To find list of sites whose DIP is in ABL state dtstp:dip=all,state=abl;
dtstp:digital path state print To check quality of dip dtqup:dip=dip name; dtqup:digital path quality print To refresh errors in DIP dtqsr:dip=dip name,unacc,degr,sf; dtqsr:digital path quality supervision reset unacc:All parameters of unacceptable performance level is reset(ES,SES,DM) DEGR:all parameters of degraded performance level is reset To see status of all DIP dtqup:dip=all; To change the name of DIP dtpnc:dip=dip name,new dip=new dip name; dtpnc:digital path name change cell=cell designation which can have maximum of 7 characters To deblock a particular DIP dtble:dip=dip name; dtble:digital path transmission functioning blocking end To find cell status rlcrp:cell=all; rlcrp:radio controlled cell resources print To find if a particular cell has a got TS blockage SDCCH+CBCH=X Divide X/8 and ADD this to BCCH and NOOFTCH if this is equal to 32(For 4 tru) then there is no blockage or else there is a blockage Why 32:Because in 1 TRU there are 8 TS to find external alarms allip:alcat=ext; to find level 1& 2 alarms allip:acl=a1; allip:acl=a2; allip:alarm functions alarm list print alcat:alarm category to find TG Value rxtcp:moty=rxotg,cell=name; rxtcp:radio x-ceiver administration TG to channel group deblocking the tru <rxbli:mo=rxotrx-3-5,subord,force; To make TRU out of service rxese:mo=rxotrx-42-0,subord; To make TRU in service rxesi:mo=rxotrx-42-0,subord; To find the status of CF of a particular site rxmsp:mo=rxocf-TG Value; blocking the dxu rxbli:mo=rxotg-16,subord,force; To make DXU out of service rxese:mo=rxotg-16,subord; TO make DXU in service rxesi:mo=rxotg-16,subord; Deblocking the DXU rxble:mo=rxotg-16,subord; To block deblock CF rxbli:mo=rxocf-TG Value; To block a particular TS rxbli:mo=rxots-53-1-1; To deblock a particular TS rxble:mo=rxots-53-1-1; To find CF fault codes rxmfp:mo=rxocf-502,faulty; To find all fault codes CF and TRX faults rxmfp:mo=rxotg-23,subord,faulty; To find all the CF Fault affected sites rxasp:moty=rxocf ; rxasp:radio x ceiver administration managed object alarm status print To find if a particular TRU is in local mode rxasp:mo=rxotrx-trx value; rxasp:radio x-ceiver administration managed object alarm situation print To find all fault codes CF and TRX faults rxmfp:mo=rxotg-23,subord,faulty; To hault or activate a paricular cell rlstc:cell=cell name,state=halted,active; rlstc:radio control cell state change To find the list of devices rxapp:mo=rxotg-TG Value; To find MO status rxmsp:mo=rxocf-109,subord; To find status of various TRX in a TG rxmsp:mo=rxotrx-6-7,subord; if the status of TRU are unconfig and site is not halted check may be TRU are wrongly defined and check the tx power of transmitter To find property of TRX rxmop:mo=RXOTrx-406-1; To find software version of a site rxmop:mo=rxotg-TG Value; see last 2 digits of SWVERDLD and SWVERACT to know softaware version To get list of devices attached to TG Value rxapp:mo=rxotg-TG Value; rxapp:radio x-ceiver administration abis path status print To find cabinet type rxmfp:mo=rxocf-TG Value; To find KLM and vc-12 value tpcop:sdip=0etm2; Procedure to find a site is independent radep:dev=RBLT2-2239(From this command find the value of SNTINL RBLT2 is one device of slave side radep:dev=RBLT2-2239(From this command find the value of SNTINL ntcop:snt=etm2-3; Fromt this command the site which has got the same value of SNTINL is the master To find out TEI value of