BSIC] (for GSM cell)

The mandatory fields are used to draw the cell object in the GE map
layer. Any additional fields will be shown in the pop-up balloon when
the cell is selected.




Note: Please find the sample cel files in the installation folder
C:\Program Files\aexio\aexio GEConverter\Sample
2
1
3
4


2006-2007 Copyright Aexio Technologies Sdn. Bhd.
A
e
x
i
o

G
E

C
o
n
v
e
r
t
e
r

Q
u
i
c
k

R
e
f
e
r
e
n
c
e

G
u
i
d
e

For updates and help, please join the user community at http:\\www.aexiocommunity.com

Applying Themes

GE Converter allows user to specify themes for a specified field in
the import file. For example, the cel file has a field/column name
SITE_STATUS where each cell can either has On Air or
Planned value. You can set different color and sector radius for
each of the site status. Follow the steps below to the apply themes
in the GE Converter.

1. At the GE Converter Dialog, click the Themes.. button in
the settings section.
2. In the ThemeSetting dialog, enter the FieldName of the
columns where you want to apply the theme



3. Click on the Collection button to enter individual theme.
4. Click the Add button to insert a new individual theme
5. At the properties list box, enter the value of the theme e.g.
On Air and set the Theme Color and sector radious for
the theme.





6. Repeat step 4 & 5 for the Planned theme



2. Enter Field Name
3. Click the collection
button to enter
individual theme
4. Click Add to insert a
new individual theme
5. Enter the
properties of the
theme
Planned Cell