a site and signalling rxmop:mo=rxocf-TG Value; To find the power in a particular TX rxmop:mo=rxotx-TX Value of a site; To find site id through TG Value rxmop:mo=rxotx-402-2; rxasp:mo=rxotrx-TEI Value; To find log of a particular site step1:type F8 to create a log file step2:aploc; alogfind -a starttime -e startdate(year/month/day) -b closetime -g closedate close log file To test a particular managed object rxtei:mo=mo value(rxotrx,rxorx,rxorx,rxots) rxtei:radio x-ceiver administration test of mo initiate rxtee:mo=mo value(rxotrx,rxorx,rxorx,rxots) To find overall status of a site rxcdp:mo=rxotg-TG Value; rxcdp:radio x ceiver administaration m/o configuration data To find information about m/o device rxmdp:mo= THIS COMMAND IS VALID FOR CF,DP,TRXC,TS rxmdp:mo=rxocf-125; To make UNCONFIG TS CONFIG provided the rxbli:mo=rxotg-16,subord,force; cell is not halted rxese:mo=rxotg-16,subord; To load a paricular site rxesi:mo=rxotg-16,subord; both things can be done at the same time rxble:mo=rxotg-16,subord; To change tx power of trx rxmoc:mo=rxotrx-TEI VALUE,mpwr=power; rxmoc:radio x-ceiver administration m/o object data change To define a new DIP NTCOP:snt=etm2-3; etm value in which that dip needs to be created ntcop:switching network terminal connection data,print tpcop:sdip=0etm2; TPCOP:transmission function synchronous digital path connection data print dtdii:dip=dipname,snt=etm2-3,dipp=x; x-value corresponding to vc-12 for that particular KLM tpble:sdip=3etm2,lp=vc12-8; tpble:transmission func synchronous digital path,blocking end sdip:synchronous digital path lp:lower order path dtble:dip=dip name; dtble:digital path func blocking end To remove TS having LOOP TEST FAILED rxbli:mo=rxots-53-1-1; rxble:mo=rxots-53-1-1; rlncp:radio controlled cell neighbour to cell print To find status of link for aparticular BSC c7ltp:ls=all; ls:link set To find out put pwer of a particular cell rlcpp:cell=cell name; rlcpp:radio controlled cell configuration data print mstxpwr:bspwrb Base Station (BS) output power in dBm, for Broadcast Control Channel (BCCH) Radio Frequency (RF) channel number. The current Base Transceiver Station (BTS) version may have specific parameter restrictions. See "BTS parameter limitations" in OPERATION AND MAINTENANCE MANUAL for current BTS version. This parameter is not valid for external cell.
bspwrt Base Station output power in dBm, for the non-BCCH RF channel numbers. cell Cell designation mstxpwr Maximum transmit power for the Mobile Station (MS) on connection. sctype Subcell type. UL Underlaid subcell OL Overlaid subcell. To print DTX downlink data for a cell rlcxp:cell=cell name; rlcxp:radio control cell config. DTX dowlink print dtxd Discontinues downlink transmission. ON Discontinues downlink transmission is enabled in the BSC for the cell. OFF Discontinues downlink transmission is disabled in the BSC for the cell. To deblock a DIP whose SDIP Layer is manually blockeddtdip:dip=dip name; note etm value and dipport(dipp value) tpble:sdip=4etm2,lp=vc12-dippvalue dtble:dip=dip name; dtstp:dip=dip name; TRX status rxcdp:mo=rxotg-tgvalue dfel5186 qwerty@123 if the status of TRU are unconfig and site is not halted check may be TRU are wrongly defined 1 2 3 4 5 TEI Terminal end point identifier To delete a device to check the state of the device to check etm no To check TG value blodi:dev=RTLTT2-4608&&-4639; stdep:dev=RTLTT2-4608&&-4639; dtdip:dip=dip name; ntcop:snt=etm4-2; rxmdp:dev= RBLT2-7809,moty=rxots;